CALCULO DE LA POTENCIA EN LA BOMBA

1.1 Volumen de la cisterna:


3
= 1200 = 900
4

1.2 Volumen del tanque elevado


1
= 1200 = 400
3

Vtc > 1000 entonces Vtc= 100 Ltr.


1.3 Caudal de bombeo

Mps = 65 U.H
Mps = 1.235 Ltr/seg
Qb = Mps = 1.235 Ltr/seg
1000
Qll = = 0.18 Ltr/seg Se escoge el mayor
1

Entonces Qb = 1.235 Ltr/seg

1.4 Altura dinmica total

Hpt = Hg + Hf(succin + imp) + Pmin


Hg = 1.6 + 6.85 + 1.6 + 1.5
Hg = 11.55 m

1.4.1 Hf succin
1"
D impulsin = 1 segun tabla anexo N5 de R.V.E
4
1"
D succim = 1
2
Longitud real = 1.60 m
Accesorios = 1v pie + 1 codo
L equivalente = 10.519 + 2.159 = 12.678
L total = L real + L equivalente = 14.278
Hf succin = 1.005 m
1.4.2 Hf impulsin

1"
D impulsin = 1
4
L real = 9.95 m
Accesorios = 1 v.ch + 1 v. comp + 3 codos
L equivalente = 2.705 + 0.278 + 3x1.818 = 8.437
L total = 9.95 + 8.437
L total = 18. 387 m
1.2351.85 0.048387
Hf succin = 1.72106
1001.85 1.254.84
Hf = 3.12m

1.4.3 HDT

HDT = 11.55 + (1.005 + 2.53) + 2.00 = 17.675


1.4.4 Potencia de la bomba
Entonces:
1.235+17.675
PB =
75 0.60
PH = 0.485 HP NO ES COMERCIAL
PH = 0.50 HP