Está en la página 1de 15

UNIVERSIDAD ANDINA "NESTOR CACERES VELASQUEZ"

FACULTAD DE INGENIERIAS Y CIENCIAS PURAS


LABORATORIO DE MECANICA DE SUELOS, CONCRETO Y ASFALTOS

PROYECTO

: MEJORAMIENTO DE LA CAPACIDAD RESOLUTIVA DEL CENTRO DE SALUD JOSE DOMINGO


CHOQUEHUANCA

FINES
SOLICITANTE
UBICACIN
MUESTRA
CALICATA
PROFUNDIDAD
FECHA

: CIMENTACION
: CORPORACION INCA
: BARRIO SANTA ROSA - JOSE DOMINGO CHOQUEHUANCA
:1
: N 1
: 2.70 mt
: 19 DE ENERO DEL 2015

CONTENIDO DE HUMEDAD
ASTM - D - 2216 - MTC - E 108
gr
gr
gr
gr
gr
%

SUELO HUMEDO + TARRO


SUELO SECO + TARRO
PESO DEL TARRO
PESO DEL AGUA
PESO DEL SUELO SECO
HUMEDAD %

263.05
207.88
37.40
55.17
170.48
32.36

LIMITE LIQUIDO - LIMITE PLASTICO E INDICE DE PLASTICIDAD


ASTM - D424 D-4318
AASHTO - T90
CAPA :
LIMITE LIQUIDO

LIMITE PLASTICO

42.93
38.84
30.36
4.09
8.48
48.23
23

43.91
39.52
30.42
4.39
9.10
48.24
23

47.75

LIMITE PLASTICO %

TARRO N

gr
gr
gr
gr
gr
%

SUELO HUMEDO + TARRO


SUELO SECO + TARRO
PESO DEL TARRO
PESO DEL AGUA
PESO DEL SUELO SECO
HUMEDAD %
N DE GOLPES

LIMITE LIQUIDO %

INDICE PLASTICO %

14

10.76
9.50
6.24
1.26
3.26
38.65

10.80
9.54
6.31
1.26
3.23
39.01

38.83
08.92

LL = Wn * (N/25)^0.121
Donde:
LL = Limite Liquido
Wn = Contenido de Humedad Promedio (%)
N = Numero de Golpes
OBSERVACIONES: LAS MUESTRAS FUERON PUESTAS EN LABORATORIO POR EL SOLICITANTE

FN: 003537

UNIVERSIDAD ANDINA "NESTOR CACERES VELASQUEZ"


FACULTAD DE INGENIERIAS Y CIENCIAS PURAS
CARRERA ACADEMICO PROFESIONAL DE INGENIERIA CIVIL
LABORATORIO DE MECANICA DE SUELOS, CONCRETO Y ASFALTOS

ANALISIS GRANULOMETRICO POR TAMIZADO (ASTM D422)


ENSAYOS ESTANDAR DE CLASIFICACION (D422 - D2216 - D4318 - D427 - D2487)
PROYECTO

: MEJORAMIENTO DE LA CAPACIDAD RESOLUTIVA DEL CENTRO DE SALUD JOSE DOMINGO

FINES

: CIMENTACION

SOLICITANTE

: CORPORACION INCA

UBICACIN

: BARRIO SANTA ROSA - JOSE DOMINGO CHOQUEHUANCA

CALICATA

: N 1

CHOQUEHUANCA

PROFUNDIDAD : 2.70 mt
FECHA

: 19 DE ENERO DEL 2015

TAMICES

ABERTURA

PESO

%RETENIDO

%RETENIDO

% QUE

ASTM

mm
76.200
63.500
50.600
38.100
25.400
19.050
12.700
9.525
6.350
4.760
2.380
2.000
1.190
0.840
0.590
0.420
0.300
0.250
0.180
0.149
0.074

RETENIDO

PARCIAL

ACUMULADO

PASA

0.00

0.00

0.00

100.00

2.21

0.63

0.63

99.37

9.33

2.67

3.30

96.70

24.02
11.16

6.86
3.19

10.16
13.35

89.84
86.65

3"
2 1/2"
2"
1 1/2"
1"
3/4"
1/2"
3/8"
1/4"
No4
No8
No10
No16
No20
No30
No40
No 50
No60
No80
No100
No200

MAC - 2

TAMAO MAXIMO:

DESCRIPCION DE LA MUESTRA
P.I.=
350.00
P.L.=
97.43
P.P.=
252.57
%W=
32.36
LIMITES DE CONSISTENCIA:
L.L.=
47.75
L.P.=
38.83
I.P.=
8.92

4.36
46.35
252.57
350.00
72.16

1.25
13.24
72.16
100.00

14.59
27.84
100.00

###

CARACT. GRANULOMETRICAS:
D10= ---Cu ---D30= ---Cc ---D60= ---CLASIFICACION:
I.G. =
SUSCS
AASTHO

BASE
TOTAL
% PERDIDA

85.41
72.16
0.00

: ML
:

OBSERVACIONES:

CURVA GRANULOMETRICA
MALLAS U.S. STANDARD

1 2

10

11 12

13

14

15

16

17 18

19 20

21

100
90
80
70
60
50
40
30
Eje de tamices

20
10

0.010

21

0.100

20

19

18

17

16

15

14

13

1.000

12

11

10

10.0008

0
100.000

% QUE PASA EN PESO

ESPECIF.

TAMAO DEL GRANO EN mm


(escala logaritmica)

FN: 003537

OBSERVACIONES: LAS MUESTRAS FUERON PUESTAS EN LABORATORIO POR EL SOLICITANTE

FN: 003537

CALCULO DE HUMEDAD FINAL


HUMEDADES DE CORTE
SUELO HUMEDO + TARRO
SUELO SECO + TARRO
PESO DEL TARRO
PESO DEL AGUA
PESO DEL SUELO SECO
HUMEDAD %

gr
gr
gr
gr
gr
%

PAS. 1
653.95
552.79
345.32
101.16
207.47
48.76

PAS.2
693.33
579.58
367.30
113.75
212.28
53.58

PAS. 3
667.29
590.93
284.39
76.36
306.54
24.91

CALCULO DE HUMEDAD INICIAL


HUMEDADES DE CORTE
SUELO HUMEDO + MOLDE
PESO SUELO HUMEDO
PESO SUELO SECO
PESO DEL AGUA
HUMEDAD %

gr
gr
gr
gr
%

PAS. 1
526.25
280.50
207.47
73.03
35.20

PAS.2
535.03
289.28
212.28
77.00
36.27

PAS. 3
633.54
387.79
306.54
81.25
26.51

CALCULO DE LA DENSIDAD SECA


DENSIDAD SECA DE CORTE
PESO DE LA MUESTRA SECA
VOLUMEN DE LA MUESTRA
DENSIDAD SECA

gr
gr
gr

PAS. 1
207.47
200.00
1.04

PAS.2
212.28
200.00
1.06

PAS. 3
306.54
200.00
1.53

B.N 0425076

BAJAR

PAREJO
3.84
1.28

PAREJO

100
200

B.N 0425076

UNIVERSIDAD ANDINA "NESTOR CACERES VELASQUEZ"


FACULTAD DE INGENIERIAS Y CIENCIAS PURAS
ESCUELA PROFESIONAL INGENIERIA CIVIL
Laboratorio de Mecanica de Suelos

ENSAYO
ENSAYODE
DECORTE
CORTE
DIRECTO
DIRECTO
(NORMA ASTM - D3080)
(NORMA ASTM - D3080)

Construccin de carretera de la sda. Arequipa - Cerro Espinal

PROYECTO
FINES
MUESTRA
UBICACIN
CALICATA
Profundidad (m)
Clasificacion (AASHTO)
Estado de la muestra

TALUDES
:1
: BARRIO SANTA ROSA - JOSE DOMINGO CHOQUEHUANCA
: N 1
1.20mts.

NF:

A-2-7
: INALTERADA

DATOS DEL ESPECIMEN


Altura (h)
Area (A)
Densidad Seca (yd)
Humedad (w)
Esfuerzo Normal

(cm)
(cm2)
(gr/cm3)
(%)
(Kg/cm)

ESPECIMEN 01
Deforma
c.
Tangenci
al (mm)

0.00
0.10
0.20
0.30
0.40
0.60
0.80
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.50
4.00
4.50
5.00
5.50
6.00
6.50

Dial de
Carga

0.00
5.50
6.30
7.00
9.30
14.00
16.50
22.50
26.00
30.10
32.40
34.20
35.80
37.40
38.60
39.40
40.00
39.20
38.10
34.60

Esf. Maximos

ESPECIMEN 02

Deforma
Fuerza Esfuerzo
c.
Cortante de Corte
Tangenci
(Kg)
(Kg/cm)
al (mm)

0.000
5.500
6.300
7.000
9.300
14.000
16.500
22.500
26.000
30.100
32.400
34.200
35.800
37.399
38.599
39.399
39.999
39.199
38.099
34.600

ESPECIMEN 01 ESPECIMEN 02 ESPECIMEN 03


Inicial
Final
Inicial
Final
Inicial
Final
2.00
2.00
2.00
2.00
2.00
2.00
100.00 100.00 100.00 100.00 100.00 100.00
2.69
2.36
2.67
30.00
42.50
34.89
38.21
34.21
36.73
1.00
2.00
3.00

0.000
0.055
0.063
0.070
0.093
0.140
0.165
0.225
0.260
0.301
0.324
0.342
0.358
0.374
0.386
0.394
0.400
0.392
0.381
0.346

0.400

0.00
0.10
0.20
0.30
0.40
0.60
0.80
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.50
4.00
4.50
5.00

Dial de
Carga

0.00
10.60
13.80
16.20
17.00
20.50
26.00
28.10
31.70
34.40
35.00
37.80
38.60
40.20
42.90
44.00
46.30
48.10
49.90
46.00
44.30
43.40

ESPECIMEN 03

Deforma
Fuerza Esfuerzo
c.
Cortante de Corte
Tangenci
(Kg)
(Kg/cm)
al (mm)

0.000
10.600
13.800
16.200
17.000
20.500
26.000
28.100
31.700
34.400
35.000
37.799
38.599
40.199
42.899
43.999
46.299
48.099
49.899
45.999
44.299
43.399

0.000
0.106
0.138
0.162
0.170
0.205
0.260
0.281
0.317
0.344
0.350
0.378
0.386
0.402
0.429
0.440
0.463
0.481
0.499
0.460
0.443
0.434

0.499

0.00
0.10
0.20
0.30
0.40
0.60
0.80
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.50
4.00
4.50
5.00
5.50
6.00
6.50

Dial de
Carga

0.00
14.80
18.90
21.60
24.60
27.00
32.80
37.10
39.50
42.40
44.60
46.00
47.40
48.10
50.80
52.20
54.60
56.00
57.80
58.20
57.20
55.10
53.40

Fuerza Esfuerzo
Cortante de Corte
(Kg)
(Kg/cm)

0.000
14.800
18.900
21.600
24.600
27.000
32.800
37.099
39.499
42.399
44.599
45.999
47.399
48.099
50.799
52.199
54.599
55.999
57.799
58.199
57.199
55.099
53.399

0.000
0.148
0.189
0.216
0.246
0.270
0.328
0.371
0.395
0.424
0.446
0.460
0.474
0.481
0.508
0.522
0.546
0.560
0.578
0.582
0.572
0.551
0.534

0.582

FN: 003537

ESFUERZO vs DEFORMACION

0.700

Esfuerzo de Corte (Kg/cm)

0.600
0.500
0.400
0.300
0.200

1.0
Kg/cm

0.100
0.000
0.00

1.00

Deformacion
Tangencial
2.00
3.00
4.00
5.00 (mm)
6.00

7.00

Esf. Cort.Esf. Nor.


1.00
0.400
2.00
0.499
3.00
0.582

ESFUERZO DE CORTE vs ESFUERZO NORMAL


Esfuerzo de Corte (Kg/cm)

0.700
0.600
0.500
0.400
0.300
0.200
0.100
0.000
0.50

1.00

1.50

2.00

2.50

Esfuerzo Normal (Kg/cm)

3.00

3.50

calculo de angulo de friccion

=tan^(-1)(f)

=
21.8
calculo de la cohesion

f=C+tan

FN: 003537

C = 0.18

FN: 003537

UNIVERSIDAD ANDINA "NESTOR CACERES VELASQUEZ"


FACULTAD DE INGENIERIAS Y CIENCIAS PURAS
C.A.P. INGENIERIA CIVIL
Laboratorio de Mecanica de Suelos

ENSAYO
DE
ENSAYO
DECORTE
CORTEDIRECTO
DIRECTO
(NORMA ASTM - D3080)
(NORMA ASTM - D3080)

PROYECTO

0
CHOQUEHUANCA

FINES

: CIMENTACION

SOLICITANTE
PROF.
MUESTRA
FECHA

#REF!
: 2.70 mt
:1
#REF!

NF:

Calicata

: N 1

Profundidad (m)
Clasificacion (SUCS)
Estado de la muestra

1.20mts.
: ML
: INALTERADA

Veloc. De Ensayo (mm/min)

0.700

ESFUERZO vs DEFORMACION

f(x) =

8.100
Esfuerzo de Corte (Kg/cm)

Esfuerzo de Corte (Kg/cm)

Resist. Maxima
C= 0,19Kg/cm
= 21.80

10.100

0.500
0.400
0.300
1.0
Kg/cm
2.0
Kg/cm

0.200
0.100
0.000
0.00

ESFUERZO DE CORTE vs ESFUERZO NORMAL

12.100

0.600

#REF!

6.100
4.100
2.100
0.100

1.00

2.00
3.00
4.00
5.00
6.00
Deformacion Tangencial (mm)

7.00

0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5 10.5
1 2 Esfuerzo
3 4 Normal
5 6 (Kg/cm)
7 8 9 10

FN: 0033537

OBSERVACIONES: LAS MUESTRAS FUERON PUESTAS EN LABORATORIO POR EL SOLICITANTE

0.254

0.332

0.586

0.1722

FN: 0033537

0.3498

0.252

0.1147

0.367

FN: 0033537

0.384071556
2.6036814862
0.363

FN: 0033537

CALCULO DE CAPACIDAD PORTANTE DE ZAPATAS CUADRADAS


CALCULO DE CAPACIDAD PORTANTE DE ZAPATAS CUADRADAS

PROYECTO

: MEJORAMIENTO DE LA CAPACIDAD RESOLUTIVA DEL CENTRO DE SALUD JOSE DOMINGO


CHOQUEHUANCA

FINES
SOLICITANTE

: CIMENTACION

UBICACION
FECHA

: BARRIO SANTA ROSA - JOSE DOMINGO CHOQUEHUANCA

: CORPORACION INCA

: 19 DE ENERO DEL 2015

Caliacata
Muestra

: N 1

Profundidad (m)

: 2.70 mt

Clasificacion (SUCS)

: ML

:1

Calicata

Cohesion

Angulo

Muestra

(c)

Friccin

SUCS

Fact. de Capac.
de Carga

Ancho de

Densidad

Profund. de

Ciment.(B)

Natural

Ciment.(Df)
(m)

Interna ()

Nc

Nq

Nr

(m)

(gr/cc )

21.93

16.88

7.82

7.13

1.5

qu

q Adm.
F.S.( 3 )

(Tn/m2)

(Kg/cm2)

26.08

0.87

C-1
0.264

1.00

M-2
C-1

0.58
0.264

21.93

16.88

7.82

7.13

1.5

1.50

31.94

M-2
C-1
0.264

21.93

16.88

7.82

7.13

1.5

2.70

46.02

21.93

16.88

7.82

7.13

1.5

3.00

43.75

21.93

16.88

7.82

7.13

1.5

5.50

73.07

1.46
0.98

0.264

1.53
1.03

0.264

M-2
C-1
M-3
M-2

1.06
0.71

M-2
C-1

2.44
1.63

OBSERVACIONES: LAS MUESTRAS FUERON PUESTAS EN LABORATORIO POR EL SOLICITANTE

FN: 003537

Informe de compatibilidad para formatos de laboratorio.xls


Ejecutar el 21/12/2016 17:41
Las siguientes caractersticas de este libro no son compatibles con versiones
anteriores de Excel. Estas caractersticas podran perderse o degradarse si
abre el libro con una versin anterior de Excel o si lo guarda con un formato de
archivo anterior.
Prdida significativa de funcionalidad

Una o ms celdas de este libro contienen reglas de validacin de datos que


hacen referencia a valores en otras hojas de clculo. Estas reglas de
validacin de datos no se guardarn.

N de apariciones

GRANULOMETRIA BASE'!M82

GRANULOMETRIA BASE'!M18

Prdida menor de fidelidad


Algunas frmulas de este libro estn vinculadas a otros libros que estn
cerrados. Cuando estas frmulas se vuelven a calcular en versiones anteriores
de Excel sin abrir los libros vinculados, los caracteres que exceden el lmite de
255 caracteres no se pueden devolver.

8
Nombres definidos

Versin

Excel 97-2003

Excel 97-2003

También podría gustarte