Está en la página 1de 1

1

6
CLIENT

10

11

12

13

100800

17625

8400

8400

8400

50

415

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE

200

300

8400

500

A.2

CONSULTANT:
TUNNEL TO CENTRAL UTILITY
PLANT BUILDING (B04)
10100

9000

8400

MATCH LINE SEE DWG NO. 1257B03-S101a

8400

450

450

450

450

700

C3

700

C3

700

C3

1550

450

900

SUB CONSULTANT:

500

2500
500

450

C3
700

C3
700

19300

700

A.1

C3
700

C3

16200

Saudi Diyar Consultants

10300

50mm EXPANSION JOINT WITH


FILLER AND APPROVED
WATERSTOP

450
500

NOTES:

50mm EXPANSION JOINT WITH


FILLER AND APPROVED
WATERSTOP

400

1150

C1

CORE No. 05
& STAIR No. 08

2500

3000

300

1350

1575

400

400

300
300

CORE No. 10
& STAIR No. 07

1650

300

300

1350

5625

400

300

C1
400

C1

500 300

400

2150

300

C3

300

7800

300

8400

200

400

400

C1

2.

ALL DIMENSIONS & LEVELS ARE TO BE COORDINATED


WITH ARCHITECTURAL & CIVIL DRAWINGS.

3.

ALL DIMENSIONS ARE IN MILLIMETERS.

4.

IN CASE OF ANY DISCREPANCY BETWEEN STRUCTURAL


DRAWINGS & SITE CONDITIONS, REFER TO THE
CONSULTING ENGINEER.

5.

ALL PIPE SLEEVES & OTHER BUILDER'S WORK


REQUIREMENTS FOR ELECTRO-MECHANICAL WORKS,
SHALL BE COORDINATED WITH THE APPROVED
ELECTRO-MECHANICAL SHOP DRAWINGS BEFORE
CONCRETING.

6.

FOR COLUMNS, FOOTING DETAILS & SCHEDULES


REFER TO DRAWING NO. 1257B03-S701.

7.

ALL PERIMETER COLUMNS SHALL CONTINUE UP TO


PARAPET LEVEL, UNLESS OTHERWISE INDICATED.

8.

FOR SIZES & LOCATIONS OF SLAB OPENINGS,


TRENCHES & PITS REFER TO ELECTRO-MECH.
DRAWINGS.

9.

SOIL BEARING CAPACITY BELOW FOUNDATION SHALL

400

C1

400

400

C1

400

VERIFY THIS ASSUMPTION BEFORE STARTING


CONSTRUCTION . IN CASE OF ANY DISCREPANCY
BETWEEN THE DESIGN SOIL BEARING CAPACITY & SOIL
CONDITION REFER TO CONSULTING ENGINEER.

400

8400

400

C1

400

C1
400

400

C1
400

C1

FOR GENERAL NOTES, SEE DWG. NO. 1257B01-S001...

300

400

7800

400

300

1.

10. PLAIN CONCRETE USED IN BLINDING SHALL HAVE


MINIMUM 28 DAYS CYLINDER STRENGTH OF 200 Kg/

11. REINFORCING STEEL BARS SHALL BE DEFORMED HIGH


GRADE STEEL OF YIELD STRENGTH 4200 Kg/
(MIN.)
12. UNLESS OTHERWISE SPECIFIED. REINFORCED
CONCRETE SHALL HAVE A MIN. 28 DAYS CYLINDER .
STRENGTH OF 400 Kg/

200 500 100

400

400

400

400

C1

400

8000

400

C1
400

C1
400

C1
400

C1
400

400

C1
400

C1

400

7600

400

1550

500

8400

400

REVISED AS CLOUDED

05/17/2015

REVISED AS CLOUDED

02/03/2015

REV.NO.

DESCRIPTION

DATE

KEY PLAN
C1

12

400

C1
400

C1
400

C1
400

C1
400

400

C1
400

C1

A
400

400

400

400

400

400

8400

400

L
1257B03-S101d

400

400

400

400

400

AM

C1
400

C1
400

C1
400

C1
400

C1
400

400

C1
400

C1

PROJECT MANAGER

1257B03-S101d

YS

400
6400

300

MATCH LINE SEE DWG NO. 1257B03-S101a

250 300

SL

ELECTRICAL

400

ARCHITECT

STRUCTURAL
FA

MECHANICAL
MA

ICT
ZM

CIVIL/LS

DRAWN BY

CHECKED BY

AE/HF

HM

AR

PROJECT TITLE:

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE
Jeddah - Saudi Arabia

B03 KITCHEN & LAUNDRY


DRAWING TITLE:

METERS

EM

SCALE 1:100

AT

10

COLUMNS & AXES LAYOUT - PART c


1c PARTIAL
SCALE
1:100 M.

SC

IC

PARTIAL
COLUMNS & AXES LAYOUT
PART c
SCALE

DATE

CAD FILE

1:100

JUNE 2014

1257B03-S101

DRAWING NUMBER

1257B03-S101c

REVISION

2
Saudi Diyar Consultants

También podría gustarte