Example (11.4):
Design an appropriate footing/footings to support two columns A and B spaced at distance 2.1 m
center-to-center, as shown in Figure 11.13.a is 20 cm 30 cm and carries a dead load of 20 tons
and a live load of 10 tons. Column B is 20 cm 40 cm in cross section but carries a dead load of
30 tons and a live load of 15 tons. Width of footing is not to exceed 1.0 m, and there is no
property line restriction.
27
28
Solution:
1- Select a trial footing depth:
Assume that the footing is 50 cm thick.
2- Establish the required base area of the footing:
q all (net ) = 20 1.5 (1.7 ) 0.5 (2.5) = 16.2 t / m 2
20 + 10 + 30 + 15
Areq = = 4.63 m 2
16.2
To locate the resultant of the column forces, replace the column load system with a resultant force
system, or
28
29
l1 + x1 = l 2 + x2 , or
l 2 l1 = x1 x2 = 0.42 m (a)
4.63
Let B = 1 m, length of footing L = = 4.63 m , taken as 4.65 m
1.0
l1 + l 2 + 2.1 = 4.65 m and
l1 + l 2 = 2.55 m (b)
P +P 40 + 60
qu (net ) = Au Bu = = 21.51 t / m2
LB 4.65 (1.0 )
4- Check footing thickness for punching shear:
Column B:
Effective depth d = 50 7.5 0.80 = 41.7 cm (lower layer)
The factored shear force
Vu = 60 (21.51)(0.817 )(0.617 ) = 49.16 tons
2
Vc = 0.53 f ' c 1 + bo d
Vc = f ' c bo d
29
30
Column A:
The factored shear force
Vu = 40 (21.51)(0.717 )(0.617 )= 30.48 tons
2
= 0.53 (0.75 ) 300 1 + (266.8 )(41.7 ) / 1000 = 178.73 tons
30 / 20
Vc = f ' c bo d
30
31
(b)
(c)
(d)
(e)
Figure 11.13: (continued); (b) Footing dimensions; (c) factored soil
pressure; (d) shearing force diagram; (e) bending moment diagram
6- Check footing thickness for beam shear:
Vc = 0.75 (0.53 ) 300 (100 )(41.7 ) / 1000 = 28.71 tons
Maximum factored shear force Vu is located at distance d from the exterior face of column B,
b. Transverse reinforcement:
Effective depth d = 50 7.5 1.6 - 0.80 = 40.1 cm (upper layer)
31
32
M uA =
40 (0.701) 1 0.2 = 3.2 t .m
2
(0.701)(1.0 ) 2 2
0.85 (300) 2.353 (10 )5 (3.2 )
= 1 1 = 0.00076
4200
0.9 (70.1)(40.1) 2 (300)
Under Column B:
M uB =
60 (0.801) 1 0.2 = 4.80 t .m 2
(0.801)(1.0 ) 2 2
0.85 (300) 2.353(10 )5 (4.8 )
= 1 1 = 0.0010
4200
0.9 (80.1)(40.1)2 (300)
PBn = 0.65 (0.85 )(300 )(20 )(40 ) / 1000 = 132.6 tons > 60 tons
t = e = = 1 and s = 0.8
32
33
100 15 1.6
7.5 + 0.8 = 8.3 cm , or = 5.21 cm , i.e., cb = 5.21 cm
8 (2 )
cb + Ktr 5.21 + 0
= = 3.26 > 2.5 , take it equal to 2.5
db 1.6
33
34
Example (11.5):
Design a combined footing, to support two columns A and B spaced at distance 6.0 m center-to-
center as shown in Figure 11.14.a. Column A is 40 cm 40 cm and carries a dead load of 50 tons
and a live load of 30 tons. Column B is also 40 cm 40 cm in cross section but carries a dead
load of 70 tons and a live load of 50 tons.
Use f c = 250 kg / cm 2 , f y = 4200 kg / cm 2 , and q all (net ) = 1 .50 kg / cm 2 .
Solution:
1- Select a trial footing depth:
Let footing thickness h = 80 cm
2- Establish the required base area of the footing:
PA + PB
Areq =
q all (net )
50 + 30 + 70 + 50
Areq = =13.33 m2
15.0
To locate the resultant of the column forces,
PB (6) = R ( x ) , or 120 (6 ) = (80 + 120)( x ) and x = 3.60 m
34
35
P +P 108 + 164
qu (net ) = Au Bu = = 19.88 t / m2
LB 7.60 (1.80 )
2
= 0.53 (0.75 ) 250 1 + (263.2 )(71.6 ) / 1000 = 355.33 tons
40 / 40
Vc = f ' c bo d
Column B:
35
36
2
Vc = 0.53 f ' c 1 + bo d
2
= 0.53 (0.75 ) 250 1 + (446.4 )(71.6 ) / 1000 = 602.65 tons
40 / 40
Vc = f ' c bo d
(c)
(d)
(e)
Figure 11.14: (continued); (c) Factored soil pressure; (d) shearing force
diagram (not to scale); (e) bending moment diagram (not to scale)
6- Check footing thickness for beam shear:
Effective depth d = 80 7.5 0.90 = 71.60 cm (lower layer)
36
37
Maximum factored shear force Vu is located at distance d from the left face of column B,
c- Short direction:
Under Column A:
Effective depth d = 80 7.5 1.6 0.8 = 70.10 cm (upper layer)
M Au =
108 (0.7505 ) 1.8 0.4 = 14.70 t .m
2
(0.7505 )(1.80 ) 2 2
0.85 (250 ) 2.353 (10 )5 (14.70 )
= 1 1 = 0.0011
4200
(75.05 ) (0 .9 ) (70.1) 2
(250 )
Under Column B:
M Bu =
164 (1.101) 1.8 0.4 = 22.32 t .m
2
(1.101)(1.80 ) 2 2
37
38
t = 1.3 since more than 30 cm of fresh concrete is cast below the reinforcement, e = = 1 and
s = 0.8
7.5 +1= 8.5 cm, or 180 7.5 7.5 2 = 4.29 cm , i.e., cb = 4.29 cm
19 (2)
cb + Ktr 4.29 + 0
= = 2.145
db 2.0
2.0 (0.8 )(1.3 ) (4200 )
ld = = 73.59 cm
2.145 (3.5 ) 250
7.5 + 0.8 = 8.3 cm, or 180 7.5 7.5 1.6 = 6.81 cm , i.e., cb = 6.81 cm
12 (2)
cb + Ktr 6.81 + 0
= = 4.26 > 2.5 , take it equal to 2.5
db 1.6
38
39
39