Está en la página 1de 1

1 2 2' 18020 3 3' 4 GENERAL

RW2
2310 3500 1500 3505 7200
2555 4645 1- ALL STRUCTURAL DRAWINGS SHALL BE READ IN
CONJUNCTION WITH THE PERTINENT ARCHITECTURAL,
ELECTRICAL,MECHANICAL,SANITARY DRAWINGS & EACH OTHER.

RW2
1335
2- REFER TO ARCHITECTURAL DRAWINGS FOR POSITIONS &
RW2 RW2 DIMENSIONS OF OPENINGS IN R.C WALLS & COORDINATE
A WITH THOSE SHOWN ON STRUCTURAL DRAWINGS .
3- NO BREAKAGE IS ALLOWED IN CONCRETE
AFTER CASTING.

4- DO NOT SCALE DRAWINGS ; ALL DIMENSIONS SHALL BE


3100 READ FROM DRAWINGS OR COMPUTER.

5- UNLESS OTHERWISE INDICATED ON DRAWINGS , ALL


DIMENSIONS ARE IN mm.
BOUNDARY LINE
6- PREPARATION OF THE SITE FOR THE MAIN CONSTRUCTION WILL INCLUDE
B SITE CLEARANCE ,INSTALATION OF DRAINAGE SYSTEM,
DENSIFICATION AND PROOF ROLLING
BOUNDARY LINE DESIGN

1- ISOLATED FOOTING IS RECOMMENDED FOR THIS BUILDING, BEARING C.700KPA


2- DESIGN IS IN ACCORDANCE WITH THE EBCS STANDARD CODE
3- STRUCTURAL MEMBERS ARE DESIGNED TO RESIST THE
TOTAL DEAD LOADS ACTING ON THEM PLUS THE
5000

RW1 RW1 FOLLOWING LIVE LOADS :


ROOFS 0.5KN/M
LIVING AREAS 2.0KN/M
1.20 200 STAIR, BALCONIES 3.0KN/M
150
GROUND FLOOR 5.0KN/M

10 c/c200 CONCRETE & REINFORCED CONCRETE


18730

1200
C 12 c/c150
1- a) REINFORCED CONCRETE SHALL HAVE A MINIMUM
28 DAY CUBE CRUSHING STRENGTH OF 30 N/mm2
WITH MINIMUM CEMENT CONTENT OF 380 Kg/m3.
0.00
b) PLAIN CONCRETE UNDER FOOTINGS, TIE BEAMS ETC,

450

180
SCREEDS SHALL HAVE A MINIMUM 28 DAY CYLINDER
CRUSHING STRENGTH OF 25 N/mm2 WITH MINIMUM
CEMENT CONTENT OF 250 Kg/m3.
A A
10 c/c200
c) MAXIMUM WATER CEMENT RATIO IS 0.43

12c/c150 - 4770
RW1 RW1
5300

RC RETAINING WALL
2- ALL REINFORCED CONCRETE SHALL BE WELL VIBRATED.

4470
12 c/c150 3- ORDINARY PORTLAND CEMENT ( ASTM C150 LATEST
REVISION, TYPE ll ) SHALL BE USED THROUGH OUT.

200 4- ALL REINFORCING STEEL BARS SHALL BE

2880
HAVING A MINIMUM YIELD STRENGTH OF 400 N/mm2 DETAILED
IN ACCORDANCE TO LATEST EBCS CODES.

D 5- LAP LENGTHS OF REINFORCEMENT BARS SHALL BE AS


SHOWN ON THE DRAWINGS BUT NOT LESS THAN :
40 BARS DIA. FOR DEFORMED BARS
50 BARS DIA. FOR PLAIN BARS.
RC RETAINING WALL 6- MINIMUM CLEAR CONCRETE COVER TO STEEL
12 c/c150
-3.06 REINFORCEMENT SHALL BE AS SHOWN ON DRAWINGS.
3995

WHERE NOT SHOWN IT SHALL BE AS FOLLOWS :

250
50 mm FOR FOUNDATIONS IN CONTACT WITH SOIL,
150 OR WATER PROOFING.
BOUNDARY LINE BOUNDARY LINE VAR.
10 c/c200
25 mm IN WALLS, COLUMNS
15 mm SLABS, RIBS, EMBEDDED BEAMS, WALLS AND
Typical Retaining Wall COLUMNS NOT EXPOSED TO EARTH.
D' SECTION RW2 - RW2 7- PROVIDE MINIMUM 0.002 TIMES THE CROSS SECTIONAL
SC 1:25 AREA IN SLABS AS DISTRIBUTION STEEL WHERE REQUIRED.
BOUNDARY RC WALL LAYOUT 8- INCASE OF UNSTABLE DEEP EXCAVATION, THE BOUNDARY
SC 1:50 RETAINING WALL TO BE CONSTRUCTED AFTER EXCAVATION

1 2 3 4 0.00
150
0.00 IS COMPLETED AND BEFORE OR ALONG WITH OTHER STRUCTURES.

180
15710
SKYLINE Consultants
3500 5010 7200
10 c/c200 Consulting Architects & Engineers plc

12c/c150 - 3765
e.mail - ethioskyline@yohoo.com
0.00 0.00
Tel. (office)0116-62 95 02,(mob) 0911- 25 20 43

3465
12 c/c150
1530

Var.
Project:
-1.53 200

2880
PARKING ENTRANCE
3060

(ROAD LEVEL) MIXED APARTMENT BUILDING


Location: ADDIS ABABA, NIFAS SILK LAFTO SUB CITY
5160

Var.
-3.06 WOREDA 03 PLOT CODE NO: MIX-000-11524

Var. Owner:
Ato Metsihafe Mekbib
3630

Des By ZERIHUN YILMA PPST/147


2000

-3.06
Title:

180
SHORING LAYOUT & SECTION

450
-5.06
Cad file: D/Skyline/Metsihafe Drawn By: Checked By:
150 MIKIYAS G. ZERIHUN YILMA PPST/147

Typical Retaining Wall


SECTION A - A SECTION RW1 - RW1
Scale: 1:50/ 1:25 Project No.

SC 1:50
SC 1:25 Date:MAR. 2017
Dwg No. ST-01/15