1. SLAB DESIGN
2. BEAM DESIGN
3. COLUMN DESIGN
4. FOOTING DESIGN
5. REINFORCEMENT SCHEDULE
6. STAIR CASE
SLAB DESIGN
3600
3600
2500
C D F H J
3600
K L M N O
2500
P
Q R S T
4000 3500 3500 3500
C D F H J
3600
K L M N O
2500
P
Q R S T
4000 3500 3500 3500
Ast required=638.4914772mm
Nos of Bar dia = 18 mm is 3 , [ Used 3-18 Bar ]
Ast provide=763.02mm
At Mid- Span,
0.5 4.6
+ =area of steel at mid span = [1 1 ]
+ required = 543.2607432mm
Nos of Bar dia = 18 mm is 3 , [ Used 3-18 Bar ]
+ Provide = 763.02mm
As Per IS code Ast min = 0.85 X bd/fy = 178.5 mm [ Hence OK ]
Shear Design :
Shear force at C= 103.088 KN
Shear force at D(left) =145.536 KN
Shear force at D(Right)= 122.038KN
Shear force at F= 116.732KN
Shear force at H(left)= 127.344 KN
Shear force at H(Right)= 122.038KN
Shear force at J= 90.202KN
fs = 0.58 x fy x = 238.9705427 N/mm
( ) max = 35.1 mm
( ) provide = 9.523809524 mm
( ) provide < ( ) max [ OK ]
BEAM-BDLQ
Given section of the beam = 250mm X 450mm
Assuming effective cover = 30 mm
So , d = 450-30 = 420 mm
1 1(3.6+.1)1.75
[ 36001.8+ ].18025
Max self wt load for Slab = 2 3.6
2
= 8.1 KN/m
Self wt of the beam = .45*.25*25= 2.81 KN/m
Live load=1.96 KN/m
Brick unit load of self wt = 0.125(3.2-0.45)*19 =6.53125 KN/m
Factored design load= 1.5*(8.1+1.96+2.81+6.53125)=31 KN/m
Calculation of support moment, (As it is simply support) :
Moment at B, MC= 0 KN-m
Moment at D, MD= -84.816KN-m
Moment at L, MF= -40.90277778KN-m
Moment at Q, MJ= 0 KN-m
Calculation of mid span moment :
Mbd = 73.656KN-m
Mdl = 58.59KN-m
Mlq = 35.52083333Kn-m
Max support moment =-84.816KN-m
Max mid span moment =73.656KN-m
Check for Depth : D=0.133 =313.5879323mm < 420 (OK)
Calculation of area of steel reinforcement (Ast):
At Support,
0.5 4.6
Ast = Area of steel support =
[1 1 ]
Ast required=514.9845972mm
Nos of Bar dia = 16 mm is 3 , [ Used 3-16 Bar ]
Ast provide=602.88mm
At Mid- Span,
0.5 4.6
+ =area of steel at mid span =
[1 1 ]
+ required = 440.2769054mm
Nos of Bar dia = 16 mm is 3 , [ Used 3-16 Bar ]
+ Provide = 602.88mm
As Per IS code Ast min = 0.85 X bd/fy = 178.5 mm [ Hence OK ]
Shear Design :
fs = 0.58 x fy x = 211.7839414N/mm
( ) max = 30.94mm
( ) provide = 8.571428571mm
( ) provide < ( ) max [ OK ]
COLUMN DESIGN-
LOAD CALCULATION ON COLUMN-
LATERAL TIES- the diameter of the tie should not be less than
1
1. 4*20=5 mm
2. 6
Using 6 mm tie
The pitch should not be less than following-
1. Least lateral dimension=350mm
2. 16*20=320mm
3. 300mm
Provide 6mm @ 300mm c/cas double ties
EDGE COLOUMN DESIGN-
Effectively held in one position and restrained against rotation from table no 28 IS456
3000
Slenderness ratio= = =8.57< 12
350
LATERAL TIES- the diameter of the tie should not be less than
1
3. 4*20=5 mm
4. 6
Using 6 mm tie
The pitch should not be less than following-
4. Least lateral dimension=350mm
5. 16*20=320mm
6. 300mm
Provide 6mm @ 300mm c/cas double ties
INTERIOR COLOUMN DESIGN-
Effectively held in one position and restrained against rotation from table no 28 IS456
3000
Slenderness ratio= = 350 =8.57< 12
LATERAL TIES- the diameter of the tie should not be less than
1
5. 4*20=5 mm
6. 6
Using 6 mm tie
The pitch should not be less than following-
7. Least lateral dimension=350mm
8. 16*20=320mm
9. 300mm
Provide 6mm @ 300mm c/cas double ties
FOOTING DESIGN
LOAD CALCULATION :
Wc = 1400 KN ( calculated in column=1392KN MAX )
Assume safe bearing capacity of the soil = 200KN /m
fck = 25 N/mm as M25 grade concrete
fy= 500 N/mm as using Fe 500
Self wt of the footing , Wf= 10% of Wc = 140 KN
Total load on footing = Wc + Wf = 1400+140 =1540 KN
Area of footing = 1540/140 = 7.77 m
Square footing side = 7.77 = 2.77 m = 2.8 m
1.5 1400
Factor soil pressure due to column load , Pu = = 267.86 /
2.8 2.8
2.80.35
Depth of footing d , 2.8 x( d ) x 267.86 . Eq - 1
2
Moment of resistance at critical section =
= 0.46 for M 25
Ru = 0.133fck = 3.325
Mu lim = Ru x b x d = 9352.43d . Eq 4
Over all depth = 560+8+50 = 618 mm=620mm ( As taking clear cover 50 mm and 16 mm dia bar )
Mu = 0.87 x fy x Ast x d x ( 1 - ) ,Putting the value of Mu , fy , d , b , fck
MAIN BAR
ABEGI 250 X 450 2-18 (MID SPAN) 3-18(MID SPAN) 2L-8@140 C/C
4-18(SUPPORT) 3-18(SUPPORT)
CDFHJ 250 X 450 2-18 (MID SPAN) 3-18(MID SPAN) 2L-8@140 C/C
4-18(SUPPORT) 3-18(SUPPORT)
KLMNO 250 X 450 2-18 (MID SPAN) 3-18(MID SPAN) 2L-8@140 C/C
4-18(SUPPORT) 3-18(SUPPORT)
PQRST 250 X 450 2-18 (MID SPAN) 3-18(MID SPAN) 2L-8@140 C/C
4-18(SUPPORT) 3-18(SUPPORT)
ACKP 250 X 450 2-16 (MID SPAN) 3-16(MID SPAN) 2L-8@150 C/C
4-16(SUPPORT) 2-16(SUPPORT)
BDLQ 250 X 450 2-16 (MID SPAN) 3-16(MID SPAN) 2L-8@150 C/C
4-16(SUPPORT) 3-16(SUPPORT)
EFMR 250 X 450 2-16 (MID SPAN) 3-16(MID SPAN) 2L-8@150 C/C
4-16(SUPPORT) 3-16(SUPPORT)
GHNS 250 X 450 2-16 (MID SPAN) 3-16(MID SPAN) 2L-8@150 C/C
4-16(SUPPORT) 3-16(SUPPORT)
IJOT 250 X 450 2-16 (MID SPAN) 3-16(MID SPAN) 2L-8@150 C/C
4-16(SUPPORT) 3-16(SUPPORT)
ALL COLUMN REINFORCE SCHEDULE :
SECTION OF COLUMN = 350 mm x 350mm
PROVIDE 8-20mm BAR
PROVIDE 6 mm @ 300mm C/C double tie
2250 1000
W'
Dead weight on horizontal area = W1 x (R2 T 2 ) 6.56 kN/m2
T
Dead weight of the step is given by W2 = 150 / 2000 x 25 = 1.875 kN/m
Total dead weigh per meter run = 6.56 + 1.88 = 8.43 kN/m
Weight of finshing = 0.04 x 24 = 0.96 kN/m
Live load = 4 kN/m
Total load = 13.39 kN/m
Landing :
Selfweight of the slab = 5.63 kN/m2
Floor finishing = 0.04 x 24 = 0.96 kN/m2
Live Load = 4 kN/m2
Total Load = 10.59 kN/m2
13.39
10.59
Ra 2250 1000 Rb
Reaction at b Rb = 19.39 kN
Reaction at Ra = 21.3 kN
Deflection check :
Lx/d < BV x MF Leff/D = 14 mm BV = 20
Pt = 0.25 % fs = 0.58 fy x Ast (rqd)/ Ast (prov) = 191 N/mm2
From Fig-4 of the code,(page-38) MF= 1.3
Therefore, permissible deflection = BV x MF = 20 x 1.30 = 26 mm
HENCE OK
Distribution reinforcement
Asd= 0.12 x 1000 x 225 /100 = 240 mm2
180
1012,5
3600
S1 S2 S3 S4
C D F H J EXT. BAR
7
STIRRUP
S8
S7
3600
3600
1500 S5 S6
K L M N O
TYP CROSS SEC of BEAM
8 AT MID SPAN
2500
2500
S10 S11 S12
P
240
9
Q R S T 1000 2250
4000 3500 3500 3500 STAIR CASE ALL THR. BAR
4000 3500 3500 3500
EXT. BAR
STIRRUP
ACKP,
BDLQ, 2-16MM(MIDSPAN) 3-16MM(MIDSPAN)
EFMR, 2L-8@150C/C
NAME - RAHUL BARMAN
250X450
GHNS, 4-16MM(SUPPORT) 3-16MM(SUPPORT) ROLL -001410601002
IJOT
DEPT - BE. CONSTRUCTION ENGG.
YEAR - 3RD YR- 2ND SEM
YEAR - 2017
1.ALL DIMENSIONS ARE IN MM
2.NO DIMENSIONS SHALL BE SCALED
1 2 3 4 5
1 2 3 4 5 OUT. ONLY FIGURED DIMENSIONS
ARE TO BE TAKEN.
3.GRADE OF CONCRETE AS PER IS
456 -2000 -M25
2800
2800
6
350 350 350 350 350
6 4. GRADE OF REINFORCEMENT IS
2800 2800
3600
Fe500 (TMT BAR) CONFORMING TO I.S.
350
350
350
350
350
3600
1786-2008
2800
7
7
350 350 350 350 350 2800 5.7. LAP LENGTH FOR R/F BARS
3600
350
350
350
350
350
SHALL BE OF 50 X DIA OF BAR.
3600
2800
8
8
2500
2800
2500
2800
9
9
350 350 350 350 2800
350
350
350
350
4000 3500 3500 3500
4000 3500 3500 3500
ALL COLUMN REINFORCE SCHEDULE :
FOUNDATION LAYOUT PLAN
COLUMN LAYOUT PLAN SECTION OF COLUMN = 350 mm x 350mm
OF COLUMN
CL 16mm @250mm C/C
P.L.
300
350
2800
TIE BEAM
SQUARE FOOTING SECTION= 2800 mm x 2800 mm
350
G.L. CL
X
350
350
16mm @250mm C/C
DEPTH OF THE FOOTING = 620 mm
1500
COLUMN SECTION
(TYP) (TYP)
2800
DETAIL OF FOOTING mm C/C
(TYP.)
620
350
MAIN BAR
12 MM @200 MM C/C
250
DISTRIBUTION BAR
10MM @200MM C/C
150
BEAM
AT
ROOF COLUMN
450
ALTH.BAR
300
EXT.BAR
450
PL LEV.
350
BEAM G.L
300
AT
FLOOR
600mm
2250 1000