Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Equipment
V200R003C10
Configuration Guide
Issue 01
Date 2014-01-31
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Purpose
This manual describes configuration of U2000 for ATN.
Related Version
The following table lists the product version related to this document.
Intended Audience
This document is intended for:
l Commissioning Engineer
Symbol Conventions
Symbol Description
Command Conventions
Convention Description
Convention Description
GUI Conventions
Convention Description
Change History
Updates between document issues are cumulative. Therefore, the latest document issue contains
all updates made in previous issues.
Contents
1 Network Deployment
1.1 Overview
This topic describes the deployment task, implementation modes, and applicable scenarios at
the network deployment stage. Network deployment must be complete before service
deployment.
Configu Description
ration
Item
Configuri To create and configure interface IP addresses and logical interfaces (loopback
ng the interfaces and subinterfaces).
interface
Configu Description
ration
Item
The U2000 provides two modes to implement the preceding deployment task.
Context
Network deployment can be implemented using the Plug-and-Play Management or NE Explorer.
If the Plug-and-Play Management is used, the following configurations are optional for NEs that
support automatic NE configuration. In other cases, the following configurations are mandatory.
The topology creation procedure varies according to the usage scenario and habit. If a large
number of NEs need to be created in a scenario such as deployment, the topology creation
procedure shown in Table 1-3 is recommended.
Operation Description
Create a subnet. To facilitate management, you can put topological objects that are in
the same area of a network or with similar attributes to the same
topology subnet.
Create NEs in Every physical device is displayed as an NE on the U2000. To use the
batches. U2000 to manage these devices, you must create the relevant NEs on
the U2000. If a large number of NEs need to be created in a scenario
such as deployment, creating NEs in batches is recommended.
NOTE
l When creating NEs in batches, you can use SNMP and Telnet/STelnet
templates to automatically apply the parameter settings.
l Using SNMPv3 is recommended because of its higher security than
SNMPv1 and SNMPv2c.
l Using STelnet is recommended because of its higher security than Telnet.
Select an NE layout. The U2000 provides various NE layouts in order to vividly show the
actual network topology.
Create links. The communication between the U2000 and managed NEs and
between these NEs is implemented based on links. You can configure
services or manage NEs only after creating the associated links in the
topology view.
Prerequisites
l The U2000 communicates with NEs successfully. That is, correct IP addresses are
configured for NEs and the U2000 and managed NEs can ping each other.
l Before automatic ICMP NE searches, disable ICMP packet blocking in the firewall of the
U2000 server, because the ICMP packet blocking interrupts communication between the
U2000 and ICMP NEs.
l Interworking between NEs to be managed and the U2000 has been commissioned. Telnet/
STelnet, SNMP, and NetConf parameters have been set.
Procedure
1. Create a subnet.
a. Right-click in the Main Topology and choose Create > Subnet from the shortcut
menu.
b. In the dialog box that is displayed, select Property and set Name for the subnet to be
created.
NOTE
For example, set Name to IPRAN.
c. Click OK.
2. Create NEs in batches.
a. Choose File > Discovery > NE from the main menu.
b. Click ... on the right of the NE Type text box. In the dialog box that is displayed,
specify the desired NE type.
c. Click Default SNMP Parameter. In the dialog box that is displayed, set SNMP
parameters and ensure that the parameters are consistent with those on the NE side.
a. Click the tab associated with the desired SNMP version. Then click Add.
b. Set Template Name and other parameters as needed.
NOTE
d. Click OK.
d. Optional:
Set Ping Times, Timeout, and Layers as needed.
NOTE
If many NEs need to be searched on the network, setting Ping Times to 3 and Timeout to 5 is
recommended. Otherwise, some NEs may fail to be searched out.
e. Optional:
(Optional) If an SNMP version is not required, select the desired version in
Version, right-click, and choose Delete from the shortcut menu.
NOTE
Deleting the SNMP version that is not required improves NE search efficiency.
f. Select Automatically Create NEs.
g. Click Advanced and set Telnet/STelnet or NetConf parameters for NEs. Using
STelnet is recommended because of its higher security than Telnet.
a. Click ... on the right of Telnet/STelnet Settings. In the dialog box that is
displayed, configure a Telnet/STelnet parameter template with the parameter
values consistent with those on NEs. Telnet/STelnet parameter settings in the
template are automatically applied to created NEs.
1) Click Create.
2) In the dialog box that is displayed, set Protocol Name and Template
Name.
3) Click OK.
4) Select the newly created template. In the Details area, set the relevant
parameters and click Apply.
NOTE
If the AAA user needs to be used, set Auth. Mode to User Auth. In addition, set
User Name and Password.
b. Optional: Click the ... button on the right of NetConf Settings. In the dialog box
that is displayed, configure a NetConf parameter template with the parameter
values consistent with those on NEs. NetConf parameter settings in the template
are automatically applied to created NEs.
NOTE
NetConf parameters need to be set only when VRP V8-based routers are to be created.
1) Click Create.
2) In the dialog box that is displayed, set Template Name.
3) Click OK.
4) Select the newly created template. In the Details area, set the relevant
parameters and click Apply.
c. Click OK.
h. Check whether xFTP service status is normal: Choose Administration > Settings >
xFtpWatcher from the main menu to check whether configuration items in the list
are marked green. If the xFTP service status is abnormal or not configured, configure
the xFTP service by performing operations described in Configure a xFTP
watcher in the follow-up procedure section.
i. Click ... on the right of the Physical Path text box. Then select the created IPRAN
subnet.
j. In the IP Address Range area, click Add. In the dialog box that is displayed, set start
IP address, end IP address and a mask as need and click OK.
k. Click Next. The U2000 begins to search for NEs. The U2000 automatically creates
NEs after finding NEs that meet the search criteria.
l. Click Close. The NE Discovery dialog box is closed.
NOTE
If you still need to create some NEs, repeat the preceding steps.
3. Select an NE layout.
a. Double-click in the Main Topology to access the IP RAN. Right-click and choose
Layout from the shortcut menu.
b. In the Layout dialog box, set the layout type of NEs. Click OK.
4. Create links.
a. Choose File > Discovery > Link from the main menu.
b. Optional: Choose to select Do you want to synchronize LLDP data on the
equipment? above the object list.
c. Select one or more NEs or subnets from the list on the left and click .
d. In the LLDP Status Management dialog box, perform the following operations:
If LLDP has been enabled for NEs, links will be automatically created when NEs are
being searched. LLDP needs to be enabled because it is disabled by default.
b. In the dialog box that is displayed, click Close.
c. The dialog box indicating It takes 30s before the enabled LLDP takes effect.
Are you sure to perform search? is displayed. Click OK. A progress bar is
displayed indicating the search progress.
e. After the search is complete, a dialog box is displayed indicating that the operation is
successful. Click Close. Link search results are displayed.
f. In the Link Search window, select all the links that have been searched out and click
Create. A progress bar is displayed indicating the link creation progress.
g. After creation, a confirmation dialog box is displayed. Click Close.
h. The dialog box indicating Are you sure to import links as fibers/cables is displayed.
Click OK. The Import Link dialog box is displayed.
i. Select links and click to import all the link information to Selected Link. Click
OK. The U2000 then automatically creates fibers.
j. Drag the NE icon to adjust the structure of the network topology.
5. Synchronize NE data.
Select all NEs in the Main Topology, right-click, and choose Synchronize NE Data from
the shortcut menu.In the dialog box that is displayed, NE data is then automatically
synchronized from the NEs to the U2000.
NOTE
After NEs are created on the U2000, the NE data is automatically synchronized to the U2000. If some
configurations are delivered to NEs using commands or other methods, perform the preceding
operations to synchronize NE data to the U2000.
Follow-up Procedure
Configure a xFTP watcher.
1. Choose Administration > Settings > xFtpWatcher from the main menu.
2. In the xFtpWatcher dialog box, click Add.
3. In the dialog box that is displayed, set the parameters.
NOTE
l The default values of Username, Password, and Root path of the U2000 xFTP service are
ftpuser, Changeme_123, d: (Windows-based server. If the server does not have drive D, set the
drive where the U2000 is installed as the root directory.) or /opt/backup/ftpboot (Linux-based
server or Solaris-based server for single-server system) or /opt/sybase/data (Solaris-based server
for backup system) respectively.
l If the user password and path of the xFTP service are changed, make sure that Password and
Root path in the xFtpWatcher dialog box are also changed.
l IP address cannot be set to 127.0.0.1.
l In the case of a single-server system, IP address is the IP address of the xFTP server that can
communicate with NEs, that is, the IP address of the U2000 server. In the case of a distributed
system, IP address is the IP address that is configured by means of the network address
translation (NAT).
l Port: Please use the default port ID, and ensure that the port is not occupied.
l The value of Root path must be correct. In addition, Root path must be an absolute path and
cannot end with / or \ or contain a space. On Windows OS, the default value of Root path is "d:"
disk, if the "d:" disk does not exist, please set the non-system disk as the root path of the FTP
server manually.
4. Optional: In the xFtpWatcher dialog box, click FTP Server Setting to set FTP server
parameters such as the password and root path and start or shut down the FTP server.
NOTE
l Click next to Password and change the password for the FTP server in the dialog box that
is displayed.
l By default, the FTP server of the U2000 is started. If you want to stop it, click Stop.
l By default, the root directory of the FTP server is d: on a PC running Windows. If d: does not
exist, set the root directory of the FTP server in a non-system disk.
System Overview
The IP LCT can be used to complete remote commissioning and basic configuration for a large
number of NEs, freeing software commissioning engineers from going to sites and improving
the deployment efficiency.
l The IP LCT provides system-defined templates and baseline templates. You need to set
only a few parameters for generating basic NE configuration scripts.
l The IP LCT supports remote commissioning using the Dynamic Host Configuration
Protocol (DHCP) or through the data communication network (DCN) to rapidly enable
management channels for new NEs. Software commissioning engineers can remotely add
NEs and assign management IP addresses to the NEs, without going to sites. The
configuration scripts are automatically applied to the NEs for site deployment. Currently,
CX600-X1, CX600-X2, CX600-X8-D0, ATN910, ATN950, ATN950B, ATN980, and
ATN990 support automatic NE configuration.
Install hardware
Customize a template
Network planning
engineer
Plan data
U2000
plug-and-play
management
Perform remote Perform remote
commissioning in commissioning in
DCN mode DHCP mode
During deployment, the IP LCT is mainly used to perform DCN configurations for new NEs so
that the U2000 can manage the NEs. The IP LCT can be used to apply basic configurations to
NEs in different networking scenarios to complete batch NE deployment.
U2000 operators can use the IP LCT or UniSTAR for network planning. The plug-and-play
function can be implemented after a planning list is imported to the IP LCT.
System Functions
This topic describes the functions of the IP LCT.
System-defined Template
Configuration templates are defined in the system for IPRAN scenarios. You can select a desired
template and set a few parameters to generate a script.
Remote Commissioning
The IP LCT supports two remote commissioning methods:
l Remote commissioning using DCN: An NE automatically negotiates a route using a routing
protocol after it is powered on. The U2000 connects to the NE through the gateway NE by
Telnet and applies basic configurations to the NE.
l Remote commissioning using DHCP:
The IP LCT integrates with a DHCP server. After an NE is powered on, it exchanges DHCP
packets with the IP LCT through the upstream NE and obtains an IP address. The IP LCT
applies basic configurations to the NE.
Basic Concepts
This topic describes the basic concepts related to the IP LCT.
DHCP
DHCP is a technology used to dynamically manage and configure users in a centralized manner.
DHCP adopts the C/S communication mode, in which the DHCP client sends the configuration
request (requesting for the IP address, subnet mask, or default gateway) to the DHCP server,
and the DHCP server returns the corresponding configuration according to the predefined policy.
DHCP Server
The DHCP server is responsible for assigning IP addresses to DHCP clients. After a DHCP
client sends a configuration-requesting packet (requesting for the IP address, subnet mask, or
default gateway) to the DHCP server, the DHCP server returns a packet carrying the requested
configuration according to the predefined policy. The request and reply packets are both
encapsulated with UDP.
DHCP Relay
DHCP relay is introduced to transmit packets between the DHCP client and DHCP server that
are on different network segments. The DHCP relay agent can transparently transmit DHCP
broadcast packets between the DHCP client and DHCP server that are on different network
segments.
In the actual network environment, the DHCP relay function is generally implemented on a
specific interface of a router. You need to configure an IP relay address on this interface to
specify the DHCP server.
The IP relay address refers to the IP address of the DHCP server specified on the DHCP relay
agent. After the DHCP relay function is configured on an interface, the DHCP broadcast packets
received on this interface are sent to the specified DHCP server.
Upstream NE
NE role relationships should be described in the IP LCT link planning table according to the
order for making NEs online. If an NE at one end of a link is planned to go online earlier than
the other end, this NE can be regarded as the upstream NE.
The preceding figure shows that ASG3 and ASG4 are the NEs that have been made online on
the network. CSG1 and CSG2 are the plug-and-play NEs to go online. All the NEs are planned
to go online in the following time order: ASG3 -> CSG1 -> CSG2 -> ASG4. Port configuration
is also implemented in the same order. In this case, CSG1 is the upstream NE for CSG2. If the
NEs go online in the order of ASG4 -> CSG2 -> CSG1 -> ASG3, CSG2 is the upstream NE for
CSG1.
Note that specifying ASGs as upstream NEs is recommended in any cases. In the preceding
order examples, ASG4 is the upstream NE for CSG2 and ASG3 is the upstream NE for CSG1.
NEs deployed at both ends of a link between ASGs, ASGs and RSGs, and RSGs can act as
upstream NEs.
The upstream NE concept indicating the relationship between NEs on the same link is used for
filling the planning table and implementing remote commissioning only. It is not an absolute
concept. The relationship between a pair of NEs can be exchanged by changing the upstream
and downstream NEs' functions during remote commissioning. The upstream NE in this scenario
is irrelevant to the upstream NE for services.
Main Window
This topic describes main window components of the IP LCT as well as the functions of each
component.
1. Main menu: The main menu options for the IP LCT are: Deployment Configuration,
Script Management, Template Management, System Management, and Help.
2. Global information: The global information includes the networking scenarios and NE
information for sites.
3. Process: The whole process ranges from network planning to service configuration
deployment.
Shortcut Icons
This topic describes the functions of shortcut icons used for the configuration of scripts or
templates.
Previous Error Locates the previous incorrect command line in the current
script.
Next Error Locates the next incorrect command line in the current script.
Restore Defaults Restores the commands and parameter values in the system-
defined template to their default status.
NOTE
Only the system-defined template can be restored to its default status.
To be online Initial status of the NE. The NE has not been establish
an connection to the IP LCT.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 In the Set a Network Scenario dialog box, select a service scenario.
Step 6 Optional: Choose System Management > Set Global Options from the main menu. In the
dialog box that is displayed, click the Options for Remote Commissioning tab and set remote
commissioning parameters.
Parameter Description
Deploy ASG NE's access ring If the check box is selected, the IP LCT applies basic access-
script automatically when side configurations to aggregation site gateways (ASGs)
CSG NE belongs to it is getting after cell site gateways (CSGs) go online. The check box
online needs to be selected when ASGs do not have basic
configurations.
By default, this check box is selected.
Deploy ASG NE's Peer script If the check box is selected, the IP LCT applies Border
automatically when CSG NE Gateway Protocol (BGP) peer configurations to ASGs after
belongs to it is getting online CSGs go online.
By default, this check box is selected.
DHCP Options
Deploy Script Automatically If this check box is selected, the IP LCT applies a script after
establishing a management channel with an NE by means
of plug-and-play.
If this check box is not selected, you can apply scripts
manually.
By default, this check box is selected.
Parameter Description
Disable Relay Automatically If this check box is selected, DHCP relay is automatically
disabled for the upstream NE after the IP LCT assigns an IP
address to and configures a default route for the new NE.
NOTE
If multiple new NEs are connected to the upstream NE, do not select
this check box. Otherwise, DHCP relay is disabled for the upstream
NE and other NEs cannot communicate with the IP LCT using
DHCP after one of the new NEs is connected to the IP LCT.
By default, this check box is selected.
Remove Default PnP Route During the process of using plug-and-play to create an NE,
Configuration Automatically a default route destined for the IP LCT is configured for the
new NE.
If this check box is selected, the IP LCT deletes this default
route after a script is applied to the new NE.
By default, this check box is not selected.
No check for Interfaces of The IP LCT matches information in a DHCP packet sent by
Uplink NEs (available when a new NE with information in the NE planning table. If the
ESN is configured) information is the same, the IP LCT assigns an IP address
to the new NE.
If this check box is selected and some NE information does
match, the IP LCT continues matching the equipment serial
numbers (ESN) in the DHCP packet and NE planning table.
If the ESNs are the same, the IP LCT ignores the mismatch
information and assigns an IP address to the new NE.
By default, this check box is not selected.
Synchronize Uplink NE If the sysname for the upstream NE is different from that in
sysname Automatically the planning table, the IP LCT changes the sysname in the
planning table to the one for the upstream NE.
By default, this check box is not selected.
Update Relay Interface IP If this check box is selected, the IP LCT updates the IP
Addresses of Uplink NE address of the relay interface on the upstream NE after a
Automatically script is applies to a new NE.
By default, this check box is not selected.
Parameter Description
Route Isolation If the route between the IP LCT and the management IP
address of the DHCP relay agent, not the relay interface, is
reachable, you can select this check box to forward DHCP
packets from the management IP address to the IP address
of the relay interface.
By default, this check box is not selected.
Step 7 Optional: On the Extend Script Settings tab, set related parameters and click OK.
Name Description
Merge Extend Script to If this check box is selected, the extended script generated using
Basic Configuration Script the extended template selected when the planning table is
Automatically exported is automatically integrated into the basic
configuration script.
By default, this check box is selected.
Sort DCN Configuration by If this check box is selected, the query result is sorted by ring
Ring Automatically when you view the data communication network (DCN) link
list.
NOTE
Navigation path for viewing the DCN link list: Choose Data
Planning > DCN Planning from the navigation tree on the Automatic
NE Configuration tab.
By default, this check box is not selected.
----End
Context
A DCN type needs to be set only when NEs get online in DCN mode, but not DHCP mode.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 On the DCN Mode Settings dialog box, select a DCN deployment mode.
l DCN Public Mode: The management packets between the U2000 and NEs are forwarded
using the service route.
l DCN Private Mode: The management packets between the U2000 and NEs are forwarded
using an independent private IGP route. The route is logically isolated from the service route.
– Local VRF: All NEs are bound to the same VRF to establish private management channels
for packet transmission.
– DCN VPN: Private management channels provided at delivery are used to transmit
packets. All NEs must support the DCN management function.
----End
Customizing Templates
This topic describes how to use the IP LCT to customize a basic NE configuration template and
a BGP peer configuration template.
Context
l Available network scenarios are hierarchy virtual private network (HVPN), L2+L3,
Gateway, multiprotocol label switching transport profile (MPLS-TP), and Native IP. One
of the network scenarios is deployed at an IP radio access network (IPRAN) site.
l Available NE roles are aggregation site gateway (ASG), cell site gateway (CSG), radio
service gateway (RSG), ACCESS-P and AGG-P. If multiple NE roles need to be deployed
at a site, create multiple site-specific templates. The procedure for creating a basic
configuration template for ASGs is used as an example.
l The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal
information secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Click Create Basic Configuration Template if it is the first time you use Customize a
Template.
If a site-specific template has been created, click Modify Basic Configuration Template.
A site-specific template can be modified as needed. For example, you can insert commands into
or delete commands from the template, or make extended marks on parameters.
Step 5 In the dialog box that is displayed, select a network scenario and an NE role, set an IP address
for the master server of the U2000, and click Next.
NOTE
You can select multiple NE roles in this step and set template parameters in follow-up steps.
l If multiple NE roles have been selected, click associated NE tabs and set template parameters.
l The basic configuration template includes basic NE configurations, such as basic NE information, and
authentication, authorization and accounting (AAA) user, global MPLS, Interior Gateway Protocol
(IGP), loopback interface, ring interface, and Simple Network Management Protocol (SNMP)
configurations.
You can select an extended parameter predefined in the template or create an extended
parameter as needed.
a. In the Select Parameter dialog box, click Create Parameter.
b. In the dialog box that is displayed, enter the parameter ID, name, type, and description,
and click OK.
----End
Context
l The basic configuration template does not contain BGP peer configuration commands.
Therefore, BGP peer configuration templates must be created to deploy BGP peer
configurations.
l The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal
information secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
If a peer configuration template has been created, click Modify Peer Template.
A peer configuration template can be modified as needed. For example, you can insert commands
into or delete commands from the template, or make extended marks on parameters.
Step 5 In the dialog box that is displayed, select route reflector type and desired peer configuration
template type, enter the local AS number.
NOTE
l The available options of Route Reflector (RR) Type are Independent RR, RSG As RR, and Without
RR.
l If a global AS number is available, enter this AS number. Alternatively, enter AS numbers for each
BGP peer configuration template at the next step.
Step 8 Set Template name, AS Number, and BGP Group Name for each peer configuration template.
Step 9 Optional: Modify the peer configuration templates based on service planning.
1. Click Show Detail.
2. Click to expand the template. Select desired check boxes based on service planning to
choose configurations to be applied to NEs.
----End
Planning Data
Plan link data, data communication network (DCN) data, and Border Gateway Protocol (BGP)
peer relationships.
Prerequisites
A project template has been configured.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
To apply configurations except the basic configuration template, click Choose Extend
Template. To configure a routing policy and a clock priority, select an extended template.
In the dialog box that is displayed, select the extended template to be applied and click
OK.
4. In the dialog box that is displayed, click Save File.
5. Click OK.
6. Select a path for saving the link planning table, enter the planning table name, and click
Save.
7. Open the link planning table and enter link planning information based on Note.
The parameters marked with asterisks (*) on each sheet are mandatory.
Sheet Description
8. Click Save.
4. Click Open.
5. Click Next.
If the selected planning table is not exported from the IP LCT or UniSTAR, specify the
mappings for each field in the planning table.
6. In the Configuration Rules for Link Planning area, select the Automatic
configuration check box and click Configure. In the dialog box that is displayed, set the
label switching router (LSR) ID network segment, IP network segment, and access interface
parameters.
NOTE
If the LSR ID and the IP address of the interconnected interface have been entered in the planning
table, clear the Automatic configuration check box.
7. In the DCN Mode area, set DCN Mode and IGP Type.
8. Optional: In the DCN Address Pool Planning area, select the Automatic
configuration check box and click Advanced. In the dialog box that is displayed, plan the
DCN address pool.
NOTE
l DCN Address Pool Planning needs to be set only when DCN Mode is set to Private (local
VRF in private DCN mode).
l If DCN Mode is set to Local VRF, Management Channel Name must be set.
9. Click OK.
10. Click Next. In the dialog box that is displayed, click OK.
11. In the dialog box that is displayed, select a template for each NE and click Next.
12. On the Select Peer Template tab, modify the peer configuration templates mapping to the
NEs based on site conditions, and click Finish.
The desired NEs are displayed under NE List in the navigation tree, and the scripts to be
applied to these NEs are available under these NEs.
3. Ensure that configurations in each script are the same as those planned.
The scripts are automatically generated based on project templates and planning tables and
cannot be manually modified. To adjust configurations in a script, modify the template or
planning table and re-import the planning table.
----End
Result
1. Click the Automatic NE Configuration tab.
2. After you choose Configuration Data > Link Planning from the navigation tree, you can
find that the information has been imported from the planning table to the IP LCT.
Example
The examples of filling in link planning tables in four typical interface scenarios are as follows:
l Scenario in which interfaces are connected, with the link between CSG1 and CSG2 as an
example
NOTE
NOTE
NOTE
NOTE
Prerequisites
l The U2000 client has been started and is unlocked.
l Gateway NEs have been managed by the U2000.
l The gateway NEs are not third-party NEs.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 In the Deployment Overview area, click DCN Type.
Step 4 Click Monitor NE Online Process.
Step 5 In the dialog box that is displayed, click OK.
The DCN view is displayed on the U2000 client.
Step 6 Click , or right-click the Gateway NE Tree node in the navigation tree, and choose Set Gate
NE from the shortcut menu.
Step 7 In the dialog box that is displayed, click Add Gateway NE to select the desired gateway NEs.
Select an NE IP address pool if the private DCN mode is used.
Step 8 Click Telnet Template to set Telnet or STelnet parameters. Click OK.
NOTE
You are advised to use the more secure STelnet mode if this mode is supported.
After the operation succeeds, the added gateway NEs are displayed under the Gateway NE
Tree node. The non-gateway NEs to go online are displayed in the DCN view in the right pane
of the window. In this case, these NEs are dimmed.
Step 9 Power on the non-gateway NEs to go online.
Step 10 Right-click in a blank area in the DCN view and choose Synchronize from the shortcut menu.
The DCN view can be updated by clicking . The non-gateway NEs have been online after
their colors are changed to blue or Status on the NE tab is displayed as Online.
Step 11 Select the online non-gateway NE, right-click, and choose Apply Basic Configuration from
the shortcut menu.
Step 12 In the dialog box that is displayed, browse the scripts to be applied and click Apply.
View associated logs after the scripts are applied. If some commands are failed to be applied,
use Telnet or STelnet to log in to the NEs and re-apply these commands to the NEs.
NOTE
Views logs, you can search for logs by search forward, circle search, or case matching.
The colors of the non-gateway NEs in the DCN view are changed from blue to green after scripts
are successfully applied to them.
----End
Prerequisites
The upstream NEs have been managed by the U2000.
Context
Configurations must be applied to the upstream NEs during remote commissioning. Therefore,
the Telnet or STelnet parameters must be configured for these NEs in advance.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 5 In the dialog box that is displayed, set Telnet parameters for every uplink NE, and click Test
Connectivity.
NOTE
STelnet is more secure than Telnet. Using STelnet is recommended.
If the test succeeds, the routes between the IP LCT and uplink NEs are reachable.
----End
Remote Commissioning
After the DHCP service is enabled, the IP LCT automatically sets up a management channel for
newly added NEs and deploys configurations planned in the template to the associated NEs.
Context
After the DHCP service is enabled, the IP LCT starts exchanging DHCP messages with NEs.
After receiving DHCP request messages from the newly added NEs, the IP LCT assigns IP
addresses for the newly added NEs based on the planning information. A management channel
is then set up for the newly added NEs. The IP LCT automatically generates configuration scripts
based on the configured template and planned data and deploys the configuration scripts to the
newly added NEs.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
NOTE
Select each NE and view logs and scripts on the Running Log and Configuration Script tab pages. For
NEs with Eth-Trunk interfaces, the Trunk Interface Message Log tab page is also displayed, on which
you can view Trunk interface packet logs.
1 Check uplink NEs. The IP LCT checks uplink NE information for each newly
added NE, including the uplink NE name and IP address.
2 Check and The IP LCT checks interface information for newly added
commission newly NEs and deploys scripts.
added NEs
3 Disable relay for The IP LCT automatically disables relay for interfaces on
uplink NEs. uplink NEs.
----End
Troubleshooting Procedure
Abnormality case 1: The newly created NE is online, but some planning information needs to
be modified.
Abnormality case 2: After relay has been enabled for an uplink NE during remote
commissioning, the newly added NE is in the To be online state.
NOTE
Relay has been enabled for an uplink NE but scripts fail to be deployed, which indicates that the
configurations of the newly added NE are not empty. Clear up the empty configurations.
1. Select the problem NE, right-click, and choose Send DHCP Packets from the shortcut
menu.
2. In the dialog box that is displayed, click OK.
Follow-up Procedure
After remote commissioning is complete, you are recommended to delete confidential password
information such as the user password from the project template.
Maintaining NEs
This topic describes how to maintain NEs.
Context
You are advised to plan the address pools if a great number of NEs need to be deployed. If you
do not plan the address pools, you can fill out the planning table with the IP address pool
information.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 6 In the dialog box that is displayed, set parameters for the IP address pools. Click OK.
Three types of IP address pools can be created, including the LSR ID address pool, management
IP address pool, and link IP address pool.
----End
Context
The BGP peer relationships between NEs can be created independently or in batches. You can
select Full MESH or HUB/SPOKE for creating the BGP peer relationships in batches.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
----End
Procedure
Step 1 Log in to the U2000 client.
Step 2 Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
The U2000 IP Plug-and-Play Management window is displayed.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Click the Script tab.
Step 4 In the NE List navigation tree or folder, right-click NE List and choose Synchronize NMS and
NESync NE From VSM from the shortcut menu.
Step 5 In the Synchronize NMS and NESync NE From VSM dialog box, set query conditions and
click Query.
Step 6 Select the NE to be imported and click OK.
The imported NE is displayed in the NE List navigation tree and NE List.
----End
Follow-up Procedure
To check whether the NE communicates with the IP LCT properly, perform the following
operations:
Prerequisites
Routers or switches are available in the U2000 Main Topology.
Context
An .xlsx file exported by the IP LCT contains the interface, IGP route, and board information
about NEs.
The file can be used as input for network expansion planning and be directly imported to the
Unistar.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Choose Deployment Configuration > Export NMS Data from the main menu.
Step 4 In the dialog box that is displayed, click Save File and OK.
----End
Prerequisites
The IP LCT and new NEs are directly connected through network cables.
Context
After the DHCP service is enabled, DHCP packets are exchanged between the IP LCT and NEs.
After receiving a DHCP request packet from a new NE, the IP LCT assigns an IP address to the
NE's interface directly connected to the IP LCT to enable the device management channel.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Choose Deployment Configuration > Direct Mode Remote Commissioning from the main
menu.
Step 4 In the dialog box that is displayed, set the IP address to be assigned, mask to be assigned, and
IP address of the DHCP server, and click Start.
----End
Prerequisites
NEs must be added to the IP LCT and the connectivity check must be performed successfully.
For details about how to add NEs, see Synchronizing NE Configurations to the U2000.
Context
l Check whether the NE type and version are empty in the NE list. If the NE type and version
are not empty, the command sets of the NE have been obtained by the IP LCT and you do
not need to click Obtain Command Set.
l If no command set is obtained, check whether the Telnet/STelnet parameters of the NE are
correct by clicking Test in the General area in the NE list. If the test failed, reset the Telnet/
STelnet parameters for the NE. Command sets can be obtained only after the test succeeds.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 In the NE List navigation tree, select the NE whose command set needs to be obtained, right-
click, and then choose Obtain Command Set from the shortcut menu.
Alternatively, choose Script Management > NE > Obtain Command Set from the main
menu.
A progress bar is displayed indicating the progress of obtaining the command set.
----End
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 5 In the NE List navigation tree, right-click NE List and choose Create NE from the shortcut
menu.
You can also right-click in the NE List area and choose Create NE from the shortcut menu.
Alternatively, choose Script Management > Folder > Create NE from the main menu.
Step 6 In the Create NE dialog box, set NE parameters, and then click OK.
NOTE
l If the NE script needs to be exported or merged in the future, the NE name cannot contain special
characters \ / : * ? < > |.
l If the NE type and NE version currently in use are not available for the NE type and NE version
parameters, obtain the required command set. After the command set is obtained, the NE type and NE
version are automatically added to NE information. For details, see Obtaining Command Sets.
l To create multiple NEs in batches, click Create in the Create NE dialog box. Then, set the NE
parameters.
The created NE is displayed in the NE List navigation tree and on the NE List tab page.
----End
Follow-up Procedure
Check whether the NE and IP LCT are connected properly.
1. Choose NE List from the navigation tree, and select a new NE in the NE List area on the
right.
2. Optional: In the General area, you can modify the NE parameters and then click Apply
to complete the modification.
3. In the General area, click Test Connectivity.
4. In the Confirm dialog box, click OK.
l If the message Test succeeded. is displayed, the IP LCT communicates properly with
the new NE.
l If the message Test failed. The target NE cannot be reached. is displayed, the NE IP
address is incorrect.
l If the message Test failed. Check the user name and password. is displayed, the user
name and password for authentication are incorrect.
Prerequisites
Global plug-and-play parameters must have been set. For details, see Setting a Network
Scenario.
DHCP replay must have been enabled for the uplink NE.
The uplink NE for the NE to be created must have been added to the IP Local Craft Terminal
(LCT).
Context
l Create planning information about the NE to be created, and then start the Dynamic Host
Configuration Protocol (DHCP) service. The NE will be automatically assigned an IP
address and added to the IP LCT.
l The DHCP service is stopped on the IP LCT by default.
l If you have completed deployment by using automatic NE configuration or will not use
automatic NE configuration, it is recommended that the DHCP server be stopped to save
server resources.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Choose Data Planning > NE Information from the navigation tree.
Step 7 Click OK. The new planning record is displayed in the NE list.
----End
Context
The information about some NEs or all NEs can be exported as needed.
Procedure
l To export information about some NEs into a file, perform the following operations:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree.
5. Hold down Ctrl and select the desired NEs in the right-hand NE List area.
6. Right-click the selected NEs and choose Export NE from the shortcut menu.
7. In the dialog box that is displayed, click the Save File option button and click OK.
NOTE
If the Internet Explorer is used, the Save As dialog box is displayed. Select the path for saving the
exported file.
l To export information about all NEs into a file, perform the following operations:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree.
5. Click Export All NEs in the right-hand NE List area.
6. In the dialog box that is displayed, click the Save File option button and click OK.
NOTE
If the Internet Explorer is used, the Save As dialog box is displayed. Select the path for saving the
exported file.
----End
Prerequisites
NEs must exist in the NE list.
Procedure
Step 1 Click the Automatic NE Configuration tab.
Step 2 Choose Automatic NE Configuration > Remote Commissioning from the navigation tree.
----End
Result
l If the operation is successful, it indicates that the destination host is reachable. In the Result
area, the information indicating the normal connection is displayed. The information
includes the number of sent packets, number of received response packets, percentage of
no-response packets, and minimum, maximum, and average response time.
l If the operation fails, it indicates that the destination host is unreachable and the network
connectivity or line failure cannot be detected. The Request timed out message is
displayed.
Maintaining Templates
This topic describes how to maintain templates.
Creating a Template
This topic describes how to create a template. A lot of NEs need to be configured during network
configuration. You can create a template for NEs of the same type and apply the template to
these NEs. This improves script generation efficiency.
Prerequisites
A template is a predefined and exported .zip file. The template to be imported must exist.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Select the Template List node, right-click, and then choose Import Template from the shortcut
menu.
Alternatively, choose Template Management > Folder > Import Template from the main
menu.
Step 5 In the dialog box that is displayed, click Browse, and then select the template to be imported.
Step 6 Click Import. The imported template is displayed in the navigation tree.
----End
Prerequisites
Inheritable scripts must be obtained.
Context
Existing scripts can be classified into the following types:
l Sample scripts in the LLD document
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Choose NE List from the navigation tree. Select the NE to be configured, right-click, and then
choose Create Script from the shortcut menu.
Alternatively, choose Script Management > NE > Create Script from the main menu.
Step 5 In the Create Script dialog box, set Script Name and Description, and then click OK. The
created script is automatically generated under the associated NE node.
Step 6 Click Modify to copy sample scripts in the LLD document or saved scripts to the blank area in
the right pane and modify them as required.
NOTE
If there are a large quantity of commands in scripts, click Find/Replace to modify scripts.
Step 9 In the Verification Result dialog box, view the verification result for each command.
l If the verification result of a command is Error, take the following operations:
Click Close. In the text box for command query, enter the command and press Enter to check
whether the NE supports the command. Then, modify the command in the Script
Configuration area.
NOTE
Enter only the keyword of the command to be queried. Do not enter any command parameter.
l If the verification result of a command is Ambiguous Match, take the following operations:
Click Close. In the text box for command query, enter the command and press Enter. The
value range for the parameter in the command is displayed. Based on this range, modify the
command in the Script Configuration area.
Step 11 In the Generate Template dialog box, modify the parameters in commands as required.
Step 13 In the dialog box that is displayed, set Template Name, Template description, and Application
scenario.
Step 14 Click OK. A message is displayed indicating that the operation is successful.
----End
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 In the Template List navigation tree, right-click the Template List node and choose Create
Folder from the shortcut menu.
Alternatively, choose Template Management > Folder > Create Folder.
Step 5 In the Create folder dialog box, enter a folder name, and click OK.
Step 6 In the Template List navigation tree, right-click the Template List node and choose Create
Template from the shortcut menu.
Alternatively, choose Template Management > Folder > Create Template from the main
menu.
Step 8 Select a path for saving the template, set NE type and NE version related to the template, and
enter basic template information. Then, click OK.
Step 9 In the Insert dialog box, select a value from the Select View drop-down list.
Step 10 In the Query Command field, enter the keyword of the command to be queried.
All commands containing this keyword are displayed in the query result area.
Step 11 Click to add the required commands to the list of selected commands. Then, click
OK.
You can also copy a command script to the blank area directly.
Click OK.
If command verification succeeds, the command is inserted into the template. If command
verification fails, the message Failed to verify the script is displayed. Modify the command
and insert it into the template again.
The created template is displayed in the navigation tree, and details about the template are
displayed in the Template Configuration area.
----End
Modifying a Template
This topic describes how to modify commands and parameters in a template.
Context
Custom project templates can be modified, and predefined templates cannot be modified.
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
For details about how to modify a VTL template, refer to the procedure for creating a VTL template.
Step 4 Choose the template to be modified under Project Template from the navigation tree. All
commands and parameters of the template are displayed in the right pane. You can modify the
template using the following methods:
l Double-click a command or view to modify the related description.
NOTE
l Lines started with asterisks (*) indicate mandatory parameters in the command. If these
parameters are not set, the command does not take effect.
l If the descriptions of two parameters in a template are the same, the parameters are combined
into one in the exported template.
l If a command contains parameters of the enumerated type and the enumerated parameter values
are incomplete, modify the command to add values. For example, in the authentication-mode
aaa command, aaa indicates that the authentication mode is AAA. The other two authentication
modes are password and none. If you change aaa into ENUM{aaa,none,password} in the
command, any authentication mode can be selected as needed when you set parameters.
l Insert a command into the template.
1. Click . In the dialog box that is displayed, select the desired view and command.
3. You can also copy a command script to the blank area directly.
4. Click OK.
If command verification succeeds, the command is inserted into the template. If
command verification fails, the message Failed to verify the script is displayed.
Modify the command and insert it into the template again.
l Enter default parameter values. Double-click the parameter value column to enter or change
parameter values.
The parameters marked yellow in the Default Value column are mandatory.
The rules of assigning values to some parameters in the Default Value column can be
modified.
For example, the default value assignment rule for ISIS Name under ISIS
Configuration is =add(sysname,igpid). That is, the value of ISIS Name is sysname
+igpid. To meet site requirements, the rule can be changed to =sysname, and the value of
ISIS Name is sysname.
NOTE
Leave a space between the command and each square bracket.
2. Click OK. A check box is displayed to the right of the command. If the check box is
selected, it indicates that the command needs to be executed. If the check box is not
selected, it indicates that the command will not be executed.
l Copy and paste commands.
1. Select the commands to be copied or the view in which commands need to be copied,
and then click to copy the commands.
NOTE
Items in either the current template or another template can be copied.
----End
Applying a Template
This topic describes how to quickly generate a script by using a template.
Context
Both customized templates and universal templates can be used to generate scripts.
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 In the Template List navigation tree, right-click the template to be used and choose Apply
Template from the shortcut menu.
Alternatively, choose Template Management > Template|Systemplate > Apply Template
from the main menu.
Step 5 In the Apply Template dialog box, select the template to be used in the Select NE area. Then,
click Next.
You can also select multiple templates and then apply them to an NE or select a template and
then apply it to multiple NEs.
Step 6 On the Set Parameter tab page, set the command parameters, and then click Finish.
NOTE
l In a command, the parameters marked with an asterisk (*) or the value of Necessary is Yes must be
set. If such a parameter is not set, the generated scripts do not contain the command.
l If multiple templates are selected, set the parameters of each template respectively.
Step 7 In the confirmation dialog box, click Yes or No to determine whether to deploy the script
immediately.
----End
Follow-up Procedure
1. Click the Script tab.
2. Choose the equipment where the template is applied from the NE List navigation tree. You
can find that the created script is displayed under the equipment. The name of the script is
the same as the name of the applied template.
Prerequisites
l NEs must be created or imported.
l A template must be created or imported.
l All the required information must be entered for the exported planning table.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Choose NE List from the navigation tree. Right-click NE List and choose Import Planning
Table from the shortcut menu.
Alternatively, choose NE Plan Table > Import from the main menu.
Step 5 In the dialog box that is displayed, click Browse to select the network data planning table.
If the Replace same-name script check box is selected, scripts with the same name are replaced.
If the Replace same-name script check box is not selected, scripts generated subsequently will
be named based on the previous script name. For example, if a script named Interface
Configuration(1) already exists, after a planning table is imported, the script name is Interface
Configuration(2).
----End
Exporting Templates
This topic describes how to export templates. The tool supports the exporting and backup of all
templates for follow-up template modification or for reference.
Context
You can choose to export some templates or all templates as required.
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
l To export some templates, do as follows:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
Enter a user name and a password for logging in to the U2000 and click Login.
If the Internet Explorer is used, the Save As dialog box is displayed. Select the path for saving the
exported file.
l To export all templates, do as follows:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Template tab.
4. Choose Template List from the navigation tree. All templates are displayed in the
right pane.
5. Click Export All Templates.
6. In the dialog box that is displayed, click the Save File option button, and then click
OK.
----End
Maintaining Scripts
This topic describes how to maintain scripts.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
You can create a script in any of the following methods. This topic focuses on the method of
creating a script manually.
l Create a script manually.
Procedure
Step 1 Log in to the U2000 client.
Step 2 Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
The U2000 IP Plug-and-Play Management window is displayed.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Click the Script tab.
Step 4 In the NE List navigation tree, select the NE for which the script needs to be created, right-click,
and then choose Create Script from the shortcut menu.
Alternatively, choose Script Management NE > Create Script from the main menu.
Step 5 In the Create Script dialog box, set Script Name and Description, and then click OK.
If the NE script needs to be exported or merged in the future, the script name cannot contain
special characters \ / : * ? < > |.
The created script is displayed under the NE node.
Step 6 In the Script Configuration area, click to modify the script.
Step 7 Enter commands in the blank area.
After entering a command keyword in the query box, click or press Enter to query
commands related to the command keyword.
NOTE
If characters in the script are displayed in black after you click to save the commands, it indicates that
the type and version of the NE have not been set. In this case, you must obtain the command set.
Step 9 Optional: Incorrect commands are displayed in red. Modify the incorrect commands, and then
click to save the new configurations.
----End
Modifying a Script
This topic describes how to modify a script of an NE.
Prerequisites
The script must exist on the NE.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Choose NE List from the navigation tree. Then, select the script to be modified under an NE
node.
----End
Exporting Scripts
This topic describes how to export scripts. You can use the tool to export NE scripts. The exported
scripts can be used for follow-up script verification or fault location, and provide reference for
the configuration of other NEs.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
l To export some scripts, do as follows:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
The U2000 IP Plug-and-Play Management window is displayed.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree. Then, click the NE whose scripts need to
be exported. All scripts of the NE are displayed in the right pane.
5. Hold down Ctrl while selecting the scripts to be exported. Right-click these scripts
and choose Export Script from the shortcut menu.
Alternatively, choose Script Management > Script > Export Script from the main
menu.
6. In the dialog box that is displayed, click the Save File option button, and then click
OK. Select the required path and click Save.
NOTE
If the Internet Explorer is used, the Save As dialog box is displayed. Select the path for saving the
exported file.
l To export scripts of all NEs, do as follows:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
The U2000 IP Plug-and-Play Management window is displayed.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree. Then, select any of the NEs whose scripts
need to be exported. All scripts of the NE are displayed in the right pane.
5. Optional: Select All from the Attribute drop-down list. Then, click Query.
6. Click Export All Scripts.
7. In the dialog box that is displayed, click the Save File option button, and then click
OK. Select the required path and click Save.
----End
Importing Scripts
This topic describes how to import scripts. You can use the tool to import the scripts of other
NEs to the target NE. If the methods of configuring different NEs are similar, this function
greatly improves the efficiency of making scripts.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Choose NE List from the navigation tree. All NEs are displayed in the right pane.
Step 5 Select one or more NEs for which scripts need to be imported, right-click, and then choose
Import Script from the shortcut menu.
Alternatively, choose Script Management > NE > Import Script from the main menu.
Step 6 In the dialog box that is displayed, click Browse to choose the scripts to be imported.
----End
Verifying a Script
This topic describes how to verify the script for an NE in offline mode to check the script syntax
according to the related command set.
Prerequisites
l Created scripts must exist. For details about how to create a script, see Creating a Script
Manually.
l NE version and NE type must be set correctly for the specified NE.
l The command set for the NE whose script needs to be verified must exist on the IP LCT
or have been imported into the IP LCT.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Click the Script tab and select a script under the NE. The number of errors in the script is
automatically displayed above the Script Configuration area.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Click the Script tab. In the NE List navigation tree, select the script to be verified, right-click,
and then choose Verify Script from the shortcut menu.
Alternatively, choose Script Management > Script > Verify Script from the main menu.
Step 4 In the Verification Result dialog box, view the verification result for each command.
l If the verification result of a command is Error, take the following operations:
Click Close. In the text box for command query, enter the command and press Enter to check
whether the NE supports the command. Then, modify the command in the Script
Configuration area.
NOTE
Enter only the keyword of the command to be queried. Do not enter any command parameter.
l If the verification result of a command is Ambiguous Match, take the following operations:
Click Close. In the text box for command query, enter the command and press Enter. The
value range for the parameter in the command is displayed. Based on this range, modify the
command in the Script Configuration area.
----End
Combining Scripts
This topic describes how to combine multiple NE scripts into one script.
Prerequisites
l All NE scripts must be generated .
l The NE scripts must be correct.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
This function supports the combining of multiple scripts of a single NE or all NEs.
Procedure
l Scenario 1: To combine multiple scripts of a single NE, do as follows:
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree. Then, select the NE whose scripts need to
be combined. All scripts of the NE are displayed in the Script List area in the right
pane.
5. Select a script, right-click, and then choose Select All from the shortcut menu. All
scripts are selected.
6. Right-click these scripts and choose Combine Script from the shortcut menu.
Alternatively, choose Script Management > NE > Combine Script from the main
menu.
7. In the dialog box that is displayed, view the progress of combining scripts. When the
progress bar reaches 100%, click Close.
l Scenario 2: To combine multiple scripts of all NEs, do as follows:
1. Log in to the U2000 client.
2. Choose Configuration > Router/Switch/Security Configuration > Plug-and-Play
Management from the main menu.
Enter a user name and a password for logging in to the U2000 and click Login.
3. Click the Script tab.
4. Choose NE List from the navigation tree. Select an NE under the NE List node. Then,
select All from the Attribute drop-down list.
5. Click Query. The scripts of all NEs are displayed.
6. Select a script, right-click, and then choose Select All from the shortcut menu. All
scripts are selected.
7. Right-click these scripts and choose Combine Script from the shortcut menu.
Alternatively, choose Script Management > NE > Combine Script from the main
menu.
8. In the dialog box that is displayed, view the progress of combining scripts. When the
progress bar reaches 100%, click Close.
----End
Deploying Scripts
This topic describes how to deploy scripts to configure NEs in batches.
Prerequisites
The scripts that have been successfully verified must exist. For details about how to verify a
script, see Verifying a Script.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 In the NE List navigation tree, right-click the script to be deployed or the NE where the script
is to be deployed and choose Deploy Script from the shortcut menu.
Step 5 In the Deploy Script dialog box, select a script in the Select Script area. The details about the
script are displayed in the Preview area.
If some command lines or parameters need to be modified, modify them and click Save before
deploying the script.
Step 8 The progress of deploying the scripts is displayed on the Deployment tab page.
If a script fails to be deployed, perform any of the following operations as needed:
l Retry: The system re-executes the abnormal command.
l Ignore: The system ignores the abnormal command and continues to execute the next
command.
l Stop: The system stops deploying scripts.
----End
Prerequisites
An NE must be created or imported.
Context
The feature you have purchased may obtain or use some personal information of users when
providing services or maintenance. Therefore, you are obliged to formulate a privacy policy
according to the applicable law and take sufficient measures to keep the personal information
secure.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 4 Select the NE List node, right-click, and then choose Scheduled Deployment from the shortcut
menu.
Alternatively, choose Script Management > Scheduled Deployment from the main menu.
Step 6 In the Create Deployment Task dialog box, click or to add the
required NE to the list of selected NEs.
Step 8 Specify the script to be deployed in a scheduled manner. Then, click Next.
NOTE
The script will be automatically deployed in a scheduled manner. Do not enter any MML command.
Step 11 A record about the scheduled task is displayed in the Manage Scheduled Deployment Task
dialog box.
----End
Follow-up Procedure
After creating scheduled tasks, perform the following operations as required:
Context
Changing the HSQLDB password during remote NE commissioning or script deployment is not
recommended. It is recommended that you restart the IP LCT process after changing the
HSQLDB password.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Choose System Management > Change the HSQLDB password from the main menu.
Step 4 In the dialog box that is displayed, enter the initial HSQLDB password, enter a new password
twice, and click OK.
----End
Follow-up Procedure
Restarting the IP LCT process after changing the HSQLDB password is recommended.
Context
You must enter the password twice when you log in to the online plug-and-play NE through
Telnet or STelnet.
Procedure
Step 1 Log in to the U2000 client.
Enter a user name and a password for logging in to the U2000 and click Login.
Step 3 Choose System Management > Change Initial NE Login Password from the main menu.
Step 4 In the dialog box that is displayed, enter the initial NE login password, enter a new password
twice, and click OK.
The initial NE login password is Changeme_123.
NOTE
The password must meet the following requirements to safeguard your user account.
1. Consists of 8 to 32 characters.
2. The password must be a combination of letters, digits, and special characters.
l Lower-case letters
l Upper-case letters
l Digits
l Special characters including ~ ! @ # $ % ^ & * ( ) - _ = + \ |[ { } ] ; : ' " , < . > and /
----End
Fault IP/MPLS Router Choose Fault > IP/MPLS Fault Location from
diagnosis fault the main menu.
location
IP NE test Router Choose Fault > Test Suite from the main menu.
Service
gateway
Frame-shaped
switch
Box-type
switch
Box-type
switch
to NEs. Before you click Apply, all configurations are stored only on the U2000, and the
network and NEs are not affected.
l Typical GUI 2: a list that does not support the creation operation
Configurations on such a GUI are usually implemented using shortcut menu options or
buttons.
– If a shortcut menu option is used, configurations are deployed NEs after the operation
is confirmed.
– If a button is used, a configuration window is usually displayed. The configuration mode
is similar to that on typical GUI 1.
l Typical GUI 3: a list that supports the creation operation and provides tab pages for further
configuration
A logical resource, not a physical resource, is usually created on such a GUI. If the created
logical resource is associated with some features, it can be further configured using tab
pages.
NOTE
If you are not clear about the meaning, system impact, relationship with other parameters, or value setting
rule of a parameter when using the NE Explorer to configure an NE, press F1 to display the associated
help.
Prerequisites
1. The NE has been added to the U2000.
2. The basic configurations related to services on the live network have been deployed to the
NEs.
Application Scenario
On the live network, the DCN Management for Routers function or the CLI mode (applicable
to an earlier U2000 version) is usually used to deploy a universal script to routers in batches in
order to deploy basic configurations. As a great number of NEs exist on the live network and
NE configurations often changes, the parameter settings in the universal script sometimes do
not match the live network. In this case, verifying the basic configuration is required. This
function helps to implement visual and batch basic configuration verification.
Procedure
Step 1 Choose Administration > IP Device Health Check from the main menu.
Step 2 Click Select NE. In the dialog box that is displayed, select the desired NEs and click OK.
NOTE
You can enter IP Device Health Check dialog box using these methods:
l Select the desired NEs in the Main Topology, right-click, and choose IP Device Health Check from
the shortcut menu.
l Choose Administration > DCN Management for Routers from the main menu. In DCN
Management for Routers dialog box, choose the NE on the NE trees, right-click, and choose IP
Device Health Check from the shortcut menu.
The selected check items are displayed. If you move the cursor to a check item. details about the check
item are displayed.
The following figure indicates that the detection has finished and detection results are displayed.
----End
Follow-up Procedure
Based on the detection results, check the causes to items that report faults, locate and rectify the
faults, and perform the detection until all the items are passed.
Prerequisites
The service information does not exist on the U2000 service management module but exists on
NEs.
The desired NE has been added and the relevant NE configurations have been synchronized to
the U2000.
Context
Note that automatically searching for IP services updates IP service data on the U2000. This
operation does not affect NE configurations or services running on NEs.
Procedure
Step 1 Choose Service > Search for IP Service from the main menu.
Major Settings
Parameter
All Service discovery is performed on all the NEs managed by the U2000.
Customer If this parameter is not set, the automatically discovered services are not
Policy associated with any customer. If this parameter is set, all the discovered
services are associated with this customer.
NOTE
During customer creation, some personal data about users may be used. Therefore,
you are obligated to take considerable measures, in compliance with the laws of the
countries concerned and the user privacy policies of your company, to ensure that the
personal data about users is fully protected.
Naming Policy Naming policy for discovered services. This parameter is available only to
L3VPN, VPLS and PWE3 services.
l Automatic: The U2000 automatically generates service names based on
certain rules.
l Obtain from NE: Some NE information is used as the specific service
name.
The following table describes the sub-tab pages on the Discovery Result tab page.
Add Service A service that is added to the NMS using automatic discovery.
----End
Follow-up Procedure
Select one or more records from the list of discovered services and click Jump Service to access
the service management window. In this window, you can perform operations such as viewing
or modifying the service data.
Prerequisites
l Service data has been synchronized to the U2000 and service data on the U2000 is consistent
with that on NEs.
l IP services to be automatically discovered exist on the U2000.
NOTE
If service data on NEs has not been added to the U2000, perform the operations described in 2.2.1
Automatically Discovering Single IP Services. Otherwise, qualified composite services on the NE
side cannot be identified and added to the U2000.
Context
Automatic service discovery updates composite service data on the U2000, without affecting IP
service data on the U2000 and NEs or the running of IP services on the network.
The U2000 supports automatic discovery of the following composite services: H-VPLS, PWE3
+L3VPN, VPLS+L3VPN, inter-AS Option A (PWE3, VPLS, and L3VPN), PWE3+EPL, PWE3
+E-Line, SDH+PWE3, and Terminated EPL+L3VPN.
NOTE
Composite services can also be manually created. For details, see 2.7.2 Creating a Composite Service.
Procedure
Step 1 Choose Service > Composite Service > Search for Composite Service from the main menu.
Major Settings
Parameter
All Service discovery is performed on all the NEs managed by the U2000.
Customer Specify the customer to which the services to be discovered belong. Only the
Name services belonging to this customer can be discovered.
VSI is Source Discover an H-VPLS composite service that uses Only H-VPLS
VSI as the source and consists of one or more PWE3 services support this
services. function.
This method is applicable to the H-VPLS service that
consists of one VPLS node and multiple PWE3
nodes.
Major Settings
Parameter
L3VPN is Use an L3VPN service as the source, and combine Only PWE3+L3VPN
Source it and one or more PWE3 services that meet PWE3 composite services
+L3VPN composite service conditions into a support this function.
composite service.
----End
Follow-up Procedure
Select one or more records from the list of discovered services and click Jump Service to access
the service management window. In this window, you can perform operations such as viewing
or modifying the service data.
Router √ √ √ – –
ATN √ – √ √ √
NOTE
"√" indicates that the device supports the task. "-" indicates that the device does not support the task.
Quick Navigation
The following table lists three tunnel creation methods.
Creating This method is recommended if you need to create dynamic tunnels for
tunnels in multiple NEs and the network type for the new tunnels is Hub-Spoke,
batches Full-Mesh, or Ring.
l Full-mesh: All equipment is fully connected.
l Hub-spoke: The spoke sites are fully connected to hub sites.
l Ring: The equipment is bidirectionally connected in a ring.
Prerequisites
l Data synchronization must be performed for the related NE.
l Layer 2 links or IP links must be configured between routers. For details, see the topology
management section.
Procedure
Step 1 Choose Service > Tunnel > Create Tunnel from the main menu.
Step 2 Configure basic tunnel information such as the protocol type, signaling type, and protection type.
Protocol Type Signaling Type is available only when Protocol Type is set to
MPLS.
l MPLS: If all NEs that a tunnel passes through support MPLS, set
Protocol Type to MPLS.
l IP: To implement a cross-IP ATM or CES service, set Protocol
Type to IP.
Signaling Type l RSVP TE tunnel: You need to specify only the ingress and egress
nodes for an RSVP TE tunnel. The MPLS protocol automatically
calculates a route for the tunnel. In addition, you can specify
constraint nodes to plan a specific route for the tunnel. You can
configure FRR protection and the QoS function for an RSVP TE
tunnel. Therefore, an RSVP tunnel is more flexible and safer than
an LDP tunnel.
l Static CR tunnel: A static CR tunnel is created with certain
constraints. The mechanism for creating and managing those
constraints is CR. Every site that a static CR tunnel passes through
must be manually specified too. Different from a static tunnel that
requires only routing information, creating a CR tunnel has other
configurations, such as the bandwidth, route, and QoS parameters.
l Static tunnel: Every site that a static tunnel passes through must be
manually specified.
NOTE
l Routers do not support LDP tunnels.
Service Direction A bidirectional tunnel has one path in either direction, and the paths use
the same port and route. A unidirectional tunnel has only one path in a
single direction.
NOTE
l To create bidirectional tunnels, you need to create a single tunnel and select
Create Reverse Tunnel. In this way, two tunnels in opposite directions are
created.
l This parameter is available only when Signaling Type is set to Static CR.
Protection Type When Signaling Type is set to Static CR and Protection Type is set
to 1+1 or 1:1, tunnel protection groups are created along with tunnels.
NOTE
l For protection groups of the 1+1 protection type, the source end sends and
receives services, and the sink end selectively receives services. If the
working tunnel fails, the protection tunnel is used to receive services to
implement service switchover. A protection group of the 1+1 protection type
occupies more bandwidth but takes shorter switching time.
l For protection groups of the 1:1 protection type, services are transmitted on
the working tunnel. If the working tunnel fails, the protection tunnel is used
to transmit services. The source end sends services and the sink end receives
services. A protection group of the 1:1 protection type occupies less
bandwidth but takes longer switching time.
l During creation of a tunnel enabled with APS, ensure that the values of
Outbound Interface/Ring and Inbound Interface/Ring for the working
and protection tunnels cannot be the same. If they are the same, APS does
not take effect.
Backup Type Key tunnels on the network require that backup CR-LSPs be configured
for primary CR-LSPs.
l Hot standby: A backup CR-LSP is created immediately after a
primary CR-LSP is set up. If the primary CR-LSP fails, services will
be switched to the backup CR-LSP. If the primary CR-LSP restores,
services will be switched back to the primary CR-LSP.
l Cold standby: A backup CR-LSP is created after a primary CR-LSP
fails. If the primary CR-LSP fails, services will be switched to the
backup CR-LSP. If the primary CR-LSP restores, services will be
switched back to the primary CR-LSP.
l Disabled: A backup CR-LSP is not configured.
NOTE
The U2000 performs route pre-calculation on RSVP TE tunnels only when
Backup Type is set to Hot standby or Cold standby.
Configure BFD Configure BFD when creating a tunnel. Static BFD can be configured
only when Create Reverse Tunnel is selected and Deploy in the lower
left corner is selected.
When Protection Type is set to Hot standby, this parameter is
automatically set to Tunnel BFD Type STATIC. To configure static
BFD, set also BFD for TE and BFD for LSP. To configure dynamic
BFD, set only BFD for LSP.
l BFD for TE: Millisecond-level fault detection and service protection
are available when the primary tunnel does not function properly.
l BFD for LSP: Millisecond-level fault detection and service
protection are available when the primary CR-LSP does not function
properly.
NOTE
l The BFD for TE detection period must be three times longer than the BFD
for LSP detection period. Therefore, the value of MinRescSendInt for BFD
for LSP must be less than that for BFD for TE.
l This parameter is available only when Signaling Type is set to RSVP TE.
Configure As When Signaling Type is set to RSVP TE and FRR protection needs to
Bypass Tunnel be configured to set up a protection tunnel, Configure As Bypass
Tunnel must be set.
Step 3 Double-click NEs in the physical topology to select the desired source and sink NEs and set the
roles of the NEs in the NE Role column.
You can also use the following methods to select source and sink NEs:
l Method 1: Select the desired NE in the physical topology, right-click, and choose Add from
the shortcut menu.
l Method 2:
1. Click Add and choose NE. In the Select NE dialog box, select the desired NEs.
2. Click OK.
To specify the explicit or excluded NEs or interfaces for the tunnel to be created base on planned data,
configure route constraints for the tunnel. Otherwise. select only the source and sink NEs for the tunnel.
l For static CR or static tunnels, right-click the NE in the Main Topology and choose Set
Working Explicit Route > NE/Interface from the shortcut menu. This method is
recommended because route constraints can be configured for both forward and reverse
tunnels. Configured route constraints are displayed on the Route Constraint tab page.
NOTE
Route constraints for static CR or static tunnels are configured for route calculation.
l For RSVP TE tunnels, select the Synchronize Reverse route constraints check box in
Route Constraint. Then right-click the NE in the Main Topology and choose Set Forward
Primary Path Explicit Route > NE/Interface from the shortcut menu. Configured route
constraints are displayed on the Route Constraint tab page.
l For RSVP TE tunnels, click Add on the right of Route Constraint, and set Interface IP
Address and Restriction Type.
NOTE
l In consideration of tunnel scalability (adding nodes to tunnels), setting Restriction Type to Loosely
include is recommended.
l If creating an explicit path fails, modify the path information as prompted and create the path again.
l After source, sink, and route constraint NEs are configured for an RSVP TE tunnel, click Review
Route. NEs that the tunnel may pass through are highlighted in the physical topology.
Parameter Description
Step 5 Optional: Click Details and configure tunnel details, and QoS. For details about the parameters
in Details, see the GUI reference.
----End
Follow-up Procedure
In the dialog box displayed after the tunnel is successfully created, click Browse Trail. In the
Manage Tunnel dialog box, you can view the created tunnel. You can perform the following
operations:
NOTE
The following operations are applicable only to the tunnels for which Protocol Type is set to MPLS.
1. Choose Service > Tunnel > Manage Tunnel from the main menu.
2. In the Set Filter Criteria dialog box, set the search criteria and click Filter. The
qualified tunnels are displayed.
3. Right-click a tunnel in the tunnel list and choose Test and Check from the shortcut
menu.
4. In the LSP Ping dialog box, click Run.
5. After the check is complete, click the ... button in Details. If the values of Sent
Packets and Received Packets are the same, the tunnel is functioning properly.
l View the actual routes for the tunnel.
1. Choose Service > Tunnel > Manage Tunnel from the main menu.
2. In the Set Filter Criteria dialog box, set the search criteria and click Filter. The
qualified tunnels are displayed.
3. Select a tunnel, right-click the tunnel, and choose View LSP Topology from the
shortcut menu. The View LSP Topology progress bar is displayed.
4. After the progress bar is closed, the main topology is automatically displayed, showing
the LSP topology. The solid line stands for an active LSP and the dashed line stands
for a backup LSP.
Prerequisites
l Data synchronization must be performed for the related NE.
Procedure
Step 1 Choose Service > Tunnel > Batch Create Tunnel from the main menu.
Step 2 Set basic parameters such as Network Type, Protocol Type, and Signaling Type.
Protocol Type MPLS: If all NEs that a tunnel passes through support MPLS, set
Protocol Type to MPLS.
NOTE
Protocol Type can be set to MPLS only.
Signaling Type l RSVP TE tunnel: You need to specify only the ingress and egress
nodes for an RSVP TE tunnel. The MPLS protocol automatically
calculates a route for the tunnel. In addition, you can specify
constraint nodes to plan a specific route for the tunnel. You can
configure FRR protection and the QoS function for an RSVP TE
tunnel. Therefore, an RSVP tunnel is more flexible and safer than
an LDP tunnel.
l LDP virtual tunnel: LDP virtual tunnels can be managed but not
created. The NE automatically reports LDP virtual tunnels to the
Manage Tunnel tab page after LDP is enabled in the NE Explorer.
LDP virtual tunnels can be viewed and managed on the Manage
Tunnel tab page.
Backup Type Key tunnels on the network require that backup CR-LSPs be configured
for primary CR-LSPs.
l Hot standby: A backup CR-LSP is created immediately after a
primary CR-LSP is set up. If the primary CR-LSP fails, services will
be switched to the backup CR-LSP. If the primary CR-LSP restores,
services will be switched back to the primary CR-LSP.
l Cold standby: A backup CR-LSP is created after a primary CR-LSP
fails. If the primary CR-LSP fails, services will be switched to the
backup CR-LSP. If the primary CR-LSP restores, services will be
switched back to the primary CR-LSP.
l Disabled: A backup CR-LSP is not configured.
Step 3 Configure the tunnel list and NE list. Double-click NEs in the physical topology to select the
desired source and sink NEs and set the roles of the NEs in the NE Role column.
You can also use the following methods to select source and sink NEs:
l Method 1: Select the desired NE in the physical topology, right-click, and choose Add from
the shortcut menu.
l Method 2:
1. Click Add and choose NE. In the Select NE dialog box, select the desired NEs.
2. Click OK.
NOTE
When you set Network Type to Ring, you can click Up or Down to adjust the position of the NE in the
equipment list.
To specify the explicit or excluded NEs or interfaces for the tunnels to be created in batches base on planned
data, configure route constraints for the tunnels. Otherwise. select only the source and sink NEs for the
tunnels.
l Click Add on the right of Route Constraint. Then, select the displayed entry and click
Configure to set Interface IP Address and Restriction Type.
l If Network Type is set to Hub-Spoke, the following method can be used: Right-click the
NE in the Main Topology and choose Set Explicit Restriction > NE/Interface from the
shortcut menu. Configured route constraints are displayed on the Route Constraint tab page.
NOTE
l In consideration of tunnel scalability (adding nodes to tunnels), setting Restriction Type to Loosely
include is recommended.
l If creating an explicit path fails, modify the path information as prompted and create the path again.
Parameter Description
----End
Follow-up Procedure
l Perform the continuity check on the tunnel.
l View the actual routes for the tunnel.
Prerequisites
l You can duplicate only static tunnels and static CR tunnels.
l Layer 2 links or IP links must be configured between routers.
Context
l If the tunnel to be duplicated does not belong to a protection group, the U2000 automatically
generates two unidirectional tunnels or a bidirectional tunnel, whose direction is reverse
and share the same source and sink nodes with the tunnel to be duplicated. Perform Step
3 to duplicate the tunnel.
l If the tunnel to be duplicated belongs to a protection group, the U2000 automatically
generates the tunnel who shares the same source and sink nodes with the tunnel to be
duplicated and a new protection group that contains the two tunnels. Perform Step 4 to
duplicate the tunnels by protection group.
NOTE
If the Copy Protection Group check box is cleared, a tunnel is duplicated. In this case, you can set
Tunnel Number of Copying and other relevant parameters.
Procedure
Step 1 Choose Service > Tunnel > Manage Tunnel from the main menu.
Step 2 Right-click a tunnel to be duplicated and choose Copy from the shortcut menu. The Copy
Tunnel window is displayed.
1. Set Tunnel Number of Copying and click Refresh. The U2000 automatically generates
the specified number of tunnels that shares the same source and sink nodes.
2. Select Create Reverse Tunnel as required. By default, Create Reverse Tunnel is selected.
3. Adjust the source and sink nodes.
Select a tunnel. In the physical topology, right-click an NE and choose Set As Source or
Set As Sink from the shortcut menu.
4. Optional: In the case of a static CR tunnel, configure the route calculation for the U2000
as follows:
NOTE
To use the U2000 to automatically calculate the tunnel ID, label, and interfaces, perform this step
when creating a static CR tunnel. Otherwise, manually configure routes for the tunnel and ensure the
configuration correctness.
a. Optional: Select Auto-Calculate route. Then the U2000 automatically calculates the
routes for a tunnel after you finish Steps 2 and 3.
b. Set Restriction Bandwidth.
c. Specify route constraint nodes. Specifically, you can click Route Restriction and
specify route constraint nodes in the dialog box that is displayed. Alternatively, you
can specify the explicit and excluded nodes using shortcut menu options in the physical
topology.
d. Optional: If you do not select Auto-Calculate route, click Calculate Route to
calculate the routes for a tunnel in the U2000.
NOTE
A Layer 2 link must be configured before route calculation. For details about how to configure a
Layer 2 link, see the topology management section.
By default, the shortest route is selected from the routes that are calculated according to Restriction
Bandwidth and route constraints.
5. Select a tunnel and click Details to set the detailed parameters of the tunnel.
1. Copy Protection Group is selected by default. For details about how to duplicate a tunnel
when Copy Protection Group is not selected, see Step 3.
2. By referring to Step 3.3 and Step 3.4, adjust the source and sink nodes and configure the
automatic route calculation.
NOTE
After you change the source or sink node of a forward tunnel, the source or sink node of the reverse
tunnel changes automatically.
3. Click Details. In the right-hand pane, click Hops Information and Protection Group
Information to configure details about the tunnels and parameters relevant to the protection
group.
----End
Follow-up Procedure
l Perform the continuity check on the tunnel.
l View the actual routes for the tunnel.
Quick Navigation
Item Tunnel Protection Group MPLS Protection Ring
Creation Creation
Supported tunnels Signaling Type: Static, static CR, Signaling Type: Static CR tunnels
RSVP TE, and LDP tunnels Deployment Status: Deployed
Deployment Status: Deployed and tunnels
undeployed tunnels
Prerequisites
l Before automatic discovery of protection groups, you must ensure that the tunnel protection
groups to be discovered exist on the live network and the parameter settings are correct.
l Before creation of a protection group, you must ensure that a working tunnel and a
protection tunnel have been created.
Quick Navigation
Operation Usage Scenario
Automaticall If a tunnel protection group already exists on the NE side, perform this
y Discovering operation to restore the protection group configurations to the U2000 in order
Tunnel to monitor the protection group status and ensure its proper running.
Protection NOTE
Groups Ensure that the desired tunnel protection group exists on the live network and the
protection group parameters are correctly set. If some of the protection group
parameters are set incorrectly, for example, duplicate IP addresses of interfaces that
the tunnel passes through exist, the tunnel protection group fails to be discovered.
2. Configure basic information, such as Protection Type and Switching Mode, about the
tunnel protection group.
NOTE
l For protection groups of the 1+1 protection type, the source end sends and receives services, and
the sink end selectively receives services. If the working tunnel fails, the protection tunnel is used
to receive services to implement service switchover.
l For protection groups of the 1:1 protection type, services are transmitted on the working tunnel.
If the working tunnel fails, the protection tunnel is used to transmit services. The source end
sends services and the sink end receives services.
l Single-ended switching refers to the scenario wherein only the local end is switched but the peer
end is not notified to switch when a fault occurs at one end. Single-ended switching does not
negotiate by using negotiation packets. Therefore, it is fast and reliable.
l Dual-ended switching refers to the scenario wherein the local end is switched and the peer end
is notified to switch when a fault occurs at one end. In the case of dual-ended switching, the
come-and-go path of a service is the same. This facilitates service management.
3. Click Add. In the dialog box that is displayed, select the working tunnel and the protection
tunnel and click OK. Set Tunnel Type for the tunnels.
4. (Optional) Select a required tunnel, click Configure OAM, and then configure the OAM
information of the tunnel.
5. (Optional) Configure attributes for the tunnel protection group.
Follow-up Procedure
The tunnel protection group is successfully created. If the working tunnel fails, the protection
group automatically switches traffic to the protection tunnel. To perform a manual switchover,
choose Service > Tunnel > Manage Protection Group from the main menu. On the tab page
that is displayed, select a protection group, right-click, and choose Switch from the shortcut
menu.
NOTE
"√" indicates that the device supports the task. "-" indicates that the device does not support the task.
Dynamic L3VPN uses BGP to establish peer relationships between NEs as well as advertise
VPN routes on the backbone networks of service providers, and uses MPLS to forward VPN
packets on the backbone networks of service providers.
Prerequisites
l The MP-BGP protocol must be configured for the public network.
l If a dynamic tunnel is used to carry the L3VPN service, the IS-IS protocol must be enabled.
l The DCN must be disabled on the port of the L3VPN service.
l The configurations of the relevant NEs have been synchronized to the U2000.
Procedure
Step 1 Choose Service > L3VPN Service > Create L3VPN Service from the main menu.
Step 3 Configure service details such as basic service attributes, service access interfaces, and routing
information. For details about the relevant parameters, see the GUI reference.
Major Settings
Parameter
General Among the general attributes, the values of RD and RT are automatically
displayed as the values configured in the Service Information area. You
can change these values as needed.
The VRF Description, Routing Policy, Label Distribution Policy,
Tunnel Binding, and Max. Route Count parameters can be set.
DHCP Relay If you configure and enable a DHCP relay based on VRFs, you can
recognize and process the DHCP request packets that are transmitted from
client-side ports.
VRF QoS Set CIR and PIR as required. Deploy QoS configurations by using a QoS
profile.
NOTE
During service deployment, the selected Profile Name is delivered to NEs to
generate Local Profile Name.
You can do as follows to create a QoS profile:
l In the Select VPN QoS Profile dialog box, right-click, and choose Add Global
Profile from the shortcut menu.
l Choose Configuration > IP QoS Profile > HQoS Profile from the main menu.
On the HQoS Profile tab page, right-click, and choose Add Global Profile from
the shortcut menu.
SAI You can bind multiple interfaces and set the parameters relevant to the
interfaces.
In addition, CE Information and QoS of the interfaces are optional.
You can also click the SAI Configuration tab to add, modify, or delete an
SAI or configure the SAI QoS.
If you configure and enable a DHCP relay based on ports, you can
accurately control the interaction between the equipment connected to each
port and the DHCP server.
Route Set the basic information, such as the BGP peer. In addition, the Route
Configuration Aggregation and Route Import parameters are optional.
You can select the routing protocol and set the relevant parameters
according to actual O&M requirements.
Click on the right of a static route to copy and import static routes in
batches.
NOTE
l The private BGP protocol is configured in this step.
l The ID of the BGP instance here must be different from the ID of the MP BGP
instance.
l You must set Instance ID for RIP.
l You must set Instance ID and Area No for the OSPF.
----End
Follow-up Procedure
After the service is created, click Browse Service in the dialog box that is displayed, and view
the service in the Manage L3VPN Service window.
After the service is created and deployed, click Create Monitoring Instance in the dialog box
that id displayed to rapidly create a performance monitoring instance for the service.
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Select a configured Layer 3 virtual private network (L3VPN) service and click the Service
Link tab in the lower part.
3. Right-click the link and choose Fast Diagnosis from the shortcut menu.
4. In the VRF Ping dialog box that is displayed, click Run.
The result is Success.
NOTE
"√" indicates that the device supports the task. "-" indicates that the device does not support the task.
Prerequisites
l Data synchronization must be performed for the related NE.
l A tunnel for carrying PWs must be created.
l The DCN function of a port carrying services must be disabled if the port needs to be
exclusively used.
l A QoS policy must be created for configuring QoS if necessary.
Procedure
Step 1 Choose Service > VPLS Service > Create VPLS Service from the main menu.
A service template can be created based on service deployment requirements. For example,
you can select only the concerned parameters in the template and set default values for some
of the parameters. Then you can use the template to quickly create a service. The parameter
list contains only the selected parameters and their values.
4. Select the Networking Mode.
– Full-Mesh VPLS: All equipment is fully connected. The U2000 automatically
creates a PW between the NEs and selects an existing tunnel.
– H-VPLS: The spoke sites are fully connected to hub sites and the hub sites are
fully connected to each other, the NMS does not create PWs between NEs. You
need to establish PWs between NEs.
NOTE
ATN NEs do not support this function.
During customer creation, some personal data about users may be used. Therefore, you are
obligated to take considerable measures, in compliance with the laws of the countries concerned
and the user privacy policies of your company, to ensure that the personal data about users is
fully protected.
9. Enter the brief service description in the Remarks text box.
l Create a VPLS service of which Signal Type is set to BGP.
Adopts BGP as signaling: automatic member discovery of VPLS is implemented by
configuring VSI RTs. If you want to add or delete a PE, only the operations on one of its
peer PEs are needed. Kompella VPLS has better expansibility.
NOTE
1. Enter the name of the service to be created in the Service Name field.
2. Set Signal Type to BGP.
3. Enter the VSI name, VSI RD, and VSI RT, which are used to set common VSI
parameters of equipment. This helps to prevent setting parameters repeatedly.
4. Enter the brief VSI description in the VSI Description text box.
5. Select the name of the customer related to the service from the Customer Name drop-
down list. If no related customer is available in the drop-down list, click the ... button
next to the Search text box. In the dialog box that is displayed, select the desired
customer. If the desired customer is still unavailable, click New to create a customer.
NOTE
During customer creation, some personal data about users may be used. Therefore, you are
obligated to take considerable measures, in compliance with the laws of the countries concerned
and the user privacy policies of your company, to ensure that the personal data about users is
fully protected.
6. Enter the brief service description in the Remarks text box.
Step 3 Double-clicking NEs in the physical topology to select the desired source and sink NEs and set
the roles of the NEs in the NE Role column. You also can select the desired device from the
device list.
l If a predefined typical scenario is selected, click Add to select the PE type that meets the
scenario requirements.
l If a user-defined scenario is selected, click Add to directly select the desired PE type. PEs
are not classified for this type of scenario.
NOTE
l Deploy: Select the Deploy check box. The created VPLS service is deployed to the NE.
l Enable: After the Deploy check box is selected, you can select the Enable check box. In this case, the
created service is deployed to the NE and at the same time enabled.
Major Settings
Parameter
Tunnel Policy Indicates a tunnel policy for the tunnel that carries the VPLS service.
The tunnel policy determines the tunnel preferred for forwarding
traffic between PEs and whether to perform load balancing. You
can create the tunnel policy when selecting the VPLS service or use
the NE Explorer to create one.
Before the tunnel policy is created, the tunnel selection sequence
must be specified. If no tunnel policy is created, the LSP tunnel is
used by default and load balancing is not performed.
Major Settings
Parameter
Bound to Indicates that a service VSI is bound to an mVSI. If the created VSI
mVSI is a service VSI, it can be bound to an mVSI. By default, a service
NOTE VSI is not bound to any mVSI. This parameter is available only to
ATN NEs do service VSIs. One service VSI can be bound to only one mVSI.
not support
this function.
2. Select an NE in the NE list and then click the PW Configuration tab to set the related
PW parameters.
NOTE
Major Settings
Parameter
Signaling Dynamic: indicates that the forward and reverse labels of a PW are
Type automatically allocated by the protocol.
Uplink PW l Mesh: indicates that the sink NE on a PW does not forward the
Split Horizon packet that is sent from the source NE.
NOTE
Downlink PW ATN NEs do not support this function.
Split Horizon
l Spoke: indicates that the sink NE on a PW forwards the packet
that is sent from the source NE.
Out Tunnel
Binding Type
Major Settings
Parameter
In tunnel You can specify a tunnel interface for carrying services, the priority
of the tunnel carrying services, and the number of tunnels that
Out Tunnel participate in load balancing.
3. Select an NE in the NE list and then click the SAI Configuration tab to set the related
SAI parameters.
M Settings
aj
or
Pa
ra
m
ete
r
1 Click Create.
7 Click OK.
l Configure PTN, Hybrid MSTP, and OTN NEs under the following procedure.
Step Operation
1 In NE List, select an NE and click Details. On the VSI Configuration tab page,
set the relevant VSI parameters.
NOTE
l You need to set parameters for all the NEs in NE List.
l It is recommended that you set Split Horizon Group parameters to prevent multicast
storms. Specifically, add the PWs of NEs to split horizon groups.
3 Configure an SAI.
1. In NE List, select an NE and click the SAI Configuration tab.
2. Click Create. In the dialog box that is displayed, set the relevant information
for the SAI and click OK.
3. Click the SAI QoS tab, select an SAI, click Configure, and choose Global
QoS Policy Template or QoS Car Template. In the dialog box that is
displayed, set the relevant information for the SAI QoS.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > VPLS Service > Manage VPLS Service from the main menu.
2. Select a configured Layer 3 virtual private network (VPLS) service and click the VSI tab
in the lower part.
3. Right-click the link and choose Fast Diagnosis from the shortcut menu.
4. In the MAC Ping dialog box that is displayed, click Run.
The result is Success.
NOTE
"√" indicates that the device supports the task. "-" indicates that the device does not support the task.
Create √ √
an ATM
service
Create √ -
an ATM
IWF
service
Create a √ √
heteroge
neous
interwor
king
ATM
service
Create a √ -
manage
ment PW
Prerequisites
l DCN is disabled on the port that carries the CES service. For details, see the relevant
descriptions of the NE Explorer.
l CES service (E1 level): A CES service interface is configured, the interface mode is set to
Layer 1, and the frame format and frame mode of the interface are configured.
l A tunnel for carrying services is created.
A frame mode must be set for the interface that is used to carry a CES service.
l 30: In the E1 frame format, timeslots 1 to 15 and 17 to 31 are used to transmit service data.
l 31: In the E1 frame format, timeslots 1 to 31 are used to transmit service data.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 3 Select the source and sink NEs. The number of timeslots of the selected interfaces on the source
and sink NEs must be the same. Otherwise, the deployment may fail.
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
NOTE
According to the protection types, NEs can be configured as different roles through the shortcut
menu. Set As Switching Node indicates that the NE is configured as a hop of the multi-hop PW. For
services without protection, Set As Switching Node can be set to Working only. For services with
protection, Set As Switching Node can be set to Working or Protection.
2. Configure interface.
l In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Step 4 Optional: Click Configure PW Switch Node to add working and protection transit NEs
between the source and sink NEs.
NOTE
The protection type defines that protection switching nodes cannot be configured on services that are not
protected.
Step 5 Optional: Double-click parameters in Node and SAI Parameter to modify the settings of the
source and sink NEs displayed in Node List. To view the topology of a configured service, click
the Service Topology tab in the upper right area.
Forward Type/Reverse Type Forward Type and Reverse Type can be set
to Static Binding, Select policy,
AutoCreate Order Policy, or AutoCreate
TE Policy.
Select Forward Tunnel/Select Reverse If you select Static Binding for a tunnel, you
Tunnel can set the forward and reverse tunnels in the
Select Tunnel window. If a bidirectional
tunnel is selected as the forward tunnel, the
reverse tunnel automatically selects the
bidirectional tunnel.
You can also set the forward and reverse
tunnels by clicking the Service Topology tab
in the upper right area. Select a tunnel
between the source and sink NEs, right-click,
and choose Select Forward Tunnel or Select
Reverse Tunnel. In the dialog box that is
displayed, select the tunnel for static binding.
Step 7 Click Detail and check the configuration information in the pane that is displayed in the lower
right area.
l If the Deploy check box is not selected, the configuration data is stored only on the U2000. If the
Deploy check box is selected, the configuration data is stored on the U2000 and applied to NEs. By
default, the Deploy check box is selected.
l If the Deploy and Enable check boxes are selected, services on NEs are available only when the services
are enabled.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
3. In the Test And Check window, click Run.
The result is Success.
Prerequisites
l DCN is disabled on the UNI.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Service template You can select a template from the Service template text box and
use the template to configure a service.
If VLAN ID conflict occurs during source or sink NE configuration, information (for example, service
name) about services to which conflict VLAN ID belong is displayed during the conflict check process.
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
NOTE
According to the protection types, NEs can be configured as different roles through the shortcut
menu. Set As Switching Node indicates that the NE is configured as a hop of the multi-hop PW. For
services without protection, Set As Switching Node can be set to Working only. For services with
protection, Set As Switching Node can be set to Working or Protection.
2. Configure interface.
l In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Step 4 Optional: Double-click parameters in Node and SAI Parameter to modify the settings of the
source and sink NEs displayed in Node List. To view the topology of a configured service, click
the Service Topology tab in the upper right area.
Forward Type/Reverse Type Forward Type and Reverse Type can be set
to Static Binding, Select policy,
AutoCreate Order Policy, or AutoCreate
TE Policy.
Select Forward Tunnel/Select Reverse If you select Static Binding for a tunnel, you
Tunnel can set the forward and reverse tunnels in the
Select Tunnel window. If a bidirectional
tunnel is selected as the forward tunnel, the
reverse tunnel automatically selects the
bidirectional tunnel.
You can also set the forward and reverse
tunnels by clicking the Service Topology tab
in the upper right area. Select a tunnel
between the source and sink NEs, right-click,
and choose Select Forward Tunnel or Select
Reverse Tunnel. In the dialog box that is
displayed, select the tunnel for static binding.
Step 6 Click Detail and check the configuration information in the pane that is displayed in the lower
right area.
Step 7 Optional: Click the Service Parameter tab to set service parameters. If you set BPDU Private
Service to Yes, MTU and VLAN ID cannot be set for the Router Series NE. If multiple source
and sink nodes are configured for the service, configuring different service tags on the source
and sink nodes is supported.
Step 8 Optional: Click the PW QoS tab to configure the global template for a PW. Alternatively, click
Global Template and select a global QoS template from the drop-down list. Then set parameters.
Step 9 Optional: Click the Advanced PW Attribute tab to set advanced PW parameters. TPID and
Request VLAN are available only when PW Type is set to Ethernet Tagged Mode.
Click Configure MPLS-TP OAM. In the dialog box, set MPLS-TP OAM parameters.
NOTE
Only the PTN6900 supports this function.
l If the Deploy check box is not selected, the configuration data is stored only on the U2000. If the
Deploy check box is selected, the configuration data is stored on the U2000 and applied to NEs. By
default, the Deploy check box is selected.
l If the Deploy and Enable check boxes are selected, services on NEs are available only when the services
are enabled.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
Prerequisites
l ATM service interfaces are configured.
l If IMA interfaces are used, IMA groups must be formed.
l An ATM policy is configured.
l A tunnel for carrying the service is created.
l When creating a dynamic PW to carry the service, you must set IGP-ISIS and MPLS-LDP
protocol parameters.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
NOTE
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
NOTE
According to the protection types, NEs can be configured as different roles through the shortcut
menu. Set As Switching Node indicates that the NE is configured as a hop of the multi-hop PW. For
services without protection, Set As Switching Node can be set to Working only. For services with
protection, Set As Switching Node can be set to Working or Protection.
2. Configure interface.
l In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Step 4 Optional: Double-click parameters in Node and SAI Parameter to modify the settings of the
source and sink NEs displayed in Node List. To view the topology of a configured service, click
the Service Topology tab in the upper right area.
Forward Type/Reverse Type Forward Type and Reverse Type can be set
to Static Binding, Select policy,
AutoCreate Order Policy, or AutoCreate
TE Policy.
Select Forward Tunnel/Select Reverse If you select Static Binding for a tunnel, you
Tunnel can set the forward and reverse tunnels in the
Select Tunnel window. If a bidirectional
tunnel is selected as the forward tunnel, the
reverse tunnel automatically selects the
bidirectional tunnel.
You can also set the forward and reverse
tunnels by clicking the Service Topology tab
in the upper right area. Select a tunnel
between the source and sink NEs, right-click,
and choose Select Forward Tunnel or Select
Reverse Tunnel. In the dialog box that is
displayed, select the tunnel for static binding.
Step 6 Click ATM Link. In the dialog box, add multiple ATM connections and set the relevant
parameters.
NOTE
An ATM connection requires a source SAI and a sink SAI. The SAIs can be selected from the related drop-
down list.
If a configured VPI/VCI has been used for another service, the related message is displayed.
Step 7 Click Detail and check the configuration information in the pane that is displayed in the lower
right area.
Step 8 Optional: Click the PW QoS tab to configure a global PW template. Alternatively, select one
of the configured templates in the Global Template text box and set the relevant parameters.
Click Configure MPLS-TP OAM. In the dialog box that is displayed, set MPLS-TP OAM
parameters.
The PW control word can be changed online. In other words, Control Word can be changed
online after an ATM service is created.
NOTE
l If the Deploy check box is not selected, the configuration data is stored only on the U2000. If the
Deploy check box is selected, the configuration data is stored on the U2000 and applied to NEs. By
default, the Deploy check box is selected.
l If the Deploy and Enable check boxes are selected, services on NEs are available only when the services
are enabled.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
3. In the Test And Check window, click Run.
The result is Success.
Prerequisites
Data synchronization must be performed for the related NE.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
NOTE
According to the protection types, NEs can be configured as different roles through the shortcut
menu. Set As Switching Node indicates that the NE is configured as a hop of the multi-hop PW. For
services without protection, Set As Switching Node can be set to Working only. For services with
protection, Set As Switching Node can be set to Working or Protection.
2. Configure interface.
l In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Forward Tunnel/Reverse Tunnel You need to set the tunnel priority through
Forward Tunnel or Reverse Tunnel.
NOTE
l Click the ... button on the Management PW tab page. In the dialog box that is displayed, select
a management PW to bind it to service PWs.
l Click Configure MPLS-TP OAM. In the dialog box that is displayed, set MPLS-TP OAM
parameters.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
3. In the Test And Check window, click Run.
The result is Success.
Prerequisites
Data synchronization must be performed for the related NE.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
NOTE
According to the protection types, NEs can be configured as different roles through the shortcut
menu. Set As Switching Node indicates that the NE is configured as a hop of the multi-hop PW. For
services without protection, Set As Switching Node can be set to Working only. For services with
protection, Set As Switching Node can be set to Working or Protection.
2. Configure interface.
In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
Currently, PTN NEs in the same management domain can be used to configure unterminated trails.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Forward Tunnel/Reverse Tunnel You need to set the tunnel priority through
Forward Tunnel or Reverse Tunnel.
l Click the ... button on the Management PW tab page. In the dialog box that is displayed, select
a management PW to bind it to service PWs.
l Click Configure MPLS-TP OAM. In the dialog box that is displayed, set MPLS-TP OAM
parameters.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
3. In the Test And Check window, click Run.
The result is Success.
Creating a Management PW
This topic describes how to create a management PW. The management PW is used to transmit
packets and helps to perform active/standby switchover as well as link detection through BFD.
Prerequisites
Data synchronization must be performed for the related NE.
Context
Management PWs are created on loopback interfaces. When a large number of service PWs
exist, you can bind the service PWs to a management PW and configure BFD so that the status
of the management PW can be associated with the status of the service PWs. This helps to reduce
the quantities of BFD sessions and BFD packets and save system resources and public link
bandwidths.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
The methods of configuring the source and sink NEs are the same. Therefore, the following
describes only the method of configuring the source NE.
1. Right-click an NE in the Physical Topology and choose Select Source from the shortcut
menu.
2. Configure interface.
In the dialog box that is displayed, set the filter criteria and click Search. Then, the
interfaces that meet the filter criteria are displayed.
If no interface meets the filter criteria, you can create an interface or modify the attributes
of an existing interface.
3. Select an interface.
4. On the SAI Configuration tab page, set the SAI attributes of the service interface.
5. Click OK. Configure the sink NE or protection node by using the same method according
to the protection type. The configured roles are displayed in the node list.
6. Click Configure Source And Sink, select Unterminated on the left, specify the LSR ID
of an unterminated node, and click Add Node. In the lower portion of the window, the
unterminated source and sink NEs are displayed. Click OK.
NOTE
On a network, if NEs only at one end of a service can be managed by the U2000, select
Unterminated and set the LSR ID for the peer end of the service.
Currently, PTN NEs in the same management domain can be used to configure unterminated trails.
If Protection Type is set to PW backup protection or PW APS protection, no unterminated node
can be set.
7. Use the same method to configure the sink, protection, and transit NEs based on the
protection type.
Forward Tunnel/Reverse Tunnel Click the ... button to the right of Forward
Tunnel and Reverse Tunnel to set tunnel
policies.
Step 5 If you select Deploy, services are delivered to the NEs. If you do not select Deploy, services are
saved only on the NMS without being delivered to the NEs.
NOTE
Step 6 Optional: Click Detail, and set the parameters related to the advanced attributes of the PW.
NOTE
On the Advanced PW Attribute tab page, click Configure MPLS-TP OAM. In the dialog box that is
displayed, set MPLS-TP OAM parameters.
----End
Follow-up Procedure
verify the Configuration:
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. Select a configured PWE3 service, right-click the link and choose Test And Check from
the shortcut menu.
3. In the Test And Check window, click Run.
The result is Success.
NOTE
"√" indicates that the device supports the task. "-" indicates that the device does not support the task.
Prerequisites
ATN NEs do not support this function.
Context
Typical H-VPLS scenarios are as follows: One VPLS node accesses two PWE3 nodes. Two
VPLS nodes access one PWE3 node.
Procedure
Step 1 Choose Service > Composite Service > Create Composite Service from the main menu.
Step 2 In the General area, set basic attributes for the composite service.
1. Creation Type must be set to H-VPLS.
2. Configure BFD.
BFD for PW rapidly checks PW connectivity to detect PW faults in real time. Real-time
PW fault detection helps trigger PW switching timely to achieve carrier-class network
reliability. The procedure for enabling BFD for PW is as follows:
l Select a value from the drop-down list to enable BFD for PW.
l Click … to the right of Configure BFD to set BFD parameters.
By default, only the working PW is selected on the U2000. BFD attributes are not
associated based on PWE3 service protection types.
NOTE
Generally, BFD is configured only for the working PW to ensure network reliability under most
conditions and save bandwidth and device resources.
Add VPLS Node Click Add VPLS Node. In the dialog box that is displayed, select
VPLS service nodes. The selection methods are as follows:
l Selecting existing service nodes: Use existing NEs as service
nodes to form an H-VPLS composite service. Existing services
can be managed by the composite service in a unified manner. To
adjust or expand existing services, use this method.
On the Add Service tab page, click Filter Criteria and set filter
criteria. Then select one or more VPLS services.
l Adding new service nodes: If the existing services do not meet
requirements, use this method to configure new services on the
device and add them to an H-VPLS composite service.
Click the Add Device tab. Select one or more NEs from the
physical topology tree and click . Click OK.
Add VPLS Node- Unlike Add VPLS Node, Add VPLS Node-SAI allows you to
SAI configure VPLS SAIs on the Add Service tab page. Perform the
following operations to configure an SAI:
1. Select an NE from the physical topology tree.
2. Select an interface from the interface list.
You can click Configure to modify attributes of the selected
interface, or click Create to create an interface.
3. On the SAI Configuration tab page, set the SAI attributes of the
interface. As shown in Figure 2-1.
NOTE
The following figure takes the router GUI as an example. See the specific
GUI according to the device type.
The SAI is usually a subinterface. Do as follows to set the SAI attributes
of a subinterface: select an existing subinterface from the Subinterface
drop-down list, or enter the subinterface ID in ID to create a subinterface.
Then set a VLAN ID for the subinterface. This VLAN ID is usually the
same as the subinterface ID. You can set other attributes as required.
Add PWE3 Node Click Add PWE3 Node. In the dialog box that is displayed, select a
PWE3 service node. The selection methods are the same for Add
VPLS Node-SAI.
Repeat this operation to add more PWE3 service nodes.
Add Switch Node Click Add Switch Node. In the dialog box, select the required NE
and click to configure this NE as a PW switching point.
A PW switching point is one hop on a multi-hop PW.
NOTE
Step 4 After selecting service nodes, you can change their attributes as needed.
VSI In the service topology or service node list, select the VPLS service
node. On the VSI Configuration tab page, modify VSI attributes as
required.
NOTE
Generally, the default value provided by U2000 is used. If the default value
is different from the value planned for the live network, change the value as
required.
SAI On the SAI Configuration tab page, you can modify, add, and delete
an SAI, and set QoS attributes of the SAI.
PWE3 Service On the PWE3 Service Parameter tab page, you can set Service
Parameter Tag for a PWE3 service.
PWE3 Protection On the PWE3 Protection Parameter tab page, you can set
Parameter Protection Type for a PWE3 service.
E-Trunk In the service topology, select two service nodes of the same type
(such as two VPLS nodes), right-click, and choose E-Trunk from
the shortcut menu. In the dialog box, set E-Trunk parameters and
click OK.
E-Trunk is an extension to the Link Aggregation Control Protocol
(LACP). It controls and implements inter-device link aggregation.
E-Trunk protects PEs and links between a CE and the PEs when the
CE is dual-homed to a VPLS or PWE3 network.
NOTE
The local IP address of one node must be the peer IP address of the other
node, and Layer 3 routes must be reachable. Loopback interface addresses
are recommended.
Network Protocol In the service topology, select a service node, right-click, and choose
Network Protocol Configuration from the shortcut menu to set
network protocol parameters for the service node. The parameters
include BGP VPN4 Peer, Dynamic Route, Static Route,
Equipment MPLS/MPLS TE, and Interface MPLS/MPLS TE.
In general, network protocol parameters are set at the network
deployment stage. This configuration method is usually used to view
or adjust some parameter settings.
LDP Peer In the service topology, right-click in the blank area and choose
Configure LDP Peer from the shortcut menu.
Remote LDP peers need to be configured only for the source and
sink NEs of a PW. If a remote LDP peer has been configured for an
NE, you can only view the LDP peer configurations.
If service creation fails, modify service attributes based on the displayed error message and click
OK to create the service again.
----End
Follow-up Procedure
The status and configurations of composite services are displayed on the Composite Service
Management tab page. You can use different navigation paths on this tab page to perform end-
to-end service management.
Procedure
Step 1 Choose Service > Composite Service > Create Composite Service from the main menu.
Step 2 In the General area, set basic attributes for the composite service.
NOTE
Step 3 In the Service Component area, click Select to select the related type of service. In the window
that is displayed, select one or more services and click OK. The selected services are displayed
in both the service component list and the service topology.
NOTE
l The changes of Deployment Status, Enabling Status, and Running Status of services added to the
Service Component list area are not monitored on the Create Composite Service tab page. Therefore,
the service status displayed in the list area is not refreshed in real-time according to actual service
changes.
l If no qualified services are displayed, click Create to create a service.
Step 4 In the Connection Point area, configure the connection point for the composite service. The
configured connection point is displayed in both the connection point list area and the service
topology.
l Click Auto-Calculate to obtain the connection points automatically calculated by the
U2000 for the composite service.
l For a PWE3+L3VPN composite service, click Interface. The U2000 automatically checks
whether the L3VPN service has an SAI for interconnecting to the PWE3 service.
1. If such an SAI exists, a connection point between the PWE3 and L3VPN services is
generated and displayed in the Connection Point list.
2. If such an SAI does not exist, the U2000 keeps checking whether the NE has an L3VE
interface for interconnecting to the PWE3 service.
a. If such a L3VE interface exists, an interconnection SAI for the L3VPN service
is automatically generated based on the PWE3 SAI information.
b. If such a L3VE interface does not exist, connection point information is generated
but the L3VPN service has no connection point generated. You need to configure
a connection point for the L3VPN service.
l You can also do as follows to create the required connection points:
l Interface connection point: Select service access interfaces associated with the involved
service components. For example, if the VPLS and L3VPN service components are used
to create a composite service, select an L2VE interface associated with the VPLS service
component and an L3VE interface associated with the L3VPN service component.
l PW connection point: Select the PWs connected to the PWE3 and VPLS service
components.
5. Click OK.
If service creation fails, modify service attributes based on the displayed error message and click
OK to create the service again.
----End
Follow-up Procedure
The status and configurations of composite services are displayed on the Composite Service
Management tab page. You can use different navigation paths on this tab page to perform end-
to-end service management.
Prerequisites
The composite service to be modified exists.
Procedure
Step 1 Choose Service > Composite Service > Manage Composite Service from the main menu.
Step 2 In the Set Filter Criteria dialog box, set the filter criteria and click Filter. All the qualified
composite services are displayed in the query result area.
Step 3 Select the desired composite service and click Modify.
Step 4 Modify the following parameters of the composite service as required:
The windows for modifying and creating a composite service are similar. The only difference
is that only part of the parameters can be set in the window for modifying the composite service.
l The modifiable parameters for an H-VPLS composite service are as follows:
– Service Name
– Creation Type
– Add/Delete Service Node
– Create/Delete PW
l Except for Creation Type, other parameters can be modified for a customized composite
service. For details, see the part Creating a Customized Composite Service.
Step 5 Click OK.
----End
Result
Information about the modified composite service is displayed in the list area in the Composite
Service Management window. You can click the Topology, Service Component, and
Connection Point tabs to view details about the composite service.
network and the network bandwidth dramatically increases. If the network is interrupted for a
short period, a lot of services running on the network are affected, resulting in serious service
loss. Demands for network infrastructure reliability are increasing.
Prerequisites
Deployment Status of the service for which BFD needs to be configured is Undeployed.
Context
Tunnel BFD for LSP BFD can be used to detect data plane faults that occur on
MPLS LSPs.
L3VPN BFD for VRF BFD sessions are bound to VRFs to ensure the
transmission of BFD control packets between the
specified VRFs and to detect the link faults that occur
between VRFs. This mechanism reduces the effect of link
faults on services.
NOTE
VRF does not provide the switchover function. After BFD
detection has been configured for a VRF, BFD must be bound to
a VRRP to ensure a VRF switchover through VRRP.
PWE3 + H- BFD for PW BFD can be used to rapidly detect faults that occurs on the
VPLS PW links between local and remote PEs to support VLL
FRR and reduce the effect of link faults on services.
The U2000 supports the creation of a BFD for PW session
in static mode, that is, by manually configuring identifiers.
A combination of BF and VCCV Ping can also to be used
to ensure the connectivity of dynamic BFD PW detection.
This mechanism assists in rapid switchover of uppler-
layer services and achieves service protection.
NOTE
Procedure
Step 1 Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
Here, L3VPN services are used as an example. The procedures for configuring BFD for tunnels,
VPLS services, and PWE3 services are similar to that for L3VPN services.
The parameter settings for the detection object vary according to the type of the bound
service. The parameters except those described in the following table can use the default
values provided by the U2000 or be manually adjusted according to the planning.
NOTE
The monitoring objects supported by the tunnel, VPLS, PWE3, or L3VPN service are different and
the configuration requirements vary too. The following table describes the monitoring objects and
configuration requirements.
Local IP Address:
l If this parameter is not set, the U2000 searches
the local routing table for an outbound
interface matching the peer IP address and
uses the IP address of this interface as the
source IP address from which BFD packets
are sent.
l When both BFD and URPF are enabled, you
need to set the source IP address of BFD
packets because URPF checks the source IP
address of every received packet. The system
checks only whether the source IP address is
valid (for example, the source IP address
cannot be a multicast or broadcast address),
without carrying out any correctness check.
Therefore, you need to ensure the correctness
of the source IP address.
PWE3 BFD for VLL The parameters can use the default values
PW provided by the U2000 or be manually adjusted
according to the planning.
VPLS BFD for service The parameters can use the default values
VSI PW provided by the U2000 or be manually adjusted
according to the planning.
Tunnel BFD for TE Tunnel Interface: Select the tunnel that carries
services.
BFD for TE LSP Tunnel Interface: Select the tunnel that carries
services.
Local IP Address:
l If this parameter is not set, the U2000 searches
the local routing table for an outbound
interface matching the peer IP address and
uses the IP address of this interface as the
source IP address from which BFD packets
are sent.
l When both BFD and URPF are enabled, you
need to set the source IP address of BFD
packets because URPF checks the source IP
address of every received packet. The system
checks only whether the source IP address is
valid (for example, the source IP address
cannot be a multicast or broadcast address),
without carrying out any correctness check.
Therefore, you need to ensure the correctness
of the source IP address.
Click OK to deploy the configurations to the NE. The newly configured BFD session is displayed
in the list of the BFD Session Configuration Management window.
----End
Follow-up Procedure
l After the preceding configurations are implemented, you can learn about BFD running
conditions by checking the BFD session status. Before checking the BFD session status,
perform synchronization in the NE Explorer.
Double-click the NE in the Main Topology to open the NE Explorer. In the NE Explorer,
choose BFD Management > Service Detection Configuration > VRF Detection
Configuration from the navigation tree. On the VRF Detection Configuration tab page,
right-click in the blank area and choose Synchronize from the shortcut menu.
l As described earlier, the measure taken based on the BFD session status is determined by
the upper-layer application, which is usually VRRP. For details, see 2.8.2 Configuring
VRRP.
Prerequisites
Deployment Status of the service for which VRRP needs to be configured is Undeployed.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Here, PWE3 services are used as an example. The procedures for configuring VRRP for tunnels,
VPLS services, and L3VPN services are similar to that for PWE3 services.
Step 2 Filter services.
In the Set Filter Criteria dialog box, set filter criteria and click Filter. All the qualified services
are displayed in the query result area.
Step 3 Open the VRRP creation window.
1. Select the desired PWE3 service from the service list, right-click, and choose Configure
VRRP from the shortcut menu.
2. In the Set Filter Criteria dialog box, set filter criteria and click OK. All the VRRPs meeting
the filter criteria are displayed in the query result area.
3. In the VRRP-Based Detection Configuration Management window, click Create.
Step 4 Set VRRP detection parameters.
In the Create VRRP dialog box, set the relevant parameters.
On the Metro Ethernet, VRRP runs between NPEs. BFD between NPEs is called peer BFD, and BFD
between the NPE and UPE is called link BFD. Peer BFD and link BFD are used to detect the link and
NE faults between NPEs and between the NPE and UPE respectively. Peer BFD and link BFD directly
affect the status of a backup group without modifying the priority of the backup group. As a result, in
non-preemption mode, the priority of a backup router may be higher than that of a master router after
peer BFD and link BFD are configured.
----End
Result
View the following information in the VRRP-Based Detection Configuration Management
window:
l Working NE, Working State, Protection NE, and Protection State in the list to learn
about all VRRP backup groups configured for the PWE3 service and the master and backup
states of NEs in a VRRP backup group.
l Service Component Associated with VR tab page on which service components for
tracking VRs are displayed. These service components determine their own active/standby
states by tracking the VR status.
l VR Tracking Object tab page on which all objects (usually interfaces, BFD sessions, and
OAM) monitored by the VRRP backup group and priority adjustment values (for example,
10) are displayed. The VRRP backup group adjusts priorities based on the status of
monitored objects and determines whether to perform a master/backup switchover based
on the adjusted priorities.
ARP two-node hot backup can be configured for L3VPN services and back up ARP information
between two NEs running VRRP to ensure ARP information synchronization between the master
and backup NEs. After a VRRP active/standby switchover is complete, Downstream traffic is
transmitted properly without learning of MAC addresses in ARP entries after a master/backup
VRRP switchover is performed. This effectively resolves the packet loss problem that occurs
because ARP information is not obtained in time after a switchover is complete.
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Select the desired L3VPN service and click the SAI.
3. Click Create.
4. Select the desired NE and L3VE subinterface from the physical topology tree, and click
the ... button on the right of Remote Backup Policy.
A remote backup policy can be created only using the NE Explorer.
5. Click OK.
6. Perform Steps 3 through 6 on the peer NE.
Procedure
Step 1 Choose Administration > NE Communicate Parameter > NE Telnet/STelnet Template
Management from the main menu.
Step 2 In the dialog box that is displayed, click Create.
NOTE
In the scenario where only part of the parameters of a default template or created template need to be modified,
select the desired template, and then modify associated parameters in the Details area.
Step 3 In the dialog box that is displayed, select the desired protocol type, set Template Name, and
then click OK. The following figure shows how to create a STelnet template.
Add a template record in the Telnet/STelnet Template Information area.
Step 4 Select the created template. Then, set associated parameters in the Details area.
----End
Prerequisites
l The related parameters, such as the user name and password, must be set on equipment.
NOTE
The device login header cannot contain special characters "#", "]", ">". Otherwise, the U2000 fails
to verify Telnet/STelnet parameters.
l The Telnet/STelnet template must be configured on the U2000.
Context
Security authentication modes are not adopted for the Telnet mode. Packets are transmitted
through TCP in plain text, which brings security risks. The U2000 adopts STelnet to reduce
security risks, using SSH features to ensure security and effective authentication.
Procedure
Step 1 In the Main Topology, select the equipment whose Telnet or STelnet parameters need to be set.
NOTE
You can also right-click the selected equipment and then choose Set NE Telnet/STelnet Parameter from
the shortcut menu.
Step 4 In the Select Telnet/STelnet Template dialog box, select the template to be used, and then click
OK.
----End
Context
In the U2000, you can configure one Telnet parameter template and one STelnet parameter
template. If required, you can manually modify the configured templates to set the Telnet/
STelnet parameters for equipment.
NOTE
The device login header cannot contain special characters "#", "]", ">". Otherwise, the U2000 fails to verify
Telnet/STelnet parameters.
Procedure
Step 1 In the Main Topology, select the equipment whose Telnet/STelnet parameters need to be
modified.
NOTE
l You can also right-click the selected equipment and then choose Set NE Telnet/STelnet Parameter
from the shortcut menu.
Step 3 In the Details group box of the Device Telnet/STelnet Parameter Management dialog box,
modify Telnet/STelnet parameters manually.
l To modify Telnet parameters:
Set Protocol Name to Telnet.
l To modify STelnet parameters:
Set Protocol Name to STelnet.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, choose Device Management > System Information.
Step 3 On the System Information tab page, set or view system information.
NOTE
Step 4 Optional: Click Synchronize to refresh system information displayed on the U2000.
----End
Context
Ensure that the NE IP address set on the NMS is the same as the actual IP address of the NE.
Otherwise, the communication fails.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Device Management > NE IP Address Management from the service tree.
Step 3 On the NE IP Address Management tab page, the original IP address of the NE is displayed.
You can change the NE IP address stored on the NMS through New IP Address to restore the
communication.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 Optional: If you are currently visiting other tab pages on the NE Explorer tab page, you can
choose Device Management > NE Panel from the service tree to access the NE Panel tab page.
NOTE
l The colors of the board indicate the running status of the board.
l The alarm indicator color is determined by the highest alarm severity of the board and its ports.
l The color of a port indicates the status of the port. For the colors of specific ports, see the legend on
the right of the panel.
l When the administrative status of a port is Down, the following situations occur:
l If no alarm is generated on the port, the color of the port is gray.
l If there is an alarm on the port, the color of the port depends on the severity level of the alarm.
l When the administrative status of a port is Up, the following situations occur:
l If no alarm is generated on the port, the color of the port is green.
l If there is an alarm on the port, the color of the port depends on the severity level of the alarm.
l When the administrative status of a port is Up, the running status of the port is Down, and no alarm
is generated on the port, the port color is the same as the color for critical alarms.
l When a board is inserted into a slot, the slot blinks in blue. After being successfully registered, the
board is displayed on the NE panel.
l If no flexible plug-in board is inserted, the board is displayed as blank. On the NE panel, no subboard
can be selected.
Step 3 When you select components on the panel, you can view the detailed information about the
components through the related tabs on the lower part of the panel.
l When you select the board, the Board Information tab page displays the detailed
information about the board. If the board has subboards or ports, you can view the detailed
information about the subboards or ports through the Subboard Information tab or the Port
Information tab. If you double-click the board, the Port Information tab page is displayed.
l When you select a port, the port record is displayed on the Port Information tab page. Right-
click the port record. The shortcut menu options are the same as those displayed when you
right-click a port on the panel.
Step 4 Optional: On the Board Information, Subboard Information, and Port Information tab
page, you can right-click in the table heading in the query result area to select which parameters
are displayed.
l Method one: Right-click in the table heading and select parameters to be displayed. You
can select only one parameter each time; therefore, this method is applicable for minor
adjustment.
l Method two: Right-click in the table heading and choose Customize from the shortcut
menu. In the dialog box that is displayed, select parameters to be displayed. This method
is applicable for selecting parameters to be displayed at a time.
----End
Resetting a Board
This topic describes how to reset a board. When the software of a board needs to be updated or
a fault occurs on a board, you can reset the board.
Prerequisites
Telnet or STelnet parameters must be set on the equipment and the equipment information must
be synchronized to the NMS.
Context
NOTICE
l In most cases, do not reset a board, because the network related to the device will be Down
for a while.
l Back up the key data before resetting the board.
l When you reset a board, do not perform hot swap for the board.
l When the active control board is reset, the equipment restarts without powering off the CPU
of the board. If the equipment has the standby control board, the equipment performs the
active/standby switchover after the board is reset.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 Optional: If you are currently visiting other tab pages on the NE Explorer tab page, you can
choose Device Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Select the board to be reset on the NE panel, right-click it, and then select Reset Board.
----End
Follow-up Procedure
If the status of the board is still offline after the board is reset for 10 minutes, click
Synchronize in the lower part of the NE panel to manually synchronize the status of the NE
panel. The status of the board cannot be refreshed when the configurations of other modules are
being synchronized.
Resetting a Subboard
This topic describes how to reset a subboard. When an abnormality occurs during the running
of a subboard, it is recommended that you reset the subboard.
Prerequisites
Telnet or STelnet parameters must be set on the NMS for accessing the device and device
configurations are synchronized to the NMS.
Context
NOTICE
l In normal cases, do not reset a subboard, because this operation may cause the network related
to the device to go Down for a while.
l Back up the key data before resetting the subboard.
l When you reset a subboard, do not hot swap the subboard.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 Optional: If you are currently visiting other tab pages on the NE Explorer tab page, you can
choose Device Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click the board of the subboard on the NE panel and choose Reset Subboard from the
shortcut menu.
----End
Follow-up Procedure
If the subboard still cannot be operated 10 minutes after it is reset, that is, no subboard is displayed
on the NE panel, click Synchronize in the lower part of the NE panel to manually refresh the
status of the NE panel. The status of the subboard cannot be refreshed when the configurations
of other modules are being synchronized.
Prerequisites
l The standby control board must be available on the equipment.
l Telnet or STelnet parameters must be set on the equipment and the equipment information
must be synchronized to the NMS.
Context
NOTICE
To ensure the normal forwarding of data and reduce the impact on services during the active/
standby switchover on the equipment, enable GR of various routing protocols on the equipment
and its neighboring equipment, set the active/standby switchover parameters such as the default
slot ID of the standby control board on the equipment, enable the forcible active/standby
switchover function on the equipment, and configure the active control board and the standby
control board to automatically synchronize information. For details, see the GR configuration
in the Configuration Guide-Reliability.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 Optional: If you are currently visiting other tab pages on the NE Explorer tab page, you can
choose Device Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click the desired standby control board in the NE panel and choose Switch Active/
Standby Card from the shortcut menu.
----End
Prerequisites
The equipment must be configured with Telnet or STelnet parameters, and equipment
information must be synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Device Management > NE Panel from the service tree.
Step 3 On the NE Panel, select the port to be viewed, right-click, and then choose Object Attribute
from the shortcut menu.
NOTE
You can also click the Port Information tab. On the tab page, select the port to be viewed, right-click, and
then choose Object Attribute from the shortcut menu.
Step 4 In the Object Attribute dialog box, view basic port information and other associated
information.
----End
Context
l When an interface is idle or not connected to any cable, you need to disable the interface
to avoid the interface abnormality caused by interference.
l When an interface has subinterfaces, the interval between enabling and disabling the
interface must at least be 15 seconds.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 If you are currently visiting other tab pages on the NE Explorer tab page, you can choose Device
Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click an interface on the NE panel, and then perform either of the following operations:
l Choose Up from the shortcut menu to enable the interface.
l Choose Down from the shortcut menu, and then click OK in the dialog box that is displayed
to disable the interface.
----End
Monitoring NE Status
This topic describes how to monitor NE status. You can monitor the status of an NE by viewing
the system resource usage of the NE, storage space of the NE, and alarms of the NE. The
following takes the operation of viewing the version of an NE as an example to describe how to
monitor NE status.
Function Description
Function Description
View NE Version After selecting this function, you can view the
version of the NE in the dialog box that is
displayed.
View NE Board and SubCard After selecting this function, you can view the
card and subcard of the NE in the dialog box
that is displayed.
View NE Clock After selecting this function, you can view the
clock of the NE in the dialog box that is
displayed.
View NE Storage Space After selecting this function, you can view the
storage space of the NE in the dialog box that
is displayed.
View NE System Resource Usage After selecting this function, you can view the
system resource usage of the NE in the dialog
box that is displayed.
View NE Power Supply and Fan After selecting this function, you can view the
power supply and fan of the NE in the dialog
box that is displayed.
View NE Card Power Rating After selecting this function, you can view the
rate power of a card in the dialog box that is
displayed.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 If you are currently visiting other tab pages on the NE Explorer tab page, you can choose Device
Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click a shelf on the NE panel and choose View NE Version from the shortcut menu.
NOTE
Step 4 Optional: In the View NE Version dialog box, click Save As to save the queried NE version
information to a local NE.
----End
Function Description
View Board Information After selecting this function, you can view the
information about the board in the dialog box
that is displayed.
View Board CPU After selecting this function, you can view the
CPU usage of the board in the dialog box that
is displayed.
View Board Memory After selecting this function, you can view the
memory usage of the board in the dialog box
that is displayed.
View Board Voltage After selecting this function, you can view the
voltage of the board in the dialog box that is
displayed.
Function Description
View Board Temperature After selecting this function, you can view the
temperature of the board in the dialog box that
is displayed.
View Board Log After selecting this function, you can view the
logs of the board in the dialog box that is
displayed.
View Historical Resources After selecting this function, you can view
historical resources of the selected board in
the dialog box that is displayed.
NOTE
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 If you are currently visiting other tab pages on the NE Explorer tab page, you can choose Device
Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click a board in the NE panel and choose View Card Information from the shortcut
menu.
Step 4 Optional: In the View Board Information dialog box, click Refresh to refresh board
information.
Step 5 Optional: In the View Board Information dialog box, click Save As to save the queried board
information to a local device.
----End
Function Description
Object Attribute After selecting this function, you can view the
attribute of the object in the dialog box that is
displayed.
Function Description
View Port Information After selecting this function, you can view the
information about the port in the dialog box
that is displayed.
View Current Port Configurations After selecting this function, you can view the
current configuration of the port in the dialog
box that is displayed.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
The NE Panel tab page is displayed by default.
Step 2 If you are currently visiting other tab pages on the NE Explorer tab page, you can choose Device
Management > NE Panel from the service tree to access the NE Panel tab page.
Step 3 Right-click a port in the NE panel and choose View Port Information from the shortcut menu.
Step 4 Optional: In the View Port Information dialog box, click Refresh to refresh port information.
Step 5 Optional: In the View Port Information dialog box, click Save As to save the queried port
information to a local device.
----End
Procedure
Step 1 Right-click the cluster equipment in the Main Topology and choose NE Explorer from the
shortcut menu.
Step 2 Choose Device Management > NE Panel from the service tree.
Step 3 On the Subrack Information tab page, view the following parameters: Name, Subrack No.,
Software Version, Serial No., and Status.
Subrack information cannot be saved. Instead, you can refresh shelf information for query.
----End
Prerequisites
l Telnet or STelnet parameters must have been set for the NE, and NE information must have
been synchronized to the U2000.
l The user termination mode cannot be configured for Ethernet and Eth-Trunk interfaces. If
this mode is configured for an Ethernet or Eth-Trunk interface, the global performance
statistics function for subinterfaces does not take effect for relevant subinterfaces.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Device Management > Global System Configuration from the service tree.
Step 3 In the dialog box that is displayed, view the progress of global NE configuration synchronization.
NOTE
If a message indicating a synchronization failure is displayed, click Details. The failure causes of
configuration items are displayed. In the query result area, no values are displayed for the parameters
mapping the configuration items failed in synchronization.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Device Management > Historical Resources from the service tree.
NOTE
Alternatively, select a system control board on the NE Panel, right-click, and then choose View Historical
Resources from the shortcut menu to access the Historical Resources tab page.
Filter criteria for historical resources include Name, Resource Type, Type Description, Serial
Number, BOM ID, Shelf No., Slot No., Subslot No., Description, Inserted at, and Removed at.
Resource Type can be set to Board, Subboard, or All.
Inserted at and Removed at can be set according to the DST.
----End
Context
After historical resources are exported, the associated data is not deleted from the database. You
can query the data on the client.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Device Management > Historical Resources from the service tree.
NOTE
Alternatively, select a system control board on the NE Panel, right-click, and then choose View Historical
Resources from the shortcut menu to access the Historical Resources tab page.
Step 3 On the Historical Resources tab page, set filter criteria and click Query.
Step 5 In the Save dialog box, set the path, name, and format of the file to be saved.
----End
Prerequisites
The features of related interface modules must be synchronized to the NMS.
Context
l If a physical interface is idle and not connecting to any cable, disable this interface to prevent
interface malfunctions caused by interference.
l The loopback and Null interfaces cannot be enabled or disabled.
l Exercise caution when you enable or disable an interface. In some situations, interface
parameters such as the working mode take effect only after the interface is enabled or
disabled.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Interface Management, and then click Interface Information.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 5 In the query result area, select the interface to be enabled or disabled, and perform either of the
following substeps as needed:
l Right-click the interface and choose Up from the shortcut menu to enable the interface.
l Right-click the interface and choose Down from the shortcut menu. In the dialog box that is
displayed, click View Associated Service. On the Service Information tab page, view
service information to understand the impact of this operation on services. To disable this
interface, select Understand impact of the operation in the dialog box that is displayed and
click OK.
----End
Prerequisites
The features of related interface modules must be synchronized to the NMS.
Context
l No IP address can be set for a NULL interface or Layer 2 interface.
l The trunk interface, VLAN interface, loopback interface, or Ethernet sub-interface,
however, cannot borrow the IP address of another interface.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Interface Management, and then click Interface Information.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
If the peers of virtual connections are on different network segments, using only one master IP address
for the local interface cannot meet the communication requirements. Click Add to set a secondary IPv4
address to solve this problem.
NOTE
If the interface is a Layer 2 interface, the IP address of the interface cannot be set.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l Before monitoring real-time performance or querying performance data, ensure that the
Simple Network Management Protocol (SNMP) version is SNMPv2c or higher when you
create NEs. Otherwise, the U2000 cannot properly collect performance data.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 To monitor the real-time performance of Ethernet interfaces, Ethernet subinterfaces, loopback
interfaces, tunnel interfaces, and VLAN interfaces, perform the following steps:
Choose Interface Management > Interface Information from the service tree to monitor the
real-time performance of all the interfaces that support this function.
Step 3 In the query result area, right-click the interface to be monitored and choose Monitor Real-
Time Performance from the shortcut menu.
In the dialog box that is displayed, view the graph of real-time board performance.
----End
Configuring an E1 Interface
This topic describes how to configure an E1 interface. E1 interfaces are used to implement
multiple-channel communication in a system where a single physical channel consists of
multiple logical channels. If an interface is required to communicate with the peer NE, an E1
interface must be configured.
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support E1 interfaces and the E1 interface to be configured must exist on the
NE.
Context
To enable the U2000 to correctly display information about operation errors, perform the
following operations:
1. Run the system-view command to access the system view.
2. Run the snmp extend error-code enable command to enable the U2000 to correctly
display error codes.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Click Condition. In the Filter Criteria dialog box, set query conditions, and then click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 7 In the Configure E1 Interface dialog box, set the related parameters.
l Click the General tab. Then, set Description.
l Click the Physical Feature tab. Then, set Basic, Monitor Alarm Threshold and Timeslot
Configuration.
Step 8 Click OK.
In the query result area, information about the modified interface is displayed.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support Ethernet interfaces and the Ethernet interface to be configured must
exist on the NE.
Context
l When you configure an Ethernet interface, all interface parameters except the interface IP
address have default values. If you need to change the values, ensure that the new values
are consistent with those on the peer NE.
l After an Ethernet subinterface is added, the main interface cannot be configured.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 7 In the Configure Ethernet Interface dialog box, set parameters as needed.
l Click the General tab. Then set Description.
l Click the Physical Feature tab. Then set Working Mode, Negotiation Rate, Medium
Mode, Auto-Negotiation, Delay Time, Up Hold, Down Hold, Byte Overhead, Monitor
Alarm Threshold, and Transfer Mode.
l Click the Ethernet Feature tab. Then set User Termination Mode, VLAN Swap, and
interface layer.
l Click the IPv4 Address tab. Then set parameters such as the IPv4 address.
l Click the Local CE tab. Then set the IP address, MAC address, and broadcast function of
the PE's Ethernet interface connected to the CE.
NOTE
If the Ethernet interface is a Layer 2 interface, no IP address can be set for the interface.
If the Ethernet interface is a Layer 3 interface, IPv4 addresses can be set for the interface.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The equipment must support Ethernet interfaces and Ethernet subinterfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and select Create Subinterface >
Ethernet Subinterface.
NOTE
After creation, you can also select the subinterface to be configured in the query result area and click
Configure to configure the created subinterface.
Step 4 In the Create Ethernet Subinterface dialog box, set the related parameters as required.
l Click the General tab. Then, set Main Interface Name, Subinterface No., and
Description.
NOTE
l By default, the main interface name is the name of the currently selected main interface. You can
click the ... button to re-select the main interface.
l To enable the performance measurement function on the subinterface, select Statistic, and choose
to set Statistic Interval Time as required.
l Click the Subinterface Feature tab. Then, do as follows to set Access Mode of the
subinterface:
– If User Termination Mode is not set for the main interface, you can set Access
Mode to either of the following values for the subinterface:
– VLAN Encapsulation (Subinterface is set to VLAN encapsulation.)
– Flexible Access
– If User Termination Mode is set for the main interface, you can set Access Mode to
either of the following values for the subinterface:
– VLAN Termination (Stacking or Dot1q Termination can be choosed.)
– Flexible Access
l Click the IPv4 Address tab. Then, set the IPv4 address of the subinterface.
l Click the Local CE tab. Then, set IPv4 and MAC addresses for the PE's interface connecting
to the CE, and enable the broadcast function.
Information about the new subinterface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support Eth-Trunk interfaces.
l Before you create an Eth-Trunk interface, link-layer parameters must have been set for all
member interfaces and links must function properly.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Eth-Trunk Interface.
Step 4 In the Create Eth-Trunk Interface dialog box, set parameters as needed.
l Click the General tab. Then, set Interface No. and Description.
l Click the Physical Feature tab. Then, set User Termination Mode, VLAN Swap,
interface layer, Working Mode, Load Balancing Mode, Minimum Up Links, Maximum
Links Affecting Bandwidth, and LACP Feature.
l Click the Member Interface tab. Then, add member interfaces.
l Click the IPv4 Address tab. Then, set parameters such as the Internet Protocol Version 4
(IPv4) address.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The equipment must support Eth-Trunk interfaces and Eth-Trunk subinterfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create, and then select Create Subinterface >
Eth-Trunk Subinterface from the drop-down list.
NOTE
After creation, you can also select the subinterface to be configured in the query result area and click
Configure to configure the created subinterface.
Step 4 In the Create Eth-Trunk Subinterface dialog box, set parameters as required.
l Click the General tab. Then, set Main Interface Name, Subinterface No. , and
Description.
NOTE
l By default, the main interface name is the name of the currently selected main interface. You can
click the ... button to re-select the main interface.
l To enable the performance measurement function on the subinterface, select Statistic, and choose
to set Statistic Interval Time as required.
l Click the Subinterface Feature tab. Then, do as follows to set Access Mode of the
subinterface:
– If User Termination Mode is not set for the main interface, you can set Access
Mode to either of the following values for the subinterface:
– VLAN Encapsulation
– Flexible Access
– If User Termination Mode is set for the main interface, you can set Access Mode to
either of the following values for the subinterface:
– VLAN Termination
– Flexible Access
l Click the IPv4 Address tab. Then, set parameters such as the IPv4 address.
l Click the Local CE tab. Then, set IPv4 and MAC addresses for the PE's interface connecting
to the CE, and enable the broadcast function.
Information about the new subinterface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support IMA groups.
Context
An IMA group is a logical link consisting of one or more links. It is used to provide a higher
bandwidth that is approximately equal to the sum of all the member links' bandwidths.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > IMA Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create IMA Interface dialog box, set the related parameters.
l Click the General tab. Then, set Interface No. and Description.
l Click the Physical Feature tab. Then, set Transmission Clock Mode, Differential Delay,
Frame Length, Min. Active Links, and ATM Interface Type.
l Click the Member Interface tab. Then, add member interfaces.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support IMA groups.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Subinterface > IMA Subinterface.
NOTE
After creation, you can also select the subinterface to be configured in the query result area and click
Configure to configure the created subinterface.
Step 4 In the Create IMA Subinterface dialog box, set the related parameters.
l Click the General tab. Then, set Main Interface Name, Subinterface Type, Subinterface
No., and Description.
l Click the PVC/PVP tab. Then, set the related PVC/PVP parameters for the IMA subinterface.
Information about the new subinterface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Loopback Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Loopback Interface dialog box, set parameters as needed.
l Click the General tab. Then, set Interface No. and Description.
l Click the IPv4 Address tab. Then, set parameters such as IPv4 Address.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support serial interfaces and the serial interface to be configured must exist
on the NE.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 7 In the Configure Serial Interface dialog box, set the related parameters.
l Click the General tab. Then, set Description.
l Click the Serial Feature tab. Then, set Link Layer Protocol, CRC Length, Negotiated
Packet Interval, and ATM Interface Type.
----End
Prerequisites
A serial subinterface encapsulated in ATM can be created only when Link Layer Protocol is
set to ATM.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Subinterface > Serial Subinterface.
NOTE
After creation, you can also select the subinterface to be configured in the query result area and click
Configure to configure the created subinterface.
Step 4 In the Create Serial Subinterface dialog box, set the related parameters.
l Click the General tab. Then, set Main Interface Name, Subinterface Type, Subinterface
No., and Description.
l Click the PVC/PVP tab. Then, set the related PVC/PVP parameters for the subinterface.
Information about the new subinterface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support tunnel interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Tunnel Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Tunnel Interface dialog box, set parameters as needed.
l Click the General tab. Then, set Interface No. and Description.
NOTE
To enable the performance measurement function on the interface, select Statistic, and choose to set
Statistic Interval Time as required.
l Click the IPv4 Address tab. Then, set parameters such as IPv4 Address and Negotiated
IPv4 Address.
Step 5 Optional: Click Apply. The interface is added.
Information about the new interface is displayed in the query result area.
You can add more interfaces by repeating the preceding steps.
Step 6 Click OK.
Close the dialog box.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l A VLAN must have been created for the NE.
l The NE must support VLAN interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Vlan Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Vlan Interface dialog box, set parameters as needed.
l Click the General tab. Then, set Interface No. and Description.
l Click the Physical Feature tab. Then, set Bandwidth.
l Click the IPv4 Address tab. Then, set parameters such as IPv4 Address.
Step 5 Optional: Click Apply. The interface is added.
Information about the new interface is displayed in the query result area.
You can add more interfaces by repeating the preceding steps.
Step 6 Click OK.
Close the dialog box.
----End
Creating an MP Interface
This topic describes how to create an MP interface. Multiple bound PPP links can be bound as
an MP interface to increase bandwidth. MP can be applied to PPP-capable interfaces such as
serial interfaces and low-speed POS interfaces. MP supports packet fragmentation. Fragmented
packets are sent to the same destination through multiple PPP links of an MP interface.
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l NEs must support MP interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > MP Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l PVCs must have been configured for the suninterfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create, and then select Create Main Interface
> Atm-Bundle Interface from the related drop-down list.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Atm-Bundle Interface dialog box, set the related parameters as required.
l Click the General tab. Then, set Interface No. and Description.
l Click the Member Interface tab page to add member interfaces.
Information about the new interface is displayed in the query result area.
----End
Creating a VE Interface
This topic describes how to create a Virtual Ethernet (VE) interface. If Point-to-Point Protocol
over Ethernet (PPPoE) or Internet Protocol over Ethernet (IPoE) packets need to be transmitted
over an Asynchronous Transfer Mode (ATM) network, VE interfaces must be configured to
implement interworking between PPPoE and ATM or between IPoE and ATM. VE interfaces
can also be used to access a Layer 2 Virtual Private Network (L2VPN), Virtual Private LAN
Segment (VPLS), and Layer 3 Virtual Private Network (L3VPN), or to perform Layer 3 packet
forwarding.
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support VE interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > VE Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create VE Interface dialog box, set the related parameters.
l Click the General tab. Then set Interface No. and Description.
l Click the IPv4 Address tab. Then, set parameters such as IPv4 Address.
Information about the new interface is displayed in the query result area.
----End
Creating a VE Subinterface
This topic describes how to create a VE subinterface. A VE interface supports multiple logical
subinterfaces. These logical subinterfaces use physical layer and link layer configuration
parameters of the VE interface, and have their own network layer configuration parameters.
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The equipment must support VE interfaces and VE subinterfaces.
l The main interface must be configured with User Termination Mode.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create, and then select Create Subinterface >
VE Subinterface from the related drop-down list.
NOTE
After creation, you can also select the subinterface to be configured in the query result area and click
Configure to configure the created subinterface.
Step 4 In the Create VE Subinterface dialog box, set the related parameters as required.
l Click the General tab. Then, set Subinterface No. and Description.
NOTE
To enable the performance measurement function on the subinterface, select Statistic, and choose
to set Statistic Interval Time as required.
l Click the Subinterface Feature tab. Then, set the encapsulate mode or termination mode
for the subinterface.
l Click the IPv4 Address tab. Then, set parameters such as the subinterface IPv4 address.
Information about the new subinterface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l The NE must support Dsl-Group interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > DSLGroup Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create DslGroup Interface dialog box, set the related parameters.
l Click the General tab. Then set Interface No. and Description.
l Click the Physical Feature tab. Then set Basic Information and IMA Group Feature.
l Click the Member Interface tab. Then set member interface.
l Click the Bound VE tab. Then set VE interface.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l NEs must support Global-MP-Group interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Global-MP Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Global-MP Interface dialog box, set parameters as required.
l Click the General tab, and then set Interface No. and Description.
l Click the MP Feature tab and set related parameters.
Information about the new interface is displayed in the query result area.
----End
Prerequisites
l The features of related interface modules must be synchronized to the NMS.
l NEs must support Cpos-Trunk interfaces.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click the Create drop-down button and choose Create
Main Interface > Cpos-Trunk Interface.
NOTE
After creation, you can also select the interface to be configured in the query result area and click
Configure to configure the created interface.
Step 4 In the Create Cpos-Trunk Interface dialog box, set parameters as required.
l Click the General tab, and then set Interface No. and Description.
l Click the DS1 List tab and set related parameters.
l Click the Member Interface tab and set member interfaces.
Information about the new interface is displayed in the query result area.
----End
clearly displayed. This enhances the relationship between the interface and the service feature
and improves the U2000 usability.
Prerequisites
The features of related interface modules must be synchronized to the NMS.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 7 On the Protocol tab page, click the Create drop-down button and choose MPLS, ISIS, or
OSPF.
In the dialog box that is displayed, set the related parameters.
----End
Prerequisites
The features of related interface modules must be synchronized to the NMS.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
----End
Result
Information about the configured QoS is displayed in the result area on the related tab page.
Prerequisites
The features of related interface modules must be synchronized to the NMS.
Procedure
Step 1 Right-click an NE in the topology view and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 Optional: Click Condition. In the Filter Criteria dialog box, set query conditions, and then
click OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
Step 7 On the ICMP tab page, select ICMP Redirect Send Enable and ICMP Host Unreachable
Send Enable.
NOTE
Generally, ICMP redirection packets and ICMP host unreachable packets are sent properly. If network
traffic is heavy, NEs may send may ICMP packets, which increases network traffic. Especially, if a
malicious attack is launched, network congestion is increased. Therefore, it is recommended that the
preceding two check boxes be cleared to reduce network traffic and prevent malicious attacks.
----End
Prerequisites
Telnet or STelnet parameters must be set on the equipment and the equipment information must
be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > VTY Service from the service
tree.
Step 3 On the VTY Service tab page, set Max. Available VTYs with up and down arrows. Click
Apply.
Step 4 Select a VTY record in the VTY service view. Set VTY parameters.
----End
Prerequisites
Telnet or STelnet parameters must be set on the equipment and the equipment information must
be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > FTP Service from the service
tree.
Step 3 On the FTP Service tab page, determine whether to enable FTP Server, set FTP Server
Timeout and VRF Name. If FTP Server is disabled, you cannot set FTP Server Timeout.
NOTE
If the U2000 manages NEs in inband VPN networking mode, the VRF name must be specified.
----End
Prerequisites
The features of local user must be synchronized to the NMS.
Context
A maximum of 1000 local user accounts can be configured on each managed U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Local User from the service tree.
Step 3 On the Local User tab page, set Number of Password Retries.
Step 4 Right-click on the Local User tab page and choose Create from the shortcut menu.
Step 5 In the Create Local User dialog box, set the related parameters.
----End
Prerequisites
l The selected equipment must support the log service function on the U2000.
l Telnet or STelnet parameters must be set on the equipment and the equipment information
must be synchronized to the U2000.
l The Syslog source interface and its IP address must be known.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Syslog Service from the service
tree.
Step 4 Click Enable or Disable to change the service status of the Syslog source interface.
NOTE
If the Syslog source of the host is in use, you cannot select the Syslog source interface from the drop-down
list box. The displayed status button is Disable. Click Disable to disable the log source. Then, you can
select the Syslog source interface from the drop-down list box. The status button that is displayed changes
to Enable.
Step 5 When the Syslog source is disabled, select the source interface for sending Syslog files from the
drop-down list box, and then click Enable.
----End
Prerequisites
The IP address of the log host must be known.
Context
To view NE Syslog using the U2000, set Log Host IP Address to U2000 Server IP Address
to configure the U2000 server as the NE Syslog receiver.
NOTE
The system supports the configuration of a maximum of eight log hosts to realize backup among log hosts.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Syslog Service from the service
tree.
Step 3 Right-click on the Syslog Service tab page and choose Create from the shortcut menu.
NOTE
If the U2000 manages NEs in inband VPN networking mode, the VRF name must be specified.
Step 4 In the Create Log Host dialog box, set the related parameters.
If more than one log host is created, the Create Log Host progress bar is displayed. After all
the log hosts are created, click OK.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Syslog Service from the service
tree.
Step 4 In the Advanced Configuration dialog box, set the parameters in the Log buffer and Log
File areas.
----End
Prerequisites
The trap source interface and its IP address must be known.
Context
An SNMP trap, no matter which interface it comes from, carries a trap address, also called the
address of the trap source interface. When you want to trace a certain event through the trap
address, you can configure the trap source interface.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Trap Service from the service
tree.
Step 4 Click Enable or Disable to change the service status of the trap source interface.
NOTE
If the trap source of the host is in use, you cannot select the trap source interface from the drop-down list
box. The status button that is displayed is Disable. Click Disable to disable the trap source. Then, you can
select the trap source interface from the drop-down list box. The status button that is displayed changes to
Enable.
Step 5 When the trap source is disabled, select the source interface for sending traps from the drop-
down list box, and then click Enable.
----End
Prerequisites
The IP address of the trap receiving host must be known.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Trap Service from the service
tree.
Step 3 Right-click on the Trap Service tab page and choose Create from the shortcut menu.
Step 4 In the Create Receiving Host dialog box, set the related parameters.
NOTE
If the U2000 manages NEs in inband VPN networking mode, the VRF name must be specified.
If more than one receiving host is created, the Create Receiving Host progress bar is displayed. After the
receiving hosts are created, click OK.
----End
Prerequisites
l The selected equipment must support the configuration of the trap service on the U2000.
l Telnet or STelnet parameters must be set on the equipment, and configurations on the
equipment must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Trap Service from the service
tree.
----End
Prerequisites
l The selected equipment must support the configuration of the trap service on the U2000.
l Telnet or STelnet parameters must be set on the equipment, and configurations on the
equipment must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > Trap Service from the service
tree.
Step 4 In the Advanced Configuration dialog box, set the related parameters.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > SSH Service > SSH Global
Configuration from the service tree.
NOTE
If no global SSH data is available, click Synchronize. In the Confirm dialog box, click Yes.
Step 3 Set the parameters on the SSH Global Configuration tab page.
Before the configuration, you can click Synchronize to synchronize the SSH global parameter settings on
the equipment to the U2000 if you need to view them.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > SSH Service > SSH Session
Status from the service tree.
Step 3 Right-click on the SSH Session Status tab page and choose Synchronize from the shortcut
menu.
----End
Prerequisites
l The selected equipment must support the configuration of the SSH service on the U2000.
l SNMP parameters on the U2000 must be consistent with those on the equipment.
Context
When the authentication types of the SSH user include password authentication, you need to
create a local SSH user with exactly the same name in the local user service and set a password
for the user.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > NE Channel Management > SSH Service > SSH User from
the service tree.
Step 4 Set the parameters in the Create SSH User dialog box.
----End
Optional Start
End
The following are the application examples of the ACL rules configured with specified time
ranges:
l A specified website can be accessed only during the working hours (from 8:00 to 18:00)
from Monday to Friday.
l User activities are logged for the users who access a specified website during non-working
hours (from 18:00 to 8:00 on the next day).
Prerequisites
Telnet or STelnet parameters must be set on the U2000 for accessing equipment and equipment
configurations must be synchronized to the U2000.
Context
l When creating a time range, you must configure at least one periodic or absolute time range.
Creating null time ranges is not allowed.
l You can configure multiple periodic or absolute time ranges for a time range.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > Time Range from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Time Range dialog box, set Time Range Name.
Step 5 Right-click in the Absolute Time Range area and choose Create from the shortcut menu.
Step 6 In the Create Absolute Time Range dialog box, set the related parameters and click OK.
Step 7 Right-click in the Periodic Time Range area and choose Create from the shortcut menu.
Step 8 In the Create Periodic Time Range dialog box, set the related parameters and click OK.
----End
Prerequisites
Telnet or STelnet parameters must be set on the U2000 for accessing equipment and equipment
configurations must be synchronized to the U2000.
Context
l You can enable a time range to take effect during the specific period by creating an absolute
time range in the time range.
l You can create an absolute time range when creating a time range. For details, see Creating
a Time Range.
l The absolute time ranges in a time range must be different.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > Time Range from the service tree.
Step 5 On the Detail Information tab page, right-click in the Absolute Time Range area and choose
Create from the shortcut menu.
Step 6 In the Create Absolute Time Range dialog box, set the related parameters and click OK.
----End
Prerequisites
Telnet or STelnet parameters must be set on the U2000 for accessing equipment and equipment
configurations must be synchronized to the U2000.
Context
l You can enable a time range to take effect at a specific time by creating a periodic time
range in the time range.
l You can create a periodic time range when creating a time range. For details, see Creating
a Time Range.
l The periodic time ranges in a time range must be different.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > Time Range from the service tree.
Step 3 On the Time Range tab page, click Query.
Step 4 In the query result area, select a time range record.
Step 5 On the Detail Information tab page, right-click in the Periodic Time Range area and choose
Create from the shortcut menu.
Step 6 In the Create Periodic Time Range dialog box, set the related parameters and click OK.
Step 7 Click Apply.
----End
Prerequisites
Telnet or STelnet parameters must be set on the U2000 for accessing equipment and equipment
configurations must be synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > ACL Group from the service tree.
Step 3 On the ACL Group tab page, click Create.
NOTE
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create ACL Group dialog box, set the related parameters.
----End
An ACL consists of a series of rules. ACL rules have the following features:
l Only source IP addresses can be used as the elements for defining basic ACL rules.
l Advanced ACL rules can be defined by elements including the source IP address and
destination IP address of packets, the protocol type on the IP bearer network, and protocol
features. Advanced ACL rules are more accurate, diversified, and flexible than basic ACL
rules.
l Different from other ACL rules, interface ACL rules are defined according to the interfaces
that receive packets.
l Simple ACL rules can be defined according to information such as the source IP address,
destination IP address, user group, protocol type on the IP bearer network, and protocol
feature. With simple ACL rules, you can define authority group rules for a user to access
the network or communicate with other users.
l Layer 2 ACL rules are applied to the second layer. You can use the Layer 2 ACL rules
when configuring the features including QoS, NAT, policy-based routing, and packet
filtering.
l Ethernet frame ACL rules are defined according to the MAC address and protocol type.
Prerequisites
l Telnet or STelnet parameters must be set on the U2000 for accessing equipment and
equipment configurations must be synchronized to the U2000.
l A basic ACL group must be configured and ACL group configurations on equipment must
be synchronized to the U2000.
l If a time range is configured, the time range must be synchronized.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > ACL Rules > Basic Rule from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Basic Rule dialog box, set the related parameters.
----End
Prerequisites
l Telnet or STelnet parameters must be set on the U2000 for accessing equipment and
equipment configurations must be synchronized to the U2000.
l An interface ACL group must be configured and ACL group configurations on equipment
must be synchronized to the U2000.
l Interface information on equipment must be synchronized to the U2000.
l If a time range is configured, the time range must be synchronized.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > ACL Rules > Interface Rule from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Interface Rule dialog box, set the related parameters.
----End
Prerequisites
l Telnet or STelnet parameters must be set on the U2000 for accessing equipment and
equipment configurations must be synchronized to the U2000.
l An advanced ACL group must be configured and ACL group configurations on equipment
must be synchronized to the U2000.
l If a time range is configured, the time range must be synchronized.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose ACL Management > ACL Rules > Advanced Rule from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Advanced Rule dialog box, set the related parameters.
----End
The advantage of the VLAN is that the broadcast and unicast packets within the VLAN are not
forwarded to other VLANs. Thus, you can control the network traffic, save the investment in
equipment, simplify the network management, and improve the network security.
Creating a VLAN
This topic describes how to create a VLAN on an NE.
Prerequisites
l The equipment must support the configuration of VLANs.
l The configurations of global VLAN management must be synchronized to the NMS.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > VLAN Management > Global VLAN
Management from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create VLAN dialog box, set the related parameters.
----End
Prerequisites
l The equipment must support the configuration of VLANs.
l The configurations of global VLAN management must be synchronized to the NMS.
Context
l One or more member ports can be added to a VLAN.
l Member ports cannot be added to the following VLANs:
– The type of the VLAN is Super.
– The attribute of the VLAN is B-VLAN. In this case, the NE must support the
Attribute entry.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > VLAN Management > Global VLAN
Management from the service tree.
Step 3 On the Global VLAN Management tab page, set the filter criteria and click Query.
Step 6 In the Add Member Port dialog box, set the relate parameters.
l Click the button. The selected member port is added to the Selected Port
list.
l Click the button. All the selected member ports are added to the Selected
Port list.
l Click the button. The selected member port is added to the Selected Port
list.
l Click the button. All the selected member ports are added to the Selected
Port list.
----End
Prerequisites
l The equipment must support the configuration of VLANs.
l The configurations of global VLAN management must be synchronized to the NMS.
Context
l One VLAN corresponds to one VLAN interface.
l The IP addresses of different VLAN interfaces should be in different network segments.
l The VLAN interface cannot be configured on the following VLANs:
– The type of the VLAN is Sub.
– The attribute of the VLAN is B-VLAN. In this case, the NE must support the
Attribute entry.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > VLAN Management > Global VLAN
Management from the service tree.
Step 3 On the Global VLAN Management tab page, set the filter criteria and click Query.
Step 5 On the VLAN Interface tab page, choose whether to configure a VLAN interface.
l If you click the Not Configure VLAN Interface option button, the configured VLAN
interface information is deleted after you click Apply.
l If you click the Configure VLAN Interface option button, set the related parameters.
----End
Prerequisites
The configurations of MAC address forwarding management must be synchronized to the
U2000.
Context
You can bind only a unicast MAC address to an interface. You cannot bind a multicast MAC
address or a special MAC address to an interface. The special MAC address is reserved for other
usages, for example, the MAC address of a special packet.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > MAC Address Forwarding Management > Static
MAC Address Forwarding Table from the service tree.
Step 3 On the Static MAC Address Forwarding Table tab page, click Create.
NOTE
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Static MAC Address Forwarding Entry dialog box, set the related parameters.
----End
Prerequisites
The configurations of MAC address learning restriction rules must be synchronized to the
U2000.
Context
l The supported MAC address learning restriction rules vary according to the equipment
being used.
l Three types of Layer 2 interfaces, that is, FE, GE, and Eth-Trunk interfaces, support MAC
address learning restriction rules. Other physical interfaces, logical interfaces, or sub-
interfaces do not support MAC address learning restriction rules.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > MAC Address Forwarding Management > MAC
Address Learning Restriction from the service tree.
Step 3 On the MAC Address Learning Restriction tab page, select the type of a learning address
restriction rule from the Function drop-down list.
NOTE
The displayed tab varies according to the selected type of the MAC address learning restriction rule.
Step 4 Click Create, or right-click in the query result area and choose Create from the shortcut menu.
Step 5 In the Create MAC Address Learning Restriction dialog box, set the related parameters.
l MAC address learning restriction rule for a VLAN
----End
Context
l The aging time is applicable to only dynamic entries in the MAC address forwarding table
because non-dynamic entries do not age.
l If the aging time is set to 0, no entry of the MAC address forwarding table ages.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > MAC Address Forwarding Management > MAC
Address Aging Time from the service tree.
Step 3 On the MAC Address Aging Time tab page, click Synchronize.
You can check whether the MAC address aging time of the NE meets the requirements.
Step 4 In the MAC Address Aging Time text box, enter the aging time.
NOTE
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management > MAC Address Forwarding Table > MAC
Address Table Information from the service tree.
Step 3 Select the information to be queried from the MAC Address Table Type drop-down list.
Step 5 Click Display. The required information is displayed in the Result area.
NOTE
: saves the information displayed in the Result area to a local disk as a TXT file.
: copies the information selected from the Result area to the clipboard.
: searches for the required information by keyword in the information displayed in the Result area.
----End
Start
No
Is CFM enabled?
Yes
Create an MD
Create an MA
Is the No
interface MIP policy
modified?
Yes
Configure the interface MIP creation
policy
No Do the local
MEP and remote MEP
or MIP exist?
Yes
Start
No
Is EFM enabled?
Yes
Is the status No
of the OAM session
Detected?
Yes
End
Context
OAM functions are unavailable if the following functions are disabled:
l Connectivity Fault Management (CFM)
l Ethernet in the First Mile (EFM)
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM
Management, and then click Ethernet OAM Global Configuration.
NOTE
If data synchronization is not performed for the NE, perform data synchronization first.
----End
Creating an MD
This topic describes how to create a Maintenance Domain (MD). An MD is a network or a part
of a network is a network or a part of a network for which Connectivity Fault Management
(CFM) is performed. Different MDs can be set to restrict the areas that packets in different
Operation, Administration, and Maintenance (OAM) areas can arrive or transverse.
Prerequisites
CFM must be enabled on the Ethernet OAM Global Configuration tab page.
Context
A maximum of 16 MDs can be configured for an NE.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM, and then click MD Management.
Step 3 On the MD Management tab page, Click Create, or right-click in the query result area and
select Create on the shortcut menu.
Step 4 In the Create MD dialog box, set MD parameters.
l Some parameters may fail to be copied to the destination NE because of NE version differences.
l The MD information copied from another NE can be modified as needed.
l Method 2:
Select the Create Default MD check box and set the related parameters.
NOTE
This check box is available only when CFM Version is set to Standard on the Ethernet OAM
Global Configuration tab page.
l Method 3:
Set MD Name and other parameters.
----End
Creating an MA
This topic describes how to create a Maintenance Association (MA). An MA is a part of a
Maintenance Domain (MD). An MD can be divided into one or more MAs. Ethernet
Connectivity Fault Management (CFM) performs connectivity fault detection for each MA.
Prerequisites
l CFM must be enabled on the Ethernet OAM Global Configuration tab page.
l An MD must exist.
Context
A maximum of 512 MAs can be configured for an NE.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM, and then click MA Management.
Step 3 On the MA Management tab page, Click Create, or right-click in the query result area and
select Create on the shortcut menu.
To copy the MA information created for another NE, perform the following operations:
Click Select and select the MA information created for another NE.
NOTE
l Some parameters may fail to be copied to the destination NE because of NE version differences.
l The MA information copied from another NE can be modified as needed.
Step 5 Optional: On the Parameter of Alarm tab page, set Operation, Administration, and
Maintenance (OAM) alarm parameters.
Step 6 Optional: On the Parameter of Alarm tab page, set Alarm indicate function.
----End
Prerequisites
l Connectivity Fault Management (CFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
l An MA must exist.
Context
l A local MEP can be created on a Gigabit Ethernet (GE) interface, a common Fast Ethernet
(FE) interface, or a trunk interface.
l A maximum of 512 local MEPs can be configured for an NE.
l If an MA is not associated with any service, the local MEP direction in the MA cannot be
set to Inward.
l The level of a Maintenance Association Intermediate Point (MIP) on an interface cannot
be lower than the level of any MEP on the interface. The creation of a MEP affects the MIP
level.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM, and then click Local MEP Management.
Step 3 On the Local MEP Management tab page, Click Create, or right-click in the query result area
and select Create on the shortcut menu.
Step 4 In the Create Local MEP dialog box, set the general parameters.
To copy the local MEP information created for another NE, perform the following operations:
1. Click the ... button on the right of the MD Name text box. Then, select an MD and an MA.
2. Click Select and select the MEP information created for another NE.
The MEP information copied from another NE can be modified as needed.
NOTE
Some parameters may fail to be copied to the destination NE because of NE version differences.
Step 5 Optional: On the AIS VLAN Configuration tab page, set alarm indication signal parameters.
Prerequisites
l Connectivity Fault Management (CFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
l A Maintenance Domain (MD) must exist.
l An MA must exist.
Context
l A maximum of 512 remote MEPs can be configured for an NE.
l A maximum of 512 remote MEPs can be configured for an MA.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM, and then click Remote MEP Management.
Step 3 On the Remote MEP Management tab page, Click Create, or right-click in the query result
area and select Create on the shortcut menu.
Step 4 In the Create Remote MEP dialog box, set the related parameters.
To copy the local MEP information created for another NE, perform the following operations:
1. Click the ... button on the right of the MD Name text box. Then, select an MD and an MA.
2. Click Select and select the local MEP information created for another NE.
The local MEP information copied from another NE can be modified as needed.
NOTE
Some parameters may fail to be copied to the destination NE because of NE version differences.
----End
Prerequisites
l Connectivity Fault Management (CFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
l A Maintenance Domain (MD) must exist.
l A Maintenance Association (MA) must exist.
l A local Maintenance Association End Point (MEP) must exist.
Context
If the MIP creation policy is set to Default or Explicit on the U2000, the NE automatically
creates MIPs based on the policy.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM, and then click MIP Policy Management.
Step 3 On the MIP Policy Management tab page, click Query. The NE automatically generates MIP
information based on certain rules and displays the information in the query result area.
Step 4 Select the MIP information to be modified and click the Configure Creation Policy drop-down
button. Alternatively, right-click the information and choose Configure Creation Policy from
the shortcut menu. Use any of the preceding methods to modify the MIP creation policy for the
interface.
----End
Creating a MIP
This topic describes how to create a Maintenance Association Intermediate Point (MIP) on an
NE. A MIP is a node inside an MA. MEPs periodically send multicast CCMs. A MIP needs to
be used to locate faults.
Prerequisites
1. Connectivity Fault Management (CFM) must be enabled globally.
2. A MIP policy must be configured.
3. 802.1ag information must be synchronized to the U2000.
Context
When all devices in the MD are enabled with the CCM sending function, MEPs send multicast
CCMs periodically. If a MEP does not receive any CCMs from an RMEP within three
consecutive sending intervals, this means that a connectivity fault between the MEP and RMEP
occurs. A MIP needs to be used to locate the fault.
LTM
MEP1 MEP2
MIP1 MIP2
LTR
MEP
MIP
LTM data flow
LTR data flow
As shown in Figure 3-4, the 802.1ag MAC trace operation is performed from MEP1 to MEP2.
MEP1 sends a Linktrace message (LTM) to MEP2. After receiving the LTM, MIP1 replies
MEP1 with an LTR packet and forwards the LTM. Because a fault occurs on the link between
MIP1 and MIP2, MIP2 fails to receive the LTM and does not send the LTR packet. This means
that the MEP2 is faulty. In this way, the faulty device is located.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > OAM Management > Ethernet OAM Management > Ethernet Service
OAM > MIP Information from service tree.
Step 3 On the MIP Information tab page, click Create. Alternatively, right-click in the query result
area and choose Create from the shortcut menu.
Step 4 In the Create MIP Information dialog box, set the related parameters.
----End
Prerequisites
l Connectivity Fault Management (CFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
l A Maintenance Domain (MD) must exist.
l A Maintenance Association (MA) must exist.
l Bidirectional Forwarding Detection (BFD) must be configured and a BFD session must
exist.
Context
CFM-BFD binding is applicable to the following scenario:
As shown in Figure 3-5, CEs are dual homed to PEs that belong to a Multiprotocol Label
Switching (MPLS) network. BFD is configured for the MPLS Label Switched Path (LSP)
between PEs, and Ethernet Operation, Administration, and Maintenance (OAM) is configured
between the CEs and PEs. The configuration helps to implement end-to-end link fault detection.
If the BFD module on the core network detects a fault, the related PE notifies the Ethernet OAM
module of the fault. Then, the related CE is switched to the backup path.
PE1 PE2
PE3 PE4
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Service OAM > CFM-BFD Binding.
Step 4 In the Create CFM-BFD Binding dialog box, set the related parameters.
1. Click the ... button on the right of the MD Name text box. In the dialog box that is displayed,
select the MD and MA to be bound.
2. Click the ... button on the right of the BFD Session ID text box. In the dialog box that is
displayed, select the BFD session to be bound.
3. Select a value from the Direction drop-down list.
The transmission direction refers to the notifier and the notified party involved in detection
after the binding is configured. For example, if CFM-BFD is selected, when the OAM
module detects a fault, it sends the fault information to the BFD module while switching
the local protection link. The BFD module then switches to the downlink (or uplink)
protection link to finally implement the switching of the entire protection link.
4. Click OK or Apply.
----End
Prerequisites
1. CFM must be enabled.
2. At least two Maintenance Domains (MDs) must exist.
3. At least two MAs must exist.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > OAM Management > Ethernet OAM Management > Ethernet Service
OAM > CFM-CFM Binding from the service tree.
Step 3 On the CFM-CFM Binding tab page, click Create.
Step 4 In the Create CFM-CFM Binding dialog box, set binding parameters.
1. Click the ... button on the right of the Ingress MD Name text box. In the dialog box that
is displayed, select the uplink MD and MA to be bound.
2. Click the ... button on the right of the Egress MD Name text box. In the dialog box that is
displayed, select the downlink MD and MA to be bound.
3. Select a value from the Direction drop-down list.
4. Click OK or Apply.
----End
Prerequisites
EFM is enabled in Ethernet OAM Global Configuration.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Link OAM > Ethernet Link OAM.
Step 3 On the Ethernet Link OAM tab, click Query. Information about the available ports on the
device is displayed.
Step 4 Select the port, and then click Set, or right-click it and select Set on the shortcut menu.
Step 5 In the Configure Port dialog box, click the General and Advanced tabs to set the related
parameters.
NOTE
The U2000 provides default values for parameters on the Advanced tab. It is recommended to adopt the
default values rather than modify those parameters.
----End
Prerequisites
Ethernet in the First Mile (EFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Link OAM > Ethernet Link OAM.
Step 3 On the Ethernet Link OAM tab page, click Query. Information about the available ports on
the NE is displayed.
Step 4 Select a port and click the OAM Session tab. Then, click Synchronize.
Step 5 After the synchronization, view the OAM session status in the EFM Protocol Enabling
Status column.
----End
Prerequisites
Two ports must be connected directly by a link and the following requirements must be met to
ensure the link connectivity:
l Ethernet in the First Mile (EFM) must be enabled on the Ethernet OAM Global
Configuration tab page.
l EFM must be enabled on both ports.
l The status of the Operation, Administration, and Maintenance (OAM) session is
Detection on at least one port.
Context
Performing a loopback test on a port interrupts all services running on the port.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> Ethernet Link OAM > Ethernet Link OAM.
Step 3 On the Ethernet Link OAM tab page, click Query. Information about the available interfaces
is displayed in the query result area.
Step 4 Select a port and click Loopback Test. Alternatively, right-click the port and choose Loopback
Test from the shortcut menu.
----End
Prerequisites
1. Connectivity Fault Management (CFM) must be enabled.
2. A Maintenance Domain (MD) must exist.
3. A Maintenance Association (MA) must exist.
4. BFD must be configured and a BFD session must exist.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > OAM Management > Ethernet OAM Management > Ethernet Link
OAM > EFM-BFD Binding from the service tree.
Step 3 On the EFM-BFD Binding tab page, click Create.
Step 4 In the Create EFM-BFD Binding dialog box, set binding parameters.
1. Click the ... button on the right of the Interface Name text box. In the dialog box that is
displayed, select the EFM interface to be bound.
2. Click the ... button on the right of the BFD Session ID text box. In the dialog box that is
displayed, select the BFD session to be bound.
3. Select a value from the Bind Direction drop-down list.
4. Click OK or Apply.
----End
Prerequisites
1. CFM must be enabled.
2. An MD must exist.
3. An MA must exist.
Context
EFM-CFM binding is applicable to the following scenario:
IEEE 802.3ah is designed for the last mile of the Ethernet to detect the direct link between a CE
and a PE. IEEE 802.1ag is designed for a group of services or some specific network devices to
detect faults on the network. It functions between the following devices:
l CE and CE
l PE and PE
l CE and PE
As shown in Figure 3-6, EFM OAM or Ethernet CFM runs between CE1 and PE1, and between
CE2 and PE2; Ethernet CFM runs between PE1 and PE2. Configure the association between
Ethernet OAMs. When a fault occurs on the link between CE1 and PE1, Ethernet CFM sends
alarms of the fault to CE2.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > OAM Management > Ethernet OAM Management > Ethernet Link
OAM > EFM-CFM Binding from the service tree.
Step 4 In the Create EFM-CFM Binding dialog box, set binding parameters.
1. Click the ... button on the right of the Interface Name text box. In the dialog box that is
displayed, select the EFM interface to be bound.
2. Click the ... button on the right of the MD Name text box. In the dialog box that is displayed,
select the MD and MA to be bound.
3. Select a value from the Bind Direction drop-down list.
4. Click OK or Apply.
----End
Test diagnosis is classified into two types: Loopback (LB) and Link Trace (LT). LB is used to
detect the connectivity of a link between two NEs; LT is used to locate the connectivity fault on
a link between two NEs. According to the types of tested links, test diagnosis tasks are classified
as follows:
l 802.1ag-based test diagnosis task
Run an 802.1ag-based test diagnosis task for the network where the Maintenance Domain
(MD), Maintenance Association (MA), and Maintenance Association End Points (MEPs)
are configured to locate the connectivity fault between MEPs at the same level or between
a MEP and a Maintenance Association Intermediate Point (MIP) at the same level.
l Multicast test diagnosis task
Run a multicast test diagnosis task to discover all remote MEPs before configuring a remote
RMEP.
Prerequisites
l The current Maintenance Association (MA) must be associated with a Service.
l A local Maintenance Association End Point (MEP) must be configured for the current MA.
If an outgoing interface needs to be specified, the interface must meet the following
requirements:
– No inward MEP has been configured for it.
– It has been added to the VLAN that is associated with the current MA.
l The destination node can be either a remote MEP or a Maintenance Association
Intermediate Point (MIP). If the destination node is a remote MEP, specify this remote
MEP for the local MEP.
l No MD, MA, or MEP has been configured for the intermediate NEs on the link to be tested.
Context
A maximum of 4096 802.1ag-based test diagnosis tasks can be created for an NE.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM
Management, and then click Test Diagnosis.
Step 3 On the Test Diagnosis tab page, click the Task Type drop-down button and select Test
Diagnosis Task.
Step 4 Click Create, or right-click in the query result area and select Create on the shortcut menu.
Step 5 Set test diagnosis parameters in the Create Test Diagnosis Task dialog box.
Step 6 Optional: Click Set on the right of Diagnosis Parameter to set test diagnosis parameters.
Alternatively, use the default parameter values.
NOTE
The U2000 provides default values for test diagnosis parameters. Using the default values is recommended.
The U2000 creates a test diagnosis task and runs the task based on the set parameters.
In the Running Result area, view the result of diagnosis. After the operation is complete, click
Close to close the dialog box.
----End
Prerequisites
A Maintenance Domain (MD), Maintenance Association (MA), and local MEP must exist.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM
Management, and then click Test Diagnosis.
Step 3 On the Test Diagnosis tab page, click the Task Type drop-down button and select Multicast
Test Diagnosis Task.
Step 4 Click Create, or right-click in the query result area and select Create on the shortcut menu.
Step 5 Set test diagnosis parameters in the Multicast General Test Diagnosis Task dialog box.
Step 6 Optional: Click Set on the right of Diagnosis Parameter to set test diagnosis parameters.
Alternatively, use the default parameter values.
Step 8 If the Immediate Run check box is selected, the Confirm dialog box is displayed. Click OK.
The U2000 creates a test diagnosis task and runs the task based on the set parameters.
In the Running Result area, view the result of diagnosis. After the operation is complete, click
Close to close the dialog box.
----End
Prerequisites
l MDs, MAs, and RMEPs must be created.
l The MA binding type must be Map VSI, Map L2VC or Map VLAN.
Context
It is applicable to only 802.1ag-based OAM statistics.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand Reliablity > OAM Management > Ethernet OAM Management
> OAM Measure.
Step 3 Click Create, or right-click in the query result area and select Create on the shortcut menu.
Step 5 Optional: If Measure Type is set to Packet loss ratio, set Single Ended Configuration and
Dual Ended Configuration related parameters.
Step 6 Optional: If Measure Type is set to Delay, set One Way Configuration and Two Way
Configuration related parameters.
----End
Follow-up Procedure
Run OAM measure.
1. Select a measure job in the query result area, click Run or right-click in the query result
area and select Run on the shortcut menu.
2. Click OK in the Confirm dialog box to run OAM measure.
3. In the Running Result area, view the OAM measurement result.
4. Click Close.
Prerequisites
Telnet or STelnet parameters must have been set on the device, and configurations on the device
must have been synchronized to the U2000.
Context
NOTE
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliability > OAM Management > MPLS-TP OAM Management > MEG
Management from the service tree.
Step 3 On the MEG Management tab page, click Create, or right-click in the query result area and
choose Create from the shortcut menu.
Step 4 In the Create MEG Management dialog box, set MEG Name.
Step 6 On the MEG Management tab page, select the created MEG.
Step 7 In the details area, click the ME Configuration tab and click Create.
Step 10 On the MEG Management tab page, select the created ME.
Step 11 On the MEG Management tab page, click Configure, or right-click in the query result area
and choose Configure from the shortcut menu.
Step 12 In the Configure MEG Management dialog box, set the related parameters.
----End
Follow-up Procedure
View the delay and packet loss ratio related to the created MEG.
On the MEG Management tab page, select the MEG for which complete information has been
configured and perform one of the following steps:
l Right-click and choose One Way Delay from the shortcut menu to set the related
parameters and view the one-way delay.
l Right-click and choose Single Ended Lost from the shortcut menu to set the related
parameters and view the single-end packet loss ratio.
l Right-click and choose Two Way Delay from the shortcut menu to set the related
parameters and view the two-way delay.
l Right-click and choose Dual Ended Lost from the shortcut menu to set the related
parameters and view the dual-end packet loss ratio.
l Right-click and choose LB Test from the shortcut menu to perform a loopback test.
Figure 3-7 Flowchart of configuring the PTP function for the OC/TC/BC equipment
Start
End
For details about the configuration tasks shown in Figure 3-7, see Table 3-1.
Operation Remarks
1. Configuring global PTP Configures the global PTP attributes on the General tab page,
information which includes enabling PTP, and setting Clock Domain,
Clock Type, and BITS Clock Source Global Information.
2. Configuring port clock Configures the Port Clock Source attribute on the Clock
source Source tab page, which includes enabling PTP on interfaces,
and setting the packet encapsulation mode and packet
receiving and sending intervals.
Start
End
For details about the configuration tasks shown in Figure 3-8, see Table 3-2.
Operation Remarks
1. Configuring global PTP Configures the global PTP attributes on the General tab
information page, which includes enabling PTP, and setting Clock
Domain, Clock Type, and BITS Clock Source Global
Information.
2. Configuring local clock source Configures the BITS Clock Source attribute on the
Clock Source tab page, which includes enabling the
configuration function and setting BMC parameters.
Start
End
For details about the configuration tasks shown in Figure 3-9, see Table 3-3.
Operation Remarks
1. Configuring global PTP Configures the global PTP attributes on the General tab
information page, which includes enabling PTP, and setting Clock
Domain, Clock Type, and BITS Clock Source Global
Information.
2. Configuring BITS clock source Configures the BITS Clock Source attribute on the
Clock Source tab page, which includes enabling the
configuration function and setting BMC parameters.
Start
End
For details about the configuration tasks shown in Figure 3-10, see Table 3-4.
Operation Remarks
1. Configuring global physical Configures the global attributes of the physical clock,
clock information which includes enabling Ethernet clock synchronization,
setting System Clock Running Mode and Advance, and
selecting the clock source.
2. Configuring clock source Configures the clock source attribute, which includes
setting Port Clock Source or Other Clock Source.
NOTE
l Port Clock Source: indicates clock sources configured on
router ports. To configure a port clock source, you need to
manually select a port and set the necessary parameters, such
as enabling the clock function and setting the SSM level.
l Other Clock Source: indicates other clock sources of routers,
such as the BITS clock source, PTP clock source. Such clock
sources cannot be created on the NMS. Only the related
attributes can be queried or modified.
NOTE
The Apply button is applicable to all the tabs in the PTP clock management window. After the parameters
on all the tab pages of PTP clock management are set, you can click Apply to deploy all PTP parameters
simultaneously.
Prerequisites
l Configure the IP address of the NE interface.
l Configure the static route or IGP to make the routes between NEs reachable.
l Synchronize the data of the PTP module on the NMS side.
Context
l The PTP clock signal can be normally transmitted on the entire clock synchronization
network only after all NEs on the clock synchronization network are configured with PTP
globally.
l All the NEs that are configured with clock synchronization through PTP packets must be
on the same PTP clock domain.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > PTP Clock Management from the service tree.
Step 4 Select the Enable PTP check box. Then, configure the general information about the PTP clock.
----End
Prerequisites
l Configure the interface IP address of the NE.
l Configure the static route or IGP protocol to make the IP route between NEs reachable.
l Enable the PTP functions on NEs.
l Synchronize the data of the PTP module on the NMS side.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > PTP Clock Management from the service tree.
Step 3 Click Clock Source tab.
Step 4 Click Local Clock Source tab.
Step 5 Set Clock Source ID and BMC Parameter.
----End
Result
After the local clock source is successfully configured, you can view the configurations of the
PTP function and the BMC running status of equipment on the Local Clock Source tab.
Prerequisites
You must complete the following tasks before setting the BITS clock source attributes:
l Set the interface IP address.
l Configure the static route or IGP protocol to make the IP route between nodes reachable.
l Enable the PTP function.
l Synchronize the data of the PTP module on the NMS side.
Context
You can apply the following roadmap to configure the BITS clock as the PTP clock source:
l Select the BITS clock source traced by the device.
l Set the attributes of the BITS clock.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > PTP Clock Management from the service tree.
Step 5 Select the BITS clock to be connected to the device in the BITS clock source list.
Step 6 On the General tab page in the lower part, set Signal Type and Direction.
l If Signal Type is set to 2Mbits/s or 2Mhz, Direction cannot be set.
l If Signal Type is set to 1pps, Direction can be set to in or out.
Step 8 In the BMC Parameter area, set the attributes of the BITS signal.
----End
Prerequisites
l The selected interface must support the PTP function.
l Synchronize the data of the PTP module on the NMS side.
Context
You can apply the following roadmap to configure the PTP attributes on an interface:
l Select an interface.
l Set the PTP attributes on the interface.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > PTP Clock Management from the service tree.
Step 5 Click Add. In the dialog box that is displayed, select an interface and then click OK.
Step 6 On the Basic Information tab page in the lower part, set the PTP attributes of the interface.
Step 7 Optional: Set Packet Encapsulation Mode, Interval for Receiving and Sending Packets,
Asymmetry Delay Correction, and TCOC Static Clock Source as required.
NOTE
The TCOC static clock source can be configured only when the clock type is P2PTCOC or E2ETCOC.
----End
Prerequisites
l Configure the IP address of the NE interface.
l Configure the static route or IGP to make the routes between NEs reachable.
l Synchronize the data of the PTP module on the NMS side.
l On the PTP Clock Management tab page, select the Enable PTP Adaptive check box
on the General tab page to configure the adaptive clock.
l After the Enable PTP Adaptive check box is selected, you cannot set parameters on the
General and Clock Source tab pages.
Context
l All the NEs that are configured with clock synchronization by means of PTP packets must
be on the same PTP clock domain.
l On the PTP Clock Management tab page, after the Enable PTP Adaptive check box on
the General tab page is selected and configurations are deployed, the NEs are globally
enabled with PTP automatically.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > PTP Clock Management from the service tree.
Step 6 In the Basic Information area, configure basic information about the adaptive clock.
----End
NOTE
The Apply button is applicable to all the tabs in the physical clock management window. After the
parameters on all the tab pages of physical clock management are set, you can click Apply to deploy all
parameters simultaneously.
Prerequisites
l The equipment must support the physical clock.
l The configurations of the physical clock must be synchronized to the NMS.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > Physical Clock Management from the service tree.
Step 5 Set System Clock Running Mode, System Trace Source Status, and Advance.
Step 6 Optional: Select a clock source record and click Configure. Then, you can configure the clock
source selection mode.
----End
Prerequisites
l The equipment must support the physical clock.
l The configurations of the physical clock must be synchronized to the NMS.
Context
The clock source of a physical clock can be a port clock source or other clock source.
l Port clock sources are clock source configured on devices. To configure a port clock source,
you need to manually select the desired port and set the mandatory parameters, such as
enabling the clock function and setting the SSM level.
l Other clock sources are other clock sources of devices, such as the BITS clock source, PTP
clock source. Such clock sources cannot be created on the NMS. Only the related attributes
can be queried or modified.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > Physical Clock Management from the service tree.
Step 4 Optional: (If the required port already exists, you do not need to perform this step.) On the Port
Clock Source tab page, click Add. In the dialog box that is displayed, select the required port.
Step 5 Select the required port and set port clock source-related parameters.
Step 6 On the Other Clock Source tab page, click Query to query the attributes of other clock sources.
Step 7 Optional: Select a clock source record. On the General tab page, you can modify the attributes
of the clock source.
----End
Prerequisites
The clock management data must be synchronized to the U2000.
Context
l In the clock view, the local clock source, external clock source, and clock link can be
displayed according certain filter criteria. Different status icons are used for different types
of local clock source or external clock source use.
l Clock link indicates the clock tracking relationship between clock NEs. The clock link
between NE A and NE B refers to the clock signal that NE B tracks from NE A.
l When the clock tracking relationship changes, the NMS automatically updates the tracking
relationship in the clock view.
Procedure
Step 1 On Workbench, double-click Main Topology.
Step 2 Select Clock View from the Current View drop-down list.
Step 3 Select the NE to be queried or configured from the Object Tree. In the blank area of the clock
view, right-click and choose Search Clock Link from the shortcut menu.
Step 4 In the dialog box that is displayed, select NEs for search and click OK. The clock tracking
relationship of each NE is displayed.
----End
Prerequisites
The data of the clock management module must be synchronized to the U2000.
Context
When the clock source switches on the equipment, the U2000 receives the trap messages reported
by NEs and the trap messages are displayed as events on the U2000 alarm panel. In addition,
the clock topology status displayed on the U2000 changes accordingly.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Clock Management > > View Clock Source Switching Records from the service
tree.
Step 3 Click Condition. In the Set Filter Condition dialog box, set query conditions, and then click
OK.
NOTE
When querying all records, you can click Query without setting any filtering rule.
----End
Navigation Path
Choose Clock Management > PTP Clock Management from the service tree.Click General
tab.
Button Description
Button Description
Button Description
Parameter Description
Clock Definition: -
Synchronize Indicates the synchronization
Status status of a clock.
Table 3-6 Description of the parameters on the View-Current Master Clock tab page
Parameter Description
Steps Definition:
Indicates the number of hops between the current
equipment and the current GrandMaster equipment.
Parameter Description
Priority 1 Definition:
Indicates that priority of the clock source. The smaller
priority value indicates the higher priority of the clock
source.
Priority 2 Definition:
Indicates that priority of the clock source. The smaller
priority value indicates the higher priority of the clock
source.
Navigation Path
Choose Clock Management > PTP Clock Management from the service tree.Click Clock
Source tab.
Quick Navigation
Tab Page Area on the Tab Page
Button Description
Button Description
Parameter Description
Table 3-7 Description of the parameters on the BITS Clock Source tab page
Parameter Description
Status Definition:
Indicates the available status of the BITS clock source.
Table 3-8 Description of the parameters on the BITS Clock Source-General tab page
Table 3-9 Description of the parameters on the Port Clock Source tab page
Parameter Description
Port ID Definition:
Indicates the port number of the currently accessed clock source.
Table 3-10 Description of the parameters on the Port Clock Source-Basic Information tab page
Table 3-11 Description of the parameters on the Port Clock Source-Packet Encapsulation
Mode tab page
Table 3-12 Description of the parameters on the Port Clock Source-Interval for Receiving and
Sending Packets tab page
Table 3-13 Description of the parameters on the Port Clock Source-Asymmetric Delay
Correction tab page
Table 3-14 Port Clock Source-TCOC Static Clock Source tab page
Table 3-15 Description of the parameters on the Port Clock Source-Local Clock Source tab page
Navigation Path
Choose Clock Management > PTP Clock Management from the service tree.On the PTP
Clock Management tab page, select the Enable PTP Adaptative check box on the General
tab page, and click the Adaptive Clock tab.
Button Description
Button Description
Parameter Description
Basic Information
Navigation Path
Choose Clock Management > Physical Clock Management from the service tree.Click
General tab.
Button Description
Button Description
Parameter Description
Navigation Path
Choose Clock Management > Physical Clock Management from the service tree.Click Clock
Source tab.
Quick Navigation
Tab Page Area on the Tab Page
Button Description
Button Description
Parameter Description
Table 3-18 Description of the parameters on the Port Clock Source tab page
Parameter Description
Table 3-19 Description of the parameters on the Port Clock-General tab page
Table 3-20 Description of parameters on the Other Clock Source tab page
Parameter Description
Table 3-21 Description of the parameters on the Other Clock Source-General tab page
Navigation Path
Choose Clock Management > > View Clock Source Switching Records from the service
tree.
Button Description
Button Description
Condition Sets the filtering condition so that only the information meeting the
condition can be queried.
Save As Saves the query results as files in xls, txt, html, or csv format to a local
disk.
Parameter Description
Parameter Description
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > Global Routing Configuration from the service tree.
Step 3 On the Global Routing Configuration tab page,click View to display the related view windows.
The required global route parameters information is displayed in the related view windows.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > Routing Information from the service tree.
Step 3 Select the routing information to be queried from the View Routing Information drop-down
list.
NOTE
If viewing the private routing information at the PE end, it need that choose VPN in the Condition area
and input the VPN name.
Step 5 Click Display. The required routing information is displayed in the Result area.
NOTE
: saves the routing information displayed in the Result area to a local disk as a TXT file.
: copies the routing information selected from the Result area to the clipboard.
: searches for the required information by keyword in the routing information displayed in the Result
area.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Context
A static route with both the destination IP address and subnet mask as 0.0.0.0 is a default one.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > Static Route from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Instance from the service tree.
Step 3 Click Create, the Create BGP Instance dialog box is displayed.
Step 4 On the General, Router Property, and Address Family tab page, set the related parameters.
----End
Prerequisites
l The selected NE must support BGP configuration.
l Route management data must have been synchronized to the U2000.
l Before configuring basic BGP functions, check that the network-layer IP addresses of
adjacent nodes are reachable.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Instance from the service tree.
Step 3 Click Configure, the Configure BGP Instance dialog box is displayed.
Step 4 On the Address Family page tab, click Create, the Create Address Family dialog box is
displayed.
Step 6 On the Address Family page tab, click Configure, the Configure BGP Address Family dialog
box is displayed.
Step 7 On the Router, Control Route Information and Advanced page tab, set the related parameters.
NOTE
Route import and route distribution can be configured on the Control Route Information page tab. Load
balance can be configured on the Advanced page tab.
----End
Prerequisites
l Route management data must have been synchronized to the U2000.
Context
l A peer group AS number must be specified only when you create an External BGP (EBGP)
peer group.
l A peer group name uniquely identifies a peer group. It is mandatory.
l Peer groups are classified into three types: internal BGP (IBGP) peer group, pure EBGP
peer group, and hybrid EBGP peer group.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Peer Group from the
service tree.
2. Click the Routing Policy tab and set the related parameters on this tab page.
3. Click the Password Verification tab. Then, set Password Type and enter values in the
New Password and Confirm Password text boxes.
4. Click the Member tab. Then, click Select. In the Select Peer list box, select the peers to
be added.
5. Click OK.
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
l Route management data must have been synchronized to the U2000.
l Before creating a BGP peer, check that the network-layer IP addresses of adjacent nodes
are reachable.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Peer from the service
tree.
2. Click the Routing Policy tab and set the related parameters on this tab page.
3. Click the Password Verification tab. Then, set Password Type and enter values in the
New Password and Confirm Password text boxes.
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
l BGP and an Interior Gateway Protocol (IGP) must have been configured for the selected
NE and be running properly.
l Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Import Route from
the service tree.
Step 3 Click Create. In the dialog box that is displayed, set Protocol, Process ID, MED Value, and
Routing Policy.
----End
Advertising a Route
This topic describes how to advertise a route, that is, how to statically add a route in the local
routing table to the Border Gateway Protocol (BGP) routing table and advertise it to a peer.
Prerequisites
l BGP must have been configured for the selected NE and be running properly.
l The route to be advertised must exist in the local IP routing table.
l Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Route Distribution
from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set IP Address, Mask, and Routing Policy.
----End
Prerequisites
l The Border Gateway Protocol (BGP) and VPN instances must have been configured for
the selected NE and be running properly.
l Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > VPN Instance Address Family from the service tree.
Step 3 Click Create, the Create VPN Instance Address Family dialog box is displayed.
Step 4 On the General, Router Property, Peer(Group), Control Route Information, and
Advanced tab page, set the related parameters.
NOTE
Route import and route distribution can be configured on the Control Route Information page tab. Load
balance can be configured on the Advanced page tab.
----End
Prerequisites
l The Border Gateway Protocol (BGP) and VPN instances must have been configured for
the selected NE and be running properly.
l Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > VPN Ipv4 Address Family from the service tree.
Step 3 Click Create, the Create VPN Ipv4 Address Family dialog box is displayed.
Step 4 On the General and Peer(Group) tab page, set the related parameters.
----End
Prerequisites
l Route management data must have been synchronized to the U2000.
l Bidirectional Forwarding Detection (BFD) must be enabled globally. If BFD is not enabled
globally and only BFD parameters are set during OSPF process creation, creating BFD
sessions fails. For details about how to enable BFD globally, see BFD Management-
Configuring Global BFD Attributes.
Context
BFD configured for an OSPF interface has a higher priority than BFD configured for a process.
If interface BFD configurations are different from process BFD configurations, BFD sessions
are created based on parameter settings on the interface.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > OSPF Route > OSPF Process from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
1. On the General tab page, set general parameters for creating an OSPF process.
2. On the Area tab page, click Create. In the dialog box that is displayed, set the related area
parameters.
3. On the Import Route tab page, click Create and Advanced. In the dialog boxes that are
displayed, set parameters for the route to be imported.
4. On the Advanced tab page, set parameters such as route filtering, route optimization, and
route aggregation.
5. On the BFD Detection tab page, set BFD-related parameters.
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
l Route management data must have been synchronized to the U2000.
l Bidirectional Forwarding Detection (BFD) must be enabled globally. If BFD is not enabled
globally and only BFD parameters are set during OSPF process creation, creating BFD
sessions fails. For details about how to enable BFD globally, see BFD Management-
Configuring Global BFD Attributes.
Context
BFD configured for an OSPF interface has a higher priority than BFD configured for a process.
If interface BFD configurations are different from process BFD configurations, BFD sessions
are created based on parameter settings on the interface.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > OSPF Route > OSPF Interface from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
1. On the General tab page, set general parameters for creating an OSPF interface.
NOTE
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > IS-IS Route > IS-IS Process from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
1. On the General tab page, set general parameters for creating an IS-IS process.
2. Optional: On the Import Route tab page, set route import parameters.
NOTE
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > IS-IS Route > IS-IS Interface from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
NOTE
In the query result area, Deployment Status indicates whether configurations on the U2000 have been
deployed to NEs. If these configurations have been deployed to NEs, the value of Deployment Status is
Deployed; if these configurations have not been deployed to NEs, the value of Deployment Status is
Undeployed.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > IP Prefix from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
1. Set IP Prefix Name.
2. In the IP Prefix Filter Rules area, click Create and set filter rule-related parameters.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > Policy Management from the service tree.
Step 3 Click Create. In the dialog box that is displayed, set the related parameters.
1. Set Policy Type and Policy Name.
2. In the Node Information area, click Create and set the matching mode to permit or deny.
----End
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Peer or Route
Management > BGP Route > Private Network Route > VPN Instance Address Family from
the service tree.
Step 3 Choose Route Management > BGP Route > BGP Instance or Route Management > BGP
Route > Address Family any address family node from the service tree.
Step 4 Click Query. All the peer records or VPN instance records are displayed in the query result area.
Step 5 Click Query. Choose one record in the query result area.
Step 6 Right-click a record and choose View Running Information > BGP Peer Group
Information from the shortcut menu.
Step 7 In the Peer Group area on the Peer(Group) tab page, select a peer record, right-click, and
choose View Running Information > BGP Peer Group Information from the shortcut menu.
Step 8 In the BGP Peer Group Information dialog box, set VPN and click Display.
Information about the BGP peer group is displayed in the query result area.
----End
Follow-up Procedure
The displayed running information about the BGP peer group can be saved, copied, or searched
as follows:
: saves the information displayed in the query result area to a local disk as a TXT file.
: copies the information selected from the query result area to the clipboard.
: searches for the required information by keyword in the running information displayed in
the query result area.
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > BGP Route > Public Network Route > Peer or Route
Management > BGP Route > Private Network Route > VPN Instance Address Family from
the service tree.
NOTE
On the VPN Instance Address Family tab page, running information about only BGP peers is displayed.
The reason is that each record in the Virtual Private Network (VPN) instance address family represents a
VPN instance, but the BGP peer log information and BGP peer statistics are based on a single peer.
Step 3 Choose Route Management > BGP Route > BGP Instance or Route Management > BGP
Route > Address Family any address family node from the service tree.
NOTE
On the VPN Instance Address Family tab page, running information about only BGP peers is displayed.
The reason is that each record in the Virtual Private Network (VPN) instance address family represents a
VPN instance, but the BGP peer log information and BGP peer statistics are based on a single peer.
Step 4 Click Query. All the peer records or VPN instance records are displayed in the query result area.
Step 5 Click Query. Choose one record in the query result area.
Step 6 To view information about a BGP peer, right-click a record in the query result area and choose
View Running Information > BGP Peer Information from the shortcut menu.
Step 7 In the Peer area on the Peer(Group) tab page, select a peer record, right-click, and choose View
Running Information > BGP Peer Information, View Running Information > BGP Peer
Log Information, or View Running Information > BGP Peer Statistic Information from the
shortcut menu.
Step 8 In the BGP Peer Information dialog box, set VPN and click Display.
Information about the BGP peer is displayed in the query result area.
Step 9 To view log information about a BGP peer, right-click a record in the query result area and
choose View Running Information > BGP Peer Log Information from the shortcut menu.
Step 10 In the BGP Peer Log Information dialog box, click Display.
Log information about the BGP peer is displayed in the query result area.
----End
Follow-up Procedure
The displayed running information about the BGP peer can be saved, copied, or searched as
follows:
: saves the information displayed in the query result area to a local disk as a TXT file.
: copies the information selected from the query result area to the clipboard.
: searches for the required information by keyword in the running information displayed in
the query result area.
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > OSPF Route > OSPF Process from the service tree.
Step 3 To view OSPF summary information, right-click a record in the query result area and choose
View Running Information > OSPF Summary Information from the shortcut menu.
To view the OSPF summary of a specified process, enter a value in the Process ID text box.
Step 5 To view OSPF LSDB information, right-click a record in the query result area and choose View
Running Information > OSPF LSDB Information from the shortcut menu.
Step 6 In the OSPF LSDB Information dialog box, set Link Type and click Display.
OSPF LSDB information is displayed in the query result area.
NOTE
To view the OSPF LSDB information about a specified process, enter a value in the Process ID text box.
Step 7 To view information about a virtual link, right-click a record in the query result area and choose
View Running Information > OSPF Virtual Link Information from the shortcut menu.
Step 8 In the OSPF Virtual Link Information dialog box, click Display.
Information about the virtual link is displayed in the query result area.
NOTE
To view virtual link information about a specified process, enter a value in the Process ID text box.
Step 9 To view error information, right-click a record in the query result area and choose View Running
Information > OSPF Error Information from the shortcut menu.
Step 10 In the OSPF Error Information dialog box, set Error Type and click Display.
OSPF error information is displayed in the query result area.
NOTE
To view error information about a specified process, enter a value in the Process ID text box.
----End
Follow-up Procedure
The displayed OSPF running information can be saved, copied, or searched as follows:
: saves the information displayed in the query result area to a local disk as a TXT file.
: copies the information selected from the query result area to the clipboard.
: searches for the required information by keyword in the running information displayed in
the query result area.
Prerequisites
Route management data must have been synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Route Management > IS-IS Route > IS-IS Process from the service tree.
Step 3 To view IS-IS summary information, right-click a record in the query result area and choose
View Running Information > IS-IS Summary Information from the shortcut menu.
To view IS-IS summary information about a specified process, enter a value in the Process ID text box.
Step 5 To view IS-IS summary information, right-click a record in the query result area and choose
View Running Information > IS-IS LSDB Information from the shortcut menu.
To view IS-IS LSDB information about a specified process, enter a value in the Process ID text box and
set Route Level.
----End
Follow-up Procedure
The displayed IS-IS running information can be saved, copied, or searched as follows:
: saves the information displayed in the query result area to a local disk as a TXT file.
: copies the information selected from the query result area to the clipboard.
: searches for the required information by keyword in the running information displayed in
the query result area.
Prerequisites
l MPLS management data must have been synchronized.
Context
l Disabling MPLS will delete all existing MPLS configurations from the NE. The MPLS
configurations include global configurations and configurations on interfaces. Exercise
caution with this operation.
l If you disable LDP on an NE, all LDP sessions associated with the NE's interfaces are
interrupted and all the LSPs based on these sessions are deleted.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > Global MPLS Configuration from
the service tree.
Step 5 In the LDP area, set the related parameters.See Setting LDP Parameters.
----End
Follow-up Procedure
To change an LSR ID, do as follows:
NOTICE
Disabling MPLS is involved in this operation. Disabling MPLS will delete all existing MPLS
configurations from the NE. The MPLS configurations include global configurations and
configurations on interfaces. Exercise caution with this operation.
1. Clear the selection of the Enable MPLS check box and click Apply.
2. Change the value of LSR ID to the required one and click Apply.
Prerequisites
l MPLS management data must have been synchronized.
l MPLS and MPLS LDP must have been enabled for NEs.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > Global MPLS Configuration from
the service tree. Then, click the LDP tab.
Step 4 On the General Information tab page, perform the following steps:
l In the LDP Dynamic Announcement area, set the related parameters.
l In the IGP LSP Trigger Policy area, set the related parameters.
l In the Enable Auto FRR area, set the related parameters.
l In the Backoff area, set the related parameters.
l In the Enable LDP MTU Signal area, set the related parameters.
l In the Enable Graceful Restart area, set the related parameters.
l In the LDP LSP Router Longest Match area, set the related parameters.
Step 5 Click the Peer Information tab and perform the following steps:
l In the LDP Remote Peer area, set the related parameters.
1. Select or clear the Prohibit label sending check box as required.
2. Select or clear the Enable Auto DoD check box as required.
3. In the LDP Remote Peer area, click Create.
4. In the dialog box that is displayed, set basic parameters and key communications
parameters for the remote peer.
5. Click Apply or OK.
NOTE
To modify existing parameters of a remote peer, select the remote peer and click Configure.
To modify existing parameters of a peer, select the peer and click Configure.
– Configure a peer group policy.
1. Click Create in the right pane of the peer group table.
2. In the dialog box that is displayed, set basic peer group parameters and other peer
group-related parameters.
3. Click Apply or OK.
NOTE
To modify existing parameters of a peer group, select the peer group and click Configure.
----End
Prerequisites
l The MPLS data of the NE must have been synchronized to the U2000.
l The MPLS, LDP, and MPLS TE capabilities must have been enabled for the NE.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > Global MPLS Configuration from
the service tree. Then, click the MPLS TE tab.
Step 5 Optional: In the RSVP-TE Hello area, set the related parameters.
Parameters in this area are extended RSVP-TE parameters. Setting these parameters helps to
detect reachability of RSVP neighboring nodes rapidly and support high-availability switchover
of RSVP-TE tunnels. If basic RSVP-TE configurations meet requirements, this step is optional.
1. Select the Enable RSVP-TE Hello check box, and set Hello Loss Times and Hello
Refresh Interval.
2. Select the RSVP-TE GR check box.
After selecting the RSVP-TE GR check box, you can set GR Basic Time as required.
3. In the Hello Session area, click Create. In the dialog box that is displayed, set LSR ID and
click OK.
Step 9 Optional: In the MPLS Auto FRR area, set the related parameters.
Enabling auto FRR helps to simplify manual configuration if multiple tunnels require protection.
If only a few tunnels require protection, manual configuration is applicable and this step is
optional.
Step 10 In the BFD For RSVP-TE area, set the related parameters.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > MPLS Interface from the service tree.
Step 3 Right-click in the blank area and choose Enable MPLS from the shortcut menu.
In this dialog box, you can also perform the following operations:
l Create some logical interfaces.
l Create some subinterfaces.
l Set interface details.
l Synchronize the data of the interface module.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > MPLS Interface from the service tree.
If the interface list is empty or the desired interface is not displayed in the list, enable MPLS for related
interfaces by referring to Enabling MPLS on Interfaces.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > MPLS Interface from the service tree.
If the interface list is empty or the desired interface is not displayed in the list, enable MPLS for related
interfaces by referring to Enabling MPLS on Interfaces.
Step 6 In the Label area, select the LDP label distribution mode.
Step 7 Optional: In the LDP Session Parameter area, set the related parameters.
This step is not required if LDP session-related parameters meet requirements.
1. In the Hello Packet Hold Time text box, enter a desired value.
2. In the Hello Packet Sending Time text box, enter a desired value.
3. In the Keepalive Packet Hold Time text box, enter a desired value.
4. In the Keepalive Packet Sending Time text box, enter a desired value.
5. Select a desired value from the LDP Transport Address drop-down list.
If Specific is selected, click the ... button and select an interface.
----End
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Configuration > MPLS Interface from the service tree.
If the interface list is empty or the desired interface is not displayed in the list, enable MPLS for related
interfaces by referring to Enabling MPLS on Interfaces.
4. Optional: In the Flooding Threshold area, set Up Threshold of Flooding and Lower
Threshold of Flooding.
Setting the flooding thresholds helps to prevent frequent flooding from causing bandwidth
waste. If the flooding thresholds are not set or the set flooding thresholds do not meet service
requirements, set parameters in the Flooding Threshold area.
5. Select an Auto FRR type from the Auto FRR drop-down list.
The parameters in the Enable RSVP-TE area are available only after MPLS TE is enabled.
1. Optional: In the RSVP Signaling area, set the related parameters.
a. Select the Enable RSVP-TE Hello check box to enable the extended RSVP Hello
mechanism on interfaces.
b. Select the Enable Summary Refreshing check box to enable the summary refreshing
function on interfaces.
----End
Prerequisites
l The MPLS data of the NE must be synchronized to the U2000.
l MPLS must be enabled on the related NE and interface.
l MPLS TE and MPLS RSVP-TE must be enabled on the related NE and interface.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > Tunnel Configuration from the service tree.
Step 3 On the Tunnel Configuration tab page, click Query to display all tunnels.
Step 4 Right-click in the query result area and choose Create from the shortcut menu.
Step 5 In the Create Tunnel dialog box, click the General Information tab and then set the general
parameters of the tunnel service.
NOTE
l The parameters on the General Information tab page are mandatory, whereas the parameters on other
tab pages are optional.
l If the selected NE does not support a certain feature, the parameters about this feature become
unavailable.
NOTE
If Signaling Type is set to Static CR, you can click Configure Static LSP to configure static tunnels. For
details, see 3.11.4 Creating a Static LSP Segment.
Prerequisites
l The MPLS data of the NE must be synchronized to the U2000.
l MPLS must be enabled on the related NE and interface.
Context
Static LSP segments are classified into two types: static LSP segments and static CR-LSP
segments.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > Static LSP Segment from the service tree.
Step 3 In the query condition area, click Query to display all static LSP segments.
Step 4 Right-click in the query result area and choose Add from the shortcut menu.
Step 5 In the dialog box that is displayed, set basic parameters for the static LSP segment.
Step 6 Click the Forward tab and set parameters for the forward LSP.
Step 7 Optional: Click the Backward tab and set parameters for the backward LSP. To create a
bidirectional static LSP, set parameters on this tab page.
----End
Prerequisites
l The MPLS data of the NE must be synchronized to the U2000.
l The working tunnel and protection tunnel must be available.
Context
The protection group is used in the following scenarios:
l When a fault occurs in the working tunnel, the MPLS OAM mechanism or another detection
mechanism switches traffic to the tunnel in the protection group after detecting the fault.
l Manually switch traffic from the working tunnel to the tunnel in the protection group.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > Protection Management from the service tree.
Step 3 Right-click in the query result area and choose Create from the shortcut menu.
You can also click Create on the Protection Management tab page.
Step 4 In the Create Protection Group dialog box, set the related parameters as required.
NOTE
When Protection Type is set to 1:1 and Switching Type is set to Double-Ended, the working and
protection tunnels must be configured as bidirectional tunnels.
----End
Prerequisites
l LDP sessions must be configured on the NE.
l The MPLS data of the NE must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Detection > LDP Session from the service tree.
The information about the sessions among the LDP peers is displayed in the query result area.
----End
Prerequisites
The MPLS data of the NE must be synchronized to the U2000.
Context
l The label FIB can be viewed only when the protocol type is STATIC, STATIC-CR,
LDP, or RSVP-TE.
l Label FIB stands for the label forwarding information base. The core LSR uses the label
FIB to forward labeled packets.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Detection > Label FIB from the service tree.
On the General tab page of the details area, the details about this label FIB are displayed.
----End
Counting LSPs
This topic describes how to count different types of LSPs on the current equipment.
Prerequisites
The MPLS data of the equipment must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > MPLS Detection > LSP Statistic from the service tree.
On the General tab page of the details area, the information such as the type and number of
currently collected LSPs is displayed.
----End
Prerequisites
The MPLS data of the NE must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > TE Tunnel Configuration from the service tree.
Step 3 On the TE Tunnel Configuration tab page, click Query to display all tunnels.
Step 4 Select the tunnel to be tested, right-click, and then choose LSP Ping or LSP Trace from the
shortcut menu.
----End
Prerequisites
The MPLS data of the NE must be synchronized to the U2000.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > TE Tunnel Configuration from the service tree.
Step 3 On the TE Tunnel Configuration tab page, click Query to display all tunnels.
Step 4 Right-click the tunnel to be reset and choose Reset from the shortcut menu.
Step 5 In the Confirm dialog box, click OK.
If the resetting is successful, the status bar prompts that the MPLS TE tunnel is successfully
reset.
----End
tunnel in advance and bandwidth is assigned to the protection tunnel. The working tunnel and
the protection tunnel form a protection group. If the working tunnel fails, data traffic is rapidly
switched to the protection tunnel.
Prerequisites
The MPLS data of the NE must be synchronized to the U2000.
Context
You can switch a protection group in either of the following modes:
l Clear: It is used to cancel the request of manually configuring switchover for the protection
group.
l Switch: It is used to manually switch traffic from the working tunnel to the protection tunnel,
or conversely, from the protection tunnel to the working tunnel.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose MPLS Management > Protection Management from the service tree.
Step 4 Right-click the protection group to be switched and choose Switch > Manually Switch from
the shortcut menu. Select the switching mode as required.
If the OAM protection group is successfully switched, the current operation is displayed in the
Switch Status column of the list, and the switching result is displayed in the Switch Result
column. If the switching of the OAM protection group fails, the system prompts failure causes.
----End
NOTE
After the LLDP alarm function is enabled, any of the following situation will trigger the equipment
to send alarm information to the U2000:
l The global LLDP function is disabled.
l The LLDP management address is changed.
l The neighbor information is changed. (No alarm information is generated on the local end if the
neighbor management address is changed.)
Prerequisites
l The related parameters must be set on the equipment.
l The data of the equipment must be synchronized to the U2000.
l The equipment must support the ability to configure LLDP globally.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > LLDP Management > LLDP Global Configuration from
the service tree.
Step 3 Set parameters such as Management IP Address, Interval for Message Transmission, and
Message Multiple.
NOTE
Unless necessary, keep the default parameter settings unchanged because modifying the settings may
increase the load of the system.
----End
Prerequisites
l The related parameters must be set on the equipment.
l The data of the equipment must be synchronized to the U2000.
l Configuring LLDP globally must be enabled on the equipment.
NOTE
By default, the LLDP function on interfaces is enabled after the global LLDP function is enabled.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose System Management > LLDP Management > LLDP Interface Configuration from
the service tree.
Step 3 On the LLDP Interface Configuration tab page, click Query. The interfaces supporting LLDP
after LLDP is globally enabled are displayed in a list.
Step 4 Right-click one or more interfaces that run LLDP and choose Enable or Disable from the
shortcut menu to apply the interface configurations to the equipment.
l If the status of the interfaces is Enabled, you can choose only Disable from the shortcut
menu.
l If the status of the interfaces is Disabled, you can choose only Enable from the shortcut
menu.
l If both Enabled and Disabled interfaces are selected, you can choose either Enable or
Disable from the shortcut menu. Then, the status of all the interfaces becomes the same as
the selected status.
----End
Prerequisites
The related parameters must be set on the equipment.
Procedure
Step 1 Right-click the NE in the Main Topology and choose Synchronize NE Data from the shortcut
menu.The LLDP neighbor information on the equipment is synchronized.
----End
Prerequisites
The data of the BFD management must be synchronized to the U2000.
Context
l Enabling BFD is a prerequisite to BFD configuration.
l If BFD is disabled, all BFD configurations will be deleted. Be cautions to disable BFD.
l To dynamically create LDP LSP service detection, you must set global MPLS BFD
parameters.
– LSPs are unidirectional. On an LSP, after the active party (the source end) creates a
BFD session and then sends an LSP ping packet, the passive party (the sink end) can
automatically create a BFD session only after receiving the LSP ping packet. The
passive party of an LSP is capable of automatically creating BFD sessions only when
the sink end of the LSP is enabled with the function of dynamically creating BFD
sessions. If this function is not enabled, the passive party cannot automatically create
BFD sessions.
– A BFD session is not created immediately after this function is enabled. Instead, it is
created after the sink end receives the BFD TLV-carried LSP ping request packet sent
from the source end.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > BFD Global from the service tree.
NOTE
l If single-hop BFD detection needs to be performed on the Layer 2 interfaces or the Layer 3 physical
interfaces without IP addresses, such as the IP-Trunk member interface and Layer 3 Eth-Trunk member
interface, adopt the default multicast IP address.
l You can set Default multicast address only when Enable BFD is set to Enable.
l If BFD Bind Type is set to Default multicast address, Default multicast address on the BFD
Global tab page cannot be modified.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > BFD Global TTL Configuration from the service
tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create BFD Global TTL Configuration dialog box, set Peer IP, Mask Length, Session
Type, and TTL Value.
The record of the created global TTL is displayed in the query result area.
----End
Prerequisites
l Service detection must be configured.
l The data of the BFD management must be synchronized to the U2000.
Context
Service detection supporting this function includes link detection, TE detection, VRF detection,
and PW detection.
The procedures for enabling and disabling the administrative status are similar for all types of
service detection. The following takes link detection as an example to describe the procedure.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > Link Detection
Configuration from the service tree.
Step 4 Select one or more BFD configuration records in the query result area.
Step 5 Right-click the selected records and choose Enable Administrative Status or Disable
Administrative Status from the shortcut menu.
NOTE
Batch operation is supported. If you select multiple BFD configuration records, a progress bar is displayed
showing the progress of enabling or disabling the administrative status. Finally, the operation result is
displayed in the Prompt dialog box.
NOTE
You need to perform this operation only when multiple BFD configuration records are selected for enabling
or disabling the administrative status of service detection.
----End
Prerequisites
l BFD must be globally enabled.
l Optional: The data of the interface information module must be synchronized to the
U2000.
NOTE
If Interface does not need to be bound to a local interface for configuring link detection,
synchronization of interface module information is not required.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > Link Detection
Configuration from the service tree.
Step 3 Click Create.
NOTE
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create Link Detection Configuration dialog box, set the related parameters.
----End
Prerequisites
l The VSI PW must exist.
l The data of the VSI management module must be synchronized to the U2000.
l BFD must be globally enabled.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > VSI PW
Detection Configuration from the service tree.
Step 3 Click Create.
l To create BFD detection for management VSIs, select Create Management VSI
Detection Task. In the dialog box that is displayed, set parameters.
l To create BFD detection for service VSIs, select Create Service VSI Detection Task. In
the dialog box that is displayed, set parameters.
Step 5 Click Query. You can query the VSI PW detection configurations.
----End
Prerequisites
l Before you configure BFD to detect an MPLS TE tunnel, the related tunnel interface must
be configured.
l BFD must be globally enabled.
Context
l BFD can detect only the TE tunnel whose signaling type is CR-Static or RSVP-TE.
l If the TE tunnel detected by BFD is in Down state and it can apply the OAM resource, a
BFD session can be established but cannot be Up.
l One tunnel may have multiple LSPs. In the case where a tunnel is detected through a BFD
session, the BFD session becomes Down only when all the related LSPs are faulty.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > MPLS TE
Detection Configuration from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create MPLS TE Detection Configuration dialog box, set the related parameters.
Step 6 Click Query. You can query the MPLS TE detection configurations.
----End
Prerequisites
l The data of the interface management module must be synchronized to the U2000.
l The data of the VRF management module must be synchronized to the U2000.
l The VRF must exist.
l BFD must be globally enabled.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > VRF Detection
Configuration from the service tree.
You can also right-click in the query result area and choose Create from the shortcut menu.
Step 4 In the Create VRF Detection Configuration dialog box, set the related parameters.
Step 6 Click Query. You can query the VRF detection configurations.
----End
Configuring PW Detection
This topic describes how to configure PW detection. The setup of BFD sessions based on PWs
helps to detect the link status of PWs between the local and remote PEs, thus reducing the impact
of link faults on services. You need to configure BFD sessions to detect the primary and
secondary PWs respectively.
Prerequisites
l The data of the interface management module must be synchronized to the U2000.
l The data of the PW management module must be synchronized to the U2000.
l The PW must exist.
l BFD must be globally enabled.
Context
l The VC of the PW to be detected must be created through the control word method.
l During PW detection, BFD must work in asynchronous mode. ATN only supports the
asynchronous mode. In addition, BFD sessions must be established at the local and peer
ends of the PW by binding the PW.
l If the PW can apply the OAM resource, When the PW is in Down state, a BFD session can
be established but cannot be Up.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > PW Detection
Configuration from the service tree.
Step 3 Click Create.
l Select Create Static BFD from the drop-down list. In the Create PW Detection
Configuration dialog box, set the related parameters.
l Select Create Dynamic BFD from the drop-down list. In the Create PW Detection
Configuration dialog box, set the related parameters.
----End
Prerequisites
l The data of the route management module must be synchronized to the U2000 and IS-IS
processes and IS-IS interfaces must be configured.
l BFD must be globally enabled.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > IS-IS Detection
Configuration from the service tree.
Step 3 On the IS-IS Detection Configuration tab page, click the IS-IS Process Configuration tab.
Step 5 In the Create IS-IS Process Detection dialog box, set the related parameters.
The record of the created dynamic IS-IS process detection is displayed on the IS-IS Process
Configuration tab page.
----End
Prerequisites
l The data of the route management module must be synchronized to the U2000 and IS-IS
processes and IS-IS interfaces must be configured.
l BFD must be globally enabled.
Context
You can create IS-IS interface BFD detection in the following cases:
l BFD needs to be configured on only certain interfaces rather than all the IS-IS processes
of an interface.
l IS-IS process BFD detection is configured but certain interfaces must use different BFD
sessions parameters to quickly discover link faults.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > IS-IS Detection
Configuration from the service tree.
Step 3 On the IS-IS Detection Configuration tab page, click the IS-IS Interface Configuration tab.
Step 5 In the Create IS-IS Interface BFD Detection dialog box, set the related parameters.
The record of the created IS-IS interface detection is displayed on the IS-IS Interface
Configuration tab page.
----End
Prerequisites
l The data of the route management module must be synchronized to the U2000 and BGP
peers or BGP peer groups must be configured.
l BFD must be globally enabled.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > BGP Detection
Configuration from the service tree.
Step 4 In the Create BGP Detection dialog box, set the related parameters.
NOTE
In the BGP Peer Configuration area, click Create and then set the related parameters to create a peer.
The record of the created BGP detection is displayed in the query result area.
----End
Prerequisites
l BFD must be globally enabled.
l The MPLS capability must be enabled and MPLS LDP must be configured on the NE.
l The sink end of the LSP must be enabled with the function of dynamically creating BFD
sessions.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection > LDP LSP Detection
Configuration from the service tree.
Step 4 In the Set Dynamic BFD Detect LDP LSP dialog box, set the related parameters.
The record of the configured LDP LSP detection is displayed in the query result area.
----End
Prerequisites
l BFD must be globally enabled.
l BFD sessions must be configured on OSPF interfaces.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Reliablity > BFD Management > Service Detection Configuration > OSPF
Detection Configuration from the service tree.
Information about BFD sessions configured on OSPF interfaces is displayed in the details area.
----End
Prerequisites
l Equipment must support the configurations of a discard policy.
l The configurations of QoS management are synchronized to the U2000.
Context
If a set of equipment does not exist in the service tree, it indicates that the equipment does not
support this feature.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose QoS Management > Discard Policy from the service tree.
Step 3 Right-click on the Discard Policy tab page and then choose Create from the shortcut menu, or
click Create on the Discard Policy tab page.
Step 4 In the Create Discard Policy dialog box, set the related parameters.
1. Enter the name of a discard policy to be created.
3. You can modify the lower limit, upper limit, and discard probability of the discard policy.
4. Click OK or Apply.
----End
Prerequisites
l Devices support the configurations of a flow queue policy.
l The configurations of QoS management are synchronized to the U2000.
Context
Each flow queue can be bound to a discard policy. If a flow queue is not bound to any discard
policy, packets are discarded in tail drop mode when the flow queue is full. To bind a flow queue
to a discard policy, create the discard policy before creating the queue profile.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management > HQoS, and then click Flow Queue Policy.
Step 3 Right-click on the Flow Queue Policy tab and then select Create on the shortcut menu, or click
Create on the Flow Queue Policy tab.
1. Enter the name of the flow queue policy to be created.
Step 4 In the Modify Flow Queue Policy Parameter dialog box, Click OK.
Step 5 In the Create Flow Queue Policy dialog box, Click OK or Apply.
----End
Prerequisites
l Devices support the configurations of a QoS profile.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click QoS Profile.
Step 3 Right-click on the QoS Profile tab and then select Create on the shortcut menu, or click
Create on the QoS Profile tab.
Step 4 In the Create QoS Profile dialog box, enter the name of a QoS profile to be created.
Step 5 Optional: Select the User Queue check box, and then set the parameter about User Queue.
Step 6 Optional: Or select the User CAR check box, and then set the parameter about User CAR.
----End
Prerequisites
l The related device supports the configurations of DS domain policies.
l The configurations of QoS management are synchronized to the U2000.
Context
If a device does not exist in the service tree, it indicates that the device does not support this
configuration.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click DS Domain Policy.
Step 3 Right-click on the DS Domain Policy tab and then select Create on the shortcut menu, or click
Create on the DS Domain Policy tab.
Step 7 Select a DS domain policy, and then click the Applying Object tab. Click Deploy.
Step 8 In the Deploy DS Domain Policy dialog box, click the ... button to select the interface to deploy
the DS domain policy.
----End
Prerequisites
l Interfaces of devices support the configurations of GTS parameters for the interface QoS.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click Configure Interface QoS.
Step 3 On the Configure Interface QoS tab, click Query to display the attributes of all interfaces.
Step 4 Select an interface QoS record, and then click the GTS tab.
Step 5 Select the GTS check box, and then set the values of PIR.
----End
Prerequisites
l The related device interface supports the deployment of applying policies for interface QoS.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click Configure Interface QoS.
Step 3 On the Configure Interface QoS tab, click Query to display the attributes of all interfaces.
Step 4 Select an interface QoS record, and then click the Applying Policy tab.
----End
Prerequisites
l The related device interface supports configuring the diffServ for interface QoS.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose QoS Management > Configure Interface QoS from the service tree.
Step 3 In the Configure Interface QoS window, click Query, attribute of all the interfaces is displayed.
Step 4 Select an interface QoS record, and then click the DiffServ tab.
Step 5 Select the Enable DiffServ check box and then do as follows:
l Set DiffServ Mode. At present, only Pipe is available.
l Set Service Class for packets sent from this interface.
----End
Prerequisites
The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click Configure Interface QoS.
Step 3 In the Configure Interface QoS window, click Query, attribute of all the interfaces is displayed.
Step 4 Select an interface QoS record and click the Other tab. Then, set the related parameters including
Enable 802.1p, Disable PHB, or IP URPF.
----End
Prerequisites
l The NMS server is installed with the performance component.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click Configure Interface QoS.
Step 3 On the Configure Interface QoS tab page, click Query to display the attributes of all interfaces.
Step 4 Right-click an interface record and choose Configure Performance Monitoring from the
shortcut menu.
----End
Prerequisites
l The NMS server is installed with the performance component.
l The configurations of QoS management are synchronized to the U2000.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand QoS Management, and then click Configure Interface QoS.
Step 3 On the Configure Interface QoS tab page, click Query to display the attributes of all interfaces.
Step 4 Right-click an interface record and choose Monitor Real-time Performance from the shortcut
menu.
----End
Prerequisites
l The QoS feature must support generation of QoS profiles.
l At least one QoS configuration deployed to NEs must exist.
Context
Generating a DS domain policy profile is taken as an example here.
The QoS features that support generation of QoS profiles are as follows:
l HQoS
– Flow Queue Policy
l Discard Policy
l QoS Profile
l DS Domain Policy
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose QoS Management > DS Domain Policy from the service tree.
Step 3 Select a DS domain policy, right-click, and choose Build Global Profile from the shortcut menu.
The Progress Control dialog box is displayed, indicating whether the operation is successful.
Step 4 Click Detail to view the detailed operation result. Click Close to close the dialog box.
----End
Follow-up Procedure
1. Choose Configuration > IP QoS Profile > DS Domain Profile from the main menu.
2. Then, you can view the generated global profile whose name is the same as that in original
QoS configurations.
Context
l By default, the system provides three authentication schemes, that is, default for Local-
RADIUS authentication, default0 for non-authentication, default1 for RADIUS
authentication. They can be modified but cannot be deleted.
l You can configure up to 16 authentication schemes in the system.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click Authentication Scheme.
Step 3 Right-click in the list and select Create on the shortcut menu.
----End
Context
l By default, the system provides two accounting schemes, that is, default0 and default1.
They can be modified but cannot be deleted.
l You can configure up to 16 accounting schemes in the system.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click Accounting Scheme.
Step 3 Right-click in the list and select Create on the shortcut menu.
----End
Context
l By default, the system provides an authorization scheme named default. You can modify
the default authorization scheme but you cannot delete it.
l You can configure up to 16 authorization schemes in the system.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click Authorization Scheme.
Step 3 Right-click in the list and select Create on the shortcut menu.
----End
Context
The ATN equipment manages RADIUS server through RADIUS server groups. A RADIUS
server group is a set of RADIUS servers that have the same attributes (excluding the IP addresses
and port numbers) and working in primary/secondary mode. The ATN equipment supports a
maximum of 16 RADIUS server groups.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click RADIUS Group.
Step 3 Right-click in the list and select Create on the shortcut menu.
On the Server Information tab page, set the related parameters. Then, click Save. To delete the server
information, click Clear.
----End
Context
The HWTACACS protocol is a security protocol developed on the basis of TACACS (RFC
1492). Compared with RADIUS, HWTACACS features more reliable transmission and
encryption, and is more suitable for security control.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click TACACS Templet.
Step 3 Right-click in the list and select Create on the shortcut menu.
NOTE
On the Server Information tab page, set the related parameters. Then, click Save. To delete the server
information, click Clear.
----End
Context
By default, the system provides one default domain, that is, default_admin. This domain is used
for the users whose management domains cannot be identified. The default domain can be
modified but cannot be deleted.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the service tree, expand User Access > BRAS Management > AAA Management, and then
click User Domain.
Step 3 Right-click in the list and select Create on the shortcut menu.
----End
The U2000 allows L2VPN and L3VPN configurations on NEs, including PW and PW template
management, PW PAS management, VSI and VRF management, and tunnel policy
management.
Prerequisites
l Interface configurations must have been synchronized. Tunnel interface and tunnels must
have been configured for NEs and run properly. That is, tunnels can send and receive
packets properly and tunnel interface are in the Up state.
l MPLS configurations must have been synchronized.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > Tunnel Policy Management from the service tree.
Step 3 Click Create, and set the name and tunnel policy type.
NOTE
The types of tunnel policies are Bind Application to Tunnel and Tunnel Selection Sequence. The two
are mutually exclusive.
Step 4 After completing the settings, click OK to return to the Tunnel Policy Management tab page.
The new tunnel policies will be displayed in the query result area.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > PW Template Management from the service tree.
Step 3 Click Create and set the related parameters.
----End
3.16.3 Creating a PW
This topic describes how to create a management PW, a service PW and an SPW on a per-NE
basis on a PE.
Creating a Service PW
This topic describes how to create a service PW. A PW is a virtual connection between two PEs
and is used to transmit frames between the PEs. You can create a static or dynamic PW, and you
also can creat a static or dynamic PW in the primary/secondary relationship.
Prerequisites
Before configuring a static PW, you must do as follows:
l Configure IGP for PEs and Ps on the MPLS backbone network to implement IP connectivity
of the backbone network.
l Enable MPLS on PEs.
l Establish the tunnel of a corresponding type between the PEs according to the applied tunnel
policy.
l When the CE access type is VLAN, configure subinterfaces on PEs; when the CE access
type is ATM, configure VCs on PEs.
l Before configuring the MPLS L2VC connection, enable MPLS L2VPN.
Before configuring a dynamic PW, you must do as follows:
l Configure IGP for PEs and Ps on the MPLS backbone network to implement IP connectivity
of the backbone network.
l Enable MPLS on the backbone network.
l Establish the tunnel of a corresponding type between the PEs according to the applied tunnel
policy.
l Set up a remote LDP session between PEs.
l When the CE access type is VLAN, configure subinterfaces on PEs; when the CE access
type is ATM, configure VCs on PEs.
l Before configuring the MPLS L2VC connection, enable MPLS L2VPN.
Before configuring a secondary PW, you must do as follows:
l Configure IGP for PEs and Ps on the MPLS backbone network to implement IP connectivity
of the backbone network.
l Enable MPLS on the backbone network.
l Establish the tunnel of a corresponding type between the PEs according to the applied tunnel
policy.
l Establish tunnels used by the primary and secondary PWs between PEs in the primary and
bypass paths, including the CR-LSP, LSP, and GRE tunnels.
l If the tunnel is a GRE or CR-LSP tunnel, configure a tunnel policy. If the tunnel is an LSP
tunnel, configure a tunnel policy.
l Configure the primary PW on the PEs of the primary path.
l Set IP addresses for CE access interfaces.
NOTE
l One interface cannot be configured as the AC interface of an L2VPN and as the AC interface of an
L3VPN at the same time. When an interface is bound to an L2VPN, all the Layer 3 features configured
on the interface, such as the IP address and routing protocol, are invalid.
l PWE3 does not support P2MP. When you create an MPLS L2VC on an ATM subinterface, the ATM
subinterface must be the end-to-end type. For the configuration of the transparent transmission of ATM
cells, however, the restriction is not applicable.
l You can configure the primary and secondary static PWs or dynamic PWs. The types of the primary
and secondary PWs must be consistent. That is, the encapsulation types of the primary and secondary
PWs must be consistent.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > PW Management from the service tree.
Step 3 On the PW Management tab page, click Create and select Service PW from the drop-down
list.
1. Click the Interface Configuration tab, and then set the values of Interface Name and
Signaling Mode.
2. Click the General tab. Then, set corresponding parameters.
NOTE
The following takes the Dynamic signaling as an example. The parameters to be configured on the
General tab page vary according to the interface types and signaling types on the Interface
Configuration tab page. The parameters unsupported are hidden.
Step 4 After the settings, click OK to return to the PW Management tab page.
The created PWs are displayed in the query result area.
Step 5 Optional: For existing dynamic PWs, you can perform the following configurations:
1. Click Configure. The Modify Service PW dialog box is displayed.
2. Click Advance on the General tab page to set advanced PW parameters.
----End
Creating a PW APS
This topic describes how to create a Pseudo Wire (PW) Automatic Protection Switching (APS).
PW APS is a network protection mechanism. This mechanism is used to switch services to the
secondary PW when the primary PW fails to function properly.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > PWE3 Management > PW APS Management from the service
tree.
----End
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > PW APS Management from the service tree.
Step 4 In the dialog box that is displayed, set the related parameters.
----End
Result
Information about the created PW APS protection group is displayed in the query result area.
Prerequisites
Before configuring the Martini service VSI, complete the following tasks:
l Configuring LSR IDs and enabling MPLS and MPLS LDP on PE and P equipment
l Enabling MPLS L2VPN on PEs
l Establishing tunnels between PEs to transmit user data
l If PEs are not directly connected to each other, that is, if PEs have to communicate with
each other by using Ps, remote LDP sessions must be configured.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > VSI Management from the service tree.
Step 3 Choose Create > Martini Service VSI. The Create Martini Service VSI dialog box is
displayed.
1. On the Configure VSI tab page, set the related parameters.
NOTE
The VSI parameters that need to be set vary according to equipment types.
2. On the Configure VC tab page, click Create and select the VC type as required.
NOTE
The commands delivered by and the function of the mesh VC are different from those of the spoke
VC The mesh VC is applicable to the full-mesh scenario, whereas the spoke VC is applicable to the
HVPLS. The essential difference between the mesh VC and the spoke VC is whether to forward
packets received from the PW to another VSI. The spoke VC forwards the packets, whereas the mesh
VC does not.
3. On the Bind Interface tab page, click Add. In the Select Interface dialog box, select the
access interface associated with the VSI, and then click OK.
NOTE
l You cannot select the interfaces that are bound to other services.
l If no eligible interfaces are displayed, you can click Create to create an interface or subinterface.
4. On the MAC Address Entry tab page, click Create. In the dialog box that is displayed,
set the related parameters.
----End
Result
On the VSI Management tab page, you can find the newly created Martini service VSI. You
can select the VSI and view details about the VSI in the detailed information area.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > VSI Management from the service tree.
Step 4 Click the VSI List tab. Select one or more VSIs to be operated from the service VSI list. Then
perform either of the following operations:
l Right-click the VSIs and choose Enabled from the shortcut menu.
l Right-click the VSIs and choose Disabled from the shortcut menu.
----End
Prerequisites
Before configuring a VRF, you must do as follows:
l Create routing policies if import or export routing policies need to be applied to the VRF.
l Create tunnel policies if MPLS TE tunnels are configured. For configurations about tunnel
policies, see "Creating a Tunnel Policy".
Context
A VRF is also called a VPN instance. One or more VRFs and a public routing table (global
routing table) can be maintained for a PE. VRFs are separate from each other. A VRF can be
regarded as a virtual router, which maintains the independent address space and provides access
interfaces.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose VPN Management > VRF Management from the service tree.
Step 4 In the Create VRF dialog box, perform the following tasks:
1. On the VRF Configuration tab page, enter the VRF name, RD, and VRF description.
2. Click Create. In the Create RT dialog box, set the RT value and type. Click OK.
3. Optional: Click Advanced. In the Configure Advanced Attribute of VRF dialog box,
set the related parameters. Click OK.
4. On the Bind Interface tab page, click Add. In the Select Interface dialog box, set the
query conditions and click Query. Select the interface that is bound to the VRF, and then
click OK.
NOTE
----End
Result
The created VRF is displayed in the query result area in VRF Management. You can select the
VRF and view details about the VRF in the detailed information area. The details about the VRF
includes the general information and information about the bound interface.
Prerequisites
Before configuring a CCC connection, you must do as follows:
l Configure the basic MPLS capability on the PE.
l Enable MPLS L2VPN on the PE.
l Configure the interface connecting a PE to a CE, that is, the AC interface.
– When the CE access type is VLAN, configure subinterfaces on the PE.
– When the CE access type is ATM, configure VCs on the PE.
– When the CE access type is FR, configure DLCIs on the PE.
Procedure
Step 1 Right-click the ATN in the Main Topology and choose ATN Explorer from the shortcut menu.
Step 2 Choose VPN Management > CCC Management from the service tree.
Step 4 Set parameters in the dialog box shown in the following figure.
NOTE
l Incoming Interface indicates the PE's interface that is connected to the first CE.
l Outgoing Interface indicates the PE's interface that is connected to the second CE.
----End
3.17.1 Ping
This topic describes how to send ping packets to a remote host to check whether it is reachable.
To check the network connectivity or the line quality, you can also perform the ping test.
Context
During the ping process, the source host sends an ICMP ECHO-REQUEST packet to the
destination host. If the network connection between the source host and the destination host is
normal, after receiving the ICMP ECHO-REQUEST packet, the destination host responds to
the source host with an ICMP ECHO-REPLY packet.
Procedure
Step 1 In the Main Topology, select the NE to be operated.
Step 2 Right-click the NE and choose Tool > Ping from the shortcut menu.
Step 3 In the dialog box that is displayed, select Ping or Continual Ping, and then click Start.
----End
Result
l If the operation is successful, it indicates that the destination host is reachable. In the
Result area, the information indicating the normal connection is displayed. The information
includes the number of sent packets, number of received response packets, percentage of
no-response packets, and minimum, maximum, and average response time.
l If the operation fails, it indicates that the destination host is unreachable and the network
connectivity or line failure cannot be detected. The Request time out message is displayed.
3.17.2 Tracert
This topic descries how to test the route that a data packet passes from the source host to the
destination host. The tracert command is used to check whether a network connection is
reachable and to determine the position where a fault occurs. After detecting a fault on the
network by using the ping command, you can use the tracert command to determine the fault
position.
Context
The execution process of the tracert command is as follows:
l The source host sends a packet whose TTL is 1. The TTL times out. The first hop sends
back an ICMP error message to indicate that this packet cannot be sent.
l The source host sends a packet whose TTL is 2. The TTL times out. The second hop sends
back an ICMP error message to indicate that this packet cannot be sent.
l The source host sends a packet whose TTL is 3. The TTL times out. The third hop sends
back an ICMP error message to indicate that this packet cannot be sent.
l The process continues in this manner until the packet reaches the destination host or a packet
times out whose TTL is 10.
The purpose of performing these operations is to record the source address of each ICMP TTL
time-out message, so as to provide the route that an IP packet passes to reach the destination
host.
Procedure
Step 1 In the Main Topology, select the NE to be operated.
Step 2 Right-click the NE and choose Tool > Tracert from the shortcut menu.
NOTE
In the Tracert Result dialog box, the gateways that the test packets pass from the source host to the
destination host and the response time that the three sent test packets reach the gateways are displayed.
----End
3.17.3 Telnet
This topic describes how to remotely log in to an NE by performing the Telnet operation on the
U2000 to configure and maintain the NE.
Prerequisite
Make sure that port 9811 between the U2000 server and clients is enabled before you telnet a
device.
The button on the toolbar is grayed out. It is available only after you access NE Explorer.
2. Right-click and choose NE Explorer from the shortcut menu.
The NE Explorer is displayed.
3.17.4 SSH
This topic describes how to guarantee the security of network communications through SSH
that provides authentication, encryption, and authorization. When a user remotely logs in to a
router through an insecure network, SSH offers secure information guarantee and powerful
authentication to protect the NE against attacks such as IP address spoofing and interception of
plain text passwords.
2. Right-click the NE and choose Tool > SSH from the shortcut menu.
3. In the dialog box that is displayed, set related parameters and click OK.
After logging in to a remote server or host remotely, you can perform operations on the NE
through command lines.
The button on the toolbar is grayed out. It is available only after you access NE Explorer.
2. Right-click and choose NE Explorer from the shortcut menu.
The NE Explorer is displayed.
Context
l Compared with the common ping test, the ICMP ping test supports the setting of test packet
parameters and other advanced parameters, as well as the setting of the source and
destination addresses. Thus, the ICMP ping test can provide more specific test results.
l Certain NEs do not support the ICMP ping test. The ICMP Ping option is not contained
in the shortcut menus for these NEs.
Procedure
Step 1 Right-click the source NE to be diagnosed in the Main Topology and choose Tool > ICMP
Ping from the shortcut menu.
Step 2 At the moment, the cursor turns into a cross. Click the destination NE.
Step 5 View the execution result in the Run Test dialog box.
During the test execution, you can click Terminate to stop the test.
----End
Context
l Compared with the common tracert test, the ICMP trace test supports the setting of test
packet parameters and other advanced parameters, as well as the setting of the source and
destination addresses. Thus, the ICMP trace test can provide more specific test results.
l Certain NEs do not support the ICMP trace test. The ICMP Trace option is not contained
in the shortcut menus for these NEs.
Procedure
Step 1 Right-click the source NE to be diagnosed in the Main Topology and choose Tool > ICMP
Trace from the shortcut menu.
Step 2 At the moment, the cursor turns into a cross. Click the destination NE.
Step 5 View the execution result in the Run Test dialog box.
During the test execution, you can click Terminate to stop the test.
----End
Procedure
l Basic configurations
All basic configurations are applied to NEs using the IP plug-and-play management
function. Basic configurations include basic device configurations, AAA and user
management, loopback interface configuration, network interface configuration, and
SNMP configurations.
l IGP configurations
All IGP configurations are applied to NEs using the IP plug-and-play management function.
IGP configurations include global routing configuration, interface route and IP and routing
policies.
l MPLS configurations
LSP Deployment Mode Data application using the IP Plug and Play
function
LSP Deployment Mode Data application using the IP Plug and Play
function
Tunnel Policy
----End
Configuration Principle
If IGP routes are deployed and the cost value is configured as planned on a network, route
selection can be controlled. In this case, MPLS LDP LSPs of the host on the network can be
triggered based on the routing table.
Data Planning
This topic provides the data plan for MPLS LDP configuration.
ASG4 4.4.4.4
RSG5 5.5.5.5
RSG6 6.6.6.6
Configuration Object
Configure BFD for LSP on the primary and secondary ASGs and the primary and secondary
RSGs on a bearer network.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the Service Tree, choose Reliability > BFD Management > Service Detection
Configuration > LDP LSP Detection Configuration from the main menu.
Step 3 Click Configure. The Set Dynamic BFD Detect LDP LSP Detection dialog box is displayed.
Step 4 Select Enable Dynamic BFD for LDP LSP Detection and Set Dynamic BFD Detect LDP
LSP Trigger Policy, and set Trigger Type to FEC List.
Step 5 Click ... next to FEC List. The Set FEC List dialog box is displayed. Enter the FEC list name,
click New, enter Peer IP Address, and click Apply. The following table lists the data plan for
NE parameters.
----End
Deploying MPLS TE
This topic describes how to deploy Multi-Protocol Label Switching Traffic Engineer (MPLS
TE) to create TE tunnels for carrying services.
Configuration Principle
This topic describes the principle for configuring layered MPLS TE tunnels.
As shown in Figure 4-1, deploy MPLS TE tunnels to carry MPLS VPN for transport wireless
services.
NOTE
In the preceding figure, A to E indicate TE constraint interfaces for TE1 to TE7 respectively.
TE1 A Loose
TE2 B Loose
TE3 C Loose
TE4 B Loose
TE5 D Loose
TE6 D Loose
TE7 E Strict
– Configure the tunnel re-optimization function. You are advised to set the re-
optimization interval to 3600s.
NOTE
If the secondary LSP of a tunnel is not configured with constraint paths, a best-effort path is not
required for the tunnel. Otherwise, a best-effort must be configured for the tunnel.
l Automatic path selection: Properly plan cost values for links and use the TE CSPF
function to automatically select paths. In this mode, tunnel deployment is simple and
network adjustment is easy. On a network with a clear structure, use automatic path
selection. The configuration principle is as follows:
– TE automatic path selection is implemented based on IGP routes. Therefore,
configure the cost values according to the network plan when configuring IGP. For
details on IGP cost values, see the related IGP configuration topic.
– To ensure that services are transmitted over the best path, configure the tunnel re-
optimization function. You are advised to set the re-optimization interval to 3600s.
– To maximum protection for the working path of tunnels configured with hot-
standby, configure the CR-LSP overlap-path function.
For TE to automatically select proper paths, plan cost values for links. To ensure the
primary TE LSPs select the paths of the rings,the access link between the master and
slave ASGs must have a higher cost value than the maximum metric value of the access
ring. For example, cost values for links a, b, c, and d in the following figure must meet
the following rule: (cost(a) + cost(b) + cost(d)) < cost(c). In addition, set the cost values
for links between the master and slave NPEs based on the following rules: (n - 1) x 10
< cost < n x 10 (for IS-IS); (n - 1) < cost < n (for OSPF); where n is the number of links
on the aggregation ring, excluding the link between RSGs. The figure below shows an
example of cost value plan for this example.
l Create tunnels TE3 and TE4 as the VPN backup tunnels for the VPN working
tunnel TE1 or TE2.
NOTE
When Ethernet and ATM/TDM services share tunnels, the services can also share tunnel policies as
in this example. If Ethernet and ATM/TDM services do not share tunnels, tunnel policies need to be
configured for the services respectively.
6. Create a tunnel policy.
Specify CR-LSP tunnels as the tunnels to be selected first.
Context
You need to create multiple templates based on different requirements for tunnel settings.
NOTE
Path Constraint in the following table applies to the primary tunnel only.
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to RSVP-TE Tunnel and click
Filter.
Step 3 In the Manage Service Template window, click Create > RSVP-TE Tunnel Template.
Step 4 In the Create RSVP-TE Tunnel Template window, set Template Name as planned. The
following table lists the planned template parameters.
TE Information
Trail Information
Reversion Interval(s) 60
BFD Information
NOTE
The check box needs to be selected only when you configure the templates for the primary VPN tunnel on
the access ring or all tunnels on the aggregation ring.
DetectMultiplier 3
MinReceiveSendInterval 50
DetectMultiplier 3
MinReceiveSendInterval 10
Advanced—>Setup Attribute
Advanced—>Reoptimization
Interval(s) 3600
----End
Configuration Object
On the bearer network, configure seven MPLS TE tunnels for service bearer and protection
according to the data plan.
Procedure
Step 1 Create tunnels.
Choose Service > Tunnel > Create Tunnel from the main menu.
Reverse Tunnel When the Create Reverse Tunnel function is enabled, the U2000
Name automatically sets Reverse Tunnel Name to Tunnel Name+_RVS.
NOTE
The Yes check box beside Create Reverse Tunnel is selected by default.
Step 3 Add source and sink NEs according to the data plan.
In Physical Topology, right-click source and sink NEs respectively.
NOTE
If requiring the forward and reverse tunnels to constrain different interfaces, you need to configure
constrained interfaces respectively for both tunnels.
3. In the dialog box that is displayed, select the interface traversed by the primary forward
path and click OK.
NOTE
Click Show all Interface and select an interface from all interfaces on the current NE.
4. In the Route Constraint area, set Restriction Type on the Forward tunnel primary
trail and Reverse tunnel primary trail tabs. Restriction Type is set to Loosely include
by default. However, you need to set it to Strictly include for tunnels between the primary
and secondary RSGs.
Step 6 After the tunnels are created successfully, the Operation Result dialog box is displayed. Click
Browse Trail to view the tunnel configuration results. Running Status is Up, Alarm
Severity is Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
----End
Verifying Configurations
This topic explains how to verify configurations.
LSP Ping
1. Choose Service > Tunnel > Manage Tunnel from the main menu.
2. In the Set Filter Criteria dialog box, set the search criteria and click Filter. The qualified
tunnels are displayed.
3. Select a tunnel. In the tunnel topology displayed in the lower area, right-click the tunnel
and choose Fast Diagnose from the shortcut menu.
4. In the LSP Ping dialog box, click Run.
5. View the test results in the Detail area.
6. Repeat the preceding steps to check whether LSP Ping can be successfully performed for
the rest of the tunnels.
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to L3VPN and click Filter.
Step 3 In the Manage Service Template window, click Create > L3VPN Service Template.
Step 4 In the Create L3VPN Service Template window, set Template Name as planned. The
following table lists the planned template parameters.
Control
General
VRF ID Auto-Assign
Import RT N/A
Export RT N/A
Priority 60
Description N/A
VRRP ID N/A
Lock N/A
----End
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to PWE3 and click Filter.
Step 3 In the Manage Service Template window, click Create > PWE3 Service Template.
Step 4 In the Create PWE3 Service Template window, set Template Name as planned. The following
table lists the planned template parameters.
General
Remarks N/A
Working PW—>Advanced
Encapsulated Frames 8
Protection PW—>Advanced
Encapsulated Frames 8
SAI
BFD Configuration
Detection Multiple 3
OAM Mapping
Operation Attribute
Deploy Deploy
Enable Enable
General
Remarks N/A
Working PW—>Advanced
Protection PW—>Advanced
SAI
BFD Configuration
Detection Multiple 3
OAM Mapping
Operation Attribute
Deploy Deploy
Enable Enable
----End
Configuration Object
Set Max.ATM Cells on the cell site gateway (CSG) and on the primary and secondary radio
service gateway (RSGs).
Procedure
1. In the Main Topology, right-click the desired NE and choose NE Explorer from the
shortcut menu.
2. Choose VPN Management > PWE3 Management > PW Template Management from
the Service Tree.
3. Click Create. The Create PW Template dialog box is displayed.
4. Set the PW template name according to the data plan.
5. Set Control Word to Yes.
6. Set Max.ATM Cells to 1.
NOTE
When ATM subboards do not support cascading, the maximum number of ATM cells should be set to 1.
7. Click OK.
Configuration Guidelines
This topic describes the guidelines for deploying hierarchical BGP/MPLS VPN and protection
(BGP is short for Border Gateway Protocol, MPLS is short for multiprotocol label switching,
and VPN is short for virtual private network).
Figure 4-5 shows the hierarchical GP/MPLS VPN between cell site gateways (CSGs) and
Remote site gateways (RSGs).
1. Deploy MP-IBGP.
l Establish MP-IBGP peer relationships between CSGs and the master ASG, and between
the master ASG and the master RSG.
l To protect the master ASG, establish MP-IBGP peer relationships between CSGs and
the backup ASG, and between the backup ASG and the master RSG.
l To protect the master RSG, establish an MP-IBGP peer relationship between the master
ASG and the backup RSG.
2. Deploy VPN services.
An MBB network supports the following types of Ethernet services:
l E2E Ethernet services: transmitted between NodeBs/eNodeBs and RNCs/MMEs/S-
GWs.
l Local switching Ethernet services: carried between different NodeBs/eNodeBs, such as
LTE X2 services.
In practical deployment, the HVPN solution can be implemented in two modes based on
CSG performance and customer requirements:
l H-VPN: CSGs receive all specific routes.
l HoVPN: CSGs receive only default routes or aggregated routes.
3. Configure service protection switching.
l Enable NSR on the entire network. This is to ensure that BGP peer relationships are not
interrupted during a master/backup device switchover and speed up IBGP route
convergence.
l Increase the ConnectRetry interval for re-establishing the BGP peer relationship
between a CSG and the master ASG.
This configuration allows the BGP peer relationship to be established between the CSG
and the master ASG after the BGP peer relationship has been established between the
recovered master ASG and the master RSG during LTE X2 service deployment.
l Configure VPN FRR or BFD for BGP.
VPN FRR is recommended. If no VPN instance is created on the deployed devices,
configure BFD for BGP and IP over TE to speed up the master/backup device
switchover.
4. RSG protection can be implemented using VRRP (recommended) or Active and standby
routes.
l Configure VRRP (recommended).
To protect the links between RSGs and the MBB core, configure VRRP over VLANIF
between the master and backup RSGs.
a. Configure the interfaces that connect the master and backup RSGs and the
interfaces that connect the master and backup RSGs to the RNC to be Layer 2
switch interfaces, and add these interfaces to a VLAN.
b. Create a VLANIF interface on the master and backup RSGs and configure VRRP
over VLANIF.
c. Configure BFD between the master and backup RSGs to check Layer 2 links and
remote private network addresses. This is to speed up the master/backup device
switchover.
d. Configure VRRP switchback delay on the master RSG. If VRRP switchback delay
is not configured, both NEs may be in the master state during VRRP switchback.
This will result in packet loss.
l Active and standby routes: Configure active and standby static routes to implement RSG
protection. The RNC communicates with the master and backup using logical interfaces.
The logical interfaces connected to the master and backup RSGs can both receive
packets.
Data Plan
Before using the configured BGP/MPLS VPN to carry the Ethernet service, you need to plan
key parameter settings.
SAI CSG1/CSG2: -
Ethernet0/3/0.100, vlan 100
Configuration Objects
All the main interfaces that connect RSGs or connect the RSGs and the RNC side must be
configured as Layer 2 interfaces.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 4 Select the interface to be configured and click Configure. A dialog box is displayed.
Step 5 If the interface is an Ethernet port, click the Ethernet Feature tab, select Layer 2, and click
OK.
Step 6 If the interface is an Eth-Trunk port, click the Physical Feature tab, select Layer 2, and click
OK.
Step 7 Configure other interfaces by referring to steps 1-6.
----End
Configuration Object
Configure the CSG, primary and secondary aggregation site gateways (ASGs), and primary and
secondary RSGs to create the L3VPN service.
1. Choose Service > L3VPN Service > Create L3VPN Service from the main menu.
2. Configure service information.
3. In the Physical Topology, right-click an NE and choose a node role from the shortcut menu.
After the configuration, the NE is displayed in Node List in the lower-left part.
NOTE
f. On the VLAN Member Port tab, click Add. Then the Add Member Port dialog box
is displayed.
g. Select ports from Available Port and click to add ports to the Selected
Port list.
h. In the Selected Port list, set Binding Mode to Passable VLAN for the two ports as
listed in the following table, and click OK.
a. On the VRF Configuration tab, choose Route Configuration > Static Route >
Static Route Object.
Mask 255.255.255.255
10. (Optional) Configure the VRRP (required only when the VRRP protection is used).
a. Click the Service Topology tab.
b. In the topology view, right-click the VALNIF interface extended from the RSG and
choose Expand from the shortcut menu.
c. Right-click the expanded VLANIF interface and choose Create VRRP from the
shortcut menu. The Configure VRRP dialog box is displayed.
VR IP 192.168.2.100 192.168.2.100
Delay(s) 180 0
Notification Interval(s) 30 30
Increase Priority By 40 40
e. Click the Track BFD option button and Con. The Configure BFD dialog box is
displayed. Set parameters according to the data plan.
Min.Receiving Interval 50 50
Min.Sending Interval 50 50
f. After the BFD configuration is complete, click OK in the Configure BFD dialog box.
g. In the Configure VRRP dialog box, click OK.
11. In the Create L3VPN Service window, click Apply to apply the L3VPN service.
12. After the L3VPN service is applied successfully, the Operation Result dialog box is
displayed.
13. Click Browse Trail to view the L3VPN configuration results.
Running Status is Up, Alarm Severity is Normal, Deployment Status is Deployed, and
Enabling Status is Enabled.
NOTE
To view the path carrying the L3VPN service, perform the following operations:
In the Manage L3VPN Service window, select the created L3VPN service, and click Refresh on the
Service Link tab to view the path data or click the Topology tab to view the path in the Service
Topology.
NOTICE
If Running Status is not Up, right-click the L3VPN service, choose Refresh Running
Status from the shortcut menu, and view Running Status.
a. On the VRF Configuration tab, choose General > Label Distribution Policy
and set Label Distribution Policy to Per VPN.
b. On the VRF Configuration tab, choose General > Routing Policy > Routing
Policy Object > Routing Policy.
c. Double-click in the cell at the intersection of each NE column and the Routing
Policy row, and click .... The Select Routing Policy dialog box is displayed.
d. Click Create. In the Create Policy dialog box, set parameters.
Node ID 10
f. Click Create in the lower pane. In the Create Policy Rule dialog box, set
parameters.
Behavior Apply
Configuration Object
Configure the CSG and primary and secondary RSGs to create the L3VPN service.
1. Choose Service > L3VPN Service > Create L3VPN Service from the main menu.
2. Configure service information.
3. In the Physical Topology, right-click an NE and choose a node role from the shortcut menu.
After the configuration, the NE is displayed in Node List in the lower-left part.
NOTE
d. Click the IP Address tab and set the IP address and mask for the subinterface.
f. On the VLAN Member Port tab, click Add. Then the Add Member Port dialog box
is displayed.
g. Select ports from Available Port and click to add ports to the Selected
Port list.
h. In the Selected Port list, set Binding Mode to Passable VLAN for the two ports as
listed in the following table, and click OK.
c. Select a physical interface in use and click Configure. In the Configure Ethernet
Interface dialog box, click the Physical Feature tab, and set Delay Time(ms) to
300000.
d. Click OK to dismiss the Configure Ethernet Interface dialog box.
e. Click OK to select an interface.
8. (Optional) Configure static routes.
NOTE
l If the base station uses a logical IP address, configure a static route destined to this logical IP address
on the CSG and bind the static route to a VPN instance.
l If the RNC uses a logical IP address, configure a static route destined to this logical IP address on the
RNC and bind the static route to a VPN instance.
a. On the VRF Configuration tab, choose Route Configuration > Static Route >
Static Route Object.
Priority 60 5 5
10. (Optional) Configure the VRRP (required only when the VRRP protection is used).
a. Click the Service Topology tab.
b. In the topology view, right-click the VALNIF interface extended from the RSG and
choose Expand from the shortcut menu.
c. Right-click the expanded VLANIF interface and choose Create VRRP from the
shortcut menu. The Configure VRRP dialog box is displayed.
VR IP 192.168.2.100 192.168.2.100
Delay(s) 180 0
Notification Interval(s) 30 30
Increase Priority By 40 40
e. Click the Track BFD option button and Con. The Configure BFD dialog box is
displayed. Set parameters according to the data plan.
Min.Receiving Interval 50 50
Min.Sending Interval 50 50
f. After the BFD configuration is complete, click OK in the Configure BFD dialog box.
To view the path carrying the L3VPN service, perform the following operations:
In the Manage L3VPN Service window, select the created L3VPN service, and click Refresh on the
Service Link tab to view the path data or click the Topology tab to view the path in the Service
Topology.
NOTICE
If Running Status is not Up, right-click the L3VPN service, choose Refresh Running
Status from the shortcut menu, and view Running Status.
Node ID 10
f. Click Create in the lower pane. In the Create Policy Rule dialog box, set
parameters.
Behavior Apply
1. Choose Service > L3VPN Service > Create L3VPN Service from the main menu.
2. Configure service information.
Parameter Value
VRF ID Auto-Assign
3. Click Add and choose SPE Node. In the dialog box that is displayed, select the primary
and secondary aggregation site gateways (ASGs) and click OK.
4. Click Add and choose UPE Node. In the dialog box that is displayed, select the primary
and secondary CSGs and click OK.
5. Click Details. On the VRF Configuration tab, set basic attributes according to the data
plan.
NOTE
The RT varies according to MPLS LDP LSPs or MPLS TE tunnels. For details about variance, see Data
Plan. This topic uses MPLS TE tunnels as an example.
6. Configure service access interfaces on CSGs.
a. Double-click in the cell at the intersection of the CSG column and the Interface row,
and click .... In the dialog box that is displayed, select a service access interface
according to the data plan, set its IP address, and click OK.
a. On the VRF Configuration tab, choose Route Configuration > Static Route >
Static Route Object.
Configuration Object
Configure the primary and secondary RSGs that are located on the bearer network.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management VLAN ManagementPort VLAN Management from
the service tree.
Step 5 In the Modify VLAN Attribute of Port dialog box, set Port Link Type to a required value.
----End
Configuration Object
The primary and secondary RSGs.
Configuration Procedure
1. (Optional)Configure BFD for detecting the peer RSG. (This operation is required only if
RSGs have a 10GE link between them.)
a. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
b. In the Set Filter Criteria dialog box, click Filter.
c. Select the desired service, right-click, and choose Configure BFD from the shortcut
menu.
d. In the BFD Session Configuration Management window, click Create.
e. Set BFD detection path to the link between the primary and secondary RSGs.
f. Click Configure on the right of BFD session.
g. Set Bound Service Type to IP Link.
h. Set other parameters according to data plan.
i. Double-click the Detection Object text box, then click Configure that is displayed.
In the dialog box that is displayed, set IP bind type to Default multicast address,
and set the physical interface between RSGs as the outgoing interface according to
data plan.
j. Click OK.
k. Click OK to dismiss the Configure BFD Session dialog box.
l. Click OK and create a BFD session.
2. (Optional)Configure a static route.
NOTE
If the RNC uses a logical address, the static route should destined to the logical address. In addition, the
static route must be referenced by VPN instances.
a. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
b. In the Set Filter Criteria dialog box, click Filter.
c. Select a service to be configured, and click Modify.
d. On the VRF Configuration tab, expand Route Configuration > Static Route by
clicking it; click the icon behind the node and select Insert Instance. Configure the
static route according the data listed in the following table.
Priority 5 5
Configuration Objects
Active and standby routes need to be configured for the primary and secondary RSGs on the
bearer network
Configuration Roadmap
If the active and standby interfaces have been planned and the RNC supports the dual-receiving
function of these interfaces, you can configure active and standby routes to ensure that the
primary/secondary RSG relationship is consistent with that on the RNC side. This guarantees
millisecond-level fault detection and protection when the primary RSG or the AC link on the
primary RSG is not functioning properly. The RNC uses the IP address of a logical interface as
the target IP address.
l Configure private IGP for subinterfaces between the RSGs to determine the primary/
secondary RSG relationship. IS-IS is used as an example.
l Configure static routes from the primary and secondary RSGs to a logical interface on the
RNC, and import the routes to IS-IS.
l Advertise private IS-IS and static routes to BGP.
NOTE
Unlike VRRP configuration, when you configure active and standby routes, VPN instances use physical
interfaces rather than VLANIF interfaces.
Operation Procedure
Configure private network IS-IS:
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. In the Set Filter Criteria dialog box, click Filter.
3. Select a service to be configured, and click Modify. The Modify L3VPN Service window
is displayed.
4. Select primary and secondary RSGs from the node list, and click Details in the lower left
area. Then VRF Configuration is displayed in the lower right area.
5. On the VRF Configuration tab, expand Route Configuration > ISIS by clicking it; click
the icon behind the ISIS node and select Insert Instance. Then expand the newly-inserted
node and modify its configuration according to the data plan.
Instance ID 2 2
6. On the VRF Configuration tab, choose Route Configuration > ISIS > ISIS Instance >
Route Import > External Route Import for the newly-inserted route instance, and modify
related parameters according to the data plan.
NOTE
To import multiple routes, click the icon behind External Route Import and select Insert Instance.
7. On the VRF Configuration tab, choose Route Configuration > ISIS > ISIS Instance >
Protocol Interface > Protocol Interface > Interface Name for the newly-inserted route
instance, and modify related parameters according to the data plan.
On primary and secondary RSGs, configure a static route destined to the RNC.
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. In the Set Filter Criteria dialog box, click Filter.
3. Select the service to be configured and click Modify. The Modify L3VPN Service window
is displayed.
4. Click Details and then the VRF Configuration tab.
5. Choose Route Configuration > Static Route > Static Route Object from the service tree.
6. Configure a static route according to the data plan.
NOTE
If multiple static routes exist, click the icon next to Static Route and select Insert Instance.
Priority 5 50
Instance ID 2 2
NOTE
You can also click next to the Route Import parameter to add a route import instance.
Level-2 Flash Select this parameter. The Select this parameter. The default
Flood default value is used. value is used.
Follow-up Procedure
When configuring active and standby routes, configure static routes on the RNC. Ensure that
the routes are destined to the primary and secondary RSGs.
Verify Configurations
This topic describes how to check whether configurations are correct.
VRF Ping
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Select the desired Layer 3 Virtual Private Network (L3VPN) service and click the Service
Link tab.
3. Right-click on the tab and choose Fast Diagnose from the shortcut menu.
4. In the VRF Ping dialog box, click Run.
5. The result is Success.
NOTE
For a peer relationship between ASGs and RSGs, configure it between the primary ASG and primary
RSG, or between the secondary ASG and secondary RSG with a priority. The ping operation will be
performed between each pair of peers. If the test result is successful for the priority peer relationship
but failed for non-priority peer relationship, the test is successful. If a peer relationship is configured
between the primary ASG and secondary RSG, ping packets are transmitted from the primary ASG
to the secondary RSG but returned from the secondary RSG to the secondary ASG, resulting in a
ping failure.
VRF Traceroute
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Right-click a Layer 3 virtual private network (L3VPN) service to be configured and choose
Test and Check from the shortcut menu. The Test and Check window is displayed.
3. Click the Diagnosis tab and select VRF Traceroute.
4. Click OK.
5. After test is complete, Result is Operation Succeeded.
Configuration Process
This topic describes the process of deploying PWE3 services and related protection protocols.
Multihop PWE3s are used to carry TDM services between the cell site gateway (CSG) and radio
service gateways (RSGs). Configuration processes are described by allowing for two live-
network scenarios: building a new network and adding a base station.
NOTE
In the network topology, ASGs 3 and 4 respectively function as primary and secondary ASGs, and RSGs 5 and
6 respectively function as primary and secondary RSGs.
Configure BFD for PW on the primary and backup PWs between the CSG and RSGs to
accelerate PW fault detection.
Data Planning
You must plan data as needed before deploying Pseudo Wire Emulation Edge-to-Edge (PWE3)
services and relevant protection protocols.
Table 4-34 TDM service interface planning for the RNC side
No. 1 N/A
Table 4-35 TDM service interface planning for the base station side
Configuration Object
Configure management PWs between primary and secondary RSGs.
Data Plan
Parameter Primary RSG (RSG5) Secondary RSG (RSG6)
Remote BFD The remote BFD ID must be The remote BFD ID must be
ID consistent with the local BFD ID of consistent with the local BFD ID of
the peer NE. the peer NE.
BFD PW1: Cpos port (for TDM services) PW1: Cpos board (for TDM
detection or ATM port (for ATM services) services) or ATM board (for ATM
PW2: Cpos board (for TDM services)
services) or ATM board (for ATM PW2: Cpos port (for TDM services)
services) or ATM port (for ATM services)
NOTE
One side of the BFD detection object of
primary and secondary RSGs is the AC
interface of the management PW, and
the other side is the board where the
management PW resides. RSG_to_ac:
Indicates the BFD session that detects
the AC interface where the management
PW resides. RSG_to_aps: Indicates the
BFD session that detects the board
where the management PW resides.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set Service Type to Management PW and set other parameters as planned.
On the Service Topology tab, right-click and select Create LDP Remote Peer to create an LDP
remote peer quickly.
Step 9 The Operation Result prompt is displayed. Click Browse Trail to view the configuration
results. If the PWE3 service is successfully configured, Running Status is Up.
Step 10 Right-click the PWE3 service in the service list, and choose Configure BFD from the shortcut
menu. The BFD Session Configuration Management dialog box is displayed.
Step 11 Click Create. The Batch Configure BFD Session dialog box is displayed.
Step 12 Click Configure. In the dialog box that is displayed, set BFD parameters for each NE and click
OK after parameters are set. Set key parameters according to the following requirements, and
set the other parameters as required or use default values.
BFD Name Set the BFD name according to the data plan. If you do not set it, the
system automatically allocates one.
Detection Object Click Configure next to Detection Object. In the dialog box that is
displayed,
l For the primary RSG: select Monitoring Interface, click ..., and
select the Cpos port (for TDM services) or ATM port (for ATM
services).
l For the secondary RSG: select Interface Card Index and select the
Cpos board (for TDM services) or ATM board (for ATM services).
Local BFD ID The local BFD ID must be consistent with the remote BFD ID of the
peer NE.
Remote BFD ID The remote BFD ID must be consistent with the local BFD ID of the
peer NE.
Min.Sending 100
Interval
Min.Receiving 100
Interval
Step 14 Repeat steps 1-13 to create a PW between primary and secondary ASGs and bind a BFD session
to the PW according to the data plan.
----End
Configuring E-APS
When APS protection needs to be between the active and standby CSG->RSG PWs or between
RSG nodes, you can configure E-APS on the service interface of primary and secondary RSGs
to implement APS switching between RSGs in case of emergency. For E-APS between RSG
nodes, you can choose either 1+1 or 1:1 protection.
Configuration Object
l For APS protection between the active and standby CSG->RSG PWs, configure primary
and secondary RSGs as the left and right nodes of E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 2 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 4 In the Create E-APS dialog box, set the related parameters.
NOTE
l E-APS 1+1 has four types: single-ended non-revertive, single-ended revertive, dual-ended non-revertive,
and dual-ended revertive. Single-ended non-revertive E-APS 1+1 is recommended.
l E-APS 1:1 has two types: dual-ended non-revertive and dual-ended revertive. Dual-ended revertive E-APS
1:1 is recommended.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as the left node and RSG6 (secondary RSG)
as the right node.
APS
APS Group ID Sets this parameter as planned. The IDs for the local and peer NEs must
be the same.
Local IP Specifies the IP address of the primary or secondary RSG as the local
IP address. The IP address of the RSG loopback interface is generally
used. The local IP address of the left node and the peer IP address of
the right node must be consistent.
Peer IP The local IP address of the local NE must be the same as the peer IP
address of the peer NE.
----End
Configuration Object
The Cpos interface must be added to the Cpos-Trunk interface because the Cpos interface is
used for configuring E-APS that implements link protection between the RSG and the RNC side.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Cpos-Trunk Interface.
Step 4 In the Create Cpos-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. on this tab page.
2. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
interfaces to be added from the Available Interface list on the left and click .
All selected interfaces are added to the Selected Interface list. Click OK.
NOTICE
l Before configuring the Cpos-Trunk interface, make sure that E-APS has been configured.
l The "DS1 list" and the Cpos-Trunk interface cannot be configured at the same time. It can
only be configured in the Cpos-Trunk interface that already exists.
Step 5 Click OK. The Create Cpos-Trunk Interface dialog box is closed.
Step 6 Configure Cpos-Trunk interfaces on the secondary RSG in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
In Physical Topology in the upper-right part, right-click the primary ASG, and choose Set As
Switching Node > Protection from the shortcut menu.
Step 10 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This section describes the process of configuring single-homed MS-PW TDM services and
protection.
As shown in the following figure, MS-PWs are established between the cell site gateway (CSG)
and radio service gateway (RSG).
The following table shows the process of configuring single-homed MS-PW services.
Deleting the Default Timeslot on a Cpos Deleting the Default Timeslot on a Cpos
Interface Interface
Verifying Configurations
NOTICE
If the hot backup or APS protection is deployed for tunnels carrying ATM or TDM services,
ensure that the detection period of BFD for PW is longer than the latency of LSP or APS
switchover. This prevents repeated switchover.
Data Plan
To deploy single-homed MS-PW TDM services and protection, plan the following data.
Table 4-39 TDM service interface planning for the RNC side
No. 1 N/A
Table 4-40 TDM service interface planning for the base station side
Configuration Object
l Select the primary RSG as both the left and right NEs for E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as both the left and right nodes.
APS
Parameter Settings
APS Group ID Sets the APS group ID according to the data plan. The left and right
nodes have the same group ID.
Step 5 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 6 (Optional) Set the RSG ATM port (for the ATM service) connected to the RNC side to the UP
state when receiving optical signals. When the working mode of the protection group is 1+1
unidirectional switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Object
Configure the RSG.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Cpos-Trunk Interface.
Step 4 In the Create Cpos-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. on this tab page.
2. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
interfaces to be added from the Available Interface list on the left and click .
All selected interfaces are added to the Selected Interface list. Click OK.
NOTICE
l Before configuring the Cpos-Trunk interface, make sure that E-APS has been configured.
l The "DS1 list" and the Cpos-Trunk interface cannot be configured at the same time. It can
only be configured in the Cpos-Trunk interface that already exists.
Step 5 Click OK. The Create Cpos-Trunk Interface dialog box is closed.
Step 6 Configure Cpos-Trunk interfaces on the secondary RSG in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
Step 7 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 9 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This topic describes the process of deploying PWE3 services and related protection protocols.
In the mixed VPN solution, the multihop PWE3 is used to carry asynchronous transfer mode
(ATM) services between the cell site gateway (CSG) and radio service gateways (RSGs).
Configuration processes are described by allowing for two live-network scenarios: building a
new network and adding a base station.
NOTE
In the network topology, ASGs 3 and 4 respectively function as primary and secondary ASGs, and RSGs 5 and
6 respectively function as primary and secondary RSGs.
Data Plan
To deploy PWE3 services and related protection protocols, plan the following data.
Channel Set ID 1 -
Table 4-46 ATM interface planning for the base station side
Configuration Object
Configure management PWs between primary and secondary RSGs.
Data Plan
Parameter Primary RSG (RSG5) Secondary RSG (RSG6)
Remote BFD The remote BFD ID must be The remote BFD ID must be
ID consistent with the local BFD ID of consistent with the local BFD ID of
the peer NE. the peer NE.
BFD PW1: Cpos port (for TDM services) PW1: Cpos board (for TDM
detection or ATM port (for ATM services) services) or ATM board (for ATM
PW2: Cpos board (for TDM services)
services) or ATM board (for ATM PW2: Cpos port (for TDM services)
services) or ATM port (for ATM services)
NOTE
One side of the BFD detection object of
primary and secondary RSGs is the AC
interface of the management PW, and
the other side is the board where the
management PW resides. RSG_to_ac:
Indicates the BFD session that detects
the AC interface where the management
PW resides. RSG_to_aps: Indicates the
BFD session that detects the board
where the management PW resides.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set Service Type to Management PW and set other parameters as planned.
Step 9 The Operation Result prompt is displayed. Click Browse Trail to view the configuration
results. If the PWE3 service is successfully configured, Running Status is Up.
Step 10 Right-click the PWE3 service in the service list, and choose Configure BFD from the shortcut
menu. The BFD Session Configuration Management dialog box is displayed.
Step 11 Click Create. The Batch Configure BFD Session dialog box is displayed.
Step 12 Click Configure. In the dialog box that is displayed, set BFD parameters for each NE and click
OK after parameters are set. Set key parameters according to the following requirements, and
set the other parameters as required or use default values.
BFD Name Set the BFD name according to the data plan. If you do not set it, the
system automatically allocates one.
Detection Object Click Configure next to Detection Object. In the dialog box that is
displayed,
l For the primary RSG: select Monitoring Interface, click ..., and
select the Cpos port (for TDM services) or ATM port (for ATM
services).
l For the secondary RSG: select Interface Card Index and select the
Cpos board (for TDM services) or ATM board (for ATM services).
Local BFD ID The local BFD ID must be consistent with the remote BFD ID of the
peer NE.
Remote BFD ID The remote BFD ID must be consistent with the local BFD ID of the
peer NE.
Min.Sending 100
Interval
Min.Receiving 100
Interval
Step 14 Repeat steps 1-13 to create a PW between primary and secondary ASGs and bind a BFD session
to the PW according to the data plan.
----End
Configuring E-APS
When APS protection needs to be between the active and standby CSG->RSG PWs or between
RSG nodes, you can configure E-APS on the service interface of primary and secondary RSGs
to implement APS switching between RSGs in case of emergency. For E-APS between RSG
nodes, you can choose either 1+1 or 1:1 protection.
Configuration Object
l For APS protection between the active and standby CSG->RSG PWs, configure primary
and secondary RSGs as the left and right nodes of E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
NOTE
l E-APS 1+1 has four types: single-ended non-revertive, single-ended revertive, dual-ended non-revertive,
and dual-ended revertive. Single-ended non-revertive E-APS 1+1 is recommended.
l E-APS 1:1 has two types: dual-ended non-revertive and dual-ended revertive. Dual-ended revertive E-APS
1:1 is recommended.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as the left node and RSG6 (secondary RSG)
as the right node.
APS
APS Group ID Sets this parameter as planned. The IDs for the local and peer NEs must
be the same.
NOTE
APS Group ID for an ATM interface that has been added to the ATM-Trunk
cannot be set or modified. To set or modify APS Group ID, remove the ATM
interface from the ATM-Trunk.
Local IP Specifies the IP address of the primary or secondary RSG as the local
IP address. The IP address of the RSG loopback interface is generally
used. The local IP address of the left node and the peer IP address of
the right node must be consistent.
Peer IP The local IP address of the local NE must be the same as the peer IP
address of the peer NE.
Parameter Settings
Step 5 (Optional) Set the RSG ATM port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command to enter the system view.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Objects
The ATM interfaces that are used for configuring E-APS need to be added to Atm-Trunk
interfaces.
ATM service interfaces need to be configured on the primary and secondary RSGs.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Atm-Trunk Interface.
Step 4 In the Create Atm-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. according to the data plan.
2. (Optional) Click the ATM Feature tab and select ATM Cell Transfer. To use the ATM
cell transfer mode, select ATM Cell Transfer; to use a non-transfer mode, deselect it. (The
ATM cell transfer mode requires support of ATM subboards.)
3. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
the desired interface from the Available Interface list on the left and click . The
selected interface is added to the Selected Interface list. Then click OK.
4. Click OK. The Create Atm-Trunk Interface dialog box is closed.
5. On the Interface Information tab page, select the configured ATM-Trunk interface, right-
click, and choose Synchronize from the shortcut menu. In the lower part of the window,
the value of Operating Status is Up.
Step 5 Set the working mode of ATM subboards to ATM cell transfer mode.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the set service-mode slot slotid cell-concatenation-mode command. slotid is the ID
of the slot where the ATM subboard resides.
5. Close the CLI window.
----End
Configuration Objects
ATM service interfaces need to be configured for all CSGs.
Procedure
Step 1 Configure an E1 interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose Interface Management > Interface Information from the service tree.
3. Select the desired E1 interface, such as E1 0/2/1, and click Configure.
4. In the Configure E1 Interface dialog box, click the Physical Feature tab.
5. In the Timeslot Configuration area, click Add.
6. In the Add Timeslot Binding dialog box, set No. and Timeslot Sequence according to the
planning.
7. Click OK. The Add Timeslot Binding dialog box is closed.
8. Click OK. The Configure E1 Interface dialog box is displayed. After you click Query,
serial interfaces named in the format of "E1 interface number + sequence number", such
as Serial 0/2/1:1, are displayed on the Interface Information tab page.
9. Configure other E1 interfaces that need to be bound to an Inverse Multiplexing Over ATM
(IMA) group in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes of PWE3 services. Set a PWE3 service profile that already exists on the
Creating a PWE3 Template as a service profile.
In Physical Topology in the upper-right part, right-click the primary ASG CX600–CC-001, and
choose Set As Switching Node > Working from the shortcut menu.
In Physical Topology in the upper-right part, right-click the secondary ASG CX600–DD-001,
and choose Set As Switching Node > Protection from the shortcut menu.
Step 11 (Optional) Configure a PW template. This step is required only when the ATM subboard does
not support cascading.
1. In the left-hand pane, click Detail.
2. In the details area, click the Advanced PW Attribute tab.
3. Respectively click the cells under Source PW Template and Sink PW Template and click
the "..." button that is displayed. Then, select the PW template that has been created in
Configuring a PW Template for ATM Services in the dialog box that is displayed.
4. Configure the source and sink templates for other PWs in the same manner.
Step 12 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This section describes the process of configuring single-homed MS-PW ATM services and
protection.
As shown in the following figure, MS-PWs are established between the cell site gateway (CSG)
and radio service gateway (RSG).
4. Configure MS-PW services on the CSG and RSG, and PW exchange on ASGs.
5. Configure static BFD for PW between the CSG and RSG to accelerate the switchover
between the primary and backup PWs in case of faults.
NOTICE
If the hot backup or APS protection is deployed for tunnels carrying ATM or TDM services,
ensure that the detection period of BFD for PW is longer than the latency of LSP or APS
switchover. This prevents repeated switchover.
Data Plan
To deploy single-homed MS-PW ATM services and protection, plan the following data.
Channel Set ID 1 —
Table 4-52 ATM interface planning for the base station side
Min. Receiving 50 -
Interval(ms)
Min. Sending 50 -
Interval(ms)
Configuration Object
l Select the primary RSG as both the left and right NEs for E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as both the left and right nodes.
APS
APS Group ID Sets the APS group ID according to the data plan. The left and right
nodes have the same group ID.
Step 5 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 6 (Optional) Set the RSG ATM port (for the ATM service) connected to the RNC side to the UP
state when receiving optical signals. When the working mode of the protection group is 1+1
unidirectional switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Objects
ATM service interfaces need to be configured for all CSGs.
Procedure
Step 1 Configure an E1 interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose Interface Management > Interface Information from the service tree.
3. Select the desired E1 interface, such as E1 0/2/1, and click Configure.
4. In the Configure E1 Interface dialog box, click the Physical Feature tab.
5. In the Timeslot Configuration area, click Add.
6. In the Add Timeslot Binding dialog box, set No. and Timeslot Sequence according to the
planning.
7. Click OK. The Add Timeslot Binding dialog box is closed.
8. Click OK. The Configure E1 Interface dialog box is displayed. After you click Query,
serial interfaces named in the format of "E1 interface number + sequence number", such
as Serial 0/2/1:1, are displayed on the Interface Information tab page.
9. Configure other E1 interfaces that need to be bound to an Inverse Multiplexing Over ATM
(IMA) group in the same manner.
----End
Configuration Object
Configure the RSG.
Procedure
l If the NodeB supports APS protection, you are advised to use the ATM-Trunk interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut
menu.
2. Choose Interface Management > Interface Information from the service tree.
3. On the Interface Information tab page, click Create and choose Create Main
Interface > Atm-Trunk Interface.
4. In the Create Atm-Trunk Interface dialog box, set the relevant parameters.
a. Click the General tab and set Interface No. according to the planning.
b. (Optional) Click the ATM Feature tab and select ATM Cell Transfer. To use
the ATM cell transfer mode, select ATM Cell Transfer; to use a non-transfer
mode, deselect it. (The ATM cell transfer mode requires support of ATM
subboards.)
c. Click the Member Interface tab and click Add. In the dialog box that is
displayed, select the desired interface from the Available Interface list on the
left and click . The selected interface is added to the Selected
Interface list. Then click OK.
d. Click OK. The Create Atm-Trunk Interface dialog box is closed.
e. On the Interface Information tab page, select the configured ATM-Trunk
interface, right-click, and choose Synchronize from the shortcut menu. In the
lower part of the window, the value of Operating Status is Up.
l If the base station does not support APS protection, the ATM interface is recommended.
In this situation, the ATM interface does not need to be configured.
l Set the working mode of ATM subboards to ATM cell transfer mode.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the set service-mode slot slotid cell-concatenation-mode command. slotid is
the ID of the slot where the ATM subboard resides.
5. Close the CLI window.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
Step 7 (Optional) Set the PW ID according to the data plan or enable auto-assignment.
Step 9 (Optional) Configure a PW template. This step is required when the ATM subboard does not
cascading.
1. In the left-hand pane, click Detail.
3. Respectively click the cells under Source PW Template and Sink PW Template and click
the "..." button that is displayed. Then, select the PW template that has been created in
Configuring a PW Template for ATM Services in the dialog box that is displayed.
4. Configure the source and sink templates for other PWs in the same manner.
Step 10 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 11 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This topic describes the process for configuring SD bit error detection.
l Configure the MPLS label distribution mode to non-null using the U2000 IP plug-and-play
management function.
l Configure bidirectional LSPs on the U2000.
l Configure bit error detection thresholds for ports on the U2000.
l For the MPLS L2VPN service with the PW redundancy protection, configure SD bit error
detection for AC interfaces and intermediate nodes (multi-segment PWs) on the U2000 to
trigger protection switching.
Configuration Object
Configure bit error detection thresholds for ports on links to be tested.
NOTE
You can use a template of the U2000 IP plug-and-play management function to bulk configure the thresholds.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 5 In the dialog box that is displayed, click the Monitor Trap Threshold tab, select the CRC
Packet error ratio check box, and set Alarm threshold Coefficient, Resume threshold
Coefficient, Alarm threshold exponent, and Resume threshold exponent according to the
data plan.
Step 6 Select the Trigger LSP check box.
----End
Configuration Object
Configure SD bit error detection on the source and sink nodes of primary and backup tunnels
on the bearer network.
Procedure
Step 1 Choose Service > Tunnel > Manage Tunnel from the main menu.
Step 2 In the Set Filter Criteria dialog box, set filter criteria and click Filter. All services meeting the
filter criteria are displayed.
Step 3 In the service list, select the tunnel for which to configure bit error detection. In the lower pane,
click the Bit Error Detection tab.
Step 4 Set Bit Error Detection Mode to Bidirectional.
Step 5 Click Select. In the Select Tunnel dialog box, select the mapping backward tunnel, and click
OK.
----End
Configuration Object
Configure SD bit error detection on primary and backup PWs for low-speed services.
Procedure
Step 1 Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
Step 2 In the Set Filter Criteria dialog box, set filter criteria and click Filter. All services meeting the
filter criteria are displayed.
Step 3 In the service list, right-click the desired PWE3 service and choose Bit Error Detect >
Enable from the shortcut menu.
----End
Configuration Roadmap
Different clock deployment solutions are available for different synchronization requirements.
Multiple technologies can be used to transparently transmit clock signals. The recommended
solution is: using 1588v2 to achieve time synchronization, using synchronous Ethernet to
achieve frequency synchronization, and selecting sources according to Synchronization Status
Message (SSM).
l To achieve frequency synchronization using synchronous Ethernet, see Selecting the
Clock Source and Configuring Synchronous Ethernet Clock.
l To achieve time synchronization using 1588v2, see Selecting the Clock Source,
Configuring Synchronous Ethernet Clock, and Configuring the 1588v2 Clock.
NOTE
In this topology, ASG3 acts as the primary ASG, ASG4 as the secondary ASG, RSG5 as the primary RSG, and
RSG6 as the secondary RSG.
For the output clock interface, do not set a priority but enable clock synchronization. For the input clock interface,
set a priority according to the clock plan and enable clock synchronization.
In this scheme, the synchronous Ethernet clock is used to implement frequency synchronization
and the 1588v2 clock is used to implement time synchronization.
l Synchronous Ethernet clock
A clock priority must be configured for every NE interface to prevent clock loops.
l 1588v2 clock
All the NEs reside in a 1588v2 clock domain and the primary and secondary RSGs have
external clock sources. The clock priorities for the primary and secondary RSGs must be
higher than those for other NEs and the clock priority for the primary RSG must be higher
than that for the secondary RSG. The clock tracing relationship in the clock domain is
determined by the Best Master Clock (BMC) algorithm.
Data Planning
Plan different parameter values based on the different requirements of frequency
synchronization and time synchronization.
l In this document, the RSGs are CX600-X8s and each RSG has three clock ports: bits0,
bits1, and bits2. The three clock ports can be used for both frequency synchronization and
phase synchronization. In this example, port bits2 is used to receive frequency
synchronization signals and port bits0 is used to receive time synchronization signals.
l For synchronous Ethernet, source selection control is implemented by enabling SSM and
configuring clock signal priorities in the local priority list.
NOTE
For clock synchronization of synchronous Ethernet, the source selection sequence is: SSM clock quality
> local priority setting > clock source type.
l The priority list of SSM clock qualities is: PRC > SSUA > SSUB > SEC > DNU. Source selection
does not involve the sources not configured with priorities or with the quality of DNU.
l In local settings, the priority value can be set to 1 to 255. Smaller numbers indicate higher priorities.
Source selection does not involve the sources not configured with priorities.
l The priority of a BITS clock source is higher than a clock source connected to a service port.
l The dynamic BMC source selection algorithm is run for 1588v2.
NOTE
When the BMC algorithm is used by a 1588v2-enabled device for source selection, priority1 of each
candidate time source is compared first, then the clock-class, clock-accuracy, and priority2. If priority1
of candidate time sources is the same, the clock-class is compared, and so on. The time source with the
highest priority is selected as the master clock. In this example, it is recommended that priority2 be used
for clock source selection. Retain the default settings for priority1, clock-class, and clock-accuracy.
RS Clock input type 2mhz The value can be 2mhz or 2mbps. The
G5 default value is 2mbps.
GE1/0/0 -
RS Clock input type 2mhz The value can be 2mhz or 2mbps. The
G6 default value is 2mbps.
GE1/0/0 -
GE0/2/1 20
6
Importing Links
This topic describes how to import links to generate a clock topology before clock deployment.
Procedure
Step 1 Choose Inventory > Fiber/Cable/Microwave Link > Fiber/Cable/Microwave Link
Management from the main menu. The Fiber/Cable/Microwave Link Management window
is displayed.
Step 2 Right-click in a blank area and choose Import Link from the shortcut menu. The Import
Link dialog box is displayed.
----End
Configuration Object
Perform configurations on the primary and secondary radio service gateways (RSGs) on the
bearer network.
Procedure
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose System Management > Clock Management > Physical Clock Management
from the navigation tree. Then, click the Other Clock Source subtab on the Clock
Source tab.
3. Select the bits0 clock source, and set parameters on the General tab as follows:
l Select the Enable Clock check box.
l Set SSM Source Select Mode to Manual.
l Set Input SSM Class to Prc.
l Select the System Priority check box.
l Set System Priority to 10 (10 for the primary RSG and 20 for the secondary RSG)
l Set Clock Type to 2Mhz.
l Retain the default values of other parameters.
NOTE
In this example, external BITS signals are 2 MHz signals. If BITS signals are 2 Mbps signals, you do
not need to set the SSM Source Select Mode and Input SSM Class parameters, but need to set Clock
Type to 2Mbit/s.
4. Select the bits1 clock source, and set parameters on the General tab as follows:
l Set Clock Type to 1pps.
l Set Direction to In.
l Retain the default values of other parameters.
5. On the Physical Clock Management tab, click the General subtab and set TOD
Format to Ubx.
6. (Optional) On the Clock Source tab, click the Other Clock Source subtab, select the
ptp clock source, and set parameters in the lower pane as follows:
NOTE
This step is mandatory when IEEE 1588v2 is deployed.
7. Click Apply.
NOTE
A clock source can be used only when it is in the normal state.
Configuration Objects
Synchronous Ethernet clock needs to be configured for all NEs on the bearer network.
Procedure
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose System Management > Clock Management > Physical Clock Management
from the service tree. Then click the General tab and set relevant clock parameters.
l Select Enable Ethernet Synchronization.
l Select SSM Control.
l Use the default values for other parameters.
3. Click the Clock Source tab and then the Port Clock tab. Click Add. The Select
Interface dialog box is displayed.
4. Select the interface that connects RSG5 to RSG6 and click OK.
5. Select this interface, set the relevant parameters on the General tab page, and click Apply
NOTE
For the output clock interface, do not set a priority but enable clock synchronization. For the input
clock interface, set a priority according to the clock plan and enable clock synchronization.
For example, GE interface 1/1/2 is an output clock interface; therefore, enable clock
synchronization for it; GE interface 2/1/0 is an input clock interface and the interface
priority is 1; therefore, set the priority to 1 and enable clock synchronization for it.
6. In the dialog box displayed indicating that the operation is successful, click OK.
7. Set clock information for the rest of the NEs according to the planning.
NOTE
Clock synchronization must be enabled for the interface between the CSG and the base station.
Configuration Objects
The 1588v2 clock needs to be configured for all NEs on the bearer network.
Procedure
1. Enable the Precision Time Protocol (PTP) clock.
a. In the NE Explorer, choose System Management > Clock Management > PTP
Clock Management from the service tree. The PTP Clock Management tab page is
displayed.
b. Click the General tab and set the relevant parameters. Then click Apply.
l Select Enable PTP.
l Set Clock Domain according to the planning.
l Set Clock Type according to the planning.
l Select Enable Ring Fiber Asymmetry Measure.
c. On the Port Clock Source tab page, select this interface, set the relevant parameters
on the Basic Information tab page, and click Apply.
l Select Enable PTP.
l Set Delay Mechanism to Pdelay.
l Set Clock Step to One-step.
4. Configure the 1588v2 clock for the rest of the NEs in the same manner.
Verifying Configurations
This topic explains how to verify configurations.
Procedure
Step 1 Select Clock View from the Current View drop-down list in the upper left part of the Main
Topology. Then select an IPRAN subnet from the navigation tree. The clock status of each NE
is displayed.
Step 2 Right-click in the Main Topology and choose Search Clock Link from the shortcut menu. The
Search Clock Link dialog box is displayed. Set the relevant parameters and click OK.
l Select 1588v2 and Synchronous ETH in the Clock Type area.
l Click Search from NE in the Search Mode area.
l Select IPRAN in the NE Search area.
Step 3 In the dialog box that is displayed, click Close. The clock tracing relationships between NEs are
displayed in the clock view. Check whether the relationships are the same as those planned. If
some relationships are different from those planned, check whether the clock parameters are set
according to the planning.
Step 4 Click Legend&Filter&Attribute and select the desired clock type on the Filter tab page.
3. Select a clock source and click Delete. In the dialog box that is displayed, click OK.
You can delete all port clock sources of a device by selecting all of them and clicking
Delete.
4. Click the General tab and select Enable PTP Clock.
5. On the Physical Clock Management tab, select Clock Source > Port Clock Source.
6. Select a clock source and click Delete. In the dialog box that is displayed, click OK.
You can delete all port clock sources of a device by selecting all of them and clicking
Delete.
7. Click the General tab and deselect Enable Ethernet Synchronization.
8. Click Apply.
9. Click Synchronize.
----End
Configuration Object
This solution uses simple traffic classification to deploy QoS and set CAR parameters for the
network interface of CSGs and RSGs.
Configuration roadmap:
l Create Diffserv profile example used to configure the service interface and network
interface of CSGs, ASGs, and RSGs.
NOTE
If priority mapping rules configured in the default profile are appropriate, use the default profile.
l Apply the Diffserv profile to the interfaces.
l Create an HQoS profile used to configure CAR of the network interface of CSGs and RSGs.
Apply the profile to the interface.
Data Plan
AF2 WFQ 10
AF3 WFQ 15
AF4 WFQ 15
BE WFQ 10
AF2 WFQ 10
AF3 WFQ 15
AF4 WFQ 15
BE WFQ 10
Procedure
Step 1 Configure differentiated services for the outbound direction of the CSG user side.
1. In the NE Explorer, right-click the CSG, choose Service Tree > VPN Management >
L3VPN Management > VRF Management, and click Query.
2. Select the VRF and click Configure. The Configure VRF window is displayed.
3. Click Advanced. The Configure Advanced Attributes of VRF window is displayed.
4. Set Down DiffServ Mode to Pipe and click OK.
5. Click Apply.
1. Choose Configuration > IP QoS Profile > DS Domain Profile from the main menu.
2. On the DS Domain Profile tab page, right-click in the blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create DS Domain Profile dialog box, set Name to example. Then configure the
mapping between the Differentiated Services Code Point (DSCP) and Class of Service
(CoS) and set parameters in the Inbound Parameters area. Use the default values for the
parameters in the Outbound Parameters area.
4. Click OK.
Step 4 Disable PHB for the service interface of ASGs and RSGs.
1. In the NE Explorer, right-click the CSG, choose Service Tree > QoS Management >
Configure Interface QoS, and click Query.
2. Select the service interface and click the Other tab.
3. Select Disable PHB.
4. Click Apply.
1. Choose Configuration > IP QoS Profile > HQoS Profile from the main menu.
2. On the HQoS Profile tab page, right-click in the blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create HQoS Profile dialog box, set Name to CSG_UNI and click Add.
4. In the User Queue dialog box, click … next to the Flow Queue Policy text box.
5. In the Select Flow Queue Profile dialog box, right-click in the blank area and choose Add
Global Profile from the shortcut menu.
6. In the Create Flow Queue Profile dialog box, set Name to CSG_UNI. Then set the
relevant parameters according to the planning. Click OK.
7. In the Add User Queue dialog box, set CIR to 4000, PIR to 4000, and Direction to
Outbound. Then click OK.
----End
Configuration Roadmap
Three types of ATM services need to be configured and they are provided by the three user-side
IMA subinterfaces of the CSG and transmitted to the three ATM trunk subinterfaces of the RNC.
On the three IMA subinterfaces of the CSG, three types of ATM services are configured: cbr,
vbrNrt, and vbrRt.
On the three IMA trunk subinterfaces of the RSG, three types of ATM services are configured:
cbr, vbrNrt, and vbrRt.
Data Planning
Procedure
Step 1 Configure an ATM policy profile.
1. Choose Configuration > IP QoS Profile > ATM Policy Profile from the main menu.
2. On the ATM Policy Profile window, right-click a blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create ATM Policy Profile dialog box, set desired parameters according to the data
plan. Click OK.
4. On the ATM Policy Profile window, right-click a profile and choose Download to NE
from the shortcut menu.
5. In the dialog box that is displayed, select the desired NE and click Next. After download
is complete, click Close.
Step 2 Choose Service > PWE3 Service > Manage PWE3 Service from the shortcut menu.
Step 3 In the Set Filter Criteria dialog box, set filter criteria and click Filter. Then all services that
meet the filter criteria are displayed.
Step 4 Select services to be configured from the service list, click the Topology tab, right-click an ATM
interface, and choose Configuration from the shortcut menu.
Step 5 In the Configure ATM Interface dialog box, click the PVC/PVP tab, select PVC, and click
Configure.
Step 6 In the Configure PVC dialog box, click … next to Service Name.
Step 7 In the Select ATM Service dialog box, select the configured ATM policy profile.
Step 11 Configure the other two IMA subinterfaces and the Atm-Trunk interface of the RSG according
to the data plan.
----End
Procedure
l Basic configurations
All basic configurations are applied to NEs using the IP plug-and-play management
function. Basic configurations include basic device configurations, AAA and user
management, loopback interface configuration, network interface configuration, and
SNMP configurations.
l IGP configurations
All IGP configurations are applied to NEs using the IP plug-and-play management function.
IGP configurations include global routing configuration, interface route and IP and routing
policies.
l MPLS configurations
LSP Deployment Mode Data application using the IP Plug and Play
function
Tunnel Policy
----End
Configuration Principle
If IGP routes are deployed and the cost value is configured as planned on a network, route
selection can be controlled. In this case, MPLS LDP LSPs of the host on the network can be
triggered based on the routing table.
Data Planning
This topic provides the data plan for MPLS LDP configuration.
ASG4 4.4.4.4
RSG5 5.5.5.5
RSG6 6.6.6.6
Configuration Object
Configure BFD for LSP on the primary and secondary ASGs and the primary and secondary
RSGs on a bearer network.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 In the Service Tree, choose Reliability > BFD Management > Service Detection
Configuration > LDP LSP Detection Configuration from the main menu.
Step 3 Click Configure. The Set Dynamic BFD Detect LDP LSP Detection dialog box is displayed.
Step 4 Select Enable Dynamic BFD for LDP LSP Detection and Set Dynamic BFD Detect LDP
LSP Trigger Policy, and set Trigger Type to FEC List.
Step 5 Click ... next to FEC List. The Set FEC List dialog box is displayed. Enter the FEC list name,
click New, enter Peer IP Address, and click Apply. The following table lists the data plan for
NE parameters.
----End
Deploying MPLS TE
This topic describes how to deploy Multi-Protocol Label Switching Traffic Engineer (MPLS
TE) to create TE tunnels for carrying services.
Configuration Principle
This topic describes the principle for configuring layered MPLS TE tunnels.
As shown in Figure 4-12, deploy MPLS TE tunnels to carry MPLS VPN for transport wireless
services.
specify paths for deployment. In this solution, configure explicit paths according to the
following rules.
NOTE
In the preceding figure, A to E indicate TE constraint interfaces for TE1 to TE7 respectively.
TE1 A Loose
TE2 B Loose
TE3 C Loose
TE4 B Loose
TE5 D Loose
TE6 D Loose
TE7 E Strict
the secondary LSP. For example, use the strict constraint interface E for the primary
LSP of TE7 in the upstream and downstream directions.
– Configure the hot-standby CR-LSP overlap-path function to maximize protection
for the primary LSP.
– Configure the tunnel re-optimization function. You are advised to set the re-
optimization interval to 3600s.
NOTE
If the secondary LSP of a tunnel is not configured with constraint paths, a best-effort path is not
required for the tunnel. Otherwise, a best-effort must be configured for the tunnel.
l Automatic path selection: Properly plan cost values for links and use the TE CSPF
function to automatically select paths. In this mode, tunnel deployment is simple and
network adjustment is easy. On a network with a clear structure, use automatic path
selection. The configuration principle is as follows:
– TE automatic path selection is implemented based on IGP routes. Therefore,
configure the cost values according to the network plan when configuring IGP. For
details on IGP cost values, see the related IGP configuration topic.
– To ensure that services are transmitted over the best path, configure the tunnel re-
optimization function. You are advised to set the re-optimization interval to 3600s.
– To maximum protection for the working path of tunnels configured with hot-
standby, configure the CR-LSP overlap-path function.
For TE to automatically select proper paths, plan cost values for links. To ensure the
primary TE LSPs select the paths of the rings,the access link between the master and
slave ASGs must have a higher cost value than the maximum metric value of the access
ring. For example, cost values for links a, b, c, and d in the following figure must meet
the following rule: (cost(a) + cost(b) + cost(d)) < cost(c). In addition, set the cost values
for links between the master and slave NPEs based on the following rules: (n - 1) x 10
< cost < n x 10 (for IS-IS); (n - 1) < cost < n (for OSPF); where n is the number of links
on the aggregation ring, excluding the link between RSGs. The figure below shows an
example of cost value plan for this example.
l Create tunnels TE3 and TE4 as the VPN backup tunnels for the VPN working
tunnel TE1 or TE2.
NOTE
When Ethernet and ATM/TDM services share tunnels, the services can also share tunnel policies as
in this example. If Ethernet and ATM/TDM services do not share tunnels, tunnel policies need to be
configured for the services respectively.
6. Create a tunnel policy.
Specify CR-LSP tunnels as the tunnels to be selected first.
Context
You need to create multiple templates based on different requirements for tunnel settings.
NOTE
Path Constraint in the following table applies to the primary tunnel only.
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to RSVP-TE Tunnel and click
Filter.
Step 3 In the Manage Service Template window, click Create > RSVP-TE Tunnel Template.
Step 4 In the Create RSVP-TE Tunnel Template window, set Template Name as planned. The
following table lists the planned template parameters.
TE Information
Trail Information
Reversion Interval(s) 60
BFD Information
NOTE
The check box needs to be selected only when you configure the templates for the primary VPN tunnel on
the access ring or all tunnels on the aggregation ring.
DetectMultiplier 3
MinReceiveSendInterval 50
DetectMultiplier 3
MinReceiveSendInterval 10
Advanced—>Setup Attribute
Advanced—>Reoptimization
Interval(s) 3600
----End
Configuration Object
On the bearer network, configure seven MPLS TE tunnels for service bearer and protection
according to the data plan.
Procedure
Step 1 Create tunnels.
Choose Service > Tunnel > Create Tunnel from the main menu.
Reverse Tunnel When the Create Reverse Tunnel function is enabled, the U2000
Name automatically sets Reverse Tunnel Name to Tunnel Name+_RVS.
NOTE
The Yes check box beside Create Reverse Tunnel is selected by default.
Step 3 Add source and sink NEs according to the data plan.
In Physical Topology, right-click source and sink NEs respectively.
NOTE
If requiring the forward and reverse tunnels to constrain different interfaces, you need to configure
constrained interfaces respectively for both tunnels.
3. In the dialog box that is displayed, select the interface traversed by the primary forward
path and click OK.
NOTE
Click Show all Interface and select an interface from all interfaces on the current NE.
4. In the Route Constraint area, set Restriction Type on the Forward tunnel primary
trail and Reverse tunnel primary trail tabs. Restriction Type is set to Loosely include
by default. However, you need to set it to Strictly include for tunnels between the primary
and secondary RSGs.
Step 6 After the tunnels are created successfully, the Operation Result dialog box is displayed. Click
Browse Trail to view the tunnel configuration results. Running Status is Up, Alarm
Severity is Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
----End
Verifying Configurations
This topic explains how to verify configurations.
LSP Ping
1. Choose Service > Tunnel > Manage Tunnel from the main menu.
2. In the Set Filter Criteria dialog box, set the search criteria and click Filter. The qualified
tunnels are displayed.
3. Select a tunnel. In the tunnel topology displayed in the lower area, right-click the tunnel
and choose Fast Diagnose from the shortcut menu.
4. In the LSP Ping dialog box, click Run.
5. View the test results in the Detail area.
6. Repeat the preceding steps to check whether LSP Ping can be successfully performed for
the rest of the tunnels.
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to L3VPN and click Filter.
Step 3 In the Manage Service Template window, click Create > L3VPN Service Template.
Step 4 In the Create L3VPN Service Template window, set Template Name as planned. The
following table lists the planned template parameters.
Control
General
VRF ID Auto-Assign
Import RT N/A
Export RT N/A
Priority 60
Description N/A
VRRP ID N/A
Lock N/A
----End
Procedure
Step 1 Choose Service > Service Template from the main menu.
Step 2 In the Set Filter Criteria dialog box, set Template Type to PWE3 and click Filter.
Step 3 In the Manage Service Template window, click Create > PWE3 Service Template.
Step 4 In the Create PWE3 Service Template window, set Template Name as planned. The following
table lists the planned template parameters.
General
Remarks N/A
Working PW—>Advanced
Encapsulated Frames 8
Protection PW—>Advanced
Encapsulated Frames 8
SAI
BFD Configuration
Detection Multiple 3
OAM Mapping
Operation Attribute
Deploy Deploy
Enable Enable
General
Remarks N/A
Working PW—>Advanced
Protection PW—>Advanced
SAI
BFD Configuration
Detection Multiple 3
OAM Mapping
Operation Attribute
Deploy Deploy
Enable Enable
----End
Configuration Object
Set Max.ATM Cells on the cell site gateway (CSG) and on the primary and secondary radio
service gateway (RSGs).
Procedure
1. In the Main Topology, right-click the desired NE and choose NE Explorer from the
shortcut menu.
2. Choose VPN Management > PWE3 Management > PW Template Management from
the Service Tree.
3. Click Create. The Create PW Template dialog box is displayed.
4. Set the PW template name according to the data plan.
5. Set Control Word to Yes.
6. Set Max.ATM Cells to 1.
NOTE
When ATM subboards do not support cascading, the maximum number of ATM cells should be set to 1.
7. Click OK.
Configuration Process
In this solution, the PWE3 is used to transmit Ethernet services on an access ring, and the L3VPN
is used to transmit them on an aggregation ring. Aggregation site gateways (ASGs) terminate
PW services and access Ethernet services over the L3VPN. Primary and backup PWs are
deployed on the access ring and L3VPN IGP convergence and FRR are deployed on the
aggregation ring for service protection.
NOTE
In the network topology, ASGs 3 and 4 respectively function as primary and secondary ASGs, and RSGs 5 and
6 respectively function as primary and secondary radio service gateways (RSGs).
On an E2E IPRAN network, configure the Ethernet services and protection as follows:
1. Establish BGP peer relationships to advertise L3VPN routes on the aggregation network.
l Establish BGP peer relationships between the primary ASG and the primary and
secondary RSGs.
l Establish BGP peer relationships between the secondary ASG and the primary and
secondary RSGs.
2. Configure the PW services.
l Specify the PW from the CSG to the primary ASG as the primary PW.
l Specify the PW from the CSG to the secondary ASG as the secondary PW.
3. Configure the L3VPN service and protection.
4. You can configure the VRRP or primary and backup routes to implement RSG dual-homing
protection. It is recommended that you configure the VRRP for this purpose.
l Configure the VRRP on the VLANIF interfaces of the primary and secondary RSGs.
In this case, the radio network controller (RNC) uses only the primary physical interface
to receive packets from RSGs.
l Configure primary and backup static routes. In this case, the RNC uses both the primary
and secondary logical interfaces to receive packets from RSGs.
On a new access ring, configure the Ethernet services and protection as follows:
Data Plan
To deploy a mixed VPN for Ethernet services, plan the following data.
Interface Ethernet0/3/0.2 -
Mask 255.255.255.0 -
Mask 255.255.255.0 -
VE Group 1 - -
ID
VRF ID The value is allocated You can set a value or use the value
automatically. allocated by the NMS.
Delay 300 0
Configuring PWs
This topic describes how to configure primary and backup PWs destined to aggregation site
gateways (ASGs) on the cell site gateway (CSG).
Configuration Object
Configure PWs from the CSG to primary and secondary ASGs.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Select the PWE3 service template created in Creating a PWE3
Template.
3. (Optional) Click Configure. In the Configure Ethernet Interface window, click the
Physical Feature tab, and set the Working Mode and Negotiation Rate for the service
access interface.
NOTE
The CSG and base station must have the same interface settings.
4. Click OK.
5. Click OK.
6. Select the VE interface. Then, click the SAI Configuration tab and create a VE subinterface
by setting its ID and VLAN ID.
7. Click OK.
8. On the Physical Topology tab, right-click the secondary ASG and choose Select
Protection-Sink from the shortcut menu. Then, configure the secondary ASG by referring
to the preceding steps.
3. Click OK.
Step 6 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 8 After the PWE3 service is created successfully, the Operation Result dialog box is displayed.
Click Browse Trail to view the PWE3 configuration results.
Running Status is Up, Alarm Severity is Normal, Deployment Status is Deployed, and
Enabling Status is Enabled.
----End
Configuration Objects
All the main interfaces that connect RSGs or connect the RSGs and the RNC side must be
configured as Layer 2 interfaces.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 4 Select the interface to be configured and click Configure. A dialog box is displayed.
Step 5 If the interface is an Ethernet port, click the Ethernet Feature tab, select Layer 2, and click
OK.
Step 6 If the interface is an Eth-Trunk port, click the Physical Feature tab, select Layer 2, and click
OK.
----End
Configuration Object
Configure the interface connected to the base station on the cell site gateway (CSG) and
interfaces connected to the RNC on the primary and secondary radio service gateways (RSGs).
Procedure
Step 1 In the Main Topology, right-click the desired NE and choose NE Explorer from the shortcut
menu.
Step 2 Choose System Management > DCN Communication Management > DCN Management
from the Service Tree.
Step 3 In the right pane, click the Port Settings tab and click the GE option button.
Step 4 Select the desired port and set Enabling Status to Disabled.
----End
Configuration Object
Configure the L3VPN service on aggregation site gateways (ASGs) and radio service gateways
(RSGs).
3. In the Physical Topology, right-click an ASG and choose Add SPE Node to Service from
the shortcut menu, and right-click an RSG and choose Add NPE Node to Service from
the shortcut menu. After the configuration, the NEs are displayed in Node List in the lower-
left part.
NOTE
7. Configure the parameters for the Layer 3 VE interface on the primary ASG. Perform this
step when an association scheme is used.
a. On the SAI Configuration tab, click the Advanced subtab.
b. Select the Layer 3 VE interface of the primary ASG, set Direct Route
Configuration to Direct Route Track PW Status, Degrade Cost to 500, and
Interface Status Track PW Status to Enable.
8. Configure RNC-side interfaces on the primary and secondary RSGs (with VRRP enabled).
a. On the VRF Configuration tab, choose SAI > Interface.
b. Click the button in the cell at the intersection of the RSG NE column and the Interface
Name row. The Create SAI dialog box is displayed.
c. Choose Create > VLANIF. Then the Add VLAN Interface dialog box is displayed.
d. On the General tab, click ... next to Interface No.. Then the Select VLAN ID dialog
box is displayed.
e. Select an existing VLAN or click Create. In the Create VLAN dialog box, enter the
VLAN ID and click OK to create a VLAN.
f. On the VLAN Member Port tab, click Add. Then the Add Member Port dialog box
is displayed.
g. Select ports from Available Port and click to add ports to the Selected
Port list.
h. In the Selected Port list, set Binding Mode to Passable VLAN for the two ports as
listed in the following table, and click OK.
a. On the VRF Configuration tab, choose Route Configuration > BGP > BGP
Instance > Route Import > Route Import Instance.
b. Set Route Type and Instance ID.
NOTE
To import multiple routes, click the icon next to the Route Import node and choose Insert
Instance.
11. (Optional) Configure the VRRP (required only when the VRRP protection is used).
VR IP 192.168.2.100 192.168.2.100
Delay(s) 300 0
Notification Interval(s) 30 30
Increase Priority By 40 40
e. Click the Track BFD option button and Con. The Configure BFD dialog box is
displayed. Set parameters according to the data plan.
Min.Receiving Interval 50 50
Min.Sending Interval 50 50
f. After the BFD configuration is complete, click OK in the Configure BFD dialog box.
g. In the Configure VRRP dialog box, click OK.
12. In the Create L3VPN Service window, click Apply to apply the L3VPN service.
13. After the L3VPN service is applied successfully, the Operation Result dialog box is
displayed.
14. Click Browse Trail to view the L3VPN configuration results.
Running Status is Up, Alarm Severity is Normal, Deployment Status is Deployed, and
Enabling Status is Enabled.
NOTE
To view the path carrying the L3VPN service, perform the following operations:
In the Manage L3VPN Service window, select the created L3VPN service, and click Refresh on the
Service Link tab to view the path data or click the Topology tab to view the path in the Service
Topology.
NOTICE
If Running Status is not Up, right-click the L3VPN service, choose Refresh Running
Status from the shortcut menu, and view Running Status.
station and 192.168.1.2 indicates the IP address of the base station port connected to
the CSG.
e. Exit the CLI.
f. Configure a static route on the secondary ASG by referring to the preceding steps.
16. (Optional) Modify the L3VPN service.
a. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
b. Right-click the L3VPN service and choose Modify from the shortcut menu. The
Modify L3VPN Service window is displayed.
c. Modify parameters as required and click OK.
d. If you have not selected the VPN Auto FRR check box during the L3VPN service
creation, you can perform only the following operations for the VPN Auto FRR
function to take effect:
a. On the VRF Configuration tab, choose General > Label Distribution Policy
and set Label Distribution Policy to Per VPN.
b. On the VRF Configuration tab, choose General > Routing Policy > Routing
Policy Object > Routing Policy.
c. Double-click in the cell at the intersection of each NE column and the Routing
Policy row, and click .... The Select Routing Policy dialog box is displayed.
d. Click Create. In the Create Policy dialog box, set parameters.
Node ID 10
f. Click Create in the lower pane. In the Create Policy Rule dialog box, set
parameters.
Behavior Apply
Auto Selected
Configuration Object
Configure the primary and secondary RSGs that are located on the bearer network.
Procedure
Step 1 Right-click an NE on the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Ethernet Feature Management VLAN ManagementPort VLAN Management from
the service tree.
Step 5 In the Modify VLAN Attribute of Port dialog box, set Port Link Type to a required value.
----End
Configuration Object
The primary and secondary RSGs.
Configuration Procedure
1. (Optional)Configure BFD for detecting the peer RSG. (This operation is required only if
RSGs have a 10GE link between them.)
a. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
b. In the Set Filter Criteria dialog box, click Filter.
c. Select the desired service, right-click, and choose Configure BFD from the shortcut
menu.
d. In the BFD Session Configuration Management window, click Create.
e. Set BFD detection path to the link between the primary and secondary RSGs.
f. Click Configure on the right of BFD session.
g. Set Bound Service Type to IP Link.
h. Set other parameters according to data plan.
i. Double-click the Detection Object text box, then click Configure that is displayed.
In the dialog box that is displayed, set IP bind type to Default multicast address,
and set the physical interface between RSGs as the outgoing interface according to
data plan.
j. Click OK.
k. Click OK to dismiss the Configure BFD Session dialog box.
l. Click OK and create a BFD session.
2. (Optional)Configure a static route.
NOTE
If the RNC uses a logical address, the static route should destined to the logical address. In addition, the
static route must be referenced by VPN instances.
a. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
b. In the Set Filter Criteria dialog box, click Filter.
c. Select a service to be configured, and click Modify.
d. On the VRF Configuration tab, expand Route Configuration > Static Route by
clicking it; click the icon behind the node and select Insert Instance. Configure the
static route according the data listed in the following table.
Priority 5 5
interface as the target IP address, and the interfaces connecting the primary and secondary RSGs
operate in active/standby dual-receiving state.
Configuration Objects
Active and standby routes need to be configured for the primary and secondary RSGs on the
bearer network
Configuration Roadmap
If the active and standby interfaces have been planned and the RNC supports the dual-receiving
function of these interfaces, you can configure active and standby routes to ensure that the
primary/secondary RSG relationship is consistent with that on the RNC side. This guarantees
millisecond-level fault detection and protection when the primary RSG or the AC link on the
primary RSG is not functioning properly. The RNC uses the IP address of a logical interface as
the target IP address.
l Configure private IGP for subinterfaces between the RSGs to determine the primary/
secondary RSG relationship. IS-IS is used as an example.
l Configure static routes from the primary and secondary RSGs to a logical interface on the
RNC, and import the routes to IS-IS.
l Advertise private IS-IS and static routes to BGP.
NOTE
Unlike VRRP configuration, when you configure active and standby routes, VPN instances use physical
interfaces rather than VLANIF interfaces.
Operation Procedure
Configure private network IS-IS:
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. In the Set Filter Criteria dialog box, click Filter.
3. Select a service to be configured, and click Modify. The Modify L3VPN Service window
is displayed.
4. Select primary and secondary RSGs from the node list, and click Details in the lower left
area. Then VRF Configuration is displayed in the lower right area.
5. On the VRF Configuration tab, expand Route Configuration > ISIS by clicking it; click
the icon behind the ISIS node and select Insert Instance. Then expand the newly-inserted
node and modify its configuration according to the data plan.
Instance ID 2 2
6. On the VRF Configuration tab, choose Route Configuration > ISIS > ISIS Instance >
Route Import > External Route Import for the newly-inserted route instance, and modify
related parameters according to the data plan.
NOTE
To import multiple routes, click the icon behind External Route Import and select Insert Instance.
7. On the VRF Configuration tab, choose Route Configuration > ISIS > ISIS Instance >
Protocol Interface > Protocol Interface > Interface Name for the newly-inserted route
instance, and modify related parameters according to the data plan.
On primary and secondary RSGs, configure a static route destined to the RNC.
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. In the Set Filter Criteria dialog box, click Filter.
3. Select the service to be configured and click Modify. The Modify L3VPN Service window
is displayed.
4. Click Details and then the VRF Configuration tab.
5. Choose Route Configuration > Static Route > Static Route Object from the service tree.
6. Configure a static route according to the data plan.
NOTE
If multiple static routes exist, click the icon next to Static Route and select Insert Instance.
Priority 5 50
Instance ID 2 2
NOTE
You can also click next to the Route Import parameter to add a route import instance.
1. Choose Route Management > IS-IS Route > IS-IS Process from Service Tree in the NE
Explorer, and in the dialog box that is displayed, click Query.
2. Select a process to be configured, click Configure. The Configure IS-IS Process dialog
box is displayed.
3. Click the Advanced tab, and click Set in the IS-IS Adjustment and Optimization area.
Set parameters and click OK.
Level-2 Flash Select this parameter. The Select this parameter. The default
Flood default value is used. value is used.
Follow-up Procedure
When configuring active and standby routes, configure static routes on the RNC. Ensure that
the routes are destined to the primary and secondary RSGs.
Verify Configurations
This topic describes how to check whether configurations are correct.
VRF Ping
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Select the desired Layer 3 Virtual Private Network (L3VPN) service and click the Service
Link tab.
3. Right-click on the tab and choose Fast Diagnose from the shortcut menu.
4. In the VRF Ping dialog box, click Run.
5. The result is Success.
NOTE
For a peer relationship between ASGs and RSGs, configure it between the primary ASG and primary
RSG, or between the secondary ASG and secondary RSG with a priority. The ping operation will be
performed between each pair of peers. If the test result is successful for the priority peer relationship
but failed for non-priority peer relationship, the test is successful. If a peer relationship is configured
between the primary ASG and secondary RSG, ping packets are transmitted from the primary ASG
to the secondary RSG but returned from the secondary RSG to the secondary ASG, resulting in a
ping failure.
VRF Traceroute
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. Right-click a Layer 3 virtual private network (L3VPN) service to be configured and choose
Test and Check from the shortcut menu. The Test and Check window is displayed.
3. Click the Diagnosis tab and select VRF Traceroute.
4. Click OK.
5. After test is complete, Result is Operation Succeeded.
To use the TE tunnel, configure new tunnels between the CSG and the primary and secondary
ASGs before service configuration. For details, see Configuring MPLS TE Tunnels.
Configuring PWs
This topic describes how to configure primary and backup PWs destined to aggregation site
gateways (ASGs) on the cell site gateway (CSG).
Configuration Object
Configure PWs from the CSG to primary and secondary ASGs.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Select the PWE3 service template created in Creating a PWE3
Template.
3. (Optional) Click Configure. In the Configure Ethernet Interface window, click the
Physical Feature tab, and set the Working Mode and Negotiation Rate for the service
access interface.
NOTE
The CSG and base station must have the same interface settings.
4. Click OK.
5. Click OK.
6. Select the VE interface. Then, click the SAI Configuration tab and create a VE subinterface
by setting its ID and VLAN ID.
7. Click OK.
8. On the Physical Topology tab, right-click the secondary ASG and choose Select
Protection-Sink from the shortcut menu. Then, configure the secondary ASG by referring
to the preceding steps.
3. Click OK.
Step 6 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 8 After the PWE3 service is created successfully, the Operation Result dialog box is displayed.
Click Browse Trail to view the PWE3 configuration results.
Running Status is Up, Alarm Severity is Normal, Deployment Status is Deployed, and
Enabling Status is Enabled.
----End
Configuration Object
Add L3VPN interfaces on the primary and secondary ASGs.
1. Choose Service > L3VPN Service > Manage L3VPN Service from the main menu.
2. In the Set Filter Criteria dialog box, click Filter.
3. Select the desired L3VPN service and click Modify. The Modify L3VPN Service dialog
box is displayed.
4. Select the primary and secondary ASGs in Node List and click Details in the lower-left
part. The VRF Configuration tab is displayed in the lower-right part.
5. Configure the service access interface.
a. On the VRF Configuration tab, click the icon next to SAI and choose Insert
Instance.
b. Double-click in the cell at the intersection of the primary ASG column and the
Interface row, and click .... In the dialog box that is displayed, select a Layer 3 VE
interface or subinterface for transmitting the L3VPN service.
c. If no appropriate interface is available, click Create > VE. The Create VE
Interface dialog box is displayed.
d. Click the General tab and set Interface No. according to the data plan.
e. Click the Ethernet Feature tab and set Working Mode and VE-Group ID for the
VE-Group according to the data plan.
Configuration Process
This topic describes the process of deploying PWE3 services and related protection protocols.
Multihop PWE3s are used to carry TDM services between the cell site gateway (CSG) and radio
service gateways (RSGs). Configuration processes are described by allowing for two live-
network scenarios: building a new network and adding a base station.
NOTE
In the network topology, ASGs 3 and 4 respectively function as primary and secondary ASGs, and RSGs 5 and
6 respectively function as primary and secondary RSGs.
Configure BFD for PW on the primary and backup PWs between the CSG and RSGs to
accelerate PW fault detection.
Data Planning
You must plan data as needed before deploying Pseudo Wire Emulation Edge-to-Edge (PWE3)
services and relevant protection protocols.
Table 4-88 TDM service interface planning for the RNC side
No. 1 N/A
Table 4-89 TDM service interface planning for the base station side
Configuration Object
Configure management PWs between primary and secondary RSGs.
Data Plan
Parameter Primary RSG (RSG5) Secondary RSG (RSG6)
Remote BFD The remote BFD ID must be The remote BFD ID must be
ID consistent with the local BFD ID of consistent with the local BFD ID of
the peer NE. the peer NE.
BFD PW1: Cpos port (for TDM services) PW1: Cpos board (for TDM
detection or ATM port (for ATM services) services) or ATM board (for ATM
PW2: Cpos board (for TDM services)
services) or ATM board (for ATM PW2: Cpos port (for TDM services)
services) or ATM port (for ATM services)
NOTE
One side of the BFD detection object of
primary and secondary RSGs is the AC
interface of the management PW, and
the other side is the board where the
management PW resides. RSG_to_ac:
Indicates the BFD session that detects
the AC interface where the management
PW resides. RSG_to_aps: Indicates the
BFD session that detects the board
where the management PW resides.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set Service Type to Management PW and set other parameters as planned.
On the Service Topology tab, right-click and select Create LDP Remote Peer to create an LDP
remote peer quickly.
Step 9 The Operation Result prompt is displayed. Click Browse Trail to view the configuration
results. If the PWE3 service is successfully configured, Running Status is Up.
Step 10 Right-click the PWE3 service in the service list, and choose Configure BFD from the shortcut
menu. The BFD Session Configuration Management dialog box is displayed.
Step 11 Click Create. The Batch Configure BFD Session dialog box is displayed.
Step 12 Click Configure. In the dialog box that is displayed, set BFD parameters for each NE and click
OK after parameters are set. Set key parameters according to the following requirements, and
set the other parameters as required or use default values.
BFD Name Set the BFD name according to the data plan. If you do not set it, the
system automatically allocates one.
Detection Object Click Configure next to Detection Object. In the dialog box that is
displayed,
l For the primary RSG: select Monitoring Interface, click ..., and
select the Cpos port (for TDM services) or ATM port (for ATM
services).
l For the secondary RSG: select Interface Card Index and select the
Cpos board (for TDM services) or ATM board (for ATM services).
Local BFD ID The local BFD ID must be consistent with the remote BFD ID of the
peer NE.
Remote BFD ID The remote BFD ID must be consistent with the local BFD ID of the
peer NE.
Min.Sending 100
Interval
Min.Receiving 100
Interval
Step 14 Repeat steps 1-13 to create a PW between primary and secondary ASGs and bind a BFD session
to the PW according to the data plan.
----End
Configuring E-APS
When APS protection needs to be between the active and standby CSG->RSG PWs or between
RSG nodes, you can configure E-APS on the service interface of primary and secondary RSGs
to implement APS switching between RSGs in case of emergency. For E-APS between RSG
nodes, you can choose either 1+1 or 1:1 protection.
Configuration Object
l For APS protection between the active and standby CSG->RSG PWs, configure primary
and secondary RSGs as the left and right nodes of E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 2 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 4 In the Create E-APS dialog box, set the related parameters.
NOTE
l E-APS 1+1 has four types: single-ended non-revertive, single-ended revertive, dual-ended non-revertive,
and dual-ended revertive. Single-ended non-revertive E-APS 1+1 is recommended.
l E-APS 1:1 has two types: dual-ended non-revertive and dual-ended revertive. Dual-ended revertive E-APS
1:1 is recommended.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as the left node and RSG6 (secondary RSG)
as the right node.
APS
APS Group ID Sets this parameter as planned. The IDs for the local and peer NEs must
be the same.
Local IP Specifies the IP address of the primary or secondary RSG as the local
IP address. The IP address of the RSG loopback interface is generally
used. The local IP address of the left node and the peer IP address of
the right node must be consistent.
Peer IP The local IP address of the local NE must be the same as the peer IP
address of the peer NE.
----End
Configuration Object
The Cpos interface must be added to the Cpos-Trunk interface because the Cpos interface is
used for configuring E-APS that implements link protection between the RSG and the RNC side.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Cpos-Trunk Interface.
Step 4 In the Create Cpos-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. on this tab page.
2. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
interfaces to be added from the Available Interface list on the left and click .
All selected interfaces are added to the Selected Interface list. Click OK.
NOTICE
l Before configuring the Cpos-Trunk interface, make sure that E-APS has been configured.
l The "DS1 list" and the Cpos-Trunk interface cannot be configured at the same time. It can
only be configured in the Cpos-Trunk interface that already exists.
Step 5 Click OK. The Create Cpos-Trunk Interface dialog box is closed.
Step 6 Configure Cpos-Trunk interfaces on the secondary RSG in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
In Physical Topology in the upper-right part, right-click the primary ASG, and choose Set As
Switching Node > Protection from the shortcut menu.
Step 10 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This section describes the process of configuring single-homed MS-PW TDM services and
protection.
As shown in the following figure, MS-PWs are established between the cell site gateway (CSG)
and radio service gateway (RSG).
The following table shows the process of configuring single-homed MS-PW services.
Deleting the Default Timeslot on a Cpos Deleting the Default Timeslot on a Cpos
Interface Interface
Verifying Configurations
NOTICE
If the hot backup or APS protection is deployed for tunnels carrying ATM or TDM services,
ensure that the detection period of BFD for PW is longer than the latency of LSP or APS
switchover. This prevents repeated switchover.
Data Plan
To deploy single-homed MS-PW TDM services and protection, plan the following data.
Table 4-93 TDM service interface planning for the RNC side
No. 1 N/A
Table 4-94 TDM service interface planning for the base station side
Configuration Object
l Select the primary RSG as both the left and right NEs for E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as both the left and right nodes.
APS
Parameter Settings
APS Group ID Sets the APS group ID according to the data plan. The left and right
nodes have the same group ID.
Step 5 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 6 (Optional) Set the RSG ATM port (for the ATM service) connected to the RNC side to the UP
state when receiving optical signals. When the working mode of the protection group is 1+1
unidirectional switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Object
Configure the RSG.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Cpos-Trunk Interface.
Step 4 In the Create Cpos-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. on this tab page.
2. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
interfaces to be added from the Available Interface list on the left and click .
All selected interfaces are added to the Selected Interface list. Click OK.
NOTICE
l Before configuring the Cpos-Trunk interface, make sure that E-APS has been configured.
l The "DS1 list" and the Cpos-Trunk interface cannot be configured at the same time. It can
only be configured in the Cpos-Trunk interface that already exists.
Step 5 Click OK. The Create Cpos-Trunk Interface dialog box is closed.
Step 6 Configure Cpos-Trunk interfaces on the secondary RSG in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
Step 7 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 9 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This topic describes the process of deploying PWE3 services and related protection protocols.
In the mixed VPN solution, the multihop PWE3 is used to carry asynchronous transfer mode
(ATM) services between the cell site gateway (CSG) and radio service gateways (RSGs).
Configuration processes are described by allowing for two live-network scenarios: building a
new network and adding a base station.
NOTE
In the network topology, ASGs 3 and 4 respectively function as primary and secondary ASGs, and RSGs 5 and
6 respectively function as primary and secondary RSGs.
Data Plan
To deploy PWE3 services and related protection protocols, plan the following data.
Channel Set ID 1 -
Table 4-100 ATM interface planning for the base station side
Configuration Object
Configure management PWs between primary and secondary RSGs.
Data Plan
Parameter Primary RSG (RSG5) Secondary RSG (RSG6)
Remote BFD The remote BFD ID must be The remote BFD ID must be
ID consistent with the local BFD ID of consistent with the local BFD ID of
the peer NE. the peer NE.
BFD PW1: Cpos port (for TDM services) PW1: Cpos board (for TDM
detection or ATM port (for ATM services) services) or ATM board (for ATM
PW2: Cpos board (for TDM services)
services) or ATM board (for ATM PW2: Cpos port (for TDM services)
services) or ATM port (for ATM services)
NOTE
One side of the BFD detection object of
primary and secondary RSGs is the AC
interface of the management PW, and
the other side is the board where the
management PW resides. RSG_to_ac:
Indicates the BFD session that detects
the AC interface where the management
PW resides. RSG_to_aps: Indicates the
BFD session that detects the board
where the management PW resides.
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set Service Type to Management PW and set other parameters as planned.
Step 9 The Operation Result prompt is displayed. Click Browse Trail to view the configuration
results. If the PWE3 service is successfully configured, Running Status is Up.
Step 10 Right-click the PWE3 service in the service list, and choose Configure BFD from the shortcut
menu. The BFD Session Configuration Management dialog box is displayed.
Step 11 Click Create. The Batch Configure BFD Session dialog box is displayed.
Step 12 Click Configure. In the dialog box that is displayed, set BFD parameters for each NE and click
OK after parameters are set. Set key parameters according to the following requirements, and
set the other parameters as required or use default values.
BFD Name Set the BFD name according to the data plan. If you do not set it, the
system automatically allocates one.
Detection Object Click Configure next to Detection Object. In the dialog box that is
displayed,
l For the primary RSG: select Monitoring Interface, click ..., and
select the Cpos port (for TDM services) or ATM port (for ATM
services).
l For the secondary RSG: select Interface Card Index and select the
Cpos board (for TDM services) or ATM board (for ATM services).
Local BFD ID The local BFD ID must be consistent with the remote BFD ID of the
peer NE.
Remote BFD ID The remote BFD ID must be consistent with the local BFD ID of the
peer NE.
Min.Sending 100
Interval
Min.Receiving 100
Interval
Step 14 Repeat steps 1-13 to create a PW between primary and secondary ASGs and bind a BFD session
to the PW according to the data plan.
----End
Configuring E-APS
When APS protection needs to be between the active and standby CSG->RSG PWs or between
RSG nodes, you can configure E-APS on the service interface of primary and secondary RSGs
to implement APS switching between RSGs in case of emergency. For E-APS between RSG
nodes, you can choose either 1+1 or 1:1 protection.
Configuration Object
l For APS protection between the active and standby CSG->RSG PWs, configure primary
and secondary RSGs as the left and right nodes of E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
NOTE
l E-APS 1+1 has four types: single-ended non-revertive, single-ended revertive, dual-ended non-revertive,
and dual-ended revertive. Single-ended non-revertive E-APS 1+1 is recommended.
l E-APS 1:1 has two types: dual-ended non-revertive and dual-ended revertive. Dual-ended revertive E-APS
1:1 is recommended.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as the left node and RSG6 (secondary RSG)
as the right node.
APS
APS Group ID Sets this parameter as planned. The IDs for the local and peer NEs must
be the same.
NOTE
APS Group ID for an ATM interface that has been added to the ATM-Trunk
cannot be set or modified. To set or modify APS Group ID, remove the ATM
interface from the ATM-Trunk.
Local IP Specifies the IP address of the primary or secondary RSG as the local
IP address. The IP address of the RSG loopback interface is generally
used. The local IP address of the left node and the peer IP address of
the right node must be consistent.
Peer IP The local IP address of the local NE must be the same as the peer IP
address of the peer NE.
Parameter Settings
Step 5 (Optional) Set the RSG ATM port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command to enter the system view.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Objects
The ATM interfaces that are used for configuring E-APS need to be added to Atm-Trunk
interfaces.
ATM service interfaces need to be configured on the primary and secondary RSGs.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 3 On the Interface Information tab page, click Create and choose Create Main Interface >
Atm-Trunk Interface.
Step 4 In the Create Atm-Trunk Interface dialog box, set the relevant parameters.
1. Click the General tab and set Interface No. according to the data plan.
2. (Optional) Click the ATM Feature tab and select ATM Cell Transfer. To use the ATM
cell transfer mode, select ATM Cell Transfer; to use a non-transfer mode, deselect it. (The
ATM cell transfer mode requires support of ATM subboards.)
3. Click the Member Interface tab and click Add. In the dialog box that is displayed, select
the desired interface from the Available Interface list on the left and click . The
selected interface is added to the Selected Interface list. Then click OK.
4. Click OK. The Create Atm-Trunk Interface dialog box is closed.
5. On the Interface Information tab page, select the configured ATM-Trunk interface, right-
click, and choose Synchronize from the shortcut menu. In the lower part of the window,
the value of Operating Status is Up.
Step 5 Set the working mode of ATM subboards to ATM cell transfer mode.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the set service-mode slot slotid cell-concatenation-mode command. slotid is the ID
of the slot where the ATM subboard resides.
5. Close the CLI window.
----End
Configuration Objects
ATM service interfaces need to be configured for all CSGs.
Procedure
Step 1 Configure an E1 interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose Interface Management > Interface Information from the service tree.
3. Select the desired E1 interface, such as E1 0/2/1, and click Configure.
4. In the Configure E1 Interface dialog box, click the Physical Feature tab.
5. In the Timeslot Configuration area, click Add.
6. In the Add Timeslot Binding dialog box, set No. and Timeslot Sequence according to the
planning.
7. Click OK. The Add Timeslot Binding dialog box is closed.
8. Click OK. The Configure E1 Interface dialog box is displayed. After you click Query,
serial interfaces named in the format of "E1 interface number + sequence number", such
as Serial 0/2/1:1, are displayed on the Interface Information tab page.
9. Configure other E1 interfaces that need to be bound to an Inverse Multiplexing Over ATM
(IMA) group in the same manner.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes of PWE3 services. Set a PWE3 service profile that already exists on the
Creating a PWE3 Template as a service profile.
In Physical Topology in the upper-right part, right-click the primary ASG CX600–CC-001, and
choose Set As Switching Node > Working from the shortcut menu.
In Physical Topology in the upper-right part, right-click the secondary ASG CX600–DD-001,
and choose Set As Switching Node > Protection from the shortcut menu.
Step 11 (Optional) Configure a PW template. This step is required only when the ATM subboard does
not support cascading.
1. In the left-hand pane, click Detail.
2. In the details area, click the Advanced PW Attribute tab.
3. Respectively click the cells under Source PW Template and Sink PW Template and click
the "..." button that is displayed. Then, select the PW template that has been created in
Configuring a PW Template for ATM Services in the dialog box that is displayed.
4. Configure the source and sink templates for other PWs in the same manner.
Step 12 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This section describes the process of configuring single-homed MS-PW ATM services and
protection.
As shown in the following figure, MS-PWs are established between the cell site gateway (CSG)
and radio service gateway (RSG).
4. Configure MS-PW services on the CSG and RSG, and PW exchange on ASGs.
5. Configure static BFD for PW between the CSG and RSG to accelerate the switchover
between the primary and backup PWs in case of faults.
NOTICE
If the hot backup or APS protection is deployed for tunnels carrying ATM or TDM services,
ensure that the detection period of BFD for PW is longer than the latency of LSP or APS
switchover. This prevents repeated switchover.
Data Plan
To deploy single-homed MS-PW ATM services and protection, plan the following data.
Channel Set ID 1 —
Table 4-106 ATM interface planning for the base station side
Min. Receiving 50 -
Interval(ms)
Min. Sending 50 -
Interval(ms)
Configuration Object
l Select the primary RSG as both the left and right NEs for E-APS.
l E-APS also needs to be configured on the base station controller (BSC) connected to the
RSGs. For details about the E-APS configuration on the BSC, see BSC manuals.
Procedure
Step 1 Choose Configure > Node Redundancy > E-APS Management from the main menu.
Step 3 In the Create E-APS dialog box, set the related parameters.
Parameter Settings
NE Name Sets RSG5 (primary RSG) as both the left and right nodes.
APS
APS Group ID Sets the APS group ID according to the data plan. The left and right
nodes have the same group ID.
Step 5 (Optional) Set the RSG Cpos port connected to the RNC side to the UP state when receiving
optical signals. When the working mode of the protection group is 1+1 unidirectional
switching, set this parameter.
1. In the NE Explorer, right-click the RSG, choose Service Tree > Interface Management
> Interface Information, and click Query.
2. Select the Cpos interface, and click Configure. The Configure Cpos Interface dialog box
is displayed.
3. On the Physical Feature tab, select Hold Up.
4. Click OK.
Step 6 (Optional) Set the RSG ATM port (for the ATM service) connected to the RNC side to the UP
state when receiving optical signals. When the working mode of the protection group is 1+1
unidirectional switching, set this parameter.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the interface interface-type interface-number command to enter the ATM interface
view.
5. Run the hold-up command.
6. Close the CLI window.
----End
Configuration Objects
ATM service interfaces need to be configured for all CSGs.
Procedure
Step 1 Configure an E1 interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose Interface Management > Interface Information from the service tree.
3. Select the desired E1 interface, such as E1 0/2/1, and click Configure.
4. In the Configure E1 Interface dialog box, click the Physical Feature tab.
5. In the Timeslot Configuration area, click Add.
6. In the Add Timeslot Binding dialog box, set No. and Timeslot Sequence according to the
planning.
7. Click OK. The Add Timeslot Binding dialog box is closed.
8. Click OK. The Configure E1 Interface dialog box is displayed. After you click Query,
serial interfaces named in the format of "E1 interface number + sequence number", such
as Serial 0/2/1:1, are displayed on the Interface Information tab page.
9. Configure other E1 interfaces that need to be bound to an Inverse Multiplexing Over ATM
(IMA) group in the same manner.
----End
Configuration Object
Configure the RSG.
Procedure
l If the NodeB supports APS protection, you are advised to use the ATM-Trunk interface.
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut
menu.
2. Choose Interface Management > Interface Information from the service tree.
3. On the Interface Information tab page, click Create and choose Create Main
Interface > Atm-Trunk Interface.
4. In the Create Atm-Trunk Interface dialog box, set the relevant parameters.
a. Click the General tab and set Interface No. according to the planning.
b. (Optional) Click the ATM Feature tab and select ATM Cell Transfer. To use
the ATM cell transfer mode, select ATM Cell Transfer; to use a non-transfer
mode, deselect it. (The ATM cell transfer mode requires support of ATM
subboards.)
c. Click the Member Interface tab and click Add. In the dialog box that is
displayed, select the desired interface from the Available Interface list on the
left and click . The selected interface is added to the Selected
Interface list. Then click OK.
d. Click OK. The Create Atm-Trunk Interface dialog box is closed.
e. On the Interface Information tab page, select the configured ATM-Trunk
interface, right-click, and choose Synchronize from the shortcut menu. In the
lower part of the window, the value of Operating Status is Up.
l If the base station does not support APS protection, the ATM interface is recommended.
In this situation, the ATM interface does not need to be configured.
l Set the working mode of ATM subboards to ATM cell transfer mode.
1. In the Main Topology, right-click an RSG and choose Tools > Telnet from the shortcut
menu.
2. In the dialog box that is displayed, enter the user name and password of the login NE.
3. Run the system-view command. The system view is entered.
4. Run the set service-mode slot slotid cell-concatenation-mode command. slotid is
the ID of the slot where the ATM subboard resides.
5. Close the CLI window.
----End
Procedure
Step 1 Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
Step 2 Set basic attributes. Set a PWE3 service profile that already exists on the Creating a PWE3
Template as a service profile.
Step 7 (Optional) Set the PW ID according to the data plan or enable auto-assignment.
Step 9 (Optional) Configure a PW template. This step is required when the ATM subboard does not
cascading.
1. In the left-hand pane, click Detail.
3. Respectively click the cells under Source PW Template and Sink PW Template and click
the "..." button that is displayed. Then, select the PW template that has been created in
Configuring a PW Template for ATM Services in the dialog box that is displayed.
4. Configure the source and sink templates for other PWs in the same manner.
Step 10 Click Detail in the lower right part of left pane, and click the Service Parameter tab in the lower
part of right pane. Set Reversion Delay Time to 500.
Step 11 Click Apply or OK to apply PWE3 services to NEs. The Operation Result prompt is displayed.
Click Browse Trail to view PW configurations. Running Status is Up, Alarm Severity is
Normal, Deployment Status is Deployed, and Enabling Status is Enabled.
NOTE
Select the service to be configured, right-click a blank area on the Topology tab, and select Legend to view
legend descriptions of the physical topology view. Legends help user learn object types and status of each legend
in the physical topology view.
----End
Verifying Configurations
This topic describes how to verify configurations.
VCCV Ping
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click the desired service and choose Test And Check from the shortcut menu.
4. In the Test And Check dialog box, choose Diagnosis Option > OAM Tool > VCCV
Ping in the Diagnosis Option area.
5. (Optional)Click the button next to VCCV Ping and set advanced parameters:
a. If there is no direct route between the CSG and RSG, click the button next to VCCV
Ping and change Response Mode to Application Control Channel.
b. For switch nodes, set VCCV Capability Type to Lable Alart; for other nodes, select
Control Word.
6. Click Run.
7. After VCCV test is completed, test results are displayed in the lower Check Result area,
among which Check Result is displayed as Operation Succeeded.
Connectivity Test
NOTE
For ATM services, set the LLID before performing connectivity tests. You can set or query the LLID by choosing
Service Tree > Reliability > OAM Management > ATM OAM Management > Global ATM OAM
Configuration in the NE Explorer.
1. Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
2. In the Set Filter Criteria dialog box, set search criteria and click Filter. All the qualified
services are displayed in the search result area.
3. Right-click a service to be tested and choose Connectivity Test from the shortcut menu.
4. In the Connectivity Test dialog box, set the source and sink loopback status, and click
Start.
5. After the test is complete, the Check Result is displayed as Operation Succeeded.
Configuration Process
This topic describes the process for configuring SD bit error detection.
l Configure the MPLS label distribution mode to non-null using the U2000 IP plug-and-play
management function.
l Configure bidirectional LSPs on the U2000.
l Configure bit error detection thresholds for ports on the U2000.
l For the MPLS L2VPN service with the PW redundancy protection, configure SD bit error
detection for AC interfaces and intermediate nodes (multi-segment PWs) on the U2000 to
trigger protection switching.
Configuration Object
Configure bit error detection thresholds for ports on links to be tested.
NOTE
You can use a template of the U2000 IP plug-and-play management function to bulk configure the thresholds.
Procedure
Step 1 Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
Step 2 Choose Interface Management > Interface Information from the service tree.
Step 5 In the dialog box that is displayed, click the Monitor Trap Threshold tab, select the CRC
Packet error ratio check box, and set Alarm threshold Coefficient, Resume threshold
Coefficient, Alarm threshold exponent, and Resume threshold exponent according to the
data plan.
Step 6 Select the Trigger LSP check box.
----End
Configuration Object
Configure SD bit error detection on the source and sink nodes of primary and backup tunnels
on the bearer network.
Procedure
Step 1 Choose Service > Tunnel > Manage Tunnel from the main menu.
Step 2 In the Set Filter Criteria dialog box, set filter criteria and click Filter. All services meeting the
filter criteria are displayed.
Step 3 In the service list, select the tunnel for which to configure bit error detection. In the lower pane,
click the Bit Error Detection tab.
Step 4 Set Bit Error Detection Mode to Bidirectional.
Step 5 Click Select. In the Select Tunnel dialog box, select the mapping backward tunnel, and click
OK.
----End
Configuration Object
Configure SD bit error detection on primary and backup PWs for low-speed services.
Procedure
Step 1 Choose Service > PWE3 Service > Manage PWE3 Service from the main menu.
Step 2 In the Set Filter Criteria dialog box, set filter criteria and click Filter. All services meeting the
filter criteria are displayed.
Step 3 In the service list, right-click the desired PWE3 service and choose Bit Error Detect >
Enable from the shortcut menu.
----End
Configuration Roadmap
Different clock deployment solutions are available for different synchronization requirements.
Multiple technologies can be used to transparently transmit clock signals. The recommended
solution is: using 1588v2 to achieve time synchronization, using synchronous Ethernet to
achieve frequency synchronization, and selecting sources according to Synchronization Status
Message (SSM).
l To achieve frequency synchronization using synchronous Ethernet, see Selecting the
Clock Source and Configuring Synchronous Ethernet Clock.
l To achieve time synchronization using 1588v2, see Selecting the Clock Source,
Configuring Synchronous Ethernet Clock, and Configuring the 1588v2 Clock.
NOTE
In this topology, ASG3 acts as the primary ASG, ASG4 as the secondary ASG, RSG5 as the primary RSG, and
RSG6 as the secondary RSG.
For the output clock interface, do not set a priority but enable clock synchronization. For the input clock interface,
set a priority according to the clock plan and enable clock synchronization.
In this scheme, the synchronous Ethernet clock is used to implement frequency synchronization
and the 1588v2 clock is used to implement time synchronization.
l Synchronous Ethernet clock
A clock priority must be configured for every NE interface to prevent clock loops.
l 1588v2 clock
All the NEs reside in a 1588v2 clock domain and the primary and secondary RSGs have
external clock sources. The clock priorities for the primary and secondary RSGs must be
higher than those for other NEs and the clock priority for the primary RSG must be higher
than that for the secondary RSG. The clock tracing relationship in the clock domain is
determined by the Best Master Clock (BMC) algorithm.
Data Planning
Plan different parameter values based on the different requirements of frequency
synchronization and time synchronization.
l In this document, the RSGs are CX600-X8s and each RSG has three clock ports: bits0,
bits1, and bits2. The three clock ports can be used for both frequency synchronization and
phase synchronization. In this example, port bits2 is used to receive frequency
synchronization signals and port bits0 is used to receive time synchronization signals.
l For synchronous Ethernet, source selection control is implemented by enabling SSM and
configuring clock signal priorities in the local priority list.
NOTE
For clock synchronization of synchronous Ethernet, the source selection sequence is: SSM clock quality
> local priority setting > clock source type.
l The priority list of SSM clock qualities is: PRC > SSUA > SSUB > SEC > DNU. Source selection
does not involve the sources not configured with priorities or with the quality of DNU.
l In local settings, the priority value can be set to 1 to 255. Smaller numbers indicate higher priorities.
Source selection does not involve the sources not configured with priorities.
l The priority of a BITS clock source is higher than a clock source connected to a service port.
l The dynamic BMC source selection algorithm is run for 1588v2.
NOTE
When the BMC algorithm is used by a 1588v2-enabled device for source selection, priority1 of each
candidate time source is compared first, then the clock-class, clock-accuracy, and priority2. If priority1
of candidate time sources is the same, the clock-class is compared, and so on. The time source with the
highest priority is selected as the master clock. In this example, it is recommended that priority2 be used
for clock source selection. Retain the default settings for priority1, clock-class, and clock-accuracy.
RS Clock input type 2mhz The value can be 2mhz or 2mbps. The
G5 default value is 2mbps.
GE1/0/0 -
RS Clock input type 2mhz The value can be 2mhz or 2mbps. The
G6 default value is 2mbps.
GE1/0/0 -
GE0/2/1 20
6
Importing Links
This topic describes how to import links to generate a clock topology before clock deployment.
Procedure
Step 1 Choose Inventory > Fiber/Cable/Microwave Link > Fiber/Cable/Microwave Link
Management from the main menu. The Fiber/Cable/Microwave Link Management window
is displayed.
Step 2 Right-click in a blank area and choose Import Link from the shortcut menu. The Import
Link dialog box is displayed.
----End
Configuration Object
Perform configurations on the primary and secondary radio service gateways (RSGs) on the
bearer network.
Procedure
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose System Management > Clock Management > Physical Clock Management
from the navigation tree. Then, click the Other Clock Source subtab on the Clock
Source tab.
3. Select the bits0 clock source, and set parameters on the General tab as follows:
l Select the Enable Clock check box.
l Set SSM Source Select Mode to Manual.
l Set Input SSM Class to Prc.
l Select the System Priority check box.
l Set System Priority to 10 (10 for the primary RSG and 20 for the secondary RSG)
l Set Clock Type to 2Mhz.
l Retain the default values of other parameters.
NOTE
In this example, external BITS signals are 2 MHz signals. If BITS signals are 2 Mbps signals, you do
not need to set the SSM Source Select Mode and Input SSM Class parameters, but need to set Clock
Type to 2Mbit/s.
4. Select the bits1 clock source, and set parameters on the General tab as follows:
l Set Clock Type to 1pps.
l Set Direction to In.
l Retain the default values of other parameters.
5. On the Physical Clock Management tab, click the General subtab and set TOD
Format to Ubx.
6. (Optional) On the Clock Source tab, click the Other Clock Source subtab, select the
ptp clock source, and set parameters in the lower pane as follows:
NOTE
This step is mandatory when IEEE 1588v2 is deployed.
7. Click Apply.
NOTE
A clock source can be used only when it is in the normal state.
Configuration Objects
Synchronous Ethernet clock needs to be configured for all NEs on the bearer network.
Procedure
1. Right-click the NE in the Main Topology and choose NE Explorer from the shortcut menu.
2. Choose System Management > Clock Management > Physical Clock Management
from the service tree. Then click the General tab and set relevant clock parameters.
l Select Enable Ethernet Synchronization.
l Select SSM Control.
l Use the default values for other parameters.
3. Click the Clock Source tab and then the Port Clock tab. Click Add. The Select
Interface dialog box is displayed.
4. Select the interface that connects RSG5 to RSG6 and click OK.
5. Select this interface, set the relevant parameters on the General tab page, and click Apply
NOTE
For the output clock interface, do not set a priority but enable clock synchronization. For the input
clock interface, set a priority according to the clock plan and enable clock synchronization.
For example, GE interface 1/1/2 is an output clock interface; therefore, enable clock
synchronization for it; GE interface 2/1/0 is an input clock interface and the interface
priority is 1; therefore, set the priority to 1 and enable clock synchronization for it.
6. In the dialog box displayed indicating that the operation is successful, click OK.
7. Set clock information for the rest of the NEs according to the planning.
NOTE
Clock synchronization must be enabled for the interface between the CSG and the base station.
Configuration Objects
The 1588v2 clock needs to be configured for all NEs on the bearer network.
Procedure
1. Enable the Precision Time Protocol (PTP) clock.
a. In the NE Explorer, choose System Management > Clock Management > PTP
Clock Management from the service tree. The PTP Clock Management tab page is
displayed.
b. Click the General tab and set the relevant parameters. Then click Apply.
l Select Enable PTP.
l Set Clock Domain according to the planning.
l Set Clock Type according to the planning.
l Select Enable Ring Fiber Asymmetry Measure.
c. On the Port Clock Source tab page, select this interface, set the relevant parameters
on the Basic Information tab page, and click Apply.
l Select Enable PTP.
l Set Delay Mechanism to Pdelay.
l Set Clock Step to One-step.
4. Configure the 1588v2 clock for the rest of the NEs in the same manner.
Verifying Configurations
This topic explains how to verify configurations.
Procedure
Step 1 Select Clock View from the Current View drop-down list in the upper left part of the Main
Topology. Then select an IPRAN subnet from the navigation tree. The clock status of each NE
is displayed.
Step 2 Right-click in the Main Topology and choose Search Clock Link from the shortcut menu. The
Search Clock Link dialog box is displayed. Set the relevant parameters and click OK.
l Select 1588v2 and Synchronous ETH in the Clock Type area.
l Click Search from NE in the Search Mode area.
l Select IPRAN in the NE Search area.
Step 3 In the dialog box that is displayed, click Close. The clock tracing relationships between NEs are
displayed in the clock view. Check whether the relationships are the same as those planned. If
some relationships are different from those planned, check whether the clock parameters are set
according to the planning.
Step 4 Click Legend&Filter&Attribute and select the desired clock type on the Filter tab page.
3. Select a clock source and click Delete. In the dialog box that is displayed, click OK.
You can delete all port clock sources of a device by selecting all of them and clicking
Delete.
4. Click the General tab and select Enable PTP Clock.
5. On the Physical Clock Management tab, select Clock Source > Port Clock Source.
6. Select a clock source and click Delete. In the dialog box that is displayed, click OK.
You can delete all port clock sources of a device by selecting all of them and clicking
Delete.
7. Click the General tab and deselect Enable Ethernet Synchronization.
8. Click Apply.
9. Click Synchronize.
----End
Configuration Object
This solution uses simple traffic classification to deploy QoS and set CAR parameters for the
network interface of CSGs and RSGs.
Configuration roadmap:
l Create Diffserv profile example used to configure the service interface and network
interface of CSGs, ASGs, and RSGs.
NOTE
If priority mapping rules configured in the default profile are appropriate, use the default profile.
l Apply the Diffserv profile to the interfaces.
l Create an HQoS profile used to configure CAR of the network interface of CSGs and RSGs.
Apply the profile to the interface.
Data Plan
AF2 WFQ 10
AF3 WFQ 15
AF4 WFQ 15
BE WFQ 10
AF2 WFQ 10
AF3 WFQ 15
AF4 WFQ 15
BE WFQ 10
Procedure
Step 1 Configure differentiated services for the outbound direction of the CSG user side.
1. In the NE Explorer, right-click the CSG, choose Service Tree > VPN Management >
L3VPN Management > VRF Management, and click Query.
2. Select the VRF and click Configure. The Configure VRF window is displayed.
3. Click Advanced. The Configure Advanced Attributes of VRF window is displayed.
4. Set Down DiffServ Mode to Pipe and click OK.
5. Click Apply.
1. Choose Configuration > IP QoS Profile > DS Domain Profile from the main menu.
2. On the DS Domain Profile tab page, right-click in the blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create DS Domain Profile dialog box, set Name to example. Then configure the
mapping between the Differentiated Services Code Point (DSCP) and Class of Service
(CoS) and set parameters in the Inbound Parameters area. Use the default values for the
parameters in the Outbound Parameters area.
4. Click OK.
Step 4 Disable PHB for the service interface of ASGs and RSGs.
1. In the NE Explorer, right-click the CSG, choose Service Tree > QoS Management >
Configure Interface QoS, and click Query.
2. Select the service interface and click the Other tab.
3. Select Disable PHB.
4. Click Apply.
1. Choose Configuration > IP QoS Profile > HQoS Profile from the main menu.
2. On the HQoS Profile tab page, right-click in the blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create HQoS Profile dialog box, set Name to CSG_UNI and click Add.
4. In the User Queue dialog box, click … next to the Flow Queue Policy text box.
5. In the Select Flow Queue Profile dialog box, right-click in the blank area and choose Add
Global Profile from the shortcut menu.
6. In the Create Flow Queue Profile dialog box, set Name to CSG_UNI. Then set the
relevant parameters according to the planning. Click OK.
7. In the Add User Queue dialog box, set CIR to 4000, PIR to 4000, and Direction to
Outbound. Then click OK.
----End
Configuration Roadmap
Three types of ATM services need to be configured and they are provided by the three user-side
IMA subinterfaces of the CSG and transmitted to the three ATM trunk subinterfaces of the RNC.
On the three IMA subinterfaces of the CSG, three types of ATM services are configured: cbr,
vbrNrt, and vbrRt.
On the three IMA trunk subinterfaces of the RSG, three types of ATM services are configured:
cbr, vbrNrt, and vbrRt.
Data Planning
Procedure
Step 1 Configure an ATM policy profile.
1. Choose Configuration > IP QoS Profile > ATM Policy Profile from the main menu.
2. On the ATM Policy Profile window, right-click a blank area and choose Add Global
Profile from the shortcut menu.
3. In the Create ATM Policy Profile dialog box, set desired parameters according to the data
plan. Click OK.
4. On the ATM Policy Profile window, right-click a profile and choose Download to NE
from the shortcut menu.
5. In the dialog box that is displayed, select the desired NE and click Next. After download
is complete, click Close.
Step 2 Choose Service > PWE3 Service > Manage PWE3 Service from the shortcut menu.
Step 3 In the Set Filter Criteria dialog box, set filter criteria and click Filter. Then all services that
meet the filter criteria are displayed.
Step 4 Select services to be configured from the service list, click the Topology tab, right-click an ATM
interface, and choose Configuration from the shortcut menu.
Step 5 In the Configure ATM Interface dialog box, click the PVC/PVP tab, select PVC, and click
Configure.
Step 6 In the Configure PVC dialog box, click … next to Service Name.
Step 7 In the Select ATM Service dialog box, select the configured ATM policy profile.
Step 11 Configure the other two IMA subinterfaces and the Atm-Trunk interface of the RSG according
to the data plan.
----End