Está en la página 1de 2

EH 油系统 EH oil system

METTUR 签
序 检查日期 试验结果 DEC 签字 BGR 签字
试验内容 字
号 Inspection Inspection Signing by Signing by
Test Content Signing by
No. date result DEC BGR
METTUR
1 EH 油泵启动允许条件 EH oilpump start permission
1、EH 油箱油位不低 EH oil tank level is normal
2、EH油箱油温高于(20℃)时 EH oil TEM is more than 20℃
3、电气允许条件 no electric fault
2 EH 油泵联锁保护 EH oil pump interlock protection
1、EH 油母管压力低至 9.2MPa(压力开关)报警,并且联动备用油泵
1. EH oil manifold pressure lower to 9.2MPa(switch) alarm, and start
up standby EH oil pump by means of interlock
2、运行 EH 油泵跳闸,备用油泵自动启动
2. Operating EH oil pump tripped, standby oil pump auto pickup
3、EH 油箱油位低于 LL(200mm) ,联跳 EH 油泵
3. Oil level in EH oil tank level LL (200mm), EH oil pump tripped in a
manner of interlock
3 EH 油循环泵 A/BEH oil circulation pump A/B
1、EH 油箱油位低低,保护停 1、 EH oil tank level LL, protection OFF
2、运行 EH 油循环泵停运,联启备用泵
2. Operating EH oil circulation pump shutdown, startup standby
pump in manner of interlock
轴封系统 Shaft seal system
检查日期 试验结果 METTUR 签字 DEC 签字 BGR 签字
序号 试 验 内 容
Inspection Inspection Signing by Signing by Signing by
No. Test Content
date result METTUR DEC BGR
轴封风机 A 自启动 Self start of shaft seal fan A
投联锁且 B 泵事故跳闸
1
Enable interlock, and pump B tripped under emergency
轴加压力>5kpa gland sealing condenser pressure>5kpa
轴封风机 B 自启动 Self start of shaft seal fan B
投联锁且 A 泵事故跳闸
2
Enable interlock, and pump A tripped under emergency
轴加压力>5kpa gland sealing condenser pressure>5kpa
轴封冷却器事故疏水电动门
3
Shaft seal cooler emergency drain electric valve
1、轴封冷却器水位高,联锁开
1. Shaft seal cooler water level high, opened in manner of
interlock
2、轴封冷却器水位正常,联锁关
2. Shaft seal cooler water level normal, closed in manner of
interlock