MONITORING RELAYS

These relays are best suitable for monitoring


balanced or unbalanced supplies, either of single
phase, 3-phase 3-wire or 3-phase 4 wire loads
powered by generators, UPS, stabilizers, inverters,
or Mains (by Electricity Boards / Utilities); in AMF
panels, PCCs, distribution boards and for power
monitoring of individual loads / motors / pumps.
MODELS
D1 VCR1,
VCT D2, VCF D2, D2 VCT1, D1 VCT1,
S2 VMR 4, S2 VMR 5,
D2 EFR1, CCSD2, OCS D1,
S2 CMR2, S2 CMR3, S2 CMR4,
OFS D1, S2 FMR1,
RPT D2, RPF D2,
F3 VSR1, F3 VSR2

FEATURES PROTECTIONS / FUNCTIONS


• Fixed/adjustable under/Over trip • Under/over Voltage,
settings for parameters. • Under/Over Current
• Fixed/adjustable trip delays and Power • Under/Over Frequency
On delays • Reverse Power
• Built-in or external power supply • Earth Fault/Ground Fault
• Resetting – Auto or Manual • Earth leakage
• Output contacts : 1 CO or 2 CO
• Choice of enclosures (DIN-Rail, Flush)
• Models with Micro-Controller based
design
• 2 line alpha-numeric LCD display (for
F3 VSR1/2)
• Serial Communication (RS232) port Ordering Instructions
(for F3 VSR1/2 models)
• Use of SMD Technology ü Product Family Name
• User-friendly LED indications ü Model Name
ü System Supply Voltage
& frequency
ü Aux. Supply/Control
supply voltage
ü Current input (1A or 5A)

15
VOLTAGE MONITORING RELAYS
D1 VCR 1 VCT D2 VCF D2
1 Phase Voltage Voltage Monitoring Voltage Monitoring
Monitoring Relay Relay, 3Ø-3W Relay, 3Ø-4W

Single Phase Under & 3-Phase 3-Wire Under 3-Phase 4-Wire Under
Over voltage, Auto Reset, & Over voltage & Over voltage
Adjustable under / over Auto/Manual Reset, Auto/Manual Reset,
voltage settings, 2 CO Adjustable under/over Adjustable under/over
output relay. voltage settings, voltage settings,
adjustable trip delay & adjustable trip delay &
ON delay, ON delay,
2 CO output relay 2 CO output relay

System Supply 220/230/240 V AC (+ 20% - 30%), 50/60 Hz ± 110/240/380/415/440 V AC +20%, – 25% 50/60Hz
Output Relay Contact 2 CO 2 CO 2 CO
Trip Setting
Under Voltage 75 - 95% [Variable] of set value 75% - 95% (adjustable) 75% - 95% (adjustable)

Over Voltage 105 - 120% [Variable] of set value 105% -120% (adjustable) 105% -120% (adjustable)

Trip Time Delay 2- 5 Sec (Fixed) (UV/OV) 1-10 secs. (adjustable) 1-10 secs. (adjustable)
Power on Delay 1-10 secs. (adjustable) 1-10 secs. (adjustable)
Reset Auto Reset Auto / Manual Auto / Manual
Weight 180 gms. 450 gms. 450 gms.
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 76 x 56.5 x 117.5 76 x 56.5 x 117.5
Mounting 68 mm centre to centre / 35 mm rail 67 x 46 / 35 mm rail 67 x 46 / 35 mm rail
mounting mounting mounting

• Wherever not specified


Contact Rating :
OV SET
5A @ 230 V AC OV SET OV RESET
(resistive) 1 Ph N
OV RESET
3 Ph

UV RESET UV RESET
UV SET UV SET
TD
TD 2 to 5sec. TD 1 to 10sec. TD

13 14 1 2
T on
13 14 16 17 1 to 10sec.

13 15 1 3
13 15 16 18

L L
O L R
L
A R
N D O Y O
Y A A
B
D
OFF ON B D
N
OFF
OFF
D1 VCR1
N/V
1 2 3
ON ON
N/V
N/V
1 2 3 4 5 6 1 2 3 4 5 6

VCT D2 VCF D2
D1 VCR1 A/M A/M
LINK LINK

7 8 9 10 11 12 7 8 9 10 11 12
7 8 9

13 14 151617 18
13 14 151617 18
13 14 15

Relay contact position shown in 'Power off' condition

16
VOLTAGE MONITORING RELAYS
D1 VCT1 D2 VCT1 S2 VMR4 S2 VMR5
Voltage Monitoring Voltage Monitoring Voltage Monitoring Voltage Monitoring
Relay, 3Ø-3W Relay Relay, 3Ø-3W Relay, 3Ø-4W

R R R

C US C US C US

3-Phase 3-Wire Under 3-Phase 3-Wire and 3-Phase 3-Phase 3-Wire Under & Over 3-Phase 4-Wire Under & Over
& Over Voltage, 4-Wire (selectable) Under & Over voltage, Microcontroller based voltage, Microcontroller based
Auto reset, voltage, Microcontroller based design, SMD Technology design, SMD Technology, Auto /
design, Auto/Manual Reset, Auto/Manual Reset, , Adjustable Manual Reset, Adjustable
Adjustable UV/OV Adjustable under/over voltage under/over voltage settings, under/over voltage settings,
settings, settings, Absolute values for Absolute values for UV/OV, Absolute values for UV/OV,
fixed trip delay, UV/OV, adjustable trip delay & adjustable trip delay & ON delay, adjustable trip delay & ON delay,
2 CO output relay. ON delay, 2 CO output relay (or 2 CO output relay (or selectable 2 CO output relay (or selectable
selectable 1CO for UV, 1CO for OV) 1CO for UV, 1CO for OV) 1CO for UV, 1CO for OV)
Failsafe-non-failsafe selectable Failsafe-non-failsafe selectable Failsafe-non-failsafe selectable

100-120/220-240/380-440 V AC 100-120/220-240/380-440V AC -25%+20%,48-63 Hz 100-120/220-240/380-440V AC -25%+20%,48-63 Hz 100-120/220-240/380-440V AC -25%+20%,48-63 Hz


2 CO 1 CO + 1 CO / 2 CO 1 CO + 1 CO / 2 CO 1 CO + 1 CO / 2 CO
Ph Ph Setting:
For 380-440V AC 285-425V AC (Variable) 285 - 425V AC (Variable)
75-115 Unit of 100-120 V AC
For 220-240V AC 165-225V AC (Variable) 165-225V AC (Variable)
165-225 Unit of 220-240 V AC For 100-120V AC 75-115V AC (Variable) 75-115V AC (Variable)
285-425 Unit of 380-440 V AC Ph N Sensing:
For 380-440V AC 165-245V AC (Variable) 165-245V AC (Variable)
For 220-240V AC 95-135V AC (Variable) 95-135V AC (Variable)
For 100-120V AC 45-65V AC (Variable) 45-65V AC (Variable)
Ph Ph Sensing:
105-145 Unit of 100-120 V AC For 380-440V AC 400-520V AC (Variable) 400-520V AC (Variable)
230-290 Unit of 220-240 V AC For 220-240V AC 230-290V AC (Variable) 230-290V AC (Variable)
400-520 Unit of 380-440 V AC For 100-120V AC 105-145V AC (Variable) 105-145V AC (Variable)
Ph N Sensing:
For 380-440V AC 230-310V AC (Variable) 230-310V AC (Variable)
For 220-240V AC 130-170V AC (Variable) 130-170V AC (Variable)
For 100-120V AC 60-80V AC (Variable) 60-80V AC (Variable)

3.5±1.5 Sec (UV/OV) 1-10 Sec (Variable) UV/OV/NF 1-10 Sec. (Variable) 1-10 Sec. (Variable)
1-10 Sec (Variable) 1 10 Sec (Variable) 1 10 Sec (Variable)
Auto Reset Auto/ Manual Reset Auto / Manual Reset Auto / Manual Reset
200 gms. (Approx). 300 gms (Approx.) 110 gms (Approx.) 110 gms (Approx.)

76 x 30.5 x 117.5 76 X 56.5 X 117.5 90 X 35 X 60 90 X 35 X 60


68 centre to centre / 35 mm rail 67 x 46 / 35 mm rail mounting 35 mm Rail Mounting 35 mm Rail Mounting
mounting

OV SET
OV SET OV SET OV SET OV RESET
OV RESET OV RESET OV RESET
3 Ph N
3 Ph UV RESET 3 Ph N 3 Ph
UV SET
UV RESET
UV RESET UV RESET UV SET
UV SET UV SET TD
TD TD TD TD 1 to 10sec. TD
3.5 sec. 1 to 10sec. TD 1 to 10sec. TD

T on T on T on
13 14 16 17 1 to 10sec. 7 8 10 11 1 to 10sec. 7 8 10 11 1 to 10sec.
13 14 1 2

13 15 1 3 13 15 16 18 7 9 10 12 7 9 10 12

L
R R
L
O
O
A Y Y
A
D N
D
B B
N
3 or 4 Wire
selection link

OFF

DOL STARTER
D2 VCT1

Relay position shown in ‘Power off’ condition

17
CURRENT MONITORING RELAYS
OCS D1 S2 CMR2
1 Phase Over Current Relay 1 Phase Current Monitoring Relay

C US

Single phase over current Auto reset, Single phase under & over current
Input 1A or 5 A through CT, Microcontroller based design, SMD technology,
Adjustable over current trip settings, Auto/Manual reset, Input 1A or 5 A through CT,
Adjustable trip delay, Adjustable under / over current trip settings,
1 CO output relay adjustable trip delay & ON delay,
2 CO output relay (or selectable 1CO for UC,
1CO for OC)
Failsafe-non-failsafe mode selectable

Supply Voltage
System 110-120/220-240/380-440 V Ac±20%, 100-120 / 220-240 V AC ±20%,
Auxiliary 12 V DC/24/30 V Dc±10% 24 V DC ±10%
Ext. Input 1 Amp or 5 Amp (Secondary) CT 250/500 mA 1 Amp or 5 Amp (Secondary) CT
Output contact 1 CO 1 CO + 1 CO

Trip setting
EF Trip Setting — —

Under Current N.A. 10% - 100% (Variable)

Over Current 50% -140% (adjustable) of CT sec 50% - 140% (Variable)


Power On Delay 3.5 secs ± 1.5 sec (fixed) 1-10 Sec. (Adjustable) ± 1 Sec.
Trip Time Delay 1 - 10 secs (adjustable) 1-10 Sec. (Adjustable) ± 1 Sec.
Resetting Auto Auto / Manual
Weight 250 gms. 140 gms
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 90 X 35 X 60
Mounting (L x W) 68mm centre to centre / 35mm rail Mounting 35 mm Rail Mounting

• Wherever not specified


Contact Rating : Aux. Supply Aux. Supply
5A @ 230 V AC
(resistive) OC SetPoint
OC Reset
OC SetPoint
OC Reset
UC Reset
UC SetPoint

Current Input Current Input


AUTO
RESET
T ON T ON
2 to 5 sec. Td - 1 to 10 sec. Td -
1 to 10 sec. 1 to 10 sec.
13 14 7 8 10 11

13 15 7 9 10 12

L L
O
N A
D

N/V
1 2 3 DOL STARTER
OCS D1
ON OFF

AUX.
SUPPLY
7 8 9

13 14 15

Relay contact position shown in 'Power off' condition

18
GROUND FAULT MONITORING RELAYS
D2 EFR1 S2 CMR3 S2 CMR4
Earth Fault Relay Ground Fault Relay Earth Leakage Relay

R R

C US C US

Earth fault/Ground fault monitoring of Earth fault/Ground fault monitoring of Earth leakage monitoring of 3 phase
3 phase systems 3 phase systems, Microcontroller based systems, Microcontroller based design,
Manual Reset, design, SMD technology, Manual Reset, SMD technology, Manual Reset,
Input 1A or 5A through CBCT, Input 1A or 5A through CBCT, Input through CBCT,
Adjustable earth fault trip setting, Adjustable earth fault trip setting, Adjustable trip setting,
adjustable trip delay, Adjustable trip delay & ON delay, Adjustable trip delay & ON delay,
2 CO relay output 2 CO relay output 2 CO relay output
Failsafe-non-failsafe seletable Failsafe-non-failsafe seletable

24-30 VDC / 100-120 / 220-240 / 380-440 V AC ±20% 100-120/220-240/380-440 V AC ± 20%, 48-63 Hz 100-120/220-240/380-440 V AC ± 20%, 48-63 Hz
100-120/220 -240 V AC / 24V DC ± 20% 100-110/240V AC / 24V DC ± 20%
1A or 5A (Selectable) CBCT
1 CO (2 CO) (Pick up on Fault) 2 CO 2 CO

10% -100% (adjustable) of CT sec 10% - 100% of Rated Current Input (Variable) 10% - 100% of Rated Current Input (Variable)
(Input through CT of 1AMP or 5AMP Secondary) (Input through CBCT of 300m A Secondary)

N.A. N.A. N.A.

N.A. N.A. N.A.


N.A. 1 -10 Sec.(Adjustable) 1 -10 Sec.(Adjustable)
0.1-1.0 / 1-10 Sec. (Adjustable) 0.1 - 1 Sec.(Adjustable) 0.1 Sec to 1 Sec.(Adjustable)
Manual / Remote (Selectable) Manual Manual
550gms. 140 gms 140 gms

76 x 56.5 x 117.5 90 X 35 X 60 90 X 35 X 60
67 x 46 / 35 mm rail Mounting 35 mm Rail Mounting 35 mm Rail Mounting

Td Td

13 14 16 17

13 15 16 18

EXTERNAL CBCT(ZCT)
5 Amp. CT. CBCT ( ZCT)

R Ø R
Y Ø M
MOTOR
Y M
B
B Ø
OFF ON
OFF ON N/V
N/V

1 2 3 4 5 6
AUX.
SUPPLY
S2 CMR 4
D2 EFR1 *Use either *Use either
Ø
Ø 3 x 5A Ext. CT’s 3 x 5A Ext. CT’s
or 3 x 1A Ext. CT’s or 3 x 1A Ext. CT’s 7 8 9 10 11 12

13 14 15 16 17 18 or 1 x 5A (or 1A) CBCT or 1 x 5A (or 1A) CBCT

Relay contact position shown in 'Power off' condition

19
FREQUENCY MONITORING RELAYS
OFS D1 S2 FMR1
Over Frequency Relay Frequency Monitoring Relay

C US

Single phase over frequency, Single phase under & over


Auto reset, frequency, Microcontroller based
Adjustable over frequency trip design, SMD technology, Auto
settings,' reset, Adjustable under/over
Adjustable trip delay, frequency trip settings,
1 CO output relay Adjustable trip delay & ON delay,
2 CO output relay Failsafe-non-
failsafe mode selectable

Supply Voltage
System 100-120 / 220-240 / 380-440 V AC ±20% 100-120/220-240/380-440 V AC ± 20%, 38-72 Hz
Auxiliary 12 / 24 V DC or Built in In Built
Ext. Input —
Output contact 1 CO 1 CO + 1 CO
Trip setting
Under Frequency N.A. 40 Hz - 60 Hz (Variable)
Over Frequency 50 Hz - 70 Hz 50 Hz - 70 Hz (Variable)
Reverse Power — —
Power On Delay 3.5 secs. ± 1.5 sec (fixed) 1 - 10 Sec.(Adjustable) ± 1 Sec.
Trip Time Delay 1 - 10 secs. (adjustable) 1 - 10 Sec.(Adjustable) ± 1 Sec.
Resetting Auto Auto / Manual
Weight 450 gms. 130 gms
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 90 X 35 X 60
Mounting (L x W) 68 centre to centre / 35 mm Rail Mounting 35 mm Rail Mounting

• Wherever not specified Aux. Supply Aux. Supply


Contact Rating :
5A @ 230 V AC OF SetPoint OF SetPoint
OF Reset OF Reset
(resistive)
UF Reset
UF SetPoint

Freq. Input Freq. Input


AUTO
RESET
T ON T ON
2 to 5 sec. Td - 1 to 10 sec. Td
1 to 10 sec. 1 to 10 sec.
13 14 7 8 10 11

13 15 7 9 10 12

L L L
O O
A A
N D D

OFF ON
OFF ON

N/V
DOL STARTER N/V
DOL STARTER

1 2 3

OFS D1

7 8 9

13 14 15

Relay contact position shown in 'Power off' condition

20
POWER MONITORING RELAYS
RPT D2 RPF D2
Reverse Power Relay,(3Ø-3W) Reverse Power Relay,(3Ø-4W)

3-phase 3-wire generators reverse Single phase or 3-phase 4-wire


power monitoring generators reverse power monitoring
Auto/Manual reset, Auto/Manual reset,
Reverse power (current) trip settings Reverse power (current) trip settings
adjustable, adjustable,
ON delay and trip delay adjustable, ON delay and trip delay adjustable,
2 CO output relay 2 CO output relay

100-120 / 280-240 / 380-440 V AC ±20% 100-120 / 280-240 / 380-440 V AC ±20%


Built-in Built-in
5A, CT Secondary & R,Y, B 5A, CT Secondary & B, Neutral
2 CO 2 CO

— —
— —
2% - 20% (adjustable) 2% - 20% (adjustable)
1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable.) 1 - 10 secs. (adjustable)
Auto / Manual Auto / Manual
460 gms. 460 gms.

76 x 56.5 x 117.5 76 x 56.5 x 117.5


67 x 46 / 35 mm Rail Mounting 67 x 46 / 35 mm Rail Mounting

POWER POWER
SOURCE SOURCE

1
ASYN.
MOTOR
2
ASYN.
MOTOR 3 Ph
Supply

RPT D2 / RPF D2 RPT D2 / RPF D2 Increasing Foward Current


Forward Power
Reverse Power Increasing Reverse Current

Recovery
Level
Current Tripping
Level

13 14 16 17
Td 1 to 10 sec.
T ON
13 15 16 18 1 to 10 sec.

ASYN.
LOAD
MOTOR

R
L L
Y
P1 P2
O
A
G O
A
D D
B
S1 S2
External
5 Amp Secondary CT

1 2 3 4 5 6
RPT D2
RPF D2
A/M
7 8 9 10 11 12 LINK

Relay contact position


13 14 15 16 17 18
shown in 'Power off' condition

21
VOLTAGE SCANNERS & CONTROLLERS
F3 VSR1 F3 VSR2
Voltage Scanner 3Ø-3W Voltage Scanner 3Ø-4W

3-Phase 3-Wire voltage monitoring & 3-Phase 4-Wire voltage monitoring &
display, Phase Failure, Unbalance, Phase display, Phase Failure, Unbalance,
Sequence, under voltage, Over Voltage, Phase Sequence, under voltage, Over
Auto / Manual Reset, Voltage, Auto / Manual Reset,
Adjustable unbalance trip setting, Adjustable unbalance trip setting,
Adjustable under/over voltage settings, Adjustable under/over voltage settings,
adjustable trip delay, Adjustable trip delay,
RS232 communication port, RS232 communication port,
2 CO output relay, True RMS Values 2 CO output relay, True RMS Values

Supply voltage
System 380 / 415 V AC (3 Ph - 3 W) 380 / 415 V AC (3 Ph - 4 W)
Auxiliary 90-270 V AC/DC Self Powered (Neutral & any Phase)
Output relay contacts 2 CO & RS 232 (optional) 2 CO & RS 232 (optional)
Trip setting
Phase Sequence Yes Yes
Phase Unbalance 1 - 10 % (Adj.) 1 - 20% (Adj.)
Under Voltage 1 - 80V below nominal voltage 1 - 50V below nominal voltage
Over Voltage 1 - 60V above nominal voltage 1 - 25V above nominal voltage
Trip Time delay 1 - 60 secs. or 1-5 mins select. 1 - 60 secs. or 1-5 mins select.
Reset Manual / Auto Manual / Auto
Display Backlit LCD (16 x 2 character) Backlit LCD (16 x 2 character)
Monitoring Phase to Phase Phase to neutral
Weight 800 gms. 800 gms.
Dimensions (mm)
Overall (L x W x D) 96 x 96 x 130 96 x 96 x 130
Mounting (L x W) 92 x 92 92 x 92

RP, UV / OV and UB Protection override facility provided RP, UV / OV and UB Protection override facility provided

• Wherever not specified RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET

Contact Rating : SP UB>SET RP SP UB>SET RP

5A @ 230 V AC OV SET OV SET


(resistive) RYB RYB
LINE LINE
UV SET UV SET
SP SP
UV UV
t OV t UV t UB/SP t UB/SP UB/SP t OV t UV t UB/SP t UB/SP UB/SP

LED LED

RELAY RELAY
C-NO C-NO

AUX.
SUPPLY

C2 NO2 NC2 C2 NO2 NC2

RS232 RS232

R Y B C1 NO1 NC1 R Y B N C1 NO1 NC1

R R
Y Y
B B
N

Relay contact position shown in 'Power on' (Healthy) condition