Unidades: Presion (MPa), Temperatura (ºC)

Entalpía de liquido saturado (kJ/kg)

H_L_Sat =E= 0.001 * (5415.943543 * ((T + 273.15) - TREF) - 3.771131883 * (POWER(((T + 273.15)), 2) - POWER(TREF, 2)) +
0.00382052 *(POWER(((T + 273.15)), 3) - POWER(TREF, 3))) ;

Entalpía de vapor saturado (kJ/kg)

H_V_Sat =E= (2041.21 - 40.40021 * P /1000 - 0.48095 * POWER(P/1000, 2) +(1.610693 + 0.05472051 * P/1000 +
0.0007517537* POWER(P/1000, 2))*(T + 273.15) + (0.0003383117 -0.00001975736 * P/1000 - 0.000000287409*
POWER(P/1000, 2))*POWER((T + 273.15), 2) - (1707.82 - 16.99419 * (T + 273.15) + 0.062746295 * POWER((T + 273.15) , 2) -
0.00010284259* POWER((T + 273.15), 3) + 0.000000064561298 * POWER((T + 273.15) ,4)) * EXP(((T + 273.15) - (T +
273.15))/45)) ;

Entalpía de vapor recalentado (kJ/kg)

H_V_Rec =E= (2041.21 - 40.40021 * P /1000 - 0.48095 * POWER(P/1000, 2) +(1.610693 + 0.05472051 * P/1000 +
0.0007517537* POWER(P/1000, 2))*(T_Rec + 273.15) + (0.0003383117 - 0.00001975736 * P/1000 - 0.000000287409*
POWER(P/1000, 2))* POWER((T_Rec + 273.15), 2) - (1707.82 - 16.99419 * (T_Sat + 273.15) + 0.062746295 * POWER((T_Sat
+ 273.15) , 2) - 0.00010284259* POWER((T_Sat + 273.15), 3) + 0.000000064561298 * POWER((T_Rec + 273.15) ,4)) *
EXP(((T_Sat + 273.15) - (T_Rec + 273.15))/45)) ;

Calor Latente de Vaporarización (kJ/kg)

Q_Lat * 0.239005736 =e= (2589.583+0.9156*((T+273.15))- 0.0048343*(POWER(((T+273.15)), 2)))/ 4.1868 ;

Relación entre la presión y temperatura en la condición de saturación

(LOG(P/1000)-9.48654) * (T + 273.15) =E= (LOG(P/1000)- 9.48654)*42.6776 + (-3892.70) ;