Está en la página 1de 4

CÁLCULO DEL CALOR ÚTIL GANADO DURANTE EL DÍA.

Datos establecidos:

𝐴𝐶 = 2 𝑚2 Área del colector.

𝑈𝐿 =7.26 𝑊 ⁄𝑚2 °𝐶 Coeficiente global de pérdidas de calor

F´=0.94 Eficiencia de la placa.

𝐶𝑃 =4190 J/Kg°C Calor especifico del agua.

Ƭ=0.78 Transmitancia de la cubierta.

α= 0.64 Absortividad ( cobre oxidado)

Ecuaciones a utilizar:

𝑄𝑢 =𝐴𝐶 𝐹𝑅 (𝐼(Ƭα) − 𝑈𝐿 (𝑇𝑒𝑛𝑡 − 𝑇𝑎 ))


DATOS MEDIDOS:

HORA T. ENTRADA RADIACION T. SALIDA T. AMBIENTE t1 t2 t3 m1 m2 m3


09:45 23.6 9.51 30.65 23.7 0 0 0 0 0 0
09:50 24.68 9.8 30.81 23.6 0 0 0 0 0 0
09:55 25.23 9.93 30.91 22.2 0 0 0 0 0 0
10:00 25.32 10 30.24 22.3 0 0 0 0 0 0
10:05 25.37 9.861 29.45 22.9 0 0 0 0 0 0
10:10 25.72 10.03 29.07 23.4 0 0 0 0 0 0
10:15 25.75 10.05 28.12 23 0 0 0 0 0 0
10:20 25.63 10.26 27.63 23.3 0 0 0 0 0 0
10:25 23.47 10.508 42.56 23.1 15.14 15.6 15.23 0.013 0.013 0.013
10:30 23.48 10.46 42.24 22.9 16.52 14.69 15.48 0.012 0.014 0.013
10:35 23.45 6.252 37.63 22.8 17.48 17.49 17.36 0.011 0.011 0.012
10:40 23.32 4.017 31.3 22.5 17.11 17.52 17.46 0.012 0.011 0.011
10:45 23.42 11.12 34.4 22.7 16.21 16.51 16.06 0.012 0.012 0.012
10:50 23.39 7.207 36.71 23.6 16.4 17.04 17.63 0.012 0.012 0.011
10:55 23.42 12.694 39.3 23.6 15.82 16.56 15.1 0.013 0.012 0.013
11:00 23.32 8.57 37.39 22.4 15.45 14.25 14.77 0.013 0.014 0.014
11:05 23.34 7.74 40.44 23.4 15.74 12.79 14.45 0.013 0.016 0.014
11:10 23.38 11.62 35.15 23.7 16.72 16.86 15.72 0.012 0.012 0.013
11:15 23.37 11.42 40.35 24.1 16.14 14.81 14.77 0.012 0.014 0.014
11:20 23.44 10.18 41.11 24.6 14.77 14.83 15.15 0.014 0.013 0.013
11:25 23.44 10.43 40 23.2 16.1 14.8 14.62 0.012 0.014 0.014
11:30 23.47 9.716 40.74 24.1 16.37 16.03 16.03 0.012 0.012 0.012
11:35 23.43 7.36 39.38 23.8 16.6 16 16.56 0.012 0.013 0.012
11:40 23.48 8.007 38.57 22.7 16 15.9 16.85 0.013 0.013 0.012
11:45 23.51 7.739 37.32 23.7 17.97 17.75 17.95 0.011 0.011 0.011
11:50 23.41 7.972 36.55 23.9 18.88 18.42 18.65 0.011 0.011 0.011
11:55 23.4 5.468 35.13 23.3 19.07 19.1 20 0.010 0.010 0.010
12:00 23.39 10.39 40.92 23.3 15.61 14.74 15.61 0.013 0.014 0.013
12:05 23.44 12.26 41.68 23.9 14.21 14.29 13.67 0.014 0.014 0.015
12:10 23.52 12.06 42.44 26.2 15.3 13.65 14.45 0.013 0.015 0.014
DATOS CALCULADOS:

𝑚𝐶 −𝐴 𝑈𝐿 𝐹 𝑈𝐿 (𝑇 −𝑇 ) RADIACION RADIACION I( ) Q UTIL


m(Prom) CAUDAL 𝐴 𝑈𝐿 𝑚𝐶 FR (W/m2) (MJ/m2h) (MJ/m2) (MJ/h)
0 0 0.00000000 0 0 0 -0.726 760.80 2.74 1.37 0.00
0 0 0.00000000 0 0 0 7.8408 784.00 2.82 1.41 0.00
0 0 0.00000000 0 0 0 21.9978 794.40 2.86 1.43 0.00
0 0 0.00000000 0 0 0 21.9252 800.00 2.88 1.44 0.00
0 0 0.00000000 0 0 0 17.9322 788.88 2.84 1.42 0.00
0 0 0.00000000 0 0 0 16.8432 802.40 2.89 1.44 0.00
0 0 0.00000000 0 0 0 19.965 804.00 2.89 1.44 0.00
0 0 0.00000000 0 0 0 16.9158 820.80 2.95 1.48 0.00
0.013 997.62 0.04710715 3.767 -0.250 0.832 2.6862 840.64 3.03 1.51 -1.96
0.013 997.62 0.04647999 3.717 -0.253 0.831 4.2108 836.80 3.01 1.50 -4.50
0.011 997.62 0.04137546 3.309 -0.284 0.818 4.719 500.16 1.80 0.90 -6.25
0.012 997.86 0.04156016 3.324 -0.283 0.819 5.9532 321.36 1.16 0.58 -8.80
0.012 997.62 0.04439193 3.550 -0.265 0.826 5.2272 889.60 3.20 1.60 -5.99
0.012 997.38 0.04244301 3.393 -0.277 0.821 -1.5246 576.56 2.08 1.04 4.20
0.013 997.38 0.04567714 3.652 -0.257 0.829 -1.3068 1015.52 3.66 1.83 5.19
0.014 997.86 0.04872952 3.898 -0.241 0.835 6.6792 685.60 2.47 1.23 -9.10
0.014 997.62 0.05074220 4.058 -0.232 0.839 -0.4356 619.20 2.23 1.11 2.60
0.012 997.38 0.04397132 3.515 -0.267 0.825 -2.3232 929.60 3.35 1.67 6.59
0.013 997.38 0.04744862 3.793 -0.248 0.833 -5.2998 913.60 3.29 1.64 11.56
0.013 997.13 0.04841310 3.870 -0.243 0.835 -8.4216 814.40 2.93 1.46 16.50
0.013 997.62 0.04765233 3.811 -0.247 0.833 1.7424 834.40 3.00 1.50 -0.40
0.012 997.38 0.04472199 3.575 -0.263 0.827 -4.5738 777.28 2.80 1.40 9.87
0.012 997.38 0.04406604 3.523 -0.267 0.825 -2.6862 588.80 2.12 1.06 6.18
0.012 997.86 0.04443275 3.554 -0.264 0.826 5.6628 640.56 2.31 1.15 -7.45
0.011 997.38 0.04035292 3.226 -0.291 0.815 -1.3794 619.12 2.23 1.11 4.06
0.011 997.38 0.03871124 3.095 -0.304 0.811 -3.5574 637.76 2.30 1.15 7.63
0.010 997.62 0.03723929 2.978 -0.316 0.806 0.726 437.44 1.57 0.79 0.10
0.013 997.62 0.04714395 3.770 -0.249 0.832 0.6534 831.20 2.99 1.49 1.40
0.014 997.38 0.05137577 4.107 -0.229 0.840 -3.3396 980.80 3.53 1.76 8.57
0.014 996.86 0.05003480 3.998 -0.235 0.838 -19.4568 964.80 3.47 1.73 35.50
0.013 0.045 3.613 -0.260 0.828 75.49
CALCULO DEL VOLUMEN DE AGUA CALIENTE PRODUCIDO

Variables: