3.
What is the Cold Water Fixture Unit (CWFU) for the highlighted fixture?
10
4.
5.
(PP-2B) - (2)
6.
Gate
230
7.
Open Revit project ELEC_SYSTEM_M.rvt.
1. Make Coordination >All >Ceiling Plan>Level 1 Ceiling Plan Lighting in
cleaning Rm the active view.
1
r
What is the average estimated illumination for the Cleaning Room space in
lx? (also try 301 lx)
300.64
8.
Open Revit Project MECH_1.rvt Link the drawing file Floor Plan
Sample.dwg using the default settings.
What is the name of the layer for the element highlighted with a pointer as
shown?
E-B-FURR
9.
Open Revit project MECH_SYSTEM_M.rvt.
1. Make Plumbing> Plumbing>Waste & Vent> Floor Plans>1- Plumbing
the active view.
2. Place a 380 Liter Water Heater in Room Mech 11.
10.
P-1
11.
Open Revit Project ELECTRICAL . rvt.
1. Make Electrical > Power > Floor Plan> Level 1 Power Plan callout 1
the active view.
2. Place a standard duplex receptacle along the north wall of the
Electrical Room as highlighted with arrow.
3. Change the receptacle to a ground Fault receptacle.
12.
GFCI
1. Make Mechanical > HVAC> Floor Plans> 1- Mech the active view.
2. Use the Tag by category tool to tag the duct that is highlighted with the
arrow using the default tag settings.
432 x 381
13.
3. Duplicate the Air Pipe System from the Other Pipe System
4. Use the following settings:
Weight: 5
Color: Magenta
Abbreviation: A
Material: Carbon Steel
Description: Compressed Air
1200
What is the Invert Elevation of the main sanitary waste pipe at the end of the
line after the extension?
1044.9
What is the Width Factor Parameter Value of the Text Type> 0.8000
(0.800000)
Air Flow
CFM
What is the airflow L/s in the supply duct at the WHSP supply connector
(rounded up to nearest whole number) ?
20.
900
What is the gross area of the zones rounded upto the nearest square meter? 275
21.
22.
1.
2.
3.
4.
5.
228.6
23.
What is the Mechanical-Fliw pressure Drop Parameter value of one of the new air
terminals?
14.00
24.
1. Make Mechanical> HVAC >Floor Plans > 1 Mech the active view.
2. Create a callout view of the MEN AND WOMENs TOILETS RMS. 24 AND 25.
25.
1:50
What is the dimension from the wall face to the side of the mechanicl equipment?
1450
26.
phase connection)
1. Make Electrical>Lighting>Floor Plans> level 2> Lighting Plan Staff Room
the active view.
2. Create lighting circuit including all 8 lights and the occupancy sensor switch.
XHHW
27.
1.
241.3
What is the location line parameter for the wall that is highlighted with a
pointer as shown?
Wall Centerline
29.
30.
PP-4A
.
What is the switch load classification?
Lighting
31.
32.
What is the labeled dimension from the base flashing to the House Clamp on the
Vent Thru Roof detail (the dimension highlighted by the arrow)?
203mm
Minimum
33. Open Revit Mechanical project MECH_3.rvt (note: this project will open
in imperial units).
Copy/Monitor the linked file using the following settings.
Under categories and Types to copy:
Is the identify data parameter for AR- Level2 set to Structural or Building Story?
Enter the name of the value that is checked.
Building Story
34.
1. Make Plumbing >HVAC > Floor Plans> 1 Mech the active view.
2. Convert the Placeholder Duct System in space 35 to a Supply Air Duct
system
3. Utilise the rectangular duct system with Mitered Elbow/Taps to make
the conversion
4. Split the main duct following the first and second branches. The final
conversion should look similar to the illustration
5. Size the duct system using the following settings:
Equal Friction 0.82pa/m
Branch sizing- Calculated Size only
.
.
What is the size of the first main supply duct segment downstream of the
WSHP Unit
406.4 x
406.4
35.
1. Make Electrical> HVAC > Floor Plans> HV-Level 1 the active view.
2. Place a water source Heat Pump Unit in the open space as shown by
the highlight arrow.
Answer
1: 1
22
10
ALL
(PP-2B) (2)
230
300.64
E-B-FURR
32.0
P-1
GFCI
432 x 381
648
Volume only
Architectural
1200
1044.9
0.8000
900
275
228.6
3
14.00
1 : 50
1390
XHHW
241.3
Wall Centerline
PP-4A
Lighting
4
203mm Minimum
Building Story
34
35
406.4 x 406.4