Está en la página 1de 3

Dimetro interno

plg
Tubera 2" Cdula 40
2.067

e/D= 0.0009
D (m)= 0.0525 gc = 9.81 kg m/kg-f s2
D (cm)= 5.25 D/SL = 0.000341292
Q (m3/s) 0.10 v2/2gc = 108.75 kg-f m/kg
Q (cm3/s) 100,000.00 SF= 6,085.97 kg-f m/kg
Area (cm2)= 21.65
v (m/s)= 46.19
v (cm/s)= 4,619.14
r (g/cm3)= 0.882
m (g/cm s)= 0.0065
NRe= 3.29E+06
f= 0.0191

Dispositivo L/D L (m) Unidades L (m) Total


Codo 90 30 1.575 2 3.150108
Vlvula de
compuerta 13 0.683 1 0.6825234
Tubera 150.000 150.000
Total 153.833

v1 (m/s) = 0 P1 = 0
v2 (m/s) = 46.19 P1/r = 0
z1 (m) = 0 P2 (kN/m2)= 500 72.5 psia
z2 (m) = 100 P2 (kg-f/m2)= 50,985.00
P2/r (kg-f m/kg)= 57.81

v12/2gc (m/s) = 0 DP/r (kg-f m/kg)= 57.81


v22/2gc (m/s) = 108.75
Dv2/2gc (m/s) = 108.75
Dz2g/gc (kg-f m/kg) = 100

-Wf (kg-f m/kg)= 6,352.53


Flujo msico (kg/s)= 88.2
Potencia (kg-f/s)= 560,292.98
1 Kw = 1000 kg-f m/s
Potencia (Kw) = 560
Potencia (HP) = 751
Dimetro
interno plg
Tubera 3" Cdula 40 3.068 Densidad
286.1111111111
e/D= 0.0006 55 F = 13.11 C
D (m)= 0.0779
D (cm)= 7.79 10 C 0.9997
Q (pies3/min)= 12.00 25 C 0.9971
Q (cm3/s) 5,663.37 Cambio 0.00017333
Area (cm2)= 47.69 13 C 0.99918
v (m/s)= 1.19
v (cm/s)= 118.74
r (g/cm3)= 0.99918
m (g/cm s) 55 F= 0.0122
NRe= 7.58E+04
f= 0.0215

Dispositivo L/D L (m) Unidades L (m) Total gc = 9.81 kg m/kg-f s2


Codo 90 30 2.338 8 18.702528 D/SL = 0.00048967
Vlvula de compuerta
abierta 13 1.013 4 4.0522144 v2/2gc = 0.07 kg-f m/kg
Tubera 121.920 121.920 SF= 3.16 kg-f m/kg
Total 159.142

v1 (m/s) = 0 P1 = 0.0
v2 (m/s) = 1.19 P1/r = 0.0
z1 (m) = 0 P2 (psi)= 15.0
z2 (m) = 18.288 P2 (kg-f/m2)= 1.020
P2/r (kg-f m/kg)= 0.00102

v12/2gc (m/s) = 0 DP/r (kg-f m/kg)= 0.00102


v22/2gc (m/s) = 0.07
Dv2/2gc (m/s) = 0.07
Dz2g/gc (kg-f m/kg) = 18.288

-Wf (kg-f m/kg)= 21.52


Flujo msico (kg/s)= 5.66
Potencia (kg-f/s)= 121.75
1 Kw = 1000 kg-f m/s
Potencia (Kw) = 0.1218
Potencia (HP) = 0.1632
Eficiencia= 40%
Potencia elctrica (Kw)= 0.304
Potencia elctrica (HP)= 0.408

También podría gustarte