Ejercicio 1

Datos
Tet: 303ºc Q = KA . T1-T2/ L
Tmt: 20ºc

Ll:100mm
Lfv: 0,05mm Kmp: 0,148 w/mºk
Lry:5cm Kfv:0,035 w/mºk
Ltp: 0,5pug Kl: 0,80 w/mºk
Q:? Ky: w/mºk =0,488
T:?

CONVECCIÓN A TRAVÉS DE PAREDES PLANAS

Qk= Tet-Tt / (L/K1)+(L/K2)+(L/K3)

Ll: 100mm (1mm/1000mm)=0.1m


Lry: 5cm (1m/100cm)=0.05m

Tt= ºk= 273+ºc


ºk=273+20ºc
ºk=293

Ltp: 0.5 pug x (1m/39.37pug)= 0.013m

Qk = 303ºk – 293ºk / (0.1m/0.80 (w/m.ºk) ) + (0.05m / 0.035 (w/m.ºk) ) + (0.05m /0.488


(w/m.ºk) ) + ( 0.013m / 0.15 (w/m.ºk) )

Qk= 10 ºk / 1,745 w/m2

Qk= 5,73 w/m2

TEMPERATURA DE INTERFACE
Qk= (ka/L)b x (T2-T3)

5,73 (W/M2) = (0.035 (W/MK) /0.05 ) x (303-T3)

5,73 (W/M2) / 0.7 (W/MºK) = (303 – T3)

8,2ºK=303 – T3
T3= 303 – 8,2

T3=294,8ºK

Qk= (Ka/L)C x (T3-T4)

5,73 (W/M2) = (0.488 (W/MK) / 0.05) x (294.8 – T4)


5,73 (W/M2) / 9.8 (W/MºK) = (294.8 – T4)
0.59ºK = (294.8 – T4)
T4= 294.8 – 0,58ºK
T4= 294,21ºK
Ejercicio 2
DATOS
Kfv: 0.035 w/mºk
Ky: 0.488 w/mºk
Km: 0.13 w/mºk
Lm: 1pug x (1m/39,37pug)=0.025m
Ly: 5cm x (1m/100cm)=0.05m

Qk= Kfv . A + Ky . A

Qk= 0.035 w/mºk x 350 M2 + 0.488 w/mºk x 350 m2

Qk= 183,05 w/mºk

Qk= (Kfv . A / Lfv) + (Ky . A / Ly) + (Km . A / Lm)

183,05 w/mºk = 12,25 (w/mºk) / Lfv + 170.8 (w/mºk) / 0,05ºk + 45,5 (w/mºk) / 0,02m
183,05 w/mºk = 12,25 (w/mºk) / Lfv + 3,42 w/mºk + 2,27 w/mºk
183,05 w/mºk = 12,25 (w/mºk) / Lfv + 5,7 w/ºk
12,25 w/mºk / Lfv = 183.05 w/mºk – 5,7 w/ºk
12,25 w/mºk = (188.75 w/ºk) Lfv
Lfv= 12,25 w/mºk / 188.75 w/ºk

Lfv= 0.06m