Está en la página 1de 2

ARCHITECTURAL WINDOW FILMS

Solar Gard LX 80

With an unparalleled optical clarity, LX 80 features low reflectance for


uncompromised views and considerable solar energy rejection to keep
room temperature comfortable and reduce cooling costs.

Improve the quality of your life by keeping out uncomfortable heat,


protecting your furnishings and letting in the view you love, while keeping
visual reflectivity minimal.

Film performance (Comparison testing 1/8 (3mm) thick clear glass)

without film with lx 80 window film

Visible light 90%


transmittance @ 550nm 80%
Visible light reflectance 9%
(exterior) 9%

Visible light reflectance 9%


(interior) 10%

Ultraviolet light 27%


blocked >99%

Total solar 14%


energy rejected 40%

0 20 40 60 80 100
p e r f o r m a n c e p e r c e n ta g e

www.solargard.com
ARCHITECTURAL WINDOW FILMS

Solar Gard LX 80

Performance Parameters for Different 1/8" (3mm) 1/4" (6 mm) 1/8 (3mm) 1/4 (6mm)
Single clear Single clear Double clear Double clear
Window Types
No film LX 80 No film LX 80 No film LX 80 No film LX 80

Visible light
Transmittance % 90 80 89 79 81 73 79 71
Reflectance exterior % 90 81 89 80
Reflectance interior % 9 10 9 10 16 15 15 15
Glare reduction % 11 11 11 11

Solar energy
Transmittance % 83 54 77 50 69 46 61 41
Absorptance % 9 21 16 31 18 30 27 41
Reflectance % 8 25 7 19 13 24 12 18
Total solar energy rejected % 14 40 18 41 24 41 30 42
Infrared rejection @ 780 to 2500 nm % 1 20 79 28 82
Shading coefficient .98 .69 .94 .68 .87 .68 .81 .66
Solar heat gain coefficient .86 .60 .82 .59 .76 .59 .70 .58
Light to solar heat gain ratio (VLT/SHGC) 1.05 1.33 1.08 1.34 1.08 1.23 1.13 1.22
Solar heat gain reduction % 30 28 22 18
Performance results generated using LBNL Window
Thermal energy 7.2 and NFRC standards. For full details and additional
Emissivity .84 .78 .84 .78 .84 .78 .84 .78 information please visit www.solargard.com.

Winter U-factor (Btu hr/ft F) 1.04 1.01 1.02 .99 .48 .47 .47 .46
SK0314LX80 04/16
Summer U-factor (Btu hr/ft F) .94 .90 .92 .89 .50 .49 .50 .49 Copyright 2016, Saint-Gobain Performance Plastics
Winter heat loss reduction % 3 3 2 2 and/or its affiliates

Ultraviolet light All Rights Reserved

Blocked @ 300 to 380 nm % 27 >99 34 >99 41 >99 50 >99

Fade control
Tdw-ISO @ 300 to 700 nm % 2 85 54 82 54 74 49 70 48 www.solargard.com
1 Infrared rejection = 1 - average unweighted transmittance using ASTM E 903.
2 Tdw-ISO is the percentage of transmitted light that causes fading. A lower number means more protection against fading.