Está en la página 1de 3

Formulas a utilizar

= = =
Y


= = + =

b=7.5


= =

W: 15kg; : /

Flujo Subcritico

Y1Yc

V1Vc

F1

Flujo supercritico

Y2Yc

V2Vc

F1

Tabla de dato

a) Calculo del Caudal

PARAMETRO 1 2 3 4 5 PROMEDIO
TIEMPO(S) 10.56 10.78 11.38 11.20 11.58 11.1
3
Q(m /s) 0.00142 0.00391 0.00131 0.00134 0.00129 0.00135
b) Calculo de tirantes

PARAMERO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
N 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Y 5.7 5.4 5.1 4.8 4.5 4.3 3.8 3.3 3.1 3 2.9 2.7 2.6 2.6 2.5


= == = .
( )(.)

.
= = = = .

b=7.5cm
= = . . = .

= = . /

.

.
= = = .
.

.
= + = . + = .
(. )

.
= = = .
. .

.
= = .
.

(. )
= = .
(. )

TABLA DE RESULTADOS
# N S Y(cm) A(cm2) V(cm/seg) E(cm) F Tipo de flujo
1 0 0.00321733 5.7 42.75 3.15789E-05 5.70 4.22305E-06 sub-critico
2 2 0.003048 5.4 40.5 3.33333E-05 5.40 4.57981E-06 sub-critico
3 4 0.00287867 5.1 38.25 3.52941E-05 5.10 4.9898E-06 sub-critico
4 6 0.00270933 4.8 36 0.0000375 4.80 5.46482E-06 sub-critico
5 8 0.00254 4.5 33.75 0.00004 4.50 6.02032E-06 sub-critico
6 10 0.00242711 4.3 32.25 4.18605E-05 4.30 6.44518E-06 sub-critico
7 12 0.00214489 3.8 28.5 4.73684E-05 3.80 7.75823E-06 sub-critico
8 14 0.00186267 3.3 24.75 5.45455E-05 3.30 9.58665E-06 sub-critico
9 16 0.00174978 3.1 23.25 5.80645E-05 3.10 1.05292E-05 sub-critico
10 18 0.00169333 3 22.5 0.00006 3.00 1.106E-05 sub-critico
11 20 0.00163689 2.9 21.75 6.2069E-05 2.90 1.1637E-05 sub-critico
12 22 0.001524 2.7 20.25 6.66667E-05 2.70 1.29537E-05 sub-critico
13 24 0.00146756 2.6 19.5 6.92308E-05 2.60 1.37081E-05 sub-critico
14 26 0.00146756 2.6 19.5 6.92308E-05 2.60 1.37081E-05 sub-critico
15 28 0.00141111 2.5 18.75 0.000072 2.50 1.45388E-05 sub-critico