Está en la página 1de 1

10-0210: Gray/Binary Code Converter for ARL-500

Feautures:
- Can be used in ARL-500 lift system in order to drive gray or binary code position indicators
•• Provides up direction, down direction, overload, out of service signals and 6 code outputs for car positioning (up to 48 stops)
- Code type (gray or binary), polarity (inverted and non-inverted) and counting initial (0 or 1) can be adjusted by dip-switches

Dip-switch configuration:
No Position Setting
1 OFF Gray code
ON Binary code
2 ~ 1
OFF Non-inverted code 1 2 3 45 6 7 8
ON Inverted code Dip-switch
OFF Counting initial 0
ON Counting initial 1
4-8 OFF Dip-switches 4, 5, 6, 7 and 8 must be OFF

Connection:
LU

C A N b u s Device CANbus Position


X - C B 2 / r~ X-CB2 /
( R E V K O N / K A B K O N / KK-x)
X-CB1 L
-/
]
L J X-CB1
IO-0210
indicator

Programmable outputs:
Terminal name Description Note
1000 G N D (Common of output signals) OV
01 Code bit 1 (LSB) High level: ~24Vdc, max 100mA
02 Code bit 2 overload & short-circuit protected
03 Code bit 3
04 Code bit 4
05 Code bit 5
06 Code bit 6
07 Down direction
08 Up direction
09 Overload
10 Out of service
1000 G N D (Common of output signals) OV
1000
Note: Input terminals PI-01, Pl-02do not function.

Dimensions: 4,5 4.5

10

6,5
6 6- 7
o mmmmm

77
....... 45

o 7
Q ~R 2,00 IO-0210v).m
o -
6,5

All dimensions are in mm


Min. board depth: 22 mm
100

También podría gustarte