Está en la página 1de 6

Time Flow Basin Pillar Tap - Push Button

TFC745
The time flow pillar tap when
operated provides a flow of water
for the duration of the delay
specified. The time delay is preset
and available in 3, 7 or 15 seconds
allowing the hands to be adequately
washed under the water stream
while avoiding the concerns of cross
contamination by having to turn the
tap off manually afterwards. The shut
off delay avoids the need to hold the
tap on as is necessary with simple
spring loaded type taps.
In disabled/accessible wash rooms
the lever action option provides a
long lever to assist in the operation
of the tap.

Product Code
TFC745 - Time Flow Basin Pillar Tap - Push Button - 15 seconds
TFC745P - Time Flow Basin Pillar Tap - Push Button - 7 seconds
TFC745P3 - Time Flow Basin Pillar Tap - Button Action - 3 seconds
TFC745L15 - Time Flow Basin Pillar Tap - Lever Action - 15 seconds
TFC745L - Time Flow Basin Pillar Tap - Lever Action - 7 seconds
TFC745L3 - Time Flow Basin Pillar Tap - Lever Action - 3 seconds

Technical Information
Inlet Connection 15 mm () BSP

Working Pressure Range 100 - 500 kPa

Recommended Pressure 350 kPa

Flow Rate 8 l/minute

Operating 0-85C
Temperature Range
Recommended 5-30C
Temperature Range
80

50

22 HOLE
20

1/2" BSP

1/2" BSP

45

115

REV DATE CN AMMENDMENTS APP GENERAL NOTES:

Enware tap ware must be installed in accordance TIMED FLOW


TOLERANCE EXCEPT WHERE STATED:
with the provisions of AS/NZS 3500. Installations not
complying with AS/NZS 3500 may void the product
and performance warranty provisions.
ENWARE RESERVES THE RIGHT TO AMEND PRODUCT
SPECIFICATIONS AND DESIGNS WITHOUT NOTICE.

Version: MAY10

Call 1300 369 279


www.enware.com
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: +61 2 9525 9511 Fax: +61 2 9525 9536
1. INSTALLATION INSTRUCTIONS

Before proceeding with installation ensure all operating & dimensional specifications are suitable for the intended installation.

Ensure all supply lines are flushed thoroughly to remove debris prior to the installation of this product. Strainers (60 mesh) are
recommended if debris is an ongoing problem. A Pressure reduction valve may be required to comply with recommended maximum
supply pressure and/or balanced pressure requirements.
It is recommended that an isolation valve is installed prior to the time flow bib tap and that this is easily accessible.

The time flow pillar tap requires a cold or premixed warm water supply. It is recommended that an Aquablend thermostatic mixing
valve be used if warm water temperature settings are critical.* (Refer to Heated Water Services below)

Plumbing installations must comply with AS/NZS3500 and relevant State and Local government/water authority requirements

1.1 INSTALLATION COMPLIANCE REQUIREMENTS


Enware products must be installed in accordance with AS/NZS 3500 Plumbing and Drainage, the Plumbing Code
of Australia as well as imposed Local and State / Territory Legislative requirements and the manufacturers instructions.
The following clauses must be observed for a compliant installation and correct operation of Enware tapware.

Water Services * Heated Water Services


Plumbing Code of Australia: Plumbing Code of Australia:
Part B1 Cold Water Services Part B2 Heated Water Services
AS / NZS 3500.1-2003 Water Services; AS / NZS 3500.4-2003 Heated Water Services;
Section 1.6(a) Facilities for people with Disabilities Section 1.9 Water Temperature
Section 3.3.2 Pressure at outlets (min 50kPa) 1.9.1 Storage Temperature
Section 3.3.4 Maximum pressure within buildings 1.9.2 Sanitary fixtures delivery temperature
(500kPa static)
1.9.3 Acceptable solutions for control of delivery
Section 3.4 Velocity Requirement (Max 3.0m/s) temperatures
Section 16 Testing and Commissioning; Flushing, Section 10 Heated Water Services for People
Hydrostatic testing, cleaning and disinfection of water with Disabilities
services.
Section 11 Testing and Commissioning

1.2 INSTALLATION
Tools Required: Adjustable shifter, thread seal tape or equivalent, 5mm Allen key, Spanner, Drill

1.The pillar tap requires a minimum 13/16 or 21mm OD hole


for the BSP male tail. Insert the correct sealing washer
in to the recess of the pillar tap base.

2.Locate the pillar tap into the basin hole.

3.From underneath locate the soft sealing washer, the


washer and the backnut onto the thread and screw up.
Tighten with a spanner or shifter.

4.Connect the water supply to the inlet of the pillar tap.

5.Turn water on and activate tap. Check for leaks.

2 Free Call 1800 671 864 Visit www.enware.com.au


TFC745
2. PRODUCT COMPONENTS AND SPARE PARTS LIST

2.1 EXPLODED VIEW

TFC745 Time Flow Push Button

Spacer - Junee Adaptor

Reg M & K E L/M White

Adaptor Junee

PICTURE 2.1

2.2 SPARE PARTS New Style Spring Action After 1997

TFC790 Cartridge for Button Action Pillar Tap


TFC791 Cartridge for Lever Tap
TFC797 Service Kit
TFC35956 Lever handle for Pillar tap

Free Call 1800 671 864 Visit www.enware.com.au 3


TFC745
3. SERVICE AND MAINTENANCE

3.1 SERVICE INSTRUCTIONS


Refer to the following trouble shooting chart for specific problems and solutions. Service instructions are
supplied with spare part kits

3.2 TROUBLE SHOOTING

PROBLEM CAUSE RECTIFICATION

Leaking from Basin Tap Outlet Debris fouling knee operated time Dismantle and clean. Refer to
flow cartridge maintenance instructions. Strainer
may need to be fitted

Scale build up on cartridge jacket Dismantle and clean. Refer to


maintenance instructions.

Worn piston seals in cartridge Replace complete cartridge


assembly. Refer to TFC790/791
instructions.
Dismantle and service cartridge
assembly. Refer to TFC797
instructions

Water hammer occurs when knee Excessive water pressure Reduce water pressure by fitting a
operated valve shuts down pressure reduction valve. Maximum
pressure 500 kPa

4 Free Call 1800 671 864 Visit www.enware.com.au


TFC745
3. SERVICE AND MAINTENANCE

The time flow bib tap uses a cartridge assembly that can be
replaced with minimum effort. We suggest that a small stock
of complete cartridges be kept for immediate replacement. The
used cartridge may subsequently be reconditioned with the aid
of the service kit. Never grease the internal components of the
cartridge.

3.3 REMOVAL OF CARTRIDGE


1. Shutoff water supply.

2. Using a spanner or shifter located on the flats of the cartridge,


unscrew the cartridge and remove from the tap body ensuring
that the plastic jacket is also removed.

3. Remove any scale from the vertical groove of the jacket by


scraping with a knife. Clean the interior of the valve body and the
cartridge. Never grease the lip seal on the piston that slides in
the plastic jacket and ensure that the vertical groove in the jacket
is kept clean.

4. Refit the plastic jacket to the cartridge assembly and re-install


into the tap body. Tighten using a spanner.

5. Turn water on and check for leaks and correct operation.

6. If necessary renew the cartridge with the washers from the


service kit or install a new cartridge.

For specific problems such as a leaking tap refer to the trouble


shooting guide for instructions. Complete service instructions
are supplied with each spare part kit and these should always
be referred to before disassembling any fitting. Spare part kits
should be on hand before any complete service of the tap is
undertaken.

Free Call 1800 671 864 Visit www.enware.com.au 5


TFC745
4. CARE AND MAINTENANCE

Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning
agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Epoxy
coated surfaces should only be cleaned with a cloth and clear water or mild detergent. Use of unsuitable cleaning agents may
damage the surface. Any damage caused in this way will not be covered by warranty.
If re greasing spindles always use a silicon based potable water approved lubricant such as Hydroseal Food Pro.

5. WARRANTY

Subject to the warranty conditions and exclusions set out below ENWARE products are warranted to be free from defects in material and/or
workmanship for a period of 12 months service life and if found by ENWARE to be so defective will be replaced as set out below. If the product is sold
by a party other than ENWARE then it is sold by that seller as principal and the seller has no authority from ENWARE to give any additional warranty
on behalf of ENWARE.
The benefits of this warranty are in addition to all other rights and remedies which the purchaser may have under the Trade Practices Act (Cwth) or
similar laws of each State and Territory in Australia.

Conditions c. The failure of the product is due in part or in whole to faulty manufacture/
installation of the water supply and or electrical supply system of which
1. The product must have been installed by a licensed plumbing the product forms part.
contractor (plumbing products), or licensed electrical contractor (electrical
appliances) in accordance with the Enware installation instructions and d. The product has failed directly or indirectly as a result of excessive
application guidelines supplied with the product, and in accordance with water pressure or temperature outside the Installation Instructions &
the National Plumbing and Drainage Code AS3500 (plumbing products) Application Guideline, electrical surges, thermal input or corrosive
and SAA Wiring Rules AS300 (electrical appliances only) current at the environment.
date of installation and all relevant statutory and local requirements in the
State or Territory in which the product is installed. e. The product has failed due to foreign matter either from installation or
from the water supply.
2. Where the product is installed outside the boundaries of a metropolitan
area as defined by ENWARE, the cost of transport insurance and f. The failure of the product is due to scale formation in the waterways of
travelling shall be the purchasers responsibility the product.

3. Where the product comprises part of a water supply system or is used g. The failure of the product is due in part, or in whole, to installation not
as a dangerous goods storage system, installation of that system must in conformance with the requirements of the National Plumbing Code
be in accordance with the Code and all relevant statutory and local State AS3500, SAA Wiring Rules AS3000, or any relevant statutory and local
or Territory requirements. requirements in the State or Territory in which he product is installed

4. The product must be returned to ENWARE together with a fully and 7. ENWARE reserves the right to change its specifications without prior
correctly completed ENWARE Warranty Claim Form notice and will not accept liability for any claim arising from such change
Subject to any statutory provisions to the contrary, claims for damage
5. Where the product is replaced under warranty the replacement product to furniture, carpets, walls, foundations or any other consequential loss
carries a new warranty as detailed herein. either directly or indirectly due to malfunction of the product are also
excluded from warranty cover.
Exclusions
8. Subject to any statutory provisions to the contrary, claims for damage
6. Replacement work will be carried out as set out in the ENWARE to furniture, carpets, walls, foundations or any other consequential loss
Warranty above, but the following exclusions may cause the warranty either directly or indirectly due to malfunction of the product are also
to become void, and may incur a service charge including cost of parts excluded from warranty cover.
where:
9. The performance of water efficient products supplied by Enware cannot
a. Damage has been caused by normal wear & tear, accident, Acts of be guaranteed where the pressure compensating flow control technology
God, misuse, incorrect installation, incorrect installation of the water has been modified, removed or replaced with an alternate device and may
supply and or electrical supply system of which the product forms a part render the product non compliant to the original performance specification
or attempts to disassemble the product. & void the manufacturers warranty & performance guarantee.
b. It is found that there is nothing wrong with the product.

Free Call 1800 671 864


Visit www.enware.com.au

Enware Australia Pty Limited - 9 Endeavour Rd Caringbah NSW 2229 Australia Ph: +61 2 9525 9511 Fax: +61 2 9525 9536