Está en la página 1de 7

CALCULOS ELECTRICOS

PLANTA BAJA
CIRCUI LUGAR CANTIDAD ESPECIFICACI RESULTADOS
TO ONES
C1
5 Contactos 180 VA 5 X 180 VA = 900
ESTANCIA VA
Y 4 Focos de 23W 4 x 23 W ( 1.05 )
=101.7 VA
COMEDOR pared 0.95

C1
3 Contactos 180 VA 3 X 180 VA = 540
Cocina VA
1 Foco de pared 23W 1 x 23 W ( 1.05 )
=25.42 VA
0.95

C1
Bao 1 Contacto 180 VA 1 X 180 VA = 180
VA
1 Foco de pared 23W 1 x 23 W ( 1.05 )
=25.42 VA
0.95
PLANTA ALTA

C2

2 Foco de pared 23W 2 x 23 W ( 1.05 )


=50.84 VA
Pasillo 0.95

C2
2 Contactos 180 VA 2 X 180 VA = 360
Recamara 1 VA
1 Foco de pared 23W 1 x 23 W ( 1.05 )
=25.42 VA
0.95

C2
Recamara 2 2 Contactos 180 VA 2 X 180 VA = 360
VA
1 Foco de pared 23W 1 x 23 W ( 1.05 )
=25.42 VA
0.95

C2
4 Contactos 180 VA 4 X 180 VA = 720
Recamara 3 VA
1 Foco de pared 23W 1 x 23 W ( 1.05 )
=25.42 VA
0.95

TOTAL DE CARGA = 3339.7 VA

Carga de fusibles
127V X 15A = 1905 A
127V X 20A = 2540 A

Carga total 3339.7


N de Cicuitos= = = 1.75
Carga de A 1905
3339.7
= 1.31
2540

POR LO TATO REALIZAMOS 2 CIRCUITOS


BALANCEANDO LAS CARGAS
C1= 1772.54 VA
C2= 1567.16 VA

Para C1
P 1772.54
I= = = 13.95 A
V 127 V

Conducto Conduce FcT FcA Conduce


r
12 AWG 20 A 1 1 16 A

4 LI 4 (17 m)(13.95)
e= = = 2.2565
SEn ( 3.31)(127)

Para C2
P 1567.16 VA
I= = = 12.3398 A
V 127V

Conducto Conduce FcT FcA Conduce


r
12 AWG 20 A 1 1 16 A

4 LI 4 (14 m)(12.3398 A)
e= = = 1.6438
SEn ( 3.31)(127)

Para C3 Cocina (PAE)


I = 3A X 3 = 9 A
4 LI 4 (7 m)(9.0 A)
e= = = 0.5994
SEn (3.31)(127)

Para C4 Estancia - Comedor (PAE)


I = 3A X 4 = 12 A

4 LI 4 (17 m)(12 A)
e= = = 1.9411
SEn (3.31)(127)

Para C5 Microondas
I = 13 A
4 LI 4 (7 m)(13 A)
e= = = 0.8659
SEn ( 3.31)(127)

Para C6 Centro de lavado


I = 13 A
4 LI 4 (14 m)(13 A)
e= = = 1.7318
SEn ( 3.31)(127)

Factor de demanda
Consideramos PAE = 1500 VA

C1=1772.54 VA
C2=1567.16
C3= 1500
C4= 1500
C5=
C6= 1500
__________________
= 6, 339.7 VA
F.D = (3000) (1) + (Carga total - 3000) (0.35)
= (3000) (1) + (6339.7 3000) (0.35)
= 4168.895 VA
= 4168.895 VA + C5 Microondas
= 4168.895 VA + (13 A) (127 V)
= 4168.895 VA + 1651 VA
= 5819.895 VA

Calculo del alimentador

P = VI
P 5819.895 VA
I = 2 En = 2(127V ) = 22.9129A = 30 A

Conducto Conduce FcT FcA Conduce


r
10 AWG 30 A 1 1 30 A
(Mximo)

C1 e% =
2.2565
C2 e% =
1.6438
C3 e% = 0.5994
C4 e% = 1.9411
10 AWG
C C5 e% = 0.8659
C6 e% = 1.7328

e% < e% < e% = 5 2.2565% = 2.7435

e% <

e% = e% =

Distribucin de fases
FASES
C1= 1772.54 VA A B
C2=1567.16 VA 177
C3= 1524 VA 2.54
C4= 1524 VA 156
C5= 1651 VA 7.16
C6= 1651 VA 114
3
C3=C4= 9X127= 1524 114
C5=C6= 13X127= 3 1651
165
1
165
1
456 436
6.54 1.16
Fase ms cargadaFase menos cargada
Desbalanceo= x 100 =
Fase ms cargada
4566.544361.16
x 100=4. 49
4566.54