Está en la página 1de 21

Engineering Data Pack

HD Industrial Duty Pumps

Version 1.7 Excellence at work. Excellence in life.


Table of Contents
70A Pump Mounting Dimensions 3 HD Maximum Overhung Load Calculation 17
70A Pump Mounting Dimensions with Flanged Ports 3 HD Maximum Allowable Transmitted Torque on Pump Shafts
(Inch-Pounds) 18
Flanged Port Dimensions 3
HD Nozzle Loading Data 18
120A Pump Mounting Dimensions 4
HD Model Steam Jacket 18
120A Pump Mounting Dimensions with Flanged Ports 4
General Ph Chart 19
Flanged Port Dimensions 4
HD Maximum Case, Differential, Discharge, and Suction
330 Pump Mounting Dimensions 5 Pressures 19
330 Pump Mounting Dimensions with Flanged Ports 5 Flange Ratings (Cast Iron) 20
Flanged Port Dimensions 5 Flange Ratings (Stainless Steel) 21
600 Pump Mounting Dimensions 6
600 Pump Mounting Dimensions with Flanged Ports 6
Flanged Port Dimensions 6
HD Process Pump Numbering System 7
Temperature Limits of HD Process Pump Materials 7
HD Industrial Duty Pump Materials of Construction 8
HD Seal Specifications 9
HD NPSHr Data 11
Industrial Duty Seal Chamber Dimensions 11
Priming Ability of HD Series Pumps 12
Maximum Speed Vs. Viscosity 13
Horsepower Multiplying Factor Vs. Viscosity 13
Model 70A Impeller and Timing Gear Chart 14
Model 120A Impeller and Timing Gear Chart 14
Model 330 Impeller and Timing Gear Chart 14
Model 600 Impeller and Timing Gear Chart 14
Abrasives & Slurries 15
Spherical Particle Size Data 15
Particle Size Reference 16
Packing Style Arrangements 16

Version 1.7 Page 2 of 21


70A Pump Mounting Dimensions
3 7
2416
134
3" NPT PORT 127
8 1
SUCTION 1 22
1 2 SQUARE KEY
32 1 LONG
22

Ø17
8

1
134
1
64
1
82

5
8

(4) 13
32 TYP.
2" NPT PORT MTG. HOLES 1
32
DISCHARGE 1 1 5
12 42 88 7

13 8
816

70A Pump Mounting Dimensions with Flanged Ports


3 7
2416
134
"X" 127
8
3" NPT FLANGED 1
22
SUCTION PORT

1 1
32 2 SQUARE KEY
1 LONG
22
Ø17
8

"Y"
1
64
1
82

5
8

(4) 13
32 TYP.
2" NPT FLANGED MTG. HOLES 1
32
DISCHARGE PORT 1 1 5
12 42 88 7

13 8
816

Flanged Port Dimensions


Iron Pump Stainless Steel Pump
Size
CS ANSI 150# F.F. CS ANSI 150# R.F. CS ANSI 300# R.F. SS ANSI 150# F.F. SS ANSI 150# R.F. SS ANSI 300# R.F.
"X" 14 23/32" ± 1/2" 14 23/32" ± 1/2" 15 1/32" ± 1/2" 14 23/32" ± 1/2" 14 23/32" ± 1/2" 15 1/32" ± 1/2"
"Y" 15 5/32" ± 1/2" 15 5/32" ± 1/2" 15 21/32" ± 1/2" 15 5/32" ± 1/2" 15 5/32" ± 1/2" 15 21/32" ± 1/2"

Version 1.7 Page 3 of 21


120A Pump Mounting Dimensions
3 7
2416
134
4" NPT PORT 3
128 1
22
SUCTION 1
1 2 SQUARE KEY
32 1 LONG
22

Ø17
8

1
134
1
64
1
82

5
8

(4) 13
32 TYP.
3" NPT PORT MTG. HOLES 1
32
DISCHARGE 1 1 5
12 42 88 7

13 8
816

120A Pump Mounting Dimensions with Flanged Ports


7
2416
3 1 "X" 3 1
22
134 1432 128

4" NPT FLANGED


SUCTION PORT 1
32

1
2 SQUARE KEY
1 LONG
22 3
"Y"154
Ø17
8

1
64
1
82

5
8

(4) 13
32 TYP.
MTG. HOLES
1
32
1
12 1
42 5
88
3" NPT FLANGED 7
DISCHARGE PORT 8
13
816

Flanged Port Dimensions


Iron Pump Stainless Steel Pump
Size
CS ANSI 150# F.F. CS ANSI 150# R.F. CS ANSI 300# R.F. SS ANSI 150# F.F. SS ANSI 150# R.F. SS ANSI 300# R.F.
"X" 13 17/32" ± 1/2" 13 17/32" ± 1/2" 14 1/32" ± 1/2" 13 17/32" ± 1/2" 13 17/32" ± 1/2" 14 1/32" ± 1/2"
"Y" 15 3/8" ± 1/2" 15 3/8" ± 1/2" 15 3/4" ± 1/2" 15 3/8" ± 1/2" 15 3/8" ± 1/2" 15 3/4" ± 1/2"

Version 1.7 Page 4 of 21


330 Pump Mounting Dimensions
3
178 2915
32
9
1432
5" NPT PORT 3
316
SUCTION 4 1
2 SQUARE KEY
1 LONG
34

1
Ø24

167
8
8

3
104

7
8

(4) 17
32 TYP.
MTG. HOLES 3
4" NPT PORT 1
24 7 815
32
44
DISCHARGE 3 1
92
1116
1141

330 Pump Mounting Dimensions with Flanged Ports


3
178 2915
32
"X" 9
1432
3
316
5" NPT FLANGED
SUCTION PORT 4

1
2 SQUARE KEY
1 LONG
34 "Y"

1
Ø24

3
104

7
8

(4) 17
32 TYP.
MTG. HOLES 1
24 7 815
32
3
1116 3
4" NPT FLANGED 44
DISCHARGE PORT 1
92

1141

Flanged Port Dimensions


Iron Pump Stainless Steel Pump
Size
CS ANSI 150# F.F. CS ANSI 150# R.F. CS ANSI 300# R.F. SS ANSI 150# F.F. SS ANSI 150# R.F. SS ANSI 300# R.F.
"X" 18 3/32" ± 1/2" 18 3/32" ± 1/2" 18 21/32" ± 1/2" 18 3/32" ± 1/2" 18 3/32" ± 1/2" 18 21/32" ± 1/2"
"Y" 19" ± 1/2" 19" ± 1/2" 19 9/16" ± 1/2" 19" ± 1/2" 19" ± 1/2" 19 9/16" ± 1/2"

Version 1.7 Page 5 of 21


600 Pump Mounting Dimensions
9
3616
1 9
182 TYP.
11
532

1
2 SQUARE KEY
1 LONG
44
1
Ø22

1
32
11
2032

3
134

1
116

Ø1 TYP.
MTG. HOLES 57
8
3
316 7
1116 5
78 3
114
29
1532 1
132
(2) 6" NPT PORTS

600 Pump Mounting Dimensions with Flanged Ports


9
3616
1
182 "X" TYP.
11
532

1
2 SQUARE KEY
1 LONG
44
1
Ø22

1
32
11
2032

3
134

1
116

Ø1 TYP.
MTG. HOLES 57
8
3
316 7
1116 5
78 3
114
(2) 6" NPT
29
1532 FLANGED PORTS 1
132

Flanged Port Dimensions


Iron Pump Stainless Steel Pump
Size
CS ANSI 150# F.F. CS ANSI 150# R.F. CS ANSI 300# R.F. SS ANSI 150# F.F. SS ANSI 150# R.F. SS ANSI 300# R.F.
"X" 11 5/32" ± 1/2" 11 5/32" ± 1/2" 11 21/32" ± 1/2" 11 5/32" ± 1/2" 11 5/32" ± 1/2" 11 21/32" ± 1/2"

Version 1.7 Page 6 of 21


HD Process Pump Model Number System

Construction

Double Lobe
Relief Valve
Material of

Number
Options
Model
Pump

Serial
Port
Position # 1 2 3 4 5 6 7 8 9 10 11 12 13
Pos. 1 & 2 - Pump Pos. 8 - Relief Valve Pos. 11 & 12 - Serial Number
O5 = Industrial Duty (ID) 0 = No Relief Valve 01
02
Pos. 3 & 4 - Model Pos. 9 & 10 - Options etc. = (Serialized at the Factory)
16 = Model 70A 01 = Hot Clearance
Pos. 13 - Double Lobe
31 = Model 120A 02 = Special Shaft Material
75 = Model 330 05 = Special Packing D = Double Lobe (If Required)
91 = Model 600 06 = Special Packing Configuration
08 = Mechanical Seals
Pos. 5 & 6 - Material of Construction 09 = Special Bushings
04 = 316 Stainless Steel 10 = Special Clearances
09 = Ductile Iron 13 = Steam Jacket/Tracing
19 = Special Ports (ie. Flanged)
Pos. 7 - Port 21 = Tutriding
0 = Internal NPT (Std. on ID Models) 26 = Interference Fit Gears
3 = Flanged Port Option 27 = Special U-Cup/Lip Seals
28 = Miscellaneous

Temperature Limits of HD Process Pump Materials


550 °F

525 °F

High Temp Carbon Bushings


Viton Oil Seals - Faceplate &

PTFE Oil Seals - Faceplate &

Ductile Iron Pumps


Carbon Bushings -

- Stainless Steel Pumps


High Temp APG 250

500 °F
Gearcase Oil

PTFE-Glass Filled
Gearcase

Gearcase

Standard DU Bushings - Ductile Iron Pumps


Hot Clearance Impellers

Gaskets

450 °F
Gor-Tex Rope Gaskets

400 °F
W C Bushings
Standard Packing

Bronze Bushings - Ductile Iron Pumps

350 °F
Standard Oil Seals - Faceplate &

Standard Oil Seals - Faceplate &

Standard Carbon Bushings -


Standard Gasket Material

300 °F
Standard Gearcase Oil

Stainless Steel Pumps


Gearcase

Gearcase

150 °F
Standard Pump
Materials

100 °F

-40 °F

Note: Viton and PTFE oil seals can be used in place of standard oil seals upon request. PTFE and Gor-Tex gaskets can be used in place
of standard seals upon request. If using a Mechanical Seal please consult factory for temperature limitations.
Version 1.7 Page 7 of 21
HD Industrial Duty Pump Materials of Construction
Availability
Part Name Material Standard Comments
DI SS
Ductile Iron ASTM A536, grade 80-55-06 187-255 Brinell Hardness S
Impeller Housing Stainless Steel ASTM A743, grade CF-8M 155-185 Brinell Hardness S
Tutrided Ductile Iron ASTM A536, grade 80-55-06 Surface Hardened O
Ductile Iron ASTM A536, grade 80-55-06 187-255 Brinell Hardness S
Faceplate Stainless Steel ASTM A743, grade CF-8M 155-185 Brinell Hardness S
Tutrided Ductile Iron ASTM A536, grade 80-55-06 Surface Hardened O
Gearcase Cast Iron ASTM A48 S S
Gearcas Cover Cast Iron ASTM A48 S S
Ductile Iron ASTM A536, grade 80-55-06 S
Impellers Stainless Steel ASTM A743, grade CF-8M 155-185 Brinell Hardness S
Tutrided Ductile Iron ASTM A536, grade 80-55-06 Surface Hardened O
High Strength Steel ASTM A564, grade 630 Armco 17-4PH S S
Drive & Driven Shafts C.O. Coated High Strength Armco 17-4PH Chrome
ASTM A564, grade 630 O O
Steel Oxide Coated
Carbon Carbon Graphite Resin S
Housing Bushing
DU Bushing Steel Backed / PTFE Coated S
Gearcase Ball Bearing Steel S S
Faceplate Ball Bearing Steel S S
Steam Jacket Aluminum O O
DI = Ductile Iron Pumps SS = Stainless Steel Pumps S = Standard O = Optional

Version 1.7 Page 8 of 21


HD Seal Specifications
Packing

Packing Description Packing Style Material Description


Standard Packing (Graphite/PTFE) ML4002 or ML8002 Braided PTFE with graphite impregnation
ML2236FDA Braided pure PTFE (FDA approved)
Pure PTFE Packing
ML2235 Braided pure PTFE (Not FDA approved)
PTFE
Optional Lantern Ring (Style 2, 3 & 4 Packing)
303 Stainless Steel
PTFE
Throttle Bushing (Style 4 Packing)
303 Stainless Steel

Mechanical Seal

Material of Construction
Seal Description Seal Type
Secondary Seal Rotating Face Stationary Face Hardware
Single Abrasion Resistant Mechanical Seal 82 Viton Tungsten Carbide Silicon Carbide 316 S.S
Single Abrasion Resistant Mechanical Seal 82 Chemraz Tungsten Carbide Silicon Carbide 316 S.S.

Cartridge Seal

Material of Construction
Seal Description Seal Type
Secondary Seal Sleeves Lips Gasket Hardware
Triple Lip Cartridge Seal 42 Chemraz Zirconium PTFE Gylon 316 S.S.

Note: Tuthill can supply a variety of seals with different material combinations to suit specific application requirements. The above
list displays the most common/standard seal combinations used. Viton® - Registered trademark of E.I. DuPont De Nemours & Company
Gylon® - Registered trademark of Garlock, Inc.

Version 1.7 Page 9 of 21


Version 1.7
FACEPLATE HOUSING GEARCASE X
A
K STUDS B

V
L

J
CD

CD

MIN.
ØF
ØS
D

D
A

M
SHAFT
CENTERS

SECTION A - A H E R W SECTION B - B
A B

"H" "J" "L" "M" "K STUDS" "V" "X"


MODEL "A" "B" "D" "E" "F" "CD" "R" "S" "W" MIN.
S.S. D.I. S.S. D.I. S.S. D.I. S.S. D.I. QTY. SIZE S.S. D.I.
30A 2.5005 3 1.504 15 .9985 1.567 2 2 13 13 1 7 1 7 NO 8 3 - 16 15 1.000 1 7 1 7 2 3 1 31
2.4995 1.498 8 .9980 1.560 16 16 16 16 CENTER RIB 8 8 .9995 16 16 16 32
2A 4.0005 31 1.878 21 1.374 2.067 2 1 2 1 11 11 1 7 1 1 1 25 1 25 8 3 - 16 21 1.3750 11 11 2 5 2 9
3.9995 2 1.873 8 1.373 2.060 16 16 2 2 16 2 32 32 8 8 1.3745 2 2 8 16
3A 4.0005 31 1.878 21 1.374 2.067 2 1 2 1 1 21 1 21 7 1 1 1 25 1 25 8 3 - 16 21 1.3750 11 11 2 5 2 9
3.9995 2 1.873 8 1.373 2.060 16 16
1 16 2 32 32 8 8 1.3745 2 2 16 16
70A 5.0005 3 5 2.758 2 7 1.869 NONE 2 3 2 11 2 16 3 2 3 1 21 1 21 2 15 2 1 8 3 - 16 27 1.8745 1 1 1 21 2 5 3
4.9995 8 2.752 8 1.868 8 32 16 64 4 8 8 1.8740 2 16
120A 5.0005 35 2.758 2 7 1.869 NONE 2 3 2 11 2 3 2 3 1 21 1 21 2 15 2 1 8 3 - 16 27 1.8745 11 1 21 2 5 3
4.9995 8 2.752 8 1.868 8 32 16 16 64 4 8 8 1.8740 2 16
330 6.4005 41 3.255 3 5 2.244 NONE 3 1 3 7 2 21 2 1 2 2 2 15 2 61 8 1 - 13 3 5 2.2488 2 2 3 1 35
6.3995 4 3.250 16 2.243 8 32 2 16 64 2 16 2.2480 16 8
600 7.0005 6 3 3.510 31 2.494 NONE 4 1 3 7 2 3 2 5 3 2 1 31 3 7
2 16 8 5 - 11 31 2.4988 2 2 3 3 31
6.9995 4 3.505 4 2.493 16 8 4 8 16 4 32 8 4 2.4980 4 8

D = STUFFING BOX BORE J = LENGTH TO OBSTRUCTION R = STUFFING BOX DEPTH HOUSING


E = STUFFING BOX BORE DEPTH FACE PLATE L = STUD LENGTH FACEPLATE S = SHAFT DIAMETER HOUSING
F = FACEPLATE SHAFT DIAMETER M = LENGTH TO OBSTRUCTION V = STUD LENGTH
H = LENGTH TO OBSTRUCTION FACEPLATE SIDE K = STUD INFORMATION W = LENGTH TO NEAREST OBSTRUCTION

Page 10 of 21
HD NPSHr Data
40 1.2

500K
SSU
1 MM
SSU

250 K 1.0
SSU 100K
SSU
30

0.8
NPSHr (Feet of Water)

20 0.6

Bar
60K SSU 5K SSU

0.4
31 SSU

10

31 SSU
5000 SSU
0.2
60000 SSU
100000 SSU
250000 SSU
500000 SSU
1000000 SSU

0 0.0
0 100 200 300 400 500 600
Pump Speed (RPM)

Version 1.7 Page 11 of 21


Priming Ability of HD Series Pumps
Performance curves indicating priming ability of pumps based on test data obtained on new pumps. Priming ability of older pumps,
because of larger clearances, will not be as good.

DUCTILE IRON (STD. CLEARANCE) DUCTILE IRON (HOT CLEARANCE)


16 STAINLESS STEEL (STD. CLEARANCE)
8

14
4
2
12
6

10 3

METERS OF WATER
FEET OF WATER

METERS OF WATER
FEET OF WATER

0
60
8

0/
4

3
/3
0

0A
0
/6

12
2
30

6 1
/3
0A
12

4 2
70A 70A
1

0 100 200 300 400 500 600 0 100 200 300 400 500 600
RPM RPM

STAINLESS STEEL (HOT CLEARANCE)


1.6 .5

1.2
METERS OF WATER
FEET OF WATER

00
/6
30
/3

.80 .25
0A
12

.40
70A

0 100 200 300 400 500 600


RPM

Version 1.7 Page 12 of 21


Maximum Speed Vs. Viscosity
500

450

400

350

300

250

200

150

100

50

0
10000 100000 1000000 10000000
Viscosity (SSU)

Horsepower Multiplying Factor Vs. Viscosity


3.5

Procedure:
3.0 1.) Determine required horsepower from 60,000 SSU
performance curve for specific pump size, speed
and operating pressure.
2.) Determine factor for required viscosity.
3.) Multiply answer 1 and 2 for required BHP.
BHP Multiplying Facto

2.5

2.0

1.5

1.0
10000 100000 1000000 10000000
Viscosity (SSU)

Version 1.7 Page 13 of 21


Model 70A Impeller and Timing Gear Chart Model 330 Impeller and Timing Gear Chart

400
400
CONSULT
350 FACTORY CONSULT
350
FACTORY
300
300

250 INTERFERENCE FIT


TIMING GEARS 250
NEEDED
RPM

RPM
200
200

150
150
INTERFERENCE
100 FIT TIMING
100
GEARS NEEDED
50
50

0 50 100 150 200 250 300 350 400


PSI 0 50 100 150 200 250 300 350 400
SINGLE LOBE PSI
IMPELLERS NEEDED SINGLE LOBE
IMPELLERS NEEDED
Note: Single or double lobe impellers are satisfactory for full
range shown.

Model 120A Impeller and Timing Gear Chart Model 600 Impeller and Timing Gear Chart

400 400
CONSULT
350 FACTORY 350 CONSULT
FACTORY

300 300

250 INTERFERENCE FIT


TIMING GEARS 250
NEEDED
RPM

RPM

200
200

150
150
INTERFERENCE
100 FIT TIMING
100
GEARS NEEDED

50
50

0 50 100 150 200 250 300 350 400


0 50 100 150 200 250 300 350 400
PSI
SINGLE LOBE PSI
IMPELLERS NEEDED SINGLE LOBE
IMPELLERS NEEDED

Version 1.7 Page 14 of 21


Abrasives & Slurries
The Tuthill process pump is ideally suited for slurries, since it is capable of handling a wide range of apparent viscosities and solid
particle sizes. When sizing a process pump, you must determine the viscosity of the carrier fluid, particle size, and particle hardness.
The thicker the carrier fluid, the less recirculation of product through the fluid chamber clearances (slip), thus there is less erosive wear
from any abrasive particle. If the carrier fluid is water thin, the abrasive particles are allowed to re-circulate in the clearances, resulting
in a short wear life.
Particle size and hardness both affect the wear life of a process pump. Each process pump model has different clearance dimensions.
If the particle is harder than the pump material construction and larger than the clearance dimension, the pump will generally have
initial wear equal to that of the particle size and level off to a slower, constant wear rate. If the particle size is smaller than the pump
clearances, the wear is less of a problem. A particle is therefore defined as abrasive if it is equal to or harder then the pump construction
and larger then the factory set clearances in a new pump.
Knowing that the process pump has been successfully applied on abrasive slurries, we generally do not recommend pump speeds on
inorganic slurries to be any greater than 190 RPM. Try to maintain slowest possible speeds for any abrasive slurry. Wear life is relative;
the Tuthill process pump will always do better than gear or vane pump at identical operating speeds.

The following are MAXIMUM recommended pump speeds for existing applications
Waste solvents, oil, paints, etc 230 RPM
Municipal sludge/scum 190 RPM
Animal rendering 100 RPM
Asphalt with filler 100 RPM
Magnetic oxide slurries 150 RPM
Grain slurries (mash) 150 RPM
Clay coatings slurries 280 RPM
Clay slip & ceramic slurries 50 RPM
Coal oil surface 190 RPM

Spherical Particle Size Data


The chart below shows the theoretical maximum, and recommended maximum particle size that a pump will pass. This is strictly a
function of geometry. Pumps will last longer if abrasive particles are smaller than internal pump clearances and softer than the internal
pump parts. On slurries with maximum diameter particles, 100-RPM maximum speed is recommended to minimize crushing. Particles
must be able to be sheared by pump impellers or the pump will stall.

Pump Model Theoretical Maximum Diameter (inches) Recommended Maximum Diameter (inches)
70A 1.250 .750
120A 1.500 .875
330 2.250 1.000
600 3.000 1.250

Version 1.7 Page 15 of 21


Particle Size Reference

Mesh Micron Inches


400 37 .0015
200 74 .0029
100 149 .0059
50 297 .0117
20 841 .0331
10 2000 .0787
3 6730 .2650

Packing Style Arrangements


Style #1

PACKING
SHAFT

GLAND

Available Options:
• Packing: Pure PTFE, Graphite, other special materials available on request
• Shaft: Steel, Armco 17-4PH, 316 S.S. (all have ceramic coating option)
• Style #1 packing is the standard for all HD models

Version 1.7 Page 16 of 21


Style #2 (Lantern Ring)

PACKING
SHAFT

LANTERN
RING

GLAND

Recommended Usage:
• Grease lubrication improves sealing and packing life
• Vent to suction side of pump to reduce pressure on outboard packing
• Flush with clean fluid at 15-20 PSI above pump discharge pressure
• Some product dilution will occur so compatible fluid must be used
This design is the same as Style #1 except lantern ring and “in” and “out” flush connections are provided in the approximate location
shown. A minimum of two rings of packing will be installed inboard to throttle flow. Standard lantern ring material is glass filled PTFE.
Rings may be made in other materials as required. All available options from Style #1 apply.

HD Maximum Overhung Load Calculation

Maximum Horsepower with 12” diameter sheave Pump RPM


Ductile Iron Model Max. Overhung Load – “F” (lbs.)
100 200 300 400
70A & 120A 450 4.3 8.6 12.9 17.2
330 600 5.7 11.4 17.1 22.8
600 900 8.6 17.2 25.8 34.4
Use following formula for other speed and sheave diameters
HP = (“F” – lbs.) (Sheave dia. - inches) (RPM)
126,048
Note: Stainless Steel will be 67% of above.

Version 1.7 Page 17 of 21


HD Maximum Allowable Transmitted Torque on Pump Shafts (Inch-Pounds)

Pump Shaft Carbon Steel 1141 (Std. On D.I.) ARMCO 17-4-1025 316 S.S. (Std. On S.S.) Hast “C”
70A & 120A 12,534 19,497 6,267 10,213
330 21,658 33,691 10,829 17,647
600 29,710 46,215 14,855 24,208
*Transmitted torque is the torque associated with the brake horsepower of a given application, at design speed.
To calculate torque values in inch pounds determine BHP for the actual application from published performance curves, at design
speed (RPM).
Torque (in-lbs.) = (BHP)(63,000)
RPM
Note: Applications using 31 SSU performance curves at pressures at or above 200 PSI must be approved by the factory.

HD Nozzle Loading Data

Pump Model Port Size (In.) Max. Force = Lbs. Max. Moment = Lb.In.
120A 3 200 2750
120A & 330 4 250 3150
330 5 300 3600
600 6 500 4100

HD Model Steam Jacket

Construction

The jacket has a fabricated carbon steel plate type insert with an aluminum cast outer shell. Jacket is made in two-piece construction
for field installation and/or pump maintenance access. Each half has ½” NPT (internal) in and out ports.
Rating:
• Steam or heat transfer fluids
• 150-PSI maximum pressure
• 500°F maximum temperature

Version 1.7 Page 18 of 21


Application

Factory or field installed. Standard grade Thermon or other heat transfer cement is applied between pump and jacket for best efficiency.
Applications where pumped fluid must be maintained at temperature in order to remain in liquid form so the pump can pump the fluid
are ideal for a steam jacket.

General Ph Chart

14.0 Ph
13.0 Ph
12.0 Ph
Increasing Alkalinity 11.0 Ph
10.0 Ph Ductile Iron
9.0 Ph
8.0 Ph
Neutral Point 7.0 Ph
6.0 Ph
5.0 Ph
4.0 Ph
Increasing Acidity 3.0 Ph
Stainless Steel
2.0 Ph
1.0 Ph
0.0 Ph

HD Maximum Case, Differential, Discharge, and Suction Pressures

A B

SUCTION PUMP DISCHARGE

Version 1.7 Page 19 of 21


Pump Model Pump Material Max. Case Max. Differential Max. Discharge Max. Suction
of Construction Pressure Pressure Pressure Pressure
70A Ductile Iron 500 450 500 350
Stainless Steel 500 450 500 350
120A Ductile Iron 500 450 500 350
Stainless Steel 500 450 500 350
330 Ductile Iron 500 450 500 350
Stainless Steel 500 450 500 350
600 Ductile Iron 500 450 500 350
Stainless Steel 500 450 500 350
* Max. Case Pressure for Standard Duty models with wing nuts is 150 PSI for Stainless Steel and 200 PSI for Ductile Iron. 500 PSI rating
can be achieved by replacing wing nuts with standard hex head nuts torqued to industry standards.

Flange Ratings (Cast Iron)


Temperature (deg C)
-45 5 55 105 155 205 255 305
300
20

ANSI 250#

Pressure (bar g)
200
Pressure (psig)

10
ANSI 125#
100

0 0
-50 0 50 100 150 200 250 300 350 400 450 500 550 600
Temperature (deg F)

ThIs chart shows the ratings for flanges only - the maximum pump operating conditions must also be checked.
Consult the appropriate Tuthill catalog for maximum allowable operating pressures and temperatures, based on pump application
conditions and pump features.
These ratings are based on non-shock pressures.
ANSI data is from ASME/ANSI B16.1 - 1989 (class A). Consult this spec for more information.
WARNING
Rapid temperature change can result in flange failure and leakage, which can cause property damage or serious injury. Do not exceed
cast iron tensile strength when bolting flanges.

Version 1.7 Page 20 of 21


Flange Ratings (Stainless Steel)
Temperature (°C)

-45 5 55 105 155 205 255


300
20

200
ANSI 150#

Pressure (bar g)
Pressure (psig)

10

100

0 0
-50 0 50 100 150 200 250 300 350 400 450 500 550 600

Temperature (°F)

ThIs chart shows the ratings for flanges only - the maximum pump operating conditions must also be checked.
Consult the appropriate Tuthill catalog for maximum allowable operating pressures and temperatures, based on pump application
conditions and pump features.
These ratings are based on non-shock pressures.
ANSI data is from ASME/ANSI B16.5 - 1988 (matl group 2.2). Consult this spec for more information.