AC Power Systems

For Business-Critical Continuity

Liebert MicroPOD
Wrap-Around Maintenance Bypass With Output Distribution

When a computer system cannot be without power even for maintenance

Key Benefits:

a Liebert MicroPOD ensures continuous uptime. The Liebert MicroPOD

Higher Availability

provides maintenance bypass capability and power output distribution for

Provides utility power to attached


equipment when switched to
maintenance bypass mode.

Allows UPS maintenance or


replacement of the UPS without
discontinuing power to critical
equipment.

Liebert GXT and Liebert PSI UPS models 3 kVA and below, as well as other
brands of UPS systems. It allows removal of the UPS without powering down
the connected equipment.
The Liebert MicroPOD maintenance bypass and power output
distribution switch allows you to manually transfer the connected

Flexibility

equipment to utility power via a maintenance bypass switch,

Easily installed the UPS and utility


power are both connected to the
MicroPOD with the supplied cords.

Allows scheduled UPS maintenance


to ensure continuous uptime without
having to shut down protected
equipment.

Rotary switch with indicators make


the unit simple to operate.

Plug-and-play connectability for both


input and output.

Compatible with any brand of UPS


system.

permitting scheduled maintenance or UPS replacement without


discontinuing power to the critical load. Transferring back to UPS
power is just as easy simply turn the switch to the indicated
position and the load is protected by the UPS. Available in plug-andplay or hardwired options at 120V or 208V rating, units include
brackets for rack mounting in any direction.

Lowest Total Cost Of Ownership

UL c UL

Assures system uptime during


maintenance activities.

Extreme affordability.

Two-year, no-hassle replacement


warranty eliminates the cost of
replacement during the warranty
period.

Liebert Corporation

MicroPOD Specifications
Part Number
MP2-115A
MP2-120C
MP2-130C
MP2-130E
MP2-130P
MP2-115HW
MP2-120HW
MP2-130HW

Receptacle to
UPS Input

Plug to Utility

Plug to
UPS Output

MicroPOD
Output Receptacles

120V UL Listed MicroPODs


5-15R
5-15P
5-20R
5-20P
L5-30R
L5-30P
L5-30R
L5-30P

5-15P
5-20P
L5-30P
L5-30P
L5-30P
Hardwired
Hardwired
Hardwired

L5-30R
5-15R
5-20R
5-30R

(8)5-15R
(8)5-20R (T-Slot)
(8)5-20R (T-Slot)
(2)5-15R, (4) 5-20R (T-Slot)
(1) L5-30R
(4) 5-15R, (2) L5-20R
Hardwired
Hardwired
Hardwired

L5-30P
5-15P
5-20P
5-30P

1050 Dearborn Drive


P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX

208V UL Listed MicroPOD

MP2-220N

MP2-210K
MP2-220L

L6-20P OR
Hardwire Connection
(plug is removable for
hardwire applications)

L6-20R

(2) L6-20R, (2) L6-15R,


OR Hardwire Connections
(receptacles are removable
for hardwire applications)

L6-20P

230V CE Marked MicroPODs


EN60320/C13
EN60320/C14
EN60320/C19
EN60320/C20

EN60320/C14
EN60320/C20

(4) EN60320/C13
(4) EN60320/C13, (1)EN60320/C19

Emerson Network Power Asia Pacific


7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX

liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)

Protected
Devices

Configuration
The MicroPOD plugs into the utility
and UPS, and the UPS is plugged
into the MicroPOD. All protected
devices are connected to the
MicroPOD, allowing maintenance
bypass for the UPS.

While every precaution has been taken to ensure accuracy and


completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
2007 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-23800 (R02/07)

15
A
M
P

PUSH TO RESET

UPS

UPS
AVAILABLE

UPS

MAINTENANCE BYPASS
AVAILABLE

UTILITY

15
A
M
P

PUSH TO RESET

UTILITY

OUTPUT

OUTPUT

CAUTION
IF UTILITY LAMP IS ILLUMINATED
MAINTENANCE BYPASS POSITION
MAY BE SELECTED
SWITCH TO UPS POSITION ONLY
WHEN UPS LAMP IS ILLUMINATED

Emerson Network Power.


The global leader in enabling
Business-Critical Continuity.

CONNECT UPS
LINE CORD HERE

From Utility
MicroPOD
plugs into
UPS outlet

Printed in USA

UPS plugs into


MicroPOD

AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.com
Business-Critical Continuity, Emerson Network
Power and the Emerson Network Power logo
are trademarks and service marks of Emerson
Electric Co. 2007 Emerson Electric Co.

También podría gustarte