Está en la página 1de 42

ATN 910&910I&910B&950B Multi-Service Access

Equipment
V200R003C10

Parts Replacement

Issue 02
Date 2014-04-30

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Issue 02 (2014-04-30) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement About This Document

About This Document

Purpose
This document provides guidelines on replacing parts, for ATN device.

The usage precautions are as follows:


l A device can store keys in plaintext, reversible algorithm encryption, or irreversible
algorithm encryption mode. The plaintext mode has the low security level, and the
irreversible algorithm encryption mode has the highest security level. Use different storage
modes for different scenarios. Exercise caution when using an insecure storage mode. The
system automatically selects the irreversible algorithm encryption mode to store local user
keys. Generally, the reversible algorithm encryption mode is used to store protocol keys to
meet interworking requirements.
l If the plaintext mode is used, a password is stored in plaintext in the configuration file. This
results in high security risks. The plaintext mode applies only to scenarios with special
requirements, such as compatibility and interworking requirements.
l Using a password or a key without a change leaves the password prone to being stolen or
cracked, which is more likely in a longer duration. Changing the password on a regular
basis may avoid such incidences, and therefore is recommended.

Related Versions
The following table lists the product versions related to this document.

Product Name Version

l ATN 910 V200R003C10


l ATN 910I
l ATN 910B
l ATN 950B

Intended Audience
The intended audiences of this document are:

Issue 02 (2014-04-30) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement About This Document

l On-site maintenance engineer


l Commissioning engineer
l System maintenance engineer

Symbol Conventions
Symbol Description

Indicates an imminently hazardous situation which, if not


avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not


avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not


avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not


avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to personal
injury.

Calls attention to important information, best practices and


tips.
NOTE is used to address information not related to personal
injury, equipment damage, and environment deterioration.

Command Conventions
Convention Description

Boldface The keywords of a command line are in boldface.

Italic Command arguments are in italics.

[] Items (keywords or arguments) in brackets [ ] are optional.

{ x | y | ... } Optional items are grouped in brackets and separated by


vertical bars. One item is selected.

[ x | y | ... ] Optional items are grouped in brackets and separated by


vertical bars. One item is selected or no item is selected.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement About This Document

Convention Description

{ x | y | ... }* Optional items are grouped in brackets and separated by


vertical bars. A minimum of one item or a maximum of all
items can be selected.

[ x | y | ... ]* Optional items are grouped in brackets and separated by


vertical bars. Several items or no item can be selected.

GUI Conventions
Convention Description

Boldface Buttons, menus, parameters, tabs, window, and dialog titles


are in boldface. For example, click OK.

> Multi-level menus are in boldface and separated by the ">"


signs. For example, choose File > Create > Folder.

Change History
Updates between document issues are cumulative. Therefore, the latest document issue contains
all updates made in previous issues.

Changes in Issue 02 (2014-04-30)


This document has the following updates:

Known bugs are fixed.

Changes in Issue 01 (2014-01-31)


This document is the first release of the V200R003C10 version.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential iv


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement Contents

Contents

About This Document.....................................................................................................................ii


1 Component Information..............................................................................................................1
2 Basic Operation Process and Precautions.................................................................................3
3 Replacing the Chassis...................................................................................................................7
4 Replacing the Control Board of the ATN 910........................................................................10
5 Replacing the Control Board of the ATN 950B......................................................................13
5.1 Replacing the Control Board in 1+1 Protection Mode.................................................................................................14
5.2 Replacing the Control Board without 1+1 Protection Mode........................................................................................16

6 Replacing the PIC Board............................................................................................................19


7 Replacing the PIU Board of the ATN 910...............................................................................22
8 Replacing the PIU Board of the ATN 950B.............................................................................24
9 Replacing the FAN Board..........................................................................................................27
10 Replacing CF Cards...................................................................................................................29
11 Replacing the Optical Module................................................................................................32

Issue 02 (2014-04-30) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 1 Component Information

1 Component Information

Whether ATN Parts Can Be Replaced


Part ATN 910 ATN 910I ATN 910B ATN 950B

Chassis Yes Yes Yes Yes

Control board Yes No No Yes

PIC board Yes No No Yes

PIU board Yes No No Yes

FAN board Yes No No Yes

CF card Yes No No Yes

Optical module Yes Yes Yes Yes


NOTE
All boards and cards on the ATN 910I or ATN 910B cannot be replaced. If a hardware fault occurs, replace
the chassis.

ATN 910 Board Information


Board Board Name

Control board ANC2CXPI/ANC2CXPL

PIC board AND1EG4T/AND1EF8T/AND1EG2/


AND1EG4F/AND1EF8F

AND1ML1/AND1ML1A/AND2ML1A/
AND2ML1B/AND1MD1A/AND1MD1B

AND1AVD8A/AND1AVD8B/
AND1SHD4/AND1SHD4I

PIU board TNC1PIU

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 1 Component Information

Board Board Name

FAN board ANC1FAN


NOTE
Each control board of the ATN 910 has one CF card that can be replaced.

ATN 950B Board Information


Board Board Name

Control board AND1CXPA/AND1CXPB/AND2CXPA/


AND2CXPB/AND2CXPE

PIC board AND1EM4T/AND1EM8T/AND1EM4F/


AND1EM8F/AND1EX1

AND2CQ1B/AND2PQ1

AND1ML1/AND1ML1A/AND3ML1A/
AND3ML1B/AND2MD1A/AND2MD1B

PIU board TND1PIU

FAN board AND1FAN


NOTE
Each control board of the ATN 950B has one CF card, and only the CF card of the AND1CXPA or
AND1CXPB can be replaced.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 2 Basic Operation Process and Precautions

2 Basic Operation Process and Precautions

To ensure that the ATN provides uninterrupted communication services for users, device parts
are replaced when the power is on in most cases. Therefore, to ensure safe operation of a device
and minimize the impact of part replacement on services, maintenance personnel must follow
the basic operation process described in this section.

NOTICE
Huawei engineers need to obtain the telephone number of the GTAC to contact Huawei
headquarters as soon as possible when an exception or a problem that Huawei engineers cannot
locate or solve temporarily occurs.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 2 Basic Operation Process and Precautions

1. Assess the feasibility of the operation.


During the process of troubleshooting or repairing a device, maintenance personnel must
assess whether the operation is feasible before replacing a part.
l Whether the needed spare parts are available in the depot.
l Whether the maintenance personnel is qualified for carrying out the operation.
NOTE
Parts replacement can be carried out only by maintenance personnel who are professionally
trained. Specifically, maintenance personnel must familiarize themselves with the functions of
each part, the basic operation process of part replacement, and the basic skills of part replacement.
l Whether the risks of the operation can be controlled. Part replacement is risky.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 2 Basic Operation Process and Precautions

NOTICE
Improper operation may cause abnormal running of the device, service interruption, or
injuries to the personnel. Therefore, before replacing parts, maintenance personnel must
comprehensively evaluate the risks of the operation and determine whether the risks
can be controlled through certain measures when the power is on. Maintenance
personnel can replace the parts only when the risks can be controlled. Otherwise, contact
Huawei technical support personnel.

2. Prepare tools and spare parts.


After determining that the operation is feasible, maintenance personnel need to prepare
tools and spare parts.
l Prepare spare parts.

NOTICE
To ensure valid part replacement, when replacing the chassis or control board, contact
Huawei engineers to determine whether a license needs to be applied for. For the ATN
910, if the chassis or control board to be replaced is a backup, 1588v2 and L3VPN do
not require a license.For the ATN 910I, if the chassis to be replaced is a backup, 1588v2,
L3VPN, and ports do not require a license.

l The common tools include the multimeter, cable tester, ESD wrist strap, Phillips
screwdriver, flat-head screwdriver, needle-nose pliers, cutter, and pliers.
3. Take protective measures.
Although part replacement is risky, in most cases, however, maintenance personnel can
avoid the risks by taking protective measures.
For example, before replacing a master control board, maintenance personnel can switch
services from the master control board to the slave control board. After the slave control
board runs properly, maintenance personnel can replace the master control board. In this
manner, interruption of services is prevented.
NOTE
Only the ATN 950B with two control boards supports such protective measures.
Therefore, to ensure safe operation of a device and minimize the impact of part replacement
on services, maintenance personnel must take related protective measures.
4. Replace parts.
When the protective measures are available, maintenance personnel can carry out part
replacement according to the procedures in this section.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 2 Basic Operation Process and Precautions

DANGER
Wear an ESD wrist strap or ESD gloves before replacing parts while the power is on.
Avoid direct eye exposure to the laser beam launched from the optical interface board or
fiber.

5. Verify the functions of the new parts.


After completing part replacement, maintenance personnel must verify the functions of the
new parts through the testing methods described in this section.
NOTE
The operation is considered successful only when the new parts are proved to be running normally.
Otherwise, contact Huawei technical support personnel.
6. Return and repair the faulty parts.
If a part that is replaced is faulty, maintenance personnel should fill in the Faulty Card for
Repair, and send the card and the faulty part to Huawei for timely maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 3 Replacing the Chassis

3 Replacing the Chassis

Context
The chassis needs to be replaced in the following situations:
l The chassis of the fixed ATN 910I or ATN 910B is damaged due to a hardware fault or
external forces.
l The chassis of the ATN 910 or ATN 950B on which cards are pluggable is damaged due
to external forces.

Impact on the System


Services will be interrupted for about 30 minutes because the device needs to be powered off to
replace the chassis.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l To ensure valid part replacement, when replacing the chassis, contact Huawei engineers to
determine whether a license needs to be applied for. For the ATN 910, if the chassis to be
replaced is a backup, 1588v2 and L3VPN do not require a license.For the ATN 910I, if the
chassis to be replaced is a backup, 1588v2, L3VPN, and ports do not require a license.
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 3 Replacing the Chassis

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.
Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.
Step 3 For fixed devices, back up the configuration data and mapping between each fiber or cable and
interface on the device. When the part replacement is complete, restore the fiber or cable
connections. For devices on which cards are pluggable, record the slot of each board and mapping
between each fiber or cable and interface on the device. When the part replacement is complete,
restore the fiber or cable connections.
Step 4 Power off the device.

CAUTION
Make sure that indicators on all the boards are off which indicates that the device is powered
off.

Step 5 Remove the power connectors and all fibers and cables connected to the chassis. For devices on
which cards are pluggable, remove all boards.
Step 6 Remove the mounting ears on the chassis and then take down the chassis. (Skip this step if the
chassis is installed on a desk.)

CAUTION
Hold the bottom of the chassis when you remove the mounting ears to prevent injuries to human
bodies or damage to other devices.

Step 7 Remove the mounting ears, and install them onto the spare chassis. Install the spare chassis to
the previous position. Then, restore all boards and fiber or cable connections.
Step 8 Power on the device and observe indicators.
NOTE

l For fixed devices, if the STAT indicator is steady on, the device has been powered on, and software
has been loaded.
l For devices on which cards are pluggable, if the PROG indicator is blinking, the board is being
initialized, and software is being loaded. If the STAT and PROG indicators are steady on, the device
and board have been powered on, and software has been loaded.

Step 9 Log in to the device and run the display device command to query the running status of the
device. If the Status column displays only Normal, the device is running properly.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 3 Replacing the Chassis

ATN 910
ATN910's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
3 PIC Present Registered Normal NA
4 PIC Present Registered Normal NA
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

ATN 910I
ATN 910I DC's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

ATN 910B
ATN910B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

ATN 950B
ATN950B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 PIC Present Registered Normal NA
2 PIC Present Registered Normal NA
7 CXP Present Registered Normal Slave
8 CXP Present NA Normal Master
9 PWR Present Registered Normal NA
10 PWR Present Registered Normal NA
11 FAN Present Registered Normal NA

Step 10 (Optional) Restore the backup data for fixed devices.

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 4 Replacing the Control Board of the ATN 910

4 Replacing the Control Board of the ATN 910

Impact on the System


Services will be interrupted for about 15 minutes when replacing a control board.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l To ensure valid part replacement, when replacing the control board, contact Huawei
engineers to determine whether a license needs to be applied for. If the control board of the
ATN 910 to be replaced is a backup, 1588v2 and L3VPN do not require a license.
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 4 Replacing the Control Board of the ATN 910

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Check the version information of the software package in use. Check whether the software
package file, configuration file, and patch file in use are the same as the startup software package
file, configuration file, and patch file, respectively.
NOTE

l In the user view, run the display version command to check the version information about the software
package in use.
l In the user view, run the display startup command to check the name of the software package file,
configuration file, and patch file.
l Generally, a replacement control board is required to have the same software version. This requirement
is to ensure that the replacement control board can work properly. If a spare control board's version is
later than a control board to be replaced, contact Huawei technical support to determine whether this
spare control board can be used and to obtain replacement guidance.

Step 4 Save the configuration file in use.


NOTE
In the user view, run the save command to save the configuration file to the CF card.

Step 5 Remove the CF card and install it on the new control board. For operation details, see Replacing
CF Cards.

Step 6 Record the slot of the control board and fiber or cable connections of interfaces on the boards.
When the part replacement is complete, restore the fiber or cable connections.

Step 7 Remove cables connected to the board and attach labels onto these cables.

Step 8 Remove the board from the chassis, and insert the new one into the chassis.
NOTE

l During the operation, pull out the part slowly and smoothly to prevent it from colliding with neighboring
boards or interrupting other running parts.
l When removing a part, do not touch the components on it to avoid damages to the part.
1. Unscrew the captive screws anticlockwise with a Phillips screwdriver.
2. Hold the board's ejector levers with both hands and rotate them to the open position with
proper force. When the ejector levers and front panel form a 45-degree angle, the board
will be disconnected from the backplane.
3. Hold the board's ejector levers and pull the board out of the slot along the guide rails. When
the CXPA is half out, hold the lower side of the board and steadily remove the other half.
4. Put the removed part in an ESD bag.
5. Take out the new part from the ESD bag.
6. Hold the ejector levers on the board with both hands, and also hold the lower side. Steadily
and slowly push the board into the slot along the guide. When the board's positioning pin
contacts the chassis's positioning holes, stop pushing the board.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 4 Replacing the Control Board of the ATN 910

7. Rotate the ejector levers to the closed position (the positioning bolts will be in the
positioning holes).
8. Tighten the captive screws clockwise using a Phillips screwdriver to fix the board.
NOTE
If the PROG indicator is blinking, the board is being initialized, and software is being loaded. If the
STAT and PROG indicators are steady on, the board is working properly, and software has been
loaded.

Step 9 Install the optical fibers or cables based on the recorded information and restore the fiber or
cable connections.

Step 10 Log in to the device and run the display device command to query the running status of the new
board. If the Status column displays only Normal, the board is running properly.
ATN910's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
3 PIC Present Registered Normal NA
4 PIC Present Registered Normal NA
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

5 Replacing the Control Board of the ATN


950B

About This Chapter

5.1 Replacing the Control Board in 1+1 Protection Mode

5.2 Replacing the Control Board without 1+1 Protection Mode

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

5.1 Replacing the Control Board in 1+1 Protection Mode


Impact on the System
Replacing the control board in 1+1 protection will not affect services.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l To ensure valid part replacement, when replacing the control board, contact Huawei
engineers to determine whether a license needs to be applied for.
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Check whether the control board to be replaced is the slave control board. If it is the master
control board, perform a master/slave control board switchover.
NOTE

l In the user view, run the display device command to check whether the control board to be replaced
is the slave control board.
l In the system view, run the slave switchover command to perform a master/slave control board
switchover.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

Step 4 Check the version information of the software package in use. Check whether the software
package file, configuration file, and patch file in use are the same as the startup software package
file, configuration file, and patch file, respectively.
NOTE

l In the user view, run the display version command to check the version information about the software
package in use.
l In the user view, run the display startup command to check the name of the software package file,
configuration file, and patch file.
l Generally, a replacement control board is required to have the same software version. This requirement
is to ensure that the replacement control board can work properly. If a spare control board's version is
later than a control board to be replaced, contact Huawei technical support to determine whether this
spare control board can be used and to obtain replacement guidance.

Step 5 Save the configuration file in use.


NOTE
In the user view, run the save command to save the configuration file to the CF card.

Step 6 Remove the CF card and install it on the new control board. For operation details, see Replacing
CF Cards.
NOTE
Skip this step if the CF card of the control board cannot be replaced.

Step 7 Record the slot of the control board and fiber or cable connections of interfaces on the boards.
When the part replacement is complete, restore the fiber or cable connections.

Step 8 Remove cables connected to the board and attach labels onto these cables.

Step 9 Remove the board from the chassis, and insert the new one into the chassis.
NOTE

l During the operation, pull out the part slowly and smoothly to prevent it from colliding with neighboring
boards or interrupting other running parts.
l When removing a part, do not touch the components on it to avoid damages to the part.
1. Unscrew the captive screws anticlockwise with a Phillips screwdriver.
2. Hold the board's ejector levers with both hands and rotate them to the open position with
proper force. When the ejector levers and front panel form a 45-degree angle, the board
will be disconnected from the backplane.
3. Hold the board's ejector levers and pull the board out of the slot along the guide rails. When
the CXPA is half out, hold the lower side of the board and steadily remove the other half.
4. Put the removed part in an ESD bag.
5. Take out the new part from the ESD bag.
6. Hold the ejector levers on the board with both hands, and also hold the lower side. Steadily
and slowly push the board into the slot along the guide. When the board's positioning pin
contacts the chassis's positioning holes, stop pushing the board.
7. Rotate the ejector levers to the closed position (the positioning bolts will be in the
positioning holes).
8. Tighten the captive screws clockwise using a Phillips screwdriver to fix the board.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

NOTE
If the PROG indicator is blinking, the board is being initialized, and software is being loaded. If the
STAT and PROG indicators are steady on, the board is working properly, and software has been
loaded.

Step 10 Install the optical fibers or cables based on the recorded information and restore the fiber or
cable connections.

Step 11 Log in to the device and copy the software package file, configuration file, and patch file saved
in the CF card of the master control board to the CF card of the new slave control board.

Step 12 Run the display device command to query the running status of the new board. If the Status
column displays only Normal, the board is running properly.
ATN950B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 PIC Present Registered Normal NA
2 PIC Present Registered Normal NA
7 CXP Present Registered Normal Slave
8 CXP Present NA Normal Master
9 PWR Present Registered Normal NA
10 PWR Present Registered Normal NA
11 FAN Present Registered Normal NA

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

5.2 Replacing the Control Board without 1+1 Protection


Mode
Impact on the System
Services will be interrupted for about 15 minutes when replacing a control board without 1+1
protection mode.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

NOTICE
l To ensure valid part replacement, when replacing the control board, contact Huawei
engineers to determine whether a license needs to be applied for.
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Check the version information of the software package in use. Check whether the software
package file, configuration file, and patch file in use are the same as the startup software package
file, configuration file, and patch file, respectively.
NOTE

l In the user view, run the display version command to check the version information about the software
package in use.
l In the user view, run the display startup command to check the name of the software package file,
configuration file, and patch file.
l Generally, a replacement control board is required to have the same software version. This requirement
is to ensure that the replacement control board can work properly. If a spare control board's version is
later than a control board to be replaced, contact Huawei technical support to determine whether this
spare control board can be used and to obtain replacement guidance.

Step 4 Save the configuration file in use.


NOTE
In the user view, run the save command to save the configuration file to the CF card.

Step 5 Remove the CF card and install it on the new control board. For operation details, see Replacing
CF Cards.
NOTE
If the CF card of the control board cannot be replaced, copy the software package file, configuration file,
and patch file saved in the CF card of the control board to be replaced to the CF card of the new control
board.

Step 6 Record the slot of the control board and fiber or cable connections of interfaces on the boards.
When the part replacement is complete, restore the fiber or cable connections.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 5 Replacing the Control Board of the ATN 950B

Step 7 Remove cables connected to the board and attach labels onto these cables.

Step 8 Remove the board from the chassis, and insert the new one into the chassis.
NOTE

l During the operation, pull out the part slowly and smoothly to prevent it from colliding with neighboring
boards or interrupting other running parts.
l When removing a part, do not touch the components on it to avoid damages to the part.
1. Unscrew the captive screws anticlockwise with a Phillips screwdriver.
2. Hold the board's ejector levers with both hands and rotate them to the open position with
proper force. When the ejector levers and front panel form a 45-degree angle, the board
will be disconnected from the backplane.
3. Hold the board's ejector levers and pull the board out of the slot along the guide rails. When
the CXPA is half out, hold the lower side of the board and steadily remove the other half.
4. Put the removed part in an ESD bag.
5. Take out the new part from the ESD bag.
6. Hold the ejector levers on the board with both hands, and also hold the lower side. Steadily
and slowly push the board into the slot along the guide. When the board's positioning pin
contacts the chassis's positioning holes, stop pushing the board.
7. Rotate the ejector levers to the closed position (the positioning bolts will be in the
positioning holes).
8. Tighten the captive screws clockwise using a Phillips screwdriver to fix the board.
NOTE
If the PROG indicator is blinking, the board is being initialized, and software is being loaded. If the
STAT and PROG indicators are steady on, the board is working properly, and software has been
loaded.

Step 9 Install the optical fibers or cables based on the recorded information and restore the fiber or
cable connections.

Step 10 Run the display device command to query the running status of the new board. If the Status
column displays only Normal, the board is running properly.
ATN950B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 PIC Present Registered Normal NA
2 PIC Present Registered Normal NA
8 CXP Present NA Normal Master
9 PWR Present Registered Normal NA
10 PWR Present Registered Normal NA
11 FAN Present Registered Normal NA

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 6 Replacing the PIC Board

6 Replacing the PIC Board

Impact on the System


Replacing the PIC board will interrupt services for about three to five minutes.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must be
properly capped to keep dusts away.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 6 Replacing the PIC Board

Step 3 Record the slot of the board and fiber or cable connections of interfaces on the boards. When
the part replacement is complete, restore the fiber or cable connections.
Step 4 Remove cables connected to the board and attach labels onto these cables.

Step 5 Remove the board from the chassis, and insert the new one into the chassis.
NOTE

l During the operation, pull out the part slowly and smoothly to prevent it from colliding with neighboring
boards or interrupting other running parts.
l When removing a part, do not touch the components on it to avoid damages to the part.
1. Unscrew the captive screws anticlockwise with a Phillips screwdriver.
2. Hold the board's ejector levers with both hands and rotate them to the open position with
proper force. When the ejector levers and front panel form a 45-degree angle, the board
will be disconnected from the backplane.
3. Hold the board's ejector levers and pull the board out of the slot along the guide rails. When
the CXPA is half out, hold the lower side of the board and steadily remove the other half.
4. Put the removed part in an ESD bag.
5. Take out the new part from the ESD bag.
6. Hold the ejector levers on the board with both hands, and also hold the lower side. Steadily
and slowly push the board into the slot along the guide. When the board's positioning pin
contacts the chassis's positioning holes, stop pushing the board.
7. Rotate the ejector levers to the closed position (the positioning bolts will be in the
positioning holes).
8. Tighten the captive screws clockwise using a Phillips screwdriver to fix the board.
NOTE
If the PROG indicator is blinking, the board is being initialized, and software is being loaded. If the
STAT and PROG indicators are steady on, the board is working properly, and software has been
loaded.

Step 6 Install the optical fibers or cables based on the recorded information and restore the fiber or
cable connections.
Step 7 Log in to the device and run the display device command to query the running status of the new
board. If the Status column displays only Normal, the board is running properly.
ATN 910
ATN910's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
3 PIC Present Registered Normal NA
4 PIC Present Registered Normal NA
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

ATN 950B
ATN950B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 PIC Present Registered Normal NA
2 PIC Present Registered Normal NA
7 CXP Present Registered Normal Slave
8 CXP Present NA Normal Master

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 6 Replacing the PIC Board

9 PWR Present Registered Normal NA


10 PWR Present Registered Normal NA
11 FAN Present Registered Normal NA

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 7 Replacing the PIU Board of the ATN 910

7 Replacing the PIU Board of the ATN 910

Impact on the System


Services will be interrupted for about 20 minutes because the device needs to be powered off to
replace the PIU board.

Precautions

NOTICE
When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Record the slot of the PIU board.

Step 4 Power off the device.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 7 Replacing the PIU Board of the ATN 910

CAUTION
Make sure that indicators on all the boards are off and the device is powered off.

Step 5 Unscrew the PIU board to be replaced anticlockwise with a Phillips screwdriver and remove the
power cable.

Step 6 Unscrew the PIU board to be replaced anticlockwise from the chassis with a Phillips screwdriver
and remove the PIU board.
NOTE
The chassis may need to be taken down to unscrew the PIU board from the chassis. If the chassis needs to
be taken down, remove the cable connections first.

Step 7 Install the PIU board in the same slot and fix it on the chassis with a Phillips screwdriver.

Step 8 Install the power cable and fix it on the PIU board with a Phillips screwdriver.

Step 9 Power on the device and observe indicators.


NOTE
If the PROG indicator is blinking, the board is being initialized, and software is being loaded. If the STAT
and PROG indicators are steady on, the device and board have been powered on, and software has been
loaded.

Step 10 Log in to the device and run the display device command to query the running status of the new
board. If the Status column displays only Normal, the board is running properly.
ATN910's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 CXP Present NA Normal Master
3 PIC Present Registered Normal NA
4 PIC Present Registered Normal NA
5 PWR Present Registered Normal NA
6 FAN Present Registered Normal NA

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 8 Replacing the PIU Board of the ATN 950B

8 Replacing the PIU Board of the ATN 950B

Impact on the System


Services will not be interrupted if you replace one PIU board because PIU boards work in 1+1
protection mode.

Precautions

NOTICE
When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.

Tool
l ESD wrist strap or ESD gloves
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Record the slot of the PIU board.

Step 4 Press the front of the red latch and properly move the red latch outwards. After the two latches
have been moved outwards, remove the power connectors of the faulty PIU board.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 8 Replacing the PIU Board of the ATN 950B

Step 5 Steadily pull the PIU boar out of the chassis.

Step 6 Push the PIU boar into the slot along the guide rails. Slightly increase force to push the handler
until the FAN is totally inserted in the chassis.

Step 7 Power on the new PIU board.

Step 8 Log in to the device and run the display device command to query the running status of the new
board. If the Status column displays only Normal, the board is running properly.
ATN950B's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 PIC Present Registered Normal NA
2 PIC Present Registered Normal NA
7 CXP Present Registered Normal Slave
8 CXP Present NA Normal Master
9 PWR Present Registered Normal NA
10 PWR Present Registered Normal NA
11 FAN Present Registered Normal NA

----End

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 25


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 8 Replacing the PIU Board of the ATN 950B

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 26


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 9 Replacing the FAN Board

9 Replacing the FAN Board

Impact on the System


If the FAN board has to be replaced, replace it quickly. If the device is operating without a fan,
high temperature may cause a master/slave control board switchover, a system reset, or even a
board burn damage. Under the room temperature (25ºC), replace the FAN board within three
minutes.

Precautions

CAUTION
When removing the FAN board, do not touch the rotating fan leaves.

Tool
l ESD wrist strap or ESD gloves
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.
Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.
Step 3 Record the slot of the FAN board.
Step 4 Hold the handler and tact switch and steadily pull the FAN out of the chassis.
Step 5 Hold the handler and tact switch and push the FAN into the slot along the guide rails. Slightly
increase force to push the handler until the FAN is totally inserted in the chassis and then release
the handler and tact switch.
Step 6 Log in to the device and run the display fan command to query the running status of the new
FAN.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 27


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 9 Replacing the FAN Board

ATN 910
SlotID : 6
Present : YES
Registered: YES
Status : AUTO
FanSpeed : [No.]Speed
: [1] 95%
: [2] 95%
: [3] 95%

ATN 950B
SlotID : 11
Present : YES
Registered: YES
Status : AUTO
FanSpeed : [No.]Speed
: [1] 80%
: [2] 80%
: [3] 80%
: [4] 80%
: [5] 80%
: [6] 80%

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 28


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 10 Replacing CF Cards

10 Replacing CF Cards

Impact on the System


To replace the CF card of a control board, the control board must be removed from the chassis
first. If the control board works in 1+1 protection mode, replacing the CF card will not affect
services; if the control board does not support 1+1 protection mode, services will be interrupted.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l When removing the control board, make sure that the interface is not connected to any fiber
jumpers or cables.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l Phillips screwdriver
l ESD bag

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 29


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 10 Replacing CF Cards

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.

Step 3 Record the slot of the board where the CF card is installed.

Step 4 (Optional) If the control board works in 1+1 protection mode and the control board whose CF
card needs to be replaced is the master control board, run the slave switchover command first
to perform a master/slave control board switchover.

Step 5 For detailed precautions and steps for replacing the control board, see Replacing the Control
Board of the ATN 910, Replacing the Control Board of the ATN 950B with the 1+1
Protection Mode, or Replacing the Control Board of the ATN 950B without the 1+1
Protection Mode.

Step 6 Slowly remove the CF card, and put it in an ESD bag.

Step 7 Insert the new CF card in the designated slot on the control board and push the CF card with a
finger.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 30


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 10 Replacing CF Cards

NOTICE
l Ensure that the CF card is correctly inserted.
l Push the CF card slowly and steadily into the slot. Unsteady operation will cause mis-
alignment between the CF card and pins in the slot, which will in turn cause pin deviation
or damages to the CF card.

Step 8 For detailed precautions and steps for installing the control board on the chassis, see Replacing
the Control Board of the ATN 910, Replacing the Control Board of the ATN 950B with
the 1+1 Protection Mode, or Replacing the Control Board of the ATN 950B without the 1
+1 Protection Mode.

Step 9 Log in to the device and run the dir ? command to see whether the new CF card information is
displayed. If the following information is displayed, the CF card is running.

ATN 910
SlotID : 6
/all List all files
STRING [drive][path][file name]
cfcard: Device name

ATN 950B
SlotID : 11
/all List all files
STRING [drive][path][file name]
cfcard: Device name
slave#cfcard: Device name

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 31


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 11 Replacing the Optical Module

11 Replacing the Optical Module

Impact on the System


If optical modules are not in service protection, replacement of an optical module will cause
service interruption.

Precautions

DANGER
Avoid direct eye exposure to the laser beam launched from the optical interface board or fiber.

NOTICE
l An optical module is an electrostatic sensitive device. Therefore, take ESD measures during
the whole process of replacing an optical module to prevent the optical module from being
damaged.
l Only an external optical module can be replaced. An external optical module is pluggable.
l When replacing a part, make sure that the interface is not connected to any optical fibers or
cables.
l Be careful when you remove or insert an optical cable in case the connector of an optical
cable is damaged.
l Optical interfaces and optical fiber connectors must be clean. Optical fiber connectors must
be properly capped to keep dusts away.

Tool
l ESD wrist strap or ESD gloves
l ESD bag

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 32


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 11 Replacing the Optical Module

Procedure
Step 1 Wear the ESD wrist strap, and insert the grounding end into the ESD jack on the device, or wear
ESD gloves.

Step 2 Make sure that the spare part is the same as the one to be replaced in terms of name, model, and
parameters. If they do not meet the requirements, contact Huawei GTAC.
NOTE
Run the display interface interface-type interface-number or display controller cpos cpos-number
command to view and record the type of the optical module to be replaced, as the following output in bold
displays:
GigabitEthernet0/2/1 current state : DOWN
Line protocol current state : DOWN
Link quality grade : GOOD
Description:HUAWEI, GigabitEthernet0/2/1 Interface
Route Port,The Maximum Transmit Unit is 1500
Internet protocol processing : disabled
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 3e74-2e7c-cf01
The Vendor PN is FTM-9612C-SL10G
The Vendor Name is SOURCEPHOTONICS
Port BW: 1G, Transceiver max BW: 1G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km, Transceiver Type: BiDi
Rx Power: -2.62dBm, Warning range: [-20.00dBm, -3.00dBm]
Tx Power: -5.65dBm, Warning range: [-9.00dBm, -3.00dBm]
Loopback:none, full-duplex mode, negotiation: disable, Pause Flowcontrol:Receive
Enable and Send Disable
Last physical up time : -
Last physical down time : 2013-10-20 08:03:06
Current system time: 2013-10-20 19:28:09
Statistics last cleared:never
Last 300 seconds input rate: 0 bits/sec, 0 packets/sec
Last 300 seconds output rate: 0 bits/sec, 0 packets/sec
Input: 0 bytes, 0 packets
Output: 0 bytes, 0 packets
Input:
Unicast: 0 packets, Multicast: 0 packets
Broadcast: 0 packets, JumboOctets: 0 packets
CRC: 0 packets, Symbol: 0 packets
Overrun: 0 packets, InRangeLength: 0 packets
LongPacket: 0 packets, Jabber: 0 packets, Alignment: 0 packets
Fragment: 0 packets, Undersized Frame: 0 packets
RxPause: 0 packets
Output:
Unicast: 0 packets, Multicast: 0 packets
Broadcast: 0 packets, JumboOctets: 0 packets
Lost: 0 packets, Overflow: 0 packets, Underrun: 0 packets
System: 0 packets, Overruns: 0 packets
TxPause: 0 packets
Input bandwidth utilization : 0%
Output bandwidth utilization : 0%

Step 3 Record the slot and interface of the optical module.

Step 4 Remove fibers.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 33


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 11 Replacing the Optical Module

NOTE
You can remove fibers by hands. If dense fibers are installed, you can use a fiber extractor to remove fibers.
The following figure shows the appearance of a fiber extractor.

1. Clamp the top and bottom sides of an LC/PC connector using hands or a fiber extractor and
press the spring.
2. Remove the fiber connector.
3. Cover the fiber connector with a dust cap.

Step 5 Pull out the optical module to be replaced.

1. Remove the optical cables from the connector and cover the optical cable connector with
a dust cap.
NOTE
If optical interfaces such as CXPI/CXPL/EG4F/EF8F/EM4F/EM8F are concave in the board panel
and difficult to remove by hands, use a fiber extractor to unfold the handle of the optical module and
pull it out.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 34


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 11 Replacing the Optical Module

2. Turn the pulled handle of the optical module downward, as shown in the figure.
3. Hold the handle to pull out the optical module carefully from the optical interface, as shown
in the figure.
4. Place the removed optical module in the ESD bag.

Step 6 Insert the new optical module into the optical interface.

NOTICE
An optical module must not be inserted inversely. If you cannot completely insert an optical
module into the interface, do not push it. Instead, you should reverse it and insert it into the
interface again.

1. Take out the new optical module from the ESD bag and check whether there is any damage
or component missing. Check whether the new optical module is of the same type as the
optical module to be replaced.
2. Insert the new optical module into the optical interface, as shown in the figure. When the
click of the reed in the optical module is heard, the optical module is correctly inserted.
3. Remove the dust cap from the connector and insert the optical cables in the original
sequence.
NOTE
Check whether the LINK indicator on the optical interface works normally. If the indicator is green,
the links connected to the interface are Up.

Step 7 Log in to the device and run the display interface interface-type interface-number or display
controller cpos cpos-number command to view the type and running status of the new optical
module. Check whether the type of the new optical module is the same as that of the original
optical module, as the following output in bold displays:
GigabitEthernet0/2/1 current state : UP
Line protocol current state : UP
Link quality grade : GOOD
Description:HUAWEI, GigabitEthernet0/2/1 Interface
Route Port,The Maximum Transmit Unit is 1500
Internet protocol processing : disabled
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 3e74-2e7c-cf01
The Vendor PN is FTM-9612C-SL10G
The Vendor Name is SOURCEPHOTONICS
Port BW: 1G, Transceiver max BW: 1G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km, Transceiver Type: BiDi
Rx Power: -2.62dBm, Warning range: [-20.00dBm, -3.00dBm]
Tx Power: -5.65dBm, Warning range: [-9.00dBm, -3.00dBm]
Loopback:none, full-duplex mode, negotiation: disable, Pause Flowcontrol:Receive

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 35


Copyright © Huawei Technologies Co., Ltd.
ATN 910&910I&910B&950B Multi-Service Access
Equipment
Parts Replacement 11 Replacing the Optical Module

Enable and Send Disable


Last physical up time : -
Last physical down time : 2013-10-20 08:03:06
Current system time: 2013-10-20 19:35:11
Statistics last cleared:never
Last 300 seconds input rate: 0 bits/sec, 0 packets/sec
Last 300 seconds output rate: 0 bits/sec, 0 packets/sec
Input: 0 bytes, 0 packets
Output: 0 bytes, 0 packets
Input:
Unicast: 0 packets, Multicast: 0 packets
Broadcast: 0 packets, JumboOctets: 0 packets
CRC: 0 packets, Symbol: 0 packets
Overrun: 0 packets, InRangeLength: 0 packets
LongPacket: 0 packets, Jabber: 0 packets, Alignment: 0 packets
Fragment: 0 packets, Undersized Frame: 0 packets
RxPause: 0 packets
Output:
Unicast: 0 packets, Multicast: 0 packets
Broadcast: 0 packets, JumboOctets: 0 packets
Lost: 0 packets, Overflow: 0 packets, Underrun: 0 packets
System: 0 packets, Overruns: 0 packets
TxPause: 0 packets
Input bandwidth utilization : 0%
Output bandwidth utilization : 0%

----End

Follow-up Procedure
After replacing a part, collect the tools. If the part is faulty, maintenance personnel should fill
in the Faulty Card for Repair, and send the card and the faulty part to Huawei for timely
maintenance.

Issue 02 (2014-04-30) Huawei Proprietary and Confidential 36