PURPOSE
The Immunohaematology Laboratory (IHL) separates Whole Blood into components
to maximize its usage.
EQUIPMENT
Tube sealer
Laminar flow
Refrigerated centrifuge
Plasma expresser
Double pan weighing balance
SUPPLIES
Triple bags
Manuals of all equipment for reference regarding use and maintenance of each
equipment
SPECIAL SAFETY PRECAUTIONS
Follow universal precautions when working in a laboratory environment with
potentially infectious agents.
PROCEDURE
Preliminary Statement
It is the responsibility of the component room technician to separate
components from whole blood collected in multiple bags. The packed cells
unit should be within the range of 235-350mls, Fresh Frozen Plasma 200260mls, Platelets and Cryoprecipitate 60-80mls.
Preparation of Red Blood Cells (RBC) and Fresh Frozen Plasma(FFP)
1. Turn centrifuge on and ensure it is set to 4C
2. Remove whole blood from 2-8C unclear storage area or donor area.
Process all whole blood units within 6hrs of collection.
3. Resuspend all whole blood units before placing into centrifuge cups,
massage blood out of blood bag ports.
4. Place whole blood bags on cups, balance centrifuge cups two at a time
using balance scale.
5. Repeat with remaining bags and close centrifuge lid.
6. Enter Program 3 on centrifuges (7mins at 4200RPM) press enter.
7. Remove whole blood bags gently from centrifuge cup.
8. Place blood bag on plasma expresser and release spring clamp on
expresser.
9. Break the seal of the tube connecting to the satellite bag.
10. Express plasma into satellite bag, leaving 50-60mls of plasma on red
blood cells.
11. Seal plasma tubing and red cell tubing. Separate after ensuring unit
number is on both bags.