Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Function
1. Based on the usage scenario, two intra-frequency neighboring cells can be configured as bidirectional
or unidirectional neighboring cells. Assume that cell1 is configured as an intra-frequency neighboring cell
of cell2.
- If cell2 is also configured as an intra-frequency neighboring cell of cell1, cell1 and cell2 are bidirectional
neighboring cells.
- If cell2 is not configured as an intra-frequency neighboring cell of cell1, cell1 is a unidirectional
neighboring cell of cell2.
2. A maximum of 63 intra-frequency neighboring cells can be configured for a cell if
PERFENH_INTRAFREQ_NCELL_MAX_NUM_SWITCH of the PERFENHANCESWITCH4parameter in
the SET UCORRMPARA command is set to 0. As specified in 3GPP protocols, a maximum of 32
intra-frequency cells can be measured.
A maximum of 31 intra-frequency neighboring cells can be configured for a cell if
PERFENH_INTRAFREQ_NCELL_MAX_NUM_SWITCH of the PERFENHANCESWITCH4parameter in
the SET UCORRMPARA command is set to 1.
3. Before adding an intra-frequency neighboring cell, check whether this cell belongs to the local RNC or
another RNC. If the cell belongs to another RNC, run the ADD UEXT3GCELL command to add the
information of this cell first.
4. For a single host cell or primary host cell, the RNC ID is the ID of the serving RNC; for a secondary
host cell, the RNC ID is the ID of the RNC that controls the corresponding primary host cell. (Dual-homed
cell refers to the cell that has a peer cell in a RNC pool in the node redundancy function. Single-homed
cell refers to the cell that does not have a peer cell in a RNC pool in the node redundancy function. Both
primary cell and secondary cell are dual-homed cell. For details on the cell configuration, see the
parameter description of ADD UCELLSETUP.)
5. For a dual-homed cell, only the primary cell can be configured with neighboring cells. The secondary
cell cannot be configured with neighboring cells.
6.A cell can be configured as a neighboring cell of a maximum of 256 cells. This restriction is not
applicable to AP cells.
7.The RNC can be configured with a maximum of 163200 intra-frequency neighbor relationships.
Parameters
IdleQoffset2sn Offset 2 for Cell Meaning: Offset of the measured CPICH Ec/No used for cell res
Reselection in Idle In a cell reselection procedure, the RNC subtracts this offset from
Mode and then ranks all neighboring cells.
GUI Value Range: -50~50
Unit: dB
Actual Value Range: -50~50
MML Default Value: 0
Recommended Value: 0
Parameter Relationship: None
Service Interrupted After Modification: No (Impact on the UE in
Impact on Network Performance: If this parameter is set to a gre
neighboring cell as the target cell reduces. If this parameter is se
neighboring cell as the target cell increases.
SIB12Ind SIB12 Indicator Meaning: Whether to send the SIB12 carrying the neighboring c
TS 25.331. If this parameter is set to FALSE, the neighboring in
is set to TRUE, the neighboring information is included in SIB1
cell is preferentially selected as the target cell for access or cell r
CELL_DCH).
GUI Value Range: FALSE(Do not send), TRUE(Send)
Unit: None
Actual Value Range: FALSE, TRUE
MML Default Value: FALSE(Do not send)
Recommended Value: FALSE(Do not send)
Parameter Relationship: None
Service Interrupted After Modification: No (Impact on the UE in
Impact on Network Performance: None
ConnQoffset1sn Offset 1 for Cell Meaning: Cell offset used for CPICH RSCP measurement value
Reselection in connected mode.
Connected Mode During cell selection or reselection, QOffset1sn is the cell offse
the cell offset corresponding to CPICH Ec/No. For details about
QOffset1sn and QOffset2sn are used when the UE is in idle mo
used when the UE is in connected mode. ConnQoffset1sn and C
is available. The measured value of the neighboring cell minus t
ranking. This parameter needs to be set based on the actual situa
GUI Value Range: -50~50
Unit: dB
Actual Value Range: -50~50
Parameter ID Parameter Name Parameter Desc
TempOffset1 HCS Cell Reselect Meaning: Cell offset used for CPICH RSCP measurement value
TempOffset1 If this parameter is set to INFINITY, a neighboring cell is not se
GUI Value Range: D3, D6, D9, D12, D15, D18, D21, INFINITY
Unit: dB
Actual Value Range: 3, 6, 9, 12, 15, 18, 21, INFINITY
MML Default Value: D3
Recommended Value: D3
Parameter Relationship: None
Service Interrupted After Modification: No (Impact on the UE in
Impact on Network Performance: If this parameter is set to a larg
cell as the target cell decreases. If this parameter is set to a small
as the target cell increases.
TempOffset2 HCS Cell Reselect Meaning: Cell offset used for CPICH Ec/No measurement value
TempOffset2 If this parameter is set to INFINITY, a neighboring cell is not se
GUI Value Range: D2, D3, D4, D6, D8, D10, D12, INFINITY
Unit: dB
Actual Value Range: 2, 3, 4, 6, 8, 10, 12, INFINITY
MML Default Value: D2
Recommended Value: D2
Parameter Relationship: None
Service Interrupted After Modification: No (Impact on the UE in
Impact on Network Performance: If this parameter is set to a larg
cell as the target cell decreases. If this parameter is set to a small
as the target cell increases.
NPrioFlag Neighboring Cell Meaning: Whether to configure the priority flag for a neighborin
Priority Flag The value FALSE indicates that the neighboring cell priority is n
combination, the cell with an invalid priority is the last one to be
The value TRUE indicates that the neighboring cell priority is co
When the algorithm of neighboring cell combination (controlled
enabled and the total number of neighboring cells to all cells in t
parameter as one of conditions for selecting the neighboring cell
preferentially selected. If a neighboring cell is not configured wi
this cell.
GUI Value Range: FALSE, TRUE
Unit: None
Actual Value Range: FALSE, TRUE
Parameter ID Parameter Name Parameter Desc