Type: GRS
Warning
which indicates that death, severe personal injury or substantial
property damage can result if proper precautions are not taken
Caution
which indicates that minor to medium personal injury or property
damage can result if proper precautions are not taken
Caution
2) Handling
Mechanic shocks can remove or damage high sensitive magnetic field coil system, which can cause
dysfunction of equipment.
When transporting and handling, never pass lifting or supporting equipment through the metal
detector aperture.
Tested products should be leaded through detector aperture without physical contact.
Used packaging materials should be free of from metal impurities.
4) Safety instructions
We designed and produced our equipment to be safe. Equipment can be used only in accordance
with manufacturer instructions.
Caution
Caution
Caution
Caution
There shall be included a switch or circuit breaker in the building installation. It shall
be marked as the disconnecting device for the equipment and should meet the
requirements of the IEC60947 standard.
The switch or circuit breaker should be near the equipment.
Electric Arc Welding is not allowed on the line where incorporated metal detector on the basic metal
construction is!
Max length of connecting cable for self-depended control unit is 10m.
Metal Detector should not be placed close to any source of emitted electromagnetic interference.
7) Measurement cable
This is an antennal cable that connects the sensor system of metal detector with electronic control
unit in box if it is self-depended (separated) from metal detector.
Cables should be placed into protective iron pipes and should be dislocated from high power cables.
Max. length of cable is 10m.
CABLE-CONECTION
Metal detector have to be connected via shielded cables. The shielding must be
grounded on the supplying side only.
METAL-FREE ZONE
The size of the metal-free zone is determined by the type and size of the sensor's aperture. Metal-free zone
is used to determine the distance between the detector and any metal objects. This is especially true for
metal parts that are moving or vibrating. If a proper size of a metal-free zone can not be achieved the
detectors' sensitivity has to be reduced in order to avoid false detections. Electrical wires, motors with
fluctuating magnetic field and other factors that can alter a magnetic field can also have impact on the metal-
free zone even if they are installed beyond its border.
MATERIALS
Magnetic materials (especially magnetic steel) usually have greater influence on a magnetic field than
nonmagnetic materials (austenite steel, aluminum and others). In other words nonmagnetic metal materials
usually cause less disturbances compared to the magnetic ones and can therefore be installed somewhat
closer to the sensor if necessary. Nonmetal materials and electrical insulators naturally have no effect on the
sensor.
VIBRATIONS
The conveyor system must not cause any pronounced vibrations that could be transferred to the sensor. It
can be very helpful if the sensor has separate construction. The feet of the detector must be firmly anchored
to the ground in order to prevent movement. The sensor is mounted on shock absorbers. Shock absorbers
damp mechanical vibrations, provide electrical isolation and prevent distortion of the senor itself. Conveyor
belt, the products that are being tested and running boards must pass through the sensor without touching it.
WARNING!
Electric Arc Welding is not allowed on the line where incorporated metal detector on the basic metal
construction is!!!
1) Metal detector is connected to main power source line, so when you turn it on the Metal Detector is
automaticlaly turned on too (Metal detector is in operation mode). Check if indicators L1 and L10
(Operation) are on.
2) Metal detector is turned on and ready to operate and we can turn on the transport system.
1) Device is working undisturbed until metal fragment comes into metal free zone. Then electronic
system reacts automatically and start alarming process (A1 signal or extra exterior acoustic or optical
alarm – as option), stopping the transporting system or starting the rejecting mechanism, depends on
type.
2) In metal free zone find the metal fragment and remove it. Press RESET key to reactivate detector. Exception is
detector with automatic rejection.
3)
TECHNICAL DATA
ATENTION!!!
*Do not connect any power on potencially free contacts no.: 4 and 5, because electronic modul can be
damaged!
DRAGO ELECTRONICA
TYPE GRS-600x300
1.1 Keys
There are 3 keys on the keyboard:
»UP« - key for moving through menu and key for increasing values. We can reach bigger step by increasing
at some values, if we hold the key for longer time. »DOWN« - key for moving through menu and key for
decreasing values. We can reach bigger step by decreasing at some values, if we hold the key for longer
time.
»SELECT-OK« - with that key we activate changing of the value and confirming the value. We can clean
number of detections, if we hold the key for longer time
(5 seconds).
1.2 Menus
There are two modes of menus in electronics: user (limited) and administrator. Which functions will be
enabled is defined exclusively in program when electronics is programmed. We have to switch on the jumper
»ADMIN« on the board of electronics to change in the administrator mode. Electronics is in user mode when
the jumper is switched off.
Sensitivity @ Sensitivity @
Sel-OK D:12(3) or ||||||||| 67%
Upper line: momentarily value. Electronics is in administrator mode if there is »@« in the upper right angle.
Lower line: - working mode (LED »START« is on – first picture). Display shows
»Sel-OK«, beside that inscription there is number of detections (in the
brackets – number of detections after reset)
- setting mode (LED »START« is off – second picture). Current value.
2 Settings
Settings are:
"Sensitivity" – entry amplification of signal from detector
"Frequency" - frequency in [Hz]. If we hold key for 3 seconds, step increases for 10 times
"Detection time"* - time in which first and second oscillation response execute
2.1.3Setting phase
Phase is important part in detection of different materials, because they give different response by different
phase when they convey through detector. We can set phase with 1° step from 0° to 180° . We have to be
cautious, because each detector has its own optimal phase.
2.1.7 Beep
When the impulse of relay 1 is set on 0ms (after detection stays set) beep sounds equally (PPPP). If in the
meantime there come to another detection, the sound of beep changes.
2 beeps of sound and 2 beeps of pause (PP__PP__PP).
X 300 400 500 650 800 1000 1200 1400 1600 1800 2000
A 890 990 1090 1240 1390 1590 1790 1990 2190 2390 2590
B 500 600 700 850 1000 1200 1400 1600 1800 2000 2200
C od 300 do 800 mm po 50 mm
D 640 740 840 990 1140 1340 1540 1740 1940 2140 2340
E 400 400 400 400 500 500 500 600 600 700 700
Connection clamps
1 Operating voltage 220V ±10% 50Hz
2 Off switch
3 Contact rating Umax=250V Imax=3A 100VA
4 Signal lamp or horn 220V 50Hz
5 Detection contact rating Umax=250V Imax=3A 100VA
TYPE GRS-600x300
DRAGO ELECTRONICA
MODELO GRS-600x300
A. TRISTANY COMAS S. L., under its own responsibility, declares that the:
MODEL: GRS-600x300
Has been manufactured, and is found to be, in compliance with Directive 2006/42/CEE,
as well as with R.D. 1435 /1992, and that consequently the product has been marked with
the anagram
Drago Electronica. gives 24 months guarantee on referred product and it obligates to:
• repair all breakdowns and remove all technical failures that would appear at normal and
regulated usage of product.
• repair product in period of 10 days. If repair would last more than 10 days, the guarantee
time of product extends for time that product was not functional.
• if found out that breakdown has been caused by mechanical force or incorrect usage of
product
• if unauthorized person has made reparation, used unsuitable spare parts and has caused
breakdown with his intervention.
• if producer’s work instructions with product/device were ignored (not considered)