P=

QHn
75

Ns=

N P
1.25
H

p=

f 60
N

Ns H 1.25
N=
P

H = 348.41 m
Q = 10 m3 /s
P=

103 10 348.41 0.85


=39486 CV
75
Ns=

N = 450 RPM
p=

450 39486
=60
1.25
348.41

60 60
=8 pares de polos
450

Si turbina francis ---> Ns = 120


N=

p=

120 348.41
39486

1.25

=909 RPM

60 60
=4 pares de polos
909

P=

QHn
75

Ns=

N P
1.25
H

p=

f 60
N

Ns H 1.25
N=
P

H = 72 m
Q = 20.11 m3 /s
P=

103 20.11 72 0.85


=16410 CV
75
Ns=

N = 257 RPM
p=

257 16410
=60
1.25
72

60 60
=14 pares de polos
257

Si turbina kaplan ---> Ns = 482


1.25

N=

p=

482 72
=790 RPM
16410

60 60
=5 pares de polos
790

P=

QHn
75

Ns=

N P
1.25
H

p=

f 60
N

Ns H 1.25
N=
P

H = 18.5 m
Q = 30 m3 /s
P=

103 30 18.5 0.85


=6290 CV
75
Ns=

N = 275 RPM
p=

275 6290
=568
1.25
18.5

60 60
=13 pares de polos
275

Si turbina francis ---> Ns = 288


N=

p=

288 18.5
6290

1.25

=140 RPM

60 60
=26 pares de polos
140

P=

QHn
75

Ns=

N P
1.25
H

p=

f 60
N

Ns H 1.25
N=
P

H = 119 m
103 3.25 119 0.85
=4384 CV
75

Q = 3.25 m /s

P=

N = 720 RPM

Ns=

p=

720 4384
=121
1.25
119

60 60
=5 pares de polos
720

Si turbina pelton ---> Ns = 102


1.25

102 119
N=
4384

p=

=606 RPM

60 60
=6 pares de polos
606

P=

QHn
75

Ns=

N P
1.25
H

p=

f 60
N

Ns H 1.25
N=
P

H = 253.85 m
Q = 32 m3 /s
P=

103 32 253.85 0.85


=92063 CV
75
Ns=

N = 200 RPM
p=

200 92063
=60
1.25
253.85

60 60
=18 pares de polos
200

Si turbina Francis ---> Ns = 157


N=

p=

157 253.85
92063

1.25

=524 RPM

60 60
=7 pares de polos
524

También podría gustarte