Está en la página 1de 4
ECP ssn Omeeoe | Professional Audio LPR 35 1/4 inch long play standard bias studio tape with black backcoating, Derived from SM 911. Designed specifically for institutional and semi professional > low speed recording (7,5 and 3,75 ips), Offering » wide dynamic range, » high level uniformity up to the highest frequencies » excellent winding properties. Audio Studio MG ernational Technical Data Professional Audio LPR 35 1. Recording Performance Specifications (depending on bias settings) ‘Tape speed 19.05 crs Recording head gap length 7.0 um Playback head gap length = 3.0 um Equalsation 70 us Reference level 320 nWb/m. { i zg = © a0 i 45 Son 4D a8 20 25 30 35 45 0 $5 45 Bos i os 0 oz o ‘Tape speed 19.05 ons Recording head gap length 7.0 um Playback head gaplengt 3.0 um Equalisaton 50 + 3180 ps Reference level 320 nWb/m a8 +10; su ° eo = : 1 1 4s a ™ as : Ee : 35: : « i oe os w | e a . 4s a Bios (48) ‘Tape speed 9.53cm/s Recording head gaplength 7.0 pm Playback head gap length 3.0mm. Equalisation 90 + 3180 ps Reference level 250 nWb/m +15) 10; +s S50 ae 25 20 35 0) 8 oe bios a8) = (02) 04/06 Technical Data Professional Audio LPR 35 2. Measurement conditions ‘Tape speed Recording head Gap length Track width Payback head Gap length Track wieth Playback equalisation Roe Reference level (315 kt) Plec Reference level (1 KHz) TEC reference tape: batch Reference tape bias defintion RB EC reference bias Rec, Blas Recommended bias setting ‘ASisSensitivity drop for ‘AS recommended bias setting 3. Recor ing performance specifications 19.05 cm/s 7Sin/s 7.0 um 6am 3.0 um 2.575 mm 70s 320 nWo/m 3420 Min. 7H0320 0.048, 0.048 4068 19.05 cm/s, 7Sin/s 7.0 un 63mm 3.0 um 2.575 mm 5043180 ps 320 nwb/m, C2642 in, THO320 0.048 4.008 9.53 am/s 3.75 in/s 7.0 ym 63mm 3.0 ym 2575 mm 9043180 ys 250 ney 2642 Min, THO250 0.068 asap ‘The table below pragents the maln parameters in the recommenced blas setting. Al figures given represent nominal values. Mola Molin Sob. SOL SOL Sus s. Sus Se Su Sie TOs THO THO» THO DeN Nee Nx MOWEN MOUENacx P Maximum output level at 315 Hz Maximum output level at 1 kz ‘Saturation output level at 10 kez ‘Saturation output level at 14 ke ‘Saturation output level at 16 kez Relative tape sensitivity at 315 Hz Relative tape sensitivity at 1 Kitz Relative tape sensitivity at 6,3 Kitz Relative tape senstvty at 10 kez Relative tape sonstvity at 14 ki Relative tape sensitivity at 16 kHz “Third harmonic distortion level at 250 n/m “Third harmonic distortion factor at 250 nWVb/m “Third harmonic distortion level at 320 nm “Third harmonic distortion factor at 320 nWVb/m DC noise, weighted, rel: Rise Bis noise level (IEC 94; A curve) Bias noise level (CCIR 468-3) ‘Signal to bias noise at 1 KHz ‘Signal to bias noise at 1 kHz Printthrough +7508 +5048 “1.08 +1048 +1548 +1048 +1048 47.048 0.44% 55.08 60.5 48 47.008 68.008 54.508 56.008 47508 42008 4.0.48 41548 42048 +1048 +1048 48.5 48 0.40% 56.048 635 48 50.048 mods 57548 56.048 +0008 4.0 8 1258 41.5 65 41.048 +008 41545 50.0 46 032% “S75 66 esas 56.008 (03) 04/08 1a 12 13 13 14 1s 16 16 2a 2a 22 22 22 23 23 23 23 23 23 24 24 24 24 25 26 26 27 27 28 echnical Data Professional Audio LPR 35 4. Magnetic properties 3.0 HC Coercvty BRS Retentivity ors, Saturation fx 5. Physical properties Base material “Tape width Tolerances of tape width Base thickness Coating thickness Backcoating Total thickness Surface resistance of magnetic coating ‘Surface resistance of matt back Load for elongation of 3% (F 3) Load for elongation of 5% (Fs) Breaking tensile strength (6.3 mm tape width) 6. References Data in this publication are based on test methods of IEC Publication 94, Part S. In as far as any test method isnot part of this publication, reference has been mace. 41.4 Measurement method according to TEC 94, using the TEC Standard reference heads for professional application. For this purpose, recording heads with a gap length of 7 um are ecommended, These magnetic heads have been used for domes recording type measurements, since appropiate heads are stl under discussion. 1.2 Playback equalization onthe tape testing equipment is adjusted to provide a fat frequency response ofthe output voltage when compared withthe frequency response secion ofthe appropriate IEC calibration tape (time constants tl = 70 s ort + 12 = 50+3180 js resp. at tape speed 19.05 anjs, t+t2= 90+3180 ps at tape speed 9.53 cm/s) 1.3 Rac (Reference Level): The reference level 320 nom or 250 nim resp. corresponds withthe reference level section of the IEC calibration tape used. 1.4 Reference tape bas definition: Using the relevant IEC Calration tape and the standard reference heads, the bias current providing the minimum third harmonic cstorton level tthe reference level signal frequency 1 kHz) is the reference bias setting, - IEC reference bias definition for domestic recording, Using reference tape C 264 2, is stil under iscusson Appropriately, the bias current proving the minimum third (02,0408 25.5 kam 3200e 165 mT 1650 1800 nWb/m 180 mM/mm Polyester 63mm sinc ++0/-0.06 mm. +0/-2,4 mil 20.0 um 0.78 mil 4a 11.0 um 0.43 mil at black 35.0 um 1.38 mil 44 $50,000 Ma < 5062 42 100k2 217N 2 79MPa 43 >20N > 92MPa 43 250N 2225 MPa 4a harmonic distortion level atthe reference level (signal frequency ‘315 He) i the reference bias setting 15 RBxc (IEC Reference Bas): This data represents the bias ratio Of the relevant IEC reference tape andthe tape under tet at 19.05 om/s. 1.6 ASz, Sin (Sensitivity drop for recommended bias setting): Operationally, the recommended bias is set with an input signal of 10 kz (19.05 cm/s) or 6.3 kz (9.53 cms) at -20 d8. Based on the senstivty curves AS, oF SLO resp. peak, the bias is increased Lntl the playback level is reduced by the given value ASs; or AS resp (see graph). 2:1 MOL, MOL (Maximum Output Level): Outpt level at 315, Hz (9.53 cmv) or 1 kz (19.05 cm/s) relative to reference level LEC, wth a third harmonic stotion factor of 3 % or THD 30.508. 2.2.SOL.n, SOL SOL (Saturation Output Level: Output level 30 kz, 14 kHz or 16 kHz respectively at which saturation occurs, relative to reference level Rc. 2.3 Sny S Sex, Sry Ska Si (Senstvty): Te senstivty aves were recorded sing a constant current with no equalisation. The ‘magnetic tapes 1 kHz (19.05 om/s) oF 315 Hz (9.53 cm/s) input signal is approximately 20 dB below the reference evel RL xc. In ‘xcordance with TEC publication 94 the values for relative tape ‘Sensitvty refer to those of the relevant reference tape (batch A [342 D or C264 Z resp.) atts ovn reference bias. ~ The distance between the senstivty curves Sus oF S and Ses, Sy Su 0 Sux resp. reflects the recording equalisation necessary to achieve a lt frequency response.

También podría gustarte