TECHNICAL BULLETIN
MIXING INSTRUCTIONS
P1W
HMIS INFORMATION
Hazardous Materials Identification System. Please
refer to Section 3 in the MSDS for further
information.
Part A
Concentrate
Part B
Working
Tank
Health
Flammability
Reactivity
Personal
Protection
All CP48
Frontiers
All CP48
Frontiers
All CP48
Frontiers
38.5 0.3 C
101.3 0.5 F
40mls/m
P1 = 45
SHELF LIFE
Concentrate
Part A
Time
Color
Odor
Working
Part B
U = 24 Months
O = 2 Weeks
Clear,
Yellow
U = 24 Months
O = 2 Weeks
Clear,
Colorless
Slight Odor
Slight Odor
Tank
2 Weeks
Working
Tank
Concentrate
Water
Pour 3
liters of
Water
(30-40 C)
into
measuring
bottle
Part A
Part B
Add 1
Bottle
P1A to the
measuring
bottle
Add 1
Bottle
P1B to the
measuring
bottle
Pour
Solution
into Sub
Tank
Circulation
Filter
Frontier 330
Repeat the above instructions 2
times and top Sub Tank with an
additional 2 Liters of water.
Frontier 350
Repeat the above instructions 3
times and top Sub Tank with an
additional 1.5 Liters of water.
Frontier 370
Repeat the above instructions 4
times and top Sub Tank with an
additional 1.5 Liters of water.
Frontier 390
Repeat the above instructions 12
times and top Sub Tank with an
additional 10.7 Liters of water.
Clear,
Yellow
No Odor
U = Unopened, O = Opened
The data contained in this photographic bulletin is believed to be true and accurate, but is offered solely for your consideration, investigation, and
verification. Nothing herein shall be construed to be a warranty or guarantee by either FUJIFILM Hunt Chemicals Inc. or any of its affiliates, and all such
warranties, implied or otherwise, including any implied warranty of merchantability, are hereby expressly disclaimed. You, of course, are fully
responsible for any use and / or domestic or foreign sale of the product(s) described, and nothing in this photographic bulletin shall be construed to
constitute permission or a recommendation to practice any invention covered by patent or patent application or know-how owned by FUJIFILM, its
affiliates, or others.
TECHNICAL BULLETIN
MIXING INSTRUCTIONS
To Make CP49 Working Tank Solution
P1W
Concentrate
Water
Part A
Top Off
With
Water
Part B
See reverse
HMIS INFORMATION
See reverse
Working
Tank
42 C 0.03
C (107.6 F)
43 C 0.3 C
(109.4 F)
40ml/m
19
22
750
28
Pour 2.5
liters of
Water
(30-40 C)
into
measuring
bottle
Add 1
Bottle P1A
to the
measuring
bottle
Add 1
Bottle P1B
to the
measuring
bottle
Add 470mls
water to
make a total
of 3.7L of
solution.
Pour mix
into Sub
Tank.
Temperature
Replenishment
Rate
Processing
Time
SHELF LIFE
See reverse
25
The data contained in this photographic bulletin is believed to be true and accurate, but is offered solely for your consideration, investigation, and
verification. Nothing herein shall be construed to be a warranty or guarantee by either FUJIFILM Hunt Chemicals Inc. or any of its affiliates, and all such
warranties, implied or otherwise, including any implied warranty of merchantability, are hereby expressly disclaimed. You, of course, are fully
responsible for any use and / or domestic or foreign sale of the product(s) described, and nothing in this photographic bulletin shall be construed to
constitute permission or a recommendation to practice any invention covered by patent or patent application or know-how owned by FUJIFILM, its
affiliates, or others.
Technical Hotline