Está en la página 1de 7

Determinación del espesor de la carpeta asfáltica de un pavimento flexible

Datos:

 Confiabilidad periodo de análisis = 99% ; n=2


 So = 0.45
 𝜌𝑜 = 4.2 ; 𝜌𝑡 = 2.2
 Mrsubrasante=62.5[MPa]=9[ksi]
 MrBase=206.84 [MPa] = 30[ksi]
 Mrsub-base=89.63[MPa]=13[ksi]
 Coeficiente estructural (a1=0.44;a2=0.14;a3=0.10)
 W18=ESAL’s=2x106 [ejes]
 Drena en una semana y satura más del 25%
Solución:
1 1
−𝑅𝐷 = 𝑅𝑁 𝑛 = 0.992 = 0.995 = 99.5%
−∆𝑃𝑆𝐼 = 4.2 − 2.2 = 2

Carpeta asfáltica
−𝑆𝑁𝑏𝑎𝑠𝑒 = 3"
−𝑆𝑁1 = 3" ∗ 2.54 ∗ 10 = 76.2 ≈ 77[𝑚𝑚]
𝑆𝑁1 77
−𝐷1 = = = 175[𝑚𝑚] => 𝐷1∗ = 180[𝑚𝑚]
𝑎1 0.44
−𝑆𝑁1∗ = 180 ∗ 0.44 = 79.2[𝑚𝑚]

ING.MARCELO BADANI VILLEGAS 8VO “B”


Capa Base

−𝑆𝑁𝑏𝑎𝑠𝑒 = 4"
−𝑆𝑁2 = 4" ∗ 2.54 ∗ 10 = 101.6 ≈ 102[𝑚𝑚]
𝑆𝑁2 − 𝑆𝑁1∗ 102 − 79.2
−𝐷2 = = = 203.57[𝑚𝑚] => 𝐷2∗ = 210[𝑚𝑚]
𝑎2 ∗ 𝑚2 0.14 ∗ 0.8
−𝑆𝑁2∗ = 210 ∗ 0.14 ∗ 0.8 = 23.5[𝑚𝑚]

Capa Sub-base

−𝑆𝑁𝑠𝑢𝑏𝑏𝑎𝑠𝑒 = 4.6"
−𝑆𝑁3 = 4.6" ∗ 2.54 ∗ 10 = 116.84 ≈ 117[𝑚𝑚]
𝑆𝑁3 − (𝑆𝑁1∗ + 𝑆𝑁2∗ ) 117 − (79.2 + 23.5)
−𝐷3 = = = 178.75[𝑚𝑚] => 𝐷3∗ = 180[𝑚𝑚]
𝑎3 ∗ 𝑚3 0.10 ∗ 0.8
−𝑆𝑁3∗ = 180 ∗ 0.10 ∗ 0.8 = 14.4[𝑚𝑚]

𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁


117.1 > 117[𝑚𝑚]

0.55 206.84[𝑀𝑃𝑎]
𝐶𝐵𝑅 𝑐𝑎𝑝𝑎 𝑏𝑎𝑠𝑒 = √ = 58.33%
22.1

89.63[𝑀𝑃𝑎]
0.55
𝐶𝐵𝑅 𝑐𝑎𝑝𝑎 𝑠𝑢𝑏_𝑏𝑎𝑠𝑒 = √ = 12.75%
22.1

9000
𝐶𝐵𝑅 𝑠𝑢𝑏_𝑟𝑎𝑠𝑎𝑛𝑡𝑒 = = 6%
1500

ING.MARCELO BADANI VILLEGAS 8VO “B”


REDUCIR EL ESPESOR D1

1. Aumentando el CBR de la capa base a 60%

𝑀𝑟 = 22.1 ∗ 𝐶𝐵𝑅 0.55 = 22.1 ∗ 600.55 = 210.08[𝑀𝑃𝑎] = 30.5[𝑘𝑠𝑖]

−𝑆𝑁𝑏𝑎𝑠𝑒 = 2.9"
−𝑆𝑁1 = 2.9" ∗ 2.54 ∗ 10 = 73.66 ≈ 74[𝑚𝑚]
𝑆𝑁1 74
−𝐷1 = = = 169[𝑚𝑚] => 𝐷1∗ = 170[𝑚𝑚]
𝑎1 0.44
−𝑆𝑁1∗ = 170 ∗ 0.44 = 74.8[𝑚𝑚]

D1=17[cm]

𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁


14.4 + 23.5 + 74.8 > 117[𝑚𝑚]
112.7 > 117[𝑚𝑚] (𝑛𝑜 𝑐𝑢𝑚𝑝𝑙𝑒)

ING.MARCELO BADANI VILLEGAS 8VO “B”


2. Aumentando el CBR de la capa base a 80% (más óptimo para esta capa)

𝑀𝑟 = 22.1 ∗ 𝐶𝐵𝑅 0.55 = 22.1 ∗ 800.55 = 246.09[𝑀𝑃𝑎] = 35.7[𝑘𝑠𝑖]

−𝑆𝑁𝑏𝑎𝑠𝑒 = 2.6"
−𝑆𝑁1 = 2.6" ∗ 2.54 ∗ 10 = 66.04 ≈ 67[𝑚𝑚]
𝑆𝑁1 67
−𝐷1 = = = 153[𝑚𝑚] => 𝐷1∗ = 160[𝑚𝑚]
𝑎1 0.44
−𝑆𝑁1∗ = 160 ∗ 0.44 = 70.4[𝑚𝑚]

D1=16[cm]

𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁


14.4 + 23.5 + 70.4 > 117[𝑚𝑚]
108.3 > 117[𝑚𝑚] (𝑛𝑜 𝑐𝑢𝑚𝑝𝑙𝑒)

ING.MARCELO BADANI VILLEGAS 8VO “B”


3. Aumentando el grosor de la capa base de D2=210[mm] a D2=300[mm] que
es la máxima

−𝐷2 = 300[𝑚𝑚]
𝑆𝑁2 − 𝑆𝑁1∗ 102 − 𝑆𝑁1∗
−𝐷2 = = = 300[𝑚𝑚]
𝑎2 ∗ 𝑚2 0.14 ∗ 0.8
−𝑆𝑁2∗ = 300 ∗ 0.14 ∗ 0.8 = 33.6[𝑚𝑚]
−𝑆𝑁1∗ = 102 − 300(0.14 ∗ 0.8) = 68.4[𝑚𝑚]
𝑆𝑁1∗ 68.4
−𝐷1 = = = 156[𝑚𝑚]
𝑎1 0.44
𝑫𝟏 = 𝟏𝟔𝟎[𝒎𝒎]

𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁


14.4 + 33.6 + 70.4 > 117[𝑚𝑚]
118.4 > 117[𝑚𝑚] ( 𝑐𝑢𝑚𝑝𝑙𝑒)

4. el CBR de la capa sub-base a 45%, la carpeta asfáltica a 80% y la subrasante a 10%

𝑀𝑟𝑠𝑢𝑏𝑏𝑎𝑠𝑒 = 22.1 ∗ 𝐶𝐵𝑅 0.55 = 22.1 ∗ 450.55 = 179.33[𝑀𝑃𝑎] = 26[𝑘𝑠𝑖]


𝑆𝑁1∗ = 160 ∗ 0.44 = 70.4[𝑚𝑚]
𝑀𝑟𝑠𝑢𝑏𝑟𝑎𝑠𝑎𝑛𝑡𝑒 = 1500 ∗ 10 = 15[𝑘𝑠𝑖]

ING.MARCELO BADANI VILLEGAS 8VO “B”


Carpeta asfáltica
𝑆𝑁1 67
−𝐷1 = = = 153[𝑚𝑚] => 𝐷1∗ = 160[𝑚𝑚]
𝑎1 0.44
−𝑆𝑁1∗ = 160 ∗ 0.44 = 70.4[𝑚𝑚]

Capa base
−𝑆𝑁𝑏𝑎𝑠𝑒 = 3.3"
−𝑆𝑁2 = 3.3" ∗ 2.54 ∗ 10 = 83.82 ≈ 84[𝑚𝑚]
𝑆𝑁2 − 𝑆𝑁1∗ 84 − 70.4
−𝐷2 = = = 122[𝑚𝑚] => 𝐷2∗ = 130[𝑚𝑚]
𝑎2 ∗ 𝑚2 0.14 ∗ 0.8
−𝑆𝑁2∗ = 130 ∗ 0.14 ∗ 0.8 = 14.56[𝑚𝑚]

Capa Sub-base
−𝑆𝑁𝑠𝑢𝑏𝑏𝑎𝑠𝑒 = 3.8"
−𝑆𝑁3 = 3.8" ∗ 2.54 ∗ 10 = 96.52 ≈ 97[𝑚𝑚]
𝑆𝑁3 − (𝑆𝑁1∗ + 𝑆𝑁2∗ ) 97 − (70.4 + 14.56)
−𝐷3 = = = 151[𝑚𝑚] => 𝐷3∗ = 160[𝑚𝑚]
𝑎3 ∗ 𝑚3 0.10 ∗ 0.8
−𝑆𝑁3∗ = 160 ∗ 0.10 ∗ 0.8 = 12.8[𝑚𝑚]

𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁


12.8 + 14.56 + 70.4 > 97[𝑚𝑚]
97.76 > 97[𝑚𝑚] ( 𝑐𝑢𝑚𝑝𝑙𝑒)

Con estos datos, aumentamos el D2 de 130 a 300[mm]

𝑆𝑁2 − 𝑆𝑁1∗ 84 − 𝑆𝑁1∗


−𝐷2 = = = 300[𝑚𝑚]
𝑎2 ∗ 𝑚2 0.14 ∗ 0.8
−𝑆𝑁1∗ = 84 − 300(0.14 ∗ 0.8) = 50.4[𝑚𝑚]
𝑆𝑁1∗ 50.4
−𝐷1 = = = 115[𝑚𝑚] ≈ 120[𝑚𝑚]
𝑎1 0.44

𝑫𝟏 = 𝟏𝟐𝟎[𝒎𝒎]

ING.MARCELO BADANI VILLEGAS 8VO “B”


𝑆𝑁3∗ + 𝑆𝑁2∗ + 𝑆𝑁1∗ > 𝑆𝑁
12.8 + (300 ∗ 0.14 ∗ 0.8) + (120 ∗ 0.44) > 97[𝑚𝑚]
99.2 > 117[𝑚𝑚] ( 𝑐𝑢𝑚𝑝𝑙𝑒)
CONCLUSION

Las opciones 1 y 2 no cumplen con las condiciones necesarias, así que no se consideran. Mientras
que las opciones 3 y 4 cumplen con las condiciones necesarias.
Nosotros elegiríamos la 4 opción ya que se aproxima más al espesor mínimo que es 8[cm]. La
opción 2 tiene el espesor muy alto.
ESAL’s=2000000

ESPESOR USADO 12[cm]


Entonces nuestras capas serian:

12cm

30cm
16cm

ING.MARCELO BADANI VILLEGAS 8VO “B”

También podría gustarte