Está en la página 1de 11

CERTIFIED

See the difference


CARYAIRE Air Treatment Units tempt you to admire...

The smooth aesthetics, the contemporary looks and

rust free construction makes it ideal for most

applications such as Shopping Malls, Hotels, Office

Complexes, Software Industry, Electronics Industry,


CERTIFIED
Pharmaceutical Industry, Clean Room Applications

and many more.

Hear the difference


The performance that can be experienced, not

heard.

Vibration free fan assembly & air tight

construction reduces noise levels

considerably for an acoustic comfort.

Smell the difference


The air of excellence is our commitment.

Optimum solutions for hygiene and desired

indoor air quality are delivered by strict

adherence to international standards, constant

innovation and adoption of new technologies.

Experience the difference


The difference which you will notice when you use

our product.

Or ask our ever growing family of over 25,000 customers in

India & abroad.

2 3
Construction
Construction
Condensate Drain
Condensate Drain PanPan
Frame Work
Frame Work The frame work is made of anticorodal hollow Drain pan is made of aluminium with dual slope
extruded aluminium profile, held together by to facilitate immediate discharge of condensate.
special nylon thermoplastic self extinguishing Specially designed drain pan with all round edges
3-legged joints that ensures perfect alignment & allow complete cleaning & avoid microbial growth
rigidity of the whole structure.
as per ASHRAE 62-1999.

Problem of excessive condensation on structural


Drain pan in SS-304 construction is also available
frame is addressed by providing high
as option.
performance thermal bridge profile.

Anodised profiles & screw less snap fixing


profiles are also available as an option. Base Frame
Base Frame
Panels
Panels Base frame is made of galvanised steel with die
cast aluminium joints having lifting holes.
Double skin 25/43 mm panels injected with
Extruded aluminium base is available as an
environment friendly CFC & HFC free, self
extinguishing PUF as per ASTM D 3014. A uniform option.
3
density of 38-40 Kg/m ensures low thermal
conductivity & robust construction.

For high humid ambient conditions, panels with


thermal bridges can be provided on request.

Various options such as pre-coated coloured galvanised sheets, plain galvanised sheets,
aluminium & SS 304 & SS 316 sheets in various thicknesses are available for inner & outer Hinges
Hinges &&Locks
Locks
skin of double skin panels.

Glass wool or mineral wool insulation is also available Access doors are provided with hinges &
as an option. locks made of self extinguishing nylon for
perfect air tightness.

Gasket
Gasket
Multi finned gasket slided in built-in grooves in the
structural profile of the unit ensures air-tight
construction.

For special applications, food grade gasket as per BS EN-71 Part 3 : 1995 can be provided
on request.
5
4
Components
Components
Air Treatment Section
Air Treatment Section
Fan Section
Fan Section Computer selected high efficiency copper tube,
aluminium finned Water & DX coils
Highly energy efficient, AMCA certified, fans
manufactured in technical association with
with forward / backward curved construction
Heat Trans Corporation, USA are provided for
are available for medium to high static pressure
cooling / heating in a single stac, upto 12 rows
applications. The electric motor is totally
deep.
enclosed type with an IP 55 or 54 protection,
Class F insulation.

Direct drive plug fans with inverter drive are


also available on request.

Fan & motor is mounted on a common extruded


aluminium channel base by using anti-vibration
isolators and self extinguishing fabric flexible
connection tested to UL -214 and confirms to Each coil is pressure tested at
NFPA 90A & NFPA 90B standards. Thus ensuring 2059 kPa with air under water for
low operating noise & vibration. trouble free operations.

Electrically interlocked limit switch trips the


fan & motor assembly immediately on door
opening.
The wire
guard on
access door
offers an
additional
safety.

Copper fins, anti-corrosive coating on fins for coastal


applications and side plates in SS construction are
View port is provided as a standard feature. Weather proof
also available as option.
lamp is also available on request.

Steam or spray humidifier section can also be


provided as an integral part of the unit.

7
6
Components
Components Options
Options
4 Sound attenuation section for low noise
applications.

Air ControlDevice
Air Control Device 4 Humidification section with wet deck 100 mm or
200 mm / spray type with inlet vanes & mist
eliminator / steam humidifier & pan type humidifier
Low leakage air control devices are made of extruded for critical applications.

aluminium aerofoil design profiles, driven with 4 Cross flow plate type, wheel type heat recovery and
polycarbonate gear chain for low torque operation. heat pipe can be supplied as an integral part of the
unit for energy conservation.
GI / SS construction is also available as an option.
4 Face & bypass / bypass damper section.
4 Drift eliminators in PVC / SS / Aluminium / G.I.
4 Condensate drain pump for underground installations.
4 Electric heater section for heating / humidity control.

Accessories
Accessories
4 Micro processor control panel with required field sensors
duly wired to the unit.

Filters
Filters 4
4
Variable frequency drive with bypass arrangement.
Contoured aluminum roof for outdoor application.
Single / multi stage filtration is offered to suit 4 Intake louvre with bird screen for fresh air intake.
different applications. A complete range of 4 Outlet cowl with bird screen for exhaust unit.
filters as per ASHRAE & EUROVENT standards
4 Fire retardent flexible joints for Inlet & outlet of the unit.
are available.

Human Safety Devices


Pressure measurement ports across fine
filters are provided as a standard feature.

Human Safety Devices


4 Electrically interlocked fan section access door
(without wiring).
4 Wire guard for fan section.
4 Earth connection of fan & motor base assembly.
4 Nylon caps for all projected screws.

9
8
Quick Selection Chart Average Pressure Drop of ATU Components
The shown pressure drop values are
average values. Exact values can be
Model Air velocity through Over all cross-flow dimensions (without base)
2.0 2.5 3.0 determined with computer selection
CCTU unit components (m/s) H x W (mm) and type of components used.

010 640 x 940 2.0 2.5 3.0

20 Heating Coil 0 Heating Coil


6R 1R
12 FPI 10 FPI
5R PRESSURE DROP SUMMARY
015 880 x 940 2.0 2.5 3.0 15 5 2R

3R
4R
4R
SELECTED UNIT
10 3R 10 COMPONENTS
5R

020 880 x 940 2.0 2.5 3.0 2R 6R OTHER COMONENTS


5 15
1R EXTERNAL REQUIRED
STATIC PRESSURE
0 20
FAN DYAMIC PRESSURE
025 880 x 1240 2.0 2.5 3.0
TOTAL PRESSURE FOR
FAN SELECTION

030 880 x 1240 2.0 2.5 3.0 DIRTY


Bag Type Fine Filter
0
20 Heating Coil
1R
EU-7 Fins
2R
10 CLEAN 5 8 FPI
3R
035 940 x 1540 2.0 2.5 3.0
4R
10 3
5R Sound
6R Attenuator
15 2 1500 - Length mm -
040 940 x 1540 2.0 2.5 3.0
DIRTY 900
20 Fine Filter 1
EU-9
060 1200 x 1540 2.0 2.5 3.0 10
CLEAN
0
0 Wet Deck
100 Humidifier Medium
5 - Thicknesses mm -
080 1450 x 1540 2.0 2.5 3.0 200
10

DIRTY 30 Activated
20 Fine Filter Carbon Filter
100 1520 x 1820 2.0 2.5 3.0
EU-7 20
10 CLEAN

Pressure Drop in mm wg
5 Cooling Coil 10
120 1520 x 2120 2.0 2.5 3.0 3R
4R
12 FPI
20
5R
6R
35
150 1780 x 2200 2.0 2.5 3.0
DIRTY
8R
10 Bag Type Pre-filter 50 60 Multi-pleat
8 EU-3/4 Absolute Filter
DIRTY
6 50 EU-13
CLEAN
180 2080 x 2200 2.0 2.5 3.0
4
40

5 Cooling Coil
3R
200 1840 x 2780 2.0 2.5 3.0 4R 10 FPI 30
20 5R
6R CLEAN
EU-3/4 Synthetic 20
DIRTY
10 Prefilter 35
240 2080 x 2780 2.0 2.5 3.0 8R
10
6 50
CLEAN

300 2180 x 3420 2.0 2.5 3.0 2

5 Fan
5 Cooling Coil 2.5 Equilizer Baffle
350 2450 x 3420 2.0 2.5 3.0 3R
4R 8 FPI 0
5R
20
2 Inlet Section 6R
8R
420 2550 x 4100 2.0 2.5 3.0 1 35

10 Supply Air
Plenum
0 1000 2000 3000 4000 8000 12000 18000 24000 35000 54000 4 Intake Louvre 1 Fan 5
3 2 Chamber
500 1500 2500 3500 6000 10000 15000 20000 30000 42000 Pitch 50
2 3 0
1
Air Volume in CFM 2.0 2.5 3.0

For Base add 100 mm upto Model CCTU 180 & add 140 mm for Model CCTU 200 & above Air Velocity (m/s)

11
10
Dimensions
Belt Driven Fan Section Fan Outlet Position Duct Connection Inlet Section Mixing Section Double Mixing Section Plenum

ExF CxD CxD

a
1 2

CxD

CxD
L 42 3 4

130 130 80
P L1 P L2 L3 On
Request
b 5 6

Plain Filter Bag Filter Section Fine / HEPA Heating Coil Section Cooling Coil Section
Motor Frame Sizes Section Filter Section
Fan
Fan <112 132 160-180 200 225 a b
Outlet
Sizes
Position Fan Casing Length L (mm) mm mm

7-7 1-6 840 208 232


9-9 1-6 940 262 298
10-10 1-6 940 289 331
12-12 1-6 1040 341 395
15-15 1-6 1120 404 471
Model
Fan Sizes 18-18 1280
CCTU 1-6 1240 483 557
010 7-7 160 180 200 160 1-6 840 205 205 400
015 9-9 200 225 240 550 Min. 700 305 160 1-2 RD 400 < CCTU 080
180 1-6 880 229 229
020 10-10 225 250 280 680 300 3-6 RD 440 CCTU 080-150
200 1-6 900 940 256 256
800 480 CCTU 180-240
025 12-12 250 280 315 225 1-6 940 980 288 288 520 > CCTU 240
030 12-12 280 315 250 1-6 980 1020 322 322
035 15-15 315 355 280 1-6 1020 1060 361 361
040 15-15 315 355 315 1-6 1060 1100 404 404
060 18-18 400 450 355 1-6 1160 1200 453 453
080 450 500 560 400 1-6 1240 1280 507 507
100 500 560 630 Electric Wet Deck Sound Attentuator Section Cross Flow Plate Type Cross Flow Heat Recovery
1-2 1280 1320 1480
450 569 569 Heater Section Humidifier Section Heat Recovery Section Wheel Section
120 560 630 3-6 1320 1360 1520
150 630 710 1-2 1340 1380 1520
500 638 638
180 710 800 900 3-6 1420 1460 1600
200 710 800 1-2 1460 1500 1640
560 715 715
240 800 900 3-6 1520 1560 1700
300 900 1-2 1560 1600 1720
630 801 801
350 1000 3-6 1640 1680 1840
420 1000 1-2 1720 1880 1980 1980
710 898 898
3-6 1840 2000 2100 2100
1-2 1886 2000 2100 2100 450 L4 900 L5 L6
800 1007 1050
3-6 2080 2200 2300 2300 1500

1-2 2000 2160 2260 2260


900 1130 1170
3-6 2246 2400 2500 2500
1-2 2160 2280 2380 2380
1000 1267 1310
3-6 2400 2560 2660 2660 13
12
Air Treatment Unit Arrangement Example Heat Recovery Unit Arrangement Example
CCTU - 150 CCHU - 150
L7

Divided for Transportation Divided for Transportation

Fan 630 Fan 630 Fan 630

H2 = 1680 x 2540
1780 x 2200

GxH
Fan 630

H1 = 1780 x 2540
42 1600 40 1500 42 42 440 40 160 40 1600 42

GxH
5588

42 1600 42 42 1400 42 42 440 40 1600 42

Coil
Model
P C D E F L1 L2 L3 L4 L5 L6 Filter Grid
CCTU Fin Fin
5332
Height Length
010 42 226 600 226 200 360 400 800 440 640 1000 317 610 0A+1B
015 42 226 700 226 300 360 400 800 440 500 1040 508 584 1A+0B
020 42 226 800 226 300 360 400 800 440 500 1080 635 610 1A+0B
025 42 328 820 226 400 400 480 920 440 960 1080 508 914 1A+1B
030 42 328 1120 226 400 400 480 920 440 960 1080 635 914 1A+1B Coil
Model
P H1 H2 W L7 G H Filter Grid Wheel Dia
035 42 328 1220 328 500 400 480 920 440 960 1120 571 1219 2A+0B CCHU Fin Fin
Height Length
040 42 328 1420 328 500 400 480 920 440 960 1120 635 1219 2A+0B
015 42 880 800 1040 1000 328 400 20 22 1A + 0B 700
060 42 430 1420 328 600 480 600 1120 440 1120 1160 952 1219 2A+2B
020 42 880 800 1140 1000 328 600 22.5 26 1A + 0B 800
080 42 430 1420 328 800 480 600 1120 440 1280 1160 1206 1219 4A+0B
025 42 880 800 1240 1000 430 600 22.5 32 1A + 1B 900
100 42 532 1700 430 700 560 700 1300 440 1440 1280 1270 1473 4A+2B
030 42 880 800 1340 1000 430 700 22.5 39 1A + 1B 1000
120 42 532 2000 430 900 560 700 1300 440 1440 1280 1270 1778 6A+0B
035 42 940 940 1440 1000 430 700 25 41 2A + 0B 1100
150 42 634 2080 532 900 560 800 1500 440 1600 1400 1524 1829 6A+3B
040 42 940 940 1540 1000 430 800 25 46 2A + 0B 1200
1x889
180 42 736 2080 634 900 720 920 1720 800 1760 1400 1854 9A+0B
1x952 060 42 1200 1200 1740 1000 430 1200 37.5 46 2A + 2B 1400
200 42 636 2660 634 1100 880 920 1720 800 1920 1524 2438 8A+4B 080 42 1340 1340 1940 1000 532 1350 37.5 62 3A + 3B 1600
1x889 100 42 1520 1420 2120 1060 634 1400 47.5 61 4A + 2B 1800
240 42 736 2660 736 1100 880 920 1720 800 1920 2438 12A+0B
1x952
120 42 1520 1420 2320 1060 636 1700 47.5 73 6A + 0B 1900/2000
300 62 736 3260 736 1300 880 920 1720 800 2280 2x952 3048 15A+0B
150 42 1780 1680 2540 1060 636 2000 50 87 6A + 3B 2200
350 62 836 2800 736 1400 880 1200 2280 800 2280 2x1080 3048 15A+5B
420 62 1042 3300 1042 1500 880 1200 2280 800 2630 2x1143 2x1702 18A+6B 1. All dimensions are in mm.
2. Filter Size A - 592 x 592 x 50 mm
B - 292 x 592 x 50 mm
1. All dimensions are in mm.
3. CARYAIRE reserves the right for technical modifications.
2. Filter Size A - 592 x 592 x 50 mm
4. The indicated dimensions are not binding.
B - 292 x 592 x 50 mm
5. For unit base add 100 mm to unit height.
3. CARYAIRE reserves the right for technical modifications.
6. For fan section length refer page no. 12.
4. The indicated dimensions are not binding.

Access Door Access Door

15
14
Double Skin Vertical
Double Skin VerticalFloor
FloorMounted
MountedAirAirTreatment
Treatment
UnitUnit Double
Double Skin HorizontalCeiling
Skin Horizontal CeilingSuspended
SuspendedAirAirTreatment
Treatment Unit
Unit
Capacity Range 1500 CFM - 8000 CFM Capacity Range 1500 CFM - 8000 CFM

Selection Table Selection Table

Overall Dimension Standard Overall Dimension Standard


Model Air
(Fan, Coil, Pre Filter) Other Details Model Air
(Fan, Coil, Pre Filter) Other Details
Coil Size Coil Size
Capacity Capacity

Height Width Depth FH FL Fan Motor Unit Outlet Outlet Filter Height Width Depth FH FL Fan Motor Unit Outlet Outlet Filter
Model Rating HxW Velocity Area Model Rating HxW Velocity Area
CAFU CFM CAFU CFM
mm mm mm mm mm KW mm m/s Sqm mm mm mm mm mm KW mm m/s Sqm
Belt Drive Belt Drive
15 BV 1500 1220 1080 600 381 762 AT 9 - 9 S 0.55 262 x 298 9.1 0.46 15 BH 1500 570 1080 1160 381 762 AT 9 - 9 S 0.55 262 x 298 9.1 0.46
20 BV 2000 1320 1180 680 445 864 AT 10 - 10 S 0.75 289 x 331 9.9 0.46 20 BH 2000 620 1180 1200 445 864 AT 10 - 10 S 0.75 289 x 331 9.9 0.46
30 BV 3000 1320 1580 680 445 1270 AT 9 - 9 G2L 1.1 262 x 840 9.1 0.69 30 BH 3000 590 1580 1200 445 1270 AT 9 - 9 G2L 1.1 262 x 840 9.1 0.69
40 BV 4000 1320 2040 680 445 1727 AT 10 - 10 G2L 1.5 289 x 926 9.9 0.91 40 BH 4000 620 2040 1260 445 1727 AT 10 - 10 G2L 1.5 289 x 926 9.9 0.91
60 BV 6000 1550 2140 800 635 1828 AT 12 - 12 G2L 2.2 341 x 1114 10.5 1.36 60 BH 6000 780 2140 1300 635 1828 AT 12 - 12 G2L 2.2 341 x 1114 10.5 1.36
80 BV 8000 1740 2340 900 762 2032 AT 15 - 15 G2L 3.7 404 x 1326 9.9 1.76 80 BH 8000 900 2340 1460 762 2032 AT 15 - 15 G2L 3.7 404 x 1326 9.9 1.76
Direct Drive Direct Drive
15 DV 1500 1220 1080 600 381 762 9/9 0.37/1f/4P 262x298 9.1 0.466 15 DH 1500 570 1080 900 381 762 9/9 0.37/1f/4P 262x298 9.1 0.466
20 DV 2000 1320 1180 680 445 864 10/10 0.55/1f/4P 289x331 9.9 0.466 20 DH 2000 620 1180 960 445 864 10/10 0.55/1f/4P 289x331 9.9 0.466
30 DV 3000 1320 1580 680 445 1270 12/12 0.736/1f/6P 341x395 10.5 0.699 30 DH 3000 590 1580 1100 445 1270 12/12 0.736/1f/6P 341x395 10.5 0.699
40 DV 4000 1320 2040 680 445 1727 2 x 10/10 2x0.55/1f/4P 289x926 9.9 0.915 40 DH 4000 620 2080 960 445 1727 2 x 10/10 2x0.55/1f/4P 289x926 9.9 0.915
60 DV 6000 1550 2140 800 635 1828 2 x 12/12 2x0.736/1f/6P 341x1114 10.5 1.36 60 DH 6000 790 2140 1100 635 1828 2 x 12/12 2x0.736/1f/6P 341x1114 10.5 1.36
The above table corresponds to following assumptions : The above table corresponds to following assumptions :
a. Coil RD upto 6 RD a. Coil RD upto 6 RD
b. Fan as bottom horizontal discharge. b. Fan as bottom horizontal discharge.
c. Drain connection 25mm BSP c. Drain connection 25mm BSP
d. Static Pressure : 32mm wg d. Static Pressure : 32mm wg

17
16
Double Skin Ventilation
VentilationUnit
Unit
Double Skin
Capacity Range 1000 CFM - 35000 CFM Our Customers
Our Customers
Pharmaceuticals IT Industry
! Cipla Ltd., Goa ! Dell International Services - Bangalore
! Colgate Palmolive, Mumbai ! Digital India Ltd. - Bangalore
! Dr. Reddys Lab, Hyderabad ! Hewlett Packard - Bangalore
! Hariri Trading - Syria ! Hughes Software - Bangalore
! Lupin Laboratories , Goa ! I-Flex Solutions Ltd. - Bangalore
! Pfizer Ltd., Mumbai ! Motorola India Electronic Pvt. Ltd. - Bangalore
! Rhone Pouleng, Mumbai ! Microsoft - Hyderabad
! Ranbaxy Ltd., Nasik, Gurgaon, Mohali ! Nucleus Software - Noida
! Serum Institute of India Ltd., Pune ! Oracle Software - Bangalore
! Wockhardt Ltd., Aurangabad, Daman ! Sonata Software - Bangalore
! Warner Lambert, Bangalore ! Wipro Limited - Bangalore

Selection Table Industrial Application Commercial Buildings


! Becton Dickinson India Pvt. Ltd. ! Embassy of United States of America, New Delhi

Model Air Overall Dimension Other Details


! British Tabacco Co. - Dhaka ! Embassy of Greece, Qatar, UAE, New Delhi
Capacity ! Ericsson Ltd., Mumbai ! Aeronautic Development Authority - Bangalore
Length Width Height Fan Motor Unit Outlet Outlet Filter
Velocity
! General Motors India Pvt. Ltd. - Bangalore ! Andhra Pradesh Secretariat - Hyderabad
Size Rating HxW Grid
CCVU CFM
mm mm mm KW mm m/s ! G E Medicals and X-Rays Ltd. ! Ansals Plaza - New Delhi
010 1000 800 600 500 7-7 0.75 208 x 232 9.8 0A+1B ! Hindustan Lever Ltd. ! Big Kidskemp - Bangalore
015 1500 880 720 560 9-9 1.1 262 x 298 9.1 0A+1B
! Owens Corning India Ltd., Mumbai ! DRDO - Jagdalpur
020 2000 920 800 620 10-10 1.1 289 x 331 9.9 0A+1B
! Moser Baer Ltd., NOIDA ! Hongkong Bank - Mumbai
030 3000 980 840 700 12-12 1.5 341 x 395 10.5 1A+0B
040 4000 1120 1000 780 15-15 2.2 404 x 471 9.9 1A+0B
! Reserve Bank of India - Mysore & Salboni ! ISRO - Cochin
060 6000 1240 1180 1000 18-18 3.7 478 x 557 10.6 1A+1B ! Timken Engineering and Research India Pvt. Ltd. - Bangalore ! MEEPE - Colombo
080 8000 1440 1360 1240 500 5.5 638 x 680 9.3 2A+0B ! Toyota Kirloskar Auto Parts Pvt. Ltd. - Bangalore ! State Bank of India - Mumbai
100 10000 1500 1500 1320 560 5.5 715 x 760 9.2 2A+2B
150 15000 1600 1650 1480 630 7.5 801 x 840 11.0 4A+0B
180 18000 1880 1820 1680 710 7.5 898 x 940 10.5 4A+2B
240 24000 2000 2000 1840 800 9.3 1007 x 1050 11.2 6A+0B
Hotels Hospitals
300 30000 2160 2240 2040 900 11.0 1130 x 1170 11.1 9A+0B ! Hyatt Regency - Goa ! AIIMS - New Delhi
350 35000 2300 2500 2200 1000 15.0 1267 x 1310 10.3 12A+0B
! Le - Meridian - Chennai ! ASIRI Medical Services - Colombo
1. Add 100 mm for unit base/leg.
(Unit upto 60 model are with legs & above 60 are with steel base) ! Leela Kempinsky - Mumbai ! Escorts Heart Centre - New Delhi
2. Isolators incorporated for model above CCVU 60.
3. For 43 mm panels add 40 mm on overall dimensions. ! Mcdonalds - Mumbai ! G. K. Bhuj Hospital, Bhuj
4. Static Pressure : 50mm wg.
5. Filter Sizes : A - 592 x 592 x 100 mm ! The Oberoi - New Delhi, Mumbai, Bangalore ! Gokulam Hospital, Bangalore
B - 292 x 592 x 100 mm
! Pizza Hut - Jaipur ! Max Hospital - New Delhi
! Sahara Star - Mumbai ! Safderjung Hospital - New Delhi
! Taj Group of Hotel - New Delhi ! SJIC Hospital - Bangalore
! The Trident - Chennai, Jaipur ! Usha Malapudi Cardiac Centre, Hyderabad
! Windsor Manor & Sheraton Towers - Bangalore ! Wockhardt Hospital - Mumbai 19
18
State
State ofofThe
theArtArtManufacturing
ManufacturinFacilities
g Facilities

Spread over 1,00,000 sq feet

all our state of the art

manufacturing plants

are equipped to

deliver you the best.

sales@perfectimpact.net
We dont manufacture products...

We create them...
CARYAIRE reserves the right for technical modifications without notice.

TM

C A R YA I R E
Total Climate and Air Management Company
CA/01/06/2004/1500

Caryaire Equipments India Pvt. Ltd.


Head Office : A-10, Sector-59, NOIDA - 201 301 U.P. (India) Tel.: + 91 120 2580553, 54, 55, 56 Fax : + 91 120 2580557
E-mail : caryaire@vsnl.com / sales@caryaire.com WEBSITE : http://www.caryaire.com
Export Division : Tel. : +91-120-2589092 Fax : +91-120-2589093 E-mail : export@caryaire.com
MUMBAI Tel. : +91 22 56902056, 56902057 Fax : +91 22 28547314 BANGALORE Tel. : +91 80 51152544 Fax : +91 80 51152545
USA Tel. : 001 704 595 9116 E-mail : managerightinc@hotmail.com

También podría gustarte