CONTROL ANTIINCRUSTANTE

ABRIL - 2010
AGUA A MERRIL CROWE AGUA A MOLINOS AGUA A SELLOS DE BOMBAS
Antincrus. flujo Dosif. Volumen Antincrus. flujo Dosif. Volumen Antincrus. flujo Dosif. Volumen
Fecha
m3/h m3/h ppm Ant. ( L ) m3/h m3/h ppm Ant. ( L ) m3/h m3/h ppm Ant. ( L )
2 0.0205 750.0 29.0 850 0.01000 220 48.3 900 0.00000 100 0.0 0
5 0.0219 750.0 31.0 760 0.01210 180 71.4 820 0.00000 110 0.0 0
8 0.0210 750.0 29.7 690 0.01120 190 62.6 750 0.00150 80 19.9 340
10 0.0220 750.0 31.2 630 0.01210 210 61.2 680 0.00140 110 13.5 250
12 0.0240 650.0 39.2 500 0.01100 200 58.4 550 0.00110 120 9.7 150
16 0.0210 600.0 37.2 100 0.01400 220 67.6 450 0.00150 100 15.9 120
19 0.0250 750.0 35.4 880 0.01000 190 55.9 350 0.00170 80 22.6 90
22 0.0254 750.0 36.0 550 0.00900 210 45.5 350 0.00220 120 19.5 70
26 0.0224 750.0 31.7 350 0.00700 200 37.2 200 0.00185 90 21.8 60
29 0.0244 750.0 34.6 200 0.00650 180 38.4 120 0.00165 100 17.6 50
33.5 , 54.6 17.6
AGUA A MERRIL CROWE AGUA A MOLINOS AGUA A SELLOS DE BOMBAS
Antiincrustante 2,8- 3,2 cc/seg 2 - 2,5 cc/seg 0,5 - 1 cc / seg
Este aforo permitira mantener la dosifiacacion en ppm, recomendado, para evitar las incrustaciones en las tuberias.
D o sificacio n (p p m )

Control Antiincrustante
80.0

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Abril - 2010
AGUA A MERRIL CROWE AGUA A MOLINOS AGUA A SELLOS DE BOMBAS

Miguel Angel Leytón


Supervisor Metalurgista.
OBSERVACIONES
Se tiene que incrementar antiincrustante al tanque dosificador de la linea de agua de sello.

Miguel A. Leyton L.
METALURGISTA