GE Energy

Synchronous
Hydro Generators
Horizontal & Vertical Applications
Power: 2,000 37,500 kVA
Speed: 150 900 RPM
Voltage: 3,000 13,800 Volts
Frequency: 50 & 60 Hz
Experience Matters
Weve manufactured generators for
over 100 years.
GE has the capability to design and manufacture electrical
machines for the most stringent application requirements. This
century of achievement has built a rich tradition of technical
excellence, quality and reliability.

Industry
Power Generation Hydro Energy

Application
This line of synchronous generators has been specifically designed
in response to the growing demand of small hydro plants. It
incorporates a full range of features to address the applications
and operational conditions demanded by this industry. This
product line is customized for horizontal & vertical hydro turbine
applications in a range of 2,000 37,500 kVA, 150 - 900 RPM.

GE Advantages
Rugged & compact design. Easy installation. Reliable operation.

Shipped assembled or disassembled, based on customer request

Compact construction with a small foundation


The rigid mechanical configuration (shorter distance between
bearings) allows for low vibration levels

Follows critical industry trends for simple, modular and


integrated designs

Proven GE insulation system makes for a durable and


reliable machine

Modularized construction for fast and easy site installation

Rotor designed to meet higher runaway speeds specific to hydro


applications for Francis and Kaplan turbines

2
Construction
Frame Laminated Spider
The stator frame is made of welded The rotor spider is made of thin
steel construction and manufactured laminations, clamped with axial
with thick steel plates to prevent studs. According to design needs,
distortion during operation. Robust there are axial holes to improve the
and rugged, these frames are air ventilation through the rotor. The
designed to withstand the mass of
laminated poles are attached to the
a stator core, bending stresses and
spider with dovetails.
deflections. The frames are designed
to minimize vibrations and noise
levels. The frame bore is machined to Solid Spider
ensure a uniform air gap between the Stator Core The rotor spider and shaft are
rotor and stator, thereby minimizing The stator core assembly consists of
obtained from a one-piece machined
the unbalanced magnetic pull. These segmented and insulated laminations
carbon steel forging. According to
frames are designed to withstand the of cold-rolled low-loss silicon steel,
extreme stresses due to short circuits. design needs, there are axial holes to
clamped between substantial side
improve the air ventilation through
plates. Laminations are stacked up
Each machine is designed to be the rotor. The laminated poles are
with a controlled burr in order to
assembled on a robust concrete fixed on the spider by using dovetails
ensure minimal losses. Lamination
foundation or steel base. A minimum on the pole bottom.
steel is selected based on project
of four lifting points is provided in the
requirements. The core is built inside a
generator to facilitate this process.
Larger or heavier machines, which structural cage, which is then inserted Rim Spider
are shipped disassembled, are into the frame and attached through The rim is made of forged steel.
reassembled over the foundation weldments. Steel I-beam spacers The rim is shrunk on to a large web
at the site, as a part of the field spot welded to low carbon steel that is attached to the shaft by
installation process. laminations form radial ventilation means of a hub and a key, then pole
ducts along the core length. When bodies are attached to the rim via a
The frame is fabricated from structural core building is complete, the whole number of radial bolts.
steel plates to ensure an extremely assembly is clamped under pressure
robust and rigid support structure. The with studs. The nuts and compression Two axial or radial fans (according
generator can be designed for open plates are welded in place while to design characteristics) are
enclosure and totally enclosed water- maintaining pressure. mounted on the shaft to provide
to-air cooled. The exciter and rectifier airflow to maintain the machine
hub are mounted at the non-drive
temperature within the limits
end (NDE) enabling easy access for Rotor specified. The fans are used to
maintenance purposes. Three types of rotor construction
provide double-ended ventilation,
can be utilized in this product line:
helping ensure an even temperature
a laminated spider with dovetailed
distribution across the field and
poles, a rim spider with bolted poles, or
stator windings.
a solid spider with dovetailed poles.

Laminated Poles
The rotor has laminated poles fitted
with strip or wire wound
field coils and supplied with an
amortisseur winding on the
outer pole face.

Rotor with shaft-mounted out board exciter


3
Insulation
Mica composite, epoxy resin and
vacuum-pressure impregnation
(VPI) provide a robust and reliable
insulation system.

The advanced insulation system


on all large machines will typically
reward you with years of reliable
operation. GEs insulation system is
designed to minimize the effect of
localized electrical stress and reduce
the effects of partial discharge
while increasing machine life and
reliability. Components are selected
to ensure reliability of the system as
a whole.

The insulation system can meet


applicable standards. All wound
stators undergo global vacuum-
pressure impregnation (VPI)
treatment. Curing binds the stator
components into a solid and rigid
structure with excellent dielectric Even stator coil spacing maintains the electrical and mechanical integrity of the machine.
strength, dimensional stability and
mechanical strength. It also increases
the resistance of the winding to
Ground Wall
thermal shock, moisture and other Insulation
contaminants.

Coil Insulation Turn


Once assembled, the coils are inserted Insulation
into the stator slots and the end
connections are brazed and taped.
GEs coil lock bracing system supports Strand
Insulation
the coils and makes the entire
structure more rigid.

Copper
Conductor

The binding agent used is GEs third The coil turns in the slot section are
generation epoxy resin, selected and bonded using heat and pressure to
tested to IEEE-1776 for chemical achieve dimensional accuracy of the
compatibility, thermal/dimensional finished coil.
stability, and electrical properties.

A protective armor of heavy Above 6000 volts, a semi-conducting The mica composite insulation is designed for
glass tape is used for protection paint is applied to the slot portion and uniform ground insulation dielectric strength.
against mechanical shock and graded beyond the core to provide
abrasion. corona protection.
4
Excitation
Brushless Excitation with enamel covered round copper
wire. The whole assembly then
System undergoes a varnish treatment.
The exciter is a three-phase AC
generator with a rotating three-
The rectifier hub includes liberally
phase bridge rectifier.
rated diodes. The leads from the
armature are connected directly
The exciter stator core is made to the hub, and the two DC output
of laminated, hot rolled or cold leads from the hub are connected
rolled steel, held together by steel to the main field and clamped to
endplates. prevent movement. Collector Ring with
The DC field coils are wound in a The exciter armature and rectifier hub
Brushes
concentric pattern using formers The brushes are electrographite
are assembled by interference onto
and mounted on the frame poles. type, open terminal. The quantity of
the shaft. The complete exciter and
brushes is determined taking into
rectifier hub assembly is enclosed
The whole assembly undergoes a account the current density required
in a steel sheet cover. For ease of
varnish treatment.The exciter rotor for an efficient working of the
maintenance, a removable plate
armature consists of a three-phase excitation system. The brush holders
gives access to the rectifier hub.
winding system. The core consists are selected in order to provide the
of steel laminations that are stacked required contact pressure between
As a protection for the diode bridge the brushes and the collector rings.
and held with end plates and wound under normal conditions, a varistor
is supplied in parallel with the
The collector rings are low carbon
rectifier hub.
steel material, providing thermal
conductivity required to keep the
system at the temperature level
according to applicable standards.
There are two kinds of collector
rings: smooth (standard) and
grooved rings (for special cases).

Brushless exciter complete with rectifier hub


5
Bearings
Bearings NDE thrust bearing is insulated Horizontal
from the thrust bearing housing. A
removable link is provided to ground There are normally two sleeve
Vertical
the drive end guide bearing and to bearings, each mounted on a pedestal
There is a standard arrangement for that is bolted to the base. Each
facilitate testing of the thrust bearing
the bearings configuration: thrust and bearing liner is made from steel, lined
insulation.
guide bearing at NDE side and only with white metal and is split on the
guide bearing at DE side. horizontal centerline. The standard
DE guide bearing is assembled at
two-bearing arrangement (which
the lower endshield, together with its
NDE thrust bearing is assembled into can be varied, by agreement, to suit
support, and it works in contact with a
a housing, which is bolted at the upper the type of coupling used) assumes
track built in the rotor shaft.
endshield, and the upper endshield is a limited end-float coupling, and
bolted against the stator frame. non-locating bearings are provided.
Lower endshield is bolted against the (Typical end-float is inches).
stator frame, and it is positioned at the
NDE guide bearing works in contact
with a thrust block, which is the piece inner side of the stator frame.
Thrust bearing can be provided on
that connects the rotor shaft to the the DE or NDE side, according to
thrust bearing surface, by means of a All the components assembled at the requirements.
key connection in the shaft. lower endshield (DE guide bearing,
supports and covers) are split, in order
Oil throwers on the shaft and
to permit the assembling process (due
High-pressure oil lift systems are oil seals on the pedestal are
to rotor shaft flange diameter, usually
frequently supplied at NDE thrust provided to prevent oil leakage and
larger than DE guide bearing inner
bearing to allow easy start-up (due to contamination. High-pressure oil
diameter). The access to those pieces
the high pressure at the thrust bearing lift systems are frequently supplied
is done by means of openings in the
surface) and also better installation at each bearing to allow for easy
lower endshield, which is closed after
and maintenance handlings. installation and maintenance.
the assembly process is finished.
NDE bearing liner is insulated from
the bearing housing. A removable link
is provided to ground the drive end
bearing and to facilitate testing of the
bearing insulation.

6
Cooling System
Enclosure and
Ventilation
The generator is designed for open Air is circulated inside the machine
enclosure (WPI, IP23/24) or totally by two internal fans and the rotor.
enclosed air-to-water (TEWAC/CACW) The radial ducts in the stator core,
cooling system (top or bottom cooling). the design of the end windings and a
careful review of the air path, ensure
temperature uniformity in all parts of
the machine.

Top Mounted Cooling

Bottom Mounted Cooling

Cooling circuit for vertical generators

7
Options and Accessories
Automatic Voltage PERMANENT
MAGNET BRUSHLESS SYNCHRONOUS
Regulation (AVR) GENERATOR EXCITER GENERATOR
The AVR utilizes a fast response EXCITER
EXCITER DIODE ROTOR STATOR
FIELD
microprocessor to control its AC to DC (PERM. MAGNET) ARMATURE RECTIFIER FIELD WINDINGS

converter power stage output that SYSTEM


BUS
GCB
provides excitation to the generator
to regulate the difference between EXE

the generator stator voltage reference 1000A PT


set point and feedback signal to
zero. Reactive power sharing during PMG
ARMATURE
EXCITER
FIELD CT

(3A to 15A)
parallel operation of generator with 10

IDC
other generators or a power system or
30 NGR
is achieved by the use of droop
compensation where the voltage
feedback signal is increased by PMG
POWER IN
FIELD
SETPOINT OUTPUT
typically 0% to 5% as lagging reactive INPUT
PERMANENT CT
08

load current increases from 0% to AVR


MAGNET BRUSHLESSPT SYNCHRONOUS
100%. The following four operating GENERATOR EXCITER GENERATOR
10 or 30

control modes with a bumpless EXCITER AUTOMATIC VOLTAGE REGULATOR


EXCITER
(DECS UNIT DIODE
OR EQUIVALENT) ROTOR STATOR
FIELD
transfer between modes are available (PERM. MAGNET) ARMATURE RECTIFIER FIELD WINDINGS

to suit the site requirements: GCB


SYSTEM
BUS

Sequence of events recording EXE


& oscillography, which is useful Permanent Magnet Generator PT
during commissioning diagnostics 1000A
(PMG)
AVR automatic voltage regulation PMG supplies continuous power EXCITER
FIELDto the exciter
PMG
CT HEATER
(with switchable reactive power ARMATURE
CT1 (1)
(3A to 15A)

through the voltage regulator in order to C10


50/5A,
droop compensation for basic 10
NEUTRAL
IDC

parallel operation) maintainor


30
up toCURRENT
300% short circuit current fromNGR
the alternator during a fault condition. It provides
Generator PF power factor control full exciter power, regardless
(for connection to large power PMG
13,800:120/240 V of the generator RS
voltage. FIELD
POWER IN 10A/10OUTPUT
sec
system) SETPOINT
INPUT
08
CT
Generator VAR reactive power AVR
PT
control (for connection to large 10 or 30
power system) Neutral
AUTOMATICGrounding
VOLTAGE REGULATOR
(DECS UNIT OR EQUIVALENT)
Resistor (NGR)
Brushless exciter field current The NGR acts to limit generator fault current to a low level when a phase-to-
(manual mode) regulation ground fault occurs. It also serves to protect the generator from excessively high
magnetic stresses and temperatures caused by high fault currents. The NGR is
Other functions of the AVR include: time-rated.
Voltage soft-start build up
Minimum and maximum excitation
and stator current limiters HEATER
CT1 (1)
50/5A, C10
NEUTRAL
CURRENT

13,800:120/240 V RS
10A/10 sec

8
Accessories
Partial discharge sensor kits
Bearing RTD (Resistance
Temperature Detector)
Space heater 50/60 Hz
Large oversized fabricated
steel main terminal box frame
mounted
Fabricated steel neutral terminal
box frame mounted
Surge Arrestors and/or Surge
Capacitors
Current and Potential Transformers
Vibration monitoring equipment
Water leakage detector
Couplings
Generator control and protection
panel optional
Medium voltage switchgear
optional
Terminal box with lightning arresters, surge capacitors and current transformers

Remote Monitoring and


Diagnostics
GEs comprehensive industrial Features Benefits
machine monitoring strategy is GE can provide a complete motor Wireless network reduces
designed to enhance the capabilities monitoring solution: installation (cabling) costs
of industrial customers to reduce Comprehensive motor condition
downtime and identify industrial Predictive maintenance intervals
monitoring streamline maintenance schedules
machine failure before it happens.
Elements of GEs solution include: Text message/email alerts based on actual operating
Continuous technical support 24-hour monitoring support conditions
through the GE Monitoring and Reduced maintenance costs
24-hour engineering support
Diagnostic (M&D) Center
Warehoused condition data Increased machine productivity
GE engineers with remote
Web-based access for customer Increased operating efficiency
access to motor condition data
can identify potential failures of visualization of data Minimize risk of catastrophic
industrial machines Wireless transmission of data damage to equipment
Advanced technology products Quick installation with minimal
designed to easily retrofit existing GE offers several options for the disruption to operations
customer equipment and provide remote monitoring of your industrial Minimal footprint - installs on any
the highest levels of protection asset. The parameters identified accessible DIN rail
and reliability herein are configurable based on
Installation and commissioning customer/application need. GE is
prompt comprehensive service committed to complete customer
built upon GEs years of field satisfaction and will work to ensure
engineering experience, OEM the monitoring package chosen
product knowledge, and access to will serve the customers individual
product information needs.
9
Testing
Test Capability
GE has world-class test facilities. Mechanical Run
Extensive experience in the Including vibration analyses using
performance of rotating machinery velometers; dynamic balancing
with all forms of fixed and variable
Efficiency
speed drives has been accumulated.
Segregated loss method per IEEE
115
Each machine is tested at the
factory before shipment for Insulation Resistance &
installation in the field, thus reducing Polarization Index
set-up time. Dielectric Tests
In the stator, rotor and brushless
In-Process Testing Short Circuit Test exciter
Rotor impedance, surge test; Up to 130% of rated stator current Lubrication System
AC dielectric tests, prior to VPI No Load Saturation Test Functional tests
Running Tests According to Up to 125% of rated stator volts
International Standards: Short Circuit Ration (SCR)
NEMA MG1/IEEE 115, IEC 60034-1 From test data
& 60034-2 or ABNT 5052

The Right Choice


Power Solutions Team
Experienced application engineers are available to solve
your toughest generator system challenges.

Installation, Start-up & Commissioning


Experienced engineers/technicians available to
support site erection, installation and commissioning

Long term service agreements including remote


monitoring and maintenance assistance

Parts center supports your local needs and helps


assure your up-time requirements.

For more information, please contact your GE sales representative.

GE Energy
800 541 7191

www.gemotors.com
2011 General Electric Company. All rights reserved.
GE and GE Monogram are trademarksof General Electric Company.

GEA18285

También podría gustarte