Product Summary
Operating voltage
On-state resistance
Nominal current
Load current (ISO)
Current limitation
Package
Features
Vbb(on)
5.5 ... 38
RON
IL(nom)
IL(ISO)
10 m
8
A
33
A
75
A
IL12(SC)
PG-TO252-5-11
(DPAK 5 pin; less than half the size as TO 220 SMD)
Diagnostic Function
Proportional load current sense (with defined fault signal in case of overload operation, overtemperature
shutdown and/or short circuit shutdown)
Application
Power switch with current sense diagnostic feedback for 12V and 24 V DC grounded loads
All types of resistive, inductive and capacitive loads
Replaces electromechanical relays, fuses and discrete circuits
General Description
N channel vertical power FET with charge pump, current controlled input and diagnostic feedback with load
current sense, integrated in Smart SIPMOS chip on chip technology. Providing embedded protective functions.
3 & Tab
R
Voltage
source
Voltage
sensor
Overvoltage
Current
Gate
protection
limit
protection
Charge pump
Level shifter
Rectifier
IN
Logic
ESD
I IN
Limit for
unclamped
ind. loads
Output
Voltage
detection
+ V bb
bb
OUT
1, 5
IL
Current
Sense
Load
Temperature
sensor
IS
PROFET
I IS
Load GND
VIN
V IS
IS
Logic GND
Data Sheet
1 of 18
Pin
Symbol
Function
OUT
IN
Tab/(3)
Vbb
Supply Voltage; positive power supply voltage; tab and pin3 are internally
shorted.
IS
OUT
*) Not shorting all outputs will considerably increase the on-state resistance, reduce the peak current capability
and decrease the current sense accuracy
Symbol
Vbb
Vbb
VLoad dump2)
Values
IL
Tj
Tstg
Ptot
self-limited
-40 ...+150
-55 ...+150
59
A
C
EAS
0.3
VESD
3.0
kV
+15, -120
+15, -120
mA
self-limited
20
V/s
IIN
IIS
38
30
45
Unit
V
V
V
1)
2)
3)
4)
Short circuit is defined as a combination of remaining resistances and inductances. See schematic on
page11.
VLoad dump is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839.
See also diagram on page 11.
See also on page 8. Slew rate limitation can be achieved by means of using a series resistor RIN in the input
path. This resistor is also required for reverse operation. See also page 10.
Data Sheet
2 of 18
Thermal Characteristics
Parameter and Conditions
Symbol
Thermal resistance
min
----
Values
Unit
typ
max
-1.1 K/W
80
-45
55
Electrical Characteristics
Parameter and Conditions
Symbol
Values
min
typ
max
Unit
Tj=25 C: RON
Tj=150 C:
---
10
18
14
24
VON(NL)
----
8
14
30
10
18
65
IL(ISO)
IL(nom)
ton
toff
33
8
---
41
10
250
250
--500
500
dV /dton
--
0.3
0.5 V/s
-dV/dtoff
--
0.3
0.6 V/s
Tj=25 C:
Tj=150 C:
Output voltage drop limitation at small load
currents (Tab to pin 1,5) 5)
Tj=-40...150 C:
Nominal load current (Tab to pin 1,5)
ISO Proposal: VON 0.5 V, TC = 85C, Tj 150C
SMD 6), VON 0.5 V, TA = 85C, Tj 150C
Turn-on time
to 90% VOUT:
Turn-off time
to 10% VOUT:
RL = 2.2 , Tj=-40...150 C
Slew rate on
25 to 50% VOUT, RL = 2.2 , Tj=-40...150 C
Slew rate off
50 to 25% VOUT, RL = 2.2 , Tj=-40...150 C
mV
5)
6)
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm2 (one layer, 70m thick) copper area for Vbb
connection. PCB is vertical without blown air.
Data Sheet
3 of 18
A
s
Symbol
min.
Operating Parameters
Operating voltage (VIN=0)
Tj=-40...150 C: Vbb(on)
Undervoltage shutdown 7) 8)
VbIN(u)
Undervoltage restart of charge pump
Vbb(ucp)
Overvoltage protection 9)
Ibb=15 mA
Standby current
IIN=0
Values
typ.
Unit
max.
5.5
---
-2.5
4
38
3.5
5.5
63
67
--
---
3
6
6
14
--
--
16
---
9.5
16
13
22
---
9
15
12
20
--
100
150
---
700
300
---
mV
--
--
ms
VZ,IN
Tj=-40...+150C:
Tj=-40...+120C: Ibb(off)
Tj=150C:
V
V
V
V
Reverse Battery
Reverse battery voltage 10)
-Vbb
7)
Data Sheet
4 of 18
Symbol
Values
min.
IL6(SC)
typ.
Unit
max.
--70
--45
--33
--20
--15
110
105
90
80
75
60
60
55
50
40
40
35
25
25
25
140
--110
--80
--60
--40
---
VON(SC)
2.5
3.5
4.5
td(SC1)
350
650
1200
td(SC2)
--
--
VON(CL)
39
42
--
150
--
175
10
---
C
K
IL12(SC)
IL18(SC)
IL24(SC)
IL30(SC)
Tjt
Tjt
A
A
A
A
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
13) Short circuit current limit for max. duration of t
d(SC1) , prior to shutdown, see also figures 3.x on page 13.
14) Not subject to production test, specified by design.
15) See also figure 2b on page 12.
12)
Data Sheet
5 of 18
Symbol
Values
min.
Diagnostic Characteristics
Current sense ratio, static on-condition
kILIS = IL : IIS, IIS < IIS,lim 16),
VIS <VOUT - 5 V, VbIN > 4.5 V
kILIS
IL = 30A, Tj = -40C:
Tj = +25C:
Tj = +150C:
IL = 7.5A, Tj = -40C:
Tj = +25C:
Tj = +150C:
IL = 2.5A, Tj = -40C:
Tj = +25C:
Tj = +150C:
IL = 0.5A, Tj = -40C:
Tj = +25C:
Tj = +150C:
IIN = 0 (e.g. during deenergizing of inductive loads):
typ.
Unit
max.
-- 10 000
--
8300
8300
8300
7500
8000
8200
7100
7700
8000
5000
5500
6000
10000
9700
9300
10000
9700
9300
10000
9700
9300
12000
12000
12000
11000
10600
10000
11400
10800
10200
13400
12500
12000
21000
19000
18000
--
--
Tj = -40...+150C:
IIS,fault
4.0
5.2
7.5
mA
Tj = -40...+150C:
IIS,lim
4.0
6.0
7.5
mA
350
650
1200
IIS(LL)
--
0.1
0.5
IIS(LH)
--
0.1
IL(MIN)
50
--
--
mA
--
250
500
--
50
100
63
67
--
VIN = 0, Tj = -40...+150C
Current sense settling time to IIS static after input
current positive slope, 18)
tson(IS)
IL = 0
20 A, Tj= -40...+150C
Current sense settling time during on condition, 18)
IL = 10
20 A, Tj= -40...+150C
tslc(IS)
Overvoltage protection
Tj = -40...+150C: VZ,IS
Ibb = 15 mA
16)
Data Sheet
6 of 18
Symbol
min.
Input
Required current capability of input switch
IIN(on)
Tj =-40..+150C:
Input current for turn-off
Tj =-40..+150C: IIN(off)
Data Sheet
Values
7 of 18
typ.
Unit
max.
--
1.4
2.2
mA
--
--
30
Truth Table
Input
Current
level
L
H
L
H
L
H
L
H
L
H
L
H
Normal
operation
Overload 19)
Short circuit to GND 20)
Overtemperature
Short circuit to Vbb
Open load
L = "Low" Level
H = "High" Level
Output
level
L
H
L
H
L
L
L
L
H
H
Z
H
Current
Sense
IIS
0 (IIS(LL))
nominal
0 (IIS(LL))
IIS,fault
0 (IIS(LL))
IIS,fault
0 (IIS(LL))
IIS,fault
0 (IIS(LL))
<nominal 21)
0 (IIS(LL))
0 (IIS(LH))
Terms
I bb
3
VbIN
VON
Vbb
IL
bb
OUT
IN
PROFET
RIN
V
IN
I IN
1,5
IS
VbIS
I IS
DS
VIS
VOUT
R IS
19)
Overload is detected at the following condition: 1V (typ.) < VON < 3.5V (typ.) . See also page 11.
Short Circuit is detected at the following condition: VON > 3.5V (typ.) . See also page 11.
21) Low ohmic short to V may reduce the output current I and therefore also the sense current I .
bb
L
IS
20)
Data Sheet
8 of 18
V bb
R bb
ZD
VZ1
ON
Z,IN
V bIN
OUT
IN
I
PROFET
IN
+ Vbb
Vbb
Rbb
ZD
R bb
V Z,IN V
Z,IS
Normal operation
IN
Logic
V OUT
Z,IS
IIS,fault
PROFET
IS
IS
R
IIS
V
R
IS
IS
Z,VIS
Signal GND
IS
Vbb 5V
.
7.5mA
Note: For large values of RIS the voltage VIS can reach
almost Vbb. See also overvoltage protection.
If you don't use the current sense output in your
application, you can leave it open.
Data Sheet
9 of 18
bb
IN
Version a:
OUT
R IN
Power
Transistor
Logic
bb
V
IN
bb
PROFET
OUT
RL
D
IS
R IS
Signal GND
VD
Power GND
V ZL
0.08 A
1
1
+
=
RIN RIS
| Vbb | 12V
V bb
- IL
IN
PROFET
V OUT +
IS
OUT
IIS
V IN
V IS
R IS
10 of 18
Overload detection
Fault Condition: VON > 1 V typ.
i L(t)
V bb
+ V bb
ELoad
bb
IN
VO N
PROFET
IS
OUT
IN
ZL
RIS
detection
circuit
Logic
unit
OUT
L
RL
EL
ER
EL = 1/2LI L
Short circuit
5uH
bb
OUT
EAS=
L SC
IN
IL L
(V + |VOUT(CL)|)
2RL bb
ln (1+ |V
ILRL
OUT(CL)|
PROFET
10mOhm
IS
I
R SC
IN
SC
V bb
1000
L SC
24V
V bb : 16V
18V
L [m H ]
100
10
30V
10
5
0,1
R SC
0
0
100
200
300
[mOhm]
0,01
1
Data Sheet
11 of 18
10
I_L [A ] 100
Timing diagrams
Figure 2a: Switching motors and lamps:
IIN
IIN
VOUT
VOUT
90%
dV/dtoff
t on
IIL
dV/dton
t off
10%
IL
tslc(IS)
t slc(IS)
IIS
IIS,faut
/ I IS,lim
t
Load 1
IIS
tson(IS)
Load 2
t soff(IS)
IIN
VOUT
VON(CL)
IL
IIS
t
Data Sheet
12 of 18
I L(SC)
IIN
100
IL
80
60
td(SC2)
depending on the
external impedance
VON
40
1V typ.
20
IIS
V ON
0
0 V
10
20
ON(SC)
30
IL
k ilis
[V]
IS,fault
IIN
IL
IIN
VON > VON(SC)
IL(SC)
IIS
IIS,fault
td(SC1)
tm
VOUT
Auto Restart
IIS
I
IS,fault
tdelay(fault)
Tj
Data Sheet
13 of 18
IIN
IL
Vbb -V OUT
I L,lim
VON=1V typ.
RON *I L,lim
IS
t
IL
k ilis
IIS,lim
I IS(LH)
0
IL
IL(MIN) 10
IIS,fault
20
30
40
[A]
kILIS
VOUT
20000
VIN = 0
15000
10000
dynamic, short
Undervoltage
not below
ON(CL)
VbIN(u)
5000
IIN = 0
[A] IL
0
10
20
VON(CL)
0
0
V bIN(u)
V bIN(ucp)
10
V12
bb
22
Data Sheet
14 of 18
[V]
0.1
VON
ON
V
ON(NL)
0.05
IL
0.0
0
Data Sheet
7 [A] 8
15 of 18
Package Outlines
All dimensions in mm
BTS 6143 D
Green Product
To meet the world-wide customer requirements for environmentally friendly products and to be compliant with
government regulations the device is available as a green product. Green products are RoHS-Compliant (i.e Pbfree finish on leads and suitable for Pb-free soldering according to IPC/JEDEC J-STD-020).
Data Sheet
16 of 18
Revision History
Version
Date
Changes
Rev. 1.0
2007-02-21
Data Sheet
17 of 18
Edition 2007-02
Published by
Infineon Technologies AG
81726 Munich, Germany
Infineon Technologies AG 2007.
All Rights Reserved.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or
characteristics (Beschaffenheitsgarantie). With respect to any examples or hints given herein, any typical
values stated herein and/or any information regarding the application of the device, Infineon Technologies
hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of noninfringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the
failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life
support devices or systems are intended to be implanted in the human body, or to support and/or maintain and
sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other
persons may be endangered.