Está en la página 1de 8

1 FASE 2 FASES 4 HILOS 3 FASES

BUSCAR CONOCIDO HP*746/E*N*FP


A HP
CALCULOS HIDRAULICOS

DATOS
PRESION 3000 PSI Lb/PULG² P
FUERZA 100000 KG 220000 LB F

P= F/A

CALCULO DEL DIAMETRO

A= F/P
A= 73.33 pulg²
A= π * D²/ 4 A = π * r²
A = π * D²/ 4
D= √ (A * 4 / π)
D= 9.7 pulg
D= 10 APROXIMADO

CAUDAL
CILINDROS HIDRAULICOS
DIAMETRO 9.7 pulg
AREA 73.33 pulg²
CARRERA 1.2 metros 47.24 pulg

VOL 3464.57 pulg³

MANGUERAS
LARGO 4 metros 157.48 pulg
DIAMETRO 2 pulg

VOL 494.72 pulg³

BOMBA Y ACCESORIOS 100%


3959.29

V TOTAL 7918.58 pulg³ 129762.32 cm³ 129.76 34.33


gal

CALCULO DE LA VELOCIDAD

Q= V*A

Q= 10 gal/min 37800 cc
A= 73.33 pulg² 473.12 cm²

V= 79.90 cm/min

TIEMPO

RECORRIDO 100 cm
TIEMPO = 1.252 min TIEMPO= RECORRIDO/VELOCIDAD
TIEMPO = 75.1 seg
TIEMPO CICLO= 150.20 seg
CALCULO DE NUMERO DE VARILLAS

M ultimo
K= K= 0.02
Ф * b * d² * f `c
unidades
K=
M ultimo = 4 Ton - m DATO SAP
Ф= 0.85 adimensional
f `c= 210 Kg/cm²
b= 1 ancho cm
d= 1 b-recubrimien cm

1 +/- √ 1 - 2,36 * K
W= W= 1.67 `+
1.18
W= 0.18 `-

W * f `c
δ= cuantificaciòn del acero δ= 0.084 `+
f `y δ= 0.009

f `y= 4200 Kg/cm²

As = δ * b * d area del acero As = 0.084


DISEÑO DEL REFUERZO PARA VIGAS Y CADENAS

Mu (T-m/m) b (cm) d (cm) m Rn δ As


2.118 15 17.4 23.5294118 51.8195564 0.0149769 3.90897161
1.148 20 17.4 23.5294118 21.0654571 0.00535265 1.86272378
4.178 25 17.4 23.5294118 61.3320415 0.01873014 8.14761037
1.574 30 17.4 23.5294118 19.2549532 0.0048627 2.5383289
4.209 35 17.4 23.5294118 44.1336529 0.01228297 7.48032846
1.203 40 17.4 23.5294118 11.0373453 0.00271464 1.88938696
2.254 45 17.4 23.5294118 18.382323 0.00462881 3.62436066

DATOS Cambiar por los obtenidos en el Sap o en ele diseño estructural .

h d = h-recubrimiento fc = 210
fy = 4200
b
Varillas comerciales

o estructural .
CALCULO DE LA CAIDA DE VOLTAJE

K1= 78.74 Cu 1 CABLE AREA CIRCULAR MIL


K1= 118.11 Al 0 105600
1 83690
K2= 1 1 FASE; 2 HILOS F-N 2 66360
K2= 1 1 FASE; 3 HILOS F-N 3 52620
K2= 0.866 3 FASE; 3 HILOS F-F 4 41740
K2= 0.5 3 FASE; 3 HILOS F-N 6 26240
8 16510
10 10300
∆V= K1 * L * I * K2 12 6530
d² 14 4110
16 2580
d²= CIRCULAR MIL CM 18 1620
L= DISTANCIA 250 250000
I= CORRIENTE 300 300000
(∆V/VOLTAJE)*100= CAIDA DE VOLTAJE % 350 350000
400 400000
500 500000
600 600000
700 700000
800 800000
900 900000
00" 133100
000" 167800
0000" 211800

CAIDA DE VOLTAJE PARA EL COBRE

∆V= 6.10 %= 2.77

DATOS
L= 100
I= 150
d²= 000" 167800
K2= 0.866
V= 220

CAIDA DE VOLTAJE PARA EL ALUMINIO

∆V= 2.29 %= 0.52

DATOS
L= 50
I= 60
d²= 00" 133100
K2= 0.86
V= 440