VARIABLE
DISPLACEMENT
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
IP Videoconferencing
E-mail: info@casappa.com
www.casappa.com
MVP
INDEX
Section Page
FEATURES ......................................................................................................................... 3
DISPLACEMENT SETTING
CENTER OF GRAVITY ............................................................................................................ 8
REGULATORS ................................................................................................................... 40
2 ID02 DCAT048-002
MVP
FEATURES
Variable displacement axial piston pumps swash plate design ideally suited for medium and high pressure open circuit
applications. The compact design allows to be mounted directly on engine motors.
Replaces: 03/06.2011
1 Pump body
2 Swash plate
3 Cylinders block
4 Counterbalancing spring
5 Plug
6 Max. displacement limiter
7 Cover
8 Valve plate
9 Min. displacement limiter
10 Piston
O 05/10.2014
DCAT048-002 ID02 3
MVP
Replaces: 03/06.2011
fire resistant fluids and biodegradable fluids according to the ling, gate valves, etc.) to a minimum. A length of flexible tubing
technical data shown in the tables on pages 5 ÷ 7. The system is recommended to reduce the transmission of vibrations.
should be designed to prevent aeration of the hydraulic fluid. Before connecting the lines, remove any plug and make sure
that the lines are perfectly clean. Check that the drain line is
FLUID VISCOSITY
dimensioned in a way to guarantee a case pressure lower than
The fluid viscosity range for optimal use of MVP pump is betwe- 1,5 bar (22 psi) absolute. The drain line must be connected
en 15 and 35 cSt (77 and 163 SSU). directly (no filter, no valves, no oil cooler) to the tank and must
Functional limit conditions are: terminate below the oil level. Check that the dimensions of the
max.: 1500 cSt (6818 SSU) at start up at minimum temperature suction line guarantee a pressure equal or superior to 0,8 bar
of -25 °C (-13 °F) with straight and short inlet line. (24 in Hg). Inlet pressure less than 0,8 bar (24 in Hg) could
min.: 10 cSt (58 SSU) at maximum temperature of 110 °C cause an increase of noise emission, the decrease of the pump
(230 °F) performances and a reduction of its life expectancy.
FILTRATION STARTING UP
To ensure the optimal performance and the maximum life to the Check that all connections are secure and that the entire sy-
pump, the hydraulic fluid must have and maintain a fluid conta- stem is completely clean. Add oil to the tank always using a
mination within the values shown in the table below. filter. Bleed the air from the circuit to help the filling. Turn on the
system for a few moments at minimum speed, then bleed the
Working pressure Δp < 140 140 < Δp < 210 Δp > 210 circuit again and check the level of oil in the tank. Gradually
bar (psi) (2030) (2030) (3045) (3045) increase the pressure and speed of rotation up to the pre-set
Contamination operating levels, which must stay within the stated limits as
9 8 7 specified in the catalogue.
class NAS 1638
Contamination
class ISO 20/18/15 19/17/14 18/16/13 FOR VERY LOW TEMPERATURE
4406:1999
Achieved with filter STARTING UP
ßx(c) ≥75 according 10 μm 10 μm 10 μm We strongly recommend to warm up the oil before running the
to ISO 16889 machine. If this is not possible, the warm up of the oil and of the
pump should be carried out following these instructions:
• Start the pump in stand-by condition at minimum speed.
Casappa recommends to use its own Keep this working condition until the pump case reaches
production filters: -20°C (-4°F)
• Increase slowly the displacement.
Max pressure permitted: 50 bar (725 psi). The maximum
permitted speed is strictly connected to the layout of the inlet
circuit; check that there is no cavitation before increasing the
speed.
STORAGE O • Keep this working condition until the oil temperature in the
The storage must be in a dry environment. whole system is -10°C (14°F).
Max storage time in ideal conditions is 24 months. • Maximum pressure can be achieved from now on.
O 05/10.2014
The ideal storage temperature is between 5°C (41°F) and 20°C • Always check the outlet flow to prevent cavitation damage.
(68°F). No problem in case of temperature between -40°C
(-40°F) and 50°C (122°F). Below -40°C (-40°F) please consult All the temperature are referred to oil with viscosity ISO VG 32
our technical sales department. according to DIN 51 519.
INSTALLATION SUGGESTIONS
Check that the maximum coupling eccentricity stays within 0,25 To prevent cavitation at low temperature we suggest:
mm (0.0098 in) to reduce shaft loads due to misalignment. It is • To warm up the tank
advised to use a flexible coupling suitable to absorb eventual • To pressurize the tank
rotational shocks. For applications with axial and radial loads • To oversize the inlet hose
exceeding published standards, consult our sales department.
The direction of rotation of the pump must agree with the prime
mover rotation. Before installation, the case of the pump must
be filled with fluid.
4 ID02 DCAT048-002
MVP
MOUNTING POSITIONS
Minimum oil level equal or above Minimum oil level equal or above
the pump mounting face. the pump mounting face.
Minimum oil level below the pump Minimum oil level below the pump
mounting face. mounting face.
Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
(24 in Hg) (24 in Hg)
B ≤ 800 mm (31.4961 in) B ≤ 800 mm (31.4961 in)
C = 200 mm (7.874 in) C = 200 mm (7.874 in)
Arrangement outside the tank above Arrangement outside the tank above
oil level. oil level.
Min. inlet pressure= 0,8 bar abs Min. inlet pressure= 0,8 bar abs
03/06.2011
IN= inlet line - D1= drain line - A= min. distance between the line - B+C= permissible suction height - C= line immersion depth
DCAT048-002 ID02 5
MVP
28 30 34
Max. displacement (1.71) (1.83) (2.07)
3
cm /rev (in /rev) 3 14 45 53 65 72 84
(0.85) (2.75) (3.23) (3.97) (4.39) (5.12)
MVPD 30
MVP 30
Pump series
MVPD 48
MVP 48
MVP 60
Working pressure p1 - p3 p1 - p3 p1 - p3
bar (psi)
230 290 280 350 250 315
- - -
(3335) (4205) (4060) (5075) (3625) (4568)
PRESSURE DEFINITION
O
p1 Continuous pressure
p2 Intermittent pressure
O 05/10.2014
p3 Peak pressure
6 ID02 DCAT048-001
MVP
TECHNICAL DATA
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Max. displacement 3
cm /rev 28 34,8 45 53,7 60 72 84,7
(theor.) Vmax (in3/rev) (1.71) (2.12) (2.75) (3.28) (3.66) (4.39) (5.17)
bar abs. 0.8
min.
(in Hg) (24)
Inlet pressure
bar abs. 25
max.
(psi) (363)
280 250 280 250 280 280 250
continuous
(4060) (3625) (4060) (3625) (4060) (4060) (3625)
Max. outlet bar 315 280 315 280 315 315 280
intermittent
pressure pmax (psi) (4568) (4060) (4568) (4060) (4568) (4568) (4060)
350 315 350 315 350 350 315
peak
(5075) (4568) (5075) (4568) (5075) (5075) (4568)
Max. drain line bar abs. 2
O
pressure (psi) (29)
Max. speed nmax min-1 @ Vmax (1) 3500 2900 3000 2500 3000 2700 2500 O
98 101 135 134 180 194 212
@ nmax
(25.9) (26.7) (35.7) (35.4) (47.6) (51.3) (56.0) O
Max. delivery l/min 56 70 90 107 120 144 169
@ 2000 min-1
(theor.) (US gpm) (14.8) (18.5) (23.8) (28.3) (31.7) (38.0) (44.7)
42 52 68 81 90 108 127
@ 1500 min-1
(11.1) (13.7) (18.0) (21.4) (23.8) (28.5) (33.6)
45,7 42,1 63 55,9 84 90,7 88,2
@ nmax
(61.2) (56.4) (84.4) (74.9) (112.6) (121.5) (118.2) O
Max. power
kW 26,1 29 42 44,8 56 67,2 70,6
(theor.) (HP)
@ 2000 min-1
(35.0) (38.9) (56.3) (60.0) (75.0) (90.0) (94.6)
(Δp = pmax cont.)
19,6 21,8 31,5 33,6 42 50,4 52,9
@ 1500 min-1
(26.3) (29.2) (42.2) (45.0) (56.3) (67.5) (70.9)
124,8 138,5 200,5 213,7 267,4 320,9 337
@ pmax cont.
Max. torque Nm (1105) (1226) (1775) (1891) (2367) (2840) (2983)
(theor.) (lbf in) @ 100 bar 44,6 55,4 71,6 85,5 95,5 114,6 134,8
(1450 psi) (395) (490) (634) (757) (845) (1014) (1193)
kgm2 0,002 0,002 0,003 0,003 0,008 0,008 0,008
Moment of inertia (ft2 lbs) (0.05) (0.05) (0.07) (0.07) (0.19) (0.19) (0.19)
l 0,85 0,85 1 1 1,3 1,3 1,3
Fill volume (US gallons) (0.22) (0.22) (0.26) (0.26 ) (0.34) (0.34) (0.34)
O 05/10.2014
kg 15 15 19 19 22 22 22
Mass (approx.) (lbs) (33.1) (33.1) (41.9) (41.9) (48.5) (48.5) (48.5)
Seals N= Buna V= Viton
-25 -15
min.
(-13) (5) O
Operating °C 80 110
max. cont.
temperature (°F) (176) (230)
100 125
max. peak
(212) (257)
(1) = with an inlet pressure of 1 bar abs (14.5 psi) and viscosity between 15 and 35 cSt (77 and 163 SSU). O
Reducing the displacement or increasing the inlet pressure the max. speed changes. See table at page 10.
For different working conditions, please consult our technical sales department.
DCAT048-002 ID02 7
MVP
TECHNICAL DATA
Replaces: 03/06.2011
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
continuous 140 (2030)
Max. outlet
bar (psi) intermittent 150 (2175)
pressure pmax
peak 160 (2320)
Max. speed nmax min-1 @ Vmax (1) 2200 1800 2000 1700 2000 1700 1500
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 55 (131)
Bearing life
% 20 %
(ref. mineral oil)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
continuous 160 (2320)
Max. outlet
bar (psi) intermittent 170 (2465)
pressure pmax
peak 180 (2610)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. 2 (36)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)
O 05/10.2014
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
continuous 180 (2610)
Max. outlet
bar (psi) intermittent 195 (2828)
pressure pmax
peak 210 (3045)
Max. speed nmax min -1
@ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 40 %
(ref. mineral oil)
8 ID02 DCAT048-001
MVP
TECHNICAL DATA
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Replaces: 03/06.2011
HETG - Natural based fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
continuous 180 (2610)
Max. outlet
bar (psi) intermittent 195 (2828)
pressure pmax
peak 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals N= Buna
Operating min. -10 (14)
°C (°F)
temperature max. 60 (140)
Bearing life
% 50 %
(ref. mineral oil)
HEPG - Polyglycol based synthetic fluid (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
continuous 180 (2610)
Max. outlet
bar (psi) intermittent 195 (2828)
pressure pmax
peak 210 (3045)
Max. speed nmax min-1 @ Vmax (1) 2350 1900 2150 1800 2150 1800 1600
Seals V= Viton
O 05/10.2014
HEES - Synthetic esters (the water content must never exceed 0,1 %)
Pump type MVP 30·28 30·34 48·45 48·53 60·60 60·72 60·84
Seals V= Viton
Operating min. -15 (5)
°C (°F)
temperature max. 80 (176)
Bearing life
% 100 %
(ref. mineral oil)
DCAT048-001 ID02 9
MVP
TECHNICAL DATA
% Variation of the max. speed in relation of the inlet pressure and/or displacement reduction
Inlet
Displacement %
pressure
psi (bar abs) 65 70 80 90 100
03/06.2011
Example 1 Example 2
Displacement: 100 % Displacement: 80 %
Speed: 100 % Inlet pressure: 1,0 bar abs. (14.5 psi)
Inlet pressure: 1,0 bar abs. (14.5 psi) Speed: 115 %
10 ID02 DCAT048-001
MVP
DISPLACEMENT SETTING
Replaces: 03/06.2011
For different setting ranges, please consult our technical sales department.
CENTER OF GRAVITY
Center of gravity
DCAT048-001 ID02 11
MVP
PORTS POSITION
Anti-clock rotation
Clockwise rotation
03/06.2011
12 ID02 DCAT048-002
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3500 min-1
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-002 ID02 13
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2900 min-1
!"#
$
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
14 ID02 DCAT048-001
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3000 min-1
! $!
$
$! #!"
!$ "!
! $!
"
! !
!# !
! !"
! !
$ $ #
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-001 ID02 15
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2500 min-1
# !#
!
!# #$
"
#! $#
"# "!#
$
# #"
"
# #
#" "#$
# #
! ! "
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
16 ID02 DCAT048-001
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 3000 min-1
! !
"
! #!
"
!# !
! !"
!" "!
# # $ "
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-001 ID02 17
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2700 min-1
! !"
#
#! !
"
! !
! $!
"
#!$ !
! !
! !
" " #
03/06.2011
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
18 ID02 DCAT048-001
MVP
Each curve has been obtained at 50 °C (122 °F), using oil with viscosity 46 cSt (210 SSU) at 40 °C (104 °F) and at
these speed: (1) 1500 min-1
(2) 2000 min-1
(3) 2500 min-1 O
Replaces: 03/06.2011
""# "!#
#$ #
!
#" #
"# "!#
# #
! ! "
O 05/10.2014
Values shown in the diagrams are indicative only. Actual values may vary depending on the pump configuration.
DCAT048-001 ID02 19
MVP
03/06.2011
20 ID02 DCAT048-002
MVP
Anti-clockwise rotation
03/06.2011
DCAT048-002 ID02 21
MVP
IN OUT D1
MVP MVP KP20 Drain
1” 1/4 3/4” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump KAPPA (for more information, please consult our technical sales department)
Pump
type
20•4 20•6,3 20•8 20•11,2 20•14 20•16 20•20 Dimensions
22 ID02 DCAT048-002
MVP
IN OUT D1
MVP MVP PHP20
Drain
1” 1/4 3/4” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump POLARIS PH (for more information, please consult our technical sales department)
Pump
type
20•19 20•20 20•23 20•24,5 20•25 20•27,8 20•31,5 Dimensions
DCAT048-002 ID02 23
MVP
03/06.2011
24 ID02 DCAT048-002
MVP
Anti-clockwise rotation
03/06.2011
DCAT048-002 ID02 25
MVP
IN OUT D1
MVP MVP KP20 Drain
1” 1/2 1” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump KAPPA (for more information, please consult our technical sales department)
Pump
type
20•4 20•6,3 20•8 20•11,2 20•14 20•16 20•20 Dimensions
26 ID02 DCAT048-002
MVP
IN OUT D1
MVP MVP PHP20 Drain
1” 1/2 1” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump POLARIS PH (for more information, please consult our technical sales department)
Pump
type
20•19 20•20 20•23 20•24,5 20•25 20•27,8 20•31,5 Dimensions
DCAT048-002 ID02 27
MVP
03/06.2011
28 ID02 DCAT048-002
MVP
Anti-clockwise rotation
03/06.2011
DCAT048-002 ID02 29
MVP
IN OUT D1
MVP MVP KP20
Drain
2” 1” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump KAPPA (for more information, please consult our technical sales department)
Pump
type
20•4 20•6,3 20•8 20•11,2 20•14 20•16 20•20 Dimensions
30 ID02 DCAT048-002
MVP
IN OUT D1
MVP MVP PHP20 Drain
2” 1” 1/2” port
Dimensions at page 38 ÷ 39
Gear pump POLARIS PH (for more information, please consult our technical sales department)
Pump
type
20•19 20•20 20•23 20•24,5 20•25 20•27,8 20•31,5 Dimensions
DCAT048-002 ID02 31
MVP
Replaces: 03/06.2011
Ext. Involute Spline ANSI B92.1
with major diameter modified
O 13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Ext. Involute Spline ANSI B92.1
with major diameter modified
13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5
O 05/10.2014
32 ID02 DCAT048-002
MVP
O
Ext. Involute Spline ANSI B92.1
with major diameter modified
13 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5
For different drive shafts, please consult our technical
O department.
DCAT048-002 ID02 33
MVP
Replaces: 03/06.2011
Ext. Involute Spline ANSI B92.1 Ext. Involute Spline ANSI B92.1
O with major diameter modified with major diameter modified
15 teeth - 16/32 Pitch - 30 deg 15 teeth - 16/32 Pitch - 30 deg
Flat root - Side fit - Class 5 Flat root - Side fit - Class 5
34 ID02 DCAT048-002
MVP
O
O 05/10.2014
DCAT048-002 ID02 35
MVP
x x x
O 05/10.2014
MVP 30
MVP 48 x x x x x
MVP 60 x x x x x
X Available combination
36 ID02 DCAT048-002
MVP
x x x x x x x x x x
O 05/10.2014
MVP 60 MVP 60
DCAT048-002 ID02 37
MVP
PORTS SIZES
(z) Available only with inlet and outlet ports type Split SSS and SAE ODT.
Tightening torque for high pressure side port [values obtained at 350 bar (5075 psi)]
SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSM
Metric thread ISO 60° conforms to ISO/R 262
Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 M 10 45 +2,5
MB 3/4”
(0.7874) (1.8740) (0.8740) 17 (0.6693)
—
(398 ÷ 420)
25,4 52,4 26,2 M 10 30 +2,5
MC 1”
(1.0000) (2.0630) (1.0315) 17 (0.6693)
—
(266 ÷ 288)
32 58,7 30,2 M 10 20 +1
MD 1” 1/4
(1.2598) (2.3110) (1.1890) 17 (0.6693) (177 ÷ 186)
—
SAE FLANGED PORTS J518 - Standard pressure series 3000 psi - Code 61 SSS
American straight thread UNC-UNF 60° conforms to ANSI B 1.1
03/06.2011
Nominal
A B C D
CODE
size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
20 47,6 22,2 3/8 - 16 UNC-2B 30 +2,5
SB 3/4”
(0.7874) (1.8740) (0.8740) 17 (0.6693)
—
(266 ÷ 288)
25,4 52,4 26,2 3/8 - 16 UNC-2B 35 +2,5
SC 1”
(1.0000) (2.0630) (1.0315) 17 (0.6693)
—
(310 ÷ 332)
32 58,7 30,2 7/16 - 14 UNC-2B 25 +1
SD 1” 1/4
(1.2598) (2.3110) (1.1890) 17 (0.6693) (221 ÷ 230)
—
38 ID02 DCAT048-002
MVP
PORTS SIZES
Tightening torque for high pressure side port [values obtained at 350 bar (5075 psi)]
Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
9,5 12 +1
03 (X) 1/4” 7/16” - 20 UNF - 2B —
(0.3740)
— — —
(106 ÷ 115)
33 17, 1 20 +1
OB (z) 1/2” 3/4” - 16 UNF - 2B
(1.2992) (1.3780)
—
(0.0394 (177 ÷ 186)
35 20,5 2 30 +2,5
OC (z) (1.3780) (0.8071)
—
(0.0787 (266 ÷ 288)
—
5/8” 7/8” - 14 UNF - 2B
34 20,5 17 0,5 70 +5
OC () (1.3386) (0.8071) (0.6693) (0.0197)
—
(620 ÷ 664)
30,5 20 170 +10
OF 1” 1 5/16” - 12 UNF - 2B —
(1.2008) (0.7874)
— —
(1505 ÷ 1593)
45 20 100 +5
OH 1” 1/2 1 7/8” - 12 UNF - 2B —
(1.7717) (0.7874)
—
(885 ÷ 929)
—
Nominal
A ØB ØC D E
CODE
size mm mm mm mm mm Nm Nm
(in) (in) (in) (in) (in) (lbf in) (lbf in)
8,75 12 5 +0,25
GA (X) 1/8” G 1/8 —
(0.3444) (0.4724)
— —
(44 ÷ 46)
30 19 17 2 20 +1
GD (z) (1.1811) (0.7480) (0.6693) (0.0787 (177 ÷ 186)
—
1/2” G 1/2
19 17 50 +2,5
GD () —
(0.7480) (0.6693)
— —
(443 ÷ 465)
DCAT048-002 ID02 39
MVP
Replaces: 03/06.2011
O
Pressure setting Standard
Compensator Pump range setting
type type
bar (psi) bar (psi)
80 ÷ 280 280
MVP 30·28 (1160 ÷ 4060) (4060)
80 ÷ 250 250
MVP 30·34 (1160 ÷ 3625) (3625)
80 ÷ 280 280
MVP 48·45 (1160 ÷ 4060) (4060)
80 ÷ 250 250
RP0 MVP 48·53 (1160 ÷ 3625) (3625)
80 ÷ 280 280 Z Option
MVP 60·60 (1160 ÷ 4060) (4060) O
80 ÷ 280 280
MVP 60·72 (1160 ÷ 4060) (4060)
MVP 60·84
80 ÷ 250 250 Z OPTION
(1160 ÷ 3625) (3625)
Damping restrictor for critical applications.
In case of system instability or pressure oscillations, the addi-
tional damping restrictor slows down the pump control system,
damping the regulation transients.
OPERATING CURVES The pump recovery time increases.
The use of the damping restrictor must be evaluated and ap-
Curves have been obtained at the speed of 1500 min-1 and oil proved by Casappa technical sales department for the specific
temperature 50 °C (122 °F). application.
REMOTE CONTROL
For remote pressure compensator LS3 see page 50.
O 05/10.2014
t1 t2
Pump Response time [ms] Recovery time [ms]
type (off stroke) (on stroke)
MVP 30 46 150
MVP 48 48 150
MVP 60 50 150
40 ID02 DCAT048-002
MVP
O
A B C
Pump
type mm mm mm
(in) (in) (in)
203 39 101
MVP 30
(7.9921) (1.5354) (3.9764)
222 44 107
MVP 48
(8.7402) (1.7323) (4.2126)
227 44 107
MVP 60
(8.9370) (1.7323) (4.2126)
DCAT048-002 ID02 41
MVP
Replaces: 04/01.2012
Z Option
OPERATING CURVES O (See page 40 for more information)
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F).
O 05/10.2014
Z Option
O (See page 40 for more information)
42 ID02 DCAT048-002
MVP
O
A B C D E
Pump
type mm mm mm mm mm
(in) (in) (in) (in) (in)
203 171 86 89,5 137
MVP 30
(7.9921) (6.7323) (3.3858) (3.5236) (5.3937)
222,5 190 92,5 94,5 143,5
MVP 48
(8.7598) (7.4803) (3.6417) (3.7205) (5.6496)
227,5 195,6 92,5 94,5 143,5
MVP 60
(8.9567) (7.7008) (3.6417) (3.7205) (5.6496)
DCAT048-002 ID02 43
MVP
Replaces: 04/01.2012
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F). O
Z Option
(See page 40 for more information)
RP2 - LS2 (with flow control)
Not included
in supply
O
VALVE FEATURES
Valve
Arrangement Volt
code
O 05/10.2014
44 ID02 DCAT048-002
MVP
O
A B C D E F G H I
Pump
type mm mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in) (in)
204 131 89 122 166 98 132 107 137
MVP 30
(8.0315) (5.1575) (3.5039) (4.8031) (6.5354) (3.8583) (5.1969) (4.2126) (5.3937)
223 151 95 128,5 172,8 103 137 113 143,5
MVP 48
(8.7795) (5.9449) (3.7402) (5.0591) (6.8031) (4.0551) (5.3937) (4.4488) (5.6496)
228,6 156 95 128,5 172,8 103 137 113 143,5
MVP 60
(9.0000) (6.1417) (3.7402) (5.0591) (6.8031) (4.0551) (5.3937) (4.4488) (5.6496)
DCAT048-002 ID02 45
MVP
Replaces: 03/06.2011
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F).
Normally Normally
closed open
O
Not included
Valve
Arrangement Volt in supply
code
1 Normally closed 12 VDC
2 Normally closed 24 VDC
46 ID02 DCAT048-002
MVP
O
A B C D E F
Pump
type mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in)
232 132 86 127 61 144
MVP 30
(9.1339) (5.1969) (3.3858) (5.0000) (2.4016) (5.6693)
251 151 92 133,5 66 156
MVP 48
(9.8819) (5.9449) (3.6220) (5.2559) (2.5984) (6.1417)
257 157 92 133,5 66 156
MVP 60
(10.1181) (6.1811) (3.6220) (5.2559) (2.5984) (6.1417)
DCAT048-002 ID02 47
MVP
OPERATING CURVES
Curves have been obtained at the speed of 1500 min-1 and oil
temperature 50 °C (122 °F). PEC - LS2 (with flow control)
Not included
in supply
Normally Normally
closed open
VALVE FEATURES
Valve
Arrangement Volt
code
1 Normally closed 12 VDC
2 Normally closed 24 VDC
6 Normally open 12 VDC
7
O 05/10.2014
$
Volt 12 V (+/- 10%) 24 V (+/- 10%)
Limit current 1,7 A 0,85 A
#
Dither frequency 150 Hz 150 Hz
-40 °C ÷ 100 °C
Operating temperature (-40 °F ÷ 212 °F)
48 ID02 DCAT048-002
MVP
A B C D E F
Pump
type mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in)
232 132 86 127 61 144
MVP 30
(9.1339) (5.1969) (3.3858) (5.0000) (2.4016) (5.6693)
251 151 92 133,5 66 156
MVP 48
(9.8819) (5.9449) (3.6220) (5.2559) (2.5984) (6.1417)
257 157 92 133,5 66 156
MVP 60
(10.1181) (6.1181) (3.6220) (5.2559) (2.5984) (6.1417)
DCAT048-002 ID02 49
MVP
Replaces: 04/01.2012
Differential
Flow Standard
Pressure pressure
compensator setting
compensator setting range
type
bar (psi) bar (psi)
LS0 () RPO O
12 ÷ 40 14
LS2 () RPO (174 ÷ 580) (203)
LS3 (z) RPO
(): Suggested when the directional control valve does not have the
bleed function
(): Y is plugged. Suggested when the directional control valve has
the bleed function
In standard setting conditions 14 bar (203 psi) the stand-by LS3 - Remote pressure compensator
pressure is 15±2 bar (218±29 psi).
NOTES O
Available without pressure compensator RP.
For more information, please consult our technical sales
department.
O
OPERATING CURVES
Not included
Curves have been obtained at the speed of 1500 min-1 and oil
in supply
temperature 50 °C (122 °F).
Z Option
O (See page 40 for more information)
ΔQ max
O 05/10.2014
Pump type l/min (US gpm)
t1
Pump Response time [ms]
type (off stroke)
MVP 30 120
MVP 48 120
MVP 60 120
50 ID02 DCAT048-002
MVP
O
A B C D E
Pump
type mm mm mm mm mm
(in) (in) (in) (in) (in)
204 131,5 89 59,5 136
MVP 30
(8.0315) (5.1772) (3.5039) (2.3425) (5.3543)
223 151 95,5 64,5 143
MVP 48
(8.7795) (5.9449) (3.7598) (2.5394) (5.6299)
229 156 95,5 64,5 143
MVP 60
(9.0157) (6.1417) (3.7598) (2.5394) (5.6299)
DCAT048-002 ID02 51
MVP
TORQUE LIMITER RN
Replaces: 04/01.2012
than the value shown in the following table. Not included
in supply
For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard set-
ting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested
Z Option
value of torque [eg. 70 Nm (620 lbf in)] or the requested power O (See page 40 for more information)
and speed [eg. 10 kW (13.4 HP) at 1500 min-1].
OPERATING CURVES
Theoretical
O 05/10.2014
power
Z Option
O (See page 40 for more information)
52 ID02 DCAT048-002
MVP
TORQUE LIMITER RN
Replaces: 03/06.2011
O 05/10.2014
O
A B C D E F G
Pump
type mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in)
204 77 45 111 136 89,5 105,5
MVP 30
(8.0315) (3.0315) (1.7717) (4.3701) (5.3543) (3.5236) (4.1535)
223 69 37 103 143 93,5 109,5
MVP 48
(8.7795) (2.7165) (1.4567) (4.0551) (5.6299) (3.6811) (4.3110)
229 80 48 114 143 93,5 109,5
MVP 60
(9.0157) (3.1496) (1.8898) (4.4882) (5.6299) (3.6811) (4.3110)
DCAT048-002 ID02 53
MVP
Replaces: 04/01.2012
Not included
O
in supply
For lower torque setting values, the regulator limits the maxi-
mum working pressure to a value lower than the standard set-
ting for the pressure regulator 280 bar (4060 psi).
When ordering the torque limiter please specify the requested Z Option
value of torque [eg. 70 Nm (620 lbf in)] or the requested power (See page 40 for more information)
and speed [eg. 10 kW (13.4 HP) at 1500 min-1].
Valve
Arrangement Volt
code
1 Normally closed 12 VDC
Theoretical
2 Normally closed 24 VDC
power 6 Normally open 12 VDC
7 Normally open 24 VDC
O 05/10.2014
54 ID02 DCAT048-002
MVP
O
Replaces: 03/06.2011
O
O 05/10.2014
Pump
A B C D E F G H I L M
type mm mm mm mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in)
232 131,5 77 45 111 89 181,5 92 39 89,5 105,5
MVP 30
(9.1339) (5.1772) (3.0315) (1.7717) (4.3701) (3.5039) (7.1457) (3.6220) (1.5354) (3.5236) (4.1535)
252 151 69 37 103 95,5 188 97 44 93,5 109,5
MVP 48
(9.9213) (5.9449) (2.7165) (1.4567) (4.0551) (3.7598) (7.4016) (3.8189) (1.7323) (3.6811) (4.3110)
257 156 80 48 114 95,5 188 97 44 93,5 109,5
MVP 60
(10.1181) (6.1417) (3.1496) (1.8898) (4.4882) (3.7598) (7.4016) (3.8189) (1.7323) (3.6811) (4.3110)
DCAT048-002 ID02 55
MVP
UNLOADING VALVE U ..
Replaces: 03/06.2011
Z Option Z Option
(See page 40 for more information) (See page 40 for more information)
With the valve NC type (normally closed), energizing the sole- With the valve NA type (normally open), energizing the sole-
noid valve the displacement is reset and the pump is unloaded. noid valve the pump works at the maximum displacement.
NOTES O
Available without pressure compensator RP.
For more information, please consult our technical sales
department.
VALVE FEATURES
Valve
Arrangement Volt
code
U1 Normally closed 12 VDC
U2 Normally closed 24 VDC
O 05/10.2014
56 ID02 DCAT048-002
MVP
UNLOADING VALVE U ..
Replaces: 03/06.2011
O
O 05/10.2014
O
A B C D E
Pump
type mm mm mm mm mm
(in) (in) (in) (in) (in)
204 104 89 130 99
MVP 30
(8.0315) (4.0945) (3.5039) (5.1181) (3.8976)
223 110,5 94 137 105,5
MVP 48
(8.7795) (4.3504) (3.7008) (5.3937) (4.1535)
229 110,5 94 137 105,5
MVP 60
(9.0157) (4.3504) (3.7008) (5.3937) (4.1535)
Y: Connector. Standard type DIN 43 650 / ISO 4400. For other connectors please consult our technical sales department.
DCAT048-002 ID02 57
MVP
NOTES
03/06.2011
58 ID02 DCAT048-002
MVP
MULTIPLE PUMPS
THROUGH DRIVE
MVP through drive axial piston pumps offer the flexibility to obtain different groups able to supply several hydraulic systems. The
operating characteristics of each assembled pumps are the same as the corresponding single pumps according to the following
Replaces: 03/06.2011
conditions:
1) Do not exceed the maximum transmissible torque.
2) The maximum rotational speed is that of the lowest rated speed of the single unit incorporated.
Notes: The torque absorbed from the shaft of the first pump results from the sum of the torques due to all the single stages.
The achieved value must not exceed the maximum torque limit given for the shaft of the first pump.
A
Pump
Flanged for Code
type
SAE A AS1
MVP 30 O
SAE B AS5
MVP 48 SAE B AS5
MVP 60 SAE B AS5
DCAT048-002 ID02 59
MVP
O 05/10.2014
60 ID02 DCAT048-002
MVP
ANSI B92.1a-1976
Class 6 - 9 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side
DCAT048-002 ID02 61
MVP
O 05/10.2014
62 ID02 DCAT048-002
MVP
ANSI B92.1a-1976
Class 6 - 13 teeth
16/32 Pitch - 30 deg
Flat root - Side fit
Second pump side
DCAT048-002 ID02 63
MVP
O
Replaces: 03/06.2011
O 05/10.2014
64 ID02 DCAT048-002
MVP
MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in)
O
O 05/10.2014
DCAT048-002 ID02 65
MVP
Replaces: 03/06.2011
O 05/10.2014
66 ID02 DCAT048-002
MVP
MAX 200 Nm (1770 lbf in) MAX 250 Nm (2213 lbf in))
O O
DCAT048-002 ID02 67
MVP
Kit cover is available to obtain single pumps starting from the front sections of multiple pumps.
Before closing the intermediate flange check that the coupling has been removed.
Replaces: 03/06.2011
O
O 05/10.2014
68 ID02 DCAT048-002
MVP
NOTES
05/10.2014
DCAT048-002 ID02 69
MVP
1 2 3 4 5 6 7 8 ...
MVP30·28 S - 04 S5 - L MD/MB - N - ...
Replaces: 03/06.2011
1 Pump type (max. displacement) Code Code Inlet/outlet ports 6
3 3
28 cm /rev (1.74 in /rev) MVP 30·28 Nominal size
Inlet IN Outlet OUT Pump type
34,8 cm3/rev (2.12 in3/rev) MVP 30·34
SAE 3000 SAE 3000
45 cm3/rev (2.75 in3/rev) MVP 48·45
SAE FLANGED PORTS METRIC THREAD (SSM)
53,7 cm3/rev (3.28 in3/rev) MVP 48·53
MD/MB 1” 1/4 3/4” MVP 30
60 cm3/rev (3.66 in3/rev) MVP 60·60
ME/MC 1” 1/2 1” MVP 48
72 cm3/rev (4.39 in3/rev) MVP 60·72
MF/MC 2” 1” MVP 60
84,7 cm3/rev (5.17 in3/rev) MVP 60·84
SAE FLANGED PORTS UNC THREAD (SSS)
SD/SB 1” 1/4 3/4” MVP 30
2 Rotation Code SE/SC 1” 1/2 1” MVP 48
Anti-clockwise S SF/SC 2” 1” MVP 60
Clockwise D SAE STRAIGHT THREAD PORTS (ODT)
— — MVP 30
70 ID02 DCAT048-002
MVP
RP0 - Z - G
Pressure compensator
RP1 - Z - G
Flow compensator
LS0 - Z - G
DCAT048-002 ID02 71
MVP
8 9 10 11 12 13 14 15 16
Electro-proportional pressure
Replaces: 03/06.2011
compensator PEC - 1 - A - ... / ... - S - G
Electro-proportional pressure
compensator with flow control PEC - 1 - A - LS2 - ... / ... - S - G
Electro-proportional pressure
compensator plus angular sensor O PECA - 1 - A - ... ... S G
Electro-proportional pressure
compensator plus angular sensor O PECA - 1 - A - LS2 - ... ... - S - G
with flow control
Unloading valve
U.. - Z - G
Position 0° A
Position 90° B
(a) Only for PEC and PECA
(b) Only for PEC and PECA with flow control
ORDER EXAMPLE (c) Only for U.. unloading valve
MVP60 pump with electro-proportional pressure compensator
with flow control:
MVP60.60S-05S5-LMF/MC-N-PEC-1-A-LS2-100/300-S-G
72 ID02 DCAT048-002
MVP
TORQUE LIMITERS
O
8 9 10 11 12 13 14 15 16
Torque limiter - standard
Replaces: 03/06.2011
ORDER EXAMPLE
MVP60 pump with dual setting torque limiter with flow control:
MVP60.60S-05S5-LMF/MC-N-RN2-1-S-LS0-Z-G-150/200/2100
DCAT048-002 ID02 73
MVP
Common inlet O
1 2 3 4 5 6 7 8 ... 9 10 7 11 12 13 14
MVP30·28 S - 04 S5 - L MD/MB - N - ... - G - P7 - A (# / # / #) /
Replaces: 03/06.2011
Front section
KP20·6,3 S - - L **/GD - N5 - N - P
Rear section
74 ID02 DCAT048-002
MVP
Code Torque limiter setting (#) 12 Omit code only if ordering assembled multiple pumps
(#) Only for torque limiter. Refer to page 73 for more information.
... Please specify the requested torque value in Nm
Write these codes at the end only if ordering assembled
Replaces: 03/06.2011
multiple pumps
Code Second torque limiter setting (#) 13 (a) KAPPA 20 gear pumps:
... Please specify the requested torque value in Nm displacements on page 22, 26 and 30. For more information,
please see the respective technical catalogue
Code Torque limiter setting speed (#) 14 (b) POLARIS PH gear pumps
displacements on page 23, 27 and 31. For more information,
... Please specify the requested speed value please see the respective technical catalogue
(c) Drive shafts availability at pages 32 ÷ 35 and
mounting flanges availability at pages 36 ÷ 37
ORDER EXAMPLE
Common inlet double pump MVP 60 with RN1 torque limiter-internal pilot + PHP20 gear pump.
INDIVIDUAL SECTIONS
DCAT048-002 ID02 75
MVP
Through drive O
1 2 3 4 5 6 7 8 ... 9 10 11 12 13 14
MVP 60·60 S - 05 S5 - L MF/MC - N - ... - G - AS5 - 04 - (# / # / #) /
Front section (through drive)
Replaces: 03/06.2011
MVP 30·28 S - 04 S5 - L MD/MB - N - ... - G - - - ... / ... / ...
Rear section (single pump)
76 ID02 DCAT048-002
MVP
... Please specify the requested torque value in Nm (b) Drive shafts availability at pages 32 ÷ 35 and
mounting flanges availability at pages 36 ÷ 37
Replaces: 03/06.2011
ORDER EXAMPLE
Through drive double pump MVP 60 with RN2 (dual setting torque limiter with remote flow control) + MVP 30 with
LS0 flow compensator.
INDIVIDUAL SECTIONS
Through drive double pump MVP 48 with RN0 (standard torque limiter) + KP 30 gear pump.
O 05/10.2014
INDIVIDUAL SECTIONS
DCAT048-002 ID02 77
MVP
NOTES
05/10.2014
78 ID02 DCAT048-002
Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without
notice.
MVP 05 T A Edition: 05/10.2014 Replaces: MVP 04 T A
VARIABLE
DISPLACEMENT
Headquarters:
AXIAL PISTON
CASAPPA S.p.A.
Via Balestrieri, 1 PUMPS
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
IP Videoconferencing
E-mail: info@casappa.com
www.casappa.com