ZAPATA EXCNTRICA 6-D

VP-104 0.45

L.P s/c NPT


4.75 m

= 1.65 m

= 1.9 /3 / = 350 /2
= 17 /3 (coef. De reaccion del terreno) = 350 /3
= 6 /2 = 4200 /2

: :
= 235.88 = 1.28 = 0.13
= 58.12 = 0.63 = 0.04

A. ESFUERZO NETO DEL TERRENO:

= - / = 56.52 /2

B. DIMENSIONAMIENTO EN PLANTA DE LA CIMENTACIN:

L.P
S= (2.0 - 2.5)T
Tomando: S=2T

+
= = = 5.202 2

b S
2 = 5.202 T= 1.613 = 1.62 m
D
USAR TxS = 1.85 x 2.85 2

T
= + = ## + 58 = 294.00 tn
= + = 1 + 1 = 1.91 tn (. )
= + = 0 + 0 = 0.17 tn (. )

= = 0.001 m 0.003 m = 0.80 m
6

= = 0.006 m 6 S 0.039 m S= 0.55 m

6 6
= + 2
+ 2 = 56.52 2

6 6
= 2 0 2
2
C. PREDIMENSIONAMIENTO DE LA ALTURA "HZ" DE LA ZAPATA:
Criterio del Dr Yamashiro:
3 expresion de predimensionamiento
= 2.1 recomendado por el Dr. Yamashiro.

: Altura de la zapata
Dimension de la zapata en la direccion de la exentricidad.
Coeficiente de reaccion del terreno (BALASTO)
15000 (kg/2 )

h= 0.73 m
h= 0.70 m

Criterio de longitud de desarrollo:


= 0.08 = 3/4

= 0.34 m
= 0.44 m
= 0.45 m

USAR = 0.70 m.
D. PREDIMENSIONAMIENTO DE LA COLUMNA DEL 1ER PISO (TIPO C2):

1.25 1.25( + )
= = =
0.25 0.25
= 4200 2
0.65 x 0.65 = 4200 2 tomamos:
De las combinaciones: 0.70 x 0.70 = 4900 2 0.70 x 1.05 m2
0.70 x 1.05 = 7350 2

Elegir el que tiene mayor peralte en el sentido de excentricidad.


E. CONDICION DE DIMENSIONAMIENTO: P

Del caso 1: (e<T/6)

6 6
1 = + 2 2 = 2

e

12 =
1 2 =
2
=
1
1 2 = 12( ) 1 2 = 12

T/2 T/2

Dr. Yamashiro: = 1 2 = 12
1 2

= . .


= 3
0 12 3
(, ) = =
12
=

: . 1 2 1 2 ,
, ( 3 2)
b. .
( 6)
En el problema:

1ER. TANTEO: Columna bxD = 0.70 x 1.05 m2 Hz= 0.70 m

= 2.08 1
= 2
= 0.102
= 0.14 1 3
1 + 2[2 + 6( + 6)]
+2 0.069
= -9.9827 2
= 9.98273 CONFORME

: Col= 0.70 x 1.05 m2


Hz= 0.70 m
d= 0.61 m
E. TRANSFERENCIA DE ESFUERZOS EN LA INTERFASE COLUMNA CIMENTACION:
Resistencia al aplastamiento sobre la columna:

= = 654.909 tn
CONFORME
= 0.85 = 2186.63 tn

Resistencia al aplastamiento en el concreto a la cimentacion:




= = 654.909 tn 0 = 0.5

2 = 0.4
2
= 0.85 0 0 = 2
1
0 = 0.8
2 = 0.5
2
= 0.7619 0 = 5.6
1
= 0.85 0 = 1666 tn CONFORME
F. DISEO POR FLEXION:
F.1. En la direccion de la excentricidad:

= = 247.8 tn/m

Pu= 2
= = 79.3 tn.m
2
1.70
= 0.85 0.7225
2
1.05 lv= 0.80 m
= 0.024
= 0.0020342
= 35.13 2 = 35.13 2
= 31.08 2 = 5/8
= 17.75
= 247.8 tn/m = 18.00
1.85 m s= 0.16

: 18 5/8 @ 0.16 m

F.1. En la direccion transversal:



= = 160.9 tn/m

Pu= 2
= = 92.94 tn.m
2
1.70
= 0.85 0.7225
2
lv= 1.08 0.70 1.08 m
= 0.085
= 0.0070484
= 79.01 2 = 79.01 2
= 20.18 2 = 1
= 15.59
= 160.9 tn/m = 16.00
2.85 m s= 0.12

: 16 1 @ 0.12 m

G. CONDICION ADICIONAL DE DISEO:


G.1 Caso de la viga: "se le debe aadir el refuerzo adicional"

= = = 38.61 tn
0.90

= 10.213 cm2
= 1/2
= 8.06
= 9.00

G.2 Caso de la columna: "se debe verificar la condicion adicional"

= 458.4 tn = Se debe comparar


= 156.4 tn-m = 2 esta cuantia con el


= = 0.341 m = 3/4 determinado por
= 0.00 analisis de portico
= 0.00 correspondiente.