Generic FD-410Ex User Manual Issue 1.

Appendix C

FD-410 Ex External Power and Data Connections


(Factory Default Connection Details)

ALWAYS REFER TO THE INSTALLATION GUIDE AS CONNECTIONS MAY DIFFER DUE TO CUSTOMER REQUIREMENTS

Terminal Strip 1 (TS1)

Customer 12 Way
Cable Function Chassis
Core Terminals
1 +ve Incoming DC Supply 1
2 -ve Incoming DC Supply 2
3 Comms IN 3
4 Comms OUT 4
5 Comms 0v 5
6 Fog Alarm 1 Common 6
PLC
Fog Alarm 1 Contact 1 * 7
7 Fog Alarm 1 Contact 2 * 8 Directly to Fog
Fault Alarm Common 9 horn

Fault Alarm Contact 1 ^ 10

Fault Alarm Contact 2 ^ 11

Housing Ground 12

* Dependent upon whether Mode A or I is used. For Pharos Marine & API products Factory
Default is Mode A (Active) with the Fog Alarm contacts Common (TS1-6) & Contact 2 (TS1-
8) normally closed to prevent the fog signal from blasting to character.

Fog Alarm contacts will open either in the presence of fog, if power is interrupted, or a
cable disconnected (Fail-safe Mode)

^ Dependent upon whether Mode A or I is used. For Pharos Marine & API products Factory
Default is Mode A (Active) with the Fault Alarm contacts Common (TS1-9) & Contact 2
(TS1-11) normally closed (fail-safe).

Fault Alarm contacts will open either in the presence of a fault, if power is interrupted, or a
cable disconnected (Fail-safe Mode)

Cable screens may be bonded to ground if required via the cable gland(s) within the
Fog Detector