Está en la página 1de 2

Product Specification 36743

Dual Coil Solenoids

Cable Solenoid
Patented, remote cable link solenoid
can be used for throttle advance or
shutdown requirements. Ideal for
applications with space restrictions,
extremely hot environments or
excessive vibration.

Features:
• Remote mount for installation away from • Corrosion resistant plated steel housing
constrained or hostile environments and mounting
• Assembled with Model 2003ES high-force solenoid • Coils are potted to seal entire solenoid for reliable
• 8-14 pound return spring standard for start/stop service under extreme vibration, temperature, dirt,
applications. and moisture conditions
• Heavy-duty cable withstands temperature ranges of • Options include connectors, flexible conduit over
-63˚F to +250˚F (-53˚C to +121˚C) leads, and Coil Commander™ solenoid protection
• Spherical rod end with 0.237" (6 mm) diameter hole modules
• Patented

Solenoid Model 2003ES Features:


• 12 or 24 Vdc
• Base mount
• Ungrounded 3-wire leads
• Return spring 8 lbs (3.6 kg) at rated voltage, 68˚F
(20˚C) and 1" (25.4 mm) stroke

Order Information:

ORDER NO. Voltage

SA-4744-12 12 Vdc

SA-4744-24 24 Vdc

E.E.C. Directive Compliance: All parts supplied by Woodward are classified as components, and therefore are not “CE” marked. Please contact
factory direct for details on specific product compliance with 89/336/EEC and 89/392/EEC directives.

26 www.woodward.com
Product Specification 36743

DIMENSIONS

C
L
5.10" REF
.964" PLUNGER STROKE [129.5 mm] NOMINAL SUPPORT BRACKET LOCATION FOR
[24.5 mm] CABLE BULKHEAD. BRACKET LOCATION

Dual Coil Solenoids


3.13" REF TO BE ADJUSTED BY CUSTOMER.
ø.237" (BRACKET NOT SUPPLIED)
[79.5 mm]
[6.02 mm]

ø.41" REF
[10.4 mm]
ø.47" REF
.75" [11.9 mm] 50.40"
[19.0 mm] [1280.1 mm]

.91" REF 41.08" REF


[22.9 mm] 4.21" REF [1043.4 mm]
[106.9 mm]
12.0"
[305 mm]

9/16-18 NUT
2.756" 3.39"
[70.00 mm] [86.1 mm]

PAT.#378,513
1.375" HEX REF
[34.93 mm]

"E-BASE" ø2.03" MAX


1.500" .135"
[38.10 mm] [51.6 mm]
[3.42 mm]
ø.345" HOLE THRU 1.179"
2.25" [29.95 mm]
[8.76 mm] (4-PLACES)
[57.2 mm]

NOTE: Minimum bend radius for optimum cable life is 5" (127 mm)

Specifications: Force vs. Stroke


90
At rated voltage, 68˚F (20˚C) (400)
and .964" (24.5 mm) stroke 80
(356)
70
Voltage 12 Vdc 24 Vdc (311)
Pull Current 61.8 A 39.0 A 60
Hold Current 0.85 A 0.46 A (267)
Force – lbs (N)

50
Pull Force 29 lbs (129 N) (222)

Hold Force 41 lbs (182 N) 40


(178)
Cable Length 41.08" (1043.4 mm) 30
(133)
Total Length 50.4" (1280.1 mm) 20
(88)

10
(44)
0
0 0.2 0.4 0.6 0.8 1
(5.08) (10.16) (15.24) (20.32) (25.4)
0.1 0.3 0.5 0.7 0.9
(2.54) (7.62) (12.70) (17.78) (22.86)

Stroke – in (mm)

Specifications and dimensions are for reference only.