Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PRODUCT CATALOGUE
BubbleCPAP
Contents
Section
Delivery Systems 1
Diagrams 1.1
Infant Delivery System (BC151) 1.2
Infant Delivery System (BC161) 1.2
Infant Delivery System (BC171) 1.2
Patient Interface 2
Nasal Tubing Midline 2.1
Nasal Tubing Universal 2.1
Nasal Prongs 2.1
Infant Bonnet Midline 2.1
Headgear Midline 2.1
Chinstrap 2.1
Bubble CPAP System Starter Kits 3
Starter Kit Midline Delivery System 3.1
Starter Kit I/F (Flow Driver compatible) Delivery System 3.1
Nasal Prong Starter Kit 3.2
Infant Bonnet Starter Kit 3.2
Starter Kit Midline F&P 50mm 3.2
Starter Kit Midline F&P 70mm 3.2
Starter Kit Midline F&P 100mm 3.2
Starter Kit Midline Universal 50mm 3.3
Starter Kit Midline Universal 70mm 3.3
Starter Kit Midline Universal 100mm 3.3
Accessories / Devices 4
Single-Use
Gas Supply Line 2.1m 4.1
Gas Supply Line to 2 flow meters 4.1
Midline Pressure Luer Adaptor 4.1
Mounting Options
Humidifier Stand Telescopic 4.2
Mounting Bracket C-Clamp 4.2
Mounting Bracket Pole 15-50mm 4.2
Humidification
Humidifier 4.3
Heater Wire Adaptor MR850 4.3
Heater Wire/Temp Probe Kit 4.3
Probe Temp/Flow Ang 1600mm 4.3
Gas Supply
Bird MBlender 2-16LPM DISS 4.3
Bird MBlender 2-16LPM NIST 4.3
Bird MBlender Pole Mount Bracket 4.3
Sample Setups 5
Pole Mount Setup 5.1
Infant Warmer Setup 5.2
BubbleCPAP
Delivery Systems 1.1
BC161
BC151
10
9
8
7
6
BC171
10
9
8
7
6
BubbleCPAP
Delivery Systems 1.2
Pressure Manifold
Simplified Pressure
Manifold
(BC171-10 only)
10
9
8
7
6
5
Length in mm
Infant Bonnet
Chinstrap
BubbleCPAP
Bubble CPAP System Starter Kits 3.1
10
9
8
7
6
Infant Flow compatible circuit 5
CPAP Generator
Single-Use
Telescopic
Humidifier Stand C-Clamp Pole Clamp
BubbleCPAP
Devices 4.3
Humidification
MR850 Humidifier
Gas Supply
Low Flow
Air/O2 Blender
BC501-01 Bird MBlender 2-16LPM DISS
Blender
Gas Blenders are available on an individual basis.
DISS & NIST
fittings available They come complete with color coded nipples and control knobs.
Flowrate 2-16 L/min (Bird)
0-15 L/min (Bio-Med)
Includes flowmeter nipples (green or white)
Bird MBlender Pole
BIO-MED DEVICES
Mount Bracket Note: Requires 900IW320 Bird Bracket Blender Complete to be fitted to the
CosyCot Infant Warmer. Gas hoses not included. Please refer to Fisher &
O2%
Paykel Healthcare Infant Warming Catalogue.
BubbleCPAP
Sample Setup (pole) 5.1
Bird MBlender
2-16LPM
BC502-01 (NIST)
Note:
Gas Hoses not included.
Please refer to Fisher & Paykel
Infant Warming Catalogue BC510-01
Bird MBlender
Pole Mount Bracket
MR850
Humidifier 900MR030
Mounting Bracket Pole
15-50mm
(for mounting humidifier)
900MR801
Heater Wire Adaptor
MR850
900MR868
Probe Temp/Flow
Ang 1600mm
900MR170
Mounting Bracket C-Clamp
(for mounting CPAP generator)
900MR292
Humidifier Stand Telescopic
BubbleCPAP
Sample Setup (warmer) 5.2
Low Flow
Air/O2 Blender
900MR030
Mounting Bracket Pole
MR850 15-50mm
Humidifier (for mounting humidifier)
900MR801
Heater Wire Adaptor
MR850
900MR868
Probe Temp/Flow
Ang 1600mm
900IW302
Mounting Pole long
900MR170
Mounting Bracket C-Clamp
(for mounting CPAP generator)
en
REF 185043599 Rev F 2009-07
MANUFACTURER Fisher & Paykel Healthcare Limited, 15 Maurice Paykel Place, East Tamaki, Auckland 2013; P O Box 14 348, Panmure, Auckland 1741, New
Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: info@fphcare.com Web Site: www.fphcare.com AUSTRALIA Tel:+61 3 9879 5022 Fax:+61 3 9879 5232
AUSTRIA Tel: 0800 29 31 23 Fax: 0800 29 31 22 BENELUX Tel:+31 40 216 3555 Fax:+31 40 216 3554 CHINA Tel:+86 20 3205 3486 Fax:+86 20 3205 2132
FRANCE Tel:+33 1 6446 5201 Fax:+33 1 6446 5221 GERMANY Tel:+49 7182 93777 0 Fax:+49 7182 93777 99 INDIA Tel:+91 80 4123 6041 Fax:+91 80 4123 6044
IRISH REPUBLIC Tel: 1800 409 011 ITALY Tel:+39 06 7839 2939 Fax:+39 06 7814 7709 JAPAN Tel:+81 3 3661 7205 Fax:+81 3 3661 7206 NORTHERN IRELAND
Tel: 0800 132 189 SPAIN Tel:+34 902 013 346 Fax:+34 902 013 379 SWEDEN Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 SWITZERLAND Tel: 0800 83 47 63 Fax:
0800 83 47 54 UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, United
Kingdom Tel:+44 1628 626 136 Fax:+44 1628 626 146 USA Tel: +1 800 446 3908 or +1 949 453 4000 Fax:+1 949 453 4001
Bubble CPAP System Set-up Guide
For full User Instructions, please refer to Bubble CPAP System User Instructions
(BC151/BC161 PN 185042847 and BC171 PN 185042848).
BC151 / BC161
10
9
8
7
6
5
Regularly observe that the water is feeding into the humidification chamber.
Should the water level exceed the maximum level marked on the humidification chamber,
the chamber should be replaced.
Check that all connections are tight before use and after any adjustment.
Ensure air flow is present at all times. If air flow is interrupted, turn off the humidifier.
Regularly observe the circuit for condensate. Drain as required.
Regularly observe the CPAP generator for bubbling. If bubbling is not observed, check
for and minimize air leaks in the system and at the patient. If air leaks have been
minimized, air flow may be increased to achieve continuous bubbling.
Regularly observe the water level in the CPAP generator and overflow container.
Refill the CPAP generator if the water level drops below the minimum water level line.
Check and empty the overflow container once every 8 hours or as needed.
Monitor patient oxygen levels.
Always use pressure monitoring to verify that the patient is receiving the
prescribed CPAP level.
Ensure that the fill-funnel remains on the Bubble
CPAP generator.
Ensure that the humidifier and Bubble CPAP generator
are mounted below the patient.
Water Water
level level
too low correct
5. Leak Test
Check all connections are tight before use.
Set the CPAP probe to 10 cmH2O and the input flow
rate to 1 L/min.
1 L/min Observe the CPAP generator. Gentle, audible
10
bubbling is acceptable; no bubbling means
9
8
unacceptable leakage.
7 If no bubbling is observed, check the entire system.
6
5 Remove the correct port cap from the pressure
manifold before connecting any monitoring device.
Flow
(L/min)
3 4 5 6 7 8 9 10
MR730:
40 C, -3
BC161
BC151
10
9
8
7
6
5
Regularly observe that the water is feeding into the humidification chamber.
Should the water level exceed the maximum level marked on the humidification chamber,
the chamber should be replaced.
Check all connections are tight before use and after any adjustment.
Ensure air flow is present at all times. If air flow is interrupted, turn off the humidifier.
Regularly observe the circuit for condensate. Drain as required.
Regularly observe the CPAP generator for bubbling. If bubbling is not observed, check
for and minimize air leaks in the system and at the patient. If air leaks have been
minimized, air flow may be increased to achieve continuous bubbling.
Regularly observe the water level in the CPAP generator and overflow container.
Refill the CPAP generator if the water level drops below the minimum water level line.
Check and empty the overflow container once every 8 hours or as needed.
Monitor patient oxygen levels.
Always use pressure monitoring to verify that the patient is receiving the
prescribed CPAP level.
Ensure that the fill-funnel remains on the
BubbleCPAP generator.
Ensure that the humidifier and Bubble CPAP generator
are mounted below the patient.
Water Water
level level
too low correct
5. Leak Test
Check all connections are tight before use.
Set the CPAP probe to 10 cmH2O and the input flow
10
rate to 1 L/min.
9 Observe the CPAP generator. Gentle, audible bubbling
1 L/min 8
is acceptable; no bubbling means unacceptable
7
6 leakage.
5 If no bubbling is observed, check the entire system.
6-8 L/min
(<15 L/min)
Set CPAP Level
10
9 The number on the CPAP probe above the lid
8
7
indicates the CPAP pressure in cmH2O. As an example,
6
the illustration shows CPAP setting of 6cmH2O.
Set the CPAP probe at the prescribed level
(3 to 10 cmH2O).
Flow
(L/min)
3 4 5 6 7 8 9 10
MR850: 37 C
MR730: 40 C, -3
BC171
UK EC REP
www.fphcare.com
Bubble CPAP System
The F&P Bubble CPAP System is the first complete system available in an All-in-One Pack. It includes the Bubble CPAP generator,
heated breathing circuits, humidification chamber and pressure manifold. F&P FlexiTrunk is a lightweight nasal tubing with a unique, flexible
extension for a stable prong and mask fixation while allowing for normal infant movement.
F&P Bubble CPAP System models include:
BC151 connects to other infant CPAP interfaces (e.g. Hudson and Inca prongs)
BC161 connects to the F&P Infant Interface
BC171 connects to the M672P Infant Flow Driver (IFD) or equivalent
BC161 BC171
BC151
10 10
9
9
8
8
7
7
6
6
5
5
10
9
8
7
6
5
Easy to Use
Easy auto-leveling by simply adding water into the Fill Funnel on the Bubble
CPAP generator
Excess condensate automatically drains into the detachable overflow
container (see image on right)
Detachable overflow container can be emptied without interrupting CPAP
Optimum Humidification
The F&P Bubble CPAP System provides respiratory support with
body-temperature pressure-saturated gases to the infant
Optimal humidity promotes mucociliary clearance and reduces the work of
breathing
BC151*
BC161*
185034230 EN Rev B 2012 Fisher & Paykel Healthcare Limited
BC171*
* Box of 10
Note: For ordering information, please refer to the Fisher&Paykel Healthcare Bubble CPAP Product Catalogue (Part No. 185043599).
MR850 Humidifier must be purchased separately.
www.fphcare.com
Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348, Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100
Fax: +64 9 574 0158 Email: info@fphcare.co.nz Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22
Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221
Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011
Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: +0800 132 189 Spain Tel: +34 902 013 346
Fax: +34 902 013 379 Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625
Turkey Tel: +90 312 354 34 12 Fax: +90 312 354 31 01 UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead,
Berkshire SL6 7BU, UK Tel: +44 1628 626 136 Fax: +44 1628 626 146 USA Tel: +1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001