CARACTERISTICAS DE PARARRAYOS

Tension
Nominal
Arrester Rating
(kV-rms)
3.0
6.0
9.0
10.0
12.0
15.0
18.0
21.0
24.0
27.0
30.0
36.0

Tens. Max.
Operacin
MCOV
(kV-rms)
2.6
5.1
7.7
8.4
10.2
12.7
15.3
17.0
19.5
22.0
24.4
29.0

Sobretension
con onda
1,2/50 ms
kV-Crest
11.0
22.0
33.0
36.3
44.0
55.0
66.0
77.0
86.6
97.9
108.9
128.3

Tensin residual para onda de 10 kA, 8/20 ms


1,5 KA
8.2
16.4
24.5
27.0
32.7
40.9
49.1
57.3
64.4
72.8
81.0
95.4

3,0 KA
8.7
17.4
26.1
28.7
34.7
43.4
52.1
60.8
68.4
77.3
86.0
101.3

Fuente : Datos obtenidos de pararrayos Tipo AZL de McGraw-Edison

5 kA
9.2
18.4
27.5
30.3
36.7
45.9
55.1
64.3
72.3
81.7
90.9
107.0

10 kA
10.0
20.0
25.0
33.0
40.0
50.0
60.0
70.0
78.8
89.0
99.0
116.6

20 KA
11.3
22.5
33.8
37.2
45.0
56.3
67.6
78.8
88.7
100.2
115.5
131.3

40 KA
13.6
27.1
40.7
44.7
54.2
67.8
81.4
94.9
106.8
120.7
134.2
158.1

Sobretensiones de
Maniobra
KV
7.4
14.7
22.1
24.3
29.4
36.8
44.1
51.5
57.9
65.5
72.8
85.8

SELECCIN DE PARARRAYOS

CALCULO DEL PARARRAYOS PARA UN SISTEMA EN 22.9 KV


VALOR
22.9
25.0
AISLADO
1.05

TENSION NOMINAL DEL SISTEMA = Vn (kV)


TENSION MAXIMA DEL SISTEMA (entre fases) = Us (kV r.m.s).
TENSION MAXIMA DE LOS EQUIPOS = Um (kV r.m.s).
FACTOR DE MAYOR VARIACION DE TENSION = Ft (pu).
FACTOR DE FALLA A TIERRA PARA UN SISTEMA CON NEUTRO RIGIDO A TIERRA (04 HILOS) = K (pu)

1.4

FACTOR DE FALLA A TIERRA PARA UN SISTEMA NEUTRO AISLADO (03 HILOS) = K (pu)
MAXIMA DURACION DE LA SOBRETENSION TEMPORARIA = t (seg).
FACTOR DE SOBRETENSION TEMPORAL PARA UNA FALLA DE 10 Seg. = Ktov
10 kA/Ur (valores que dependen del fabricante)

1.73
10
1.075

ALTITUD DE INSTALACION (m.sn.m.)


NIVEL DE AISLAMIENTO DEL EQUIPAMIENTO = BIL (kVp)
NIVEL DE CONTAMINACION (mm/kV).
CORRIENTE NOMINAL DE DESCARGA REQUERIDA = In (kA).
DIAMETRO DEL RESITOR DE OM APROPIADO PARA In = 10 kA (mm) .
MAXIMA CORRIENTE DE CORTOCIRCUITO = In (kA).

2600
125
25
10.00
40.00
20.00

2.667

CALCULO DEL MCOV


DESCRIPCION

VALOR

TENSION MAXIMA DE OPERACIN PERMANENTE MINIMA REQUERIDA PARA UN SISTEMA CON NEUTRO

RIGIDO A TIERRA = MCOV (kV ef) = Uc min


TENSION MAXIMA DE OPERACIN PERMANENTE MINIMA REQUERIDA PARA UN SISTEMA CON NEUTRO

AISLADO = MCOV (kV ef) = Uc min

15.16
25.00

CALCULO DE LA TENSION NOMINAL DEL PARARRAYOS (Ur)


DESCRIPCION

VALOR

TENSION NOMINAL DEL PARARRAYOS PARA UN SISTEMA CON NEUTRO RIGIDO A TIERRA = Ur1,min (kV ef)

18.94

TENSION NOMINAL DEL PARARRAYOS PARA UN SISTEMA CON NEUTRO RIGIDO A TIERRA = Ur2,min (kV ef)

18.80

TENSION NOMINAL DEL PARARRAYOS PARA UN SISTEMA AISLADO = Ur1, min (kV ef)

31.25

TENSION NOMINAL DEL PARARRAYOS SELECCIONADA PARA UN SISTEMA CON NEUTRO RIGIDO A

TIERRA = Ur = mx {Ur1, Ur2} redondeada al numero inmediato superior divisible por tres.
TENSION NOMINAL DEL PARARRAYOS SELECCIONADA PARA UN SISTEMA AISLADO = Ur = mx {Ur1, Ur2}
redondeada al numero inmediato superior divisible por tres.
TENSION MAXIMA DE OPERACIN PERMANENTE REDEFINIDA PARA UN SISTEMA CON NEUTRO RIGIDO A
TIERRA = MCOV (kV ef) = Uc
TENSION MAXIMA DE OPERACIN PERMANENTE REDEFINIDA PARA UN SISTEMA AISLADO = MCOV (kV ef)
= Uc

30.00
31.25
24.00
25.00

SOBRETENSIONES TEMPORARIAS PARA UN SISTEMA CON NEUTRO RIGIDO A TIERRA = UTOVP (kV)

20.21

SOBRETENSIONES TEMPORARIAS PARA UN SISTEMA AISLADO = UTOVP (kV)

20.21

SELECCIN DE LA CLASE DE DESCARGA DE LINEAS


(LA EXIGENCIA DE LOS DESCARGADORES AUMENTA AL IR DE LA CLASE UNO A LA CINCO)
DESCRIPCION

VALOR

NIVEL DE PROTECCION AL IMPULSO ATMOSFERICO (10 kA,

8/20 us

NIVEL DE PROTECCION AL IMPULSO DE MANIOBRA (0,5 kA,

30/60 us

NIVEL DE PROTECCION AL IMPULSO ESCARPADO DE CORRIENTE ( 10 kA,


NIVEL BASICO DE AISLAMIENTO (BIL/10 kA,
DISTANCIA DISRUPTIVA (mm).
DISTANCIA DISRUPTIVA (mm).

8/20 us

80.01
80.00

)
1/2 us

85.00
1.56
625.00
625.00