Está en la página 1de 4

Datos de campo

AB/2 (m)

MN/2 (m)

1.00
1.30
1.60
2.00
2.50
3.20
4.00
5.00

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
1
0.32
1
1
1
1
1
3.2
1
3.2
3.2
3.2
3.2
3.2
10
3.2
10
10
10
10

6.30
8.00
10.00
13.00
16.00
20.00
25.00
32.00
40.00
50.00
63.00
80.00
100.00
130.00

P med
(m)
19.930
12.970
11.410
10.760
10.590
11.070
11.160
12.210
11.070
12.390
14.630
17.280
19.310
19.190
21.060
20.070
21.880
21.250

V/I ()

I (mA)

error

4.523
1.66
945.8
562.2
350.9
222.5
143
96.97
296.1
62.81
182.2
125.2
94.06
65.49
48.22
159.1
33.6
109.6

2
100
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200

0.01
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2

30.290
34.590
38.570
37.840
43.530
43.400
47.480
49.640
47.650

0.6086
0.0443
0.0316
0.1004
0.0205
0.0714
0.0480
0.0319
0.0181

200
200
200
200
200
200
200
200
200

0.1
0.1
0.2
0.2
0.0
0.5
0.1
0.1
0.5

En IPI2WIN se abre un nuevo file y se cargan AB/2, MN y resistividad


aparente

Aqu se muestran los datos de resistividad aparentes medidos en campo


una vez cargados en el software.

Perfil del sondeo elctrico vertical

Una vez cargados los datos, se aproxima la curva roja a la curva de los
datos reales y la ventana emergente aparecern los datos de espesores,
resistividades y profundidades.

*curva hecha en ip2win


Se cargan los datos en new file y posteriormente se hace el ajuste de la curva,
el software nos regresas resistividades calculadas y la curva ideal.

Curva teorica

Resultados

N
Capa 1
Capa 2
Capa 3

Resistividad
(Ohm-m)
28.5
9.37
57.6

Espesor (m)

Profundidad (m)

0.427
4.17

0.427
4.6

También podría gustarte