SPECIFICATION SHEET

COMMERCIAL/EDUCATION
LEREN

Linear pendant with 63/37 up/down


light distribution
• Complete with adjustable wire
suspensions (Max 1500mm)

4000K WHITE CRI


>80
NEUTRAL 50,000 FINISH
HOURS
WHITE RAL9016

LUMINAIRE EFFICACY
CAT NO. DRIVER WATTAGE
LUMENS Llm/W
LER12W52S40 Standard 5200 58W 90
LER12W52E40 Emergency 5200 58W 90
LER12W52D40 Digital Dimmable 5200 58W 90
LER12W52ED40 Emergency Dimmable 5200 58W 90

1104mm 1184mm

65mm

234mm
AMBIENT TEMP. RATED LIFE (°C)
LUMINAIRE LUMENS (Llm)

LUMINAIRE WATTAGE (W)


W FIXING CENTRES (mm)

EMERGENCY PACK CODE


L FIXING CENTRES (mm)

CEILING CUTOUT (mm)


HEIGHT / DEPTH (mm)

WARRANTY (YEARS)
LENGTH / DIA (mm)

EFFICACY (Llm/W)

TEMP RANGE (°C)

B AT RATED LIFE

VOLTAGE RANGE
RATED LIFE (HR)

L AT RATED LIFE
GLOW WIRE (°C)

RAL COLOUR
WIDTH (mm)

FREQUENCY
WEIGHT (kg)

IK RATED
IP RATED
CCT (K)

UGR
CRI

-20 to 220-
LER12W52S40 1184 234 65 4.6 1104 N/A N/A 5200 58 90 4000 >80 ≤21 IP20 IK04 650 9016 +30
50,000 25 70 50 240V
50hz N/A 5

0 to 220-
LER12W52E40 1184 234 65 5.5 1104 N/A N/A 5200 58 90 4000 >80 ≤21 IP20 IK04 650 9016 +30
50,000 25 70 50 240V
50hz N/A 5

-20 to 220-
LER12W52D40 1184 234 65 4.6 1104 N/A N/A 5200 58 90 4000 >80 ≤21 IP20 IK04 650 9016 +30
50,000 25 70 50 240V
50hz N/A 5

0 to 220-
LER12W52ED40 1184 234 65 5.5 1104 N/A N/A 5200 58 90 4000 >80 ≤21 IP20 IK04 650 9016 +30
50,000 25 70 50 240V
50hz N/A 5

www.luceco.com
SPECIFICATION SHEET

COMMERCIAL/EDUCATION
LER12W52D40
LUMINAIRE PERFORMANCE
Light Output Ratio: 100%
Luminaire Efficacy: 88.48 lm/W
Light Distribution: B43 ↓63.3% ↑36.7%
CIE Flux Codes: 45 75 92 63 100
UGR 4H 8H (20%, 21.4 / 22.4
50%, 70%)C0 / C90:

LUMINOUS INTENSITY
150° 180° 150°

120° 120°

90° 90°

40

80

120
60° 60°
160

200

30° 0° 30°
C0 / C180 cd / 1000lm C90 / C270

STANDARDS
EN 60598-1 Luminaires - General requirements

EN 60598-2-1 Luminaires - Fixed general purpose

EN 60598-2-22 Luminaires - Emergency

EN 61347-1 Lamp controlgear - Part 1: General and safety requirements

Lamp controlgear - Part 2-13 : Particular requirements for d.c. or a.c. supplied
EN 61347-2-13
electronic controlgear for LED modules
Limits and methods of measurement of radio disturbance characteristics of electrical
EN 55015
lighting and similar equipment

EN 61547 Equipment for general lighting purposes - EMC immunity requirements

EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2: Limits - for harmonic current emissions

EN 62471 Photobiological safety of lamps and lamp systems

2002/96/EC Waste Electrical & Electronic Equipment (WEEE)

2011/65/EU Restriction of the use of certain Hazardous Substances in EEE (RoHS)

(EC) No 1907/2006 The Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)

www.luceco.com