Está en la página 1de 4

PREDIMENSIONAMIENTO

ALTURA DE PISOS=
ESPESOR EFECTIVO DE MUROS:

2.6 m
0.13 m

h/20=

ENTONCES ESPESOR DE MUROS ES:

0.15 m

DENSIDAD MINIMA DE MUROS REFORZADOS


Z=
U=
S=
N=

0.4
1
1
4 Numero de pisos
(Lxt) /Ap mayor o igual que:

0.029

DIMENSIONES DE LA PLANTA TIPICA


LARGO:
ANCHO:

16.75 m
8.15 m
Ap=

Muro
X1
X2
X3
X4
X5
X6
X7

136.5125 m2

L(m)
3.13
1.5
3.13
3.1
3.13
2.6
2.73

t(m)
0.13
0.13
0.13
0.13
0.13
0.13
0.13

(Ac X Nm)/Ap =

TABLA DE DENSIDAD
Ac(m2)
Nm
0.407
0.195
0.407
0.403
0.407
0.338
0.355

DE MUROS REFORZADOS
Muro
2 Y1
2 Y2
2 Y3
2 Y4
2 Y5
2 Y6
1 Y7

0.034

Nota: si algun muro es de concreto el valor de t sera: tc (Ec/Em)

VERIFICACION DEL ESFUERZO AXIAL POR CARGAS DE GRAVEDAD


fm=

650 Tn/m2

Fa = 0.2 fm [ 1 - (h/35t)2] =
0.15 fm

REVISAR CON MURO MAS CARGADO

87.55
97.5 debe ser mayor

AMIENTO

UROS REFORZADOS
L(m)
2.6
2.6
3.1
3.1
3.1
3.1
4.13

t(m)
0.13
0.13
0.13
0.13
0.13
0.13
0.13

(Ac X Nm)/Ap =

DE GRAVEDAD

Ac(m2)
0.338
0.338
0.403
0.403
0.403
0.403
0.537
0.037

Nm
2
2
2
2
2
2
1

e ser mayor

También podría gustarte