SCHEDULE OF FINISHES

Walls
Footings 230x600mm in medium strength concrete to NBR standard and SANS 10400.
Walls are built with 90mm bricks - heights as per plan. External walls to plastered and
painted with 50mm cavity between internal and external skins with 2.5 butterfly wire ties
per square meter. All internal walls plastered with lime cement.
26.5 Brickforce in 4 layers over all openings, with precast concrete lintels to openings greater
than one metre.
ROOF PITCH

1,609
Window-sills
300 300 External & Internal, smooth finished cement plaster.

Roof Construction
4,159 Cement roof tiles @ 26.5 pitch on 38x38 SAP battens at maximum 320 centres on
DPC prefabricated gangnail trusses at maximum 760 c/c, fixed to 114x38 wallplates and
anchored to brickwork with 30x2mmx1m hoop iron ties, built into walls for minimum of
PLASTER & 600mm. SABS approved underlay to tiled roof. All roof timber to be minimum Grade 5 SA
2,550

PAINT Pine TAN treated. All gable ends to be tied with hoop iron built into wall for minimum
NGL 600mm and up to two trusses away from gable to SANS 10400-L where applicable.
Bracing as per A19 Engineer.
FRONT ELEVATION 1
SCALE 1:100 Eaves
BATHRM LOUNGE 300mm Open eaves overhang with 225mmx10mm painted fibre cement fascias.
DPC DPC
400x200 250mic DPM
375mic DPM UNDER ALL WALLS Rainwater Disposal
THICKENED
MINIMUM 150mm ABOVE FGL Alu. gutters with 75mm PVC downpipes as per plan.
FOUNDATION
600x230 600x230
SECTION A-A Ceilings
SCALE 1:100 25mm Isoboard EPS ceiling on 38 x 38 SA Pine battens at 300mm spacing and 76mm
Rhino cornice with 155mm thick flexible polyester blanket(Isotherm).

Floors
Finished as per plan and/or client choice/building tender, on 25mm screed, on 80mm
concrete for ground storey, (as above) on 250 micron waterproof sheeting, on
compacted filling and sand blinding. All floor levels to be a minimum of 150mm above
3 FGL.

Doors & Windows


5,760 Windows top-hung aluminium, as per plan codes & elevations.
230 90 230 Note : Safety glass to window panes larger than 1sq.m or closer than 500mm from FFL
2,710 2,500 to SANS 10137 and to comply to SANS 10400-N.
230
1,710
90
910
90
2,500
230 ELEVATION 2
SCALE 1:100 Drainage
110mm Smooth uPVC Sewer pipe with minimum 1:60 fall with IL at minimum
450mm. 50mm 2way vent valve on start of one pipe sewer system. All sewer lines
1,130 900 3,730 passing under structure to comply to SANS 10400-PP24 (encase in sand or concrete).
W6 All drainage to comply to SANS 10400-P.
(900x1100)
230

230

230

Electricals - as per building tender.


1,110

Position of Oostersee Electrical connection box on exterior wall to be determined on


BEDRM 2 site.
(Carpet)
(900x1100)

NOTES:
2,250

BEDRM 1
3,160

Figured dimensions takes preference to scaled dimensions.


W6
2,840

900

(Carpet)
3,270

All relevant levels and dimensions to be verified on site prior to construction.


All work to comply to NBR, Local Bylaws and Municipal Regulations.

All levels to be determined on site and can/may be to adjusted to the descrepancy of


90

B.I.C the developer and his appointed builder. Developer to approve plan prior to submission
(600x900)

to council.
90

B.I.C PLASTER & PAINT


2,840

All glazing to SANS 10137 & SANS 10400-N. Printed dimensions take prference over
W3
600

BATH RM scaled dimensions. All work to be carried out in strict accordence to NBR and local
90

ELEVATION 3
7,830

7,830

2 A (Tiles) TV A 4 bylaws.
2,030

50
SCALE 1:100
HWC IN
ROOF

VP Finishes in builders contract takes preference over finishes specified on plan.


In case of discrepances the author of the plan should be contacted before proceeding
4,430

2,170

with any construction.


(1200x1200)
90

1,200

4,010
W2

LOUNGE
(Tiles)
2,320

900

KITCHEN
1,780

(Tiles) PD26
230

1,000

WM
600
230

230

W5 W6
(900x900) (900x1100)
485 PLASTER & PAINT
785 900 900 895 900 895 37 VAN DER STEL STREET P.O. BOX 1399 TEL: 021 906 6770
KUILSRIVER KUILSRIVER FAX: 021 906 6775
230
1,710
90
3,500
230 ELEVATION 4 7579 7580 EMAIL : nationhousing@mweb.co.za
SCALE 1:100
230 230 230 230 ELECTRICAL
1,710 900 2,230 HOUSE PLAN- Type 2-45 sq.m DATE : AUG 2016
TELEPHONE POINT
5,760 PROPOSED NEW DWELLING DRAWING : Type 2-45sq.m
CEILING LIGHT POINT MONTCLAIR
FOR .......... ON ERF ...... , PROJECT : NATION HOUSING
1 SANS 10400-XA WATERPROOF LIGHT POINT
15 AMP PLUG POINT
MONTCLAIR SCALE : 1:100
HWC DETAILS:
FLOOR PLAN PIPING 15mm AND 22mm CLASS 1
COPPER TUBE
15 AMP UNDERCOUNTER
SCALE 1:100 MOUNT PLUG POINT
HWC KWIKOT ECONO STD GALV. 150L
AREA HOUSE : 45 sq.m GEYSER. 15 AMP PLUG POINT 2000mm HIGH
WALLS EXT. 230 CAVITY LAGGING (R=1) ON ALL EXPOSED PIPES
1200mm HIGH PC WALL
DISTRIBUTION BOARD
INT. 90 x 190 mm W2= 1.2x1.2 = 1.44 sq.m
BUILDING LINES W3= 0.6x0.9 = 0.54 sq.m TV TV POINT
RAINWATER CHANNEL NOTE: W5 = 0.9 x 0.9 = 0.81 sq.m
RAINWATER D.P. DP FFL ABOVE NGL TO BE W6= (0.9x1.1) x 3 = 2.97 sq.m STOVE CONNECTION
TOTAL = 5.76 sq.m
110mm PVC SEWER DETERMINED ON SITE. FLOOR AREA : 43 sq.m
AT 1:40 GRADIENT MINIMUM 150mm. FENESTRATION PERCENTAGE : 13.40 % BALL FITTINGS TO ALL LIGHT POINTS