Está en la página 1de 412

TOLL FREE 1.800.342.7215 | 1.954.455.3050 | sales@buyawg.com | www.buyawg.

com

YOUR SINGLE SOURCE FOR WIRE AND CABLE PRODUCTS

GROUNDING CABLES/
STATIC & GUY WIRE

TRANSMISSION &
DISTRIBUTION CABLES

MULTIPLEX
CABLES

LOW VOLTAGE
CABLES

MEDIUM VOLTAGE
CABLES

ARMORED
CABLES

POWERFUL & ECONOMICAL WIRE & CABLE SOLUTIONS FOR...


WINDPOWER APPLICATIONS
TRANSMISSION & DISTRIBUTION

CONTROL
CABLES

OPGW/FIBER
OPTIC CABLES

PORTABLE POWER
CABLES

SOLAR APPLICATIONS

AMERICAN WIRE GROUP


WIRE & CABLES
Table of Contents
Grounding Cables/Static Wire/Guy Wire .............................................................................100
Transmission & Distribution Cables.....................................................................................400
Multiplex Cables ..................................................................................................................1000
Low Voltage Cables ...............................................................................................................200
Medium Voltage Cables ........................................................................................................300
Armored Cables .....................................................................................................................900
Control Cables .......................................................................................................................500
OPGW/Fiber Optic Cables ....................................................................................................600
Portable Power Cables ..........................................................................................................700
Appendix ................................................................................................................................800

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

0
20140921

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Grounding Cables
Bare Copper ........................................................................................................................101
Tinned Copper ....................................................................................................................102
Trolley Wire Copper............................................................................................................103
Copperclad Steel Wire........................................................................................................104
Tracer Wire Polyethylene Insulated Copperclad Steel ....................................................109
Static & Guy Wire
Alumoclad Steel Wire.........................................................................................................105
Type M Alumoclad Steel Wire Guy Strand ......................................................................106
Galvanized Guy Wire/Static Wire.......................................................................................107

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

100
201400921

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

GROUNDING, STATIC & GUY WIRE


Table of Contents

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Applications
Used for overhead electrical distribution lines, grounding electrical substations, electrical test
equipment and any other electrical system. Suitable for numerous other applications.
Specifications
ASTM Specifications, latest issue, as follows:
Solid
ASTM B-1 Hard Drawn Temper
ASTM B-2 Medium Hard Drawn Temper
ASTM B-3 Soft Drawn Temper
Stranded
ASTM B-1 Hard Drawn Temper
ASTM B-2 Medium Hard Drawn Temper
ASTM B-3 Soft Drawn Temper
ASTM B-8 - Concentric Lay, All Tempers
Notes
Ampacities (Amps per Conductor) are based on a 30C ambient temperature, single conductor in
air, per NEC.

Item #

SCC-01
SCC-02
SCC-03
SCC-04
SCC-05
SCC-06
SCC-07
STC-01
STC-02
STC-03
STC-04
STC-05
STC-06
STC-06a
STC-07
STC-07a
STC-08
STC-08a
STC-09
STC-09a
STC-10
STC-11
STC-12
STC-14
STC-15
STC-16
STC-17

Size
AWG
or KCMIL

Number
of Strands

Overall
Diameter
(in)

Weight
/MFT
(lb)

Allowable
Amps per
Conductor

Breaking
Strength
Soft
(lb)

Breaking
Strength
Medium
(lb)

Breaking
Strength
Hard
(lb)

14
12
10
8
6
4
2
8
6
4
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
300
350
500
600
750
1000

Solid
Solid
Solid
Solid
Solid
Solid
Solid
7
7
7
7
7
7
19
7
19
7
19
7
19
19
37
37
37
61
61
61

0.064
0.081
0.102
0.129
0.162
0.204
0.258
0.146
0.184
0.232
0.292
0.332
0.373
0.373
0.419
0.419
0.470
0.470
0.528
0.528
0.575
0.630
0.681
0.813
0.893
0.998
1.152

12.43
19.77
31.43
49.98
79.46
126.40
200.90
51.0
81.1
128.9
204.9
258.4
325.8
325.8
410.9
410.9
518.1
518.1
653.3
653.3
771.9
926.3
1081.0
1544.0
1853.0
2316.0
3088.0

32
41
68
95
125
170
225
95
130
170
230
265
310
310
355
355
410
410
480
480
530
590
650
810
910
1040
1240

124.2
197.5
314
479.8
762.9
1213
1928
499
794
1320
2110
2552
3221
3221
4062
4062
5074
5074
6453
6453
7940
9160
10580
15240
18300
22890
30500

166.6
261.2
410.4
643.9
1010
1584
2450
610
959
1505
2360
2995
3705
3705
4640
4640
5970
5970
7479
7479
8952
10530
12450
17550
21060
26510
35100

213.5
336.9
529.2
826
1280
1970
3002
777
1228
1938
3050
3801
4752
4752
5926
5926
7698
7698
9617
9617
11600
13510
16060
22510
27020
34090
45030

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

101
20140110

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Bare Copper

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Applications
Used for overhead electrical distribution lines, grounding electrical substations, electrical test
equipment and any other electrical system. Suitable for numerous other applications.
Specifications
ASTM Specifications, latest issue, as follows:
Solid
ASTM B-3 Soft Drawn Temper
ASTM B-33 Tinned, Soft or Annealed Copper Wire
Stranded
ASTM B-8 Concentric Lay, All Tempers Tinned
ASTM B-33 Tinned, Soft or Annealed Copper Wire
Notes
Ampacities (Amps per Cond.) are based on a 30C ambient temperature, single conductor in air, per
NEC.

Item #

SCC-T-01
SCC-T-02
SCC-T-03
SCC-T-04
SCC-T-05
SCC-T-06
SCC-T-07
STCC-T-01
STCC-T-02
STCC-T-03
STCC-T-04
STCC-T-05
STCC-T-06
STCC-T-06a
STCC-T-07
STCC-T-07a
STCC-T-08
STCC-T-08a
STCC-T-09
STCC-T-09a
STCC-T-10
STCC-T-11
STCC-T-12
STCC-T-14
STCC-T-15
STCC-T-16
STCC-T-17

Size
AWG
or KCMIL

Number
of Strands

Overall
Diameter
(in)

Weight
/MFT
(lb)

Allowable
Amps per
Conductor

Breaking
Strength
Soft
(lb)

Breaking
Strength
Medium
(lb)

Breaking
Strength
Hard
(lb)

14
12
10
8
6
4
2
8
6
4
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
300
350
500
600
750
1000

Solid
Solid
Solid
Solid
Solid
Solid
Solid
7
7
7
7
7
7
19
7
19
7
19
7
19
19
37
37
37
61
61
61

0.064
0.081
0.102
0.129
0.162
0.204
0.258
0.146
0.184
0.232
0.292
0.332
0.373
0.373
0.419
0.419
0.470
0.470
0.528
0.528
0.575
0.630
0.681
0.813
0.893
0.998
1.152

12.43
19.77
31.43
49.98
79.46
126.4
200.9
51.0
81.1
128.9
204.9
258.4
325.8
325.8
410.9
410.9
518.1
518.1
653.3
653.3
771.9
926.3
1081.0
1544.0
1853.0
2316.0
3088.0

32
41
68
95
125
170
225
95
130
170
230
265
310
310
355
355
410
410
480
480
530
590
650
810
910
1040
1240

124.2
197.5
314
479.8
762.9
1213
1928
499
794
1320
2110
2552
3221
3221
4024
4024
5118
5074
6459
6453
7627
9160
10580
15240
18300
22890
30500

166.6
261.2
410.4
643.9
1010
1584
2450
610
959
1505
2360
2955
3705
3705
4765
4765
5812
5970
7278
7479
8836
10530
12450
17550
21060
26510
35100

213.5
336.9
529.2
826
1280
1970
3002
777
1228
1938
3050
3801
4752
4752
5926
6690
7366
7698
9154
9617
11360
13510
16060
22510
27020
34090
45030

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

102
20140110

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Tinned Copper

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Applications
Trolley wire is used as an overhead power source for electric railroad locomotives, cranes, light rail
transit systems, and underground mining motor cars.
Construction
Single conductor, solid copper, having a hard drawn temper, made in the configurations of: round,
grooved, figure 8 or figure 9 deep section. Special alloys available.
Specifications
ASTM B-47

Item #

Nominal
Conductor
Size

Round
R 1/0
1/0 AWG
R 2/0
2/0 AWG
R 3/0
3/0 AWG
R 4/0
4/0 AWG
R 300 300 MCM
Grooved
G 2/0
2/0 AWG
G 3/0
3/0 AWG
G 4/0
4/0 AWG
G 300 300 MCM
G 350 350 MCM
Figure 8
F8 1/0 1/0 AWG
F8 2/0 2/0 AWG
F8 4/0 4/0 AWG
F8 300 300 MCM
Deep Section
F9 350 350 MCM
F9 400 400 MCM

Overall
Diameter
(in)

Overall
Diameter
(mm)

Area
Circular

Area
(in2)

Area
(mm2)

Weight
/MFT
(lb)

Weight
/mile
(lb)

Weight Tensile Tensile Resist.


/km
Strength Strength (68(kg)
(lb/in2) (kg/mm2) 20C)
/MFT
(ohm)

Resist.
(6820C)
/mile
(ohm)

Resist.
(6820C)
/km
(ohm)

Min.
Min.
Break. Break.
Strength Strength
(lb)
(kg)

.3249
.3648
.4096
.4600
.5477

8.252
9.266
10.404
11.684
13.911

105600
133100
167800
211600
30000

.0829
.1045
.1318
.1622
.2356

53.5
67.4
85.0
107.2
152.0

319.5
402.8
507.8
640.5
908.0

1687
2127
2681
3382
4794

475
599
755
953
1350

54.5
52.8
51.0
49.0
46.4

38.3
37.1
35.9
34.5
32.6

.1011
.08021
.06362
.05405
.03558

.53381
.42351
.33591
.26638
.18786

.33177
.26321
.20877
.16556
.11676

4518
5519
672
8143
10930

2049
2503
3048
3694
4958

.392
.430
.482
.574
.620

9.956
10.922
12.243
14.580
15.748

137900
167300
212000
299800
351200

.1083
.1314
.1665
.2355
.2758

69.9
84.8
107.4
151.9
177.9

417.4
506.4
641.7
907.5
1063.0

2204
2674
3388
4792
5613

621
753
955
1350
1582

50.2
48.5
46.6
44.2
42.8

35.3
34.1
32.8
31.1
30.1

.07741
.06380
.05035
.03560
.03039

.40872
.33686
.26585
.18797
.16046

.25402
.20936
.16523
.11682
.09973

5437
6373
7759
1041
11810

2466
2891
3519
4722
5357

.420x.312
.480x.352
.600x.450
.754x.570

10.7x7.9
12.2x8.9
15.2x11.1
19.2x14.5

105600
133100
211600
350100

.0829
.1045
.1662
.2750

53.5
67.4
107.2
177.4

319.7
402.9
640.5
1060.0

1687
2127
3382
5595

475
599
953
1577

51.8
50.2
46.6
42.8

36.4
35.3
32.8
30.1

.1011
.08020
.05045
.03049

.53381 .33177
.42346 .26318
.26638 .16556
.16099 .10001

4296
5248
7744
11700

1949
238
3513
5339

.707x.496 17.9x12.6 348900


.715x.522 18.9x14.0 397200

.2740
.3120

176.8
201.3

1056.0
1202.0

5576
6348

1571
1789

42.8
41.3

30.1
29.0

.03059
.02687

.16152
.14187

11730
12880

5321
5842

.10039
.08817

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

103
20140110

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Trolley Wire
Copper

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Applications
Copperclad steel wire and strand combines the electrical characteristics of copper with the mechanical properties of steel. Often used for buried ground grid systems, overhead ground wire and messenger wire, it can resist mechanical damage during installation, as well as electrical damage
during a fault condition.
Copperclad steel has virtually no scrap value, greatly reducing the potential of theft.
Construction
Dead Soft Annealed (DSA) Copperclad Steel (CCS) conductors are a concentric lay-stranded construction. The CCS strands are a 40% conductivity grade of material using a low carbon steel core
rendering greater flexibility to enable easier handling during installation
Specifications
CCS bare conductors meet or exceed the following ASTM specifications:
B-193 Standard Test Method for Resistivity of Electrical Conductor Materials
B-227 Standard Specification for Hard-Drawn Copperclad Steel Wire
B-228 Standard Specification for Concentric-Lay-Stranded Copperclad Steel Conductors
B-258 Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG
Sizes of Solid Round
B-910 Standard Specification for Annealed Copperclad Steel Wire
Wires Used as Electrical Conductors
Note
The ampacity rating and the DC and AC resistance of the Copperclad Steel wire conductor is not
equivalent to that of copper conductor.
To select the correct equivalent please see Diameter Comparison for Copper Equivalent Fusing
Current for Grounding Applications.
Diameter Comparison for Copper Equivalent
Fusing Current for Grounding Applications
Description
Bare Copper
Size
Substitute of
7#5
7#6
7#7
7#8
7#9
19#5
19#6
19#7
19#8
19#9
19#0.105

3/0
2/0
1/0
1 AWG
2 AWG
500 MCM
400 MCM
300 MCM
250 MCM
4/0
4/0

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

104
20160411

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Copperclad
Steel Wire

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Copperclad
Steel Wire
Item #

Size

Size
Designation

Nominal
CrossSectional
Area
(c)

Nominal
CrossSectional
Area
(mm2)

Number
of
Wires

Diameter
of
Wires

Nominal
Overall
Diameter
(in)

Maximum
Resistance
DC@20C
Ohm
(M/ft)

Minimum
Breaking
Strength
(lb)

Nominal
Weight
(lb/ft)

7#9
7#8
7#7
7#6
7#5
19#9
19#8
19#7
19#6
19#5

7#9
7#8
7#7
7#6
7#5
19#9
19#8
19#7
19#6
19#5

11/32"
3/8"
7/16"
1/2"
9/16"
9/16"
21/32"
23/32"
13/16"
7/8"

0.07195
0.09078
0.1145
0.1443
0.1819
0.1953
0.2464
0.3107
0.3916
0.4938

46.42
58.57
73.86
93.09
117.40
126.00
159.00
200.50
252.70
318.50

7
7
7
7
7
19
19
19
19
19

0.1144
0.1285
0.1443
0.162
0.1819
0.1144
0.1285
0.1443
0.162
0.1819

0.343
0.385
0.433
0.486
0.546
0.572
0.642
0.721
0.81
0.91

0.2916
0.2311
0.1833
0.1454
0.1153
0.1079
0.0855
0.0678
0.0527
0.0418

2650
3350
4220
5320
6710
6820
8610
10850
13680
17250

0.259
0.327
0.413
0.52
0.656
0.707
0.892
1.125
1.418
1.787

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
104
20160411

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc. Hallandale, Florida

APPROXIMATE SHORT-TIME FUSING CURRENTS


Duration of Current in Cycles or Seconds
Conductor
Size AWG

3 cycles
(.05 sec)

6 cycles
(.10 sec)

9 cycles
(.15 sec)

30 cycles
(.5 sec)

60 cycles
(1.0 sec)

120 cycles
(2.0 sec)

Current in Amperes
40% Conductivity
7-Wire Strand
7 No. 4
7 No. 5
7 No. 6
7 No. 7
7 No. 8
7 No. 9
7 No. 10
19-Wire Strand
19 No. 5
19 No. 6
19 No. 7
19 No. 8
19 No. 9
Solid Wire
No. 2 Wire
No. 4 Wire
No. 6 Wire

7-Wire Strand
7 No. 4
7 No. 5
7 No. 6
7 No. 7
7 No. 8
7 No. 9
7 No. 10
19-Wire Strand
19 No. 5
19 No. 6
19 No. 7
19 No. 8
19 No. 9
Solid Wire
No. 2 Wire
No. 4 Wire
No. 6 Wire

154,000
122,000
97,000
77,000
61,000
48,000
38,000

109,000
86,000
68,000
54,000
43,000
34,000
27,000

89,000
70,000
56,000
44,000
35,000
28,000
22,000

49,000
38,000
31,000
24,200
19,000
15,000
12,000

34,000
27,000
22,000
17,000
14,000
11,000
8,500

24,000
19,000
15,000
12,000
10,000
7,600
6,000

330,000
262,000
208,000
165,000
131,000

234,000
185,000
147,000
117,000
92,000

191,000
151,000
120,000
95,000
74,000

104,000
83,000
66,000
52,000
41,000

74,000
59,000
46,000
37,000
29,000

52,000
41,000
33,000
26,000
21,000

35,000
22,000
14,000

25,000
16,000
9,800

11,000
6,900
4,400

7,800
4,900
3,100

5,500
3,500
2,200

137,000
108,000
86,000
68,000
54,000
43,000
34,000

97,000
77,000
61,000
48,000
38,000
30,000
24,000

79,000
63,000
50,000
39,000
31,000
25,000
20,000

43,000
34,000
27,000
22,000
17,000
14,000
11.000

31,000
24,000
19,000
15,000
12,000
9,600
7,600

22,000
17,000
14,000
11,000
9,000
6,800
5,400

294,000
233,000
185,000
147,000
116,000

208,000
165,000
131,000
104,000
82,000

170,000
135,000
107,000
85,000
67,000

93,000
74,000
58,000
46,000
37,000

66,000
52,000
41,000
33,000
26,000

47,000
37,000
29,000
23,000
18,000

31,000
20,000
12,000

22,000
14,000
9,000

18,000
11,000
7,100

9,800
6,200
3,900

6,900
4,400
2,700

4,900
3,100
1,900

20,000
13,000
8,000
Current in Amperes
30% Conductivity

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

104
20140926

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Copperclad
Steel Wire

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Description
HMW polyethylene covered copperclad wire.
Application
Telephone and signal lines, alarm circuits, remote control, tree wire, and grounding wire.
Standards
ASTM-B228

Item#

PCSC-6-30
PCSC-8-30
PCSC-9-30
PCSC-10-30
PCSC-6-40
PCSC-8-40
PCSC-9-40
PCSC-10-40
PCSC-12-40

Conductor
Type
(High Strength
Conductivity)
30%
30%
30%
30%
40%
40%
40%
40%
40%

Size
AWG

Wire
Diameter
(in)

Breaking
Strength
(lb)

6
8
9
10
6
8
9
10
12

.1620
.1285
.1144
.1019
.1620
.1285
.1144
.1019
.08081

2680
1815
1491
1231
2433
1660
1368
1130
785

DC
Resistance
ohms/MFT
@68
1343
2136
2693
3396
1.008
1.602
2.020
2.547
4.051

Covering
Thickness
(in)

Appox OD
PE Covered
(in)

Weight
/MFT
(lb)

Weight
/Mile
(lb)

2/64
2/64
2/64
2/64
2/64
2/64
2/64
2/64
2/64

.225
.191
.177
.164
.225
.191
.177
.164
.143

80.3
51.8
41.7
33.9
80.3
51.8
41.7
33.9
22.3

424
274
220
179
424
274
220
179
118

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

109
20140921

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Tracer Wire Polyethelene Insulated


Copperclad Steel

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Application
Overhead ground wire, shield wire protecting transmission lines against lightning damage.
Construction
Alumoclad steel wire and strand is used by power utilities as well as formed wire and optical
ground wire manufacturers. alumoclad steel wire outlasts other options by as much as 200% in corrosive environments, significantly lowering maintenance and replacement costs. When compared
to solid aluminum wire, alumoclad steel wire offers tremendous savings.
Alumoclad steel wire overhead ground wire has excellent corrosion resistance. Its strength and conductivity remain unchanged in any atmosphere where aluminum is satisfactory, especially those
known to be corrosive from industrial or atmospheric conditions.
This assurance against corrosion is obtained through the application of a thick covering of pure aluminum which provides a substantial barrier of protective metal. The minimum cladding thickness of
alumoclad steel wire is 10% of the radius of the wire. the cladding has a continuous, strong metallic
bond to the steel core that will not crack or flake.
Alumoclad steel wire also provides strength greater than or equal to other overhead ground wires.
For commonly used wire sizes, the tensile strength of the individual wire can approach 200,000
pounds per square inch. When used in a strand for overhead ground wire, this high strength permits greater span lengths, less sag and heavier loads under storm loading conditions.
Directly related to strength and sag performance is the lighter weight of alumoclad steel wire. Due
to its thick cladding of aluminum, alumoclad steel wire is 15% lighter that a steel strand of equivalent size. This lighter weight, combined with high strength, permits alumoclad steel wire to be installed to the same sags as steel with correspondingly lower tensions and tower stresses on the
towers or supporting structures.
Specifications
B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire
B416 Standard Specification for Concentric-Lay-Stranded Aluminum-Clad Steel Conductors

Item #

ALUM-01
ALUM-02
ALUM-03
ALUM-04
ALUM-05
ALUM-06
ALUM-07
ALUM-08
ALUM-09
ALUM-10
ALUM-11
ALUM-12
ALUM-13
ALUM-14
ALUM-15
ALUM-16
ALUM-17
ALUM-18

No. and Size


of Wire

Nominal
Diameter
(in)

Nominal
Diameter
(mm)

Breaking
Load
(lb)

Breaking
Load
(kg)

Weight
/MFT
(lb)

Weight
/km
(kg)

37 #5
37 #6
37 #7
37 #8
37 #9
37 #10
19 #5
19 #6
19 #7
19 #8
19 #9
19 #10
7 #5
7 #6
7 #7
7 #8
7 #9
7 #10

1.270
1.130
1.010
.899
.801
.713
.910
.810
.721
.642
.572
.509
.546
.486
.433
.385
.343
.306

32.30
28.80
25.70
22.90
20.30
17.90
23.10
20.60
18.30
16.30
14.50
12.90
13.90
12.40
11.00
9.78
8.71
7.76

142800
120200
100700
84200
66770
52950
73350
61700
51730
43240
34290
27190
27030
22730
19060
15930
12630
10020

647900
54500
45690
38190
30290
24020
33270
27990
23460
19610
15550
15550
12260
10310
8645
7226
5729
4545

2802
2222
1762
1398
1108
879
1430
1134
899.5
713.5
565.8
448.7
524.9
416.3
330.0
261.8
207.6
164.7

4170
3307
2623
2080
1649
1308
2129
1688
1339
1062
842.0
667.7
781.1
619.5
491.1
389.6
308.9
245.1

Resistance Resistance
/MFT
/km
@ 68F
@ 20F
(ohm)
(ohm)
.04247
.05356
.06754
.08516
.1074
.1354
.08224
.1037
.1308
.1649
.2079
.2622
.2264
.2803
.3535
.4458
.5621
.7088

.1394
.1757
.2216
.2794
.3523
.4443
.2698
.3402
.4290
.5409
.6821
.8601
.7426
.9198
1.160
1.463
1.844
2.325

Area
(in2)

Area
(mm2)

.96152
.76264
.60509
.47984
.38032
.30174
.49438
.39163
.31073
.24641
.19530
.15495
.18193
.14435
.11448
.09077
.07198
.05708

620.60
492.20
390.30
309.50
245.50
194.70
318.70
252.70
200.40
158.90
126.10
99.96
117.40
93.10
73.87
58.56
46.44
36.83

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

105
20140924

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Alumoclad
Steel Wire

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Alumoclad
Steel Wire
Item #

ALUM-19
ALUM-20
ALUM-21
ALUM-22
ALUM-23
ALUM-24
ALUM-25
ALUM-26
ALUM-27
ALUM-28
ALUM-29
ALUM-30
ALUM-31
ALUM-32
ALUM-33
ALUM-34
ALUM-35

No. and Size


of Wire

Nominal
Diameter
(in)

Nominal
Diameter
(mm)

Breaking
Load
(lb)

Breaking
Load
(kg)

Weight
/MFT
(lb)

Weight
/km
(kg)

7 #11
7 #12
3 #5
3 #6
3 #7
3 #8
3 #9
3 #10
#4
#5
#6
#7
#8
#9
#10
#11
#12

.272
.242
.392
.349
.311
.277
.247
.220
.2043
.1819
.1620
.1443
.1285
.1144
.1019
.0907
.0808

6.91
6.16
9.96
8.87
7.90
7.03
6.26
5.58
5.19
4.62
4.12
3.67
3.26
2.91
2.59
2.30
2.05

7945
6301
12230
10280
8621
72060
5715
4532
5081
4290
3608
3025
2529
2005
1590
1261
1000

3604
2858
5547
4663
3910
3269
2592
2056
2305
1946
1637
1372
1147
909
721
572
454

130.6
103.6
224.5
178.1
141.2
112.0
888.1
704.3
936.3
742.5
588.8
466.9
370.3
293.7
232.9
184.7
146.5

194.4
154.2
334.1
265.0
201.1
166.7
132.2
104.8
139.3
110.5
87.62
69.48
55.11
43.71
34.66
27.49
21.80

Resistance Resistance
/MFT
/km
@ 68F
@ 20F
(ohm)
(ohm)
.8938
2.932
1.127
3.697
.5177
1.699
.6528
2.142
.8232
2.701
1.038
3.406
1.309
4.294
1.651
5.415
1.222
4.009
1.541
5.056
1.943
6.375
2.450
8.038
3.089
10.13
3.986
12.78
4.912
16.12
6.194
20.32
7.811
25.63

Area
(in2)

Area
(mm2)

.04527
.03590
.07796
.06185
.04905
.03890
.03085
.02446
.03278
.02599
.02062
.01635
.01297
.01028
.00816
.00647
.00513

29.21
23.16
50.32
39.90
31.65
25.10
19.90
15.78
21.15
16.77
13.30
10.55
8.368
6.632
5.261
4.172
3.309

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
105
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Application
Power lines, telephone lines, railway signals, communication lines, towers, masts.
Construction
Type M alumoclad guy strand is an economical, corrosion resistant buying material for use on overhead line structures. The thick cladding of aluminum on each wire protects the high-strength steel
core from rusting and subsequent loss of strength. Costly maintenance is eliminated and the original safety factor of the guy is maintained throughout the life of the line.
The alumoclad steel wire used to make Type M guy strand is unique in that the aluminum cladding
thickness is guaranteed to be no less than 10% of the wire radius. Thus, a thick corrosion barrier that
is pure aluminum not zinc or and iron-aluminum alloy protects the steel core.
Another important feature of any coated or clad wire is the bond between the coating material and
the base metal. In the case of alumoclad steel wire, the aluminum cladding and steel core are joined
by a continuous ductile weld. This assures against cracking or separating of the protective aluminum form the steel core.
Type M alumoclad steel wire guy strand is easily handled and installed. It weighs less than any of
the other high-strength guying materials.
Specifications
A474 Standard Specification for Aluminum-Coated Steel Wire Strand
B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire
B416 Standard Specification for Concentric-Lay-Stranded Aluminumclad Steel Conductors

Item #

AGM-1
AGM-2
AGM-3
AGM-4
AGM-5
AGM-6
AGM-7
AGM-8
AGM-9
AGM-10
AGM-11
AGM-12
AGM-13
AGM-14
AGM-15
AGM-16
AGM-17
AGM-18
AGM-19

Designation

Construction
Nos.
(in)

AWG
(Equiv.)

Stranded
Diameter
(in)

Cross
Section
(in2)

Breaking
Load
(lb)

Weight
/MFT
(lb)

4 MG3
5 MG3
6 MG
6.6 MG
7 MG3
8 MG
5/16 in. MG3
10 MG
5/16 in. MG
11.5 MG
12.5 MG
3/8 in. MG
14 MG
16 MG
18 MG
7/16 in. MG
20 MG
1/2 in. MG
25 MG

3/0.102
3/0.114
7/0.081
7/0.083
3/0.128
7/0.191
3/0.141
7/0.102
7/0.104
7/0.110
7/0.114
7/0.121
7/0.121
7/0.128
7/0.139
7/0.145
7/0.148
7/0.165
7/0.173

3/10 AWG
3/9 AWG
7/12 AWG
N/A
3/8 AWG
7/11 AWG
3/7 AWG
7/10 AWG
N/A
N/A
7/9 AWG
N/A
N/A
7/8 AWG
N/A
7/7 AWG
N/A
N/A
N/A

0.220
0.247
0.242
0.249
0.277
0.272
5/16
0.306
5/16
0.330
0.343
3/8
0.363
0.386
0.417
7/16
0.444
1/2
0.519

0.0245
0.0306
0.0361
0.0379
0.0386
0.0455
0.0495
0.0572
0.0595
0.0665
0.0714
0.0792
0.0805
0.0901
0.1062
0.1156
0.1204
0.1497
0.1645

4,500
5,600
6,300
6,600
7,100
8,000
8,400
10,000
10,400
11,600
12,500
13,800
14,100
16,000
18,000
18,700
20,000
22,900
25,000

70.61
88.18
104.1
109.3
111.2
131.4
142.7
165.1
171.6
192.0
206.2
228.0
232.2
260.0
306.6
333.6
347.5
432.0
474.8

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

106
20140924

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Type M
Alumoclad Steel Wire
Guy Strand

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Applications
Messenger Wire, Overhead Ground or Static Wire, Guy Wire.
Grades
Utilities, Common, Siemens-Martin, High Strength and Extra High Strength
Finish Coatings
Class A, B and C and Bezinal, a superior corrosive coating of 5% Aluminum and 95% Zinc.
Specifications
Including but not limited to:
ASTM A-363 Zinc-Coated (Galvanized) Steel Overhead Ground Wire Strand
ASTM A-475 Zinc-Coated Steel Wire Strand
ASTM A-925 -5 % Aluminum-Mischmetal Alloy-Coated Steel Overhead Ground Wire Strand
ASTM A-855 Zinc-5 % Aluminum-Mischmetal Alloy-Coated Steel Wire Strand
ASTM A-640 Zinc-Coated Steel Strand for Messenger Support of Figure 8 Cable

Item #

Strand
Diameter
(in)

GW5-3/16-062
GW6-3/16-065
GW7-7/32-072
GW8-1/4-080
GW9-9/32-093
GW10-5 /16-104
GW11-5 /16-109
GW12-3/8-120
GW13-7/16-145
GW14-1/2-165
GW15-9/16-188
GW16-5/8-207
GW17-1/2-100
GW18-9/16-113
GW19-5/8-125
GW20-3/4-150
GW21-7/8-177
GW22-1-200

3/16
3/16
7/32
1/4
9/32
5/16
5/16
3/8
7/16
1/2
9/16
5/8
1/2
9/16
5/8
3/4
7/8
1

Coated
Number
Diameter of Wires
(in)
per Strand

0.062
0.065
0.072
0.080
0.093
0.104
0.109
0.120
0.145
0.165
0.188
0.207
0.100
0.113
0.125
0.150
0.177
0.200

7
7
7
7
7
7
7
7
7
7
7
7
19
19
19
19
19
19

Approx.
Utilities/ Common SiemensHigh
Strand Specification Grade
Martin
Strength
Weight Grade Min.
Min.
Grade Min. Grade Min.
/MFT
Breaking Breaking. Breaking Breaking
(lb)
Strength Strength Strength Strength
(lb)
(lb)
(lb)
(lb)
73
80
98
121
164
205
225
273
399
517
671
813
504
637
796
1155
1581
2073

2400

4600

6000
11500
18000
25000

1150

1540
1900
2570
3200

4250
5700
7400
9600
11600
7620
9640
11000
16000
21900
28700

1900

2560
3150
4250
5350

6950
9350
12100
15700
19100
12700
16100
18100
26200
35900
47000

2850

3850
4750
6400
8000

10800
14500
18800
24500
29600
19100
24100
28100
40800
55800
73200

Extra-High
Min.
Min.
Min.
Strength
Weight
Weight
Weight
Grade Min. of Coating of Coating of Coating
Breaking CLASS A CLASS B CLASS C
Strength
(lb)
(lb)
(lb)
(lb)
3990

5400
6650
8950
11200

15400
20800
26900
35000
42400
26700
33700
40200
58300
79700
104500

0.50
0.50
0.50
0.60
0.70
0.80
0.80
0.85
0.90
0.90
1.00
1.00
0.70
0.80
0.85
0.90
0.90
1.00

1.00
1.00
1.00
1.20
1.40
1.60
1.60
1.70
1.80
1.80
2.00
2.00
1.40
1.60
1.70
1.80
1.80
2.00

1.50
1.50
1.50
1.80
2.10
2.40
2.40
2.55
2.70
2.70
3.00
3.00
2.10
2.40
2.55
2.70
2.70
3.00

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

107
20160414

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

Galvanized
Guy Wire/Static Wire

GROUNDING CABLES/
STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TRANSMISSION & DISTRIBUTION CABLES


Table of Contents

Bare Aluminum Cables


ACSR ..................................................................................................................................401
ACSR/AW ...........................................................................................................................402
ACSS ...................................................................................................................................407
AAC ....................................................................................................................................403
AAAC 6201 Alloy ...............................................................................................................404
ACAR ...................................................................................................................................406
TP Twisted Pair ...................................................................................................................405
ACSR/TW.............................................................................................................................419
ACSS/TW.............................................................................................................................418
Solid Soft-Drawn Tie Wire..................................................................................................408
Covered AL Line Wire Weatherproof.................................................................................409
Packaging Information
ACSR and ACSR/AW ..........................................................................................................410
AAC .....................................................................................................................................411
AAAC 6201 Alloy ...............................................................................................................412
TP Twisted Pair....................................................................................................................413
Covered Line Wire ..............................................................................................................414
Covered Aerial Medium Voltage Cable (Spacer Cable or Tree Wire)
AAC 2 Layer 15kV ...............................................................................................................420
AAC 3 Layer 15kV-35kV ......................................................................................................421
AAC 3 Layer 35kV Electrical Properties ............................................................................426
Spacer Cable Technical Data for 3 Layer Compounds .....................................................427
AAAC 2 Layer 15kV ............................................................................................................422
AAAC 3 Layer 15kV-35kV ...................................................................................................423
ACSR 2 Layer 15kV.............................................................................................................424
ACSR 3 Layer 15kV-35kV....................................................................................................425
Copper Cables
Covered CU Line Wire Weatherproof................................................................................415
Cathodic Protection Cable .................................................................................................416
Transformer Riser Wire (Tap Wire) ....................................................................................417

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

400
20160523

TRANSMISSION.&
DISTRIBUTION CABLES

Bare Aluminum Code Name Finder .....................................................................................002

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Bare Aluminum
Code Name Finder

Akron
Alliance
Alliance TP
Alton
Ames
Ames TP
Amherst
Amherst TP
Anaheim
Anaheim TP
Arbutus
Arbutus TP
Aster
Aster TP
Azusa
Azusa TP
Bersimis/AW
Bittern
Bittern/AW
Bitterroot
Bluebell
Bluebell TP
Bluebird
Bluebird/AW
Bluebonnet
Bluejay
Bluejay TP
Bluejay/AW
Bobolink
Bobolink/AW
Brahma
Brahma/AW
Brant
Brant/AW
Bunting
Bunting/AW
Butte
Butte TP
Cairo
Camellia
Canary
Canary/AW
Canna
Canna TP
Canton
Cardinal
Cardinal/AW

Size

Product
Type

Catalog
Page

30.58
246.9
246.9
48.69
77.47
77.47
195.7
195.7
155.4
155.4
795
795
2/0
2/0
123.3
123.3
1361
1272
1272
2750
1034
1034
2156
2156
3500
1113
1113
1113
1431
1431
203.2
203.2
397.5
397.5
1193
1193
312.8
312.8
465.4
1000
900
900
397.5
397.5
394.5
954
954

AAAC-6201
AAAC-6201
TP-AAAC-6201
AAAC-6201
AAAC-6201
TP-AAAC-6201
AAAC-6201
TP-AAAC-6201
AAAC-6201
TP-AAAC-6201
AAC
TP-AAC
AAC
TP-AAC
AAAC-6201
TP-AAAC-6201
ACSR/AW
ACSR
ACSR/AW
AAC
AAC
TP-AAC
ACSR
ACSR/AW
AAC
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
ACSR/AW
AAAC-6201
TP-AAAC-6201
AAAC-6201
AAC
ACSR
ACSR/AW
AAC
TP-AAC
AAAC-6201
ACSR
ACSR/AW

404
404
405
404
404
405
404
405
404
405
403
405
403
405
404
405
402
401
402
403
403
405
401
402
403
401
405
402
401
402
401
402
401
402
401
402
404
405
404
403
401
402
403
405
404
401
402

Code
Word
Carnation
Catbird/AW
Cattail
Chickadee
Chickadee TP
Chickadee/AW
Chukar
Chukar/AW
Cochin
Cochin/AW
Cockscomb
Cockscomb TP
Columbine
Condor
Condor/AW
Coot
Coot/AW
Coreopsis
Cosmos
Cosmos TP
Cowslip
Crane/AW
Creeper TP
Crow/AW
Cuckoo
Cuckoo/AW
Curlew
Curlew/AW
Daffodil
Dahlia
Dahlia TP
Daisy
Daisy TP
Darien
Day Lily TP
Dipper
Dipper/AW
Dorking
Dorking/AW
Dotterel
Dotterel/AW
Dove
Dove TP
Dove/AW
Drake
Drake TP
Drake/AW

Size

Product
Type

Catalog
Page

1431
AAC
403
954
ACSR/AW
402
750
AAC
403
397.5
ACSR
401
397.5
TP-ACSR
405
397.5
ACSR/AW
402
1780
ACSR
401
1780
ACSR/AW
402
211.3
ACSR
401
211.3
ACSR/AW
402
900
AAC
403
900
TP-AAC
405
1352
AAC
403
795
ACSR
401
795
ACSR/AW
402
795
ACSR
401
795
ACSR/AW
402
1590
AAC
403
477
AAC
403
477
TP-AAC
405
2000
AAC
403
874.5
ACSR/AW
402
517
TP-AAC
405
715.5
ACSR/AW
402
795
ACSR
401
795
ACSR/AW
402
1034
ACSR
401
1034
ACSR/AW
402
350
AAC
403
556.5
AAC
403
556.5
TP-AAC
405
266.8
AAC
403
266.8
TP-AAC
405
559.5 AAAC-6201 404
596 TP-AAAC-6201 405
1352
ACSR
401
1352
ACSR/AW
402
190.8
ACSR
401
190.8
ACSR/AW
402
176.9
ACSR
401
176.9
ACSR/AW
402
556.5
ACSR
401
556.5
TP-ACSR
405
556.5
ACSR/AW
402
795
ACSR
401
795
TP-ACSR
405
795
ACSR/AW
402

Code
Word

Size

Duck/AW
Dunlin TP
Eagle
Eagle/AW
Egret
Egret/AW
Elgin
Falcon
Falcon/AW
Finch
Finch/AW
Flag
Flamingo
Flamingo TP
Flamingo/AW
Flicker
Flicker TP
Flicker/AW
Flint
Flycatcher TP
Gannet
Gannet/AW
Gladiolus
Gloxinia 12
Goldenrod
Goldentuft
Goose/AW
Grackle
Grackle/AW
Greeley
Grosbeak
Grosbeak/AW
Grouse
Guinea
Guinea/AW
Gull/AW
Hawk
Hawk TP
Hawk/AW
Hawkweed
Hawthorn
Hen
Hen/AW
Heron/AW
Heuchera
Hyacinth
Ibis

Product
Type

Catalog
Page

605
ACSR/AW
402
715.5
TP-ACSR
405
556.5
ACSR
401
556.5
ACSR/AW
402
636
ACSR
401
636
ACSR/AW
402
652.4 AAAC-6201 404
1590
ACSR
401
1590
ACSR/AW
402
1113
ACSR
401
1113
ACSR/AW
402
700
AAC
403
666.6
ACSR
401
666.6
TP-ACSR
405
666.6
ACSR/AW
402
477
ACSR
401
477
TP-ACSR
405
477
ACSR/AW
402
740.8
AAAC-6201 404
516.8 TP-AAAC-6201 405
666.6
ACSR
401
666.6
ACSR/AW
402
1511
AAC
403
666.6
TP-AAC
405
954
AAC
403
450
AAC
403
636
ACSR/AW
402
1193
ACSR
401
1193
ACSR/AW
402
927.2
AAAC-6201 404
636
ACSR
401
636
ACSR/AW
402
80.0
ACSR
401
159.0
ACSR
401
159
ACSR/AW
402
666.6
ACSR/AW
402
477
ACSR
401
477
TP-ACSR
405
477
ACSR/AW
402
1000
AAC
403
1193
AAC
403
477
ACSR
401
477
ACSR/AW
402
500
ACSR/AW
402
650
AAC
403
500
AAC
403
397.5
ACSR
401

TP is Twisted Pair Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

002
20140110

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

Bare Aluminum
Code Name Finder
Code
Word
Ibis TP
Ibis/AW
Iris
Iris TP
Jaeger TP
Jessamine
Joree
Kingbird
Kingbird TP
Kingbird/AW
Kinglet TP
Kittiwake TP
Kiwi
Kiwi/AW
Lapwing
Lapwing/AW
Lark
Lark/AW
Larkspur
Laurel
Leghorn
Leghorn/AW
Lilac
Lily TP
Linnet
Linnet TP
Linnet/AW
Lupine
Magnolia
Mallard
Mallard/AW
Marigold
Marigold TP
Martin
Martin/AW
Meadowsweet
Merlin
Merlin TP
Merlin/AW
Minorca
Minorca/AW
Mistletoe
Narcissus
Nasturtium
Nuthatch
Nuthatch/AW
Orchid

Size

Product
Type

Catalog
Page

397.5
397.5
2
2
228.2
1750
2513
636
636
636
556.5
596
2167
2167
1590
1590
397.5
397.5
1034
266.8
134.6
134.6
795
3
336.4
336.4
336.4
2500
954
795
795
1113
1114
1352
1352
600
336.4
336.4
336.4
110.8
110.8
556.5
1272
715.5
1511
1511
636

TP-ACSR
ACSR/AW
AAC
TP-AAC
TP-ACSR
AAC
ACSR
ACSR
TP-ACSR
ACSR/AW
TP-ACSR
TP-ACSR
ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
ACSR/AW
AAC
AAC
ACSR
ACSR/AW
AAC
TP-AAC
ACSR
TP-ACSR
ACSR/AW
AAC
AAC
ACSR
ACSR/AW
AAC
TP-AAC
ACSR
ACSR/AW
AAC
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
AAC
AAC
AAC
ACSR
ACSR/AW
AAC

405
402
403
405
405
403
401
401
405
402
405
405
401
402
401
402
401
402
403
403
401
402
403
405
401
405
402
403
403
401
402
403
405
401
402
403
401
405
402
401
402
403
403
403
401
402
403

Code
Word
Orchid TP
Oriole
Oriole/AW
Ortolan
Ortolan TP
Ortolan/AW
Osprey
Osprey TP
Osprey/AW
Ostrich
Ostrich/AW
Oxlip
Oxlip TP
Pansy
Pansy TP
Parakeet
Parakeet TP
Parakeet/AW
Parrot
Parrot/AW
Partridge
Partridge TP
Partridge/AW
Peachbell
Peacock
Peacock/AW
Pelican
Pelican TP
Pelican/AW
Penguin
Penguin TP
Penguin/AW
Peony
Petrel
Petrel/AW
Petunia
Pheasant
Pheasant/AW
Phlox
Phlox TP
Phoebe/AW
Pigeon
Pigeon TP
Pigeon/AW
Piper/AW
Plover
Plover/AW

Size

Product
Type

Catalog
Page

636
336.4
336.4
1034
1034
1034
556.5
556.5
556.5
300
300
4/0
4/0
1
1
556.5
556.5
556.5
1511
1511
266.8
266.8
266.8
6
605
605
477
477
477
4/0
4/0
4/0
300
101.8
101.8
750
1272
1272
3/0
3/0
300
3/0
3/0
3/0
300
1431
1431

TP-AAC
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
AAC
TP-AAC
AAC
TP-AAC
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
AAC
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
AAC
ACSR
ACSR/AW
AAC
ACSR
ACSR/AW
AAC
TP-AAC
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR/AW
ACSR
ACSR/AW

405
401
402
401
405
402
401
405
402
401
402
403
405
403
405
401
405
402
401
402
401
405
402
403
401
402
401
405
402
401
405
402
403
401
402
403
401
402
403
405
402
401
405
402
402
401
402

Code
Word
Poppy
Poppy TP
PtarmiganTP
Quail
Quail TP
Quail/AW
Rail
Rail/AW
Raven
Raven TP
Raven/AW
Redwing
Redwing/AW
Robin
Robin TP
Robin/AW
Rook
Rook TP
Rook/AW
Rose
Ruddy
Ruddy/AW
Sagebrush
Scoter
Scoter/AW
Siskin TP
Skylark/AW
Snapdragon
Sneezewort
Sparate
Sparate/AW
Sparrow
Sparrow TP
Sparrow/AW
Squab
Squab TP
Squab/AW
Starling
Starling/AW
Stilt
Stilt/AW
Surfbird TP
Swallow TP
Swallow/AW
Swan
Swan/AW
Swanate

Size

Product
Type

Catalog
Page

1/0
1/0
397.5
2/0
2/0
2/0
954
954
1/0
1/0
1/0
715.5
715.5
1
1
1
636
636
636
4
900
900
2250
636
636
666.6
1272
900
250
2
2
2
2
2
605
605
605
715.5
715.5
715.5
715.5
874.5
3
3
4
4
4

AAC
TP-AAC
TP-ACSR
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
AAC
ACSR
ACSR/AW
AAC
ACSR
ACSR/AW
TP-ACSR
ACSR/AW
AAC
AAC
ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR
ACSR/AW
TP-ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
ACSR

403
405
405
401
405
402
401
402
401
405
402
401
402
401
405
402
401
405
402
403
401
402
403
401
402
405
402
403
403
401
402
401
405
402
401
405
402
401
402
401
402
405
405
402
401
402
401

TP is Twisted Pair Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
002
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Bare Aluminum
Code Name Finder
Size

Product
Type

Catalog
Page

Swanate/AW
Swift
Swift/AW
Syringa
Tanager/AW
Tatler TP
Teal
Teal/AW
Tern
Tern TP

4
636
636
477
1034
477
605
605
795
795

ACSR/AW
ACSR
ACSR/AW
AAC
ACSR/AW
TP-ACSR
ACSR
ACSR/AW
ACSR
TP-ACSR

402
401
402
403
402
405
401
402
401
405

Code
Word
Tern/AW
Thrasher
Thrasher/AW
Trillium
Tulip
Tulip TP
Turacos TP
Turkey
Twinstone TP
Valerian

Size

Product
Type

Catalog
Page

795
2312
2312
3000
336.4
336.4
636
6
900
250

ACSR/AW
ACSR
ACSR/AW
AAC
AAC
TP-AAC
TP-ACSR
ACSR
TP-ACSR
AAC

402
401
402
403
403
405
405
401
405
403

Code
Word
Verbena
Violet TP
Waxwing
Waxwing TP
Waxwing/AW
Wood Duck
Wood Duck/AW
Zinnia

Size

Product
Type

Catalog
Page

700
715.5
266.8
266.8
266.8
605
605
500

AAC
TP-AAC
ACSR
TP-ACSR
ACSR/AW
ACSR
ACSR/AW
AAC

403
405
401
405
402
401
402
403

TP is Twisted Pair Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

002
20140110

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ACSR

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is
available with class A, B, or C galvanizing; aluminized aluminum coated (AZ); or aluminum-clad
(AW). Additional corrosion protection is available through the application of grease to the corer or
infusion of the complete cable with grease.
Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel
Reinforced (ACSR)
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
Current ratings are based on 75C conductor temperature, 25C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item #

Size
AWG

Turkey
Swan
Swanate
Sparrow
Sparate
Robin
Raven
Quail
Pigeon
Penguin
Waxwing
Partridge
Ostrich
Merlin
Linnet
Oriole
Chickadee
Brant
Ibis
Lark
Pelican
Flicker

6
4
4
2
2
1
1/0
2/0
3/0
4/0
266.8
266.8
300.0
336.4
336.4
336.4
397.5
397.5
397.5
397.5
477.0
477.0

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
O.D.
(lb)
(in)
(in)
(in)
6/1
6/1
7/1
6/1
7/1
6/1
6/1
6/1
6/1
6/1
18/1
26/7
26/7
18/1
26/7
30/7
18/1
24/7
26/7
30/7
18/1
24/7

0.0661
0.0834
0.0772
0.1052
0.0974
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.1013
0.1074
0.1367
0.1137
0.1059
0.1486
0.1287
0.1236
0.1151
0.1628
0.1410

0.0661
0.0834
0.1029
0.1052
0.1299
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.0788
0.0835
0.1367
0.0884
0.1059
0.1486
0.0858
0.0961
0.1151
0.1628
0.0940

0.0661
0.0834
0.1029
0.1052
0.1299
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.2364
0.2505
0.1367
0.2642
0.3117
0.1486
0.2574
0.2882
0.3453
0.1628
0.2820

0.198
0.250
0.257
0.316
0.325
0.354
0.398
0.447
0.502
0.563
0.609
0.642
0.680
0.683
0.720
0.741
0.743
0.772
0.783
0.806
0.814
0.846

24.5
39.0
39.0
62.0
62.0
78.2
98.7
124.3
156.7
197.7
250.3
251.7
282.9
315.8
317.1
318.2
373.1
375.0
374.7
375.8
447.8
450.1

Weight
/MFT
Steel
(lb)

Weight
/MFT
Total
(lb)

11.6
18.4
28.0
29.3
44.7
36.9
46.6
58.7
74.0
93.4
39.2
115.6
129.8
49.5
145.4
208.9
58.5
137.0
171.9
246.8
70.2
164.4

36.1
57.4
67
91.3
106.7
115.1
145.3
183
230.7
291.1
289.5
367.2
412.7
365.2
462.5
527.1
431.6
512
546.6
622.6
518
614.5

Rated Allowable
Breaking Ampacity
Strength
(amp)
(lb)
1190
1860
2360
2850
3640
3550
4380
5300
6620
8350
6880
11300
12700
8680
14100
17800
9940
14500
16300
20300
11800
17200

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Rating
(amp)

105
140
140
184
184
212
242
276
315
357
449
475
492
519
529
535
576
584
587
594
646
655

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

401
20160520

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR
offers optimal strength for line design. Variable steel core stranding enables desired strength to be
achieved without sacrificing ampacity.

TRANSMISSION &
DISTRIBUTION CABLES

ACSR
Item #

Hawk
Hen
Osprey
Parakeet
Dove
Eagle
Peacock
Squab
Wood Duck
Teal
Kingbird
Swift
Rook
Grosbeak
Scoter
Egret
Flamingo
Gannet
Stilt
Starling
Redwing
Coot
Cuckoo
Drake
Tern
Condor
Mallard
Ruddy
Canary
Rail
Cardinal
Ortolan
Curlew
Bluejay
Finch
Bunting
Grackle
Bittern
Pheasant
Dipper
Martin
Bobolink
Plover
Nuthatch
Parrot

Size
AWG

477.0
477.0
556.5
556.5
556.5
556.5
605.0
605.0
605.0
605.0
636.0
636.0
636.0
636.0
636.0
636.0
666.6
666.6
715.5
715.5
715.5
795.0
795.0
795.0
795.0
795.0
795.0
900.0
900.0
954.0
954.0
1033.5
1033.5
1113.0
1113.0
1192.5
1192.5
1272.0
1272.0
1351.5
1351.5
1431.0
1431.0
1510.5
1510.5

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
(O.D.)
(lb)
(in)
(in)
(in)
26/7
0.1354
0.1053
0.3159
0.858
449.6
30/7
0.1261
0.1261
0.3783
0.883
451.1
18/1
0.1758
0.1758
0.1758
0.879
522.2
24/7
0.1523
0.1015
0.3045
0.914
525.1
26/7
0.1463
0.1138
0.3414
0.927
525.0
30/7
0.1362
0.1362
0.4086
0.953
526.3
24/7
0.1588
0.1059
0.3177
0.953
570.9
26/7
0.1525
0.1186
0.3558
0.966
570.4
30/7
0.1420
0.1420
0.4260
0.994
572.0
30/19
0.1420
0.0852
0.4260
0.994
572.0
18/1
0.1880
0.1880
0.1880
0.940
597.2
36/1
0.1329
0.1329
0.1329
0.930
596.9
24/7
0.1628
0.1085
0.3255
0.977
600.0
26/7
0.1564
0.1216
0.3648
0.990
597.9
30/7
0.1456
0.1456
0.4368
1.019
601.4
30/19
0.1456
0.0874
0.4370
1.019
601.4
24/7
0.1667
0.1110
0.3330
1.000
629.1
26/7
0.1601
0.1245
0.3730
1.014
628.7
24/7
0.1727
0.1151
0.3453
1.036
675.2
26/7
0.1659
0.1290
0.3870
1.051
675.0
30/19
0.1544
0.0926
0.4630
1.081
676.3
36/1
0.1486
0.1486
0.1486
1.040
746.2
24/7
0.1820
0.1213
0.3640
1.092
749.9
26/7
0.1749
0.1360
0.4080
1.108
750.3
45/7
0.1329
0.0886
0.2548
1.063
749.8
54/7
0.1213
0.1213
0.3639
1.092
749.5
30/19
0.1628
0.0977
0.4885
1.140
751.9
45/7
0.1414
0.0943
0.2829
1.131
848.7
54/7
0.1291
0.1291
0.3873
1.162
849.0
45/7
0.1456
0.0971
0.2913
1.165
899.9
54/7
0.1329
0.1329
0.3987
1.196
900.7
45/7
0.1515
0.1010
0.3030
1.212
974.3
54/7
0.1383
0.1383
0.4149
1.245
974.3
45/7
0.1573
0.1049
0.3147
1.259
1050.0
54/19
0.1436
0.0862
0.4310
1.293
1056.0
45/7
0.1628
0.1085
0.3255
1.302
1125.0
54/19
0.1486
0.0892
0.4460
1.338
1130.0
45/7
0.1681
0.1121
0.3363
1.345
1200.0
54/19
0.1535
0.0921
0.4605
1.382
1206.0
45/7
0.1733
0.1155
0.3465
1.386
1275.0
54/19
0.1582
0.9049
0.4745
1.424
1281.0
45/7
0.1783
0.1189
0.3567
1.427
1350.0
54/19
0.1628
0.0977
0.4885
1.465
1357.0
45/7
0.1832
0.1221
0.3663
1.465
1425.0
54/19
0.1672
0.1003
0.5015
1.505
1431.0

Weight
/MFT
Steel
(lb)

Weight
/MFT
Total
(lb)

206.4
296.2
81.8
191.7
241.0
345.6
208.7
261.8
375.6
367.4
93.6
46.8
219.1
276.2
394.9
386.6
229.7
288.5
246.5
309.7
434.0
58.5
273.8
344.2
146.1
273.6
483.1
165.5
309.9
175.5
328.4
189.8
355.6
204.8
276.1
219.1
402.7
233.9
429.3
248.3
455.8
263.1
483.1
277.4
509.2

656
747.3
604.1
716.9
766
871.8
779.6
832.2
947.7
939.4
690.8
643.7
819.1
874.1
996.3
988
858.8
917.1
921.8
984.7
1110
804.7
1024
1094
895.9
1023
1235
1014
1149
1075
1228
1164
1330
1255
1432
1344
1533
1433
1635
1525
1737
1613
1840
1702
1940

Rated Allowable
Breaking Ampacity
Strength
(amp)
(lb)
19500
23800
13700
19800
22500
27800
21600
24300
28900
30000
15700
13800
22600
25200
30400
31500
23700
26400
25500
28400
34600
16800
27900
31500
22100
28200
38400
24400
31900
25900
33800
27700
36600
29800
39100
32000
41900
34100
43500
36200
46300
38300
49100
40100
51700

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Rating
(amp)

659
666
711
721
726
734
760
765
774
773
773
769
784
789
798
798
807
812
844
849
859
884
901
907
887
889
918
958
961
993
996
1043
1047
1092
1093
1139
1140
1184
1187
1229
1232
1272
1275
1313
1318

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
401
20150520

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSR
Size
AWG

Lapwing
1590.0
Falcon
1590.0
Chukar
1780.0
Bluebird
2156.0
Kiwi
2167.0
Thrasher
2312.0
Joree
2515.0
High Mechanical Strength
Grouse
80.0
Petrel
101.8
Minorca
110.8
Leghorn
134.6
Guinea
159.0
Dotterel
176.9
Dorking
190.8
Brahma
203.2
Cochin
211.3

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
O.D.
(lb)
(in)
(in)
(in)
45/7
0.1880
0.1253
0.3759
1.504
1498.0
54/19
0.1716
0.1030
0.5150
1.545
1507.0
84/19
0.1456
0.0874
0.4370
1.602
1688.0
84/19
0.1602
0.0961
0.4805
1.762
2044.0
72/7
0.1735
0.1157
0.3471
1.735
2055.0
76/19
0.1744
0.0814
0.4070
1.802
2191.0
76/19
0.1819
0.0849
0.4245
1.880
2384.0
8/1
12/7
12/7
12/7
12/7
12/7
12/7
16/19
12/7

0.1000
0.0921
0.0961
0.1059
0.1151
0.1214
0.1261
0.1227
0.1327

0.1670
0.0921
0.0961
0.1059
0.1151
0.1214
0.1261
0.0977
0.1327

0.1670
0.2763
0.2883
0.3177
0.3453
0.3642
0.3783
0.4885
0.3981

0.367
0.461
0.481
0.530
0.576
0.607
0.631
0.714
0.664

75.1
96.0
104.5
127.0
150.0
166.9
180.0
191.7
199.3

Weight
/MFT
Steel
(lb)

Weight
/MFT
Total
(lb)

Rated Allowable
Breaking Ampacity
Strength
(amp)
(lb)

Rating
(amp)

292.2
537.0
386.6
467.4
248.9
335.4
364.8

1793
2044
2975
2511
2303
2527
2749

42200
54500
51000
60300
49800
56700
61700

N/A
N/A
N/A
N/A
N/A
N/A
N/A

1354
1359
1453
1623
1607
1673
1751

73.9
158.0
172.1
208.9
246.8
274.6
296.3
485.0
328.2

149
254
276
336
396
441
476
675
527

5200
10400
11300
13600
16000
17300
18700
28400
20700

204
237
246
273
297
312
324
341
340

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

401
20150520

TRANSMISSION.&
DISTRIBUTION CABLES

Item #

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ACSR/AW

Construction
Aluminum 1350 H-19 wires, concentrically stranded about an aluminum-clad steel core wire (AW).
Specifications
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
ASTM B-502 Aluminum-Clad Steel Core Wire for Aluminum Conductors, Aluminum-Clad Steel
Reinforced
ASTM B-549 Aluminum Conductors Concentric-Lay-Stranded, Aluminum-Clad Steel Reinforced
(ACSR/AW)

Item #

Size
AWG

Petrel/AW
Minorca/AW
Leghorn/AW
Guinea/AW
Dotterel/AW
Dorking/AW
Brahma/AW
Cochin/AW
Swan/AW
Swanate/AW
Swallow/AW
Sparrow/AW
Sparate/AW
Robin/AW
Raven/AW
Quail/AW
Pigeon/AW
Penguin/AW
Waxwing/AW
Partridge/AW
Phoebe/AW
Ostrich/AW
Piper/AW
Merlin/AW
Linnet/AW
Oriole/AW

101.8
110.8
134.6
159
176.9
190.8
203.2
211.3
4
4
3
2
2
1
1/0
2/0
3/0
4/0
266.8
266.8
300
300
300
336.4
336.4
336.4

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
O.D.
(lb)
(in)
(in)
(in)
12/7
12/7
12/7
12/7
12/7
12/7
16/19
12/7
6/1
7/1
6/1
6/1
7/1
6/1
6/1
6/1
6/1
6/1
18/1
26/7
18/1
26/7
30/7
18/1
26/7
30/7

0.0921
0.0961
0.1059
0.1151
0.1214
0.1261
0.1227
0.1327
0.0834
0.0772
0.0937
0.1052
0.0974
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.1013
0.1291
0.1074
0.1000
0.1367
0.1137
0.1059

0.0921
0.0961
0.1059
0.1151
0.1214
0.1261
0.0977
0.1327
0.0834
0.1029
0.0937
0.1052
0.1299
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.0788
0.1291
0.0835
0.1000
0.1367
0.0884
0.1059

0.2763
0.2883
0.3177
0.3453
0.3642
0.3783
0.4885
0.3981
0.0834
0.1029
0.0094
0.1052
0.1295
0.1181
0.1327
0.1489
0.1672
0.1878
0.1217
0.2364
0.1291
0.2505
0.3000
0.1367
0.2642
0.3117

0.4610
0.4810
0.5300
0.5760
0.6070
0.6310
0.7140
0.6640
0.2500
0.2570
0.0281
0.3160
0.3240
0.3540
0.3980
0.4470
0.5020
0.5630
0.6080
0.6420
0.6460
0.6800
0.7000
0.6830
0.7200
0.7410

133.70
145.60
176.90
209.00
232.50
250.80
409.50
277.60
39.00
39.00
49.30
62.10
62.10
78.30
98.80
124.40
156.80
197.80
250.40
251.90
282.00
283.10
283.90
316.00
317.30
318.40

Weight
/MFT
AW
(lb)

Weight
/MFT
Total
(lb)

96.10
104.60
127.10
150.10
167.00
180.10
191.90
199.40
15.60
23.70
19.70
24.80
37.70
31.30
39.50
49.80
62.70
79.10
33.20
98.00
37.40
110.00
157.70
41.90
123.20
176.90

229.80
250.30
303.90
359.10
399.50
430.90
601.40
477.00
54.60
62.70
68.90
86.90
99.70
109.50
138.30
174.10
220.00
276.90
283.60
349.80
319.40
393.10
441.60
357.90
440.50
495.30

Resistance Allowable
/MFT Ampacity*
DC 20C
(amp)
(ohm)
0.143
0.131
0.108
0.091
0.082
0.076
0.066
0.069
0.390
0.380
0.309
0.245
0.239
0.195
0.154
0.122
0.097
0.077
0.064
0.062
0.057
0.055
0.054
0.050
0.049
0.048

281
297
335
372
398
418
464
445
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Rating*
(amp)

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
145
148
N/A
194
198
225
260
301
347
402
451
465
N/A
500
N/A
522
537
547

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

402
20150601

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
ACSR/AW cables are used for overhead transmission and distribution lines. Also, as neutral messenger for low voltage multiplex cables.

TRANSMISSION &
DISTRIBUTION CABLES

ACSR/AW
Item #

Chickadee/AW
Brant/AW
Ibis/AW
Lark/AW
Pelican/AW
Flicker/AW
Hawk/AW
Hen/AW
Heron/AW
Osprey/AW
Parakeet/AW
Dove/AW
Eagle/AW
Peacock/AW
Squab/AW
WoodDuck/AW
Teal/AW
Duck/AW
Kingbird/AW
Rook/AW
Grosbeak/AW
Scoter/AW
Egret/AW
Swift/AW
Goose/AW
Flamingo/AW
Gannet/AW
Gull/AW
Stilt/AW
Starling/AW
Redwing/AW
Crow/AW
Coot/AW
Cuckoo/AW
Drake/AW
Tern/AW
Condor/AW
Mallard/AW
Crane/AW
Ruddy/AW
Canary/AW
Catbird/AW
Rail/AW
Cardinal/AW
Tanager/AW

Size
AWG

397.5
397.5
397.5
397.5
477
477
477
477
500
556.5
556.5
556.5
556.5
605
605
605
605
605
636
636
636
636
636
636
636
666.6
666.6
666.6
715.5
715.5
715.5
715.5
795
795
795
795
795
795
874.5
900
900
954
954
954
1033.5

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
O.D.
(lb)
(in)
(in)
(in)
18/1
24/7
26/7
30/7
18/1
24/7
26/7
30/7
30/7
18/1
24/7
26/7
30/7
24/7
26/7
30/7
30/19
54/7
18/1
24/7
26/7
30/7
30/19
24/7
26/7
24/7
26/7
54/7
24/7
26/7
30/19
54.7
36/1
24/7
26/7
45/7
54/7
30/19
54/7
45/7
54/7
36/1
45/7
54/7
36/1

0.1486
0.1287
0.1236
0.1151
0.1628
0.1410
0.1354
0.1261
0.1291
0.1758
0.1523
0.1463
0.1362
0.1588
0.1525
0.1420
0.1420
0.1059
0.1880
0.1628
0.1564
0.1456
0.1456
0.1329
0.1085
0.1667
0.1601
0.1110
0.1727
0.1659
0.1544
0.1150
0.1486
0.1820
0.1749
0.1329
0.1213
0.1628
0.1272
0.1414
0.1291
0.1628
0.1456
0.1329
0.1694

0.1486
0.0858
0.0961
0.1151
0.1628
0.0940
0.1053
0.1261
0.1291
0.1758
0.1015
0.1138
0.1362
0.1059
0.1186
0.1420
0.0852
0.1059
0.1880
0.1085
0.1216
0.1456
0.0874
0.1329
0.1087
0.1110
0.1245
0.1110
0.1151
0.1290
0.0926
0.1150
0.1486
0.1213
0.1360
0.0886
0.1213
0.0977
0.1272
0.0943
0.1291
0.1628
0.0971
0.1329
0.1694

0.1486
0.2574
0.2882
0.3453
0.1628
0.2820
0.3159
0.3783
0.3870
0.1758
0.3045
0.3414
0.4086
0.3177
0.3558
0.4260
0.4260
0.3180
0.1880
0.3255
0.3648
0.4368
0.4370
0.1329
0.3260
0.3330
0.3730
0.3330
0.3453
0.3870
0.4630
0.3450
0.1486
0.3640
0.4080
0.2660
0.3639
0.4885
0.3810
0.2829
0.3873
0.1628
0.2913
0.3987
0.1694

0.7430
0.7720
0.7830
0.8060
0.8140
0.8460
0.8580
0.8830
0.9040
0.8790
0.9140
0.9270
0.9530
0.9530
0.9660
0.9940
0.9940
0.9530
0.9400
0.9770
0.9900
1.0190
1.0190
0.9300
0.9770
1.3330
1.0140
0.9990
1.0360
1.0510
1.0810
1.0350
1.0400
1.0920
1.1070
1.0630
1.0920
1.1400
1.4440
1.1310
1.1620
1.1400
1.1650
1.1960
1.1860

373.30
375.30
374.90
376.20
448.10
450.30
449.90
451.50
473.40
522.50
525.40
525.30
526.50
571.50
571.00
572.50
572.50
571.80
597.60
600.50
600.50
601.80
601.80
597.50
600.20
629.30
629.30
628.40
675.60
675.60
676.90
673.70
750.60
750.70
748.00
750.50
750.10
752.40
824.40
849.60
849.60
896.30
900.50
900.60
970.60

Weight
/MFT
AW
(lb)

Weight
/MFT
Total
(lb)

49.50
116.10
145.60
209.00
59.50
139.39
174.90
250.76
262.96
69.34
162.45
204.29
292.45
176.87
221.75
318.01
311.30
176.87
79.46
185.66
233.23
334.26
327.62
39.64
186.19
194.65
244.38
194.38
208.98
262.48
367.74
208.41
232.02
232.00
292.00
123.74
232.02
409.52
255.01
140.20
262.80
59.47
148.64
278.58
64.40

422.90
491.30
520.50
585.20
507.60
589.70
624.80
702.20
736.40
591.90
687.90
729.60
819.00
748.40
792.70
890.50
883.80
748.60
677.10
786.10
833.80
936.00
929.40
637.10
786.40
823.90
873.70
822.70
884.60
938.10
1044.60
882.10
982.60
982.70
1040.00
874.20
982.10
1161.90
1079.40
989.80
1112.40
955.80
1049.10
1179.20
1035.00

Resistance Allowable
/MFT Ampacity*
DC 20C
(amp)
(ohm)
0.043
0.042
0.041
0.041
0.036
0.035
0.035
0.034
0.032
0.031
0.030
0.030
0.029
0.027
0.027
0.027
0.027
0.027
0.027
0.026
0.026
0.025
0.025
0.027
0.026
0.025
0.025
0.025
0.023
0.023
0.023
0.023
0.021
0.021
0.022
0.021
0.021
0.020
0.019
0.019
0.018
0.018
0.018
0.017
0.017

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Rating*
(amp)

580
592
597
608
651
663
669
682
N/A
715
731
737
751
770
777
N/A
791
N/A
778
794
801
N/A
N/A
N/A
N/A
818
825
N/A
N/A
863
878
N/A
N/A
913
922
896
913
938
N/A
970
986
N/A
1003
1022
N/A

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
402
20150601

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSR/AW

Ortolan/AW
Curlew/AW
Bluejay/AW
Finch/AW
Bunting/AW
Grackle/AW
Skylark/AW
Bittern/AW
Pheasant/AW
Dipper/AW
Martin/AW
Bersimis/AW
Bobolink/AW
Plover/AW
Nuthatch/AW
Parrot/AW
Lapwing/AW
Falcon/AW
Chukar/AW
Bluebird/AW
Kiwi/AW
Thrasher/AW

Size
AWG

1033.5
1033.5
1113
1113
1192.5
1192.5
1272
1272
1272
1351.5
1351.5
1361
1431
1431
1510.5
1510.5
1590
1590
1780
2156
2167
2312

Stranding Diameter Diameter Diameter Diameter


Weight
(Al/Stl) Individual Individual Steel Core Complete
/MFT
Wire
Wire
(in)
Cable
Aluminum
Aluminum
Steel
O.D.
(lb)
(in)
(in)
(in)
45/7
54/7
45/7
54/19
45/7
54/19
36/1
45/7
54/19
45/7
54/19
42/7
45/7
54/19
45/7
54/19
45/7
54/19
84/19
84/19
72/7
76/19

0.1515
0.1383
0.1573
0.1436
0.1628
0.1486
0.1880
0.1681
0.1535
0.1733
0.1582
0.1799
0.1783
0.1628
0.1832
0.1672
0.1880
0.1716
0.1456
0.1602
0.1735
0.1744

0.1010
0.1383
0.1049
0.0862
0.1085
0.0892
0.1880
0.1121
0.0921
0.1155
0.9490
0.1000
0.1189
0.0977
0.1221
0.1003
0.1253
0.1030
0.0874
0.0961
0.1157
0.0814

0.3030
0.4149
0.3147
0.4310
0.3255
0.4460
0.1880
0.3363
0.4605
0.3465
0.4745
0.3000
0.3567
0.4885
0.3663
0.5015
0.3759
0.5150
0.4370
0.4805
0.3471
0.4070

1.2120
1.2450
1.2580
1.2910
1.3020
1.3380
1.3160
1.3450
1.3810
1.3860
1.4240
1.3800
1.4270
1.4650
1.4650
1.5050
1.5040
1.5450
1.6020
1.7620
1.7350
1.8020

975.00
975.20
1051.00
1056.00
1126.00
1131.00
1195.00
1201.00
1207.00
1276.00
1282.00
1284.00
1351.00
1358.00
1426.00
1432.00
1501.00
1509.00
1691.00
2045.00
2056.00
2193.00

Weight
/MFT
AW
(lb)

Weight
/MFT
Total
(lb)

160.81
301.65
173.47
318.54
185.66
341.34
79.30
198.12
363.69
210.41
386.10
157.69
222.93
409.52
235.05
431.59
247.64
454.93
327.62
396.10
211.13
284.30

1135.80
1276.80
1224.40
1374.60
1311.50
1472.30
1274.50
1398.70
1570.80
1486.40
1668.00
1441.20
1573.60
1767.10
1660.70
1863.80
1749.00
1963.60
2018.50
2441.10
2267.30
2477.40

Resistance Allowable
/MFT Ampacity*
DC 20C
(amp)
(ohm)
0.016
0.016
0.015
0.015
0.014
0.014
0.013
0.013
0.013
0.013
0.012
0.013
0.012
0.012
0.011
0.011
0.011
0.011
0.010
0.008
0.008
0.007

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Rating*
(amp)

1054
1074
1103
N/A
N/A
N/A
N/A
N/A
1216
N/A
N/A
N/A
1283
N/A
N/A
N/A
1365
N/A
N/A
N/A
N/A
N/A

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

402
20150601

TRANSMISSION.&
DISTRIBUTION CABLES

Item #

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ACSS

Construction
ACSS is a composite concentric-lay stranded conductor. Steel strands form the central core of the
conductor with one or more layers of aluminum 1350-0 wire stranded around it. The steel core carries most or all of the mechanical load of the conductor due to the (fully annealed or soft) temper
aluminum. Steel core wires are protected from corrosion by galvanizing, aluminizing, or mischmetal
alloy coating. Corrosion protection should be selected to suit the environment to which the conductor will be exposed. High strength steel core is also available.
Standards
ACSS conductor meets or exceeds the following ASTM specifications:
B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.
B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers for Electrical Purposes.
B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors,
Steel Reinforced (ACSR).
B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Use in Overhead Electrical Conductors.
B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS).
B958 Extra-High-Strength and Ultra-High-Strength Class A Zinc-5% Aluminum-Mischmetal AlloyCoated Steel Core
Wire for Use in Overhead Electrical Conductors.
Options
Regular-Strength Class C galvanized steel core
High-Strength Class A galvanized steel core
Extra-High-Strength Class A galvanized steel core
Ultra-High-Strength Class A galvanized steel core
Regular-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
Extra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
Ultra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
Aluminum-clad steel core
250C Operating Temperature rating utilizing either the zinc-5% aluminum mischmetal alloycoated steel core wires, or the aluminum-clad steel core wires.
Non-specular surface finish

Item #

Size Stranding Dia.


AWG
Al/St
Ind.
or
Wire
KCMIL
(in)

Partridge ACSS
Junco ACSS
Ostrich ACSS
Woodcock ACSS
Linnet ACSS
Oriole ACSS
Ptarmigan ACSS
Brant ACSS
Ibis ACSS
Lark ACSS

266.8
266.8
300.0
336.4
336.4
336.4
397.5
397.5
397.5
397.5

26 / 7
30 / 7
26 / 7
22 / 7
26 / 7
30 / 7
20 / 7
24 / 7
26 / 7
30 / 7

0.1013
0.0943
0.1074
0.1237
0.1137
0.1059
0.1410
0.1287
0.1236
0.1151

Dia.
Ind.
Wire
(in)

Dia.
Steel
Core
(in)

0.0788
0.0943
0.0835
0.0687
0.0884
0.1059
0.0627
0.0858
0.0961
0.1151

0.2364
0.2829
0.2505
0.2061
0.2652
0.3177
0.1881
0.2574
0.2883
0.3453

Dia.
Weight
Weight
Complete
/MFT
/MFT
Cable Aluminum Steel
(in)
(lb)
(lb)
0.642
0.660
0.680
0.701
0.720
0.741
0.752
0.772
0.783
0.806

251.3
251.3
282.5
317.1
316.6
317.7
374.5
374.4
374.1
375.3

115.6
165.5
129.8
84.8
145.5
208.7
73.2
137.0
171.9
246.6

Weight
/MFT
Total
(lb)

Rated
Resist.
Resist. Ampacity
Strength DC@20C AC@75C
(lb)
/MFT
/MFT
(ohm)
(ohm)

366.9
416.8
412.3
401.9
462.1
526.4
447.7
511.4
546.0
621.9

8,880
11,700
10,000
7,610
11,200
14,800
7,090
11,000
13,000
17,500

0.0619
0.0615
0.0551
0.0495
0.0491
0.0488
0.0421
0.0417
0.0416
0.0413

0.0761
0.0756
0.0677
0.0609
0.0604
0.0600
0.0518
0.0514
0.0512
0.0508

812
822
877
933
945
957
1034
1047
1054
1068

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

407
20140925

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Used for overhead distribution and transmission lines. Designed to operate continuously at elevated temperatures up to 250C without loss of strength. It sags less under emergency electrical
loadings than ASCR; it is self-damping if prestretched during installation, and the final sags are not
affected by long term creep of aluminum. The advantages make ACSS especially useful in reconductoring applications requiring increased current with existing tensions and clearances, new line
applications where structures can be economized because of reduced conductor sag, new line applications requiring high emergency loadings, and lines where aeolian vibration is a problem.

TRANSMISSION &
DISTRIBUTION CABLES

ACSS
Item #

Size Stranding Dia.


AWG
Al/St
Ind.
or
Wire
KCMIL
(in)

Tailorbird ACSS
477.0
Flicker ACSS
477.0
Hawk ACSS
477.0
Hen ACSS
477.0
Sapsucker ACSS 556.5
Parakeet ACSS
556.5
Dove ACSS
556.5
Eagle ACSS
556.5
Peacock ACSS
605.0
Squab ACSS
605.0
Wood Duck ACSS 605.0
Teal ACSS
605.0
Goldfinch ACSS 636.0
Rook ACSS
636.0
Grosbeak ACSS 636.0
Scoter ACSS
636.0
Egret ACSS
636.0
Flamingo ACSS 666.6
Gannet ACSS
666.6
Stilt ACSS
715.5
Starling ACSS
715.5
Redwing ACSS
715.5
Cuckoo ACSS
795.0
Drake ACSS
795.0
Macaw ACSS
795.0
Tern ACSS
795.0
Condor ACSS
795.0
Mallard ACSS
795.0
Ruddy ACSS
900.0
Canary ACSS
900.0
Corncrake ACSS 954.0
Redbird ACSS
954.0
Rail ACSS
954.0
Towhee ACSS
954.0
Canvasback ACSS 954.0
Snowbird ACSS 1033.5
Ortolan ACSS
1033.5
Curlew ACSS
1033.5
Bluejay ACSS
1113.0
Finch ACSS
1113.0
Cardinal ACSS
954.0
Bunting ACSS
1192.5
Grackle ACSS
1192.5
Bittern ACSS
1272.0
Pheasant ACSS 1272.0
Dipper ACSS
1351.0

20 / 7
24 / 7
26 / 7
30 / 7
22 / 7
24 / 7
26 / 7
30 / 7
24 / 7
26 / 7
30 / 7
30 / 19
22 / 7
24 / 7
26 / 7
30 / 7
30 / 19
24 / 7
26 / 7
24 / 7
26 / 7
30 / 19
24 / 7
26 / 7
42 / 7
45 / 7
54 / 7
30 / 19
45 / 7
54 / 7
20 / 7
24 / 7
45 / 7
48 / 7
30 / 19
42 / 7
45 / 7
54 / 19
45 / 7
54 / 19
54 / 7
45 / 7
54 / 19
45 / 7
54 / 19
45 / 7

0.1544
0.1410
0.1354
0.1261
0.1590
0.1523
0.1463
0.1362
0.1588
0.1525
0.1420
0.1420
0.1700
0.1628
0.1564
0.1456
0.1456
0.1667
0.1601
0.1727
0.1659
0.1544
0.1820
0.1749
0.1376
0.1329
0.1213
0.0628
0.1414
0.1291
0.2184
0.1994
0.1456
0.1410
0.1783
0.1569
0.1515
0.1383
0.1573
0.1436
0.1329
0.1628
0.1486
0.1681
0.1535
0.1733

Dia.
Ind.
Wire
(in)

Dia.
Steel
Core
(in)

0.0686
0.0940
0.1053
0.1261
0.0883
0.1015
0.1138
0.1362
0.1059
0.1186
0.1420
0.0852
0.0944
0.1085
0.1216
0.1456
0.0874
0.1111
0.1245
0.1151
0.1290
0.0926
0.1213
0.1360
0.0764
0.0886
0.1213
0.0977
0.0943
0.1291
0.0971
0.1329
0.0971
0.1097
0.1070
0.0872
0.1010
0.1383
0.1049
0.0862
0.1329
0.1085
0.0892
0.1121
0.0921
0.1155

0.2058
0.2820
0.3159
0.3783
0.2649
0.3045
0.3414
0.4068
0.3177
0.3558
0.4260
0.4260
0.2832
0.3255
0.3648
0.4368
0.4370
0.3333
0.3735
0.3453
0.3870
0.4630
0.3639
0.4080
0.2292
0.2658
0.3639
0.4885
0.2829
0.3873
0.2913
0.3987
0.2913
0.3291
0.5350
0.2616
0.3030
0.4149
0.3747
0.4310
0.3987
0.3255
0.4460
0.3363
0.4605
0.3465

Dia.
Weight
Weight
Complete
/MFT
/MFT
Cable Aluminum Steel
(in)
(lb)
(lb)
0.823
0.846
0.858
0.883
0.901
0.914
0.927
0.953
0.953
0.966
0.994
0.994
0.963
0.977
0.990
1.019
1.019
1.000
1.014
1.036
1.051
1.081
1.092
1.108
1.055
1.063
1.092
1.140
1.131
1.162
1.165
1.196
1.165
1.175
1.248
1.203
1.212
1.245
1.258
1.293
1.196
1.302
1.338
1.345
1.382
1.386

449.1
449.4
449.0
450.4
523.9
524.3
524.2
525.5
570.0
569.5
571.2
571.2
598.9
599.1
599.0
600.5
600.5
628.2
627.7
674.2
674.0
675.3
748.8
749.1
749.0
748.6
748.4
750.7
847.4
847.7
898.5
898.8
898.5
898.8
900.5
973.9
972.8
972.8
1048.7
1053.9
898.3
1123.4
1128.6
1197.7
1204.3
1272.9

87.6
164.5
206.4
296.0
145.1
191.8
241.0
345.3
208.7
261.8
375.3
367.5
165.9
219.1
275.2
394.6
386.7
229.7
288.5
246.6
309.7
434.1
273.9
344.3
108.6
146.1
273.9
483.2
165.5
310.2
175.5
328.7
175.5
224.0
579.6
141.5
189.9
356.0
204.8
376.1
328.7
219.1
402.8
233.9
429.4
248.3

Weight
/MFT
Total
(lb)

Rated
Resist.
Resist. Ampacity
Strength DC@20C AC@75C
(lb)
/MFT
/MFT
(ohm)
(ohm)

536.7
613.9
655.4
746.4
669.0
716.1
765.2
870.8
778.7
831.3
946.5
938.7
764.8
818.2
874.2
995.1
987.2
857.9
916.2
920.8
983.7
1109.4
1022.7
1093.4
857.6
894.7
1022.3
1233.9
1012.9
1157.9
1074.0
1227.5
1074.0
1122.8
1480.1
1115.4
1162.7
1328.8
1253.5
1430.0
1227.0
1342.5
1531.4
1431.6
1633.7
1521.2

8,490
13,000
15,600
21,000
12,600
15,200
18,200
24,500
16,500
19,700
26,100
26,600
14,100
17,300
20,700
27,400
28,000
18,200
21,700
19,500
23,300
30,800
21,700
25,900
11,800
14,200
16,600
34,300
15,800
24,600
16,700
26,000
16,700
19,700
41,100
15,400
18,100
28,200
19,500
30,400
26,000
20,900
32,600
22,300
34,100
23,700

0.0351
0.0348
0.0346
0.0344
0.0299
0.0298
0.0297
0.0295
0.0274
0.0273
0.0271
0.0272
0.0262
0.0261
0.0260
0.0258
0.0258
0.0249
0.0248
0.0232
0.0231
0.0230
0.0209
0.0209
0.0211
0.0210
0.0209
0.0207
0.0186
0.0184
0.0175
0.0174
0.0175
0.0175
0.0172
0.0162
0.0162
0.0161
0.0150
0.0150
0.0174
0.0140
0.0140
0.0131
0.0131
0.0124

0.0433
0.0429
0.0427
0.0424
0.0370
0.0368
0.0366
0.0363
0.0339
0.0337
0.0334
0.0335
0.0324
0.0322
0.0321
0.0318
0.0319
0.0308
0.0306
0.0287
0.0286
0.0284
0.0259
0.0257
0.0262
0.0263
0.0026
0.0255
0.0233
0.0236
0.0219
0.0217
0.0220
0.0218
0.0214
0.0204
0.0204
0.0206
0.0190
0.0193
0.0223
0.0178
0.0180
0.0167
0.0169
0.0158

1165
1180
1188
1204
1297
1306
1315
1331
1379
1389
1407
1406
1415
1425
1435
1454
1453
1470
1480
1540
1550
1570
1650
1662
1621
1618
1618
1683
1755
1756
1834
1859
1824
1842
1897
1924
1921
1924
2017
2015
1825
2110
2108
2200
2200
2289

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
407
20140925

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSS
Size Stranding Dia.
AWG
Al/St
Ind.
or
Wire
KCMIL
(in)

Martin ACSS
1351.0
Bobolink ACSS
1431.0
Plover ACSS
1431.0
Nuthatch ACSS 1510.0
Parrot ACSS
1510.0
Ratite ACSS
1590.0
Lapwing ACSS
1590.0
Falcon ACSS
1590.0
Chukar ACSS
1780.0
Mockingbird ACSS 2034.0
Roadrunner ACSS 2057.0
Bluebird ACSS
2156.0
Kiwi ACSS
2167.0
Thrasher ACSS 2312.0
Joree ACSS
2515.0

54 / 19
45 / 7
54 / 19
45 / 7
54 / 19
42 / 7
45 / 7
54 / 19
84 / 19
72 / 7
76 / 19
84 / 19
72 / 7
76 / 19
76 / 19

0.1582
0.1783
0.1628
0.1832
0.1672
0.1946
0.1880
0.1716
0.1456
0.1681
0.1645
0.1602
0.1735
0.1744
0.1819

Dia.
Ind.
Wire
(in)

Dia.
Steel
Core
(in)

0.0949
0.1189
0.0977
0.1221
0.1003
0.1081
0.1253
0.1030
0.0874
0.1121
0.0768
0.0961
0.1157
0.0814
0.0849

0.4745
0.3567
0.4885
0.3663
0.5015
0.3243
0.3759
0.5150
0.4370
0.3363
0.3840
0.4805
0.3471
0.4070
0.4245

Dia.
Weight
Weight
Complete
/MFT
/MFT
Cable Aluminum Steel
(in)
(lb)
(lb)
1.424
1.427
1.465
1.466
1.505
1.492
1.504
1.544
1.602
1.681
1.700
1.762
1.735
1.802
1.880

1279.1
1347.5
1354.6
1422.5
1428.8
1498.1
1498.1
1505.0
1685.4
1925.7
1946.5
2040.4
2051.4
2187.9
2380.1

455.9
263.1
483.2
277.5
509.2
217.5
292.2
537.0
386.7
233.9
298.6
467.5
249.2
335.4
364.9

Weight
/MFT
Total
(lb)

Rated
Resist.
Resist. Ampacity
Strength DC@20C AC@75C
(lb)
/MFT
/MFT
(ohm)
(ohm)

1735.0
1610.6
1837.8
1700.0
1938.0
1715.6
1790.3
2042.0
2072.1
2159.6
2245.1
2507.9
2300.6
2523.3
2745.0

36,200
25,100
38,400
26,500
40,500
23,400
27,900
42,600
35,400
27,200
31,700
42,100
29,000
35,600
38,700

0.0123
0.0117
0.0117
0.0111
0.0110
0.0105
0.0105
0.0105
0.0094
0.0083
0.0082
0.0078
0.0078
0.0073
0.0067

0.0160
0.0150
0.0151
0.0143
0.0144
0.0136
0.0136
0.0137
0.0122
0.0110
0.0108
0.0103
0.0104
0.0098
0.0092

2288
2375
2375
2459
2460
2543
2543
2545
2751
2960
2992
3106
3080
3218
3390

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

407
20140925

TRANSMISSION.&
DISTRIBUTION CABLES

Item #

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

AAC

Construction
Aluminum alloy 1350-H19 wires, concentrically stranded.
Specifications
AAC bare conductors meet or exceed the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
Current ratings are based on 75C conductor temperature, 25C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item #

Size
AWG

No. of
Wires

CLASS

Diameter
Individual
Wire
(in)

Diameter
Complete
Cable O.D.
(in)

Cross
Sectional
Area
(in2)

Weight
/MFT
(lb)

Rated
Breaking
Strength
(lb)

Peachbell
Rose
Iris
Pansy
Poppy
Aster
Phlox
Oxlip
Sneezewort
Valerian
Daisy
Laurel
Peony
Tulip
Daffodil
Canna
Goldentuft
Cosmos
Syringa
Zinnia
Hyacinth

6
4
2
1
1/0
2/0
3/0
4/0
250
250
266.8
266.8
300
336.1
350
397.5
450
477
477
500
500

7
7
7
7
7
7
7
7
7
19
7
19
19
19
19
19
19
19
37
19
37

A
A
A & AA
A & AA
A & AA
A & AA
A & AA
A & AA
AA
A
A & AA
A
A
A
A
A & AA
AA
AA
A
AA
A

.0612
.0772
.0974
.1093
.1228
.1379
.1548
.1739
.1890
.1147
.1953
.1185
.1257
.1331
.1357
.1447
.1538
.1584
.1135
.1622
.1162

.184
.232
.292
.328
.368
.414
.464
.522
.567
.574
.586
.593
.629
.666
.679
.724
.769
.793
.795
.811
.813

.0206
.0328
.0521
.0657
.0829
.1045
.1318
.1662
.1964
.1964
.2095
.2095
.2356
.2642
.2749
.3122
.3534
.3746
.3746
.3927
.329

24.6
39.2
62.3
99.1
78.5
124.9
157.5
198.6
234.7
234.7
250.5
250.5
286.1
315.8
328.6
373.2
422.4
447.8
447.8
469.4
469.4

563
881
1350
1640
1990
2510
3040
3830
4520
4660
4830
4970
5480
6150
6390
7110
7890
8360
8690
8760
9110

Resistance Resistance
/MFT
/MFT
DC 20C
AC 75C
(ohm)
(ohm)
.658
.414
.260
.207
.164
.130
.103
.0817
.0691
.0691
.0648
.0648
.0576
.0514
.0494
.0435
.0384
.0362
.0362
.0346
.0346

.805
.506
.318
.252
.202
.159
.126
.0999
.0846
.0846
.0793
.0793
.0706
.0630
.0605
.0534
.0472
.0445
.0445
.0425
.0425

Rating
(amp)

103
138
185
214
247
286
331
383
425
426
443
444
478
513
526
570
616
639
639
658
658

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

403
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Stranded 1350 aluminum conductors shown in this section of data are classified as follows:
Class AA For bare conductors usually used in overhead lines.
Class A For conductors to be covered with weather-resistant materials and for bare conductors
where greater flexibility is required.Compact strand conductor for use in bare overhead applications
or for use with weather-resistant coverings or insulations is also available.
Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least
flexible, C the most flexible.

TRANSMISSION &
DISTRIBUTION CABLES

AAC
Item #

Dahlia
Mistletoe
Meadowsweet
Orchid
Heuchera
Verbena
Flag
Violet
Nasturtium
Petunia
Cattail
Arbutus
Lilac
Cockscomb
Snapdragon
Magnolia
Goldenrod
Hawkweed
Camellia
Bluebell
Larkspur
Marigold
Hawthorn
Narcissus
Columbine
Carnation
Gladiolus
Coreopsis
Jessamine
Cowslip
Sagebrush
Lupine
Bitterroot
Trillium
Bluebonnet

Size
AWG

No. of
Wires

CLASS

Diameter
Individual
Wire
(in)

Diameter
Complete
Cable O.D.
(in)

Cross
Sectional
Area
(in2)

Weight
/MFT
(lb)

Rated
Breaking
Strength
(lb)

556.5
556.5
600
636
650
700
700
715.5
715.5
750
750
795
795
900
900
954
954
1000
1000
1033.5
1033.5
1113
1192.5
1272
1351.5
1431
1510.5
1590
1750
2000
2250
2500
2750
3000
3500

19
37
37
37
37
37
61
37
61
37
61
37
61
37
61
37
61
37
61
37
61
61
61
61
61
61
61
61
61
91
91
91
91
127
127

AA
A
A & AA
A & AA
AA
AA
A
AA
A
AA
A
AA
A
AA
A
AA
A
AA
A
AA
A
A & AA
A & AA
A & AA
A & AA
A & AA
A & AA
AA
AA
A
A
A
A
A
A

.1711
.1226
.1273
.1311
.1326
.1375
.1071
.1391
.1083
.1424
.1109
.1446
.1142
.1560
.1215
.1606
.1251
.1644
.1280
.1671
.1302
.1351
.1398
.1444
.1489
.1532
.1574
.1614
.1694
.1482
.1572
.1657
.1739
.1537
.1660

.856
.858
.891
.918
.928
.963
.964
.974
.975
.997
.998
1.026
1.028
1.092
1.094
1.124
1.126
1.150
1.152
1.170
1.172
1.216
1.258
1.300
1.340
1.379
1.417
1.454
1.525
1.630
1.729
1.823
1.913
1.996
2.158

.4371
.4371
.4712
.4995
.5105
.5498
.5498
.5620
.5620
.5891
.5891
.6244
.6244
.7069
.7069
.7493
.7493
.7854
.7854
.8117
.8117
.8742
.9366
.9990
1.062
1.124
1.186
1.249
1.374
1.571
1.767
1.964
2.160
2.356
2.749

522.4
522.4
563.2
597.0
610.2
657.1
657.1
671.7
671.7
704.0
704.0
746.3
746.3
844.9
844.9
895.6
895.6
938.7
938.7
970.2
970.2
1045
1119
1194
1269
1343
1418
1493
1643
1877
2131
2370
2607
2844
3350

9750
9940
10700
11400
11600
12500
12900
12800
13100
13100
13500
13900
14300
15400
15900
16400
16900
17200
17700
17700
18300
19700
21000
22000
23400
24300
25600
27000
29700
32200
37500
41900
46100
50300
58700

Resistance Resistance
/MFT
/MFT
DC 20C
AC 75C
(ohm)
(ohm)
.0311
.0311
.0288
.0272
.0266
.0247
.0247
.0242
.0242
.0230
.0230
.0217
.0217
.0192
.0192
.0181
.0181
.0173
.0173
.0167
.0167
.0155
.0145
.0136
.0128
.0121
.0144
.0109
.00988
.00864
.00776
.00698
.00635
.00582
.00499

.0382
.0382
.0355
.0335
.0328
.0305
.0305
.0299
.0299
.0286
.0286
.0271
.0270
.0239
.0239
.0226
.0226
.0216
.0216
.0210
.0210
.0195
.0183
.0173
.0163
.0155
.0147
.0141
.0129
.0115
.0105
.00969
.00900
.00834
.00756

Rating
(amp)

703
704
738
765
775
812
812
823
823
847
847
878
879
948
948
982
983
1010
1011
1031
1032
1079
1124
1169
1212
1253
1294
1333
1408
1518
1612
1706
1793
1874
2024

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
403
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

AAAC 6201 Alloy

Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399,
are concentric-lay stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade
aluminum conductors, but without a steel core. The DC resistance at 20C of the 6201-T81 conductors and of the standard ACSRs of the same diameter are approximately the same. Conductors of
the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors
of 1350-H19 grade aluminum.
Specifications
AAAC bare conductor meets or exceeds the following ASTM specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
Current ratings are based on 75C conductor temperature, 25C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption

Item #

Akron
Alton
Ames
Azusa
Anaheim
Amherst
Alliance
Butte
Canton
Cairo
Darien
Elgin
Flint
Greely

Size KCM
KCM

Strand

Approx EC
Cond. with
Equivalent
Resistance

Stranding

Diameter
Individual
Wire
(in)

Diameter
Complete
Cable
(in)

Cross
Sectional
Area
(in2)

Weight
/MFT
(lb)

Rated
Breaking
Strength
(lb)

Rating
(amp)

30.58
48.69
77.47
123.3
155.4
195.7
246.9
312.8
394.5
465.4
559.5
652.4
740.8
927.2

7/w
7/w
7/w
7/w
7/w
7/w
7/w
19/w
19/w
19/w
19/w
19/w
37/w
37/w

6
4
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477.0
556.5
636.0
795.0

6/1
6/1
6/1
6/1
6/1
6/1
6/1
26/7
26/7
26/7
26/7
26/7
26/7
26/7

.0661
.0834
.1052
.1327
.1490
.1672
.1878
.1283
.1441
.1565
.1716
.1853
.1415
.1583

.198
.250
.316
.398
.447
.502
.563
.642
.721
.783
.858
.927
.991
1.108

.0240
.0382
.0608
.0968
.1221
.1537
.1939
.2456
.3098
.3655
.4394
.5124
.5818
.7282

28.7
45.7
72.7
115.7
145.9
183.7
231.8
293.6
370.3
436.9
525.2
612.4
695.5
870.4

1110
1760
2800
4460
5390
6790
8560
11000
13300
15600
18800
21900
24400
30500

107
143
191
256
296
342
395
460
532
590
663
729
790
908

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

404
20160418

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a highstrength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ACAR

Construction
Concentric-stranded cable formed by a core of 6201-T81 aluminum alloy wires surrounded by 1350
H-19 aluminum wires concentrically stranded over the alloy core. Some designs have 1350 aluminum wires and 6201 alloy wires intercalated in the same layer.
Features
Very good ratio Tensile Strength to Weight. Highly resistant to corrosion.
Standards
B230 Aluminum 1350-H19 Wire for Electrical Purposes.
B398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes.
B524 Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR,
1350/6201).

Item #

ACAR-355.0
ACAR-465.9
ACAR-503.6
ACAR-653.1
ACAR-739.8
ACAR-739.8
ACAR-853.7
ACAR-853.7
ACAR-927.2
ACAR-927.2
ACAR-1024.5
ACAR-1024.5
ACAR-1081.0
ACAR-1081.0
ACAR-1109.0
ACAR-1109.0
ACAR-1172.0
ACAR-1172.0
ACAR-1197.0
ACAR-1197.0
ACAR-1280.0
ACAR-1280.0
ACAR-1361.0
ACAR-1527.0
ACAR-1703.0
ACAR-1933.0
ACAR-2267.0
ACAR-2493.0
ACAR-2493.0

Size
KCMIL

Stranding
(EC/6201)

Diameter
Individual
Wires 6201
(in)

Diameter
Individual
Wires 1350
(in)

Diameter
Complete
Cable
(in)

Weight
/MFT
(lb)

Rated
Strength
(lb)

Resistance.
DC@20C
(ohms)

Resistance
AC@75C
(ohms)

Allowable
Ampacity
(amp)

355.0
465.9
503.6
653.1
739.8
739.8
853.7
853.7
927.2
927.2
1024.5
1024.5
1081.0
1081.0
1109.0
1109.0
1172.0
1172.0
1197.0
1197.0
1280.0
1280.0
1361.0
1527.0
1703.0
1933.0
2267.0
2493.0
2493.0

12/7
12/7
12/7
12/7
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
30/7
18/19
42/19
42/19
42/19
42/19
42/19
72/19
54/37

0.1367
0.1566
0.1628
0.1854
0.1414
0.1414
0.1519
0.1519
0.1583
0.1583
0.1664
0.1664
0.1709
0.1709
0.1731
0.1731
0.1780
0.1780
0.1799
0.1799
0.1860
0.1860
0.1494
0.1582
0.1671
0.1780
0.1928
0.1655
0.1655

0.1367
0.1566
0.1628
0.1854
0.1414
0.1414
0.1519
0.1519
0.1583
0.1583
0.1664
0.1664
0.1709
0.1709
0.1731
0.1731
0.1780
0.1780
0.1799
0.1799
0.1860
0.1860
0.1494
0.1582
0.1671
0.1780
0.1928
0.1655
0.1655

0.6830
0.7830
0.8140
0.9270
0.9900
0.9900
1.0630
1.0630
1.1080
1.1080
1.1650
1.1650
1.1960
1.1960
1.2120
1.2120
1.2460
1.2460
1.2590
1.2590
1.3020
1.3020
1.3440
1.4240
1.5040
1.6020
1.7350
1.8210
1.8210

332.1
435.8
471.1
611.0
692.7
691.6
799.3
798.0
868.2
866.7
959.3
957.7
1012.1
1010.5
1038.4
1036.6
1097.3
1095.5
1120.8
1118.9
1198.5
1196.5
1273.6
1428.8
1593.5
1808.8
2142.0
2356.9
2354.5

8500
11000
11900
15400
15300
18800
17500
21500
19000
23400
20900
25800
22100
27200
22700
27900
24000
29500
24500
30200
26200
32200
30300
33600
37500
42500
49900
50400
57600

0.0514
0.0392
0.0362
0.0279
0.0240
0.0252
0.0208
0.0218
0.0192
0.0201
0.0173
0.0182
0.0164
0.0172
0.0160
0.0168
0.0152
0.0159
0.0148
0.0156
0.0139
0.0146
0.0133
0.0118
0.0106
0.0094
0.0081
0.0072
0.0074

0.0624
0.0477
0.0441
0.0342
0.0296
0.0308
0.0257
0.0268
0.0238
0.0247
0.0216
0.0225
0.0205
0.0213
0.0200
0.0208
0.0190
0.0198
0.0187
0.0194
0.0175
0.0182
0.0168
0.0151
0.0137
0.0123
0.0108
0.0099
0.0101

519
616
646
760
831
814
907
890
955
936
1015
995
1048
1028
1065
1044
1101
1080
1115
1094
1160
1139
1196
1314
1363
1465
1594
1687
1670

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

406
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. A good
strength-to-weight ratio makes ACAR applicable where both ampacity and strength are prime considerations in line design; for equal weight, ACAR offers higher strength and ampacity than ACSR.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TP
Twisted Pair

Construction
TP Conductor is composed of two identical bare conductors twisted together with a left-hand lay.
This gives the cable a rectangular spiral shape. This spiral shape disrupts the forces created by
steady cross winds which cause cable vibration, by presenting a continuously changing projected
cable diameter to the wind. This spiral shape, together with less torsional stiffness and varying
bending stiffness also reduces or eliminates cable galloping due to combined ice and wind loads.
The component conducts of TP can be conductor types AAC, AAAC, ACAR, ACSR, AAC/TW or
ACSR/TW meeting the requirements of the appropriate ASTM standards.
Specifications
TP Conductor meets or exceeds the following ASTM specifications for the subconductor of each assembly:
B-911/B-911M for Twisted Pair Conductor
B-231 Aluminum Conductor, Concentric-Lay Stranded.
B-232 Aluminum Conductor, Concentric-Lay Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
B-524 Concentric-Lay Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR,
1350/6201)
B-779 Shaped Wire Compact Concentric-Lay Stranded Aluminum Conductors, Steel Reinforced
(ACSR/TW.)
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
Current ratings are based on 75C conductor temperature, 25C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item #

Lily TP
Ames TP
Swallow TP
Iris TP
SparrowTP
Pansy TP
Robin TP
Poppy TP
Azuza TP
Raven TP
Aster TP
Anaheim TP
Quail TP
Phlox TP
Amherst TP
Pigeon TP
Oxlip TP
Alliance TP
Penguin TP

Conductor Construction
Type

AAC
AAAC
ACSR
AAC
ACSR
AAC
ACSR
AAC
AAAC
ACSR
AAC
AAAC
ACSR
AAC
AAAC
ACSR
AAC
AAAC
ACSR

2x#3
2x#2
2x#3
2x#2
2x#2
2x#1
2x#1
2x1/0
2x1/0
2x1/0
2x2/0
2x2/0
2x2/0
2x3/0
2x3/0
2x3/0
2x4/0
2x4/0
2x4/0

Total
Kcmil

Stranding
Aluminum

Stranding
Steel

Outer
Dimension
(in)

Equivalent
Diameter
(in)

Weight
/MFT
Alum
(lb)

Weight
/MFT
Steel
(lb)

Weight
/MFT
Total
(lb)

Rated
Breaking
Strength
(lb)

Rating
(amp)

105.2
154.9
105.2
132.7
132.7
167.4
167.4
211.2
246.6
211.2
266.2
310.8
266.2
335.6
391.4
335.6
423.2
493.8
423.2

7x0.0867
7x0.1052
6x0.0937
7x0.0974
6x0.1052
7x0.1093
6x0.1181
7x0.1228
7x0.1327
6x0.1327
7x0.1379
7x0.1490
6x0.1489
7x0.1548
7x0.1672
6x0.1672
7x0.1739
7x0.1878
6x0.1878

N/A
N/A
1x0.0937
N/A
1x0.1052
N/A
1x0.1181
N/A
N/A
1x0.1327
N/A
N/A
1x0.1489
N/A
N/A
1x0.1672
N/A
N/A
1x0.1878

0.260x0.520
0.316x0.632
0.281x0.562
0.292x0.584
0.316x0.631
0.328x0.656
0.355x0.710
0.368x0.736
0.396x0.796
0.396x0.790
0.414x0.828
0.447x0.894
0.447x0.894
0.464x0.926
0.502x1.004
0.502x1.004
0.552x1.044
0.563x1.126
0.563x1.126

0.426
0.517
0.460
0.478
0.517
0.537
0.581
0.602
0.652
0.652
0.678
0.732
0.732
0.760
0.822
0.822
0.854
0.922
0.922

99.0
145.4
98.4
124.6
124.0
157.0
156.4
198.2
231.4
197.2
250.0
291.8
248.6
315.0
367.4
313.4
397.2
463.6
395.4

N/A
N/A
46.4
N/A
59.0
N/A
74.0
N/A
N/A
93.2
N/A
N/A
117.6
N/A
N/A
148.2
N/A
N/A
188.8

99.0
145.4
144.8
124.6
183.0
157.0
230.4
198.2
231.4
290.4
250.0
291.8
366.2
315.0
367.4
462.0
397.2
463.6
582.2

2180
5600
4600
2700
5700
3280
7100
3980
8920
8760
5020
10780
10600
6080
13580
13240
7660
17120
16700

272
328
275
316
316
367
371
426
437
420
495
510
484
574
592
582
667
692
642

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

405
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
TP Twisted Pair Conductor bare aluminum construction, is designed for use in overhead applications subject to Aeolian vibration and galloping due to wind and ice. TP Conductor can be strung to
the maximum allowable tension limits without the need for additional vibration protection.

TRANSMISSION &
DISTRIBUTION CABLES

TP
Twisted Pair
Item #

Jaeger TP
Daisy TP
Butte TP
Waxwing TP
Partridge TP
Tulip TP
Merlin TP
Linnett TP
Canna TP
Chickadee TP
Ptarmigan TP
Ibis TP
Cosmos TP
Pelican TP
Taller TP
Flicker-TP
Hawk TP
Dahila TP
Flycatcher TP
Creeper TP
OspreyTP
Kinglet TP
Parakeet TP
Dove TP
Day Lily TP
Kittiwake TP
Squab TP
Orchid TP
Kingbird TP
Turacos TP
Rook TP
Gloxinia TP
Siskin TP
Flamingo TP
Violet TP
Dunlin TP
Arbutus TP
Tern TP
Drake TP
Cockscomb TP
Surfbird TP
Twinstone TP
Bluebell TP
Marigold TP
Ortolan TP
Bluejay TP

Conductor Construction
Type

ACSR
AAC
AAAC
ACSR
ACSR
AAC
ACSR
ACSR
AAC
ACSR
ACSR
ACSR
AAC
ACSR
ACSR
ACSR
ACSR
AAC
ACSR
ACSR
ACSR
ACSR
ACSR
ACSR
AAC
ACSR
ACSR
AAC
ACSR
ACSR
ACSR
AAC
ACSR
ACSR
AAC
ACSR
AAC
ACSR
ACSR
AAC
ACSR
ACSR
AAC
AAC
ACSR
ACSR

2x228.2
2x266.8
2x266.8
2x266.8
2x266.8
2x336.4
2x336.4
2x336.4
2x397.5
2x397.5
2x397.5
2x397.5
2x477.0
2x447.0
2x477.0
2x477.0
2x477.0
2x556.5
2x516.8
2x516.8
2x556.5
2x556.5
2x556.5
2x556.5
2x596.0
2x596.0
2x605.0
2x636.0
2x636.0
2x636.0
2x636.0
2x666.6
2x666.6
2x666.6
2x715.5
2x715.5
2x795.0
2x795.0
2x795.0
2x900.0
2x874.5
2x900.0
2x1033.5
2x1113.5
2x1033.5
2x1113.0

Total
Kcmil

Stranding
Aluminum

456.4 18x0.1126
533.6
7x0.1953
533.6 19x0.1283
533.6 18x0.1217
533.6 26x0.1013
672.8 19x0.1331
672.8 18x0.1387
672.8 26x0.1137
795.0 19x0.1447
795.0 18x0.1486
795.0 20x0.1400
795.0 26x0.1236
954.0 19x0.1584
954.0 18x0.1628
954.0 20x0.1544
954.0 24x0.1410
954.0 26x0.1354
1113
19x0.1711
1033.5 18x0.1694
1033.5 20x0.1607
1113
18x0.1758
1113
20x0.1667
1113
24x0.1523
1113
26x0.1463
1192
19x0.1771
1192 18x0.1820
1210 20x0.1739
1272 37x0.1311
1272 18x0.1880
1272 20x0.1783
1272 24x0.1626
1333 37x0.1342
1334 20x0.1826
1334 24x0.1667
1431 37x0.1391
1431 20x0.1891
1590 37x0.1466
1590 45x0.1329
1590 26x0.1749
1800 37x0.1580
1749 20x0.2091
1800 20x0.2121
2067 37x0.1671
2226 61x0.1351
2067 45x0.1515
2226 45x0.1573

Stranding
Steel

Outer
Dimension
(in)

1x0.1126 0.536x1.126
N/A
0.586x1.172
N/A
0.642x1.284
1x0.1217 0.609x1.218
7x0.0788 0.642x1.284
N/A
0.666x1.332
1x0.1367 0.684x1.368
7x0.0884 0.721x1.442
N/A
0.724x1.448
1x0.1486 0.743x1.486
7x0.0626 0.752x1.504
7x0.0961 0.783x1.566
N/A
0.793x1.586
1x0.1628 0.814x1.628
7x0.0686 0.823x1.647
7x0.0940 0.846x1.692
7x0.1053 0.858x1.716
N/A
0.856x1.712
1x0.1694 0.847x1.694
7x0.0714 0.857x1.714
1x0.1758 0.879x1.758
7x0.0741 0.889x1.778
7x0.1015 0.914x1.828
7x0.1138 0.927x1.854
N/A
0.886x1.771
1x0.1820 0.910x1.820
7x0.0773 0.928x1.855
N/A
0.918x1.836
1x0.1880 0.940x1.880
7x0.0792 0.951x1.902
7x0.1085 0.977x1.954
N/A
0.939x1.879
7x0.0812 1.974x1.948
7x0.1111 1.000x2.000
N/A
1.974x1.945
7x0.0840 1.005x2.016
N/A
1.026x2.052
7x0.0886 1.064x2.128
7x0.1360 1.108x2.216
N/A
1.092x2.184
7x0.0929 1.115x2.23
7x0.0943 1.131x2.262
N/A
1.170x2.340
N/A
1.216x2.432
7x0.1010 1.212x2.424
7x0.1049 1.258x2.516

Equivalent
Diameter
(in)

Weight
/MFT
Alum
(lb)

Weight
/MFT
Steel
(lb)

Weight
/MFT
Total
(lb)

Rated
Breaking
Strength
(lb)

Rating
(amp)

0.922
0.959
1.051
0.997
1.051
1.090
1.120
1.180
1.185
1.216
1.231
1.282
1.298
1.333
1.347
1.385
1.405
1.401
1.387
1.403
1.439
1.455
1.496
1.518
1.450
1.490
1.518
1.503
1.539
1.557
1.599
1.538
1.594
1.637
1.594
1.650
1.680
1.742
1.814
1.788
1.825
1.851
1.915
1.991
1.984
2.059

428.5
501
587.2
501
504
632
632
634
746
746
747
750
896
896
895
900
900
1045
970
974
1044
1050
1050
1050
1119
1119
1141
1194
1194
1200
1200
1251
1258
1258
1343
1350
1493
1500
1500
1690
1650
1698
1940
2090
1948
2100

67.1
N/A
N/A
78.6
230
N/A
100
292
N/A
118
146
344
N/A
140
175
328
414
N/A
152
190
164
204
384
482
N/A
175
222
N/A
186
234
438
N/A
246
450
N/A
262
N/A
292
688
N/A
322
332
N/A
N/A
380
410

495.6
501
587.2
580
734
632
732
926
746
864
893
1094
896
1036
1070
1228
1314
1045
1122
1164
1208
1254
1434
1532
1119
1294
1383
1194
1380
1434
1638
1251
1504
1718
1343
1612
1493
1792
2188
1690
1972
2030
1940
2090
2328
2510

12200
9700
22000
13800
22600
12300
17400
28200
14200
19900
22200
32600
16700
23600
26400
34400
39000
19500
25500
28300
27400
30500
39600
45200
20400
29800
33200
22800
31400
34800
45400
23800
36600
47600
25600
39200
27800
44200
63000
30800
47600
48200
35400
39400
55400
59600

720
774
810
789
810
902
917
923
984
1001
1007
1030
1108
1128
1134
1153
1162
1224
1188
1194
1247
1254
1275
1290
1279
1304
1324
1335
1359
1368
1391
1375
1410
1434
1439
1474
1536
1577
1620
1658
1674
1703
1801
1882
1853
1939

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
405
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ASCR/TW

SPECIFICATIONS
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel
Reinforced (ACSR)
B-779 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced
(ACSR/TW).
CONSTRUCTION
Aluminum alloy 1350-H19 trapezoidal shaped wires, concentrically stranded about a steel core. Core
wire for ACSR/TW is available with class A, B, or C galvanizing; aluminized aluminum coated (AZ);
or aluminum-clad (AW1). Additional corrosion protection is available through the application of
grease to the core or infusion of the complete cable with grease.
NOTES
* Ampacity calculated assuming: ambient 250C, conductor 75C, wind 2 ft./sec., sun.

Item #

Merlin/TW
Flicker/TW
Hawk/TW
Parakeet/TW
Dove/TW
Swift/TW
Rook/TW
Grosbeak/TW
Tern/TW
Puffin/TW
Condor/TW
Drake/TW
Phoenix/TW
Rail/TW
Cardinal/TW
Snowbird/TW
Ortolan/TW
Curlew/TW
Avocet/TW
Bluejay/TW
Finch/TW
Oxbird/TW
Bunting/TW

Conductor
Conductor
Type
Stranding
Size
Area
Area Code No. Al
St
Al
Total
Layers
(sq.in) (sq.in)
of Al
336.4
477.0
477.0
556.5
556.5
636.0
636.0
636.0
795.0
795.0
795.0
795.0
954.0
954.0
954.0
1033.5
1033.5
1033.5
1113.0
1113.0
1113.0
1192.5
1192.5

0.2642
0.3747
0.3746
0.4371
0.4371
0.4995
0.4995
0.4995
0.6244
0.6244
0.6244
0.6244
0.7493
0.7493
0.7493
0.8117
0.8117
0.8117
0.8742
0.8742
0.8742
0.9366
0.9366

0.2788
0.4233
0.4356
0.4937
0.5083
0.5133
0.5643
0.5808
0.6675
0.6919
0.7053
0.7261
0.7876
0.8011
0.8464
0.8534
0.8678
0.9169
0.9191
0.9347
0.9851
0.9848
1.0013

6
13
16
13
16
3
13
16
7
10
13
16
5
7
13
5
7
13
5
7
13
5
7

2
2
2
2
2
3
2
2
2
2
2
2
3
3
2
3
3
2
3
3
3
2
3

14
18
18
18
20
27
19
20
17
18
20
20
30
32
20
30
32
20
30
33
38
30
34

1x0.1367
7x0.0940
7x0.1053
7x0.1015
7x0.1138
1x0.1329
7x0.1085
7x0.1216
7x0.0886
7x0.1108
7x0.1203
7x0.1360
7x0.0837
7x0.0971
7x0.1329
7x0.0871
7x0.1010
7x0.1383
7x0.0904
7x0.1049
19x0.0862
7x0.0936
7x0.1085

Outside Diameter
Weight
Rated
Resistance
Allowable
Complete Steel
Total Aluminum Steel Strength DC@20C AC@75C Ampacities
Conductor Core (lb/MFT) (lb/MFT) (lb/MFT)
(lb)
(OMS/ (OMS/
*
(in)
(in)
MFT)
MFT)
0.630
0.776
0.789
0.835
0.852
0.850
0.890
0.908
0.960
0.980
0.993
1.010
1.044
1.061
1.084
1.089
1.102
1.129
1.129
1.143
1.185
1.167
1.181

0.1367
0.2820
0.3159
0.3045
0.3414
0.1329
0.3255
0.3648
0.2658
0.3324
0.3639
0.4080
0.2511
0.2913
0.3987
0.2613
0.3030
0.4149
0.2712
0.3147
0.4310
0.2808
0.3255

365.0
612.8
655.0
714.9
764.5
646.0
816.0
873.5
892.0
975.3
1021.0
1092.0
1032.0
1075.0
1226.0
1115.0
1165.0
1327.0
1201.0
1257.0
1429.0
1286.0
1343.0

315.5
448.4
448.7
523.2
523.5
599.2
597.9
598.4
745.9
746.9
747.2
747.8
901.6
900.0
897.3
973.8
975.2
971.1
1048.9
1052.2
1052.6
1123.0
1124.0

49.5
164.4
206.3
191.7
241.0
46.8
219.1
275.1
146.1
228.4
273.8
344.2
130.4
175.0
328.7
141.2
189.8
355.9
152.1
204.8
376.4
163.0
219.0

8560
17200
19400
20000
22600
13500
22900
25400
21000
25900
28200
31800
23700
25900
33500
25700
28100
36300
27500
30300
39100
29500
32400

0.0510
0.0357
0.0356
0.0306
0.0305
0.0272
0.0268
0.0267
0.0215
0.0215
0.0214
0.0213
0.0181
0.0180
0.0178
0.0167
0.0167
0.0165
0.0155
0.0155
0.0154
0.0144
0.0144

0.0625
0.0437
0.0435
0.0375
0.0374
0.0335
0.0329
0.0327
0.0266
0.0264
0.0264
0.0263
0.0224
0.0224
0.0221
0.0208
0.0207
0.0204
0.0193
0.0193
0.0191
0.0180
0.0181

508
641
645
706
711
750
766
772
869
876
880
887
967
973
985
1017
1021
1036
1063
1069
1084
1111
1114

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

419
20160520

TRANSMISSION.&
DISTRIBUTION CABLES

APPLICATION
Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductor, Steel-Reinforced (ACSR/TW)
is designed for use as a bare overhead conductor. There are two designs of ACSR/TW. One design
gives an equal area of aluminum when compared to the standard ACSR conductor sizes. The other
design gives an overall outside diameter equal to standard ACSR conductor sizes. Use of this conductor in the equal area design allows equal ampacity in a smaller diameter conductor when compared with standard ACSR conductor. Use of this conductor in the equal diameter design allows
more ampacity in an equal diameter conductor when compared with standard ACSR conductor.

TRANSMISSION &
DISTRIBUTION CABLES

ASCR/TW
Item #

Conductor
Conductor
Type
Stranding
Size
Area
Area Code No. Al
St
Al
Total
Layers
(sq.in) (sq.in)
of Al

Grackel/TW
1192.5
Scissortail/TW 1272.0
Bittern/TW
1272.0
Pheasant/TW 1272.0
Dipper/TW
1351.0
Martin/TW
1351.0
Bobolink/TW
1431.0
Plover/TW
1431.0
Lapwing/TW
1590.0
Falcon/TW
1590.0
Chukar/TW
1780.0
Bluebird/TW
2156.0
Monongahela/TW 405.1
Mohawk/TW
571.7
Calumet/TW
565.3
Mystic/TW
666.6
Oswego/TW
664.8
Nechako/TW
768.9
Maumee/TW
768.2
Wabash/TW
762.8
Kettle/TW
957.2
Fraser/TW
946.7
Columbia/TW
966.2
Suwannee/TW 959.6
Cheyenne/TW 1168.1
Genesee/TW 1158.0
Hudson/TW
1158.4
Catawba/TW 1272.0
Nelson/TW
1257.1
Yukon/TW
1233.6
Truckee/TW
1372.5
Mackenzie/TW 1359.7
Thames/TW
1334.6
St. Croix/TW
1467.8
Miramichi/TW 1455.3
Merrimack/TW 1433.6
Platte/TW
1569.0
Potomac/TW 1557.4
Rio Grande/TW 1533.3
Schuylkill/TW 1657.4
Pecos/TW
1622.0
Pee Dee/TW
1758.6
James/TW
1730.6
Athabaska/TW 1949.6
Cumberland/TW 1926.9
Powder/TW
2153.8
Santee/TW
2627.3

0.9366
0.9991
0.9990
0.9990
1.0615
1.0615
1.1236
1.1239
1.2488
1.2488
1.3986
1.0934
0.3181
0.4490
0.4439
0.5236
0.5221
0.6039
0.6034
0.5992
0.7518
0.7436
0.7589
0.7537
0.9175
0.9095
0.9098
0.9991
0.9874
0.9689
1.0780
1.0679
1.3480
1.1529
1.1430
1.1250
1.2323
1.2232
1.2043
1.3020
1.2739
1.3810
1.3590
1.5312
1.5134
1.6912
2.0630

1.0554
1.0505
1.0681
1.1256
1.1348
1.1959
1.2017
1.2664
1.3351
1.4071
1.5120
1.8312
0.3362
0.5074
0.5165
0.5914
0.6072
0.6220
0.6819
0.6966
0.8038
0.8168
0.8573
0.8762
0.9646
0.9733
1.0281
1.0505
1.0557
1.0925
1.1334
1.1418
1.1809
1.2124
1.2222
1.2677
1.2957
1.3079
1.3571
1.3920
1.4429
1.4770
1.5314
1.6377
1.7049
1.8290
2.2268

13
5
7
13
7
13
7
13
7
13
8
8
6
13
16
13
16
3
13
16
7
10
13
16
5
7
13
5
7
13
5
7
13
5
7
13
5
7
13
7
13
7
13
7
13
8
8

3
3
3
3
3
3
3
3
3
3
3
4
2
2
2
2
2
3
2
2
3
3
2
2
3
3
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4

38
30
35
39
35
42
36
44
36
42
37
64
14
18
18
20
20
27
20
20
32
35
21
22
30
33
26
30
35
38
30
36
39
33
36
39
33
36
39
36
39
37
34
44
42
64
64

19x0.0892
7x0.0967
7x0.1121
19x0.9210
7x0.1155
19x0.0949
7x0.1189
19x0.0977
7x0.1253
19x0.1030
19x0.0874
19x0.0961
1x0.1520
7x0.1030
7x0.1147
7x0.1111
7x0.1244
1x0.1520
7x0.1195
7x0.1331
7x0.0973
7x0.1154
7x0.1338
7x0.1493
7x0.0926
7x0.1078
7x0.1467
7x0.0967
7x0.1115
19x0.0910
7x0.1004
7x0.1559
19x0.0944
7x0.1041
7x0.1200
19x0.0978
7x0.1074
7x0.1241
19x0.1012
7x0.128
19x0.1064
7x0.1319
19x0.1075
7x0.1392
19x0.1133
19x0.0961
19x0.1062

Outside Diameter
Weight
Rated
Resistance
Allowable
Complete Steel
Total Aluminum Steel Strength DC@20C AC@75C Ampacities
Conductor Core (lb/MFT) (lb/MFT) (lb/MFT)
(lb)
(OMS/ (OMS/
*
(in)
(in)
MFT)
MFT)
1.225
1.203
1.220
1.264
1.256
1.300
1.291
1.337
1.358
1.408
1.445
1.608
0.680
0.846
0.858
0.913
0.927
0.930
0.977
0.990
1.060
1.077
1.092
1.108
1.155
1.165
1.196
1.203
1.213
1.245
1.248
1.259
1.290
1.292
1.302
1.340
1.334
1.345
1.382
1.386
1.424
1.427
1.470
1.504
1.545
1.602
1.762

0.4460
0.2901
0.3363
0.4605
0.3465
0.4745
0.3567
0.4885
0.3759
0.5150
0.4370
0.4805
0.1520
0.3090
0.3438
0.3330
0.3732
0.1520
0.3585
0.3993
0.2919
0.3462
0.4014
0.4479
0.2778
0.3234
0.4401
0.2901
0.3345
0.4550
0.3012
0.3477
0.4720
0.3123
0.3600
0.4890
0.3222
0.3723
0.5060
0.3840
0.5320
0.3957
0.5375
0.4176
0.5665
0.4805
0.5310

1530.0
1372.0
1433.0
1632.0
1522.0
1734.0
1613.0
1836.0
1791.0
2040.0
2063.0
2515.0
441.0
734.7
714.8
856.3
913.4
781.9
987.8
1047.0
1079.0
1142.0
1241.0
1318.0
1260.0
1308.0
1489.0
1372.0
1417.0
1586.0
1481.0
1530.0
1713.0
1585.0
1640.0
1840.0
1693.0
1755.0
1968.0
1868.0
2107.0
1982.0
2221.0
2199.0
2471.0
2498.0
3048.0

1127.0
1198.0
1198.0
1202.0
1274.0
1278.0
1350.0
1353.0
1499.0
1503.0
1676.0
2047.0
379.8
537.3
523.1
626.6
625.4
720.7
722.1
717.0
902.8
894.0
908.0
903.0
1100.4
1092.0
1089.0
1198.0
1185.7
1166.5
1293.4
1280.0
1261.6
1383.0
1372.0
1356.0
1478.0
1468.0
1449.0
1563.0
1533.0
1658.0
1636.0
1838.0
1821.0
2030.0
2477.0

403.0
174.0
234.0
430.0
248.0
456.0
263.0
483.0
292.0
537.0
387.0
468.0
61.2
197.4
191.7
229.7
288.0
61.2
265.7
330.0
176.2
248.0
333.0
415.0
159.6
216.0
400.0
174.0
231.3
419.5
187.6
250.0
451.4
202.0
268.0
434.0
215.0
287.0
519.0
305.0
574.0
324.0
585.0
361.0
650.0
468.0
571.0

41900
31400
34600
44100
36700
46800
38900
49600
42200
55100
50700
61100
10200
20700
22900
24000
26600
16400
27700
30500
26000
29600
34000
37000
28900
31600
39600
31400
34200
42900
33400
36900
46300
35800
39200
49700
38200
41900
53200
44000
57500
46700
59400
51900
65300
61100
74500

0.0144
0.0135
0.0135
0.0135
0.0127
0.0127
0.0120
0.0120
0.0183
0.0108
0.0096
0.0080
0.0423
0.0298
0.0300
0.0255
0.0255
0.0255
0.0222
0.0222
0.0180
0.0180
0.0176
0.0177
0.0148
0.0149
0.0147
0.0135
0.0137
0.0139
0.0126
0.0127
0.0128
0.0117
0.0118
0.0119
0.0110
0.0111
0.0112
0.0104
0.0106
0.0098
0.0099
0.0088
0.0089
0.0080
0.0066

0.0179
0.0170
0.0170
0.0168
0.0160
0.0159
0.0152
0.0150
0.0138
0.0136
0.0124
0.0105
0.0519
0.0365
0.0368
0.0314
0.0313
0.0278
0.0273
0.0274
0.0223
0.0223
0.0218
0.0218
0.0185
0.0186
0.0183
0.0170
0.0172
0.0173
0.0159
0.0159
0.0160
0.0149
0.0150
0.0150
0.0140
0.0140
0.0141
0.0133
0.0133
0.0126
0.0126
0.0115
0.0114
0.0105
0.0089

1130
1152
1159
1176
1202
1219
1243
1262
1323
1345
1420
1586
569
718
718
790
794
843
862
863
974
978
993
996
1095
1095
1111
1152
1150
1154
1206
1206
1210
1256
1256
1264
1306
1307
1316
1356
1363
1404
1415
1491
1507
1584
1768

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
419
20160520

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSS/TW

CONSTRUCTION
ACSS is a composite concentric-lay-stranded conductor. Steel strands form the central core of the
conductor with one or more layers of 63% minimum average conductivity aluminum 1350-0 wire
stranded around it. The steel core carries most or all of the mechanical load of the conductor due to
the "0" (fully annealed or soft) temper aluminum. Steel core wires are protected from corrosion by a
zinc-5% aluminum-mischmetal alloy coating. High strength steel core, aluminized, and aluminum
clad steel core is also available.
SPECIFICATIONS
B500 Metallic Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced.
B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors,
Steel Reinforced.
B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum
and Aluminum-Alloy Conductors, Steel Reinforced.
B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS)
B857 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW).
NOTES
1)Data based on a nominal cable manufactured in accordance with ASTM B 857.
2)Resistance and ampacity based on an aluminum conductivity of 63% IACS at 20C and a steel
conductivity of 8% IACS at 20C.
3)Ampacity based on referenced conductor temperature, 25C ambient temperature, 2 ft/sec wind,
in sun, with an emmisivity of 0.5 and a coefficient of solar absorption of 0.5, at sea level.
4)Rated breaking strength for standard core based on Class A zinc-5% aluminum-mischmetal alloy
coated steel core wire in accordance with ASTM B 802.
5)Rated strength for high strength core based on Class A zinc-5% aluminum-mischmetal alloy
coated high strength steel core wire in accordance with ASTM B 803.
6)The final design of a shaped wire compact conductor is contingent upon several factors such as:
layer diameter, wire width and wire thickness. The actual configuration of a given size may vary
between manufacturers. This may result in a slight variation in the number of wires, number of
layers and dimensions of individual wires from that shown in the chart.

Item #

Linnet/ACSS/TW
Oriole/ACSS/TW
Flicker/ACSS/TW
Hawk/ACSS/TW
Hen/ACSS/TW
Parakeet/ACSS/TW
Dove/ACSS/TW

Size Type
KCMIL No.

336.4
336.4
477.0
477.0
477.0
556.5
556.5

16
23
13
16
23
13
16

Cross
Stranding
Sectional
Al/Total Layers No. x Dia./
(in)2
Wires St Wire
0.2641/0.3070 2 18 7 x 0.0884
0.2642/0.3258 2 16 7 x 0.1059
0.3747/0.4233 2 18 7 x 0.0940
0.3746/0.4356 2 18 7 x 0.1053
0.3747/0.4621 2 16 7 x 0.1261
0.4371/0.4937 2 18 7 x 0.1015
0.4371/0.5083 2 20 7 x 0.1138

Diameter
Weight
Rated Breaking
(in)
(lb/MFT)
Strength (lb)
St Complete Al
St
Total Standard High Ultra
Core Cable
High
0.2652 0.659 315.9 145.5 461.4 11200 12300 14400
0.3177 0.693 316.1 208.7 524.8 14800 16300 19100
0.2820 0.776 447.8 164.5 612.3 13000 14200 16400
0.3159 0.789 448.1 206.4 654.5 15600 17100 19800
0.3783 0.825 448.3 296.0 744.3 21000 22700 26700
0.3045 0.835 522.4 191.8 714.2 15200 16600 19100
0.3414 0.852 522.9 241.0 763.9 18200 19900 23100

Resistance
(ohm/mile)
DC
AC
20C
75C
0.2588 0.3181
0.2565 0.3151
0.1831 0.2255
0.1825 0.2247
0.1809 0.2225
0.1569 0.1935
0.1564 0.1928

Ampacity
(amps)
75C 100C 150C 200C 250C
523
533
648
652
663
713
719

638
650
793
799
813
874
881

801
816
998
1005
1024
1102
1111

921
940
1151
1159
1181
1271
1282

1021
1043
1279
1289
1315
1415
1427

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

418
20140925

TRANSMISSION.&
DISTRIBUTION CABLES

APPLICATIONS
ACSS/TW is designed for overhead distribution and transmission lines. It is designed to operate
continuously at elevated temperatures up to 250C without loss of strength, it sags less under emergency electrical loadings than ACSR/TW, excellent self-damping properties, and its final sags are
not affected by long-term creep of aluminum. ACSS/TW is available in equal area and equal diameter design. The equal area design allows equal ampacity in a smaller diameter conductor when
compared with a standard ACSS conductor. The equal diameter design allows more ampacity in an
equal diameter conductor when compared with a standard ACSS conductor. ACSS/TW also provides many design opportunities for new line construction: i.e., reduced tower cost, decreased sag,
increased self-damping properties, increased operating temperature and improved corrosion resistance.

TRANSMISSION &
DISTRIBUTION CABLES

ACSS/TW
Item #

Size Type
KCMIL No.

Rook/ACSS/TW
Grosbeak/ACSS/TW
Scoter/ACSS/TW
Tern/ACSS/TW
Puffin/ACSS/TW
Condor/ACSS/TW
Drake/ACSS/TW
Canary/ACSS/TW
Phoenix/ACSS/TW
Rail/ACSS/TW
Cardinal/ACSS/TW
Snowbird/ACSS/TW
Ortolan/ACSS/TW
Curlew/ACSS/TW
Avocet/ACSS/TW
Bluejay/ACSS/TW
Finch/ACSS/TW
Oxbird/ACSS/TW
Bunting/ACSS/TW
Grackle/ACSS/TW
Scissortail/ACSS/TW
Bittern/ACSS/TW
Pheasant/ACSS/TW
Dipper/ACSS/TW
Martin/ACSS/TW
Bobolink/ACSS/TW
Plover/ACSS/TW
Lapwing/ACSS/TW
Falcon/ACSS/TW
Chukar/ACSS/TW
Bluebird/ACSS/TW
Mohawk/ACSS/TW
Calumet/ACSS/TW
Mystic/ACSS/TW
Oswego/ACSS/TW
Maumee/ACSS/TW
Wabash/ACSS/TW
Kettle/ACSS/TW
Fraser/ACSS/TW
Columbia/ACSS/TW
Suwannee/ACSS/TW
Cheyenne/ACSS/TW
Genesee/ACSS/TW
Hudson/ACSS/TW
Catawba/ACSS/TW
Nelson/ACSS/TW
Yukon/ACSS/TW

636.0
636.0
636.0
795.0
795.0
795.0
795.0
900.0
954.0
954.0
954.0
1033.5
1033.5
1033.5
1113.0
1113.0
1113.0
1192.5
1192.5
1192.5
1272.0
1272.0
1272.0
1351.5
1351.5
1431.0
1431.0
1590.0
1590.0
1780.0
2156.0
571.7
565.3
666.6
664.8
768.2
762.8
957.2
946.7
966.2
959.6
1168.1
1158.0
1158.4
1272.0
1257.1
1233.6

13
16
23
7
11
13
16
13
5
7
13
5
7
13
5
7
13
5
7
13
5
7
13
7
13
7
13
7
13
8
8
13
16
13
16
13
16
7
10
13
16
5
7
13
5
7
13

Cross
Stranding
Sectional
Al/Total Layers No. x Dia./
(in)2
Wires St Wire
0.4995/0.5643
0.4995/0.5808
0.4995/0.6160
0.6244/0.6675
0.6244/0.6919
0.6244/0.7053
0.6244/0.7261
0.7069/0.7983
0.7493/0.7876
0.7493/0.8011
0.7493/0.8464
0.8117/0.8534
0.8117/0.8678
0.8117/0.9169
0.8742/0.9191
0.8742/0.9347
0.8743/0.9852
0.9366/0.9848
0.9366/1.0013
0.9366/1.0554
0.9991/1.0505
0.9990/1.0681
0.9990/1.1256
1.0615/1.1348
1.0615/1.1959
1.1236/1.2017
1.1239/1.2664
1.2488/1.3351
1.2488/1.4071
1.3986/1.5126
1.6933/1.8309
0.4490/0.5074
0.4439/0.5162
0.5236/0.5914
0.5221/0.6072
0.6034/0.6819
0.5992/0.6966
0.7518/0.8038
0.7436/0.8168
0.7589/0.8573
0.7537/0.8762
0.9175/0.9646
0.9095/0.9733
0.9098/1.0281
0.9991/1.0505
0.9874/1.0557
0.9689/1.0925

2
2
2
2
2
2
2
2
3
3
2
3
3
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
2
2
2
2
2
2
3
3
2
2
3
3
2
3
3
3

18
20
18
17
18
20
20
20
30
32
20
30
32
20
30
33
38
30
34
38
30
35
39
35
42
36
44
36
42
37
64
18
20
20
20
20
20
32
35
21
22
30
33
25
30
35
38

7 x 0.1085
7 x 0.1216
7 x 0.1456
7 x 0.0886
7 x 0.1056
7 x 0.1213
7 x 0.1360
7 x 0.1291
7 x 0.0837
7 x 0.0971
7 x 0.1329
7 x 0.0871
7 x 0.1010
7 x 0.1383
7 x 0.0904
7 x 0.1049
19 x 0.0862
7 x 0.0936
7 x 0.1085
19 x 0.0892
7 x 0.0967
7 x 0.1121
19 x 0.0921
7 x 0.1155
19 x 0.0949
7 x 0.1189
19 x 0.0977
7 x 0.1253
19 x 0.1030
19 x 0.0874
19 x 0.0961
7 x 0.1030
7 x 0.1146
7 x 0.1111
7 x 0.1244
7 x 0.1195
7 x 0.1331
7 x 0.0973
7 x 0.1154
7 x 0.1338
7 x 0.1493
7 x 0.0926
7 x 0.1078
7 x 0.1467
7 x 0.0967
7 x 0.1115
19 x 0.0910

Diameter
Weight
Rated Breaking
(in)
(lb/MFT)
Strength (lb)
St Complete Al
St
Total Standard High Ultra
Core Cable
High
0.3255
0.3648
0.4368
0.2658
0.3168
0.3639
0.4080
0.3873
0.2511
0.2913
0.3987
0.2613
0.3030
0.4149
0.2712
0.3147
0.4310
0.2808
0.3255
0.4460
0.2901
0.3363
0.4605
0.3465
0.4745
0.3567
0.4885
0.3759
0.5150
0.4370
0.4805
0.3090
0.3441
0.3333
0.3732
0.3585
0.3993
0.2919
0.3462
0.4014
0.4479
0.2778
0.3234
0.4401
0.2901
0.3345
0.4550

0.890
0.908
0.953
0.960
0.980
0.993
1.010
1.055
1.044
1.061
1.084
1.089
1.102
1.129
1.129
1.143
1.185
1.167
1.181
1.225
1.203
1.220
1.264
1.256
1.300
1.291
1.337
1.358
1.408
1.445
1.608
0.846
0.858
0.913
0.927
0.977
0.990
1.060
1.077
1.092
1.108
1.155
1.165
1.196
1.203
1.213
1.245

597.0
597.6
597.6
745.2
745.9
746.3
747.0
844.9
897.7
898.6
895.5
972.5
972.5
970.1
1047
1048
1051
1122
1123
1126
1197
1198
1201
1273
1276
1347
1351
1498
1501
1675
2045
536.6
531.2
625.7
624.6
721.1
716.7
901.6
892.6
906.9
901.6
1099
1091
1087
1197
1184
1165

219.1
275.2
394.6
146.1
228.5
273.9
344.3
310.2
130.4
175.5
328.7
141.2
189.9
356.0
152.1
204.8
376.1
163.1
219.1
402.8
174
233.9
429.4
248.3
455.9
263.1
483.2
292.2
537
386.7
467.5
197.5
244.4
229.7
288.0
265.8
329.7
176.2
247.9
333.2
414.9
159.6
216.3
400.6
174.0
231.4
419.2

816.1
872.8
992.2
891.3
974.4
1020
1091
1155
1028
1074
1224
1114
1162
1326
1199
1253
1427
1285
1342
1529
1371
1432
1630
1521
1732
1611
1834
1790
2038
2062
2512
734.1
775.6
855.4
912.6
986.9
1046
1078
1141
1240
1317
1259
1307
1488
1371
1415
1584

17300
20700
27400
14200
17700
21700
25900
24600
14200
16700
26000
15400
18100
28200
16300
19500
30400
17500
20900
32600
18700
22300
34100
23700
36200
25100
38400
27900
42600
35300
42100
15600
18400
18200
21700
21000
24900
16800
21100
26400
30700
17200
20500
31100
18700
22100
33200

19000
22400
29700
15200
19200
23300
28000
26400
15200
18000
28000
16400
19500
30300
17500
21000
33200
18700
22500
35500
20000
24000
37300
25500
39600
27000
41900
29600
46600
38200
45500
17100
20200
19900
23400
23000
26800
18100
22900
28300
33100
18300
22100
33500
20000
23800
36300

Resistance
(ohm/mile)
DC
AC
20C
75C

21900
26000
35000
17400
22000
26900
32600
30500
17100
20400
32300
18500
22000
35000
19500
23800
38700
20900
25400
41500
22300
27100
43000
28800
45600
30500
48300
33500
53700
43900
51700
19700
23500
22900
27200
26500
31200
20400
26200
32800
38600
20500
25000
38800
22300
26900
41900

0.1373
0.1369
0.1356
0.1105
0.1101
0.1098
0.1095
0.0970
0.0927
0.0926
0.0915
0.0856
0.0854
0.0845
0.0794
0.0793
0.0789
0.0741
0.0740
0.0737
0.0695
0.0694
0.0691
0.0653
0.0650
0.0617
0.0614
0.0555
0.0553
0.0495
0.0412
0.1527
0.1540
0.1310
0.1309
0.1137
0.1141
0.0922
0.0930
0.0904
0.0907
0.0757
0.0762
0.0754
0.0695
0.0702
0.0712

0.1696
0.1689
0.1672
0.1373
0.1365
0.1361
0.1355
0.1205
0.1187
0.1183
0.1138
0.1098
0.1095
0.1053
0.1022
0.1019
0.1010
0.0957
0.0954
0.0944
0.0900
0.0897
0.0887
0.0847
0.0837
0.0802
0.0793
0.0727
0.0717
0.0652
0.0543
0.1884
0.1898
0.1619
0.1616
0.1407
0.1411
0.1180
0.1187
0.1124
0.1127
0.0979
0.0981
0.0943
0.0900
0.0907
0.0914

Ampacity
(amps)
75C 100C 150C 200C 250C
775
781
795
878
886
890
896
962
967
972
997
1016
1021
1048
1063
1068
1084
1108
1114
1130
1152
1159
1176
1202
1220
1243
1263
1324
1346
1421
1601
725
725
798
802
872
873
973
974
1005
1008
1095
1094
1124
1152
1150
1154

951
958
976
1080
1090
1095
1103
1185
1189
1196
1229
1251
1257
1293
1310
1317
1336
1367
1374
1395
1423
1431
1452
1485
1508
1538
1562
1640
1668
1764
1999
889
890
980
985
1072
1074
1197
1199
1239
1243
1350
1350
1389
1423
1420
1425

1200
1210
1234
1366
1378
1386
1396
1501
1503
1512
1558
1584
1592
1641
1661
1669
1695
1735
1744
1771
1807
1817
1846
1888
1918
1958
1989
2092
2127
2255
2573
1121
1122
1238
1244
1356
1359
1514
1517
1571
1576
1712
1712
1766
1807
1804
1810

1386
1398
1427
1580
1595
1604
1616
1739
1740
1750
1806
1834
1843
1903
1925
1935
1965
2013
2023
2055
2098
2110
2143
2194
2228
2276
2313
2435
2477
2630
3014
1294
1295
1431
1439
1569
1573
1753
1756
1822
1828
1986
1985
2051
2098
2094
2101

1544
1557
1591
1762
1778
1789
1803
1942
1940
1953
2016
2048
2058
2126
2150
2161
2196
2249
2261
2298
2346
2360
2398
2455
2494
2549
2590
2730
2777
2952
3396
1441
1442
1595
1604
1750
1755
1955
1959
2035
2042
2219
2218
2295
2346
2342
2350

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
418
20140925

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSS/TW
Size Type
KCMIL No.

Truckee/ACSS/TW 1372.5
Mackenzie/ACSS/TW 1359.7
Thames/ACSS/TW 1334.6
St. Croix/ACSS/TW 1467.8
Miramichi/ACSS/TW 1455.3
Merrimack/ACSS/TW 1433.6
Platte/ACSS/TW
1569.0
Potomac/ACSS/TW 1557.4
Rio Grande/ACSS/TW 1533.3
Schuylkill/ACSS/TW 1657.4
Pecos/ACSS/TW
1622.0
Pee Dee/ACSS/TW 1758.6
James/ACSS/TW
1730.6
Athabaska/ACSS/TW 1949.6
Cumberland/ACSS/TW 1926.9
Powder/ACSS/TW 2153.8
Santee/ACSS/TW
2627.3

5
7
13
5
7
13
5
7
13
7
13
7
13
7
13
8
8

Cross
Stranding
Sectional
Al/Total Layers No. x Dia./
(in)2
Wires St Wire
1.0780/1.1334
1.0679/1.1418
1.0480/1.1809
1.1529/1.2124
1.1430/1.2222
1.1250/1.2677
1.2323/1.2957
1.2232/1.3079
1.2043/1.3571
1.3020/1.3920
1.2739/1.4429
1.3810/1.4770
1.3590/1.5314
1.5312/1.6377
1.5134/1.7049
1.6912/1.8290
2.0630/2.2268

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4

30
36
39
33
36
39
33
36
39
36
39
37
34
44
42
64
64

7 x 0.1004
7 x 0.1159
19 x 0.0944
7 x 0.1041
7 x 0.1200
19 x 0.0978
7 x 0.1074
7 x 0.1241
19 x 0.1012
7 x 0.1280
19 x 0.1064
7 x 0.1319
19 x 0.1075
7 x 0.1392
19 x 0.1133
19 x 0.0961
19 x 0.1062

Diameter
Weight
Rated Breaking
(in)
(lb/MFT)
Strength (lb)
St Complete Al
St
Total Standard High Ultra
Core Cable
High
0.3012
0.3477
0.4720
0.3123
0.3600
0.4890
0.3222
0.3723
0.5060
0.3840
0.5320
0.3957
0.5375
0.4176
0.5665
0.4805
0.5310

1.248
1.259
1.290
1.292
1.302
1.340
1.334
1.345
1.382
1.386
1.424
1.427
1.470
1.504
1.545
1.602
1.762

1292
1281
1260
1381
1372
1356
1478
1468
1449
1563
1533
1658
1636
1836
1819
2043
2492

187.6
250.0
451.1
201.7
268.0
434.0
215.0
287.0
519.0
305.0
574.0
324.0
585.0
360.7
649.8
467.5
570.9

1479
1531
1711
1583
1640
1840
1693
1755
1968
1868
2107
1982
2221
2197
2469
2510
3062

20200
23900
35800
21600
25600
38400
23100
27300
41200
29100
45000
30900
46400
34300
51600
42100
51300

21500
25700
39100
23100
27100
42000
24600
29000
45000
30900
49300
32800
50800
36500
56400
45500
55600

Resistance
(ohm/mile)
DC
AC
20C
75C

24000
29000
45100
25800
30700
48400
27500
32800
51900
34900
56900
37100
58500
41300
65000
51700
63100

0.0644
0.0649
0.0658
0.0602
0.0607
0.0613
0.0564
0.0567
0.0573
0.0533
0.0541
0.0502
0.0508
0.0453
0.0456
0.0412
0.0338

0.0838
0.0842
0.0847
0.0787
0.0790
0.0791
0.0740
0.0741
0.0742
0.0700
0.0703
0.0663
0.0663
0.0595
0.0600
0.0543
0.0459

Ampacity
(amps)
75C 100C 150C 200C 250C
1206
1206
1210
1256
1269
1277
1319
1321
1329
1370
1377
1418
1430
1505
1508
1599
1784

1491
1490
1495
1554
1573
1584
1637
1639
1650
1702
1710
1763
1778
1873
1875
1996
2237

1896
1895
1902
1979
2007
2021
2092
2094
2108
2177
2187
2259
2277
2403
2400
2569
2894

2203
2202
2209
2302
2338
2354
2439
2441
2456
2539
2551
2637
2657
2808
2802
3009
3403

2466
2465
2472
2578
2577
2595
2692
2694
2710
2805
2816
2916
2937
3157
3148
3391
3846

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

418
20140925

TRANSMISSION.&
DISTRIBUTION CABLES

Item #

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Solid Soft-Drawn
Bare Aluminum Tie Wire
TRANSMISSION.&
DISTRIBUTION CABLES

Application
To secure conductor to pin type insulators on a distribution line.
Construction
Bare aluminum EC grade solid conductor
Standards
ASTM B-230 Aluminum 1350-H19 Wire for electrical purposes
Packaging
25lb coil, 50lb coil, coil boxes, spool or as required

Item #

ATW-6
ATW-4
ATW-2

Size

Weight
/MFT
(lb)

6
4
2

24.2
38.2
61.1

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

408
20140110

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Covered AL Line Wire


Weatherproof

Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded
and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked
polyethylene (XLP).
Standards
ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
ASTM B-1248 Polyethylene Plastics Molding and Extrusion Materials.
ASTM C-8.35 Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
ICEA S-70-547
Notes
The code words as given apply to conventional polyethylene line wire.
For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum
equivalent.
Ampacity ratings based on 75C conductor temperature, 25C ambient temperature elevation
sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375CCm2/Watt-CM. Wind speed 2ft/sec in sun.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

Item #

AAC
Apple
Pear
Apricot
Peach
Quince
Orange
Fig
Olive
Pomegranate
Mulberry
Anona
Molles
Huckleberry
Paw Paw
Breadfruit
Persimmon
Grapefruit

Size
AWG or
MCM

Strand

Insulation
Thickness
(mil)

Outside
Diameter
(in)

Rated
Breaking
Strength
(lb)

XLP
Weight
/MFT
(lb)

Poly
Weight
/MFT
(lb)

XLP
Ampacity

6
4
4
2
1/0
2/0
3/0
4/0
4/0
266.8
336.4
397.5
477.0
556.5
636.0
795.0
1033.5

Solid
Solid
7/w
7/w
7/w
7/w
7/w
7/w
19/w
19/w
19/w
19/w
37/w
37/w
61/w
61/w
61/w

30
30
30
45
60
60
60
60
60
60
60
75
75
75
95
95
95

.222
.264
.285
.373
.477
.522
.570
.626
.632
.692
.766
.852
.921
.982
1.080
1.187
1.327

445
675
790
1220
1790
2260
2740
3450
3620
4470
5535
6400
7820
8950
10510
12900
16500

33.0
48.5
51.5
87.1
140.7
171.9
210.5
258.7
254.8
313.5
387.6
469.2
550.0
633.0
742.6
910.0
1156.7

32.0
47.3
50.8
84.0
135.6
166.2
204.0
251.4
247.9
305.8
378.8
457.4
537.5
619.4
724.7
890.0
1133.8

105
135
140
180
240
280
320
370
370
430
495
545
610
670
720
825
970

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

409
20140902

TRANSMISSION.&
DISTRIBUTION CABLES

Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

TRANSMISSION &
DISTRIBUTION CABLES

Covered AL Line Wire


Weatherproof
Item #

ACSR
Walnut
Butternut
Hickory
Pignut
Beech
Chestnut
Almond
Pecan
Filbert
Buckeye
Hackberry
6201-T81
Hornbeam
Linden
Oilnut
Waterash
Shellbark
Planetree

Size
AWG or
MCM

Strand

Insulation
Thickness
(mil)

Outside
Diameter
(in)

Rated
Breaking
Strength
(lb)

XLP
Weight
/MFT
(lb)

Poly
Weight
/MFT
(lb)

XLP
Ampacity

6
4
4
2
2
1
1/0
2/0
3/0
4/0
266.8

6/1
6/1
7/1
6/1
7/1
6/1
6/1
6/1
6/1
6/1
18/1

30
30
30
45
45
45
60
60
60
60
60

.258
.303
.309
.397
.405
.434
.506
.554
.607
.666
.711

1131
1170
2240
2710
3460
3370
4160
5040
6290
7930
6540

49
71.8
81.6
118.1
134.1
145.5
190.4
234.2
288.5
356.5
354.8

47
70.0
79.8
114.8
130.7
141.8
184.9
227.9
281.4
348.5
346.8

105
135
135
180
180
210
235
270
305
345
435

4
2
1/0
2/0
3/0
4/0

7/w
7/w
7/w
7/w
7/w
7/w

30
45
60
60
60
60

.310
.406
.518
.567
.622
.683

1480
2520
4010
4850
6110
7700

62.1
96.1
166.1
203.3
249.4
307.3

60.1
93.3
160.0
196.4
241.4
298.1

145
190
250
290
335
385

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
409
20140902

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Packaging Information
ACSR and ACSR/AW
Size
Stranding
Circular
(ml or AWG)

Turkey

6/1

Swan

6/1

Swanate

7/1

Sparrow

6/1

Sparate

7/1

Robin

6/1

Raven

1/0

6/1

Quail

210

6/1

Pigeon

3/0

6/1

Penguin

4/0

6/1

Waxwing

266800

18/1

Owl
Partridge
Merlin

266800
266800
336400

6/7
26/7
18/1

Linnet

336400

26/7

Oriole

336400

30/7

Chickadee

397500

18/1

Brant

397500

24/7

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size

Code
Word

5,400
16,340
3,835
15,420
3,580
17,910
8,955
2,410
19,390
9,695
6,465
2,250
11,250
5,625
1,910
15,380
7,690
5,125
1,515
12,180
6,090
4,060
9,660
4,830
3,220
7,670
3,835
2,555
6,080
3,040
2,025
14,370
7,185
4,555
10,330
11,390
5,695
16,410
8,205
9,430
9,430
9,640
9,640
4,820
12,790
6,395

Ibis

397500

26/7

Lark

397500

30/7

Pelican

477000

18/1

Flicker

477000

24/7

Hawk

477000

26/7

Hen

477000

30/7

Osprey

556500

18/1

Parakeet

556500

24/7

Dove

556500

26/7

Eagle

556500

30/7

Peacock

605000

24/7

Squab

605000

26/7

Teal

605000

30/19

Swift

636000

36/1

Kingbird

636000

18/1

Rook

636000

24/7

Grosbeak

636000

26/7

Egret

636000

30/19

195
590
220
885
240
1,200
600
220
1,700
885
590
240
1,200
600
220
1,770
885
590
220
1,770
885
590
1,770
885
590
1,770
885
590
1,770
885
590
4,160
2,080
1,560
3,795
4,160
2,080
7,590
3,795
4,970
4,970
4,160
4,160
2,080
6,550
3,275

Coil
NR 30.22
Coil
NR 36.22
Coil
NR 38.22
NR 30.22
Coil
NR 42.28
NR 36.22
NR 30.22
coji
NR 38.22
NR 30.22
Coil
NR 42.28
NR 36.22
NR 30.22
Coil
NR 42.28
NR 36.22
NR 30.22
NR 42.28
NR 36.22
NR 30.22
NR 42.28
NR 36.22
NR 30.22
NR 42.28
NR 36.22
NR 30.22
NR 66.28
NR 48.28
NR 42.28
NR 60.28
NR 66.28
NR 48.28
RMT 84.36
NR 60.28
RM 66.32
NR 66.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.36
NR 60.28

Size
Stranding
Circular
(ml or AWG)

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
13,890
6,945
7,980
7,980
8,030
8,030
4,015
10,660
5,330
11,570
5,785
6,650
6,650
6,890
6,890
3,445
9,140
4,570
9,910
4,955
5,700
5,700
8,400
4,200
9,120
4,560
10,490
5,245
5,245
6,025
6,025
4,015
6,020
6,020
4,515
3,010
8,000
4,000
8,670
4,335
9,980
4,990
4,990

7,590
3,795
4,970
4,970
4,160
4,160
2,080
6,550
3,275
7,590
3,795
4,970
4,970
4,160
4,160
2,080
6,550
3,275
7,590
3,795
4,970
4,970
6,550
3,275
7,590
3,795
9,860
4,930
4,930
3,880
3,880
2,585
4,160
4,160
3,120
2,080
6,550
3,275
7,590
3,795
9,860
4,930
4,930

RMT 84.36
NR 60.28
RM 66.32
NR 66.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.36
NR 60.28
RMT 84.36
NR 60.28
RM 66.32
NR 66.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.36
NR 60.28
RMT 84.36
NR 60.28
RM 66.32
NR 66.28
RMT 84.36
NR 60.28
RMT 84.36
NR 60.28
RMT 84.45
RM 66.32
NR 66.28
RM 66.32
NR 66.28
NR 60.28
RM 66.32
NR 66.28
NR 60.28
NR 48.28
RMT 84.36
NR 60.28
RMT 84.36
NR 60.28
RMT 84.45
RM 66.32
RM 66.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

410
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

Packaging Information
ACSR and ACSR/AW
Code
Word

Size
Stranding
Circular
(ml or AWG)

Flamingo

666600

24/7

Gannet

666600

26/7

Starling

715500

26/7

Redwing

715500

30/19

Coot

795000

36/1

Tern

795000

45/7

Cuckoo

795000

24/7

Condor

795000

54/7

Drake

795000

26/7

Mallard

795000

30/19

Ruddy

900000

45/7

Canary

900000

54/7

Catbird

954000

36/1

Rail

954000

45/7

Cardinal

954000

54/7

Ortolan

1033500

45/7

Curlew

1033500

54/7

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size

Code
Word

11,440
7,630
3,815
12,410
8,270
4,135
11,560
7,710
3,855
8,880
4,440
4,440
9,640
4,820
4,820
12,000
6,000
4,000
9,600
6,400
3,200
11,520
5,760
10,400
6,940
3,470
7,980
3,990
3,990
10,590
5,295
10,180
5,090
8,030
4,015
4,015
14,990
9,990
4,995
9,600
4,800
13,850
9,230
4,615
8,870
4,435

Bluejay

1113000

45/7

Finch

1113000

54/19

Bunting

1192500

45/7

Grackle

1192500

54/19

Bittern

1272000

45/7

Pheasant

1272000

54/19

Dipper

1351500

45/7

Martin

1351500

54/19

Bobolink

1431000

45/7

Plover

1431000

54/19

Nuthatch

1510500

45/7

Parrot

1510500

54/19

Lapwing

1590000

45/7

Falcon

1590000

54/19

Chukar
Bluebird
Kiwi
Thrasher

1780000
2156000
2167000
2312000

84/19
84/19
72/7
76/19

Joree

2515000

76/19

9,830
6,550
3,275
11,380
7,590
3,795
11,380
7,590
3,795
9,860
4,930
4,930
7,760
3,880
3,880
10,750
5,375
3,585
9,830
6,550
3,275
11,800
5,900
11,380
7,590
3,795
9,860
4,930
4,930
10,750
5,375
11,800
5,900
7,760
3,880
3,880
16,125
10,750
5,375
11,800
5,900
16,125
10,750
5,375
11,800
5,900

RMT 84.45
RMT 84.36
NR 60.28
RMT 90.45
RMT 84.36
NR 60.28
RMT 90.45
RMT 84.36
NR 66.28
RMT 84.45
RM 66.32
NR 66.28
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
RM 68.38
NR 60,28
RMT 90.45
RMT 84.36
NR 60.28
RMT 90.45
RM 68.38
RMT 90.45
RMT 84.36
NR 60.28
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 84.45
RM 66.32
NR 66.28
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RW90.45
RM 68.38
RMT 90.45
RM 68.38

Size
Stranding
Circular
(ml or AWG)

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
12,850
8,570
4,285
2,855
8,190
4,095
12,000
8,000
4,000
7,650
3,825
11,245
7,500
3,750
7,170
3,585
10,585
7,060
3,530
6,750
3,375
10,000
6,660
3,335
6,370
3,185
9,470
6,310
3,155
6,040
3,020
9,000
6,000
3,000
5,730
2,865
9,200
7,500
7,000
9,500
6,940
8,730

16,125
10,750
5,375
3,585
11,720
5,860
16,125
10,750
5,375
11,720
5,860
16,125
10,750
5,375
11,720
5,860
16,125
10,750
5,375
11,720
5,860
16,125
10,750
5,375
11,720
5,860
16,125
10,750
5,375
11,720
5,860
16,125
10,750
5,375
11,720
5,860
19,080
18,830
16,120
24,000
17,530
24,000

RMT 96.60
RMT 90.45
RM 68.38
NR 60.28
RMT 90.45
RM 68.38
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 96.60
RMT 96.60
RMT 96.60
RMT 108.74
RMT 96.60
RMT 108.74

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
410
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Packaging Information
ACSR and ACSR/AW

Petrel
Minorca
Leghorn
Guinea
Dotterel
Dorking
Brahma
Cochin

Size
Stranding
Circular
(ml or AWG)
101800
110800
134600
159000
176900
190800
203200
211300

12/7
12/7
12/7
12/7
12/7
12/7
16/19
12/7

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
12,500
11,480
9,450
8,000
7,195
6,665
7,875
6,020

3,175
3,175
3,175
3,175
3,175
3,175
5,330
3,175

NR 48.28
NR 48.28
NR 48.28
NR 48.28
NR 48.28
NR 48.28
NR 60.28
NR 48.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

410
20140921

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Packaging Information
AAC
Size
Stranding
Circular
(ml or AWG)

Peachbell

Rose

Iris

Pansy

Poppy

1/0

Aster

2/0

Phlox

3/0

Oxlip

4/0

Sneezewort

250000

Valerian

250000

19

Daisy

266800

Laurel

266800

19

Peony

300000

19

Tulip

336400

19

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size

Code
Word

56,910
28,455
8,130
35,710
17,855
5,100
22,470
11,235
3,210
17,830
8,915
2,550
14,130
7,065
2,020
11,210
5,605
8,890
4,445
7,050
3,525
5,970
2,985
16,190
16,190
8,095
5,590
2,795
15,170
15,170
7,585
13,490
13,490
6,745
12,030
12,030
6,015

Daffodil

350000

19

Canna

397500

19

Golden Tuft

450000

19

Cosmos

477000

19

Syringa

477000

37

Zinnia

500000

19

Hyacinth

500000

37

Dahlia

556500

19

Mistletoe

556500

37

Meadowsweet 600000

37

Orchid

636000

37

Heuchera

650000

37

1,400
700
200
1,400
700
200
1,400
700
200
1,400
700
200
1,400
700
200
1,400
700
1,400
700
1,400
700
1,400
700
3,800
3,800
1,900
1,400
700
3,800
3,800
1,900
3,800
3,800
1,900
3,800
3,800
1,900

NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
NR 42.28
NR 36.22
NR 42.28
NR 36.22
NR 42.28
NR 36.22
RM 66.32
NR 66.28
NR 48.28
NR 42.28
NR 36.22
RM 66.32
NR 66.28
NR 48.28
RM 66.32
NR 66.28
NR 48.28
RM 66.32
NR 66.28
NR 48.28

Size
Stranding
Circular
(ml or AWG)

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
11,560
11,560
5,780
10,180
10,180
5,090
9,000
9,000
4,500
8,490
8,490
4,245
16,530
8,265
8,265
8,100
8,100
4,050
15,760
7,880
7,880
7,270
7,270
3,635
14,170
7,085
7,085
13,140
6,570
6,570
12,400
6,200
6,200
12,130
6,065
6,065

3,800
3,800
1,900
3,800
3,800
1,900
3,800
3,800
1,900
3,800
3,800
1,900
7,400
3,700
3,700
3,800
3,800
1,900
7,400
3,700
3,700
3,800
3,800
1,900
7,400
3,700
3,700
7,400
3,700
3,700
7,400
3,700
3,700
7,400
3,700
3,700

RM 66.32
NR 66.28
NR 48.28
RM 66.32
NR 66.28
NR 48.28
RM 66.32
NR 66.28
NR 48.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.45
NR 66.32
NR 66.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.45
RM 66.32
NR 66.28
RM 66.32
NR 66.28
NR 48.28
RMT 84.45
RM 66.32
NR 66.28
RMT 84.45
RM 66.32
NR 66.28
RMT 84.45
RM 66.32
NR 66.28
RMT 84.45
RM 66.32
NR 66.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

411
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

Packaging Information
AAC
Code
Word

Size
Stranding
Circular
(mil) or AWG)

Verbena

700000

37

Flag

700000

61

Violet

715500

37

Nasturtium

715500

61

Petunia

750000

37

Cattail

750000

61

Arbutus

795000

37

Lilac

795000

61

Cockscomb

900000

37

Snapdragon

900000

61

Magnolia

954000

37

Goldenrod

954000

61

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size

Code
Word

11,260
5,630
5,630
2,815
14,850
7,425
11,020
5,510
5,510
2,755
14,530
7,265
10,510
5,255
5,255
13,860
6,930
9,920
4,960
4,960
2,480
13,080
6,540
8,760
4,380
4,380
11,550
5,775
8,260
4,130
4,130
10,900
5,450

Hawkweed

1000000

37

Camellia

1000000

61

Bluebell

1033500

37

Larkspur

1033500

61

Marigold

1113000

61

Hawthorn

1192500

61

Narcissus

1272000

61

Columbine

1351500

61

Carnation

1431000

61

Gladiolus

1510500

61

Coreopsis

1590000

61

Jassamine
Cowslip
Sagebrush
Lupine
Bitterroot
Trillium
Bluebonnet

1750000
2000000
2250000
2500000
2750000
3000000
3500000

61
91
91
91
91
127
127

7,400
3,700
3,700
1,850
9,760
4,800
7,400
3,700
3,700
1,850
9,760
4,800
7,400
3,700
3,700
9,760
4,880
7,400
3,700
3,700
1,850
9,760
4,880
7,400
3,700
3,700
9,760
4,880
7,400
3,700
3,700
9,760
4,880

RMT 84.45
RM 66.32
NR 66.28
NR 48.28
RMT 90.45
RM 68.38
RMT 84.45
RM 66.32
NR 66.28
NR 48.28
RMT 90.45
RM 68.38
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
NR 68.38
RMT 84.45
RM 66.32
NR 66.28
NR 48.28
RMT 90.45
RM 68.38
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
RM 68.38
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
RM 68.38

Size
Stranding
Circular
(mil) or AWG)

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
7,880
3,940
3,940
10,400
5,200
7,630
3,815
3,815
10,060
5,030
9,430
4,670
8,720
4,360
8,170
4,085
7,690
3,845
7,270
3,635
6,880
3,440
6,540
3,270
5,940
4,850
4,270
3,840
3,490
3,350
2,840

7,400
3,700
3,700
9,760
4,880
7,400
3,700
3,700
9,760
4,880
9,760
4,880
9,760
4,880
9,760
4,880
9,760
4,880
9,760
4,880
9,760
4,880
9,760
4,880
9,760
9,100
9,100
9,100
9,100
9,530
9,530

RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
NR 68.38
RMT 84.45
RM 66.32
NR 66.28
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT 90.45
RM 68.38
RMT90.45
RM 68.38
RMT90.45
RM 68.38
RMT 90.45
RMT 90.45
RMT 90.45
RMT 90.45
RMT 90.45
RMT 90.45
RMT 90.45

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
411
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Packaging Information
AAAC 6201 Alloy
Approx EC
Size
Cond. with Circular
Equivalent (mil)
Resistance

Akron

30580

Alton

48690

Ames

77470

Azusa

1/0

123300

Anaheim

2/0

155400

Amherst

3/0

195700

Alliance

4/0

246900

266.8

312800

Butte

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size

Code
Word

48,780
24,390
6,970
30,630
15,315
4,375
19,260
9,630
2,750
12,100
6,050
1,730
9,600
4,800
7,600
3,810
6,040
3,020
12,940
12,940
6,470
4,315

Canton

336.4

394500

Cairo

397.5

465400

Darien

477.0

559500

Elgin

556.5

652400

Flint

636.0

740800

Greeley

795.0

927200

1,400
700
200
1,400
700
200
1,400
700
200
1,400
700
200
1,400
700
1,400
700
1,400
700
3,800
3,800
1,900
1,265

NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
Coil
NR 42.28
NR 36.22
NR 42.28
NR 36.22
NR 42.28
NR 36.22
RM 66.32
NR 66.28
NR 48.28
NR 42.28

Note
Length Tolerances: Standard lengths shown in these data are nominal. The
allowable tolerance shall be plus or minus 5% for sizes larger than 77470
kcmil.

Approx EC
Size
Cond. with Circular
Equivalent (mil)
Resistance

Standard Packages
Length
Weight
Reel
(ft)
(lb)
Size
10,260
10,260
5,130
3,420
8,700
8,700
4,350
2,900
7,240
7,240
3,620
2,415
6,210
6,210
3,105
2,070
10,640
5,320
5,320
2,660
8,500
4,250
4,250
2,125

3,800
3,800
1,900
1,265
3,800
3,800
1,900
1,265
3,800
3,800
1,900
1,265
3,800
3,800
1,900
1,265
7,400
3,700
3,700
1,850
7,400
3,700
3,700
1,850

RM 66.32
NR 66.28
NR 48.28
NR 42.28
RM 66.32
NR 66.28
NR 48.28
NR 42.28
RM 66.32
NR 66.28
NR 48.28
NR 42.28
RM 66.32
NR 66.28
NR 48.28
NR 42.28
RMT 84.45
RM 66.32
NR 66.28
NR 48.28
RMT 84.45
RM 66.32
NR 66.28
NR 48.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
8Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

412
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Packaging Information:
TP Twisted Pair

Swallow TP

2x#3-6/1

Sparrow TP

2x#2-6/1

Robin TP

2x#1-6/1

Raven TP

2xl/0-6/1

Quail TP

2x2/0-6/1

Pigeon TP

2x3/0-6/1

Penguin TP

2x4/0-6/1

Waxwing TP

2x266.6-18/1

Partridge TP

2x266.8-26/7

Merlin TP

2x336.4-18/1

Linnet TP

Chickadee TP

2x336.4-26/7

2x397.5-18/1

Length
(ft)
12205
24410
9650
19390
7685
15370
6050
12100
4825
9650
3825
7650
3025
6050
5375
7180
14360
5150
10300
3775
5650
11300
4050
8100
16200
4800
9600

Standard Packages
Weight
Reel
(lb)
Size
1770
3540
1770
3540
1770
3540
1770
3540
1770
3540
1770
3540
1770
3540
3115
4180
8320
3795
7590
2770
4180
8320
3785
7595
15180
4160
8320

48.28 NR
60.28 NR
48.28 NR
60.28NR
48.28 NR
60.28 NR
48.28 NR
60.28 NR
48.28 NR
60.28 NR
48.28 NR
60.28 NR
48.28 NR
66.28 NR
66.28NR
68.38 NR
90.45 RMT
66.28 NR
90.45 RMT
66.28 NR
68.38 NR
90.45 RMT
66.28 NR
90.45 RMT
96.60 RMT
68.38 RM
90.45 RMT

Bare Aluminum Cable ACSR


ACSR/TP
Code
Size
Word
Circular
(ml or AWG)
Ptarmigan TP

2x397.5-20/7

lbis TP

2x397.5-26/7

Pelican TP

2x477.0-18/1

Tatler TP

2x477.0-20/7

Flicker TP

2x477.0-24/7

Hawk TP

2x477.0-26/7

Creeper TP

2x517.0-18/1

Osprey TP

2x556.5-18/1

Parakeet TP

2x556.5-24/7

Dove TP

2x556.5-26/7

Rook TP
Drake TP

2x636.0-24/7
2x795.0-26/7

Tern TP

2x795.0-45/7

Bluejay TP

2x1113.0-45/7

Length
(ft)
5400
10800
6925
13850
4000
8000
4450
8900
5330
10660
5750
11500
3710
7420
3425
6850
4570
9140
4950
9900
8000
3450
6900
4000
6000
5650

Standard Packages
Weight
Reel
(lb)
Size
4780
9570
7590
15180
4160
8320
4780
9570
6550
13100
7590
15180
4160
8320
4160
8320
6550
13100
7590
15180
13100
7590
15180
7170
10750
14180

84.36 RMT
90.45 RMT
84.45 RMT
96.60 RMT
68.38 RM
90.45 RMT
66.38 RM
90.45 RMT
84.45 RMT
96.60 RMT
84.45 RMT
96.60 RMT
68.38 RM
94.45 RMT
68.38 RM
90.45 RMT
68.38 RM
90.45 RMT
90.45 RMT
95.60 RMT
96.60 RMT
84.45 RMT
96.60 RMT
90.45 RMT
96.60 RMT
96.60 RMT

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

413
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

Bare Aluminum Cable ACSR


ACSR/TP
Code
Size
Word
Circular
(ml or AWG)

TRANSMISSION &
DISTRIBUTION CABLES

Packaging Information:
TP Twisted Pair
Bare Aluminum Cable AAC
AAC/TP
Code
Size
Word
Circular
(ml or AWG)
Lily TP

2x#3-7

Iris TP

2x#2-7

Pansy TP

2x#1-7

Poppy TP

2xl/0-7

Aster TP

2x2/0-7

Phlox TP

2x3/0-7

Oxlip TP

2x4/0-7

Valerian TP

2x250.0-19

Tulip TP

2x336.4-19

Canna TP

2x397.5-19

Cosmos TP

2x477.0-19

Dahlia TP

2x556.5-19

Length
(ft)
7090
14180
28360
11250
21000
8915
17830
7050
14100
5600
11200
4450
9900
3550
7100
6800
16000
5300
6010
12020
4400
5090
10180
3600
4245
8490
3125
3635
7250

Standard Packages
Weight
Reel
(lb)
Size
700
1400
2800
1400
2615
1400
2800
1400
2800
1400
2800
1400
2800
1400
2800
3190
7510
3285
3800
7600
3280
3800
7600
3225
3800
7600
3265
3800
7600

42.24 NR
48.48 NR
60.28 NR
48.28 NR
60.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
66.28 NR
84.36 RMT
66.28 NR
68.38 NR
84.36 RMT
66.28 NR
68.36 NR
84.36 RMT
66.28 NR
68.38 NR
90.45 NR
66.28 NR
68.38 NR
90.45 RMT

Bare Aluminum Cable AAC


AAAC Alloy 3201/TP
Code
Size
Word
Circular
(ml or AWG)
Ames TP

2x#2-7

Azusa TP

2x1/0-7

Anaheim TP

2x2/0-7

Amherst TP

2x3/0 -7

Alliance TP

2x4/0-7

Butte TP

2x266.8-19

Length
(ft)
9,700
19,400
6,050
12,100
4,800
9,600
3,810
7,625
3,020
6,040
6,475

Standard Packages
Weight
Reel
(lb)
Size
1,410
3,540
1,400
2,822
1,400
2,800
1,400
2,800
1,400
2,800
3,800

48.28 NR
60.28 NR
48.28 NR
60.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
48.28 NR
66.28 NR
66.28 NR

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
413
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Packaging Information
Covered Line Wire

Pear

Aluminum Conductors
Standard Packages
Size
Stranding Length
Poly
XLP
AWG
(ft)
Weight Weight
(lb)
(lb)
4

2,600
8,500

123
402

126
41

Coil
NRC 30.18

AAC 1350-H19 Stranded


Code
Aluminum Conductors
Standard Packages
Word
Size
Stranding Length
Poly
XLP
AWG or
(ft)
Weight Weight
Cmils
(lb)
(lb)
Apricot

Peach

Quince

1/0

Orange
210
Fig
3/0
Olive
4/0
Pomegranate 4/0
Mulberry
266800
Anona
336400
Molles
397500
Huckleberry 477000
Paw Paw
556500
Breadfruit 636000
Persimmon 795000
Grapefruit 1033500

7
7
7
19
19
19
19
37
37
61
61
61

2,500
7,000
1,500
7,500
1,000
4,700
3,750
4,400
3,500
3,800
3,000
2,400
2,000
3,300
2,800
2,500
2,200
1,700

127
356
126
630
136
637
623
898
880
942
917
909
915
1,774
1,463
1,812
1,958
1,927

129
361
131
653
141
661
645
926
905
968
941
930
938
1,815
1,772
1,857
2,002
1,966

Reel
Size

Reel
Size

Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
NRC 36.24
NRC 40.24
NRC 40.24
NRC 40.24
NRC 40.24
NRC 40.24
NRC 40.24
NRC 50.32
NRC 50.32
NRC 50.32
NRC 50.32
NRC 50.32

ACSR
Code
Word

Aluminum Conductors
Standard Packages
Size
Stranding Length
Poly
XLP
AWG or
(ft)
Weight Weight
Cmils
(lb)
(lb)

Butternut

611

Hickory

7/1

Pignut

6/1

Beech

7/1

Chestnut

6/1

Almond

1/0

6/1

210
3/0
410
266800

6/1
6/1
6/1
18/1

Pecan
Filbert
Buckeye
Hackberry

1,700
5,100
1,500
6,000
1,200
6,400
1,100
5,600
1,000
5,100
1,000
4,000
3,200
3,800
3,000
2,400

119
122
Coil
357
366 NRC 30.18
120
122
Coil
479
490 NRC 30.18
138
142
Coil
735
756 NRC 36.24
144
148
Coil
732
751 NRC 36.24
142
146
Coil
723
742 NRC 36.24
185
190
Coil
740
762 NRC 36.24
729
749 NRC 36.24
1,069 1,096 NRC 40.24
1,046 1,070 NRC 40.24
832
852 NRC 40.24

AAAC Alloy 6201-T81


Code
Aluminum Conductors
Standard Packages
Word
Size
Stranding Length
Poly
XLP
AWG or
(ft)
Weight Weight
Cmils
(lb)
(lb)
Hornbeam

48690

Linden

77470

Oilnut

123300

Waterash
Shellbark
Planetree

155400
195700
246900

7
7
71

1,700
5,100
1,200
6,400
1,000
4,000
3,200
3,800
3,000

Reel
Size

102
307
112
597
160
640
628
917
894

106
317
115
615
166
664
651
948
922

Reel
Size

Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
NRC 36.24
NRC 40.24
NRC 40.24

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

414
20140921

TRANSMISSION.&
DISTRIBUTION CABLES

AAC
Code
Word

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

AAC
2 Layer 15kV
ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.

Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:

Item #

TW15-2-AAC-1/0-7
TW15-2-AAC-2/0-7
TW15-2-AAC-3/0-7
TW15-2-AAC-4/0-7
TW15-2-AAC-266.8-19
TW15-2-AAC-336.4-19
TW15-2-AAC-397.5-19
TW15-2-AAC-477-19
TW15-2-AAC-556.5-37
TW15-2-AAC-636-37

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636

7
7
7
7
19
19
19
19
37
37

336
376
423
475
537
603
659
722
780
835

75
75
75
75
75
75
75
75
75
75

75
75
75
75
75
75
75
75
75
75

636
676
723
775
837
903
959
1022
1080
1135

1791
2259
2736
3447
4473
5535
6399
7524
8946
10260

196
230
272
325
387
466
535
623
708
794

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

420
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

AAC
3 Layer 15kV-35kV

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.
Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:

Item #

15kV
TW15-3-AAC-1/0-7
TW15-3-AAC-2/0-7
TW15-3-AAC-3/0-7
TW15-3-AAC-4/0-7
TW15-3-AAC-266.8-19
TW15-3-AAC-336.4-19
TW15-3-AAC-397.5-19
TW15-3-AAC-477-19
TW15-3-AAC-556.5-37
TW15-3-AAC-636-37
TW15-3-AAC-795-37

ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors
Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Conductor
Shield
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636
795

7
7
7
7
19
19
19
19
37
37
37

336
376
423
475
537
603
659
722
780
835
932

15
15
15
15
15
15
15
15
20
20
20

75
75
75
75
75
75
75
75
75
80
80

75
75
75
75
75
75
75
75
75
80
80

666
706
753
805
867
933
989
1052
1120
1195
1292

1791
2259
2736
3447
4473
5535
6399
7524
8946
10260
12510

210
246
289
343
407
487
558
648
742
846
1020

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

421
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

AAC
3 Layer 15kV-35kV
Item #

25kV
TW25-3-AAC-1/0-7
TW25-3-AAC-2/0-7
TW25-3-AAC-3/0-7
TW25-3-AAC-4/0-7
TW25-3-AAC-266.8-19
TW25-3-AAC-336.4-19
TW25-3-AAC-397.5-19
TW25-3-AAC-477-19
TW25-3-AAC-556.5-37
TW25-3-AAC-636-37
TW25-3-AAC-795-37
35kV
TW35-3-AAC-1/0-7
TW35-3-AAC-2/0-7
TW35-3-AAC-3/0-7
TW35-3-AAC-4/0-7
TW35-3-AAC-266.8-19
TW35-3-AAC-336.4-19
TW35-3-AAC-397.5-19
TW35-3-AAC-477-19
TW35-3-AAC-556.5-37
TW35-3-AAC-636-37
TW35-3-AAC-795-37

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Conductor
Shield
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636
795

7
7
7
7
19
19
19
19
37
37
37

336
376
423
475
537
603
659
722
780
835
932

15
15
15
15
15
15
15
20
20
20
20

125
125
125
125
125
125
125
125
125
125
125

125
125
125
125
125
125
125
125
125
125
125

866
906
953
1005
1067
1133
1189
1262
1320
1375
1472

1791
2259
2736
3447
4473
5535
6399
7524
8946
10260
12510

309
350
400
460
531
621
698
806
899
995
1181

1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636
795

7
7
7
7
19
19
19
19
37
37
37

336
376
423
475
537
603
659
722
780
835
932

15
15
15
15
15
15
15
20
20
20
20

175
175
175
175
175
175
175
175
175
175
175

125
125
125
125
125
125
125
125
125
125
125

966
1006
1053
1105
1167
1233
1289
1362
1420
1475
1572

1791
2259
2736
3447
4473
5535
6399
7524
8946
10260
12510

368
411
464
527
603
696
777
889
987
1085
1278

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
421
20160208

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

AAC
3 Layer 35kV
Electrical Properties

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.
Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:
Item #

TW35-3-AAC-2-7
TW35-3-AAC-1/0-7
TW35-3-AAC-2/0-7
TW35-3-AAC-3/0-7
TW35-3-AAC-4/0-7
TW35-3-AAC-266.8-7
TW35-3-AAC-336.4-19
TW35-3-AAC-397.5-19
TW35-3-AAC-477-19
TW35-3-AAC-556.5-19
TW35-3-AAC-636-19
TW35-3-AAC-795-19
TW35-3-AAC-954-37
TW35-3-AAC-1033-37
TW35-3-AAC-636-37
TW35-3-AAC-795-37

Size Strands AC
AC
AC
AWG or
Resistance Resistance Resistance
kcmil
@25C
@75C
@90C
ohms/mile ohms/mile ohms/mile
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636
795
954
1033
1272
1431

7
7
7
7
7
7
19
19
19
19
19
19
37
37
61
61

1.4020
0.8820
0.7000
0.5560
0.4410
0.3500
0.2780
0.2350
0.1970
0.1690
0.1490
0.1200
0.1010
0.0930
0.0770
0.0700

1.1810
1.0580
0.8390
0.6670
0.5290
0.4200
0.3330
0.2820
0.2360
0.2030
0.1790
0.1440
0.1210
0.1120
0.0930
0.0830

1.7640
1.1100
0.0881
0.6990
0.5550
0.4400
0.3500
0.2960
0.2480
0.2130
0.1870
0.1510
0.1270
0.1170
0.0970
0.0870

GMR
(ft)

Inductive
Reactance
ohms/mile
w/H-46D

Inductive
Reactance
ohms/mile
w/H-35D

Inductive
Reactance
ohms/mile
w/RTL-15

0.0088
0.0109
0.0122
0.0137
0.0154
0.0169
0.0200
0.0215
0.0239
0.0251
0.0274
0.0304
0.0328
0.0341
0.0385
0.0405

0.5691
0.5432
0.5295
0.5154
0.5012
0.4900
0.4695
0.4607
0.4479
0.4420
0.4313
0.4187
0.4095
0.4048
0.3901
0.3839

0.5763
0.5503
0.5366
0.5226
0.5084
0.4971
0.4767
0.4679
0.4550
0.4491
0.4385
0.4258
0.4166
0.4199
0.3972
0.3910

0.5252
0.4992
0.4855
0.4715
0.4573
0.4460
0.4256
0.4168
0.4039
0.3980
0.3874
0.3747
0.3655
0.3608
0.3461
0.3399

ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors
Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Inductive Inductive Impedance Impedance Impedance


Reactance Reactance Z@75C Z@75C Z@75C
ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile
w/RTL-46 w/RTL-G095 H-46D
H-35D
RTL-15
0.5691
0.5432
0.5295
0.5154
0.5012
0.4900
0.4695
0.4607
0.4479
0.4420
0.4313
0.4187
0.4095
0.4048
0.3901
0.3839

0.5235
0.5975
0.5839
0.5698
0.5556
0.5443
0.5239
0.5151
0.5023
0.4963
0.4857
0.4731
0.4639
0.4591
0.4444
0.4383

1.7747
1.1889
0.9924
0.8427
0.7286
0.6451
0.5758
0.5401
0.5064
0.4862
0.4669
0.4427
0.4270
0.4200
0.4009
0.3928

1.7770
1.1921
0.9962
0.8470
0.7335
0.6505
0.5816
0.5462
0.5127
0.4927
0.4735
0.4495
0.4339
0.4268
0.4078
0.3998

1.7611
1.1694
0.9696
0.8165
0.6991
0.6124
0.5406
0.5031
0.4679
0.4466
0.4266
0.4014
0.3851
0.3778
0.3582
0.3500

Impedance
Z@75C
ohms/mile
RTL-46

Impedance
Z@75C
ohms/mile
RTL-G095

1.7747
1.1889
0.9924
0.8427
0.7286
0.6451
0.5758
0.5401
0.5064
0.4862
0.4669
0.4427
0.4270
0.4200
0.4009
0.3928

1.7929
1.2147
1.0224
0.8770
0.7670
0.6873
0.6209
0.5871
0.5550
0.5361
0.5175
0.4945
0.4794
0.4726
0.4540
0.4461

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

426
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS

1 Color
2 Density (23)
3 Tensile strength before aging
Elongation at break before aging
4 Performance after air oven aging
Testing temperature
Testing time
Tensile strength variation before & after aging
At-break-elongation variation before & after aging
5 Hot set test (0.2MPa, 200, 15min)
Elongation under load
Variation after cool
6 Volume resistivity at 20
7 Volume resistivity at 90
8 Volume resistivity at 90 (volume resistivity at 90,
after air oven aging (100* 168 hours))
The second layer data (middle layer) 35kV XLPE, color natural (clear)
DESCRIPTION
1 Color
2 Density (23)
3 Tensile strength before aging
Elongation at break before aging
4 Performance after air oven aging
Testing temperature
Testing time
Tensile strength variation before & after aging
At-break-elongation variation before & after aging
5 Hot set test (0.2MPa, 200, 15min)
Elongation under load
Variation after cool
6 Dielectric loss factor , 20, 50Hz
7 Dielectric coefficient , 20, 50Hz
8 Volume resistivity at 20
9 Dielectric strength

REQUIRED VALUE

g/cm3
Mpa
%

Black
1.11
min 14
min 200

hours
%
%

1352
168
15
-7.5

%
%
.cm
.cm

43
0
33
181

.cm

124

UNIT

REQUIRED VALUE

g/cm3
Mpa
%

clear, natural
0.926
min 23
min 500

hours
%
%

1352
168
-9.3
-17

%
%
.m
MV/m

35
0
0.0004
2.1
1.5x1013
35

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

427
20160216

TRANSMISSION.&
DISTRIBUTION CABLES

The first layer data (inner layer) 35kV semi-conducting shield compound
DESCRIPTION
UNIT

TRANSMISSION &
DISTRIBUTION CABLES

SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS


The third layer data (outer layer) 35kV XLPE, Gray, UV resistant, weather resistant
DESCRIPTION
UNIT
REQUIRED VALUE
1 Color
2 Density (23)
3 Tensile strength before aging
Elongation at break before aging
4 Performance after air oven aging
Testing temperature
Testing time
Tensile strength variation before & after aging
At-break-elongation variation before & after aging
5 Hot set test (0.2MPa, 200, 15min)
Elongation under load
Variation after cool
6 Dielectric loss factor, 20, 50Hz
7 Dielectric coefficient, 20, 50Hz
8 Volume resistivity at 20
9 Dielectric strength

g/cm3
Mpa
%

Gray
0.926
min 24.7
min 521

hours
%
%

1352
168
-7
-5

%
%
.m
MV/m

33
0
0.00005
2.0
1.4x1015
35

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
427
20160216

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

AAAC
2 Layer 15kV

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.
Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:

Item #

TW15-2-AAAC-48.69-7
TW15-2-AAAC-77.47-7
TW15-2-AAAC-123.3-7
TW15-2-AAAC-155.4-7
TW15-2-AAAC-195.7-7
TW15-2-AAAC-246.9-7
TW15-2-AAAC-312.8-19
TW15-2-AAAC-394.5-19
TW15-2-AAAC-465.4-19
TW15-2-AAAC-559.5-19
TW15-2-AAAC-652.4-19
TW15-2-AAAC-740.8-37

ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors
Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size
AWG or
kcmil

Equivalent
AAC
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

48.69
77.47
123.3
155.4
195.7
246.9
312.8
394.5
465.4
559.5
652.4
740.8

4
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636

7
7
7
7
7
7
19
19
19
19
19
37

250
316
398
447
502
563
642
720
782
858
927
990

75
75
75
75
75
75
75
75
75
75
75
80

75
75
75
75
75
75
75
75
75
75
75
80

550
616
698
747
802
863
942
1020
1082
1158
1227
1310

1584
2520
4014
4851
6111
7704
9900
11970
14040
16920
19710
21960

124
165
225
265
314
376
450
543
623
727
828
938

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

422
20160108

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

AAAC
3 Layer 15k-35kV

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.
Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:
Item #

15kV
TW15-3-AAAC-48.69-7
TW15-3-AAAC-77.47-7
TW15-3-AAAC-123.3-7
TW15-3-AAAC-155.4-7
TW15-3-AAAC-195.7-7
TW15-3-AAAC-246.9-7
TW15-3-AAAC-312.8-19
TW15-3-AAAC-394.5-19
TW15-3-AAAC-465.4-19
TW15-3-AAAC-559.5-19
TW15-3-AAAC-652.4-19
TW15-3-AAAC-740.8-37

Size
AWG or
kcmil

Equivalent
AAC
AWG or
kcmil

Stranding

48.69
77.47
123.3
155.4
195.7
246.9
312.8
394.5
465.4
559.5
652.4
740.8

4
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636

7
7
7
7
7
7
19
19
19
19
19
37

ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors
Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Conductor Covering Covering


Covering
Diameter Thickness Thickness Thickness
(mil)
Conductor
Inner
Outer
Shield
Layer
Layer
(mil)
(mil)
(mil)
250
316
398
447
502
563
642
720
783
858
927
990

15
15
15
15
15
15
15
15
15
15
20
20

75
75
75
75
75
75
75
75
75
75
75
75

75
75
75
75
75
75
75
75
75
75
75
75

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

580
646
728
777
832
893
972
1050
1113
1188
1267
1330

1584
2520
4014
4851
6111
7704
9900
11970
14040
16920
19710
21960

137
179
241
283
334
397
473
568
649
755
894
963

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

423
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

AAAC
3 Layer 15k-35kV
Item #

25kV
TW25-3-AAAC-48.69-7
TW25-3-AAAC-77.47-7
TW25-3-AAAC-123.3-7
TW25-3-AAAC-155.4-7
TW25-3-AAAC-195.7-7
TW25-3-AAAC-246.9-7
TW25-3-AAAC-312.8-19
TW25-3-AAAC-394.5-19
TW25-3-AAAC-465.4-19
TW25-3-AAAC-559.5-19
TW25-3-AAAC-652.4-19
TW25-3-AAAC-740.8-37
TW25-3-AAAC-927.2-37
35kV
TW35-3-AAAC-48.69-7
TW35-3-AAAC-77.47-7
TW35-3-AAAC-123.3-7
TW35-3-AAAC-155.4-7
TW35-3-AAAC-195.7-7
TW35-3-AAAC-246.9-7
TW35-3-AAAC-312.8-19
TW35-3-AAAC-394.5-19
TW35-3-AAAC-465.4-19
TW35-3-AAAC-559.5-19
TW35-3-AAAC-652.4-19

Size
AWG or
kcmil

Equivalent
AAC
AWG or
kcmil

Stranding

Conductor Covering Covering


Covering
Diameter Thickness Thickness Thickness
(mil)
Conductor
Inner
Outer
Shield
Layer
Layer
(mil)
(mil)
(mil)

48.69
77.47
123.3
155.4
195.7
246.9
312.8
394.5
465.4
559.5
652.4
740.8
927.2

4
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5
636
795

7
7
7
7
7
7
19
19
19
19
19
37
37

250
316
398
447
502
563
642
720
783
858
927
990
1108

15
15
15
15
15
15
15
15
15
20
20
20
20

125
125
125
125
125
125
125
125
125
125
125
125
125

48.69
77.47
123.3
155.4
195.7
246.9
312.8
394.5
465.4
559.5
652.4

4
2
1/0
2/0
3/0
4/0
266.8
336.4
397.5
477
556.5

7
7
7
7
7
7
19
19
19
19
19

250
316
398
447
502
563
642
720
783
858
927

15
15
15
15
15
15
15
15
15
20
20

175
175
175
175
175
175
175
175
175
175
175

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

125
125
125
125
125
125
125
125
125
125
125
125
125

780
846
928
977
1032
1093
1172
1251
1313
1398
1467
1530
1648

1584
2520
4014
4851
6111
7704
9900
11970
14040
16920
19710
21960
27450

225
275
348
396
454
525
611
716
805
932
1044
1148
1389

125
125
125
125
125
125
125
125
125
125
125

880
946
1028
1077
1132
1193
1272
1351
1412
1498
1567

1584
2520
4014
4851
6111
7704
9900
11970
14040
16920
19710

278
333
411
462
523
598
689
799
892
1024
1141

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
423
20160208

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSR
2 Layer 15kV
ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.

Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:

Item #

TW15-2-ACSR-4-6/1
TW15-2-ACSR-2-6/1
TW15-2-ACSR-1/0-6/1
TW15-2-ACSR-2/0-6/1
TW15-2-ACSR-3/0-6/1
TW15-2-ACSR-4/0-6/1
TW15-2-ACSR-266.8-18/1
TW15-2-ACSR-266.8-26/7
TW15-2-ACSR-336.4-18/1
TW15-2-ACSR-336.4-26/7
TW15-2-ACSR-336.4-30/7
TW15-2-ACSR-397.5-18/1
TW15-2-ACSR-397.5-24/7
TW15-2-ACSR-397.5-26/7

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

4
2
1/0
2/0
3/0
4/0
266.8
266.8
336.4
336.4
336.4
397.5
397.5
397.5

6/1
6/1
6/1
6/1
6/1
6/1
18/1
26/7
18/1
26/7
30/7
18/1
24/7
26/7

250
316
398
447
502
563
609
642
684
720
741
743
772
783

75
75
75
75
75
75
75
75
75
75
75
75
75
75

75
75
75
75
75
75
75
75
75
75
75
75
75
75

550
616
698
747
802
863
909
942
984
1020
1041
1043
1072
1083

1767
2708
4161
5045
6289
7933
6536
10735
8246
13395
16435
9443
13870
1545

136
184
255
303
362
432
441
452
536
555
621
611
609
645

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

424
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

ACSR
2 Layer 15kV
Item #

TW15-2-ACSR-477-24/7
TW15-2-ACSR-477-26/7
TW15-2-ACSR-477-30/7
TW15-2-ACSR-556.5-18/1
TW15-2-ACSR-556.5-24/7
TW15-2-ACSR-556.5-26/7
TW15-2-ACSR-636-18/1
TW15-2-ACSR-636-24/7
TW15-2-ACSR-636-26/7
TW15-2-ACSR-795-26/7
TW15-2-ACSR-795-45/7

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

477
477
477
556.5
556.5
556.5
636
636
636
795
795

24/7
26/7
30/7
18/1
24/7
26/7
18/1
24/7
26/7
26/7
45/7

846
858
883
879
914
927
940
977
990
1108
1063

75
75
75
75
75
75
75
75
75
80
80

75
75
75
75
75
75
75
75
75
80
80

1146
1158
1183
1179
1214
1227
1240
1277
1290
1428
1383

16340
18525
22610
13015
18810
21470
14915
20900
23940
29925
20995

719
762
854
813
828
878
912
936
993
1234
1031

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
424
20160208

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

ACSR
3 Layer 15kV-35kV

Construction
Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact
depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical
requirements of ICEA S-61-402. Available with
track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant
Cross-linked Polyethylene (XLPE) covering per
ASTM D2656. The minimum thickness of each
layer at any point shall not be less than listed in
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resistance.
Specification
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifications:
Item #

15kV
TW15-3-ACSR-4-6/1
TW15-3-ACSR-2-6/1
TW15-3-ACSR-1/0-6/1
TW15-3-ACSR-2/0-6/1
TW15-3-ACSR-3/0-6/1
TW15-3-ACSR-4/0-6/1
TW15-3-ACSR-266.8-18/1
TW15-3-ACSR-266.8-26/7
TW15-3-ACSR-336.4-18/1
TW15-3-ACSR-336.4-26/7
TW15-3-ACSR-336.4-30/7
TW15-3-ACSR-397.5-18/1
TW15-3-ACSR-397.5-24/7
TW15-3-ACSR-397.5-26/7
TW15-3-ACSR-477-24/7

ASTM B230 Standard Specification for Aluminum 1350H19 Wire for Electrical Purposes
ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors,
Coated-Steel Reinforced (ACSR)
ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for
Electrical Purposes
ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors
ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
ASTM D2656 Standard Specification for
Cross-linked Polyethylene Insulation for Wire
and Cable Rated 2001 to 35 000 V
ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire
and Cable
ICEA S-70-547 Standard Specification for
Weather Resistant Polyethylene Covered Conductors
Notes
Full hardware solution is available, including
spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Conductor
Shield
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

4
2
1/0
2/0
3/0
4/0
266.8
266.8
336.4
336.4
336.4
397.5
397.5
397.5
477

6/1
6/1
6/1
6/1
6/1
6/1
18/1
26/7
18/1
26/7
30/7
18/1
24/7
26/7
24/7

250
316
398
447
502
563
609
642
684
720
741
743
772
783
846

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

75
75
75
75
75
75
75
75
75
75
75
75
75
75
75

75
75
75
75
75
75
75
75
75
75
75
75
75
75
75

580
646
728
777
832
893
939
972
1014
1050
1071
1073
1102
1113
1176

1767
2708
4161
5045
6289
7933
6536
10735
8246
13395
16435
9443
13870
15485
16340

151
202
278
330
393
471
474
553
570
669
935
653
707
770
824

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

425
20160208

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an
uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other
objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and
hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION &
DISTRIBUTION CABLES

ACSR
3 Layer 15kV-35kV
Item #

Size
AWG or
kcmil

Stranding

Conductor
Diameter
(mil)

Covering
Thickness
Conductor
Shield
(mil)

Covering
Thickness
Inner
Layer
(mil)

Covering
Thickness
Outer
Layer
(mil)

Cable
O.D.
(mil)

Rated
Strength
(lb)

Weight
(lb/MFT)

TW15-3-ACSR-477-26/7
TW15-3-ACSR-477-30/7
TW15-3-ACSR-556.5-18/1
TW15-3-ACSR-556.5-24/7
TW15-3-ACSR-556.5-26/7
TW15-3-ACSR-636-18/1
TW15-3-ACSR-636-26/7
25kV
TW25-3-ACSR-1/0-6/1
TW25-3-ACSR-2/0-6/1
TW25-3-ACSR-3/0-6/1
TW25-3-ACSR-4/0-6/1
TW25-3-ACSR-266.8-18/1
TW25-3-ACSR-266.8-26/7
TW25-3-ACSR-336.4-18/1
TW25-3-ACSR-336.4-26/7
TW25-3-ACSR-336.4-30/7
TW25-3-ACSR-397.5-18/1
TW25-3-ACSR-397.5-24/7
TW25-3-ACSR-397.5-26/7
TW25-3-ACSR-477-24/7
TW25-3-ACSR-477-26/7
TW25-3-ACSR-477-30/7
TW25-3-ACSR-556.5-18/1
TW25-3-ACSR-556.5-24/7
TW25-3-ACSR-556.5-26/7
35kV
TW35-3-ACSR-1/0-6/1
TW35-3-ACSR-2/0-6/1
TW35-3-ACSR-4/0-6/1
TW35-3-ACSR-266.8-18/1
TW35-3-ACSR-266.8-26/7
TW35-3-ACSR-336.4-18/1
TW35-3-ACSR-336.4-26/7
TW35-3-ACSR-336.4-30/7
TW35-3-ACSR-397.5-18/1
TW35-3-ACSR-397.5-24/7
TW35-3-ACSR-397.5-26/7
TW35-3-ACSR-477-24/7
TW35-3-ACSR-477-26/7
TW35-3-ACSR-477-30/7
TW35-3-ACSR-556.5-18/1
TW35-3-ACSR-556.5-24/7
TW35-3-ACSR-556.5-26/7
TW35-3-ACSR-636-18/1
TW35-3-ACSR-636-26/7
TW35-3-ACSR-795-26/7
TW35-3-ACSR-795-45/7

477
477
556.5
556.5
556.5
636
636

26/7
30/7
18/1
24/7
26/7
18/1
26/7

858
883
879
914
927
940
990

15
15
20
20
20
20
20

75
75
75
75
75
75
75

75
75
75
75
75
75
75

1188
1213
1219
1254
1267
1280
1330

18525
22610
13015
18810
21470
14915
23940

899
1274
874
949
1036
1200
1373

1/0
2/0
3/0
4/0
266.8
266.8
336.4
336.4
336.4
397.5
397.5
397.5
477
477
477
556.5
556.5
556.5

6/1
6/1
6/1
6/1
18/1
26/7
18/1
26/7
30/7
18/1
24/7
26/7
24/7
26/7
30/7
18/1
24/7
26/7

398
447
502
563
609
642
684
720
741
743
772
783
846
858
883
879
914
927

15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20

125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

928
977
1032
1093
1139
1172
1214
1250
1271
1273
1302
1313
1386
1398
1423
1419
1454
1467

4161
5045
6289
7933
6536
10735
8246
13395
16435
9443
13870
15485
16340
18525
22610
13015
18810
21470

385
443
513
600
608
692
714
818
1086
804
863
926
999
1076
1458
1045
1124
1213

1/0
2/0
4/0
266.8
266.8
336.4
336.4
336.4
397.5
397.5
397.5
477
477
477
556.5
556.5
556.5
636
636
795
795

6/1
6/1
6/1
18/1
26/7
18/1
26/7
30/7
18/1
24/7
26/7
24/7
26/7
30/7
18/1
24/7
26/7
18/1
26/7
26/7
45/7

398
447
563
609
642
684
720
741
743
772
783
846
858
883
879
914
927
940
990
1107
1063

15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
20

175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175

125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

1028
1077
1193
1239
1272
1314
1350
1371
1373
1402
1413
1486
1498
1523
1519
1554
1567
1580
1630
1747
1703

4161
5045
7933
6536
10735
8246
13395
16435
9443
13870
15485
16340
18525
22610
13015
18810
21470
14915
23940
29925
20995

448
509
673
684
770
794
901
1170
889
949
1013
1091
1168
1552
1138
1220
1309
1637
1826
2146
1892

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
425
20160208

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Covered CU Line Wire


Weatherproof

Application
Primary and secondary distribution on pole lines, service from pole to weatherhead, distribution infoors and out. Mining, industrial, railroad and other application.
Specification
ASTM B1 Hard-Drawn Copper Wire
ASTM B2 Medium-Hard-Drawn Copper WIre
ASTM B3 Soft or Annealed Copper Wire
ASTM B4 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
ASTM D-1248 Polyethylene Plastics, Molding and Extrusion Materials
ANSI C-8.35 Specifications for Weather-Resistant Polyethylene-Covered Wire and Cable

Item #

Size

Stranding

Insulation
Thickness
(in)

Poly
Weight
/MFT
(lb)

XLP
Weight
/MFT
(lb)

14S-01WP
12S-01WP
10S-01WP
9S-01WP
8S-01WP
6S-01WP
4S-01WP
3S-01WP
2S-01WP
1S-01WP
1/0S-01WP
2/0S-01WP
6-01WP-7
4-01WP-7
2-01WP-7
1-01WP-7
1/0-01WP-7
1/0-01WP-19
2/0-01WP-7
2/0-01WP-19
3/0-01WP-7
3/0-01WP-19
4/0-01WP-7
4/0-01WP-19
250-01WP-19
300-01WP-19
350-01WP-19
500-01WP-37
750-01WP-61

14
12
10
9
8
6
4
3
2
1
1/0
2/0
6
4
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
300
350
500
750

SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
SOLID
7/W
7/W
7/W
7/W
7/W
19/W
7/W
19/W
7/W
19/W
7/W
19/W
19/W
19/W
19/W
37/W
61/W

2/64
2/64
2/64
2/64
2/64
2/64
2/64
3/64
3/64
3/64
4/64
4/64
2/64
2/64
3/64
3/64
4/64
4/64
4/64
4/64
4/64
4/64
4/64
4/64
4/64
4/64
4/64
5/64
6/64

16.0
24.0
36.5
45.0
56.0
87.0
136.0
176.0
219.0
273.0
350.0
437.0
91.5
143.0
230.0
287.0
367.0
367.0
458.0
458.0
572.0
572.0
715.0
715.0
834.0
996.0
1157.0
1648.0
2481.0

16.5
24.6
37.1
45.7
56.8
87.8
137.0
177.4
222.0
277.0
355.0
443.0
92.0
144.0
233.0
291.0
372.0
372.0
464.0
464.0
578.0
578.0
722.0
722.0
842.0
1005.0
1166.0
1659.0
2494.0

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

415
20140902

TRANSMISSION.&
DISTRIBUTION CABLES

Description
Copper line wire available in vearious sizes, tempers and strandings with HMW-Polyethylene covering or crosslinked.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Cathodic Protection Cable

Application
Designed for use in Cathodic systems to protect against galvanic and electrolytic corrosion of underground or submerged metallic objects. Specifically applied to underground pipelines, dams and
lock gates, fresh or salt water steel piles, tanks, condensers, and ship hulls.
Specification
ASTM B-3 Bare Copper
ASTM B-8 Class B Stranding
ICEA S-70-547
ASTM 1248

Item #

8-01CPC
6-01CPC
4-01CPC
2-01CPC
1-01CPC
1/0-01CPC
2/0-01CPC
3/0-01CPC
4/0-01CPC
250-01CPC
350-01CPC
500-01CPC

Size AWG or MCM

Stranding

Insulation Thickness
(mil)

Nominal Weight
/MFT
(lb)

Nominal Diameter
(in)

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0973
37/.1162

110
110
110
110
125
125
125
125
125
155
155
155

0.370
0.410
0.460
0.520
0.590
0.630
0.680
0.735
0.790
0.900
1.010
1.140

90
125
180
272
337
415
510
625
777
935
1269
1770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

416
20140110

TRANSMISSION.&
DISTRIBUTION CABLES

Description
Soft drawn bare copper strand. High-molecular-weight, low density black polyethylene (HMW PE)
covering.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Transformer Riser Wire


(Tap Wire)

Construction
Soft drawn copper conductors, either solid or stranded, covered with HMW Polyethylene.
Standards
ASTM B-3
ASTM B-8
ANSI C-8.35

Item #

TRW-8S
TRW-6S
TRW-6
TRW-4S
TRW-4

Size

Stranding

Covering
Thickness
(mil)

Diameter
Bare Conductor
(mil)

Diameter
Covered
(mil)

Weight
/MFT
(lb)

8
6
6
4
4

SOLID
SOLID
.0612 7 STRANDS
SOLID
.0772 7 STRANDS

110
110
110
110
110

128.5
162.0
184.0
204.3
232.0

348.5
382.0
404.0
424.3
452.0

83
117
122
170
177

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

417
20140902

TRANSMISSION.&
DISTRIBUTION CABLES

Application
Used as non-insulated transformer risers intended to reduce faults due to atmospheric conditions,
vibrations, and crossed leads.

TRANSMISSION &
DISTRIBUTION CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

MULTIPLEX CABLES
Table of Contents
Aluminum Duplex Overhead Service Drop 600V................................................................206
Aluminum Triplex Overhead Service Drop 600V ................................................................207
Aluminum Quadruplex Overhead Service Drop 600V .......................................................208
Copper Duplex Service Drop Cable 600V ............................................................................227

Aluminum Single Secondary Type URD Cable ...................................................................209


Aluminum Duplex Secondary Type URD Cable ..................................................................210
Aluminum Triplex Secondary Type URD Cable ...................................................................211
Aluminum Quadruplex Secondary Type URD Cable ..........................................................212
Aluminum Mobile Home Feeder Type URD ........................................................................213
Packaging Information
Duplex Overhead Service Drop.........................................................................................214
Triplex Overhead Service Drop .........................................................................................215
Quadruplex Overhead Service Drop.................................................................................216
Secondary Type URD Cable 600V: Single, Duplex, Triplex, Quadruplex ........................217

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

1000
20151123

MULTIPLEX CABLES

Copper Triplex Service Drop Cable 600V .............................................................................228


Copper Quadruplex Service Drop Cable 600V ....................................................................229

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Duplex Overhead Service Drop


600V
Applications
To supply 120V aerial service for temporary service at construction sites, outdoor or street lighting.
For service at 600V or lower at a conductor temperature of 75C maximum.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

Item #

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

AAC
Pekingese
6
Solid
Collie
6
7
Dachshund
4
Solid
Spaniel
4
7
Doberman
2
7
Malemute
1/0
19
ACSR Neutral Messenger
Setter
6
Solid
Shepherd
6
7
Eskimo
4
Solid
Terrier
4
7
Chow
2
7
Bull
1/0
19
AAAC 6201 Alloy Neutral Messenger
Chihuahua
6
Solid
Vizsla
6
7
Harrier
4
Solid
Whippet
4
7
Schnauzer
2
7
Heeler
1/0
19

Phase
Conductor
Insulation
Thickness
(mil)

Bare
Neutral
Messenger
Size AWG

Bare
Neutral
Messenger
Stranding

Bare
Neutral
Messenger
Breaking
(lb)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Ampacity
XLP

Ampacity
Poly

45
45
45
45
45
60

6
6
4
4
2
1/0

7
7
7
7
7
7

563
563
881
881
1350
1990

63.5
66.8
95.5
100.5
152.7
242.6

61.7
63.1
93.4
95.4
145.7
234.2

85
85
115
115
150
205

70
70
90
90
120
160

45
45
45
45
45
60

6
6
4
4
2
1/0

6/1
6/1
6/1
6/1
6/1
6/1

1190
1190
1860
1860
2850
4380

75.0
78.3
113.7
118.7
181.7
288.7

73.2
74.6
111.6
113.6
174.7
280.3

85
85
115
115
150
205

70
70
90
90
120
160

45
45
45
45
45
60

6
6
4
4
2
1/0

7
7
7
7
7
7

1110
1110
1760
1760
2800
4460

67.6
70.9
102.0
107.0
163.3
259.2

65.8
67.2
99.9
101.9
156.2
250.8

85
85
115
115
150
250

70
70
90
90
120
160

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

206
20160602

MULTIPLEX CABLES

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum Conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Triplex Overhead Service Drop


600V
Applications
To supply power from the utilitys lines to the consumers weatherhead. For service at 600V or less
(phase to phase) at a conductor temperature of 75C maximum for polyethylene Insulation or 90C
maximum for cross-linked insulation.

Standards
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76474

Item #

Phase
Conductor
Size
AWG

AAC Neutral Messenger


Haiotis
6
Patella
6
Fusus
4
Oyster
4
Clam
2
Murex
1/0
Purpura
1/0
Nassa
2/0
Melita
3/0
Portunus
4/0
Nannynose
336.4
Full Size ACSR Messenger
Paludina
6
Voluta
6
Whelk
4
Periwinkle
4
Conch
2
Neritina
1/0
Cenia
1/0
Runcina
2/0
Triton
2/0
Cherrystone
3/0
Mursia
3/0
Razor
4/0
Zuzara
4/0
Limpet
336.4

Phase
Conductor
Stranding

Phase
Conductor
Insulation
Thickness
(mil)

Bare
Neutral
Messenger
Size AWG

Bare
Neutral
Messenger
Stranding

Bare
Neutral
Messenger
Breaking
(lb)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Ampacity
XLP

Ampacity
Poly

Solid
7
Solid
7
7
7
19
7
19
19
19

45
45
45
45
45
60
60
60
60
60
80

6
6
4
4
2
1/0
1/0
2/0
3/0
4/0
336.4

7
7
7
7
7
7
7
7
19
19
19

563
563
881
881
1350
1990
1990
2510
3310
4020
6146

102.5
109.1
151.9
161.8
243.2
395.1
386.1
485.8
585.2
723.9
1160.4

98.8
101.6
147.6
151.7
229.2
369.4
369.4
455.3
562.9
697.3
1118.0

85
85
115
115
150
205
205
235
275
315
420

70
70
90
90
120
160
160
185
215
245
325

Solid
7
Solid
7
7
7
19
7
19
7
19
7
19
19

45
45
45
45
45
60
60
60
60
60
60
60
60
80

6
6
4
4
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
336.4

6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
18/1

1190
1190
1860
1860
2850
4380
4380
5310
5310
6620
6620
8350
8350
8680

114
120
169
176
267
530
426
530
526
656
650
814
805
1209

113
113
165
172
261
419
416
519
514
643
638
799
792
1167

85
85
115
115
150
205
205
235
235
250
250
315
315
420

70
70
90
90
120
160
160
185
185
200
200
245
245
325

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

207
20140921

MULTIPLEX CABLES

Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.

Aluminum Triplex Overhead Service Drop


600V

MULTIPLEX CABLES

Item #

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

ACSR Reduced Messenger


Scallop
4
Solid
Strombus
4
7
Cockle
2
7
Janthina
1/0
7
Ranella
1/0
19
Cavolinia
2/0
7
Clio
2/0
19
Sanddollar
3/0
7
Aega
3/0
19
Cuttlefish
4/0
7
Cerapus
4/0
19
Cowry
336.4
19
AAAC 6201 Alloy Neutral Messenger
Minex
6
Solid
Hippa
6
7
Prawn
4
Solid
Barnacles
4
7
Shrimp
2
7
Gammarus
1/0
7
Leda
1/0
19
Dungenese
2/0
7
Cyclops
2/0
19
Flustra
3/0
19
Lepas
4/0
19
AAAC 6201 Alloy Reduced Neutral Messenger
Artemia
4
Solid
Crab
4
7
Solaster
2
7
Sandcrab
1/0
7
Echinus
1/0
19
Crayfish
2/0
7
Sipho
2/0
19
Fulgar
3/0
19
Arca
4/0
19

Phase
Conductor
Insulation
Thickness
(mil)

Bare
Neutral
Messenger
Size AWG

Bare
Neutral
Messenger
Stranding

Bare
Neutral
Messenger
Breaking
(lb)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Ampacity
XLP

Ampacity
Poly

45
45
45
60
60
60
60
60
60
60
60
80

6
6
4
2
2
1
1
1/0
1/0
2/0
2/0
4/0

6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1

1190
1190
1860
2850
2850
3550
3550
4380
4380
5310
5310
8350

148
158
233
376
372
462
458
570
565
706
699
1135

144
148
227
365
362
451
446
557
552
691
684
1093

115
115
150
205
205
235
235
275
275
315
315
420

90
90
120
160
160
185
185
215
215
245
245
325

45
45
45
45
45
60
60
60
60
60
60

6
6
4
4
2
1/0
1/0
2/0
2/0
3/0
4/0

7
7
7
7
7
7
7
7
7
7
7

1110
1110
1760
1760
2800
4460
4460
5390
5390
6790
8560

106.6
113.2
158.4
168.3
253.7
411.7
402.7
506.8
495.3
611.4
757.1

102.9
105.7
154.1
158.2
239.7
386.0
386.0
476.3
476.3
589.1
730.5

85
85
115
115
150
205
205
235
235
275
315

70
70
90
90
120
160
160
185
185
215
245

45
45
45
60
60
60
60
60
60

6
6
4
2
2
1
1
1/0
2/0

7
7
7
7
7
7
7
7
7

1110
1110
1760
2800
2800
3530
3530
4460
5390

141.4
151.3
226.6
368.8
358.8
452.6
441.0
543.4
671.2

137.1
141.2
212.6
343.1
343.1
422.5
422.5
521.1
644.6

115
115
150
205
205
235
235
275
315

90
90
120
160
160
185
185
215
245

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
207
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Aluminum Quadruplex Overhead Service Drop


600V
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the users service head
where connection to the service entrance cable is made. To be used at voltages of 600V or less
phase to phase and at conductor temperatures not to exceed 75C for polyethylene insulated conductors or 90C for cross-linked polyethylene (XLP) insulated conductors.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76474.
Note
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB399 for 6201. Conductor temperature of 90C for XLR 75C for Poly; ambient temperatures of 40C;
emissivity 0.9; 2ft./sec ind in sun. To determine current ampacity by conductor size, please consult
The National Electric Code, latest edition.

Item #

Phase
Conductor
Size
AWG

AAC Neutral Messenger


Clydesdale
4
Pinto
4
Mustang
2
Criollo
1/0
Percheron
2/0
Hanoverian
3/0
Oldenburg
4/0
Lippizaner
336.4
ACSR Neutral Messenger
Morochuca
6
Chola
6
Morgan
4
Hackney
4
Palomino
2
Costena
1/0
Grullo
2/0
Suffolk
3/0
Appaloosa
4/0
Bronco
336.4
Gelding
336.4

Phase
Conductor
Stranding

Phase
Conductor
Insulation
Thickness
(mil)

Bare
Neutral
Messenger
Size AWG

Bare
Neutral
Messenger
Stranding

Bare
Neutral
Messenger
Breaking
(lb)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Ampacity
XLP

Ampacity
Poly

Solid
7
7
19
19
19
19
19

45
45
45
60
60
60
60
80

4
4
2
1/0
2/0
3/0
4/0
336.4

7
7
7
7
7
19
19
19

881
881
1350
1990
2510
3310
4020
6146

208
223
333
529
649
799
986
1546

201.8
207.9
312.6
504.5
620.5
765.6
946.7
1519.2

100
100
135
180
205
235
275
370

80
80
105
140
160
185
210
280

Solid
7
Solid
7
7
19
19
19
19
19
19

45
45
45
45
45
60
60
60
60
80
80

6
6
4
4
2
1/0
2/0
3/0
4/0
336.4
4/0

6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
18/1
6/1

1190
1190
1860
1860
2850
4380
5310
6620
8350
8580
8350

152
162
226
241
362
575
707
872
1079
1613
1548

147.4
151.7
220
226.1
342.6
550.6
678.7
838.9
1039.2
1568.2
1494.3

75
75
100
100
135
180
205
235
275
370
370

60
60
80
80
105
140
160
185
210
280
280

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

208
20140921

MULTIPLEX CABLES

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either
polyethylene or XLP cross-linked polyethylene. Neutral messengers are concentrically stranded
6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Aluminum Quadruplex Overhead Service Drop


600V

MULTIPLEX CABLES

Item #

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

AAAC 6201 Alloy Neutral Messenger


Bay
6
Solid
French Coach
6
7/w
German Coach
4
Solid
Arabian
4
7/w
Belgian
2
7/w
Shetland
1/0
19/w
Thoroughbred 2/0
19/w
Trotter
3/0
19/w
Walking
4/0
19/w

Phase
Conductor
Insulation
Thickness
(mil)

Bare
Neutral
Messenger
Size AWG

Bare
Neutral
Messenger
Stranding

Bare
Neutral
Messenger
Breaking
(lb)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Ampacity
XLP

Ampacity
Poly

45
45
45
45
45
60
60
60
60

6
6
4
4
2
1/0
2/0
3/0
4/0

7
7
7
7
7
7
7
7
7

1110
1110
1760
1760
2800
4460
5390
6790
8560

145
155
214
229
344
546
670
825
1019

140.0
144.3
208.3
214.4
323.1
521.1
641.5
791.8
979.7

75
75
100
100
135
180
205
235
275

60
60
80
80
105
140
160
185
210

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
208
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Copper Duplex Service Drop Cable


600V
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75C for polyethylene insulated conductors and 90C for cross-linked polyethylene (XLP) insulated conductors.
MULTIPLEX CABLES

Specifications
Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire
B-3 Soft or Annealed Copper Wire
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Theta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75C for polyethylene insulated conductors,90C for XLP insulated conductors, ambient temperature of 40C; 2
ft./sec. wind in sun.

Item #

Theta
Omega
Iota
Kappa
Lambda
Omicron
Sigma

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Cover
Thickness
(mil)

8
8
8
8
6
6
6

7
1
7
7
7
7
7

45
45
45
45
45
45
45

Neutral
Neutral
Neutral
Messenger Messenger Messenger
Size
Stranding
Rated
AWG
Strength
(lb)
10
8
8
8
8
6
6

1
1
1
7
1
1
7

529
826
826
777
826
1280
1228

Nominal
Lay
Length
(in)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Allowable
Ampacities
XLP

Allowable
Ampacities
Poly

10.36
10.36
10.36
10.36
10.36
10.36
10.36

96
112
115
116
149
179
180

97
113
116
117
149
179
181

85
85
85
85
110
110
110

70
70
70
70
90
90
90

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

227
20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper Triplex Service Drop Cable


600V
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75C for polyethylene insulated conductors and 90C for cross-linked polyethylene (XLP) insulated conductors.
MULTIPLEX CABLES

Specifications
Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire
B-3 Soft or Annealed Copper Wire
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Pica/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75C for polyethyl
ene insulated conductors, 90C for XLP insulated conductors, ambient temperature of 40C; 2
ft./sec. wind in sun.

Item #

Pica
Columbian
Bodoni
Garamond
Tudor
Futura
Gothic
Nonpareil
Ionic
Caslon
Minion
Primer
Century
Corinthian
Doric

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Cover
Thickness
(mil)

8
8
8
8
6
6
6
4
4
4
2
2
2
1/0
2/0

7
1
7
7
7
7
7
7
7
7
7
7
7
19
19

45
45
45
45
45
45
45
45
45
45
45
45
45
60
60

Neutral
Neutral
Neutral
Messenger Messenger Messenger
Size
Stranding
Rated
AWG
Strength
(lb)
10
8
8
8
8
6
6
6
4
4
4
4
2
1/0
2/0

1
1
1
7
1
1
7
1
1
7
1
7
7
7
7

529
826
826
777
826
1280
1228
1280
1970
1938
1970
1938
3050
4752
5926

Nominal
Lay
Length
(in)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Allowable
Ampacities
XLP

Allowable
Ampacities
Poly

10.36
10.36
10.36
10.36
14.88
14.88
14.88
14.88
14.88
14.88
20.58
20.58
20.58
20.58
25.42

160
174
179
180
246
276
278
381
429
432
594
596
674
1073
1342

149
164
167
169
232
262
263
363
411
413
571
574
651
1036
1301

85
85
85
85
110
110
110
145
145
145
195
195
195
265
300

70
70
70
70
90
90
90
115
115
115
155
155
155
205
235

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

228
20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper Quadruplex Service Drop Cable


600V
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75C for polyethylene insulated conductors and 90C for cross-linked polyethylene (XLP) insulated conductors.
MULTIPLEX CABLES

Specifications
Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire
B-3 Soft or Annealed Copper Wire
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Atlanta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75C for polyethylene insulated conductors,90C for XLP insulated conductors, ambient temperature of 40C; 2
ft./sec. wind in sun.

Item #

Atlanta
Tallahassee
Richmond
BatonRouge
Jackson
Seattle
Nashville
Lincoln
Raleigh
Denver

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Cover
Thickness
(mil)

6
6
4
4
2
2
1/0
2/0
3/0
4/0

7
7
7
7
7
7
19
19
19
19

45
45
45
45
45
45
60
60
60
60

Neutral
Neutral
Neutral
Messenger Messenger Messenger
Size
Stranding
Rated
AWG
Strength
(lb)
6
6
4
4
2
2
1/0
2/0
3/0
4/0

1
7
1
7
1
7
7
7
7
7

1280
1228
1970
1938
3003
3050
4752
5926
7366
9154

Nominal
Lay
Length
(in)

Weight
/MFT
XLP
(lb)

Weight
/MFT
Poly
(lb)

Allowable
Ampacities
XLP

Allowable
Ampacities
Poly

20.58
20.58
20.58
20.58
25.42
25.42
25.42
29.97
35.18
35.18

359
361
560
563
879
883
1405
1761
2209
2773

344
346
542
545
856
860
1368
1720
2163
2721

95
95
125
125
170
170
230
265
305
350

75
75
100
100
135
135
180
205
235
270

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

229
20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Single Secondary Type URD Cable


600V
Applications
Directly buried or installed in ducts for 600V secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90C conductor temperature, 20C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item #

Princeton
Mercer
Clemson
Kenyon
Harvard
Yale
Tufts
Beloit
Hofstra
Gonzaga
Rutgers
Emory
Duke
Furman
Sewanee
Fordham

Size AWG
or MCM

Stranding

Insulation
Thickness
(mil)

Outside
Diameter
(in)

Weight
/MFT
(lb)

Ampacity
Direct
Burial

Ampacity
In Duct

6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
500
600
700
750
1000

7
7
7
19
19
19
19
19
37
37
37
37
61
61
61
61

60
60
60
80
80
80
80
80
95
95
95
95
110
110
110
110

.298
.345
.403
.522
.482
.566
.616
.672
.748
.801
.851
.979
1.086
1.155
1.188
1.337

45
64
93
148
122
179
217
265
317
371
423
579
701
804
855
1109

90
120
155
200
175
225
250
290
320
355
385
465
510
550
580
670

65
85
115
150
130
170
195
225
250
280
305
370
410
440
470
545

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

209
201400921

MULTIPLEX CABLES

Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
USE-2 per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Duplex Secondary Type URD Cable


600 V
Applications
Directly buried or installed in ducts for 600V secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90C conductor temperature, 20C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item #

Bard
Claflin
Delgado
Everett

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Insulation
Thickness
(mil)

Neutral
Size
AWG

Neutral
Stranding

Neutral
Insulation
Thickness
(mil)

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
/MFT
Poly
(lb)

Ampacity
Direct
Burial

Ampacity
in Duct

8
6
4
2

7
7
7
7

60
60
60
60

8
6
4
2

7
7
7
7

60
60
60
60

.262
.299
.345
.403

.524
.596
.690
.806

76
91
129
189

70
95
125
187

70
70
90
100

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

210
20140921

MULTIPLEX CABLES

Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
USE-2 per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Triplex Secondary Type URD Cable


600 V
Applications
Directly buried or installed in ducts for 600V secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90C conductor temperature, 20C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item #

Erskine
Vassar
Stephens
Ramapo
Brenau
Bergen
Converse
Hunter
Hollins
Rockland
Sweetbriar
Monmouth
Pratt
Wesleyan
Holyoke
Rider
Fairfield

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Insulation
Thickness
(mil)

Neutral
Size
AWG

Neutral
Stranding

Neutral
Insulation
Thickness
(mil)

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
/MFT
Poly
(lb)

Ampacity
Direct
Burial

Ampacity
in Duct

6
4
2
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
350
500
500
750

7
7
7
7
19
19
19
19
19
19
19
19
37
37
37
37
61

60
60
60
60
80
80
80
80
80
80
80
80
95
95
95
95
110

6
4
4
2
2
1/0
1
2/0
1/0
3/0
2/0
4/0
3/0
4/0
300
350
500

7
7
7
7
7
19
19
19
19
19
19
19
19
19
37
37
37

60
60
60
60
60
80
80
80
80
80
80
80
80
80
95
95
95

.299
.345
.403
.403
.522
.522
.566
.566
.616
.616
.672
.672
.748
.851
.979
.979
1.188

.646
.754
.842
.874
1.064
1.133
1.174
1.228
1.276
1.336
1.389
1.457
1.538
1.736
2.008
2.035
2.0860

143
203
264
294
408
465
502
560
606
678
739
828
893
1166
1607
1663
2304

95
125
165
165
215
215
245
245
280
280
315
315
345
415
495
495
615

70
90
120
120
160
160
160
180
205
205
240
240
265
320
395
395
525

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

211
201400921

MULTIPLEX CABLES

Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.
B-901 Compressed round stranded Aluminum Conductors using single input wire construction.
Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
USE-2 per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Quadruplex Secondary Type URD Cable


600 V
Applications
Directly buried or installed in ducts for 600V secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
90C conductor temperature, 20C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item #

Tulsa
Dyke
Wittenberg
Notre Dame
Purdue
Syracuse
Lafayette
Swarthmore
Davidson
Wake Forest
Earlham
Slippery Rock
Wofford
Windham

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Insulation
Thickness
(mil)

Neutral
Size
AWG

Neutral
Stranding

Neutral
Insulation
Thickness
(mil)

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
/MFT
Poly
(lb)

Ampacity
Direct
Burial

Ampacity
in Duct

4
2
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
350
500
750

7
7
7
19
19
19
19
19
19
19
19
37
37
61

60
60
60
80
80
80
80
80
80
80
80
95
95
110

4
4
2
2
1/0
1
2/0
1/0
3/0
2/0
4/0
4/0
350
500

7/w
7/w
7/w
7/w
19/w
19/w
19/w
19/w
19/w
19/w
19/w
19/w
37/w
37/w

60
60
60
60
80
80
80
80
80
80
80
80
95
95

.345
.403
.403
.522
.522
.566
.566
.616
.616
.672
.672
.851
.851
.979

.833
.938
.973
1.188
1.260
1.316
1.367
1.430
1.487
1.560
1.623
1.945
2.348
2.850

258
346
375
541
596
664
720
805
874
979
1066
1544
2174
2542

119
153
153
198
198
225
225
250
250
290
290
385
467
615

85
115
115
150
150
170
170
195
195
225
225
305
420
492

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

212
20160603

MULTIPLEX CABLES

Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.
B-901 Compressed round stranded Aluminum Conductors using single input wire construction.
Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
USE-2 per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Mobile Home Feeder Type URD


600 V
Application
Mobile Home Feeder Cable is mainly used for supplying the energy required within the mobile
home. The cable is designed for use at 600V or less and conductor temperatures not exceeding
90C.

Marking
Manufacturer's ID plus E FILE NUMBER (SIZE AWG) AA-8000 AL TYPE USE-2 OR RHH OR RHW-2
SUN-RES 600V XLPE (UL) plus YEAR OF MANUFACTURE.
Sequential footage markings.
Installation
Suitable for direct burial or underground installations and in raceways.
Standards
Mobile Home Feeder cable meets or exceeds the following specifications:
ASTM B800 and B801 or B836 as applicable.
UL 44
UL 854
NEC requirements.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

Item #

2-2-2-4
2-5-4-6
2/0-2/0-2/0-1
2/0-2/0-4-1
4/0-4/0-4/0-2/0
4/0-4/0-2/0-4

Phase
Conductor
Size
AWG

Phase
Conductor
Const.

Phase
Conductor
Diameter
(in)

Neutral
Size
AWG

Neutral
Conductor
Const.

Neutral
Conductor
Diameter
(in)

Grounding
Conductor
Size AWG

Grounding
Conductor
Const.

Grounding
Conductor
Diameter
(in)

Diameter
Complete
Cable
(in)

Allowable
Ampacity

2
2
2/0
2/0
4/0
4/0

7
7
19
19
19
19

0.403
0.403
0.566
0.566
0.672
0.672

2
4
2/0
1
4/0
2/0

7
7
19
19
19
19

0.403
0.345
0.566
0.482
0.672
0.566

4
6
1
4
2/0
4

7
7
19
7
19
7

0.345
0.298
0.482
0.345
0.566
0.345

0.942
0.938
1.321
1.210
1.567
1.480

100
100
150
150
200
200

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

213
20140924

MULTIPLEX CABLES

Construction
Quadruplexed type USE-2 or RHH or RHW-2 compact stranded AA-8000 Series aluminum alloy conductors. Insulation is sunlight-resistant Cross-linked Polyethylene (XLPE). Neutral is identified by
triple extruded white stripes and Grounding is identified by total green surface coating.

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Packaging Information:
Duplex Service Drop
Aluminum Conductor
Code
Word

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)
6-7

Spaniel

4-7

500
2,800
500
2,000

32
179
48
192

33
185
50
198

Coil
NRC 30.18
Coil
NRC 30.18

1,000
3,300
500
2,000

75
248
58
230

77
254
59
234

Coil
NRC 38.18
Coil
NRC 30.18

Aluminum Alloy 6201-T81 Messenger


Vizsla
6-7
30580-7
500
2,800
Whippet
4-7
48690-7
500
2,000

34
190
52
206

35
196
53
210

Coil
NRC 30.18
Coil
NRC 30.18

4-7

ACSR Messenger
Shepherd
6-7

6-6/1

Terrier

4-6/1

4-7

MULTIPLEX CABLES

AAC Messenger
Collie
6-7

Reel
Size

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

214
20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Packaging Information:
Triplex Service Drop
Aluminum Conductor
Code
Word

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)
6-7

Oyster

4-7

4-7

Clam

2-7

2-7

Murex

1/0-7

1/0-7

Purpura

1/0-19

1/0-7

Nassa
Traphon
Quahog
Melita
Coquina
Portunus

210-7
2/0-19
3/0-7
3/0-19
4/0-7
4/0-19

2/0-7
2/0-7
3/0-7
3/0-19
4/0-7
4/0-19

1,000
2,200
500
1,500
500
1,800
500
1,200
500
1,200
1,500
1,500
1,300
1,300
1,000
1,000

104
229
77
230
116
418
187
448
185
444
692
684
741
735
707
699

107
235
79
237
119
428
192
460
190
456
708
701
758
750
722
713

Coil
NRC 30.18
Coil
NRC 38.18
Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 36.24
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26

1,000
2,200
4-6/1
500
1,500
2-6/1
500
1,800
1/0-6/1
500
1,200
1/0-6/1
500
1,200
2/0-6/1 1,500
2/0-6/1 1,500
3/0-6/1 1,300
3/0-6/1 1,300
4/0-6/1 1,000
4/0-6/1 1,000
336.4-18/1 1,000

115
253
86
238
131
470
210
503
208
499
779
771
836
829
799
792
1150

118
260
88
264
134
481
215
516
213
511
795
789
853
845
814
806
1180

Coil
NRC 30.18
Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 36.24
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26

ACSR Full Size Messenger


Voluta
6-7
6-6/1
Periwinkle

4-7

Conch

2-7

Neritina

1/0-7

Cenia

1/0-19

Runcina
Triton
Cherrystone
Mursia
Razor
Zuzara
Limpet

210-7
2/0-19
3/0-7
3/0-19
4/0-7
4/0-19
336.4-19

Code
Word

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)

AAAC-6201 Alloy Messenger


Hippa
6-7
30580-7

54
214
77
260
80
240
121
436
195
468
193
463
723
716
775
768
740
733

56
222
79
269
83
248
125
448
200
480
198
475
740
732
792
784
755
746

Coil
NRC 30.18
Coil
NRC 30.18
Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 36.24
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26

Aluminum Alloy 6201-T81 Reduced Size Messenger


Crab
4-7
30580-7
500
72
1,500
215
Solaster
2-7
48690-7
500
108
1,800
367
Sandcrab
1/0-7
77470-7
500
174
1,200
416
Echinus
1/0-19 77470-7
500
172
1,200
412
Crayfish
2/0-7
97633-7 1,500
641
Sipho
2/0-19 97633-7 1,500
635
Slub
3/0-7 123300-7 1,300
686
Fulgar
310-19 123300-7 1,300
680
Squid
4/0-7 155400-7 1,000
654
Arca
4/0-19 155400-7 1,000
647

74
222
111
400
179
428
177
424
659
651
703
696
669
661

Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 36.24
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26

Prawn

4-1

48690-7

Barnacle

4-7

48690-7

Shrimp

2-7

77470-7

Gammarus

1/0-7

123300-7

Leda

1/0-19 123300-7

Dungeness
Cyclops
Stonecrab
Flustra
Kingcrab
Lepas

2/0-7 155400-7
2/0-19 155400-7
3/0-7 195700-7
3/0-19 195700-7
4/0-7 246900-7
4/0-19 2469W-7

500
2,000
Soo
1,700
500
1,500
500
1,800
500
1,200
500
1,200
1,500
1,500
1,300
1,300
1,000
1,000

Reel
Size

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

215
20140110

MULTIPLEX CABLES

AAC Neutral Messenger


Patella
6-7

Reel
Size

Packaging Information:
Triplex Service Drop
Aluminum Conductor

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)
ACSR Reduced Size Messenger

MULTIPLEX CABLES

Code
Word

Stombus

4-7

6-6/1

Cockle

2-7

4-6/1

lanthina

1/0-7

2-6/1

Ranelia

1/0-19

2-6/1

Cavolinia
Clio
Sanddollar
Aega
Cuttlefish
Cerapus

2/0-7
2/0-19
3/0-7
3/0-19
4/0-7
4/0-19

1-6/1
1-6/1
1/0-6/1
1/0-6/1
2/0-6/1
2/0-6/1

500
1,500
500
1,800
500
1,200
500
1,200
1,500
1,500
1,300
1,300
1,000
1,000

76
228
114
409
183
438
181
434
677
669
724
718
691
684

78
233
117
419
188
451
186
446
693
687
741
735
706
699

Reel
Size

Coil
NRC 30.18
Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 36-24
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26
NRC 42.26

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
215
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Packaging Information:
Quadraplex Service Drop
Aluminum Conductor
Code
Word

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)
AAC Neutral Messenger
4-7

4-7

Mustang

2-7

2-7

Libyan

1/0-7

1/0-7

Criollo

1/0-19

1/0-7

Orloff

2/0-7

210-7

Percheron

2/0-19

2/0-7

Mongolian

310-7

3/0-7

Hanoverian

3/0-19

3/0-19

Singlefoot

4/0-7

4/0-7

Oldenberg

4/0-19

4/0-19

ACSR Messenger
Chola
6-7
Hackney

4-7

Palornino

2-7

Standardbred 1/0-7
Costena

1/0-19

Chicoteagues 2/0-7
Grullo

2/0-19

Mare

3/0-7

Suffolk

3/0-19

Stallion

4/0-7

Appaloosa

4/0-19

Bronco

336.4-19

6-6/1

500
1,500
500
1,800
550
1,100
550
1,100
750
1,500
750
1,500
650
1,300
650
1,300
500
1,000
500
1,000

500
2,100
4-6/1
500
1,500
2-6/1
500
1,800
1/0-6/1
550
1,100
110-6/1
550
1,200
2/0-6/1
750
1,500
210-6/1
750
1,500
310-6/1
650
1,300
3/0-6/1
650
1,300
4/0-6/-l
500
1,000
4/0-16/1
500
1,000
336.4-18/1 1,000

106
317
159
571
281
561
278
556
472
944
467
933
504
1009
499
998
481
961
475
950

77
322
115
344
173
623
306
612
303
606
515
1031
510
1,020
522
1,104
547
1,093
527
1,053
521
1,042
1510

109
327
163
587
288
576
286
572
485
969
479
959
517
1034
512
1,023
492
983
486
971

80
334
118
354
178
639
315
629
311
623
528
1056
523
1,046
565
1,130
559
1,118
538
1,075
532
1,063
1587

Coil
NRC 36.24
Coil
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 40.24
NRC 50.32
NRC 40.24
NRC 50.32

Code
Word

Aluminum Conductors
Standard Packages
Phase
Neutral Length
Weight
Size &
Size &
(ft)
Poly
XLP
Stranding Stranding
(lb)
(lb)
AAAC-6201 Alloy Neutral Messenger
French Coach 6-7

30580-7

Arabian

4-7

48690-7

Belgian

2-7

77470-7

Plow

110-7

123300-7

Shetland

1/0-19 123300-7

Dapple-Grey 2/0-7

155400-7

Thoroughbred 2/0-19 155400-7


Dobbin

3/0-7

195700-7

Trotter

3/0-19

195700-7

Pony

4/0-7

246900-7

Walking

4/0-19 246900-7

500
2,000
500
1,500
500
1,800
550
1,100
550
1,100
750
1,500
750
1,500
650
1,300
650
1,300
500
1,000
500
1,000

73
290
109
326
164
589
290
580
287
574
488
975
482
965
521
1,043
516
1,032
497
994
492
983

76
302
112
336
169
607
298
596
295
591
500
1001
495
990
534
1,069
528
1,057
508
1,016
502
1004

Reel
Size

Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 40.24
NRC 50.32
NRC 40.24
NRC 50.32

Coil
NRC 36.24
Coil
NRC 36.24
Coil
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 42.26
NRC 36.24
NRC 50.32
NRC 36.24
NRC 50.32
NRC 36.24,
NRC 50.32
NRC 36.24
NRC 50.32
NRC 40.24
NRC 50.32
NRC 40.24
NRC 50.32
NRC 50.32

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

216
20140110

MULTIPLEX CABLES

Pinto

Reel
Size

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Packaging Information:
Secondary
Type URD Cable
Code
Word

Aluminum Conductor
Standard Packages
Size
Stranding Length
Weight
Reel
AWG or
(ft)
(lb)
Size
Cir. Mils

1,000
7,000
1,000
5,000
1,000
5,000
1,000
5,500
1,000
4,800
1,000
1,000
4,100
1,000
1,000
1,000
1,000
1,000

98
686
131
655
157
785
189
1,040
229
1,100
278
278
1,140
336
448
611
902
1,166

NRC 24.12
NRC 36.24
NRC 24.12
NRC 36.24
NRC 24.12
NRC 40.24
NRC 24.18
NRC 42.26
NRC 24.18
NRC 42.26
NRC 24.18
NRC 30.15
NRC 42.26
NRC 30.18
NRC 32.24
NRC 36.24
NRC 40.24
NRC 42.26

Quadruplex Conductor Type URD Cable


Tulsa
4-7
4-7
1,000
1,500
Dyke
2-7
4-7
1,000
1,400
1,500
Wittenberg
2-7
2-7
1,000
1,400
1,500
Notre Dame 1/0-19
2-7
1,000
1,400
1,500
Purdue
1/0-19
1/0-19
1,000
1,400
1,500
Syracuse
2/0-19
1-19
1,000
1,400
1,500
Lafayette
2/0-19
2/0-19
1,000
Wake Forest 4/0-19
2/0-19
1,000
1,400
1,500
Farlham
4/0-19
4/0-19
1,000
1,500
Slippery Rock 350-37
4/0-19
1,000
1,400

258
387
346
484
519
375
525
563
541
757
812
596
834
894
664
930
996
720
979
1371
1469
1066
1599
1544
2162

NRC 32.24
NRC 34.26
NRC 32.24
NRC 40.24
NRC 40.24
NRC 32.24
NRC 40.24
NRC 40.24
NRC 40.24
NRC 48.28
NRC 48.28
NRC 42.26
NRC 48.28
NRC 48.28
NRC 42.26
NRC 50.32
NRC 50.32
NRC 42.28
NRC 50.32
NRC 54.32
NRC 54.32
NRC 50.32
NRC 54.32
NRC 60.28
NRC 66.28

Kenyon

19

Harvard

1/0

19

Yale

210

19

Tufts

3/0

19

Beloit

4/0

19

250000
350000
500000
750000
1000000

37
37
37
61
61

Hoistra
Rutgers
Emory
Sewanee
Fordham

Aluminum Conductor
Standard Packages
Size
Stranding Length
Weight
Reel
AWG or
(ft)
(lb)
Size
Cir. Mils

Triplex Conductor Type URD Cable


Stephens
2-7
4-7
Brenau
1/0-19
2-7
Converse
2/0-19
1-19
Hollins
3/0-19
1/0-19
Sweetbriar 4/0-19
2/0-19
Pratt
250000-37 3/0-19
Wesleyan 350000-37 4/0-19
Rider
500000-37 350000-37

1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000

262
409
504
609
740
896
1,168
1,606

NRC 32.24
NRC 36.24
NRC 40.24
NRC 42.26
NRC 42.26
NRC 50.32
NRC 50.32
NRC 58.32

Triplex Conductor Type URD Cable


Ramapo
2
2-7
Bergen
1/0
1/0-19
Hunter
210
2/0-19
Rockland
3/0
3/0-19
Monmouth
4/0
4/0-19

1,000
1,000
1,000
1,000
1,000

291
465
561
680
827

NRC 32.24
NRC 40.24
NRC 40.24
NRC 42.26
NRC 45.28

Also available master reel lengths up to 20,000 ft. We custom cut to any
length you need.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

217
20140902

MULTIPLEX CABLES

Single Conductor Type URD Cable


Clemson
2
7

Code
Word

MULTIPLEX CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

LOW VOLTAGE CABLES


Table of Contents
TowerGuard CCA 2kV RHH or RHW-2 ................................................................................201
Aluminum XLP UL XHHW-2 90 600V..................................................................................205
Aluminum XLP UL RHH/RHW-2 or USE-2 90C 600V .........................................................204
TowerGuard Aluminum XLP UL RHH/RHW-2 or USE-2 90C 2kV....................................202
Towerguard Plus Class 33 Aluminum XLPE 105C 2kV ....................................................240
SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 600V ..................................230
SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 2kV ....................................225
SunGuardTM Duplexed Aluminum XLPE UL Type PV Photovoltaic Wire 2kV....................234
Copper PVC UL THW-2 75C 600V ........................................................................................219
Copper PVC UL TFFN/TFN 90C 600V...................................................................................226
UF-B Underground Feeder 600V ..........................................................................................220
Copper XLP UL XHHW-2 600V..............................................................................................222
Copper XLP Type SIS VW-1 90C 600V ................................................................................221
Copper XLP UL RHH/RHW-2 or USE-2 90C 600V...............................................................223
SunGuardTM Copper XLPE UL Type PV Photovoltaic Wire 600V ........................................203
Copper EPR/CPE UL RHH/RHW-2 or USE-2 90C 600V .......................................................224
Copper XLP UL RHH/RHW-2 or USE-2 90C 2kV .................................................................233
DLO Copper EPR/CPE UL TRJJ/RHW-2 2kV..........................................................................709
SunGuardTM Copper XLPE Type PV Photovoltaic Wire 2kV ...............................................231
LSZH XLPO/LSZH XLPO UL Type RHH/RHW-2/USE-2 Unshielded 600V ...........................241
SunGuardTM Tracker Motor Cable UL Type PV/TC 2kV ........................................................239

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

200
20150108

LOW VOLTAGE CABLES

Copper PVC/Nylon UL THHN/THWN-2 90C Dry 75C Wet 600V ........................................218

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TowerGuard CCA Power Cable


2kV UL RHH/RHW-2 Copperclad Aluminum Conductor/90C Wet or Dry
For Cable Tray Use Sunlight Resistant For Direct Burial
U.S. Patent No. 8,618,688

Construction
Nominal voltage: RHH/RHW-2 2000V UL
Conductor: The conductor shall be a flexible
Copperclad Aluminum (CCA), an electrical conductor that has an outer sleeve of copper metallurgically bonded to a solid aluminum core. The
combination of these two metals makes it
uniquely suited to many electrical applications
where weights to electrical conductivity issues
are important. This bimetallic wire is much
lighter than copper and only slightly heavier
than bare aluminum. The density of CCA is
about 35% lighter than copper. CCA conducts
like copper for AC frequencies. This product
meets or exceeds the minimum requirements
set forth in ASTM B 566 04.
Separator: A suitable tape separator between
the conductor and insulation.
Insulation: Ethylene-propylene rubber (EPR)
type EP, meeting UL and ICEA requirements for
90C.
Jacket: A heavy duty, thermosetting CPE in accordance with ICEA S-95-658 NEMA WC70
Jacket Color: Black
Print Legend: TOWERGUARD CCA SIZE AWG
OR KCMIL) CU CLAD AL UL 217923 RHH or
RHW-2 2000V SUN RES OIL RES U.S. Patent No.
8,618,688 (SEQUENTIAL FOOTAGE MARKER)

Specifications
ICEA S-95-658 / NEMA WC70
UL Standard 44
ASTM B 566
ASTM B 172
Product Features
35% less expensive than copper cables with
equal ampacity
Flexible cable design TowerGuard RHH or
RHW-2 can bend to a radius of 6 times the
O.D. without impairing the insulation.
Surface printed for easy identification
35% lighter weight and easier to install than
copper cables with equal ampacity
Ozone, sunlight, oil, grease, weather, water,
chemical and abrasion resistant jacket
90C (dry) 90C (wet)
No scrap value (theft deterrent)
Sequential footage markers
U.S. Patent No. 8,618,688
Terminals and Splices
Testing has been competed using TowerGuard
CCA with BURNDY aluminum HYLUGTM terminals an HYLINKTM splices. Both are UL Listed
for use on copperclad aluminum cable.
Wire

CCA4/0
CCA250
CCA350
CCA500
CCA600
CCA750
CCA800
CCA900
CCA1000

Size

4/0awg
250kcmil
350kcmil
500kcmil
600kcmil
750kcmil
750kcmil
900kcmil
1000kcmil

BURNDY LUG PART NUMBER


1 hole
2 hole
Butt
Splice
YA30A1 YA30A3 YS30A1
YA31A1 YA31A3 YS31A1
YA34A1 YA34A3 YS34A1
YA36A1 YA36A3 YS36A1
YA39A1 YA39A5 YS39A1
YA44A1 YA44A3 YS44A1
YA44A1 YA44A3 YS44A1
YA45A5 YS45A1
YA45A5 YS45A1

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

201
201400924

LOW VOLTAGE CABLES

Applications
This cable is intended for fixed installation in
wind turbine towers. Good resistance to temperatures, oils, ozone and fire. This cable is intended for use in solar power generation
applications to connect the inverter to transformer where high flexibility is required, commonly applied to prefabricated inverter and
transformer skids. Additionally, this cable is appropriate for tight battery applications, as well
as superior alternatives to battery cable. TowerGuard CCA can also be used for secondary voltage resistance welding leads and in power
supply applications not exceeding 2000V volts.
Not commonly for use on DC power circuits,
please consult AWG for your applications.

NOTES

LOW VOLAGE CABLES

Item #

Conductor Stranding Nominal Nominal Nominal


Size
Conductor Insulation Jacket
AWG/kcmil
Diameter Thickness Thickness
(in)
(mil)
(mil)

CCA4/0-01TWRGRD
4/0
CCA250-01TWRGRD
250
CCA350-01TWRGRD
350
CCA500-01TWRGRD
500
CCA600-01TWRGRD
600
CCA750-01TWRGRD
750
CCA800-01TWRGRD
800
CCA900-01TWRGRD
900
CCA1000-01TWRGRD 1000

329
399
551
779
925
1184
1258
1406
1554

0.584
0.650
0.764
0.909
0.993
1.124
1.158
1.225
1.288

65
75
75
75
90
90
90
90
90

45
65
65
65
65
65
65
65
65

Nominal
Cable
Diameter
(in)

Copper
Weight
/MFT
(lb)

Aluminum
Weight
/MFT
(lb)

Net
Cable
Weight
/MFT
(lb)

Ampacity*
90C
Free Air

Ampacity**
90C
Duct

0.802
0.930
1.044
1.189
1.273
1.434
1.468
1.535
1.598

96
116
161
227
270
345
367
416
453

165
200
277
391
464
595
632
706
780

458
590
756
1017
1301
1462
1521
1733
1850

315
355
455
545
615
700
725
785
845

205
230
280
350
385
435
450
480
500

*Ampacity is calculated based on a single conductor in free air with a 90C conductor temperature and 30C ambient, per 2008 NEC, Table 310-17
**Ampacity is calculated based on 3 conductors in a duct with a 90C conductor temperature and 30C ambient, per 2008 NEC, Table 310-16

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum XLP UL
XHHW-2 600V
90C Wet or Dry
Applications
Type XHHW-2 is intended for use as general purpose wiring in air conduit or other recognized raceways for services, feeder and branch circuit wiring as specified in the National Electric Code at a
maximum conductor temperature of 90C in wet or dry locations.
Construction
Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat and moisture resistant cross-linked polyethylene insulation.
Standards
UL 44
Federal specifications JC-30B NEC, ASTM B 800, B 801, B 836 as applicable.
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

XHHW-2-0008
XHHW-2-0006
XHHW-2-0004
XHHW-2-0002
XHHW-2-0001
XHHW-2-01/0
XHHW-2-02/0
XHHW-2-03/0
XHHW-2-04/0
XHHW-2-0250
XHHW-2-0300
XHHW-2-0350
XHHW-2-0400
XHHW-2-0500
XHHW-2-0600
XHHW-2-0700
XHHW-2-0750
XHHW-2-1000

Size AWG
or MCM

Stranding

Insulation
Thickness
(mil)

Outside
Diameter
(in)

Weight
/MFT
(lb)

Ampacity
90C

8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
1000

7
7
7
7
18
18
18
18
18
35
35
35
35
35
58
58
58
58

45
45
45
45
55
55
55
55
55
65
65
65
65
65
80
80
80
80

.230
.260
.305
.360
.415
.450
.490
.540
.590
.655
.705
.750
.795
.870
.980
1.040
1.075
1.230

29
40
58
86
109
132
162
199
245
294
347
398
450
552
672
774
825
1077

45
60
75
100
115
135
150
175
205
230
255
280
305
350
385
420
435
500

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

205
20140921

LOW VOLTAGE CABLES

Item #

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum XLP UL
RHH/RHW-2 or USE-2 600V
90C Wet or Dry
Applications
Type RHH-RHW-2 or USE-2 building wire and service cable is recognized for use as general purpose
wiring at a maximum conductor temperature of 90C in wet or dry locations for installation in air,
conduit or other recognized raceways and for direct burial in circuits not exceeding 600V.
Construction
Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat, moisture and sunlight resistant cross-linked polyethylene insulation.
Standards
UL Standards 44 (RHW or RHH)
UL standard 854 (USE-2)
Federal specification JC-30B NEC
ASTM B800, B801, B836 as applicable.

Item #

USE-RHH-RHW-2-0008
USE-RHH-RHW-2-0006
USE-RHH-RHW-2-0004
USE-RHH-RHW-2-0002
USE-RHH-RHW-2-0001
USE-RHH-RHW-2-01/0
USE-RHH-RHW-2-02/0
USE-RHH-RHW-2-03/0
USE-RHH-RHW-2-04/0
USE-RHH-RHW-2-0250
USE-RHH-RHW-2-0300
USE-RHH-RHW-2-0350
USE-RHH-RHW-2-0400
USE-RHH-RHW-2-0500
USE-RHH-RHW-2-0600
USE-RHH-RHW-2-0700
USE-RHH-RHW-2-0750
USE-RHH-RHW-2-1000

Size AWG
or MCM

Stranding

Insulation
Thickness
(mil)

Outside
Diameter
(in)

Weight
/MFT
(lb)

Ampacity
90C

8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
1000

7
7
7
7
18
18
18
18
18
35
35
35
35
35
58
58
58
58

60
60
60
60
80
80
80
80
80
95
95
95
95
95
110
110
110
110

.266
.290
.334
.390
.460
.500
.540
.590
.635
.710
.760
.810
.850
.930
1.035
1.100
1.130
1.280

37
49
65
94
125
150
181
220
268
320
374
428
482
591
715
821
873
1132

45
60
75
100
115
135
150
175
205
230
255
280
305
350
385
420
435
500

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

204
20140921

LOW VOLTAGE CABLES

Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TowerGuard Aluminum XLP UL


RHH/RHW-2 or USE-2 2kV
90C
Applications
For use from the lower control box at the base
of the wind power tower and out to the stepup transformer through conduit
General purpose building wire for use in air
and approved raceways
Industrial environments where superior insulation toughness and chemical resistance is
required
Maximum operating temperature not to exceed 90C in wet or dry locations
For use in free air, raceways or direct burial in
accordance with NEC.

Insulation:
Flame-retardant Cross-Linked Polyethylene
(XLPE) Black
Print:
TOWERGUARD XLP AWG/KCMIL TYPE
RHH/RHW-2 SR CT (UL) 2000V (MM/YYYY)
SEQUENTIAL FOOTAGE MARK
Sizes smaller than 1/0 AWG do not include the
CT marking

Item #

TGXL-08
TGXL-06
TGXL-04
TGXL-02
TGXL-01
TGXL-1/0
TGXL-2/0
TGXL-3/0
TGXL-4/0
TGXL-250
TGXL-350
TGXL-500
TGXL-600
TGXL-750
TGXL-1000

Features
Rated at 90C wet or dry
UV resistant black is marked SR
Excellent electrical, thermal and physical
properties
Excellent resistance to moisture
Excellent resistance to crush, compression
cuts and heat deformation
Packaging
All produced or cut-to-order material will be
shipped on non-returnable wooden reels unless specifically requested
Cable is stocked in 3 colors - Black with 3 Red
Stripes, Black with 3 Yellow Stripes, Black with
3 Orange Stripes.

Conductor
Size
AWG/kcmil

No. of
Wires1

Conductor
Diameter
(in)

Insulation
Thickness
(mil)

Cable
Diameter
(in)

Aluminum
Weight
/MFT
(lb)

Net
Weight
/MFT
(lb)

Ampacity
90C

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
600
750
1000

7
7
7
7
18
18
18
18
18
35
35
35
58
58
58

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.616
0.736
0.813
0.908
1.060

70
70
70
70
90
90
90
90
90
105
105
105
120
120
120

0.285
0.320
0.360
0.420
0.495
0.530
0.580
0.615
0.665
0.745
0.840
0.960
1.075
1.175
1.325

16
25
39
62
79
99
125
158
199
235
329
471
565
706
941

38
51
72
100
134
160
192
229
281
336
449
605
736
901
1168

45
60
75
100
115
135
150
175
205
230
280
350
385
435
500

Dimensions and weights are nominal; subject to industry tolerances.


1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

202
20151123

LOW VOLTAGE CABLES

Product Construction
Conductor:
8 AWG thru 1000 kcmil compacted aluminum
ACM (AA-8000 Series)

Compliances
National Electric Code (NEC)
UL 44 Stranded for rubber-insulated wires and
cables
CT for 1/0 AWG and larger in accordance
with NEC
ICEA S-95-685/NEMA WC70
UL listed as Type RHH/RHW-2
OSHA acceptable

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Towerguard Plus
Class 33 Aluminum XLPE 105C 2kV
Applications
For use from the lower control box at the base
of the wind power tower and out to the stepup transformer through conduit
General purpose building wire for use in air
and approved raceways
Industrial environments where superior insulation toughness and chemical resistance is
required
Maximum operating temperature not to exceed 105 C in wet or dry locations
For use in free air, raceways or direct burial in
accordance with NEC.

Item #

A4/0-01XLP2BLK105
A500-01XLP2BLK105
A750-01XLP2BLK105
A1000-01XLP2BLK105

Features
Rated at 105 C wet or dry
UV resistant - black is marked SR
Smaller cable O.D.
Excellent electrical, thermal and physical
properties
Excellent resistance to moisture
Excellent resistance to crush, compression
cuts and heat deformation
Packaging
Material can be produced and cut to length
upon request
All produced or cut-to-order material will be
shipped on non-returnable wooden reels unless specifically requested

Conductor
Size
AWG or kcmil

Number of
Wires1

Conductor
Diameter
(in)

Insulation
Thickness
(mil)

Cable
Diameter
(in)

Aluminum
Weight
(lb/MFT)

Net
Weight
(lb/MFT)

4/0
500
750
1000

18
35
58
58

0.475
0.736
0.908
1.060

90
105
120
120

0.665
0.960
1.175
1.325

199
471
706
941

281
605
901
1168

Dimensions and weights are nominal: subject to industry tolerances.


1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

240
20151123

LOW VOLTAGE CABLES

Construction
Conductor: 8 AWG thru 1000 kcmil compacted
aluminum ACM (AA-8000 Series) Conductor. Insulation is Class 33 Flame-retardant CrossLinked Polyethylene (XLPE) Black.
Colors: Black, Red, Blue, Green, Orange, Yellow
Brown. 3 extruded stripes and other colors are
available upon request.
Print Legend:TOWERGUARD PLUS
AWG/KCMIL AL XLPE 2000V 105 C (MM/YYYY)
SEQUENTIAL FOOTAGE MARK

Standards
UL 1581
ICEA S-95-685/NEMA WC70
CSA standard C 22.2 No. 38

LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SunGuard Aluminum XLPE UL Type PV Photovoltaic Wire 600V


UL Type PV/USE-2 or 2kV RHH or RHW-2 or c(UL) RWU90, 1kV, 90C
Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90C wet or dry, 600 V for interconnection wiring of grounded and
ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC),
NFPA 70.
For use in free air, raceways or direct burial in
accordance with NEC.

Options
Colored phase ID stripes available on request
Multi-plexing available on request

Item #

Conductor
Size
(AWG/
kcmil)
8 AWG - 1000 kcmil CONDUCTORS
A8-01PVX0700*
8
A6-01PVX0700*
6
A4-01PVX0700*
4
A2-01PVX0700*
2
A1-01PVX1900*
1
A1/0-01PVX190*
1/0
A2/0-01PVX1900*
2/0
A3/0-01PVX1900*
3/0
A4/0-01PVX1900*
4/0
A250-01PVX3700*
250
A300-01PVX3700*
300
A350-01PVX3700*
350
A400-01PVX3700*
400
A500-01PVX3700*
500
A600-01PVX6100*
600
A750-01PVX6100*
750
A1000-01PVX6100*
1000

Conductor
Stranding

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

Nominal
Conductor O.D.
(in)
(mm)

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

3.40
4.29
5.41
6.81
7.59
8.53
9.55
10.74
12.07
13.21
14.48
15.65
16.74
18.69
20.65
23.06
26.92

Minimum Average
Insulation Thickness
(in)
(mm)

0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.110
0.125
0.125
0.125

2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
2.79
3.18
3.18
3.18

Compliances
UL 4703 Type PV
National Electrical Code (NEC)
ICEA S-95-658/NEMA WC70
UL 44 Type RHH or RHW-2
UL 854 Type USE-2
c(UL) RWU90 1 kV
UL 1581 VW-1 For sizes 1/0 and larger: IEEE
383, IEEE 1202/CSA FT4
Packaging
Material cut to length and shipped on non-returnable wood reels.

Nominal Cable
Diameter
(in)
(mm)

0.298
0.333
0.377
0.432
0.495
0.532
0.572
0.619
0.671
0.746
0.796
0.842
0.885
0.962
1.069
1.164
1.316

7.57
8.46
9.58
10.97
12.57
13.51
14.53
15.72
17.04
18.95
20.22
21.39
22.48
24.43
27.15
29.57
33.43

Aluminum
Weight
/MFT
/km
(lb)
(Kg)

Net
Weight
/MFT
/km
(lb)
(Kg)

16
25
39
63
79
99
125
158
199
262
282
329
376
471
565
706
914

49
64
85
117
153
180
214
256
307
399
430
487
544
656
798
963
1210

23
37
58
93
117
148
186
235
296
390
420
490
560
701
841
1051
1360

73
95
127
174
227
268
318
380
456
594
640
725
810
977
1187
1433
1801

Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

230
20151123

LOW VOLTAGE CABLES

Construction
Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Print: AWG (PLANT OF MFG) SUNGUARD
600 V PV WIRE OR USE-2 OR 2000 V RHH OR
RHW-2 (SIZE) AL ACM 90C WET OR DRY SUN
RES (UL) -40C VW-1 c(UL) RWU90 1000 V DIR
BUR MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Features
Rated 90C wet and dry
Deformation-resistant at high temperatures
Excellent moisture resistance, exceeds UL 44
Stable electrical properties over a broad temperature range
Excellent resistance to crush and compression
cuts
Resistant to most oils and chemicals
UV/sunlight-resistant
Meets cold bend test at -40C

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SunGuard Aluminum XLPE UL Type PV Photovoltaic Wire 2kV


UL Type PV/RHH or RHW-2 or 600V USE-2 or c(UL) RWU90, 1kV 90C
Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90C wet or dry, 2000 V for interconnection wiring of grounded and
ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC),
NFPA 70.
For use in free air, raceways or direct burial in
accordance with NEC.

Options
Colored phase ID stripes available on request
Multi-plexing available on request

Item #

Conductor
Size
(AWG/
kcmil)
8 AWG - 1000 kcmil CONDUCTORS
A8-01PV2X0700*
8
A6-01PV2X0700*
6
A4-01PV2X0700*
4
A2-01PV2X0700*
2
A1-01PV2X1900*
1
A1/0-01PV2X190*
1/0
A2/0-01PV2X1900*
2/0
A3/0-01PV2X1900*
3/0
A4/0-01PV2X1900
4/0
A250-01PV2X3700
250
A300-01PV2X3700
300
A350-01PV2X3700
350
A400-01PV2X3700
400
A500-01PV2X3700
500
A600-01PV2X6100*
600
A750-01PV2X6100*
750
A1000-01PV2X6100* 1000

Conductor
Stranding

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

Nominal
Conductor O.D.
(in)
(mm)

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

3.40
4.29
5.41
6.81
7.59
8.53
9.55
10.74
12.07
13.21
14.48
15.65
16.74
18.69
20.65
23.06
26.92

Minimum Average
Insulation Thickness
(in)
(mm)

0.085
0.085
0.085
0.085
0.105
0.105
0.105
0.105
0.105
0.120
0.120
0.120
0.120
0.120
0.135
0.135
0.135

2.16
2.16
2.16
2.16
2.67
2.67
2.67
2.67
2.67
3.05
3.05
3.05
3.05
3.05
3.43
3.43
3.43

Compliances
UL 4703 Type PV
National Electrical Code (NEC)
ICEA S-95-658/NEMA WC70
UL 44 Type RHH or RHW-2
UL 854 Type USE-2
c(UL) RWU90 1 kV
UL 1581 VW-1 For sizes 1/0 and larger: IEEE
383, IEEE 1202/CSA FT4
Packaging
Material cut to length and shipped on non-returnable wood reels.

Nominal Cable
Diameter
(in)
(mm)

0.310
0.345
0.389
0.444
0.515
0.552
0.592
0.639
0.691
0.766
0.816
0.862
0.905
0.982
1.089
1.184
1.336

7.87
8.76
9.88
11.28
13.08
14.02
15.04
16.23
17.55
19.46
20.73
21.89
22.99
24.94
27.66
30.07
33.93

Aluminum
Weight
/MFT
/km
(lb)
(Kg)

Net
Weight
/MFT
/km
(lb)
(Kg)

16
25
39
63
79
99
125
158
199
262
282
329
376
471
565
706
914

52
67
90
122
162
191
225
267
319
413
445
503
561
675
818
985
1235

23
37
58
93
117
148
186
235
296
390
420
490
560
701
841
1051
1360

78
100
133
182
241
284
334
398
475
615
663
749
835
1004
1217
1466
1838

Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

225
20160104

LOW VOLTAGE CABLES

Construction
Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Print: AWG (PLANT OF MFG) SUNGUARD
2000 V PV WIRE OR RHH OR RHW-2 OR 600 V
USE-2 (SIZE) AL ACM 90C WET OR DRY SUN
RES (UL) -40C VW-1 c(UL) RWU90 1000 V DIR
BUR MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Features
Rated 90C wet and dry
Deformation-resistant at high temperatures
Excellent moisture resistance, exceeds UL 44
Stable electrical properties over a broad temperature range
Excellent resistance to crush and compression
cuts
Resistant to most oils and chemicals
UV/sunlight-resistant
Meets cold bend test at -40C

LOW VOLAGE CABLES

SunGuard Aluminum XLPE UL Type PV Photovoltaic Wire


Type PV/RHH or RHW-2 2kV or 600V USE-2
AA8000
Maximum Electrical Resistivity
Temperature 20
AWG size
/1000ft
8
1.07
7
0.8495
6
0.674
5
0.5346
4
0.4238
3
0.3361
2
0.2665
1
0.2113
1/0
0.1676
2/0
0.1329
3/0
0.1055
4/0
0.836
250kmil
0.07076
300
0.05897
350
0.05054
400
0.04423
450
0.03931
500
0.03537
550
0.03216
600
0.02948
700
0.02527
750
0.02358
800
0.02211
900
0.01966
1000
0.01769

/1000m
3.515
2.787
2.211
1.754
1.39
1.103
0.8745
0.6934
0.5498
0.4361
0.3459
0.2743
0.2322
0.1935
0.1659
0.145
0.1289
0.1161
0.1055
0.09673
0.08291
0.07738
0.07254
0.06448
0.05804

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
225
20160104

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

SunGuard Duplexed Aluminum XLPE UL


Type PV Photovoltaic Wire 2kV
Applications
Duplexed conductors are sunlight-resistant,
photovoltaic wire rated 90C wet or dry, 2000
volts for interconnection wiring of grounded
and ungrounded photovoltaic power systems as
described in Section 690.31(A) and other applicable parts of the National Electrical Code
(NEC), NFPA 70.
For use in free air, raceways or direct burial in
accordance with NEC.

Item #

A8-02PV2X0700
A6-02PV2X0700
A4-02PV2X0700
A2-02PV2X0700
A1-02PV2X1900
A1/0-02PV2X190
A2/0-02PV2X1900
A3/0-02PV2X1900
A4/0-02PV2X1900
A250-02PV2X3700
A300-02PV2X3700
A350-02PV2X3700
A400-02PV2X3700
A500-02PV2X3700
A600-02PV2X6100
A750-02PV2X6100
A1000-02PV2X6100

Standards
Rated 90C wet and dry
Deformation-resistant at high temperatures
Excellent moisture resistance, exceeds UL 44
Stable electrical properties over a broad temperature range
Excellent resistance to crush and compression
cuts
Resistant to most oils and chemicals
UV/sunlight-resistant
Meets cold bend test at -40C
Material cut to length and shipped on non-returnable wood reels.

Conductor
Size
(AWG/kcmil)

Single
Conductor
Stranding

Nominal
Conductor
OD
(in)

Minimum
Average
Insulation
Thickness
(in)

Duplexed
Cable
Diameter
(in)

Aluminum
Weight
(lb/MFT)

Net
Weight
(lb/MFT)

8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7/.0486
7/.0612
7/.0772
7/.0974
19/.0664
19/.0745
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

0.134
0.169
0.213
0.268
0.299
0.336
0.376
0.423
0.475
0.520
0.570
0.616
0.659
0.736
0.813
0.908
1.060

0.085
0.085
0.085
0.085
0.105
0.105
0.105
0.105
0.105
0.120
0.120
0.120
0.120
0.120
0.135
0.135
0.135

0.62
0.69
0.78
0.89
1.03
1.10
1.18
1.28
1.38
1.53
1.63
1.72
1.81
1.96
2.18
2.37
2.67

32
50
78
126
158
198
250
316
398
524
564
658
752
942
1130
1412
1828

104
134
180
244
324
382
450
534
638
826
890
1006
1122
1350
1636
1970
2470

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

234
20151123

LOW VOLTAGE CABLES

Construction
Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) conductors. Insulation is Flame-Retardant Cross-Linked
Polyethylene (XLPE), black, suitable for 2000 V.
Print Legend: AWG (PLANT OF MFG) SUNGUARD 2000 V PV WIRE OR RHH OR RHW-2
OR 600 V USE-2 (SIZE) AL ACM 90C WET OR
DRY SUN RES (UL) -40 C VW-1 c(UL) RWU90
1000 V DIR BUR MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK
Duplexing: One phase conductor is black, the
other conductor is black with three white
stripes. Conductors are pre-twisted together on
reel.

Features
Rated 90C wet and dry
Deformation-resistant at high temperatures
Excellent moisture resistance, exceeds UL 44
Stable electrical properties over a broad temperature range
Excellent resistance to crush and compression
cuts
Resistant to most oils and chemicals
UV/sunlight-resistant
Meets cold bend test at -40C
Use Duplex SunGard to avoid mismatch of
Positive and Negative sets
Reduce labor costs and equipment cost for
laying cable in trench by deploying one reel,
instead of two

LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper PVC UL THW-2


75C 600V
Application
Single conductor general purpose wiring for lighting and power. The product is insulated with
polyvinylchloride (PVC), and dual rated as UL Types TW and THW. It is intended for use in accordance with the NEC in residential, commercial and industrial applications not exceeding 600V
and/or 75C in wet or dry locations.
Construction
Single conductor copper insulated with polyvinylchloride (PVC), solid or stranded, tinned or bare
soft annealed copper per ASTM B-3, B-8 and complying with the physical and electrical requirements of UL standards 83 and 1851.
Identified by surface marking indicating manufacturers identification, conductor size, voltage rating, and UL Type TW and THW designations.

Item #

THW-C14S
THW-C12S
THW-C10S
THW-C14
THW-C12
THW-C10
THW-C8
THW-C6
THW-C4
THW-C3
THW-C2
THW-C1
THW-C1/0
THW-C2/0
THW-C3/0
THW-C4/0
THW-C250
THW-C300
THW-C350
THW-C400
THW-C500

Size AWG
or MCM

Number of
Strands

Insulation
Thickness
(mil)

Approximate
O.D.
(in)

Amapcity
3/C in
Raceway

Shipping
Weight
/MFT
(lb)

14
12
10
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500

Solid
Solid
Solid
7
7
7
7
7
7
7
7
19
19
19
19
19
37
37
37
37
37

45
45
45
45
45
45
60
60
60
60
60
80
80
80
80
80
95
95
95
95
95

0.16
0.18
0.20
0.17
0.19
0.21
0.20
0.31
0.36
0.39
0.42
0.49
0.53
0.58
0.63
0.69
0.77
0.82
0.87
0.95
1.01

15
20
30
15
20
30
50
65
85
100
115
130
150
175
200
230
255
285
310
335
380

22
31
45
24
33
48
77
112
167
202
252
324
397
491
608
753
896
1060
1227
1391
1715

LOW VOLTAGE CABLES

Standards
Underwriters Lab standard 83 for thermoplastic insulated wires.
Underwriters Lab standard 1581 for wires, cables, and cords.
ICEA S-95-658/NEMA WC70
Federal Specification JC-30B

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

219
20140110

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper PVC UL TFFN/TFN


90C 600V
Applications
For internal wiring of fixtures, fixture raceways, fire alarm circuits in raceways.
Construction
Conductor is fully Annealed bare copper per ASTM B-3 and B-174.
Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride).
Jacket is tough polyamide nylon.
VW-1 Flame Test rated.
Gasoline and Oil Resistant II
Resistant to abrasion, acids, alkalines, ozone and water.

Item #

TFFN-C18
TFFN-C16
TFN-C18S
TFN-C16S

Conductor
Size
AWG

Number of
Strands

Approx.
O.D.
(in)

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Shipping
Weight
/MFT
(lb)

18
16
18
16

16
26
Solid
Solid

0.088
0.101
0.088
0.101

15
15
15
15

4
4
4
4

8
12
8
12

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

226
20140921

LOW VOLTAGE CABLES

Standards
ASTM B-3 and B-174.
UL Standard 62 for fixture wire.
UL Standard 1063 for machine tool wire
NY State DOS 16120-880926-2008
OSHA acceptable
NFPA 70 (NECR)
NFPA 79 AWM 600V 105C (75C in oil).

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper PVC/Nylon UL THHN/THWN-2


90C Dry or 75C Wet 600V
Application
General purpose building wire for services, feeders and branch circuits. Suitable for use in conduit
and raceways; 1/0 and larger for cable tray use.
Construction
Conductor is bare annealed copper per ASTM B-3.
Stranded conductors per ASTM B-8.
Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride).
Jacket is tough polyamide nylon.
VW-1 AWG rated through 4/0 AWG.
1/0 AWG and larger rated for CT use.
1/0 AWG and larger rated Sunlight Resistant.
Gasoline and Oil Resistant II.
Resistant to abrasion, acids, alkalines, ozone, and water.

Item #

THHN-C14S
THHN-C12S
THHN-C10S
THHN-C14
THHN-C12
THHN-C10
THHN-C8
THHN-C6
THHN-C4
THHN-C3
THHN-C2
THHN-C1
THHN-C1/0
THHN-C2/0
THHN-C3/0
THHN-C4/0
THHN-C250
THHN-C300
THHN-C350
THHN-C400
THHN-C500
THHN-C600
THHN-C750
THHN-C1000

LOW VOLTAGE CABLES

Standards
ASTM B-3 and B-8
UL Standard 83 THHN/THWN-2
UL Standard 1581 for machine tool wire
ICEA S-95-658/NEMA WC70
Federal Specification JC-30B
OSHA acceptable
NFPA 70 (NECR)
NFPA 79 AWM 600V 105C (75C in oil).

Size AWG
or MCM

Number of
Strands

Insulation
Thickness
(mil)

Nylon
Jacket
Thickness
(mil)

Approximate
O.D.
(in)

Amapcity
75C
Wet

Ampacity
90C
Dry

Shipping
Weight
/MFT
(lb)

14
12
10
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

Solid
Solid
Solid
19
19
19
19
19
19
19
19
19
19
19
19
19
37
37
37
37
37
61
61
61

15
15
20
15
15
20
30
30
40
40
40
50
50
50
50
50
50
60
60
60
60
70
70
70

4
4
4
4
4
4
5
5
6
6
6
7
7
7
7
7
7
8
8
8
8
9
9
9

0.102
0.118
0.150
0.110
0.128
0.161
0.212
0.250
0.318
0.345
0.375
0.430
0.470
0.515
0.565
0.620
0.730
0.780
0.830
0.880
0.970
1.060
1.170
1.300

20
25
30
20
25
35
50
65
85
100
115
130
150
175
200
230
255
285
310
335
380
420
475
545

25
30
40
25
30
35
55
75
95
105
130
150
170
195
225
260
290
320
350
380
430
475
535
615

17
25
39
18
27
40
69
109
166
202
254
316
398
488
603
731
903
1058
1211
1332
1735
1990
2428
3263

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

218
20140925

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

UF-B
Copper Underground Feeder
600V 75C
Applications
For direct burial, for use in dwellings not exceeding 3 floors above grade, as underground feeder to
outdoor lighting or apparatus, or as general branch circuit wiring. Recognized for use as exposed or
concealed wiring in damp, moist, wet, dry, and corrosive locations. For use as new wiring or as replacement wiring.
Construction
Conductor is bare annealed copper per ASTM B-3 or stranded conductors, per ASTM B-8.
Insulation is color coded PVC (polyvinyl chloride) with a nylon jacket.
Type THHN inners, rated 90C.
Ampacity is limited to that for 60C conductors per NECR Articles 336 and 339.
Jacket is gray PVC (polyvinyl chloride).
Color code 2 conductor: black, white; 3 conductor: black, white, red.

Item #

UFB-1
UFB-2
UFB-3
UFB-4
UFB-5
UFB-6
UFB-7
UFB-8
UFB-9
UFB-10
UFB-11
UFB-12
UFB-13
UFB-14
UFB-15
UFB-16
UFB-17
UFB-18

Constr./
Size AWG

Number of
Strands

Ground
Wire
Size

Approximate
O.D.
(in)

Shipping
Weight
/MFT
(lb)

14/2
12/2
10/2
14/3
12/3
10/3
8/3
6/3
14/2
12/2
10/2
8/2
6/2
14/3
12/3
10/3
8/3
6/3

Solid
Solid
Solid
Solid
Solid
Solid
7
7
Solid
Solid
Solid
7
7
Solid
Solid
Solid
7
7

(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
14
12
10
10
10
14
12
10
10
10

.20 x .39
.21 x .42
.23 x .46
.20 x .57
.21 x .62
.23 x .68
.34 x .96
.40 x 1.20
.21 x .40
.22 x .43
.24 x .47
.32 x .62
.41 x .81
.20 x .57
.21 x .62
.23 x .68
.34 x .96
.40 x 1.20

60
79
107
97
130
173
284
467
79
107
148
246
358
111
151
207
317
501

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

220
20140110

LOW VOLTAGE CABLES

Standards
Listed under UL Standard 493.
Federal Specification JC-30B.
ASTM B-3 and B-8

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper XLP UL XHHW-2


600V 90C Wet or Dry
Applications
Single conductor crosslinked polyethylene (XLP or XLPE) Type XHHW-2, intended for use at 600
volts or less. It is approved for general purpose lighting and power applications at a maximum continuous operating temperature of 90C in wet or dry locations. VW-1 available where required.
Construction
Single copper conductors, solid or stranded annealed or hard uncoated copper per UL83 and ASTM
requirements. Insulates with XLP as specified and applied tightly to the conductor in a concentric
manner. The mimimum at any point shall not be less than 90% of the specified average thickness in
compliance with UL 44. Identified by surface marking indicating the manufacturer, conductor size,
voltage rating, UL symbol, and type designation. Continuously spark tested at 7500 Volts DC and
pass the 4 hour cold bend test of -25C. Other electrical and mechanical tests shall be in accordance
with UL 44 and UL 1581.

Item #

XHHW-C14
XHHW-C12
XHHW-C10
XHHW-C8
XHHW-C6
XHHW-C4
XHHW-C3
XHHW-C2
XHHW-C1
XHHW-C1/0
XHHW-C2/0
XHHW-C3/0
XHHW-C4/0
XHHW-C250
XHHW-C300
XHHW-C350
XHHW-C400
XHHW-C500
XHHW-C600
XHHW-C750
XHHW-C1000

LOW VOLTAGE CABLES

Standards
Underwriters Laboratories UL 44
Canadian Standard C22.2 No. 38
Insulated Cable Engineers Association ICEA S-95-658
Institute of Electrical and Electronics Engineers IEEE 1202
Federal Specification A-A-59544
NEMA Publication No. WC-70
Gas and Oil Resistant II (UL)

Size
AWG or
MCM

Number of
Strands

Insulation
Thickness
(mil)

Approximate
O.D.
(in)

Copper
Weight
/MFT
(lb)

Shipping
Weight
/MFT
(lb)

Ampacity
90C
Dry

14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7/19
7/19
7/19
7
7
7
7
7
19
19
19
19
19
37
37
37
37
37
61
61
61

30
30
30
45
45
45
45
45
55
55
55
55
55
65
65
65
65
65
80
80
80

0.140
0.160
0.180
0.240
0.280
0.330
0.349
0.390
0.450
0.490
0.535
0.590
0.645
0.715
0.770
0.820
0.870
0.955
1.040
1.150
1.300

12.7
20.2
32.1
51.0
81.1
128.9
162.5
204.9
258.4
325.8
410.9
518.1
653.3
771.9
926.3
1081.0
1235.0
1544.0
1853.0
2316.0
3008.0

18
27
41
67
100
153
190
236
292
363
452
562
702
831
1000
1160
1322
1643
1982
2461
3257

15
20
30
55
75
95
110
130
150
170
195
225
260
290
320
350
N/A
430
475
535
615

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

222
20140921

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper XLP Type SIS VW-1


90C 600V
Applications
Single conductor cross-linked polyethylene (XLP or XLPE) Type SIS-VW-1 for use at 600V or less.
Approved per NEC Article 384 for instrument and control wiring where wiring is required to pass
the UL vertical flame test. Rated for a maximum continuous operating temperature of 90C in wet or
dry locations.

Standards
Tin-coated, soft annealed copper per ASTM B-33, Class B stranding ASTM B-8
ICEA S-95-658/NEMA WC-70
UL 44 for Thermoset Insulated Wires & Cables
Fed Spec J-C-30B

Item #

SIS-1-18
SIS-2-16
SIS-3-14
SIS-4-12
SIS-5-10
SIS-6-8
SIS-7-6
SIS-8-4
SIS-9-2
SIS-10-1
SIS-11-1/0

Size
AWG

Number of
Strands

Optional
Stranding

Insulation
Thickness
(mil)

Nominal
Overall
Diameter
(in)

Shipping
Weight
/MFT
(lb)

18
16
14
12
10
8
6
4
2
1
1/0

16
26
41
65
105
133
133
133
133
133
133

7, 19
7, 19
7, 19
7, 19
7, 19
7, 19
7, 19
7, 19
7, 19
19, 37
19, 37

30
30
30
30
30
45
45
45
45
55
55

.09 / .10
.11 / .12
0.13 / 0.14
0.15 / 0.16
0.17 / 0.18
0.24 / 0.25
0.28 / 0.30
0.32 / 0.34
0.38 / 0.40
0.44 / 0.48
0.48 / 0.52

11
15
21
27
40
75
115
175
250
330
400

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

221
20140921

LOW VOLTAGE CABLES

Construction
Stranded conductor, annealed, coated copper per UL83 and ASTM requirements.
Insulated with XLP as specified and applied tightly to the conductor in a concentric manner.
Conductors are Oil and Gas Resistant II.
The standard color is gray; other colors available.
All black insulation is rated Sunlight Resistant.
The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44.
Identified by surface marking indicating manufacturers identification, conductor size, voltage rating, and UL symbol, VW-1, and type designation.
Continuously spark tested at 7500V DC and pass the 4 hour cold bend test at -25C. Other electrical and mechanical tests shall be in accordance with UL 44 and UL 1581.

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper XLP UL RHH/RHW-2 or USE-2


90C 600V
Applications
Single conductor cross-linked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600V or
less. It is approved per the NEC for general purpose lighting and power applications at a maximum
continuous operating temperature of 90C in wet and dry locations. Suitable for direct burial.
Construction
The single copper conductors shall be solid or stranded annealed or hard uncoated copper per
UL83 and ASTM requirements. Insulated with XLP as specified and applied tightly to the conductor
in a concentric manner. All black insulation is rated Sunlight Resistant. The minimum at any point
shall not be less than 90% of the specified average thickness in compliance with UL 44. The wire
shall be identified by surface marking indicating the manufacturer, conductor size, voltage rating,
UL symbol, and type designation. The wire shall be continuously spark tested at 7500V DC. Other
electrical and mechanical tests shall be in accordance with UL44, UL 854 and UL 1581.

Item #

USE2-C14
USE2-C12
USE2-C10
USE2-C8
USE2-C6
USE2-C4
USE2-C3
USE2-C2
USE2-C1
USE2-C1/0
USE2-C2/0
USE2-C3/0
USE2-C4/0
USE2-C250
USE2-C300
USE2-C350
USE2-C400
USE2-C500
USE2-C600
USE2-C750
USE2-C1000

Size
AWG or
MCM

Number of
Strands

Insulation
Thickness
(mil)

Approximate
O.D.
(in)

Copper
Weight
/MFT
(lb)

Shipping
Weight
/MFT
(lb)

Ampacity
90C
Dry

14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

7
7
7
7
7
7
7
7
19
19
19
19
19
37
37
37
37
37
61
61
61

45
45
45
60
60
60
60
60
80
80
80
80
80
95
95
95
95
95
110
110
110

0.16
0.17
0.20
0.27
0.31
0.37
0.39
0.43
0.51
0.56
0.60
0.66
0.72
0.80
0.86
0.91
0.94
1.05
1.16
1.27
1.44

12.7
20.2
32.1
51.0
81.1
128.9
162.5
204.9
258.4
325.8
410.9
518.1
653.3
771.9
926.3
1081.0
1235.0
1544.0
1853.0
2316.0
3008.0

22
31
45
74
108
161
198
244
319
392
484
599
743
889
1053
1217
1379
1703
2056
2540
3343

15
20
30
55
75
95
110
130
150
170
195
225
260
290
320
350
380
430
475
535
615

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

223
20140110

LOW VOLTAGE CABLES

Standards
ASTM B-1, B-3 and B-8 for copper conductors
ICEA S-95-658/NEMA WC70
UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44
for Thermoset Insulated Wires & Cables
Fed Spec J-C-30B

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SunGuard Copper XLPE UL Type PV Photovoltaic Wire


UL Type PV/RHH or RHW-2 600V or 600V USE-2
Applications
For use in grounded and ungrounded Photovoltaic power systems
Construction
Stranded bare and tinned copper conductors
per ASTM B-3, B-8.
Chemically Cross-linked Polyethylene insulation.
Available Colors: Black, Green, White, Red.
Print on one side with a contrasting ink. An extruded stripe and other colors are available
upon request.

Industry Listings & Standards


Industry Compliances
UL 4703 Type PV
National Electrical Code (NEC)
ICEA S-95-658/NEMA WC70
UL 44 Type RHH or RHW-2
UL 854 Type USE-2 for 600 V
c(UL) RWU90 1 kV (-40C)
Flame Test Compliances
UL 1581 VW-1
For sizes 1/0 and larger: IEEE 383, IEEE
1202/CSA FT4

Item #

AWG

Stranding

PV-600-18
PV-600-16
PV-600-14
PV-600-12
PV-600-10
PV-600-08
PV-600-06
PV-600-04
PV-600-02
PV-600-01
PV-600-1/0
PV-600-2/0
PV-600-3/0
PV-600-4/0
PV-600-250
PV-600-300
PV-600-350
PV-600-400
PV-600-500
PV-600-600
PV-600-750
PV-600-1000

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0092
19/.0117
19/.0142
19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

Nominal Nominal Minimum Minimum Nominal


Conductor Conductor Average Average
Cable
O.D.
O.D.
Insulation Insulation Diameter
(in)
(mm)
(in)
(mm)
(in)
0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.110
0.125
0.125
0.125

1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
2.79
3.18
3.18
3.18

0.169
0.180
0.194
0.214
0.238
0.307
0.348
0.398
0.460
0.515
0.563
0.608
0.658
0.714
0.784
0.837
0.887
0.932
1.015
1.122
1.224
1.373

Nominal
Cable
Diameter
(mm)

Copper
Weight
(lb/MFT)

Copper
Weight
(kg/km)

Net
Weight
(lb/MFT)

Net
Weight
(kg/km)

4.29
4.57
4.93
5.43
6.04
7.80
8.84
10.11
11.68
13.08
14.30
15.44
16.71
18.13
19.91
21.26
22.53
23.67
25.78
28.50
31.09
34.87

5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

14
18
27
36
51
85
123
180
267
333
410
502
620
767
923
1090
1240
1423
1718
2136
2597
3411

21
27
40
54
76
126
183
268
397
495
610
747
922
1141
1374
1622
1845
2117
2557
3179
3865
5076

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

203
201400921

LOW VOLTAGE CABLES

Other Compliances
EPA 40 CFR, Part 261 for leachable lead content per TCLP
OSHA Acceptable
RoHS Compliant

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper EPR/CPE RHH/RHW-2 or USE-2


90C 600V
Applications
Recommended for use in all low voltage circuits where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, directly buried in the earth, or lashed to a messenger for aerial installation. These
cables may also be installed in cable tray (size 1/0 AWG and larger per NEC 392.2).
Specifications
Conductor: Uncoated copper solid per ASTM-B-3, compress stranded per ASTM B-8, or compact per
ASTM B-496.
Insulation: Meets or exceeds all requirements of ICEA S-95-658/NEMA WC-70 and UL Standards 44
and 854.
Jacket: CSPE. Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2 or USE-2, VW-1. Sizes
1/0 AWG and larger are also marked sunlight resistant, for use in cable tray.
Listed by CSA as RW-90, -25C, FT1 (1/0 and larger FT4), outdoor.

Notes
These ampacities are based on single conductor in free air, 40C ambient air temperature, 90C conductor operating temperature.
Options
PVC or LSOH jacket

Item #

Conductor
Size
AWG or
MCM

USE2-14
14 AWG
USE2-12
12 AWG
USE2-10
10AWG
USE2-8
8 AWG
USE2-6
6 AWG
USE2-4
4 AWG
USE2-2
2 AWG
USE2-1/0
1/0 AWG
USE2-2/0
2/0 AWG
USE2-4/0
4/0 AWG
USE2-250 250 MCM
USE2-350 350 MCM
USE2-500 500 MCM
USE2-750 750 MCM
USE2-1000 1000MCM

Conductor Conductor Nominal


Stranding Diameter Insulation
(in)
(in)
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61

0.072
0.091
0.116
0.146
0.183
0.231
0.292
0.373
0.419
0.528
0.575
0.681
0.813
0.980
1.152

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

Min.
(in)

Nominal Jacket Thickness


Min.
Approx. Approx.
Max.
Max.
(mm)
(in)
(mm)
(in)
(mm)

0.161
0.185
0.205
0.268
0.335
0.382
0.441
0.559
0.602
0.717
0.827
0.929
1.055
1.264
1.413

4.10
4.70
5.20
6.80
8.50
9.70
11.20
14.20
15.30
18.20
21.00
23.60
26.80
32.10
35.90

0.165
0.189
0.213
0.276
0.346
0.394
0.453
0.575
0.619
0.736
0.850
0.957
1.088
1.303
1.457

4.20
4.80
5.40
7.00
8.80
10.0
11.50
14.60
15.73
18.70
21.60
24.30
27.64
33.10
37.0

0.177
0.205
0.228
0.299
0.374
0.425
0.488
0.622
0.669
0.795
0.917
1.031
1.177
1.406
1.575

4.50
5.20
5.80
7.60
9.50
10.80
12.40
15.80
17.00
20.20
23.30
26.20
29.90
35.70
40.00

Nominal
O.D.
(in)

Approx.
Weight
/MFT
(lb)

Ampacity
40C
Ambient
Temp.

0.236
0.256
0.290
0.333
0.403
0.461
0.510
0.700
0.740
0.870
0.990
1.055
1.125
1.205
1.305

24
34
49
79
124
179
260
420
513
774
956
1290
1798
2686
3463

25
32
47
83
109
145
192
258
298
400
445
552
695
898
1076

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

224
20140110

LOW VOLTAGE CABLES

Product Features
Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in
cable tray.
Passes the IEEE 383-1974 Vertical Tray Flame Test.
Passes the IEEE 1202-1991 Vertical Tray Flame Test. (sizes 1/0 AWG & larger).
Extreme heat resistance; 90C continuous rating, wet or dry 110C hot spot rating 130C emergency overload rating 250C short circuit rating

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper XLP UL RHH/RHW-2 or USE-2


90C 2kV
Application
Type RHH, RHW-2 is suitable for wiring in raceways, conduit, etc. Applications include general
purpose wiring for power distribution, services,
feeders, and branch circuit wiring in residential,
industrial, and commercial buildings.
For use in free air, raceways or direct burial in
accordance with NEC.

Item #

14-01XLP2000
12-01XLP2000
10-01XLP2000
8-01XLP2000
6-01XLP2000
4-01XLP2000
3-01XLP2000
2-01XLP2000
1-01XLP2000
1/0-01XLP2000
2/0-01XLP2000
3/0-01XLP2000
4/0-01XLP2000
250-01XLP2000
300-01XLP2000
350-01XLP2000
400-01XLP2000
500-01XLP2000
600-01XLP2000
750-01XLP2000

Stranding

Size
AWG
or
KCMIL

Insulation
Thickness
(mil)

Nominal
Overall
Diameter
(in)

Approximate
Net Weight
(lb/MFT)

Ampacity*
90C
Wet/Dry

7
7
7
7
7
7
7
7
19
19
19
19
19
37
37
37
37
37
61
61

14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750

60
60
60
80
80
80
80
80
95
95
95
95
95
110
110
110
110
110
125
125

0.193
0.212
0.236
0.306
0.344
0.392
0.420
0.452
0.511
0.550
0.594
0.644
0.700
0.795
0.849
0.901
0.948
1.033
1.143
1.248

27
37
51
83
120
175
212
259
330
404
497
613
758
909
1,074
1,239
1,402
1,728
2,084
2,571

35
40
55
80
105
140
165
190
220
260
300
350
405
455
500
570
615
700
780
885

*Based on ambient temperature of 30C per NEC-Table 310-17


The overcurrent protection for items marked with an obelisk () shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per
NEC 310-17 footnote.
Data shown is approximate and subject to standard industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

233
20151123

LOW VOLTAGE CABLES

Construction
Conductor: Single copper conductor, stranded
Insulation: Heat resistant cross-linked polyethylene. Temperature rating is 90C in wet and dry
applications
Packaging: All produced or cut-to-order material
will be shipped on non-returnable wooden reels
unless specifically requested.

Standards
ASTM B3, B8 and B787
UL 44 ICEA S-95-658/NEMA WC-70
For CT use 1/0 AWG and larger
Gasoline and Oil Resistant II
-40C rated to 90C in wet and dry applications
C(UL) US RWU90 1kV:CSA/UL Listed
C(UL) RPVU90 1kV
Sunlight Resistant
RoHS Compliant

LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

DLO Copper EPR/CPE UL


RHH/RHW-2 2kV
Applications
This cable is for wiring down tower applications and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor
and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs.
Construction
Conductor is extra flexible tinned, stranded copper with a separator layer.
EPR insulation.
Jacket is CPE (Hypalon jacket available upon request).
Standards
Meets flame test requirements of MSHA and passes ICEA cold bend test at -40C.
Meets AAR specifications.
UL listed as RHH-RHW-2.
Rated for CT use, 1/0 and larger.

Item #

Area
Circular
(mil)

Size
AWG

Number of
Strands in
Conductor

Insulation
Thickness
(in)

Jacket
Thickness
(mil)

Overall
Diameter
(in)

Net Weight
/MFT
(lb)

Ampacity
1/C Free Air
90C

DL-600/2-1
DL-600/2-2
DL-600/2-3
DL-600/2-4
DL-600/2-5
DL-600/2-6
DL-600/2-7
DL-600/2-8
DL-600/2-9
DL-600/2-10
DL-600/2-11
DL-600/2-12
DL-600/2-13
DL-600/2-14
DL-600/2-15
DL-600/2-16
DL-600/2-17
DL-600/2-18
DL-600/2-19
DL-600/2-20
DL-600/2-21
DL-600/2-22

3831
6088
10910
14950
24640
36760
42420
60600
90900
111100
131300
181800
222200
262600
313100
373700
444400
535300
646400
777700
929200
1111000

14
12
10
8
6
5
4
2
1
1/0
2/0
3/0
4/0
262.6
313.1
373.7
444.4
535.3
646.4
777.7
929.2
1111.0

19
19
27
37
61
91
105
150
225
275
325
450
550
650
775
925
1100
1325
1591
1924
2299
2745

.045
.045
.045
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.090
.090
.090
.090
.110
.110
.110
.110
.110

30
30
30
30
30
30
30
30
45
45
45
45
45
65
65
65
65
65
65
65
65
65

.24
.25
.29
.33
.40
.43
.45
.50
.64
.69
.73
.80
.86
.97
1.01
1.11
1.18
1.29
1.38
1.47
1.58
1.74

34
45
68
82
125
175
195
265
425
500
570
780
890
1100
1280
1500
1760
2110
2410
2930
3450
4130

32
36
55
83
109
127
145
192
223
258
298
345
400
458
514
574
642
725
815
910
1025
1143

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

709
20140921

LOW VOLTAGE CABLES

Notes
Ampacity based on single conductor in free air, 90C conductor temperature, 40C ambient per
ICEAS-75-381.
Sequential footage marks.
Shipping tolerance +/- 10%

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SunGuard Copper XLPE UL Type PV Photovoltaic Wire


Type PV/RHH 2kV or 600kV USE-2
Applications
Appropriate for use in solar power applications
that require 1000 or 2000 volt rating. For use in
grounded and ungrounded Photovoltaic power
systems.
For use in free air, raceways or direct burial in
accordance with NEC.

Item #

AWG

Stranding

PV-2000-18
PV-2000-16
PV-2000-14
PV-2000-12
PV-2000-10
PV-2000-08
PV-2000-06
PV-2000-04
PV-2000-02
PV-2000-01
PV-2000-1/0
PV-2000-2/0
PV-2000-3/0
PV-2000-4/0
PV-2000-250
PV-2000-300
PV-2000-350
PV-2000-400
PV-2000-500
PV-2000-600
PV-2000-750
PV-2000-1000

18
16
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19/.0092
19/.0117
19/.0142
19/.0185
19/.0234
19/.0295
19/.0372
19/.0469
19/.0526
19/.0664
19/.0740
19/.0837
19/.0940
19/.1055
37/.0822
37/.0900
37/.0972
37/.1040
37/.1159
61/.0992
61/.1109
61/.1280

Nominal Nominal Minimum Minimum Nominal


Conductor Conductor Average Average
Cable
O.D.
O.D.
Insulation Insulation Diameter
(in)
(mm)
(in)
(mm)
(in)
0.045
0.056
0.070
0.088
0.112
0.143
0.184
0.234
0.296
0.323
0.370
0.410
0.460
0.520
0.558
0.611
0.661
0.706
0.789
0.866
0.968
1.117

1.14
1.42
1.78
2.23
2.84
3.63
4.67
5.94
7.52
8.20
9.40
10.41
11.68
13.21
14.17
15.52
16.79
17.93
20.04
22.00
24.59
28.37

0.075
0.075
0.075
0.075
0.075
0.085
0.085
0.085
0.085
0.105
0.105
0.105
0.105
0.105
0.120
0.120
0.120
0.120
0.120
0.135
0.135
0.135

1.90
1.90
1.90
1.90
1.90
2.16
2.16
2.16
2.16
2.67
2.67
2.67
2.67
2.67
3.05
3.05
3.05
3.05
3.05
3.43
3.43
3.43

0.199
0.210
0.224
0.244
0.268
0.326
0.363
0.406
0.474
0.538
0.586
0.631
0.674
0.737
0.804
0.857
0.907
0.952
1.035
1.142
1.244
1.393

Flame Test Compliances


UL 1581 VW-1
For sizes 1/0 and larger: IEEE 383, IEEE
1202/CSA FT4
Other Compliances
EPA 40 CFR, Part 261 for leachable lead content per TCLP
OSHA Acceptable
RoHS Compliant

Nominal
Cable
Diameter
(mm)

Copper
Weight
(lb/MFT)

Copper
Weight
(kg/km)

Net
Weight
(lb/MFT)

Net
Weight
(kg/km)

5.05
5.33
5.69
6.20
6.81
8.28
9.22
10.31
12.04
13.66
14.88
16.03
17.12
18.72
20.42
21.77
23.04
24.18
26.29
29.01
31.60
35.38

5
8
13
20
32
50
81
129
205
258
326
411
518
653
772
926
1063
1235
1509
1883
2316
3088

7
12
19
30
48
74
121
192
305
384
485
611
771
972
1149
1378
1582
1838
2246
2802
3447
4595

16
21
32
42
57
87
123
181
266
350
429
527
647
796
938
1106
1257
1441
1737
2157
2620
3437

24
31
48
62
85
129
183
269
396
521
638
784
963
1184
1396
1646
1870
2144
2585
3211
3900
5115

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

231
20151123

LOW VOLTAGE CABLES

Construction
Stranded bare and tinned copper conductors
per ASTM B-3, B-8.
Chemically Cross-linked Polyethylene insulation.
Available Colors: Black, Green, White, Red.
Print on one side with a contrasting ink. An extruded stripe and other colors are available
upon request.

Industry Listings & Standards


Industry Compliances
UL 4703 Type PV
National Electrical Code (NEC)
ICEA S-95-658/NEMA WC70
UL 44 Type RHH or RHW-2
UL 854 Type USE-2 for 600 V
c(UL) RWU90 1 kV (-40C)

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

LSZH XLPO/LSZH XLPO


Low-Voltage Power, Unshielded 600 V
UL Type RHH/RHW-2/USE-2
Applications
For use in closed environments or populated
spaces such as auditoriums, arenas and health
facilities where more stringent customer specifications for smoke and halogen-free materials
are desired. Ideally suited for use in a broad
range of commercial, industrial and utility applications where reliability is a major concern,
where maximum performance will be demanded
and where space is limited. For use in free air,
raceways or direct burial in accordance with NEC.

Features
Rated at 90C wet or dry
Low-Smoke, Zero-Halogen insulation system
Extra-tough, mechanically rugged composite
insulation construction
Low friction for easy pulling on 8 AWG and
larger
Excellent electrical, thermal and physical
properties
Excellent moisture resistance, exceeding UL
44 requirements
Excellent resistance to crush, compression
cuts and heat deformation
Excellent flame resistance

Item#

14-01XLSOH
12-01XLSOH
10-01XLSOH
8-01XLSOH
6-01XLSOH
4-01XLSOH
2-01XLSOH
1/0-01XLSOH
2/0-01XLSOH

Compliances
National Electrical Code (NEC)
FOR CT USE on 1/0 AWG and larger in accordance with NEC
UL 44 Type RHH/RHW-2
UL 854 Type USE-2
Limited Smoke rating per UL 44 and UL 1685
Compressed tinned copper per ASTM B33
Class B stranding per ASTM B8
ICEA T-33-655 smoke, halogen and acid gas requirements
ICEA S-95-658/NEMA WC70
Flame Test Compliances
For 1/0 AWG and larger: IEEE 383, IEEE
1202/CSA FT4
UL 1685
Other Compliances
EPA 40 CFR, Part 261 for leachable lead content per TCLP
OSHA Acceptable
RoHS Compliant
Packaging
Material cut to length and shipped on non-returnable wood reels
Options
2 kV version
Bare copper conductor
Other stranding available

Size
AWG or
KCMIL

Insulation
Thickness
(mil)

Nominal
Conductor
Diameter
(in)

Minimum
Average
Insulation
Thickness
(in)

Minimum
Average
Insulation
Diameter
(in)

Minimum
Average
Jacket
Thickness
(in)

Minimum
Average
Jacket
Diameter
(in)

Copper
Weight
(lb/MFT)

Net
Weight
(lb/MFT)

14
12
10
8
6
4
2
1/0
2/0

7/.0242
7/.0305
7/.0385
7/.0486
7/.0612
7/.0772
7/.0974
19/.0740
19/.0837

0.07
0.09
0.12
0.15
0.18
0.23
0.29
0.37
0.41

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055

0.14
0.16
0.18
0.24
0.28
0.33
0.39
0.48
0.53

0.015
0.015
0.015
0.015
0.030
0.030
0.030
0.045
0.045

0.17
0.19
0.21
0.28
0.35
0.39
0.46
0.58
0.63

13
20
32
50
81
129
205
326
411

24
33
48
77
122
178
265
422
518

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

241
20150108

LOW VOLTAGE CABLES

Construction
Conductor: 14 AWG thru 1000 kcmil compressed tinned copper per ASTM B33, Class B
stranding per ASTM B8
Insulation: Composite Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO) colored for contrast with black Low-Smoke, ZeroHalogen Cross-linked Polyolefin (LSZH XLPO)
Print: AMERICAN WIRE GROUP LSZH TYPE
USE-2 OR RHH OR RHW-2 (SIZE) 600 V OIL RES
I SUN RES -40C ST1* FOR CT USE* (UL)
DAY/MONTH/YEAR OF MFG SEQUENTIALFOOTAGE MARK* ST1 and FOR CT USE on
1/0 AWG and larger.

Resistant to most oils and chemicals


UV/sunlight-resistant
Rated ST-1 for Limited Smoke per UL 44 on
sizes 1/0 AWG and larger
Stable electrical properties over a broad temperature range
Excellent low temperature cold bend characteristics, meets cold bend and cold impact test
at -40C

LSZH XLPO/LSZH XLPO


Low-Voltage Power, Unshielded 600 V
UL Type RHH/RHW-2/USE-2
Item#

Size
AWG or
KCMIL

Nominal
Conductor
Diameter
(in)

19/.1055
37/.0822
37/.0973
37/.1162
61/.1109
61/.1280

0.52
0.56
0.67
0.80
0.97
1.13

Minimum
Average
Insulation
Thickness
(in)
0.055
0.065
0.065
0.065
0.080
0.080

Minimum
Average
Insulation
Diameter
(in)
0.64
0.70
0.81
0.94
1.15
1.31

Minimum
Average
Jacket
Thickness
(in)
0.045
0.065
0.065
0.065
0.065
0.065

Minimum
Average
Jacket
Diameter
(in)
0.74
0.85
0.96
1.09
1.31
1.46

Copper
Weight
(lb/MFT)

Net
Weight
(lb/MFT)

653
772
1081
1542
2316
3806

785
960
1299
1803
2664
3989

LOW VOLAGE CABLES

4/0-01XLSOH
4/0
250-01XLSOH
250
350-01XLSOH
350
500-01XLSOH
500
750-01XLSOH
750
1000-01XLSOH 1000

Insulation
Thickness
(mil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
241
20150108

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

SunGuard Tracker Motor Cable


UL Type PV/TC 2kV
Applications
As three-conductor power cables rated 2000
volts, 90C in dry or wet locations for Solar PV
generation, this cable is connected to the tracker
motors. Approved for installation in cable trays
per Article 336 of the NEC. Type TC-ER cables are
approved for use in Class 1, Division 2 hazardous locations. Cables may be installed in
open air, in ducts or conduits, or in tray or
trough. All cables when used in accordance with
the NEC meet the requirements of OSHA.

Item #

10-03XHPGTC2000

Notes
Dimensions are approximate and subject to
normal manufacturing tolerances.
SHIPPING TOLERANCE +/- 10%

Size
AWG

No. of
Conductors

Ground
Wire
Size AWG

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Nominal
Conductor
OD
(in)

Approx.
Weight
(lb/MFT)

10

10

60

60

0.64

280

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

239
2015108

LOW VOLTAGE CABLES

Construction
Stranded copper conductors, XLP (Cross-Linked
Polyethylene) insulation, Method 4 phase-identified; three insulated conductors cabled together
with a stranded copper grounding conductor in
one interstice, fillers as necessary, cable tape,
black sunlight-resistant PVC (Polyvinyl Chloride)
jacket overall, surface printed.

Specifications
Copper conductors conform to ASTM B-3 and
B-8.
Insulated conductors RHH/RHW-2 Type per UL
44, USE-2 Type per UL 854, and PV Type per
UL 4703, UL 1277 Type TC-ER
Cable is designed to pass the UL 1581, IEEE383, IEEE-1202 and VW-1 flame tests.
Cable is suitable for sunlight resistant and direct burial applications, and is approved For
CT Use.
Cable meets the requirements of ICEA S-95658/NEMA WC70.

LOW VOLAGE CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

MEDIUM VOLTAGE CABLES


Table of Contents
EPR Non-Shielded 2400V MV-90 ..........................................................................................301
L824 Type C Single Conductor, Non-Shielded XLPE 5000V Airport Lighting....................302
MV-105 Copper EPR Copper Tape Shield 5kV-133%/8kV-100% Insulation Level ...............303
MV-105 Copper EPR Copper Tape Shield 15kV 133% & 100% Insulation Levels...............304
MV-105 Copper EPR Copper Tape Shield 35kV 133% & 100% Insulation Level ................305
URD 175 Mil TRXLP 15kV 100% LLDPE Jacket AEIC CS-8...................................................306
URD 175 Mil EPR 15kV 100% LLDPE Jacket AEIC CS-8.......................................................307
URD 220 Mil TRXLP 15kV 133% LLDPE Jacket AEIC CS-8...................................................308
URD 220 Mil EPR 15kV 133% LLDPE Jacket AEIC CS-8.......................................................309
URD 260 Mil TRXLP 25kV 100% LLDPE Jacket AEIC CS-8 ...................................................310
URD 260 Mil EPR 25kV 100% LLDPE Jacket AEIC CS-8 .......................................................311
URD 345 Mil EPR 35kV 100% LLDPE Jacket AEIC CS-8.......................................................313
PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07...............................................................................312
PowerGuard 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable
LLDPE Jacket UL MV- 90/AEIC CS8-07 - PHYSICAL PROPERTIES ..................................318

PowerGuard 5kV-35kV AluminumTR-XLPE Tape Shield


PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................314
PowerGuard 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground
PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................316
PowerGuard 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground
PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................317
PowerGuard 15kV 133% Shielded Power Cable AL Conductor 220 mils
EPR Copper Tape PVC Jacket MV-105................................................................................319

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

300
20160225

MEDIUM VOLTAGE
CABLES

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


XLPE Jacket UL MV-105/AEIC CS8-07 ...............................................................................315

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Power Cable
EPR Non-Shielded PVC Jacket
2400V MV-90
Application
These cables comply with the exception notes of NEC Article 310.6 with respect to non-shielded cables above 2000V and the requirements of Table 310.63 for wet and dry locations. Consequently,
where NEC requirements apply, this cable is suitable for use in wet and dry locations at a continuous conductor operating temperature of 90C, at an emergency overload conductor temperature of
130C and at a short circuit conductor temperature of 250C. These cables may be installed in duct
or conduit or properly supported aerial installations. Cables that are rated for use in cable tray applications are shown on the individual product specification sheets.
Construction
Conductors:The conductor is made up of uncoated soft, copper strands meeting the requirements
of ASTM B3. Unless otherwise specified the conductors are supplied as Class B compact per ASTM
B496.
Insulation: The insulation is ethylene-propylene rubber (EPR) extruded concentrically over the conductor to the wall thickness as specified in the governing specifications listed and as shown on the
individual product specification sheets.
Jacket: A sunlight and ozone resistant jacket of polyvinylchloride (PVC) or chlorinated polyethylene
(CPE) is extruded over the single and multi conductor assembly. Optional jacket materials are available that offer enhanced ratings and performance.
Standards
1)Listed by UL as Type MV-90 per Standard 1072.
2)Conforms to ICEA S-96-659/N EMA WC71 Non-Shielded 2001 V - 5KV Cables.
3)Listed by UL For CT Use (Sizes #1/0 AWG and larger CPE jacketed).

Item #

Size
AWG
or KCM

2400-EPR-8
2400-EPR-6
2400-EPR-4
2400-EPR-2
2400-EPR-1
2400-EPR-1/0
2400-EPR-2/0
2400-EPR-3/0
2400-EPR-4/0
2400-EPR-250
2400-EPR-350
2400-EPR-500
2400-EPR-750
2400-EPR-1000

8*
6*
4*
2
1*
1/0
2/0
3/0
4/0
250
350
500
750
1000*

Number of
Strands

Conductor
Nominal
O.D.

Insulation
(mil)

Jacket
(mil)

Approximate
O.D.
(in)

Ampacity**
40C
Ambient
(lb)

Approximate
Net Weight
/MFT

0.14
0.18
0.23
0.27
0.32
0.34
0.38
0.42
0.48
0.52
0.62
0.74
0.91
1.12

125
125
125
125
125
125
125
125
125
140
140
140
155
155

80
80
80
80
80
80
80
95
95
110
110
110
125
125

0.62
0.64
0.69
0.75
0.78
0.81
0.86
0.94
0.99
1.11
1.21
1.33
1.58
1.79

55
75
97
130
155
180
205
240
280
315
385
475
600
690

215
260
330
430
500
585
685
815
1010
1190
1590
2120
3090
3950

(in)
7
7
7
7
19
19
19
19
19
37
37
37
61
61

*Compressed conductors.
**Based on three single conductor cables in isolated conduit in air per NEC tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

301
20140917

MEDIUM VOLTAGE
CABLES

Notes
NEC 2005 no longer recognizes non-shielded 5000V construction and only recognizes 2400V nonshielded with the specific constructions attributes included in this specification. These cables meet
the current relevant ICEA standards for 5000V non-shielded cables.

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

L824 Type C Airport Lighting Cables


Single Conductor, Non-Shielded XLPE
5000V
Application
For runway, taxiway and approach in underground series airport lighting circuits. At 5000 V rated
voltage and maximum conductor temperatures of 90C for continuous normal operation and 250C
for short circuit.
Suitable for use in wet or dry conditions in metallic and non-metallic conduits, ducts, aerial and direct earth burial installations.
Construction
A bare copper seven wires stranded circular conductor covered with a separator tape has an extruded tracking resistant XLPE (crosslinked polyethylene) insulation, non-jacketed.
Also available with conductor shield, insulation shield and / or PVC or PE jacket, upon request.
Standard supply lengths are 5000 ft / reel. Other reel lengths are available upon request.
Flexible stranding of 19 strands available.
Standards
Conforms to:
FAA Advisory Circular (AC)150/5345-7E, Specification for L-824 Type C
L824 Type B also available.
NEMA WC71 / ICEA S-96-659-1999 for non-shielded cables.
Certification
ETL Certified.
FAA Listed as an Approved Supplier

Item #

Conductor
Size
AWG

Number
of Strands
in Conductor

Nominal
Diameter
of Conductor
(in)

DC Resistance
of Conductor
@ 25C
/MFT

Separator
Tape
Thickness
(mil)

Nominal
of Insulation
(in)

Nominal
Diameter
(in)

Ampacity
Underground
in Duct

ALC-8
ALC-6
ALC-4

8
6
4

7
7
7

0.143
0.180
0.226

0.652
0.411
0.258

0.5
0.5
0.5

110
110
110

0.364
0.401
0.447

64
85
110

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

302
20140110

MEDIUM VOLTAGE
CABLES

Option
Shielded
LSOH Jacket

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

MV-105 Copper EPR Copper Tape Shield


5kV-133%/8kV-100% Insulation Level
Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105C, at not more than 140C. for emergency overload conditions and
250C during short-circuits. Suitable for systems rated 5kV/8kV, 133% insulation level (grounded
systems).
Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.
Standards
National Electrical Code (NEC)
UL-1072 MV-105
ICEA S-93-639/NEMA WC74
ICEA S-97-682
AEIC CS8
UL listed as Type MV-105 for use in accordance with NEC
Sizes 4/0 AWG and larger are listed and marked Sunlight-Resistant FOR CT USE in accordance
with NEC

Item #

105-115E2
105-115E1
105-115E1/0
105-115E2/0
105-115E3/0
105-115E4/0
105-115E250
105-115E350
105-115E500
105-115E750
105-115E1000

Size
AWG or
KCM

Stranding

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Diameter
Over
Insulation
(in)

Diameter
Over
Insulation
Shield
(in)

Diameter
Overall
(in)

Net
Weight
per
1000 ft.
(lb)

Ampacity
1/C
in Cable
Tray

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Conduit
in Air

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

7
19
19
19
19
19
37
37
37
61
61

115
115
115
115
115
115
115
115
115
115
115

55
55
55
70
70
70
70
70
70
70
70

0.550
0.590
0.640
0.690
0.740
0.800
0.860
0.960
1.080
1.270
1.420

0.640
0.680
0.720
0.770
0.820
0.870
0.930
1.030
1.170
1.360
1.510

0.840
0.880
0.920
0.980
1.030
1.080
1.140
1.240
1.370
1.560
1.710

510
620
670
790
920
1080
1230
1580
2090
2950
3910

122
137
290
335
385
445
495
610
765
990
1185

165
185
215
245
275
315
345
415
500
610
690

165
190
215
255
290
330
365
440
535
655
755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

303
20140921

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).
CPE or CSPE Jacket available.

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

MV-105 220 Mil EPR Copper Tape Shield


15kV 133% & 100% Insulation Levels
Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105C, at not more than 140C. for emergency overload conditions and
250C during short-circuits. Suitable for systems rated 15 kV, 133% & 100% insulation level
(grounded systems).
Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.
Standards
National Electrical Code (NEC)
UL-1072 MV-105
ICEA S-93-639/NEMA WC74
ICEA S-97-682
AEIC CS8
UL listed as Type MV-105 for use in accordance with NEC
Sizes 4/0 AWG and larger are listed and marked Sunlight-Resistant FOR CT USE in accordance
with NEC

Item #

Size
AWG or
KCM

220 Mils EPR 133%


105-220E2
105-220E1/0
105-220E2/0
105-220E3/0
105-220E4/0
105-220E250
105-220E350
105-220E500
105-220E750
105-220E1000

2
1/0
2/0
3/0
4/0
250
350
500
750
1000

Stranding

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Diameter
Over
Insulation
(in)

Diameter
Over
Insulation
Shield
(in)

Diameter
Overall
(in)

Net
Weight
per
1000 ft.
(lb)

Ampacity
1/C
in Cable
Tray

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Conduit
in Air

7
19
19
19
19
37
37
37
61
61

220
220
220
220
220
220
220
220
220
220

70
70
70
70
70
70
70
70
100
100

0.790
0.870
0.910
0.960
1.020
1.080
1.180
1.310
1.500
1.650

0.860
0.920
0.910
1.010
1.080
1.140
1.240
1.370
1.560
1.730

1.080
1.140
1.180
1.230
1.290
1.350
1.470
1.600
1.790
2.020

700
870
930
1070
1250
1420
1800
2360
3360
4290

122
290
335
385
445
495
610
756
990
1185

165
215
245
275
315
345
415
500
610
690

165
215
255
290
330
365
440
535
655
755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

304
20140921

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).
CPE or CSPE Jacket available.

MV-105 220 Mil EPR Copper Tape Shield


15kV 133% & 100% Insulation Levels
Item #

Size
AWG or
KCM

2
1/0
2/0
3/0
4/0
250
350
500
750
1000

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Diameter
Over
Insulation
(in)

Diameter
Over
Insulation
Shield
(in)

Diameter
Overall
(in)

Net
Weight
per
1000 ft.
(lb)

Ampacity
1/C
in Cable
Tray

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Conduit
in Air

7
19
19
19
19
37
37
37
61
61

175
175
175
175
175
175
175
175
175
175

70
70
70
70
70
70
70
70
100
100

0.700
0.780
0.820
0.870
0.930
0.990
1.090
1.220
1.410
1.560

0.770
0.860
0.900
0.950
1.010
1.070
1.190
1.320
1.510
1.680

1.000
1.050
1.090
1.140
1.200
1.260
1.380
1.510
1.700
1.930

620
780
680
1000
1170
1320
1720
2270
3140
4170

122
290
335
385
445
495
610
756
990
1185

165
215
245
275
315
345
415
500
610
690

165
215
255
290
330
365
440
535
655
755

MEDIUM VOLAGE
CABLES

175 Mils EPR 100%


105-175E2
105-175E1/0
105-175E2/0
105-175E3/0
105-175E4/0
105-175E250
105-175E350
105-175E500
105-175E750
105-175E1000

Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
304
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

MV-105 Copper EPR Copper Tape Shield


35kV 133% & 100% Insulation Level
Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105C, at not more than 140C for emergency overload conditions and
250C during short-circuits. Suitable for systems rated 35 kV, 133% & 100% insulation level
(grounded systems).
Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.
Standards
National Electrical Code (NEC)
UL-1072 MV-105
ICEA S-93-639/NEMA WC74
ICEA S-97-682
AEIC CS8
UL listed as Type MV-105 for use in accordance with NEC
Sizes 4/0 AWG and larger are listed and marked Sunlight-Resistant FOR CT USE in accordance
with NEC

Item #

Size
AWG or
KCM

420 Mils EPR 133%


105-420E1/0
105-420E2/0
105-420E3/0
105-420E4/0
105-420E250
105-420E350
105-420E500
105-420E750
105-420E1000

1/0
2/0
3/0
4/0
250
350
500
750
1000

Stranding

Minimum
Point
Insulation
(mil)

Minimum
Point
Jacket
(mil)

Diameter
Over
Insulation
(in)

Diameter
Over
Insulation
Shield
(in)

Diameter
Overall
(in)

Net
Weight
/MFT
(lb)

Ampacity
1/C
in Cable
Tray

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Conduit
in Air

19
19
19
19
37
37
37
61
61

420
420
420
420
420
420
420
420
420

70
70
70
70
100
100
100
100
100

1.250
1.310
1.360
1.410
1.470
1.580
1.700
1.890
2.040

1.340
1.390
1.450
1.500
1.570
1.680
1.820
2.010
2.160

1.550
1.600
1.650
1.710
1.840
1.930
2.070
2.280
2.430

1370
1500
1650
1840
2140
2590
3240
4260
5230

N/A
N/A
N/A
445
495
610
765
990
1185

215
245
275
315
345
415
500
610
690

215
255
290
330
365
440
535
655
755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

305
20140921

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).

MV-105 Copper EPR Copper Tape Shield


35kV 133% & 100% Insulation Level
Item #

Size
AWG or
KCM

1/0
2/0
3/0
4/0
250
350
500
750
1000

Minimum
Point
Insulation
(mil)

Minimum
Point
Jacket
(mil)

Diameter
Over
Insulation
(in)

Diameter
Over
Insulation
Shield
(in)

Diameter
Overall
(in)

Net
Weight
/MFT
(lb)

Ampacity
1/C
in Cable
Tray

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Conduit
in Air

19
19
19
19
37
37
37
61
61

345
345
345
345
345
345
345
345
345

70
70
70
70
70
100
100
100
100

1.110
1.150
1.200
1.260
1.330
1.430
1.550
1.740
1.890

1.200
1.250
1.290
1.340
1.420
1.520
1.660
1.860
2.020

1.390
1.440
1.490
1.550
1.600
1.780
1.910
2.120
2.270

1180
1300
1460
1650
1830
2230
2930
3960
4920

N/A
N/A
N/A
445
495
610
765
990
1185

215
245
275
315
345
415
500
610
690

215
255
290
330
365
440
535
655
755

MEDIUM VOLAGE
CABLES

345 mils EPR 100%


105-345E1/0
105-345E2/0
105-345E3/0
105-345E4/0
105-345E250
105-345E350
105-345E500
105-345E750
105-345E1000

Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
305
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 175 Mil TRXLP 15 kV 100%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in
ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable
insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable
as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Options
EPR insulation
Filled strand
Cable core water blocking

Item #

Code
Name

Cond.
Size
AWG

Full Neutral Aluminum Conductor


175-TRXPL-01
Arch
2
175-TRXPL-02 Cezanne
2
175-TRXPL-03 Soffit
1
175-TRXPL-04 Botticelli
1
175-TRXPL-05 Joists
1/0
175-TRXPL-06 Van Gogh 1/0
175-TRXPL-07 Goya
2/0
175-TRXPL-08 El Greco 3/0
175-TRXPL-09 Corot
4/0
1/3 Neutral Aluminum Conductor
175-TRXLP-10 Gable
1/0
175-TRXLP-11
N/A
1/0
175-TRXLP-12
N/A
2/0
175-TRXLP-13
N/A
3/0
175-TRXLP-14
N/A
4/0
175-TRXLP-15 Degas
250
175-TRXLP-16
Hals
350
175-TRXLP-17 Bosch
500
175-TRXLP-18 Vernet 750
175-TRXLP-19
N/A
1000

Cond.
Stranding

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter Diameter Diameter


Diameter
Over
Over
Over
Over
Insulation Insulation Neutral Embedded
(in)
Shield
Wires
Jacket
(in)
(in)
(in)

Total
Total
Ampacity Ampacity Ampacity.
w/o w/Embedded 1/C
1/C
1/C
Jacket
Jacket
in Cable
Duct
Conduit.
Weight
Weight
Tray
Buried
in Air
(lb)
(lb)

Solid
7
Solid
19
Solid
19
19
19
19

10
10
13
13
16
16
13
16
20

14
14
14
14
14
14
12
12
12

0.258
0.283
0.289
0.322
0.325
0.362
0.405
0.456
0.512

0.670
0.695
0.700
0.730
0.735
0.770
0.815
0.865
0.920

0.750
0.775
0.780
0.810
0.815
0.850
0.895
0.945
1.000

0.878
0.903
0.908
0.938
0.943
0.978
1.057
1.107
1.162

0.978
1.003
1.008
1.038
1.043
1.078
1.157
1.207
1.262

356
370
424
437
494
510
616
730
875

477
487
543
556
615
632
760
874
1030

170
170
195
195
230
230
270
295
335

115
115
140
140
155
155
185
210
240

100
100
123
123
135
135
162
184
210

Solid
19
19
19
19
37
37
37
61
61

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.362
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.735
0.770
0.815
0.865
0.920
0.980
1.080
1.210
1.400
1.545

0.815
0.850
0.895
0.945
1.000
1.060
1.200
1.330
1.520
1.705

0.943
0.978
1.023
1.073
1.128
1.188
1.362
1.492
1.724
1.909

1.043
1.078
1.123
1.173
1.228
1.288
1.462
1.562
1.884
2.069

356
373
434
510
598
684
913
1207
1685
2210

460
515
575
655
759
889
1175
1498
2057
2516

230
230
250
280
320
345
405
460
515
565

165
165
190
215
245
270
325
385
475
540

145
145
167
189
215
237
285
338
417
475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

306
201400924

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

URD 175 Mil TRXLP 15 kV 100%


LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE
CABLES

Item #

Code
Name

Cond.
Size
AWG

Full Neutral Copper Conductor


175-TRXLP-20 Titan
2
175-TRXLP-21 Monet
1
175-TRXLP-22 Raphael 1/0
175-TRXLP-23 Rubens 2/0
175-TRXLP-24 Bruegel 3/0
175-TRXLP-25
N/A
4/0
1/3 Neutral Copper Conductor
175-TRXLP-26
N/A
1/0
175-TRXLP-27
N/A
2/0
175-TRXLP-28
N/A
3/0
175-TRXLP-29 Holbein 4/0
175-TRXLP-30 Moreau 250
175-TRXLP-31 McNeil 350
175-TRXLP-32 Daumier 500
175-TRXLP-33
N/A
750
175-TRXLP-34
N/A
1000

Cond.
Stranding

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter Diameter Diameter


Diameter
Over
Over
Over
Over
Insulation Insulation Neutral Embedded
(in)
Shield
Wires
Jacket
(in)
(in)
(in)

Total
Total
Ampacity Ampacity Ampacity.
w/o w/Embedded 1/C
1/C
1/C
Jacket
Jacket
in Cable
Duct
Conduit.
Weight
Weight
Tray
Buried
in Air
(lb)
(lb)

7
19
19
19
19
19

16
13
16
20
25
32

14
12
12
12
12
12

0.283
0.322
0.362
0.405
0.456
0.512

0.695
0.730
0.770
0.815
0.865
0.920

0.775
0.810
0.850
0.895
0.945
1.000

0.902
0.972
1.012
1.057
1.107
1.162

1.003
1.072
1.112
1.157
1.207
1.262

642
504
923
1107
1334
1642

700
570
993
1176
1402
1708

225
260
295
330
375
430

160
185
210
240
270
305

140
162
185
210
237
268

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.362
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.770
0.815
0.865
0.920
0.980
1.080
1.210
1.400
1.545

0.850
0.899
0.945
1.000
1.060
1.200
1.330
1.520
1.705

0.978
1.023
1.073
1.162
1.222
1.404
1.534
1.724
1.945

1.078
1.123
1.173
1.262
1.322
1.504
1.694
1.884
2.106

708
836
1002
1227
1427
1904
2664
3794
4948

777
907
1074
1317
1546
2055
2823
3964
5127

290
320
350
390
415
475
525
560
600

210
240
275
315
340
415
480
530
590

185
210
241
276
298
364
420
465
518

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
306
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 175 Mil EPR 15 kV 100%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric
neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Notes.
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

Item #

Cond.
Stranding

Full Neutral Aluminum Conductor


175-EPR-01
2
Solid
175-EPR-02
2
7
175-EPR-03
1
Solid
175-EPR-04
1
19
175-EPR-05
1/0
Solid
175-EPR-06
1/0
19
175-EPR-07
2/0
19
175-EPR-08
3/0
19
175-EPR-09
4/0
19
1/3 Neutral Aluminum Conductor
175-EPR-10
1/0
Solid
175-EPR-11
1/0
19
175-EPR-12
2/0
19
175-EPR-13
3/0
19
175-EPR-14
4/0
19
175-EPR-15
250
37
175-EPR-16
350
37
175-EPR-17
500
37
175-EPR-18
750
61
175-EPR-19
1000
61

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

10
10
13
13
16
16
13
16
20

14
14
14
14
14
14
12
12
12

0.258
0.290
0.289
0.330
0.325
0.370
0.420
0.470
0.530

0.670
0.690
0.700
0.730
0.735
0.770
0.820
0.870
0.930

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

0.735
0.770
0.820
0.870
0.930
0.990
1.090
1.220
1.410
1.570

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.750
0.750
0.780
0.800
0.815
0.840
0.880
0.930
0.990

0.878
0.880
0.908
0.930
0.943
0.970
1.010
1.100
1.150

0.978
0.980
1.008
1.030
1.043
1.070
1.110
1.200
1.260

451
455
520
536
594
615
732
848
1009

512
518
581
600
656
680
810
927
1090

170
170
195
195
230
230
270
295
335

115
115
140
140
155
155
185
210
240

100
100
123
123
135
135
162
184
210

0.815
0.840
0.880
0.930
0.990
1.050
1.190
1.330
1.520
1.710

0.943
0.970
0.010
0.100
0.130
0.170
0.360
1.490
1.720
1.920

1.043
1.070
1.110
1.200
1.230
1.270
1.460
1.590
1.890
2.030

471
482
552
630
737
849
1111
1442
1959
2524

539
547
630
709
818
959
1253
1590
2149
2727

230
230
250
280
320
345
405
460
515
565

165
165
190
215
245
270
325
385
475
540

145
145
167
189
215
237
285
338
417
475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

307
20140924

MEDIUM VOLTAGE
CABLES

Cond.
Size
AWG

URD 175 Mil EPR 15 kV 100%


LLDPE Jacket AEIC CS-8
Item #

Cond.
Size
AWG

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

7
19
19
19
19
19

16
13
16
20
25
32

14
12
12
12
12
12

0.290
0.330
0.370
0.420
0.470
0.530

0.690
0.730
0.770
0.820
0.870
0.930

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

0.770
0.820
0.870
0.930
0.990
1.090
1.220
1.410
1.570

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.750
0.800
0.840
0.880
0.930
0.990

0.880
0.930
0.970
1.010
1.100
1.150

0.980
1.030
1.070
1.110
1.200
1.260

677
811
960
1166
1398
1703

740
875
1025
1244
1477
1784

225
260
295
330
375
430

160
210
210
240
270
305

140
185
185
210
237
268

0.840
0.880
0.930
0.990
1.050
1.190
1.330
1.520
1.710

0.970
1.010
1.100
1.150
1.190
1.360
1.490
1.720
1.920

1.070
1.110
1.200
1.250
1.290
1.460
1.590
1.890
2.030

749
891
1056
1267
1487
2022
2712
3873
5028

814
969
1135
1348
1597
2164
2860
4063
5231

290
320
350
390
415
475
525
560
600

210
240
275
315
340
415
480
530
590

185
210
241
276
298
364
420
465
518

MEDIUM VOLAGE
CABLES

Full Neutral Copper Conductor


175-EPR-20
2
175-EPR-21
1
175-EPR-22
1/0
175-EPR-23
2/0
175-EPR-24
3/0
175-EPR-25
4/0
1/3 Neutral Copper Conductor
175-EPR-26
1/0
175-EPR-27
2/0
175-EPR-28
3/0
175-EPR-29
4/0
175-EPR-30
250
175-EPR-31
350
175-EPR-32
500
175-EPR-33
750
175-EPR-34
1000

Cond.
Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
307
2014092

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 220 Mil TRXLP 15kV 133%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable
insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Options
EPR insulation
Filled strand
Cable core water blocking

Item #

Cond.
Size
AWG

Cond.
Stranding

Full Neutral Aluminum Conductor


220-TRXLP-01
2
Solid
220-TRXLP-02
2
7
220-TRXLP-03
1
Solid
220-TRXLP-04
1
19
220-TRXLP-05
1/0
Solid
220-TRXLP-06
1/0
19
220-TRXLP-07
2/0
19
220-TRXLP-08
3/0
19
220-TRXLP-09
4/0
19
1/3 Neutral Aluminum Conductor
220-TRXLP-10
1/0
Solid
220-TRXLP-11
1/0
19
220-TRXLP-12
2/0
19
220-TRXLP-13
3/0
19
220-TRXLP-14
4/0
19
220-TRXLP-15
250
37
220-TRXLP-16
350
37
220-TRXLP-17
500
37
220-TRXLP-18
750
61
220-TRXLP-19
1000
61

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

10
10
13
13
16
16
13
16
20

14
14
14
14
14
14
12
12
12

0.258
0.283
0.289
0.322
0.325
0.362
0.405
0.456
0.512

0.760
0.785
0.790
0.820
0.825
0.860
0.905
0.955
1.010

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.362
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.825
0.860
0.905
0.955
1.010
1.070
1.170
1.300
1.490
1.635

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.840
0.865
0.870
0.900
0.905
0.940
0.985
1.035
1.090

0.968
0.993
0.998
1.028
1.033
1.068
1.147
1.197
1.252

1.068
1.093
1.098
1.128
1.133
1.168
1.247
1.297
1.352

401
415
470
487
544
562
670
787
934

537
549
604
619
680
697
830
946
1148

170
170
195
195
230
230
270
295
335

115
115
140
140
155
155
185
210
240

100
100
123
123
135
135
162
184
210

0.905
0.940
0.985
1.035
1.090
1.190
1.290
1.420
1.610
1.795

1.033
1.068
1.113
1.163
1.218
1.318
1.452
1.582
1.814
1.999

1.133
1.168
1.213
1.263
1.318
1.418
1.612
1.742
1.974
2.159

423
441
490
567
656
781
987
1284
1774
2301

562
580
643
725
842
1013
1266
1597
2230
2718

230
230
250
280
320
345
405
460
515
565

165
165
190
215
245
270
325
385
475
540

145
145
167
189
215
237
285
338
417
475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

308
201401924

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

URD 220 Mil TRXLP 15kV 133%


LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE
CABLES

Item #

Cond.
Size
AWG

Full Neutral Copper Conductor


220-TRXLP-20
2
220-TRXLP-21
1
220-TRXLP-22
1/0
220-TRXLP-23
2/0
220-TRXLP-24
3/0
220-TRXLP-25
4/0
1/3 Neutral Copper Conductor
220-TRXLP-26
1/0
220-TRXLP-27
2/0
220-TRXLP-28
3/0
220-TRXLP-29
4/0
220-TRXLP-30
250
220-TRXLP-31
350
220-TRXLP-32
500
220-TRXLP-33
750
220-TRXLP-34
1000

Cond.
Stranding

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

7
19
19
19
19
19

16
13
16
20
25
32

14
12
12
12
12
12

0.283
0.322
0.362
0.405
0.456
0.512

0.785
0.820
0.860
0.905
0.955
1.010

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.362
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.860
0.905
0.955
1.010
1.070
1.170
1.300
1.490
1.635

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.865
0.900
0.940
0.985
1.035
1.090

0.993
1.062
1.102
1.147
1.197
1.294

1.093
1.162
1.202
1.247
1.293
1.394

695
559
982
1169
1399
1747

760
633
1060
1246
1475
1825

225
260
295
330
375
430

160
185
210
240
270
305

140
162
185
210
237
268

0.940
0.985
1.035
1.090
1.190
1.290
1.420
1.610
1.795

1.068
1.113
1.163
1.294
1.352
1.494
1.624
1.814
1.999

1.168
1.213
1.263
1.394
1.452
1.654
1.784
1.974
2.159

767
897
1066
1333
1539
1987
2754
3952
5061

842
975
1145
1434
1673
2149
2924
4138
5251

290
320
350
390
415
475
525
560
600

210
240
275
315
340
415
480
530
590

185
210
241
276
298
364
420
465
518

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
308
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 220 Mil EPR 15kV 133%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral;
LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Notes
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

Item #

Cond.
Stranding

Full Neutral Aluminum Conductor


220-EPR-01
2
Solid
220-EPR-02
2
7
220-EPR-03
1
Solid
220-EPR-04
1
19
220-EPR-05
1/0
Solid
220-EPR-06
1/0
19
220-EPR-07
2/0
19
220-EPR-08
3/0
19
220-EPR-09
4/0
19
1/3 Neutral Aluminum Conductor
220-EPR-10
1/0
Solid
220-EPR-11
1/0
19
220-EPR-12
2/0
19
220-EPR-13
3/0
19
220-EPR-14
4/0
19
220-EPR-15
250
37
220-EPR-16
350
37
220-EPR-17
500
37
220-EPR-18
750
61
220-EPR-19
1000
61

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

10
10
13
13
16
16
13
16
20

14
14
14
14
14
14
12
12
12

0.258
0.290
0.289
0.330
0.325
0.370
0.420
0.470
0.530

0.760
0.780
0.790
0.830
0.825
0.870
0.910
0.960
1.020

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

0.825
0.870
0.910
0.960
1.020
1.080
1.180
1.310
1.510
1.660

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.840
0.840
0.870
0.890
0.905
0.930
0.980
1.030
1.120

0.968
0.970
0.998
1.020
1.033
1.060
1.100
1.190
1.290

1.068
1.075
1.098
1.121
1.133
1.161
1.207
1.291
1.389

518
534
587
606
665
691
808
926
1135

585
603
655
676
733
764
895
1015
1228

170
170
195
195
230
230
270
295
335

115
115
140
140
155
155
185
210
240

100
100
123
123
135
135
162
184
210

0.905
0.930
0.980
1.030
1.120
1.180
1.290
1.420
1.610
1.810

1.033
1.060
1.100
1.190
1.270
1.370
1.450
1.580
1.810
2.010

1.133
1.161
1.207
1.291
1.369
1.469
1.552
1.746
1.980
2.175

541
558
628
708
863
978
1219
1555
2144
2667

616
631
715
797
956
1092
1369
1715
2349
2882

230
230
250
280
320
345
405
460
515
565

165
165
190
215
245
270
325
385
475
540

145
145
167
189
215
237
285
338
417
475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

309
20140924

MEDIUM VOLTAGE
CABLES

Cond.
Size
AWG

URD 220 Mil EPR 15kV 133%


LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE
CABLES

Item #

Cond.
Size
AWG

Cond.
Stranding

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

Full Neutral Copper Conductor


220-EPR-20
2
220-EPR-21
1
220-EPR-22
1/0
220-EPR-23
2/0
220-EPR-24
3/0
220-EPR-25
4/0

7
19
19
19
19
19

16
13
16
20
25
32

14
12
12
12
12
12

0.290
0.330
0.370
0.420
0.470
0.530

0.780
0.830
0.870
0.910
0.960
1.020

1/3 Neutral Copper Conductor


220-EPR-26
1/0
220-EPR-27
2/0
220-EPR-28
3/0
220-EPR-29
4/0
220-EPR-30
250
220-EPR-31
350
220-EPR-32
500
220-EPR-33
750
220-EPR-34
1000

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

0.870
0.910
0.960
1.020
1.080
1.180
1.310
1.510
1.660

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.840
0.890
0.930
0.980
1.030
1.120

0.970
1.040
1.080
1.100
1.190
1.290

1.075
1.141
1.181
1.207
1.291
1.389

756
881
1036
1242
1476
1829

825
951
1109
1329
1565
1922

225
260
295
330
375
430

160
185
210
240
270
305

140
162
185
210
237
268

0.930
0.980
1.030
1.120
1.180
1.290
1.420
1.610
1.810

1.080
1.100
1.190
1.310
1.410
1.490
1.620
1.810
2.010

1.181
1.207
1.291
1.410
1.509
1.592
1.786
1.980
2.175

825
967
1134
1393
1616
2130
2825
4058
5171

898
1054
1223
1486
1730
2280
2985
4263
5386

290
320
350
390
415
475
525
560
600

210
240
275
315
340
415
480
530
590

185
210
241
276
298
364
420
465
518

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
309
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 260 Mil TRXLP 25kV 100%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in
ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable
insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable
as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Options
EPR insulation
Filled strand
Cable core water blocking

Item #

Code
Name

Cond.
Size
AWG

Full Neutral Aluminum Conductor


260-TRXLP-01
N/A
1
260-TRXLP-02 Liszt
1
260-TRXLP-03
N/A
1/0
260-TRXLP-04 Verdi
1/0
260-TRXLP-05
Ives
2/0
260-TRXLP-06 Bach
3/0
260-TRXLP-07 Mozart
4/0
1/3 Neutral Aluminum Conductor
260-TRXLP-08
N/A
1/0
260-TRXLP-09
N/A
1/0
260-TRXLP-10
N/A
2/0
260-TRXLP-11
N/A
3/0
260-TRXLP-12
N/A
4/0
260-TRXLP-13 Wagner 250
260-TRXLP-14 Gould
350
260-TRXLP-15 Schubert 500
260-TRXLP-16 Strauss 750
260-TRXLP-17
N/A
1000

Cond.
Stranding

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter Diameter Diameter


Diameter
Over
Over
Over
Over
Insulation Insulation Neutral Embedded
(in)
Shield
Wires
Jacket
(in)
(in)
(in)

Total
Total
Ampacity Ampacity Ampacity.
w/o w/Embedded 1/C
1/C
1/C
Jacket
Jacket
in Cable
Duct
Conduit.
Weight
Weight
Tray
Buried
in Air
(lb)
(lb)

Solid
19
Solid
19
19
19
19

13
13
16
16
13
16
20

14
14
14
14
12
12
12

0.289
0.322
0.325
0.362
0.405
0.456
0.512

0.870
0.900
0.905
0.940
0.985
1.035
1.090

0.950
0.980
0.989
1.022
1.065
1.155
1.210

1.078
1.108
1.117
1.150
1.227
1.317
1.372

1.178
1.208
1.217
1.250
1.327
1.417
1.472

518
535
590
614
722
875
1025

671
687
748
767
905
1065
1241

195
195
220
220
250
290
325

145
145
165
165
190
210
245

127
127
145
145
167
185
215

Solid
19
19
19
19
37
37
37
61
61

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.362
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.905
0.940
0.985
1.035
1.090
1.160
1.260
1.390
1.580
1.725

0.989
1.022
1.065
1.155
1.210
1.280
1.380
1.510
1.740
1.885

1.117
1.150
1.193
1.283
1.338
1.408
1.542
1.672
1.944
2.089

1.217
1.250
1.293
1.383
1.438
1.508
1.702
1.832
2.104
2.249

460
475
540
655
750
852
1060
1369
1920
2405

631
650
715
842
966
1117
1380
1721
2373
2870

225
225
250
275
310
335
395
445
515
560

165
165
180
205
240
260
325
390
475
525

145
145
158
180
210
228
285
342
417
460

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

310
20140924

MEDIUM VOLTAGE
CABLES

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section
392.13; operating at 105C conductor, at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating at 105C conductor, 20C ground ambient, earth =
90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC
Table 310.73).
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

URD 260 Mil TRXLP 25kV 100%


LLDPE Jacket AEIC CS-8
Item #

Code
Name

Cond.
Size
AWG

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter Diameter Diameter


Diameter
Over
Over
Over
Over
Insulation Insulation Neutral Embedded
(in)
Shield
Wires
Jacket
(in)
(in)
(in)

Total
Total
Ampacity Ampacity Ampacity.
w/o w/Embedded 1/C
1/C
1/C
Jacket
Jacket
in Cable
Duct
Conduit.
Weight
Weight
Tray
Buried
in Air
(lb)
(lb)

19
19
19
19
19

13
16
20
25
32

12
12
12
12
12

0.322
0.362
0.405
0.456
0.512

0.900
0.940
0.985
1.035
1.090

0.980
1.022
1.065
1.155
1.210

1.142
1.184
1.227
1.317
1.372

1.242
1.284
1.327
1.417
1.472

615
1044
1232
1502
1828

701
1133
1321
1594
1919

245
280
315
360
415

185
215
240
275
315

162
189
210
241
276

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.352
0.405
0.456
0.512
0.558
0.660
0.789
0.968
1.117

0.940
0.985
1.035
1.090
1.160
1.260
1.390
1.580
1.725

1.022
1.065
1.155
1.210
1.280
1.380
1.510
1.741
1.885

1.150
1.193
1.283
1.371
1.442
1.584
1.714
1.944
2.089

1.250
1.293
1.383
1.471
1.602
1.744
1.874
2.104
2.249

826
960
1166
1414
1628
2083
2858
4071
5190

912
1048
1261
1528
1780
2266
3050
4280
5404

275
310
345
385
410
460
520
567
625

215
250
285
320
345
405
470
450
615

189
220
250
280
303
355
412
483
540

MEDIUM VOLAGE
CABLES

Full Neutral Copper Conductor


260-TRXLP-18 Handel
1
260-TRXLP-19 Haydn
1/0
260-TRXLP-20 Brahms 2/0
260-TRXLP-21 Ravel
3/0
260-TRXLP-22 Chopin 4/0
1/3 Neutral Copper Conductor
260-TRXLP-23
N/A
1/0
260-TRXLP-24
N/A
2/0
260-TRXLP-25
N/A
3/0
260-TRXLP-26
N/A
4/0
260-TRXLP-27 Dufay
250
260-TRXLP-28 Schuetz 350
260-TRXLP-29 Lully
500
260-TRXLP-30
N/A
750
260-TRXLP-31
N/A
1000

Cond.
Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
310
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 260 Mil EPR 25kV 100%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral;
LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Notes
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

Item #

Cond.
Stranding

Full Neutral Aluminum Conductor


260-EPR-01
1
Solid
260-EPR-02
1
19
260-EPR-03
1/0
Solid
260-EPR-04
1/0
19
260-EPR-05
2/0
19
260-EPR-06
3/0
19
260-EPR-07
4/0
19
1/3 Neutral Aluminum Conductor
260-EPR-08
1/0
Solid
260-EPR-09
1/0
19
260-EPR-10
2/0
19
260-EPR-11
3/0
19
260-EPR-12
4/0
19
260-EPR-13
250
37
260-EPR-14
350
37
260-EPR-15
500
37
260-EPR-16
750
61
260-EPR-17
1000
61

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

13
13
16
16
13
16
20

14
14
14
14
12
12
12

0.289
0.330
0.325
0.370
0.420
0.470
0.530

0.870
0.910
0.905
0.950
0.990
1.040
1.100

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

0.905
0.950
0.990
1.040
1.100
1.160
1.260
1.400
1.590
1.740

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.950
0.970
0.989
1.010
1.060
1.150
1.210

1.078
1.100
1.117
1.140
1.190
1.310
1.370

1.178
1.200
1.217
1.240
1.290
1.410
1.470

657
676
736
762
886
1038
1233

735
757
815
845
986
1141
1340

195
195
220
220
250
290
325

145
145
165
165
190
210
245

127
127
145
145
167
185
215

0.989
1.010
1.060
1.150
1.210
1.260
1.400
1.500
1.730
1.890

1.117
1.140
1.190
1.310
1.370
1.470
1.530
1.660
1.940
2.090

1.217
1.240
1.290
1.410
1.470
1.570
1.700
1.830
2.100
2.260

612
629
706
820
961
1086
1328
1681
2294
2827

698
712
806
923
1068
1229
1500
1865
2528
3072

225
225
250
275
310
335
395
445
515
560

165
165
180
205
240
260
325
390
475
525

145
145
158
180
210
228
285
342
417
460

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

311
20140924

MEDIUM VOLTAGE
CABLES

Cond.
Size
AWG

URD 260 Mil EPR 25kV 100%


LLDPE Jacket AEIC CS-8
Item #

Cond.
Size
AWG

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

19
19
19
19
19

13
16
20
25
32

12
12
12
12
12

0.330
0.370
0.420
0.470
0.530

0.910
0.950
0.990
1.040
1.100

19
19
19
19
37
37
37

9
11
14
11
13
12
17

14
14
14
12
12
10
10

0.370
0.420
0.470
0.530
0.570
0.680
0.810

0.950
0.990
1.040
1.100
1.160
1.260
1.400

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

0.970
1.010
1.060
1.150
1.210

1.100
1.160
1.190
1.310
1.370

1.200
1.260
1.290
1.410
1.470

951
1107
1320
1588
1927

1032
1190
1420
1691
2034

245
280
315
360
415

185
215
240
275
315

162
189
210
241
276

1.010
1.060
1.150
1.210
1.260
1.400
1.500

1.140
1.190
1.310
1.390
1.490
1.570
1.700

1.240
1.290
1.410
1.490
1.590
1.740
1.870

896
1045
1246
1491
1724
2239
2951

996
1148
1353
1634
1896
2423
3185

275
310
345
385
410
460
520

215
250
285
320
345
405
470

189
220
250
280
303
355
412

MEDIUM VOLAGE
CABLES

Full Neutral Copper Conductor


260-EPR-18
1
260-EPR-19
1/0
260-EPR-20
2/0
260-EPR-21
3/0
260-EPR-22
4/0
1/3 Neutral Copper Conductor
260-EPR-23
1/0
260-EPR-24
2/0
260-EPR-25
3/0
260-EPR-26
4/0
260-EPR-27
250
260-EPR-28
350
260-EPR-29
500

Cond.
Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
311
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

URD 345 Mil EPR 35kV 100%


LLDPE Jacket AEIC CS-8
Applications
For use on single phase and three phase primary underground distribution systems operating at
35kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric
neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Notes
Maximum conductor temperature: 90C normal continuous, 130C overload, 250C short circuit.

Item #

Cond.
Stranding

Full Neutral Aluminum Conductor


345-EPR-01
1/0
Solid
345-EPR-02
1/0
19
345-EPR-03
2/0
19
345-EPR-04
3/0
19
345-EPR-05
4/0
19
1/3 Neutral Aluminum Conductor
345-EPR-06
1/0
Solid
345-EPR-07
1/0
19
345-EPR-08
2/0
19
345-EPR-09
3/0
19
345-EPR-10
4/0
19
345-EPR-11
250
37
345-EPR-12
350
37
345-EPR-13
500
37
345-EPR-14
750
61
345-EPR-15
1000
61

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

16
16
13
16
20

14
14
12
12
12

0.325
0.370
0.420
0.470
0.530

1.075
1.120
1.170
1.220
1.280

6
6
7
9
11
13
11
16
15
20

14
14
14
14
14
14
12
12
10
10

0.325
0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

1.075
1.120
1.170
1.220
1.280
1.330
1.440
1.570
1.760
1.920

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

1.195
1.230
1.270
1.320
1.380

1.323
1.350
1.400
1.480
1.540

1.423
1.460
1.500
1.590
1.710

938
968
1105
1236
1433

1034
1068
1224
1356
1558

220
220
250
285
325

165
165
195
220
250

145
145
310
193
220

1.195
1.230
1.270
1.320
1.380
1.440
1.540
1.720
1.930
2.060

1.323
1.350
1.400
1.480
1.540
1.640
1.700
1.880
2.110
2.270

1.423
1.460
1.500
1.590
1.710
1.810
1.890
2.040
2.280
2.430

736
835
925
1018
1161
1301
1558
2003
2590
3143

815
935
1044
1138
1286
1484
1752
2213
2850
3415

215
215
245
275
305
335
390
440
515
570

165
165
190
215
245
270
320
385
475
535

145
145
167
189
215
238
280
338
417
470

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

313
201400924

MEDIUM VOLTAGE
CABLES

Cond.
Size
AWG

URD 345 Mil EPR 35kV 100%


LLDPE Jacket AEIC CS-8
Item #

Cond.
Size
AWG

Copper
Neutral
No.of
Wires

Copper
Neutral
Size
AWG

Conductor Diameter Diameter


Diameter
Over
Over
Insulation Insulation
(in)
Shield
(in)

19
19
19
19

16
20
25
32

12
12
12
12

0.370
0.420
0.470
0.530

1.120
1.170
1.220
1.280

19
19
19
19
37
37
37
61
61

9
11
14
11
13
12
17
25
33

14
14
14
12
12
10
10
10
10

0.370
0.420
0.470
0.530
0.570
0.680
0.810
0.990
1.140

1.120
1.170
1.220
1.280
1.330
1.440
1.570
1.760
1.920

Diameter Diameter
Over
Over
Neutral Embedded
Wires
Jacket
(in)
(in)

Total
Total
Ampacity
w/o w/Embedded 1/C
Jacket
Jacket
in Cable
Weight
Weight
Tray
(lb)
(lb)

Ampacity Ampacity.
1/C
1/C
Duct
Conduit.
Buried
in Air

1.230
1.270
1.320
1.380

1.350
1.400
1.480
1.540

1.460
1.500
1.590
1.710

1313
1539
1786
2127

1413
1658
1906
2252

280
310
355
410

215
240
275
315

189
211
241
276

1.230
1.270
1.320
1.380
1.440
1.540
1.720
1.930
2.060

1.350
1.400
1.480
1.540
1.640
1.700
1.880
2.110
2.270

1.460
1.500
1.590
1.710
1.810
1.890
2.040
2.280
2.430

1102
1264
1444
1691
1939
2469
3273
4504
5647

1221
1384
1569
1874
2133
2679
3533
4776
5647

270
305
340
380
405
460
520
567
625

215
240
280
315
340
400
470
550
615

189
211
246
276
298
350
412
483
540

MEDIUM VOLAGE
CABLES

Full Neutral Copper Conductor


345-EPR-16
1/0
345-EPR-17
2/0
345-EPR-18
3/0
345-EPR-19
4/0
1/3 Neutral Copper Conductor
345-EPR-20
1/0
345-EPR-21
2/0
345-EPR-22
3/0
345-EPR-23
4/0
345-EPR-24
250
345-EPR-25
350
345-EPR-26
500
345-EPR-27
750
345-EPR-28
1000

Cond.
Stranding

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
313
20140924

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Applications
PowerGuard cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.
Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuardTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric
neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE)
jacket.

Insulation Temperature Rating


Normal.............................. 90C
Emergency*.................... 130C
Short Circuit.................... 250C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.
Specifications
ASTM B-231
AEIC CS8
ICEA S-94-649
ICEA T-31-610
ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
UL 1072 MV-90
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
Options
Copper Conductors
Black LLDPE jacket with no stripes
Multiplex cables
Factory Warranty
20 Years

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

312
20160110

MEDIUM VOLTAGE
CABLES

Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation.
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649 - 100% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires
to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1
hour.
Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral
wires with three extruded red stripes and NESC lightning bolt symbol.

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE
CABLES

Item #

CONDUCTOR
AL Size Nominal
AWG or Diameter1
kcmil
(in)

PHYSICAL PROPERTIES
UR1C1ALW-1614DA35 1/0
UR1C1ALW-1114DA35 1/0
UR1C1ALW-0814DA35 1/0
UR1C1ALW-0614DA35 1/0
UR1C2ALW-2014DA35 2/0
UR1C2ALW-1414DA35 2/0
UR1C2ALW-1014DA35 2/0
UR1C2ALW-0714DA35 2/0
UR1C3ALW-1612DA35 3/0
UR1C3ALW-1714DA35 3/0
UR1C3ALW-1314DA35 3/0
UR1C3ALW-0914DA35 3/0
UR1C4ALW-2012DA35 4/0
UR1C4ALW-2114DA35 4/0
UR1C4ALW-1614DA35 4/0
UR1C4ALW-1114DA35 4/0
UR1C4ALW-0614DA35 4/0
UR1E5ALX-1314DA35 250
UR1E5ALX-1016DA35 250
UR1E5ALX-0616DA35 250
UR1F5ALX-1609DA35
350
UR1F5ALX-2212DA35
350
UR1F5ALX-1712DA35
350
UR1F5ALX-1814DA35
350
UR1F5ALX-0914DA35
350
UR1F5ALX-0716DA35
350
UR1H0ALX-2010DA35 500
UR1H0ALX-2412DA35 500
UR1H0ALX-1612DA35 500
UR1H0ALX-1314DA35 500
UR1H0ALX-1016DA35 500
UR1J5ALY-2310DA35
750
UR1J5ALY-2412DA35
750
UR1J5ALY-1914DA35
750
UR1J5ALY-1014DA35
750
UR1K0ALY-3010DA35 1000
UR1K0ALY-2010DA35 1000
UR1K0ALY-1612DA35 1000
UR1K0ALY-1314DA35 1000
UR1M5ALZ-2510DA35 1250
UR1M5ALZ-2012DA35 1250
UR1M5ALZ-1614DA35 1250
UR1P0ALZ-2409DA35 1500
UR1P0ALZ-2412DA35 1500
UR1P0ALZ-1914DA35 1500

0.362
0.362
0.362
0.362
0.408
0.408
0.408
0.408
0.458
0.458
0.458
0.458
0.515
0.515
0.515
0.515
0.515
0.561
0.561
0.561
0.661
0.661
0.661
0.661
0.661
0.661
0.790
0.790
0.790
0.790
0.790
0.968
0.968
0.968
0.968
1.117
1.117
1.117
1.117
1.250
1.250
1.250
1.370
1.370
1.370

INSULATION2
Minimum Maximum
Diameter Diameter
(in)
(in)

1.045
1.045
1.045
1.045
1.090
1.090
1.090
1.090
1.140
1.140
1.140
1.140
1.195
1.195
1.195
1.195
1.195
1.250
1.250
1.250
1.355
1.355
1.355
1.355
1.355
1.355
1.480
1.480
1.480
1.480
1.480
1.670
1.670
1.670
1.670
1.815
1.815
1.815
1.815
1.960
1.960
1.960
2.100
2.100
2.100

1.145
1.145
1.145
1.145
1.190
1.190
1.190
1.190
1.240
1.240
1.240
1.240
1.295
1.295
1.295
1.295
1.295
1.350
1.350
1.350
1.455
1.455
1.455
1.455
1.455
1.455
1.580
1.580
1.580
1.580
1.580
1.770
1.770
1.770
1.770
1.920
1.920
1.920
1.920
2.065
2.065
2.065
2.205
2.205
2.205

CONCENTRIC NEUTRAL
Size
No. of
Size of
Wires
Wires

Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
1/6
1/3
1/6
1/12
Full
2/3
1/2
1/3
1/6
1/12
2/3
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/3
1/6
1/12
1/3
1/6
1/12

16
11
8
6
20
14
10
7
16
17
13
9
20
21
16
11
6
13
10
6
16
22
17
18
9
7
20
24
16
13
10
23
24
19
10
30
20
16
13
25
20
16
24
24
19

14
14
14
14
14
14
14
14
12
14
14
14
12
14
14
14
14
14
16
16
9
12
12
14
14
16
10
12
12
14
16
10
12
14
14
10
10
12
14
10
12
14
9
12
14

JACKET4
Nominal
Diameter
(in)
(lb)

Aluminum
Weight
/MFT
(lb)

WEIGHTS
Copper
Weight
/MFT
(lb)

Net
Weight4
/MFT

1.41
1.41
1.41
1.41
1.45
1.45
1.45
1.45
1.56
1.50
1.50
1.50
1.60
1.58
1.58
1.58
1.58
1.62
1.60
1.60
1.90
1.81
1.81
1.77
1.77
1.74
1.98
1.95
1.95
1.92
1.89
2.20
2.16
2.14
2.14
2.36
2.36
2.32
2.27
2.61
2.54
2.49
2.69
2.62
2.58

99
99
99
99
125
125
125
125
157
157
157
157
198
198
198
198
198
234
234
234
328
328
328
328
328
328
469
469
469
469
469
703
703
703
703
937
937
937
937
1173
1173
1173
1408
1408
1408

209
144
104
78
266
187
133
93
332
222
170
118
415
274
209
144
78
170
84
51
667
458
354
235
117
59
662
498
332
170
84
761
498
248
133
993
660
332
173
827
415
209
1002
497
248

914
841
812
802
982
912
865
852
1190
1044
951
944
1330
1171
1126
1074
1020
1160
1069
1033
1993
1695
1603
1457
1358
1256
2181
1983
1854
1669
1629
2727
2434
2163
2076
3311
3015
2658
2455
3755
3225
2984
4036
3474
3193

1) Diameters are based on ASTM Class B Compressed diameters.


2) Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of
AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
3) Ampacity based on earth thermal resistivity of 90C-cm/watt, 90C conductor temperature, 20C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one
conductor per phase, with neutral wires bonded at each end.
4) Cables buried in flat adjacent configuration with 7.5" spacing between conductors.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
312
20160110

Information on this sheet subject to change without notice


Copyright 2016, American Wire Group, Inc.

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item #

Pos./Neg. Seq1
Impedence
(/ft)
239 + J53
238 + J53
238 + J53
238 + J53
185 + J50
185 + J50
184 + J51
184 + J51
147 + J49
146 + J49
146 + J49
145 + J49
116 + J47
115 + J47
114 + J47
114 + J47
113 + J47
96 + J46
96 + J45
95 + J45
74 + J44
72 + J44
71 + J44
70 + J44
69 + J44
68 + J44
53 + J41
51 + J42
50 + J42
49 + J42
48 + J42
39 + J38
37 + J39
35 + J40
34 + J40
32 + J35
30 + J37
27 + J38
26 + J38
26 + J36
23 + J37
21 + J37
24 + J34
21 + J35
19 + J36

TREFOIL
Zero Seq1
Impedence
(/ft)
414 +
475 +
528 +
568 +
331 +
384 +
440 +
497 +
264 +
315 +
357 +
419 +
209 +
253 +
291 +
351 +
442 +
308 +
423 +
446 +
131 +
157 +
184 +
235 +
346 +
417 +
109 +
129 +
166 +
258 +
370 +
87 +
115 +
188 +
288 +
66 +
87 +
145 +
236 +
70 +
118 +
199 +
60 +
100 +
174 +

J81
J126
J187
J263
J64
J94
J143
J223
J51
J74
J102
J162
J42
J58
J77
J123
J261
J100
J251
J412
J31
J37
J45
J68
J165
J367
J29
J33
J45
J96
J245
J25
J31
J58
J136
J22
J25
J42
J94
J22
J33
J71
J20
J28
J57

Ampacity1
Trefoil
(amps)
217
217
217
217
250
250
251
251
286
286
286
287
328
328
329
329
330
362
362
362
429
431
433
434
436
437
522
525
530
533
536
328
637
648
656
718
735
757
772
798
837
863
855
899
934

FLAT SPACED @ 7.5


FLAT SPACED TOUCHING
Pos./Neg Seq2
Zero Seq2
Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3.
Impedence
Impedence
Flat
Impedence Impedence
Flat
(/ft)
(/ft)
(amps)
(/ft)
(/ft)
(amps)
255
250
246
244
204
199
195
191
168
162
159
154
139
133
129
125
119
109
102
99
95
93
90
85
77
72
74
72
68
59
53
58
56
48
42
48
48
42
35
43
39
31
39
37
29

+ J90
+ J93
+ J95
+ J95
+ J85
+ J89
+ J91
+ J92
+ J79
+ J85
+ J87
+ J89
+ J72
+ J79
+ J83
+ J86
+ J88
+ J83
+ J86
+ J86
+ J57
+ J66
+ J71
+ J77
+ J81
+ J82
+ J54
+ J61
+ J69
+ J75
+ J78
+ J48
+ J58
+ J68
+ J72
+ J40
+ J49
+ J63
+ J68
+ J43
+ J57
+ J65
+ J38
+ J53
+ J62

407
462
506
536
326
375
425
470
261
309
348
401
207
250
285
339
412
299
394
402
130
157
182
230
329
378
108
127
164
251
345
86
114
185
276
65
86
143
230
69
116
195
58
99
171

+ J84
+ J130
+ J191
+ J262
+ J67
+ J98
+ J148
+ J225
+ J53
+ J78
+ J106
+ J167
+ J43
+ J60
+ J81
+ J128
+ J261
+ J105
+ J251
+ J394
+ J32
+ J38
+ J47
+ J71
+ J170
+ J355
+ J29
+ J34
+ J47
+ J101
+ J247
+ J26
+ J32
+ J61
+ J142
+ J22
+ J26
+ J44
+ J99
+ J22
+ J34
+ J74
+ J20
+ J29
+ J60

232
233
234
235
266
268
269
271
300
303
305
307
339
343
346
350
354
381
388
391
423
427
433
445
460
468
495
497
513
544
565
568
576
620
666
635
633
678
746
671
708
793
714
734
826

240 +
239 +
238 +
237 +
187 +
185 +
185 +
184 +
149 +
147 +
147 +
146 +
119 +
117 +
116 +
114 +
113 +
97 +
96 +
99 +
77 +
75 +
74 +
72 +
70 +
69 +
56 +
54 +
52 +
50 +
48 +
42 +
40 +
37 +
35 +
35 +
33 +
30 +
27 +
30 +
30 +
23 +
27 +
24 +
21 +

J57
J58
J58
J58
J55
J55
J55
J55
J54
J53
J54
J54
J51
J52
J52
J52
J53
J51
J51
J86
J46
J48
J49
J49
J49
J49
J43
J45
J46
J47
J47
J40
J43
J44
J45
J46
J40
J42
J43
J37
J42
J42
J34
J39
J40

412 +
472 +
525 +
563 +
330 +
382 +
487 +
493 +
263 +
314 +
355 +
413 +
208 +
252 +
289 +
349 +
438 +
306 +
418 +
402 +
131 +
159 +
183 +
234 +
343 +
412 +
109 +
128 +
166 +
257 +
366 +
87 +
115 +
188 +
286 +
66 +
86 +
144 +
235 +
69 +
144 +
199 +
59 +
100 +
174 +

J81
J126
J187
J262
J64
J94
J143
J222
J52
J74
J102
J162
J42
J58
J77
J123
J260
J100
J250
J394
J31
J37
J45
J68
J165
J364
J29
J33
J45
J96
J245
J25
J31
J59
J137
J22
J25
J42
J95
J22
J42
J71
J20
J28
J57

216
217
217
217
250
250
250
251
285
285
286
286
326
327
327
328
329
361
361
391
421
427
429
431
435
436
505
511
522
530
534
592
610
638
651
659
682
727
761
720
727
836
759
821
892

1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90C cm/W, earth ambient of 20C, neutral wires grounded at both ends,
75% load factor, conductor temperature of 90C, and 36 depth of burial.
2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5 center-to-center spacing, earth rho of 90C-cm/W, earth ambient of 20C, neutral wires
grounded at both ends, 75% load factor, conductor temperature of 90C, and 36 depth of burial.
3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90C-cm/ W, earth ambient of 20C, neutral wires grounded at both
ends, 75% load factor, conductor temperature of 90C, and 36 depth of burial.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

312
20160110

MEDIUM VOLTAGE
CABLES

CONDUCTOR NEUTRAL
AL Size Size
AWG or
kcmil
ELECTRICAL PROPERTIES
UR1C1ALW-1614DA35
1/0
FULL
UR1C1ALW-1114DA35
1/0
2/3
UR1C1ALW-0814DA35
1/0
1/2
UR1C1ALW-0614DA35
1/0
1/3
UR1C2ALW-2014DA35
2/0
Full
UR1C2ALW-1414DA35
2/0
2/3
UR1C2ALW-1014DA35
2/0
1/2
UR1C2ALW-0714DA35
2/0
1/3
UR1C3ALW-1612DA35
3/0
Full
UR1C3ALW-1714DA35
3/0
2/3
UR1C3ALW-1314DA35
3/0
1/2
UR1C3ALW-0914DA35
3/0
1/3
UR1C4ALW-2012DA35
4/0
Full
UR1C4ALW-2014DA35
4/0
2/3
UR1C4ALW-1614DA35
4/0
1/2
UR1C4ALW-1114DA35
4/0
1/3
UR1C4ALW-0614DA35
4/0
1/6
UR1C5ALX-1314DA35
250
1/3
UR1C5ALX-1016DA35
250
1/6
UR1C5ALX-0616DA35
250
1/12
UR1C5ALX-1609DA35
350
Full
UR1C5ALX-2212DA35
350
2/3
UR1C5ALX-1712DA35
350
1/2
UR1C5ALX-1814DA35
350
1/3
UR1C5ALX-0914DA35
350
1/6
UR1C5ALX-0716DA35
350
1/12
UR1H0ALX-2010DA35
500
2/3
UR1H0ALX-2412DA35
500
1/2
UR1H0ALX-1612DA35
500
1/3
UR1H0ALX-1314DA35
500
1/6
UR1H0ALX-1016DA35
500
1/12
UR1J0ALY-2310DA35
750
1/2
UR1J0ALY-2412DA35
750
1/3
UR1J0ALY-1914DA35
750
1/6
UR1J0ALY-1014DA35
750
1/12
UR1K0ALY-3010DA35
1000
1/2
UR1K0ALY-2010DA35
1000
1/3
UR1K0ALY-1612DA35
1000
1/6
UR1K0ALY-1314DA35
1000 1/12
UR1M0ALZ-2510DA35 1250
1/3
UR1M0ALZ-2012DA35 1250
1/6
UR1M0ALZ-1614DA35 1250 1/12
UR1P0ALZ-2409DA35
1500
1/3
UR1P0ALZ-2412DA35
1500
1/6
UR1P0ALZ-1914DA35
1500 1/12

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE
CABLES

Item #

CONDUCTOR NEUTRAL
AL Size
Size
AWG or
or No.
kcmil
of Wires
CONCENTRIC NEUTRAL CURRENT WITHSTAND
UR1C1ALW-1614DA35
1/0
16X14
UR1C1ALW-1114DA35
1/0
11X14
UR1C1ALW-0814DA35
1/0
8X14
UR1C1ALW-0614DA35
1/0
6X14
UR1C2ALW-2014DA35
2/0
20X14
UR1C2ALW-1414DA35
2/0
14X14
UR1C2ALW-1014DA35
2/0
10X14
UR1C2ALW-0714DA35
2/0
7X14
UR1C3ALW-1612DA35
3/0
16X12
UR1C3ALW-1714DA35
3/0
17X14
UR1C3ALW-1314DA35
3/0
13X14
UR1C3ALW-0914DA35
3/0
9X14
UR1C4ALW-2012DA35
4/0
20X12
UR1C4ALW-2114DA35
4/0
21X14
UR1C4ALW-1614DA35
4/0
16X14
UR1C4ALW-1114DA35
4/0
11X14
UR1C4ALW-0614DA35
4/0
6X14
UR1E5ALX-1314DA35
250
13X14
UR1E5ALX-1016DA35
250
10x16
UR1E5ALX-0616DA35
250
6X16
UR1F5ALX-1609DA35
350
16X9
UR1F5ALX-2212DA35
350
22X12
UR1F5ALX-1712DA35
350
17X12
UR1F5ALX-1814DA35
350
18X14
UR1F5ALX-0914DA35
350
9X14
UR1F5ALX-0716DA35
350
7X16
UR1H0ALX-2010DA35
500
20X10
UR1H0ALX-2412DA35
500
24X12
UR1H0ALX-1612DA35
500
16X12
UR1H0ALX-1314DA35
500
13x14
UR1H0ALX-1016DA35
500
10x16
UR1J5ALY-2310DA35
750
23X10
UR1J5ALY-2412DA35
750
24X12
UR1J5ALY-1914DA35
750
19X14
UR1J5ALY-1014DA35
750
10X14
UR1K0ALY-3010DA35
1000
30X10
UR1K0ALY-2010DA35
1000
20X10
UR1K0ALY-1612DA35
1000
16X12
UR1K0ALY-1314DA35
1000
13X14
UR1M5ALZ-2510DA35
1250
25X10
UR1M5ALZ-2012DA35
1250
20X12
UR1M5ALZ-1614DA35
1250
16X14
UR1P0ALZ-2409DA35
1500
24X9
UR1P0ALZ-2412DA35
1500
24X12
UR1P0ALZ-1914DA35
1500
19X14

Neutral Conductor Capacitance


Size
Resistance (F/Mft)
20C /Mft
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
1/6
1/3
1/6
1/12
Full
2/3
1/2
1/3
1/6
1/12
2/3
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/3
1/6
1/12
1/3
1/6
1/12

0.185
0.185
0.185
0.185
0.143
0.143
0.143
0.143
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.074
0.074
0.074
0.053
0.053
0.053
0.053
0.053
0.053
0.036
0.036
0.036
0.036
0.036
0.025
0.025
0.025
0.025
0.018
0.018
0.018
0.018
0.014
0.014
0.014
0.012
0.012
1.012

0.043
0.043
0.043
0.043
0.046
0.046
0.046
0.046
0.049
0.049
0.049
0.049
0.053
0.053
0.053
0.053
0.053
0.056
0.056
0.056
0.062
0.062
0.062
0.062
0.062
0.062
0.071
0.071
0.071
0.071
0.071
0.082
0.082
0.082
0.082
0.091
0.091
0.091
0.091
0.099
0.099
0.099
0.107
0.107
0.107

10 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

11570
7954
5785
4339
14462
10123
7231
5062
18300
12293
9400
6508
22875
15185
11570
7954
4339
9400
5179
2717
36369
25162
19444
13016
6508
3625
41754
27450
18300
10750
5179
41990
27450
13739
8269
62632
36513
18300
10750
45641
22875
13230
54554
27450
15711

11868
8159
5934
4451
14835
10385
7418
5192
18676
12610
9643
6676
23345
15577
11868
8159
4451
9643
5327
280
36900
25679
19843
13352
6676
3729
42349
28013
18676
10992
5327
42673
28013
14093
8456
63523
37107
18676
10992
46384
23345
13529
55350
28013
16066

20 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

8304
5709
4152
3114
10380
7266
5190
3633
13135
8823
6747
4671
16418
10899
8304
5709
3114
6747
3251
1950
26104
18060
13955
9342
4671
2275
26207
19702
13135
6747
3251
30138
19702
9861
5190
39310
26207
13135
6747
32759
16418
8304
39156
19702
9861

8602
5914
4301
3226
10752
7527
5376
3763
13510
9139
6989
4839
16887
11290
8602
5914
3226
6989
3398
2039
26634
18576
14354
9677
4839
2378
26800
2026
13510
6989
3398
30820
20265
10215
5376
40200
26800
13510
6989
33500
16887
8602
39950
20265
10215

30 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

6432
4422
3216
2412
8040
5628
4020
2814
10174
6834
5226
3618
12717
8442
6432
4422
2412
5226
2518
1511
20220
13989
10810
7236
3618
1763
20300
15261
10174
5226
2518
23345
15261
7638
4020
30450
20300
10174
5226
25375
12717
6432
30330
15261
7638

6730
4627
3365
2524
8412
5888
4206
2944
10549
7150
5468
3785
13186
8833
6730
4627
2524
5468
2665
1599
20749
14504
11208
7571
3785
1865
20892
15823
10549
5468
2665
24026
15823
7991
4206
31339
20892
10549
5468
26115
13186
6730
31124
15823
7991

1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90Ccm/W, earth ambient of 20C, neutral wires grounded at both ends,
75% load factor, conductor temperature of 90C, and 36 depth of burial.
2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5 center-to-center spacing, earth rho of 90Ccm/W, earth ambient of 20C, neutral wires
grounded at both ends, 75% load factor, conductor temperature of 90C, and 36 depth of burial.
3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90Ccm/ W, earth ambient of 20C, neutral wires grounded at both
ends, 75% load factor, conductor temperature of 90C, and 36 depth of burial..

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
312
20160110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable


LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07
PHYSICAL PROPERTIES
Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene
(LLDPE) jacket.
Design Parameters
Conductor: Class B compact stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors
are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation.
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene 420 Mil (TRXLPE) as defined in
ANSI/ICEA S-94-649 - 133% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the
insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires
to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for
1 hour.
Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral
wires with three extruded red stripes and NESC lightning bolt symbol.

Specifications
ASTM B-231
AEIC CS8
ICEA S-94-649
ICEA T-31-610
ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
UL 1072 MV-90
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
Applications
PowerGuard cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.
Options
Copper Conductors
Black LLDPE jacket with no stripes
Multiplex cables
Notes
1. Diameters are based on ASTM Class B Compressed diameters. Sizes 1250 kcmil and 1500 kcmil
are based on ASTM Class A Compressed diameters.
2.Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with
ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements
of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
3.Cables buried in flat adjacent configuration with 7.5"" spacing between conductors.
4.Ampacity based on earth thermal resistivity of 90 C-cm/watt, 90 C conductor temperature, 20 C
earth ambient temperature, 75% load factor and 36"" depth of burial. Values are based on one
three-phase circuit, one conductor per phase, with neutral wires bonded at each end.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

318
20160225

MEDIUM VOLTAGE
CABLES

Insulation Temperature Rating


Normal.............................. 90 C
Emergency*......................130 C
(*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable. )
Short Circuit..................... 250 C

PowerGuard 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable


LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07
PHYSICAL PROPERTIES

MEDIUM VOLAGE
CABLES

Item #

A1/0-01UD35UT100
A1/0-01UD35UT203
A1/0-01UD35UT102
A1/0-01UD35UT103
A2/0-01UD35UT100
A2/0-01UD35UT203
A2/0-01UD35UT102
A2/0-01UD35UT103
A3/0-01UD35UT100
A3/0-01UD35UT203
A3/0-01UD35UT102
A3/0-01UD35UT103
A4/0-01UD35UT100
A4/0-01UD35UT203
A4/0-01UD35UT102
A4/0-01UD35UT103
A4/0-01UD35UT103
A250-01UD35UT103
A250-01UD35UT106
A250-01UD35UT112
A350-01UD35UT100
A350-01UD35UT203
A350-01UD35UT102
A350-01UD35UT103
A350-01UD35UT106
A350-01UD35UT112
A500-01UD35UT203
A500-01UD35UT102
A500-01UD35UT103
A500-01UD35UT106

Conductor
Size
AWG or
kcmil
(1)
1/0
1/0
1/0
1/0
2/0
2/0
2/0
2/0
3/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
4/0
250
250
250
350
350
350
350
350
350
500
500
500
500

Neutral
Size

Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
1/6
1/3
1/6
1/12
Full
2/3
1/2
1/3
1/6
1/12
2/3
1/2
1/3
1/6

No. ofc
Wires

Size of
Wires

Nominal
Diameter
(in)
(2)

16
11
8
6
20
14
10
7
16
17
13
9
20
21
16
11
6
13
10
6
16
22
17
18
9
7
20
24
16
13

14
14
14
14
14
14
14
14
12
14
14
14
12
14
14
14
14
14
16
16
9
12
12
14
14
16
10
12
12
14

0.362
0.362
0.362
0.362
0.408
0.408
0.408
0.408
0.458
0.458
0.458
0.458
0.515
0.515
0.515
0.515
0.515
0.561
0.561
0.561
0.661
0.661
0.661
0.661
0.661
0.661
0.79
0.79
0.79
0.79

Minimal Maximum Nominal


Insulation Insulation Jacket
Diameter Diameter Diameter
(in)
(in)
(in)
(2)
(2)
(2)
1.20
1.30
1.56
1.20
1.30
1.56
1.20
1.30
1.56
1.20
1.30
1.56
1.24
1.34
1.60
1.24
1.34
1.60
1.24
1.34
1.60
1.24
1.34
1.60
1.29
1.53
1.71
1.29
1.53
1.65
1.29
1.53
1.65
1.29
1.53
1.65
1.35
1.45
1.75
1.35
1.45
1.73
1.35
1.45
1.73
1.35
1.45
1.73
1.35
1.45
1.73
1.39
1.49
1.77
1.39
1.49
1.75
1.39
1.49
1.75
1.50
1.60
2.05
1.50
1.60
1.96
1.50
1.60
1.96
1.50
1.60
1.92
1.50
1.60
1.92
1.50
1.60
1.89
1.63
1.73
2.13
1.63
1.73
2.10
1.63
1.73
2.10
1.63
1.73
2.07

Aluminum Copper
Conductor Neutral
(lb/MFT) (lb/MFT)

99
99
99
99
125
125
125
125
157
157
157
157
198
198
198
198
198
234
234
234
328
328
328
328
328
328
469
469
469
469

209
144
104
78
266
187
133
93
332
222
170
118
415
274
209
144
78
170
84
51
667
458
354
235
117
59
662
498
332
170

Total
Weight
(lb/MFT)

1,115
1,026
991
979
1,198
1,113
1,055
1,040
1,452
1,274
1,160
1,152
1,622
1,429
1,374
1,310
1,244
1,415
1,304
1,260
2,431
2,068
1,955
1,777
1,657
1,532
2,660
2,419
2,261
2,036

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
318
20160225

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Application
PowerGuard-XL cables are intended for use in wet or dry locations for distribution of single or
three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Construction
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard-XLTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene jacket.
Conductor is a Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound. Conductor Shield is extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded
to the insulation. Insulation is extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 100% insulation level. Insulation Shield is extruded thermosetting
semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield is solid bare copper wires helically
applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around
the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be
tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement
is 15 psig for 1 hour. The outer jacket is an extruded-to-fill black non-conducting cross-linked polyethylene jacket, meeting the physical requirements of Table 1 when tested by the methods specified
in ANSI/ICEA S-94-649. The jacket shall be free-stripping and not interfere with an intimate contact
between the neutral wires and the underlying extruded insulation shield. The jacket shall contain a
print legend marking, sequential length marking and three longitudinal extruded red stripes. Factory Warranty is 20 Years.
MEDIUM VOLTAGE
CABLES

Options
Copper Conductors
Physical Properties of Extruded-to-Fill XLPE Jacket
Unaged Tensile Strength, min. (PSI) . . .1500
Aged* Tensile Strength, min. ret. (%) . . . .70
Unaged Elongated, min. (%) . . . . . . . . .1500
Aged* Elongated, min. ret. (%) . . . . . . . . .70
Heat Distortion 1 hr at 131 C, max. (%) . . .3
*Aged for 168 hrs at 121 C
Insulation Temperature Rating
Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . .105C
Emergency* . . . . . . . . . . . . . . . . . . . . . . .140C
Short Circuit . . . . . . . . . . . . . . . . . . . . . . .350C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.
Standards
ASTM B-231
AEIC CS8
ICEA S-94-649
ICEA T-31-610
ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
UL 1072 MV-105
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

315
20160216

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE
CABLES

Item #

PHYSICAL PROPERTIES
A1/0-01UD35GT101X
A1/0-01UD35GT203X
A1/0-01UD35GT102X
A1/0-01UD35GT103X
A2/0-01UD35GT101X
A2/0-01UD35GT203X
A2/0-01UD35GT102X
A2/0-01UD35GT103X
A3/0-01UD35GT101X
A3/0-01UD35GT203X
A3/0-01UD35GT102X
A3/0-01UD35GT103X
A4/0-01UD35GT101X
A4/0-01UD35GT203X
A4/0-01UD35GT102X
A4/0-01UD35GT103X
A250-01UD35GT203X
A250-01UD35GT102X
A250-01UD35GT103X
A250-01UD35GT106X
A350-01UD35GT203X
A350-01UD35GT102X
A350-01UD35GT103X
A350-01UD35GT106X
A500-01UD35GT203X
A500-01UD35GT102X
A500-01UD35GT103X
A500-01UD35GT106X
A750-01UD35GT102X
A750-01UD35GT103X
A750-01UD35GT106X
A750-01UD35GT112X
A1000-01UD35GT102X
A1000-01UD35GT103X
A1000-01UD35GT106X
A1000-01UD35GT112X
A1250-01UD35GT103X
A1250-01UD35GT106X
A1250-01UD35GT112X
A1500-01UD35GT103X
A1500-01UD35GT106X
A1500-01UD35GT112X

CONDUCTOR
AL Size Nominal
AWG Diameter1
or kcmil
(in)

1/0
1/0
1/0
1/0
2/0
2/0
2/0
2/0
3/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
250
250
250
250
350
350
350
350
500
500
500
500
750
750
750
750
1000
1000
1000
1000
1250
1250
1250
1500
1500
1500

0.362
0.362
0.362
0.362
0.406
0.406
0.406
0.406
0.456
0.456
0.456
0.456
0.512
0.512
0.512
0.512
0.558
0.558
0.558
0.558
0.661
0.661
0.661
0.661
0.789
0.789
0.789
0.789
0.968
0.968
0.968
0.968
1.117
1.117
1.117
1.117
1.250
1.250
1.250
1.370
1.370
1.370

INSULATION1
Minimum Maximum
Diameter Diameter
(in)
(in)

1.045
1.045
1.045
1.045
1.090
1.090
1.090
1.090
1.140
1.140
1.140
1.140
1.195
1.195
1.195
1.195
1.250
1.250
1.250
1.250
1.355
1.355
1.355
1.355
1.480
1.480
1.480
1.480
1.670
1.670
1.670
1.670
1.815
1.815
1.815
1.815
1.960
1.960
1.960
2.100
2.100
2.100

1.145
1.145
1.145
1.145
1.190
1.190
1.190
1.190
1.240
1.240
1.240
1.240
1.295
1.295
1.295
1.295
1.350
1.350
1.350
1.350
1.455
1.455
1.455
1.455
1.580
1.580
1.580
1.580
1.770
1.770
1.770
1.770
1.920
1.920
1.920
1.920
2.065
2.065
2.065
2.205
2.205
2.205

CONCENTRIC NEUTRAL
Size
No. Size
of
of
Wires Wires

Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
2/3
1/2
1/3
1/6
2/3
1/2
1/3
1/6
2/3
1/2
1/3
1/6
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/3
1/6
1/12
1/3
1/6
1/12

12
13
10
7
15
16
12
9
19
13
15
11
23
15
12
8
19
14
10
8
16
20
13
11
23
18
12
10
17
18
14
15
22
23
12
10
18
15
12
22
18
14

14
16
16
16
14
16
16
16
14
14
16
16
14
14
14
14
14
14
14
16
12
14
14
16
12
12
12
14
10
12
14
16
10
12
12
14
10
12
14
10
12
14

JACKET
Nominal
Diameter
(in)

1.409
1.382
1.382
1.382
1.453
1.427
1.427
1.427
1.503
1.503
1.477
1.477
1.559
1.559
1.559
1.559
1.663
1.663
1.663
1.637
1.803
1.770
1.770
1.743
1.927
1.927
1.927
1.894
2.188
2.146
2.112
2.086
2.339
2.297
2.297
2.263
2.484
2.442
2.408
2.654
2.612
2.578

WEIGHTS
Aluminum Copper Net
Weight Weight Weight
/MFT
/MFT
/MFT
(lb)
(lb)
(lb)
99
99
99
99
125
125
125
125
157
157
157
157
199
199
199
199
235
235
235
235
329
329
329
329
469
469
469
469
704
704
704
704
939
939
939
939
1173
1173
1173
1408
1408
1408

153
104
80
56
192
129
96
72
243
166
120
88
294
192
153
102
243
179
128
64
325
256
166
88
467
366
244
128
549
366
179
120
711
467
244
128
582
305
153
711
366
179

946
869
850
831
1038
948
923
904
1151
1090
1013
987
1278
1196
1166
1125
1404
1353
1312
1216
1718
1602
1530
1420
2083
2001
1904
1746
2709
2468
2246
2142
3226
2931
2752
2581
3513
3185
2952
4081
3691
3454

AMPACITY
DIRECT BURIED
Flat2 Tre-Foil3

216
217
217
217
250
250
250
251
285
285
286
286
326
327
327
328
360
361
361
362
427
429
431
435
505
511
522
530
592
610
638
651
659
682
727
761
720
727
836
759
821
892

217
217
217
217
250
250
251
251
266
286
286
287
328
328
329
329
362
362
363
363
431
433
434
436
522
525
530
533
628
637
648
656
718
735
757
772
798
837
863
855
899
934

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90C-cm/ W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 C-cm/W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
4) UL Type MV-105 PowerGuard-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 C normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105C conductor temperature for normal operation and 140C for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
315
20160216

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item #

TREFOIL
Zero Seq1
Impedence
(/ft)
477 +
543 +
580 +
605 +
386 +
455 +
501 +
535 +
311 +
369 +
425 +
472 +
252 +
311 +
347 +
414 +
260 +
307 +
362 +
448 +
196 +
225 +
291 +
390 +
137 +
160 +
209 +
310 +
110 +
146 +
240 +
306 +
84 +
114 +
186 +
286 +
92 +
152 +
251 +
78 +
131 +
226 +

117J
189J
258J
371J
90J
147J
211J
294J
68J
106J
159J
234J
55J
86J
114J
192J
66J
95J
147J
329J
48J
61J
104J
233J
34J
41J
63J
143J
30J
40J
90J
154J
25J
31J
61J
142J
26J
46J
111J
23J
38J
91J

Ampacity1
Trefoil
(amps)
233
234
234
234
269
269
270
270
307
308
308
308
352
353
353
354
354
389
389
389
463
465
466
469
561
564
569
573
674
685
698
705
770
790
815
831
857
901
930
918
969
1008

FLAT SPACED @ 7.5


FLAT SPACED TOUCHING
Pos./Neg Seq2
Zero Seq2
Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3.
Impedence
Impedence
Flat
Impedence Impedence
Flat
(/ft)
(/ft)
(amps)
(/ft)
(/ft)
(amps)
261
257
255
252
208
203
200
197
170
165
161
158
139
133
130
126
118
113
110
104
92
89
84
78
74
71
66
59
58
54
46
42
50
47
39
33
42
36
29
40
34
27

+ 93J
+ 95J
+ 95J
+ 96J
+ 89J
+ 91J
+ 92J
+ 93J
+ 84J
+ 87J
+ 89J
+ 90J
+ 78J
+ 84J
+ 85J
+ 87J
+ 80J
+ 82J
+ 84J
+ 86J
+ 73J
+ 76J
+ 80J
+ 82J
+ 62J
+ 67J
+ 73J
+ 77J
+ 56J
+ 64J
+ 71J
+ 73J
+ 48J
+ 57J
+ 66J
+ 69J
+ 52J
+ 62J
+ 66J
+ 46J
+ 58J
+ 64J

463
519
547
560
377
437
475
499
305
358
406
443
248
303
336
392
255
297
346
410
193
221
281
364
136
159
205
296
109
145
234
292
84
113
183
274
92
151
243
77
130
220

+ 121J
+ 192J
+ 257J
+ 358J
+ 93J
+ 151J
+ 213J
+ 289J
+ 71J
+ 110J
+ 163J
+ 234J
+ 57J
+ 90J
+ 118J
+ 195J
+ 69J
+ 99J
+ 151J
+ 321J
+ 51J
+ 64J
+ 108J
+ 234J
+ 35J
+ 43J
+ 66J
+ 147J
+ 30J
+ 41J
+ 95J
+ 159J
+ 25J
+ 32J
+ 64J
+ 147J
+ 27J
+ 48J
+ 116J
+ 24J
+ 39J
+ 95J

250
251
252
253
286
288
290
292
323
327
329
331
366
369
373
377
382
411
418
421
466
472
481
496
546
550
564
589
633
642
685
722
711
712
759
823
759
801
886
809
836
931

249 +
249 +
248 +
248 +
194 +
193 +
192 +
192 +
154 +
153 +
152 +
145 +
122 +
120 +
120 +
119 +
103 +
102 +
101 +
100 +
76 +
75 +
74 +
72 +
56 +
55 +
53 +
51 +
42 +
40 +
37 +
36 +
35 +
32 +
29 +
27 +
29 +
25 +
23 +
27 +
23 +
20 +

57J
58J
58J
58J
56J
55J
55J
56J
54J
54J
54J
54J
52J
52J
52J
52J
50J
51J
51J
51J
49J
49J
49J
50J
45J
46J
47J
47J
42J
44J
45J
45J
39J
42J
43J
43J
40J
42J
42J
38J
40J
40J

473 +
538 +
574 +
598 +
384 +
451 +
497 +
530 +
309 +
366 +
421 +
456 +
250 +
309 +
345 +
410 +
259 +
304 +
359 +
442 +
194 +
224 +
289 +
386 +
137 +
159 +
239 +
307 +
110 +
145 +
239 +
303 +
84 +
114 +
185 +
283 +
92 +
153 +
249 +
78 +
131 +
224 +

117J
189J
257J
369J
90J
147J
210J
292J
68J
106J
159J
224J
55J
86J
114J
192J
66J
95J
146J
327J
49J
61J
104J
232J
34J
41J
90J
142J
30J
40J
90J
154J
25J
31J
61J
142J
27J
46J
111J
23J
38J
91J

233
234
234
234
269
269
270
270
307
307
308
308
351
352
353
354
355
388
389
390
459
462
464
468
552
556
563
571
659
671
689
702
748
766
797
821
823
797
912
876
931
982

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90C-cm/ W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 C-cm/W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
4) UL Type MV-105 PowerGuard-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 C normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105C conductor temperature for normal operation and 140C for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

315
20160216

MEDIUM VOLTAGE
CABLES

CONDUCTOR NEUTRAL
AL Size Size Pos./Neg. Seq1
AWG or
Impedence
kcmil
(/ft)
ELECTRICAL PROPERTIES
A1/0-01UD35GT101X
1/0 Full
250 + 53J
A1/0-01UD35GT203X
1/0
2/3
249 + 53J
A1/0-01UD35GT102X
1/0
1/2
249 + 53J
A1/0-01UD35GT103X
1/0
1/3
249 + 53J
A2/0-01UD35GT101X
2/0 Full
193 + 50J
A2/0-01UD35GT203X
2/0
2/3
193 + 50J
A2/0-01UD35GT102X
2/0
1/2
193 + 50J
A2/0-01UD35GT103X
2/0
1/3
192 + 50J
A3/0-01UD35GT101X
3/0 Full
153 + 49J
A3/0-01UD35GT203X
3/0
2/3
152 + 49J
A3/0-01UD35GT102X
3/0
1/2
152 + 49J
A3/0-01UD35GT103X
3/0
1/3
152 + 49J
A4/0-01UD35GT101X
4/0 Full
120 + 47J
A4/0-01UD35GT203X
4/0
2/3
119 + 47J
A4/0-01UD35GT102X
4/0
1/2
119 + 47J
A4/0-01UD35GT103X
4/0
1/3
119 + 47J
A250-01UD35GT203X
250
2/3
102 + 46J
A250-01UD35GT102X
250
1/2
101 + 46J
A250-01UD35GT103X
250
1/3
101 + 46J
A250-01UD35GT106X
250
1/6
100 + 45J
A350-01UD35GT203X
350
2/3
74 + 44J
A350-01UD35GT102X
350
1/2
73 + 44J
A350-01UD35GT103X
350
1/3
73 + 44J
A350-01UD35GT106X
350
1/6
72 + 44J
A500-01UD35GT203X
500 2/3
53 + 41J
A500-01UD35GT102X
500 1/2
53 + 42J
A500-01UD35GT103X
500 1/3
51 + 42J
A500-01UD35GT106X
500 1/6
50 + 42J
A750-01UD35GT102X
750
1/2
39 + 39J
A750-01UD35GT103X
750
1/3
37 + 40J
A750-01UD35GT106X
750
1/6
36 + 40J
A750-01UD35GT112X
750 1/12
35 + 40J
A1000-01UD35GT102X 1000 1/2
31 + 37J
A1000-01UD35GT103X 1000 1/3
29 + 37J
A1000-01UD35GT106X 1000 1/6
27 + 38J
A1000-01UD35GT112X 1000 1/12
26 + 38J
A1250-01UD35GT103X 1250 1/3
25 + 37J
A1250-01UD35GT106X 1250 1/6
23 + 37J
A1250-01UD35GT112X 1250 1/12
22 + 37J
A1500-01UD35GT103X 1500 1/3
23 + 35J
A1500-01UD35GT106X 1500 1/6
20 + 36J
A1500-01UD35GT112X 1500 1/12
19 + 36J

PowerGuard 35kV 100% MV TR-XLPE Aluminum Collection System Cable


XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE
CABLES

Item #

CURRENT WITHSTAND
A1/0-01UD35GT101X
A1/0-01UD35GT203X
A1/0-01UD35GT102X
A1/0-01UD35GT103X
A2/0-01UD35GT101X
A2/0-01UD35GT203X
A2/0-01UD35GT102X
A2/0-01UD35GT103X
A3/0-01UD35GT101X
A3/0-01UD35GT203X
A3/0-01UD35GT102X
A3/0-01UD35GT103X
A4/0-01UD35GT101X
A4/0-01UD35GT203X
A4/0-01UD35GT102X
A4/0-01UD35GT103X
A250-01UD35GT203X
A250-01UD35GT102X
A250-01UD35GT103X
A250-01UD35GT106X
A350-01UD35GT203X
A350-01UD35GT102X
A350-01UD35GT103X
A350-01UD35GT106X
A500-01UD35GT203X
A500-01UD35GT102X
A500-01UD35GT103X
A500-01UD35GT106X
A750-01UD35GT102X
A750-01UD35GT103X
A750-01UD35GT106X
A750-01UD35GT112X
A1000-01UD35GT102X
A1000-01UD35GT103X
A1000-01UD35GT106X
A1000-01UD35GT112X
A1250-01UD35GT103X
A1250-01UD35GT106X
A1250-01UD35GT112X
A1500-01UD35GT103X
A1500-01UD35GT106X
A1500-01UD35GT112X

Conductor
AL Size
AWG or
kcmil

Neutral
Size

Conductor
Resistance
20C /Mft

Capacitance
(F/Mft)

1/0
1/0
1/0
1/0
2/0
2/0
2/0
2/0
3/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
250
250
250
250
350
350
350
350
500
500
500
500
750
750
750
750
1000
1000
1000
1000
1250
1250
1250
1500
1500
1500

Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
Full
2/3
1/2
1/3
2/3
1/2
1/3
1/6
2/3
1/2
1/3
1/6
2/3
1/2
1/3
1/6
1/2
1/3
1/6
1/12
1/2
1/3
1/6
1/12
1/3
1/6
1/12
1/3
1/6
1/12

0.1850
0.1850
0.1850
0.1850
0.1430
0.1430
0.1430
0.1430
0.1130
0.1130
0.1130
0.1130
0.0880
0.0880
0.0880
0.0880
0.0740
0.0740
0.0740
0.0740
0.0530
0.0530
0.0530
0.0530
0.0360
0.0360
0.0360
0.0360
0.0250
0.0250
0.0250
0.0250
0.0180
0.0180
0.0180
0.0180
0.0140
0.0140
0.0140
0.0120
0.0120
0.0120

0.0430
0.0430
0.0430
0.0430
0.0465
0.0465
0.0465
0.0465
0.0494
0.0494
0.0494
0.0494
0.0531
0.0531
0.0531
0.0531
0.0560
0.0560
0.0560
0.0560
0.0624
0.0624
0.0624
0.0624
0.0706
0.0706
0.0706
0.0706
0.0818
0.0818
0.0818
0.0818
0.0912
0.0912
0.0912
0.0912
0.0995
0.0995
0.0995
0.1069
0.1069
0.1069

10 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

8173
5540
4261
2983
10217
6818
5114
3835
12892
8855
6392
4688
15606
10217
8173
5617
13289
9499
6811
3413
17237
13571
9127
4688
24798
19392
12928
6811
29234
19392
9536
6392
37833
24798
12928
6811
31907
16160
8173
38883
19392
9829

8384
5720
4400
3080
10480
7040
5280
3960
13225
9083
6600
4840
16010
10480
8384
5757
13622
9745
6987
3524
17591
13921
9356
4840
25307
19790
13194
6987
29710
19790
9782
6600
38448
25307
13194
6987
32410
16492
8384
39497
19790
10075

20 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

5866
3976
3059
2141
7333
4894
3670
2753
9253
6355
4588
3364
11201
7333
5866
3911
9253
6818
4889
2450
12372
9740
6355
3364
17799
13919
9279
4889
20983
13919
6844
4588
27154
17799
9279
4889
22217
11599
5866
27074
13919
6844

6077
4156
3197
2238
7596
5115
3837
2877
9586
6583
4796
3517
11604
7596
6077
4051
9586
7063
5064
2560
12725
10090
6583
3517
18307
14316
9544
5064
21458
14316
7090
4796
27769
18307
9544
5064
22720
11930
6077
27688
14316
7090

30 CYCLES (AMPS)
Adiabatic
Non
Adiabatic

4544
3080
2369
1658
5680
3791
2843
2132
7167
4923
3554
2606
8676
5680
4544
3029
7167
5281
3787
1897
9583
7545
4923
2606
13787
10781
7188
3787
16253
10781
5301
3554
21033
13787
7188
3787
17209
8984
4544
20972
10781
5301

4754
3260
2507
1755
5943
4012
3009
2257
7499
5150
3761
2758
9078
5943
4754
3169
7499
5526
3962
2008
9936
7894
5150
2758
14294
11178
7452
3962
16728
11178
5547
3761
21647
14294
7452
3962
17712
9315
4754
21585
11178
5547

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90C-cm/ W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 C-cm/W, earth ambient of 20C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105C, and 36" depth of burial.
4) UL Type MV-105 PowerGuard-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 C normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105C conductor temperature for normal operation and 140C for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
315
2010216

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 5kV-35kV Aluminum TR-XLPE Tape Shield


PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Applications
PowerGuard cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.
Construction
Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield
are extruded over an aluminum conductor and cured in a single operation. Uncoated copper tape
(helically applied) and overlaying black PVC jacket are applied over the cable core. The conductor
Class B compressed concentric lay, filled stranded 1350 aluminum. Conductor shield is an extruded
semi-conducting thermosetting polymeric stress control layer. Insulation is extruded, TRXLPE (TreeRetardant Cross-linked Polyethylene). Insulation shield is an extruded semi-conducting thermosetting layer, clean and free-stripping from insulation. The metallic shield is flat uncoated 5-mil-thick
copper tape helically applied with minimum 25% overlap. The jacket is sunlight and moisture resistant black, non-conducting PVC (Polyvinyl Chloride).

Standards
ANSI/ICEA S-97-682
UL-1072 MV-105
AEIC CS8 as applicable for TRXLPE (Tree-Retardant Cross-linked Polyethylene) insulated shielded
power cable
ICEA T-31-610
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
Temperature Rating
Normal..............................105C
Emergency*.................... 140C
Short Circuit.................... 250C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.
Options
Copper conductors
CPE (chlorinated polyethylene) Jacket conforming to the requirements specified for chlorinated
polyethylene jackets in ICEA. The average thickness shall be in accordance with Table 4-3 of ICEA
and the minimum spot thickness shall be not less than 80% of the average thickness
Non-filled conductor
Compact strand conductor
For information on conductor sizes or voltage ratings not shown in the tables, contact your AWG
sales representative or email: sales@buyawg.com.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

314
20160110

MEDIUM VOLTAGE
CABLES

Features
Triple-extruded for clean interfaces
Dry nitrogen cure for enhanced performance
Class 10,000 environment utilized for material handling
Excellent moisture resistance
High dielectric strength
Low dielectric loss
Excellent resistance to treeing
Clean-stripping insulation shield
Sunlight and moisture resistant
Approved for CT use 1/0 and larger

PowerGuard 5kV-35kV Aluminum TR-XLPE Tape Shield


PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE
CABLES

Item #

Compressed Nominal Diameter Diameter Diameter


Conductor Insulation Insulation Insulation 5 mil CU
Aluminum Thickness
Min
Max
Tape
Size/No of Wires (mil)
(in)1
(in)1
(in)1

115 Mils TRXLPE 5kV 133% OR 8kV 100%


A2-01MV5UT10501
2/7
A1/0-01MV5UT10501
1/0 / 19
A2/0-01MV5UT10501
2/0 / 19
A3/0-01MV5UT10501
3/0 / 19
A4/0-01MV5UT10501
4/0 / 19
A250-01MV5UT10501
250 / 37
A350-01MV5UT10501
350 / 37
A500-01MV5UT10501
500 / 37
A750-01MV5UT10501
750 / 61
A1000-01MV5UT10501 1000 / 61
175 Mils TRXLPE 15kV 100%
A2-01MV15GT10501
2/7
A1-01MV15GT10501
1 / 19
A1/0-01MV15GT10501
1/0 / 19
A2/0-01MV15GT10501
2/0 / 19
A3/0-01MV15GT10501
3/0 / 19
A4/0-01MV15GT10501
4/0 / 19
A250-01MV15GT10501 250 / 37
A350-01MV15GT10501 350 / 37
A500-01MV15GT10501 500 / 37
A750-01MV15GT10501 750 / 61
A1000-01MV15GT1051 1000 / 61
220 Mils TRXLPE 15kV 133%
A2-01MV15UT10501
2/7
A1-01MV15UT10501
1 / 19
A1/0-01MV15UT10501
1/0 / 19
A2/0-01MV15UT10501
2/0 / 19
A3/0-01MV15UT10501
3/0 / 19
A4/0-01MV15UT10501
4/0 / 19
A250-01MV15UT10501 250 / 37
A350-01MV15UT10501 350 / 37
A500-01MV15UT10501 500 / 37
A750-01MV15UT10501 750 / 61
A1000-01MV15UT1051 1000 / 61

Diameter Nominal
PVC
Jacket
Jacket Thickness
(in)1
(in)1

Approx.
Weight
AL
(lb/Mft)1

Approx.
Weight
CU
(lb/Mft)1

Approx.
Weight
Total
(lb/Mft)1

Ampacity2 Ampacity2
Direct
in Duct
Buried

115
115
115
115
115
115
115
115
115
115

0.525
0.605
0.65
0.7
0.755
0.81
0.905
1.04
1.23
1.375

0.605
0.685
0.725
0.775
0.835
0.89
0.98
1.12
1.31
1.46

0.621
0.7
0.744
0.794
0.85
0.906
1.009
1.137
1.324
1.473

0.75
0.829
0.903
0.953
1.009
1.065
1.168
1.296
1.483
1.632

0.065
0.065
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08

62
99
125
158
199
234
329
468
703
937

44
49
53
56
60
64
71
81
94
104

289
357
426
482
549
640
754
954
1279
1584

165
215
245
280
320
350
425
520
655
760

125
165
185
210
240
275
330
405
510
610

175
175
175
175
175
175
175
175
175
175
175

0.635
0.675
0.715
0.76
0.81
0.865
0.92
1.015
1.15
1.34
1.485

0.72
0.76
0.8
0.845
0.895
0.95
1.005
1.1
1.235
1.425
1.575

0.741
0.78
0.82
0.864
0.914
0.97
1.026
1.129
1.257
1.444
1.593

0.87
0.939
0.979
1.023
1.073
1.129
1.185
1.288
1.416
1.603
1.812

0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.11

62
78
99
125
158
199
234
329
468
703
937

52
55
58
61
65
69
73
80
89
102
113

364
422
463
513
572
643
710
861
1070
1410
1822

165
190
215
245
280
320
350
425
520
655
760

125
145
165
185
210
240
275
330
405
510
610

220
220
220
220
220
220
220
220
220
220
220

0.725
0.765
0.805
0.85
0.9
0.955
1.01
1.105
1.24
1.43
1.575

0.815
0.855
0.895
0.935
0.985
1.045
1.1
1.19
1.33
1.52
1.67

0.831
0.87
0.91
0.954
1.004
1.06
1.116
1.219
1.347
1.534
1.683

0.99
1.029
1.069
1.113
1.163
1.219
1.275
1.378
1.506
1.693
1.902

0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.11

62
78
99
125
158
199
234
329
468
703
937

59
62
64
68
71
75
79
86
96
109
119

451
488
532
584
646
720
790
947
1163
1513
1939

165
190
215
245
280
320
350
425
520
650
760

125
145
165
185
210
240
275
330
405
510
610

(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46
kV and also meet the requirements of the latest revisions of AEIC CS8.
(2) Ampacity based on earth thermal resistivity of 90C-cm/watt, 105C conductor temp., 20C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each
end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means
mass.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
314
20160110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 5kV-35kV Aluminum TR-XLPE Tape Shield


PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item #

Compressed Nominal Diameter Diameter Diameter


Conductor Insulation Insulation Insulation 5 mil CU
Aluminum Thickness
Min
Max
Tape
Size/No of Wires (mil)
(in)1
(in)1
(in)1

Approx.
Weight
AL
(lb/Mft)1

Approx.
Weight
CU
(lb/Mft)1

Approx.
Weight
Total
(lb/Mft)1

Ampacity2 Ampacity2
Direct
in Duct
Buried

1 / 19
1/0 / 19
2/0 / 19
3/0 / 19
4/0 / 19
250 / 37
350 / 37
500 / 37
750 / 61
1000 / 61

260
260
260
260
260
260
260
260
260
260

0.835
0.875
0.92
0.97
1.025
1.08
1.175
1.31
1.5
1.645

0.925
0.965
1.01
1.06
1.115
1.175
1.265
1.405
1.595
1.74

0.95
0.99
1.034
1.084
1.14
1.196
1.299
1.427
1.614
1.763

1.109
1.149
1.193
1.243
1.299
1.355
1.458
1.586
1.833
1.982

0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.11
0.11

78
99
125
158
199
234
329
468
703
937

67
70
73
77
81
85
92
101
115
125

551
597
651
716
793
866
1027
1250
1707
2047

185
215
245
275
315
350
420
515
650
755

145
165
185
215
250
275
335
405
520
605

1/0 / 19
2/0 / 19
3/0 / 19
4/0 / 19
250 / 37
350 / 37
500 / 37
750 / 61
1000 / 61

345
345
345
345
345
345
345
345
345

1.045
1.09
1.14
1.195
1.25
1.345
1.48
1.67
1.815

1.145
1.119
1.24
1.295
1.35
1.445
1.58
1.77
1.92

1.16
1.204
1.254
1.31
1.366
1.469
1.597
1.784
1.933

1.319
1.363
1.413
1.469
1.525
1.628
1.816
2.003
2.152

0.08
0.08
0.08
0.08
0.08
0.08
0.11
0.11
0.11

99
125
158
199
234
329
468
703
937

82
85
89
93
97
104
113
127
137

748
807
877
960
1039
1212
1544
1934
2290

210
240
275
310
345
415
510
640
745

170
190
220
250
275
340
410
525
615

1/0 / 19
2/0 / 19
3/0 / 19
4/0 / 19
250 / 37
350 / 37
500 / 37
750 / 61
1000 / 61

420
420
420
420
420
420
420
420
420

1.198
1.242
1.292
1.348
1.394
1.497
1.625
1.816
1.965

1.318
1.362
1.412
1.468
1.514
1.617
1.745
1.936
2.085

1.318
1.362
1.412
1.468
1.514
1.617
1.745
1.936
2.085

1.478
1.522
1.572
1.628
1.674
1.777
1.965
2.156
2.305

0.08
0.08
0.08
0.08
0.08
0.08
0.11
0.11
0.11

99
125
158
199
234
329
468
703
937

92
95
99
104
108
116
126
142
153

967
1032
1109
1200
1381
1598
1865
2284
2666

210
240
275
310
345
415
510
640
745

170
190
220
250
275
340
410
525
615

(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46
kV and also meet the requirements of the latest revisions of AEIC CS8.
(2) Ampacity based on earth thermal resistivity of 90C-cm/watt, 105C conductor temp., 20C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each
end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means
mass.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

314
20160110

MEDIUM VOLTAGE
CABLES

260 Mils TRXLPE 25kV 100%


A1-01MV25GT10501
A1/0-01MV25GT10501
A2/0-01MV25GT10501
A3/0-01MV25GT10501
A4/0-01MV25GT10501
A250-01MV25GT10501
A350-01MV25GT10501
A500-01MV25GT10501
A750-01MV25GT10501
A1000-01MV25GT1051
345 Mils TRXLPE 35kV 100%
A1/0-01MV35GT10501
A2/0-01MV35GT10501
A3/0-01MV35GT10501
A4/0-01MV35GT10501
A250-01MV35GT10501
A350-01MV35GT10501
A500-01MV35GT10501
A750-01MV35GT10501
A1000-01MV35GT1051
420 Mils TRXLPE 35kV 133%
A1/0-01MV35UT10501
A2/0-01MV35UT10501
A3/0-01MV35UT10501
A4/0-01MV35UT10501
A250-01MV35UT10501
A350-01MV35UT10501
A500-01MV35UT10501
A750-01MV35UT10501
A1000-01MV35UT1051

Diameter Nominal
PVC
Jacket
Jacket Thickness
(in)1
(in)1

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

PowerGuard 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07
Applications
Medium voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods.
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart.
Installed in both exposed and concealed work, wet or dry locations, directly buried.
Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for
phase identification - 1C w/Red, 1C w/Blue, and 1C w/None.
Grounding Conductors: Three bare stranded copper conductor, one in each interstice.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

NOTES:
Ampacities are based on three phase operation
In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90C conductor temperature, 20C ambient temperature, earth RHO of 90C-cm/Watt, and 100% load factor,
and shields short-circuited.
Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90C conductor temperature,
and 40C ambient temperature, and shields grounded at one point only.
In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), Isolated in Air values noted above.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

316
20150519

MEDIUM VOLTAGE
CABLES

Standards
AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
ICEA S-93-639, 5-46 kV Shielded Power Cable
ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
UL 1072 MV-105
IEEE- IEEE 383 Flame Test
For 105C continuous, 140C emergency, 250C short-circuit operation.
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

PowerGuard 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE
CABLES

Item #

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

5kV Copper 100%


4-03MV5GT10501
4
2-03MV5GT10501
2
1-03MV5GT10501
1
1/0-03MV5GT10501
1/0
2/0-03MV5GT10501
2/0
3/0-03MV5GT10501
3/0
4/0-03MV5GT10501
4/0
250-03MV5GT10501
250
350-03MV5GT10501
350
500-03MV5GT10501
500
750-03MV5GT10501
750
1000-03MV5GT10501 1000
5kV Copper 133%
4-03MV5UT10501
4
2-03MV5UT10501
2
1-03MV5UT10501
1
1/0-03MV5UT10501
1/0
2/0-03MV5UT10501
2/0
3/0-03MV5UT10501
3/0
4/0-03MV5UT10501
4/0
250-03MV5UT10501
250
350-03MV5UT10501
350
500-03MV5UT10501
500
750-03MV5UT10501
750
1000-03MV5UT10501 1000

90
90
90
90
90
90
90
90
90
90
90
90

3
3
3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
7
7
7
6
5
4
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.45
0.51
0.55
0.59
0.64
0.69
0.74
0.8
0.9
1.03
1.22
1.37

0.51
0.57
0.61
0.65
0.69
0.74
0.8
0.85
0.95
1.1
1.29
1.44

1.32
1.44
1.53
1.61
1.71
1.88
2
2.11
2.34
2.65
3.12
3.44

1097
1412
1682
1948
2271
2812
3317
3761
4918
6668
9629
12287

10
11
11
12
12
14
15
15
17
19
22
25

100
135
155
175
200
230
265
290
355
430
530
600

105
140
160
185
215
250
285
320
395
485
615
705

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
7
7
7
6
5
4
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.5
0.56
0.6
0.64
0.69
0.74
0.79
0.85
0.95
1.08
1.27
1.42

0.56
0.62
0.66
0.7
0.74
0.79
0.85
0.9
1
1.15
1.34
1.49

1.42
1.55
1.64
1.78
1.88
1.99
2.11
2.22
2.44
2.76
3.22
3.55

1193
1515
1789
2158
2493
2941
3453
3903
5072
6839
9829
12504

10
11
12
13
14
14
15
16
18
20
23
25

100
135
155
175
200
230
265
290
355
430
530
600

105
140
160
185
215
250
285
320
395
485
615
705

8kV Copper 100%


4-03MV8GT10501
2-03MV8GT10501
1-03MV8GT10501
1/0-03MV8GT10501
2/0-03MV8GT10501
3/0-03MV8GT10501
4/0-03MV8GT10501
250-03MV8GT10501
350-03MV8GT10501
500-03MV8GT10501
750-03MV8GT10501
1000-03MV8GT10501

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
7
7
7
6
5
4
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.5
0.56
0.6
0.64
0.69
0.74
0.79
0.85
0.95
1.08
1.27
1.42

0.56
0.62
0.66
0.7
0.74
0.79
0.85
0.9
1
1.15
1.34
1.49

1.42
1.55
1.64
1.78
1.88
1.99
2.11
2.22
2.44
2.76
3.22
3.55

1193
1515
1789
2158
2493
2941
3453
3903
5072
6839
9829
12504

10
11
12
13
14
14
15
16
18
20
23
25

115
150
170
195
220
250
285
310
375
450
545
615

120
165
185
215
245
285
325
360
435
535
670
770

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
316
20150519

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07
Item #

8kV Copper 133%


2-03MV8UT10501
1-03MV8UT10501
1/0-03MV8UT10501
2/0-03MV8UT10501
3/0-03MV8UT10501
4/0-03MV8UT10501
250-03MV8UT10501
350-03MV8UT10501
500-03MV8UT10501
750-03MV8UT10501
1000-03MV8UT10501

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

140
140
140
140
140
140
140
140
140
140
140

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.61
0.65
0.69
0.74
0.79
0.84
0.9
1
1.13
1.32
1.47

0.67
0.71
0.75
0.79
0.84
0.9
0.95
1.05
1.2
1.39
1.54

1.66
1.8
1.89
1.99
2.09
2.22
2.33
2.55
2.93
3.33
3.66

1623
2002
2282
2622
3076
3594
4051
5232
7180
10034
12728

12
13
14
14
15
16
17
18
21
24
26

150
170
195
220
250
285
310
375
450
545
615

165
185
215
245
285
325
360
435
535
670
770

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

175
175
175
175
175
175
175
175
175
175
175

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.68
0.72
0.76
0.81
0.86
0.91
0.97
1.07
1.2
1.39
1.54

0.74
0.78
0.82
0.86
0.91
0.97
1.02
1.14
1.27
1.46
1.62

1.87
1.96
2.04
2.14
2.24
2.37
2.48
2.74
3.08
3.48
3.84

1888
2179
2466
2813
3275
3803
4268
5529
7447
10333
13138

14
14
15
15
16
17
18
20
22
25
27

150
170
195
220
250
285
310
375
450
545
615

165
185
215
245
285
325
360
435
535
670
770

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

220
220
220
220
220
220
220
220
220
220
220

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.77
0.81
0.85
0.9
0.95
1
1.06
1.16
1.29
1.48
1.63

0.83
0.87
0.91
0.95
1
1.06
1.13
1.23
1.36
1.55
1.71

2.06
2.15
2.24
2.33
2.44
2.56
2.71
2.99
3.27
3.68
4.04

2124
2424
2719
3075
3548
4088
4627
6018
7808
10733
13574

15
16
16
17
18
18
19
21
23
26
29

150
170
195
220
250
285
310
375
450
545
615

165
185
215
245
285
325
360
435
535
670
770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

316
20150519

MEDIUM VOLTAGE
CABLES

15kV Copper 100%


2-03MV15GT10501
1-03MV15GT10501
1/0-03MV15GT10501
2/0-03MV15GT10501
3/0-03MV15GT10501
4/0-03MV15GT10501
250-03MV15GT10501
350-03MV15GT10501
500-03MV15GT10501
750-03MV15GT10501
1000-03MV15GT10501
15kV Copper 133%
2-03MV15UT10501
1-03MV15UT10501
1/0-03MV15UT10501
2/0-03MV15UT10501
3/0-03MV15UT10501
4/0-03MV15UT10501
250-03MV15UT10501
350-03MV15UT10501
500-03MV15UT10501
750-03MV15UT10501
1000-03MV15UT10501

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

PowerGuard 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE
CABLES

Item #

25kV Copper 100%


1-03MV25GT10501
1/0-03MV25GT10501
2/0-03MV25GT10501
3/0-03MV25GT10501
4/0-03MV25GT10501
250-03MV25GT10501
350-03MV25GT10501
500-03MV25GT10501
750-03MV25GT10501
1000-03MV25GT10501
25kV Copper 133%
1/0-03MV25UT10501
2/0-03MV25UT10501
3/0-03MV25UT10501
4/0-03MV25UT10501
250-03MV25UT10501
350-03MV25UT10501
500-03MV25UT10501
35kV Copper 100%
1/0-03MV35GT10501
2/0-03MV35GT10501
3/0-03MV35GT10501
4/0-03MV35GT10501
250-03MV35GT10501
350-03MV35GT10501
500-03MV35GT10501
35kV Copper 133%
1/0-03MV35UT10501
2/0-03MV35UT10501
3/0-03MV35UT10501
4/0-03MV35UT10501
250-03MV35UT10501
350-03MV35UT10501
500-03MV35UT10501

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

1
1/0
2/0
3/0
4/0
250
350
500
750
1000

260
260
260
260
260
260
260
260
260
260

3
3
3
3
3
3
3
3
3
3

8
8
8
7
7
7
6
5
4
4

0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.89
0.93
0.98
1.03
1.08
1.14
1.24
1.37
1.56
1.71

0.95
0.99
1.03
1.1
1.16
1.21
1.31
1.44
1.64
1.79

2.32
2.41
2.5
2.65
2.77
2.94
3.16
3.45
3.89
4.21

2657
2960
3324
3868
4421
5073
6330
8144
11193
13978

17
17
18
19
20
21
23
25
28
30

170
195
220
250
285
310
375
450
545
615

185
215
245
285
325
360
435
535
670
770

1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345

3
3
3
3
3
3
3

8
8
7
7
7
6
5

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.11
1.15
1.2
1.26
1.31
1.41
1.54

1.18
1.22
1.27
1.33
1.38
1.48
1.63

2.88
2.97
3.08
3.21
3.32
3.54
3.86

3761
4151
4662
5245
5762
7060
9015

21
21
22
23
24
25
27

195
220
250
285
310
375
450

215
245
285
325
360
435
535

1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345

3
3
3
3
3
3
3

8
8
7
7
7
6
5

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.11
1.15
1.2
1.26
1.31
1.41
1.54

1.18
1.22
1.27
1.33
1.38
1.48
1.63

2.88
2.97
3.08
3.21
3.32
3.54
3.86

3761
4151
4662
5245
5762
7060
9015

21
21
22
23
24
25
27

195
220
250
285
310
375
450

215
245
285
325
360
435
535

1/0
2/0
3/0
4/0
250
350
500

420
420
420
420
420
420
420

3
3
3
3
3
3
3

8
8
7
7
7
6
5

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.26
1.3
1.35
1.41
1.46
1.57
1.7

1.33
1.38
1.43
1.48
1.54
1.65
1.78

3.21
3.31
3.41
3.54
3.65
3.91
4.19

4356
4761
5291
5895
6430
7854
9775

23
24
24
25
26
28
30

195
220
250
285
310
375
450

215
245
285
325
360
435
535

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
316
20150519

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07
Applications
Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods.
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart.
Installed in both exposed and concealed work, wet or dry locations, directly buried.
Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for
phase identification - 1C w/Red, 1C w/Blue, and 1C w/None.
Grounding Conductors: Three bare stranded copper conductor, one in each interstice.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

NOTES:
Ampacities are based on three Phase Operation
In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90C conductor temperature, 20C ambient temperature, earth RHO of 90C-cm/Watt, and 100% load factor,
and shields short-circuited.
Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90C conductor temperature,
and 40C ambient temperature, and shields grounded at one point only.
In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), Isolated in Air values noted above.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

317
20150519

MEDIUM VOLTAGE
CABLES

Standards
AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
ICEA S-93-639, 5-46 kV Shielded Power Cable
ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
UL 1072 MV-105
IEEE- IEEE 383 Flame Test
For 105C continuous, 140C emergency, 250C short-circuit operation.
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

PowerGuard 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE
CABLES

Item #

5kV Aluminum 100%


A4-03MV5GT10501
A2-03MV5GT10501
A1-03MV5GT10501
A1/0-03MV5GT10501
A2/0-03MV5GT10501
A3/0-03MV5GT10501
A4/0-03MV5GT10501
A250-03MV5GT10501
A350-03MV5GT10501
A500-03MV5GT10501
A750-03MV5GT10501
A1000-03MV5GT10501
5kV Aluminum 133%
A4-03MV5UT10501
A2-03MV5UT10501
A1-03MV5UT10501
A1/0-03MV5UT10501
A2/0-03MV5UT10501
A3/0-03MV5UT10501
A4/0-03MV5UT10501
A250-03MV5UT10501
A350-03MV5UT10501
A500-03MV5UT10501
A750-03MV5UT10501
A1000-03MV5UT10501
8kV Aluminum 100%
A4-03MV8GT10501
A2-03MV8GT10501
A1-03MV8GT10501
A1/0-03MV8GT10501
A2/0-03MV8GT10501
A3/0-03MV8GT10501
A4/0-03MV8GT10501
A250-03MV8GT10501
A350-03MV8GT10501
A500-03MV8GT10501
A750-03MV8GT10501
A1000-03MV8GT10501

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

90
90
90
90
90
90
90
90
90
90
90
90

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.45
0.51
0.55
0.59
0.64
0.69
0.74
0.8
0.9
1.03
1.22
1.37

0.51
0.57
0.61
0.65
0.69
0.74
0.8
0.85
0.95
1.1
1.29
1.44

1.32
1.44
1.53
1.61
1.77
1.88
2
2.11
2.34
2.65
3.12
3.44

833
993
1093
1218
1522
1705
1930
2131
2643
3424
4755
5886

10
11
11
12
13
14
15
15
17
19
22
25

80
105
120
140
160
180
205
230
280
340
425
495

81
110
125
145
170
195
225
250
310
385
495
585

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.5
0.56
0.6
0.64
0.69
0.74
0.79
0.85
0.95
1.08
1.27
1.42

0.56
0.62
0.66
0.7
0.74
0.79
0.85
0.9
1
1.15
1.34
1.49

1.42
1.55
1.64
1.78
1.88
1.99
2.11
2.22
2.44
2.76
3.22
3.55

929
1095
1200
1429
1645
1834
2066
2273
2797
3595
4955
6103

10
11
12
13
14
14
15
16
18
20
23
25

80
105
120
140
160
180
205
230
280
340
425
495

81
110
125
145
170
195
225
250
310
385
495
585

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.226
0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.5
0.56
0.6
0.64
0.69
0.74
0.79
0.85
0.95
1.08
1.27
1.42

0.56
0.62
0.66
0.7
0.74
0.79
0.85
0.9
1
1.15
1.34
1.49

1.42
1.55
1.64
1.78
1.88
1.99
2.11
2.22
2.44
2.76
3.22
3.55

929
1095
1200
1429
1645
1834
2066
2273
2797
3595
4955
6103

10
11
12
13
14
14
15
16
18
20
23
25

89
115
135
150
170
195
220
245
295
355
440
510

95
125
145
170
190
220
255
280
345
425
540
635

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
317
20150519

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07
Item #

8kV Aluminum 133%


A2-03MV8UT10501
A1-03MV8UT10501
A1/0-03MV8UT10501
A2/0-03MV8UT10501
A3/0-03MV8UT10501
A4/0-03MV8UT10501
A250-03MV8UT10501
A350-03MV8UT10501
A500-03MV8UT10501
A750-03MV8UT10501
A1000-03MV8UT10501

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

140
140
140
140
140
140
140
140
140
140
140

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.61
0.65
0.69
0.74
0.79
0.84
0.9
1
1.13
1.32
1.47

0.67
0.71
0.75
0.79
0.84
0.9
0.95
1.05
1.2
1.39
1.54

1.66
1.8
1.89
1.99
2.09
2.22
2.33
2.55
2.93
3.33
3.66

1204
1413
1553
1774
1969
2208
2421
2957
3936
5161
6327

12
13
14
14
15
16
17
18
21
24
26

115
135
150
170
195
220
245
295
355
440
510

125
145
170
190
220
255
280
345
425
540
635

175
175
175
175
175
175
175
175
175
175
175

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.68
0.72
0.76
0.81
0.86
0.91
0.97
1.07
1.2
1.39
1.54

0.74
0.78
0.82
0.86
0.91
0.97
1.02
1.14
1.27
1.46
1.62

1.87
1.96
2.04
2.14
2.24
2.37
2.48
2.74
3.08
3.48
3.84

1469
1590
1736
1965
2168
2416
2638
3254
4203
5459
6737

14
14
15
15
16
17
18
20
22
25
27

115
135
150
170
195
220
245
295
355
440
510

125
145
170
190
220
255
280
345
425
540
635

220
220
220
220
220
220
220
220
220
220
220

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.284
0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.77
0.81
0.85
0.9
0.95
1
1.06
1.16
1.29
1.48
1.63

0.83
0.87
0.91
0.95
1
1.06
1.13
1.23
1.36
1.55
1.71

2.06
2.15
2.24
2.33
2.44
2.56
2.71
2.99
3.27
3.68
4.04

1705
1834
1989
2227
2441
2701
2997
3743
4564
5859
7173

15
16
16
17
18
18
19
21
23
26
29

115
135
150
170
195
220
245
295
355
440
510

125
145
170
190
220
255
280
345
425
540
635

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

317
20150519

MEDIUM VOLTAGE
CABLES

15kV Aluminum 100%


A2-03MV15GT10501
2
A1-03MV15GT10501
1
A1/0-03MV15GT10501 1/0
A2/0-03MV15GT10501 2/0
A3/0-03MV15GT10501 3/0
A4/0-03MV15GT10501 4/0
A250-03MV15GT10501 250
A350-03MV15GT10501 350
A500-03MV15GT10501 500
A750-03MV15GT10501 750
A1000-03MV15GT10501 1000
15kV Aluminum 133%
A2-03MV15UT10501
2
A1-03MV15UT10501
1
A1/0-03MV15UT10501 1/0
A2/0-03MV15UT10501 2/0
A3/0-03MV15UT10501 3/0
A4/0-03MV15UT10501 4/0
A250-03MV15UT10501 250
A350-03MV15UT10501 350
A500-03MV15UT10501 500
A750-03MV15UT10501 750
A1000-03MV15UT10501 1000

Overall
Jacket
(in)

PowerGuard 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield


w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE
CABLES

Item #

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

25kV Aluminum 100%


A1-03MV25GT10501
1
A1/0-03MV25GT10501 1/0
A2/0-03MV25GT10501 2/0
A3/0-03MV25GT10501 3/0
A4/0-03MV25GT10501 4/0
A250-03MV25GT10501 250
A350-03MV25GT10501 350
A500-03MV25GT10501 500
A750-03MV25GT10501 750
A1000-03MV25GT10501 1000
25kV Aluminum 133%
A1/0-03MV25UT10501 1/0
A2/0-03MV25UT10501 2/0
A3/0-03MV25UT10501 3/0
A4/0-03MV25UT10501 4/0
A250-03MV25UT10501 250
A350-03MV25UT10501 350
A500-03MV25UT10501 500
35kV Aluminum 100%
A1/0-03MV35GT10501 1/0
A2/0-03MV35GT10501 2/0
A3/0-03MV35GT10501 3/0
A4/0-03MV35GT10501 4/0
A250-03MV35GT10501 250
A350-03MV35GT10501 350
A500-03MV35GT10501 500
35kV Aluminum 133%
A1/0-03MV35UT10501 1/0
A2/0-03MV35UT10501 2/0
A3/0-03MV35UT10501 3/0
A4/0-03MV35UT10501 4/0
A250-03MV35UT10501 250
A350-03MV35UT10501 350
A500-03MV35UT10501 500

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

260
260
260
260
260
260
260
260
260
260

3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
8
7
6
5
4

0.324
0.364
0.408
0.458
0.515
0.561
0.664
0.794
0.974
1.124

0.89
0.93
0.98
1.03
1.08
1.14
1.24
1.37
1.56
1.71

0.95
0.99
1.03
1.1
1.16
1.21
1.31
1.44
1.64
1.79

2.32
2.41
2.5
2.65
2.77
2.94
3.16
3.45
3.89
4.21

2068
2230
2476
2761
3034
3444
4055
4900
6319
7577

17
17
18
19
20
21
23
25
28
30

135
150
170
195
220
245
295
355
440
510

145
170
190
220
255
280
345
425
540
635

345
345
345
345
345
345
345

3
3
3
3
3
3
3

10
8
8
8
8
7
6

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.11
1.15
1.2
1.26
1.31
1.41
1.54

1.18
1.22
1.27
1.33
1.38
1.48
1.63

2.88
2.97
3.08
3.21
3.32
3.54
3.86

3031
3303
3555
3859
4132
4785
5771

21
21
22
23
24
25
27

150
170
195
220
245
295
355

170
190
220
255
280
345
425

345
345
345
345
345
345
345

3
3
3
3
3
3
3

10
8
8
8
8
7
6

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.11
1.15
1.2
1.26
1.31
1.41
1.54

1.18
1.22
1.27
1.33
1.38
1.48
1.63

2.88
2.97
3.08
3.21
3.32
3.54
3.86

3031
3303
3555
3859
4132
4785
5771

21
21
22
23
24
25
27

150
170
195
220
245
295
355

170
190
220
255
280
345
425

420
420
420
420
420
420
420

3
3
3
3
3
3
3

10
8
8
8
8
7
6

0.364
0.408
0.458
0.515
0.561
0.664
0.794

1.26
1.3
1.35
1.41
1.46
1.57
1.7

1.33
1.38
1.43
1.48
1.54
1.65
1.78

3.21
3.31
3.41
3.54
3.65
3.91
4.19

3626
3914
4184
4509
4800
5580
6531

23
24
24
25
26
28
30

150
170
195
220
245
295
355

170
190
220
255
280
345
425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
317
20150519

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard 15kV 133% Shielded Power Cable


AL Conductor 220 mils EPR Copper Tape
PVC Jacket MV-105
Applications
For installation in tray, trough, conduit, ducts,
aerial and direct buried as allowed by the NEC.
The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may
operate continuously in wet or dry locations at
conductor temperatures not exceeding 105C, at
not more than 140C. for emergency overload
conditions and 250C during short circuits. Suitable for systems rated 15 kV 100% insulation
level (grounded systems). Suitable for Direct
Burial. Sunlight Resistant.
Construction
Aluminum concentrically stranded compressed
conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry cured; bare copper tape shielded; surface
printed black PVC jacket.

A2-01PC15EPPU2
A1/0-01PC15EPPU2
A2/0-01PC15EPPU2
A4/0-01PC15EPPU2
A250-01PC15EPPU2
A350-01PC15EPPU2
A500-01PC15EPPU2
A750-01PC15EPPU2
A1000-01PC15EPPU2

Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC
Section 392.13; operating at 105C conductor,
at an ambient temperature of 40C.
Buried Duct: Three cables per duct operating
at 105C conductor, 20C ground ambient,
earth = 90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40C; operating at 105C conductor (NEC Table 310.73).

Size/AWG

Insulation
Thickness
(in)

Conductor
Diameter
(in)

Insulation
Diameter
(in)

Overall
Diameter
(in)

Approx.
Weight
lb/MFT

Insulation
Shield
(in)

2
1/0
2/0
4/0
250
350
500
750
1000

.220
.220
.220
.220
.220
.220
.220
.220
.220

.266
.336
.379
.479
.522
.622
.742
.917
1.071

0.74
0.81
0.86
0.96
1.01
1.11
1.23
1.41
1.57

0.96
1.03
1.08
1.18
1.23
1.33
1.45
1.63
1.84

484
566
620
761
834
992
1216
1574
2028

0.80
0.87
0.91
1.01
1.06
1.16
1.28
1.47
1.62

Ampacity
(Amps)
105C
in Duct
130
165
190
245
270
330
400
490
565

Ampacity
(Amps)
105C
in Air
170
225
260
350
385
480
600
780
940

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

319
20160302

MEDIUM VOLTAGE
CABLES

Item #

Standards
National Electrical Code (NEC)
UL-1072 MV-105
ICEA S-93-639/NEMA WC74
ICEA S-97-682
AEIC CS8
UL listed as Type MV-105 for use in accordance
with NEC
Sizes 1/0 AWG and larger are listed and
marked Sunlight-Resistant FOR CT USE in
accordance with NEC

MEDIUM VOLAGE
CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ARMORED CABLES
Table of Contents
UL Type MC Two Conductor Aluminum with Ground PVC Jacket 600V ............................236
UL Type MC Three Conductor Aluminum with Ground PVC Jacket 600V .........................237
UL Type MC Four Conductor Aluminum with Ground PVC Jacket 600V...........................238
UL Type MC Two Conductor Aluminum with Ground PVC Jacket 2kV ..............................235
PowerGuard Armored Copper Three Conductor 5kV-35kV .............................................903
PowerGuard Armored Aluminum Three Conductor 5kV-35kV .........................................904
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 1/C.....................................................................................................905
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 2/C.....................................................................................................906
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 3/C.....................................................................................................907
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 4/C.....................................................................................................908
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 5/C.....................................................................................................909
UL Type MC Copper Conductor with Ground PVC Jacket 600V .........................................910

ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

900
20160220

ARMORED CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

UL Type MC Two Conductor Aluminum with Ground


PVC Jacket 600V
Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray
and outdoor exposure. The PVC jacket is free of
harmful heavy metals in compliance with RoHS,
Directive 2002/95/EC.
Run from the combiner box to the inverter
Suitable for rooftop solar applications
Outdoors
In wet locations (Type XHHW-2 , or RHW-2
conductors)
Direct buried
Encased in concrete
Hazardous locations
Strong, but lightweight alloy armor resists
damage
Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
More flexible than conduit
Factory tested engineered product that protects conductors from damage during installation
Meets or exceeds requirements of the NEC, as
well as applicable UL Standards.
Construction
Stranded Aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item #

Conductor
Size
AWG/
kcmil

Grounding
Conductor
AWG/
kcmil

Cable
Diameter
Under Armor
(in)

Cable
Diameter
Over Armor
(in)

Cable
Diameter
Over PVC
Jacket
(in)

Cable
Weight
(lb/MFT)

6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
750

8
6
6
4
4
4
4
2
2
2
2
1
1
1/0

0.56
0.65
0.76
0.86
0.93
1.01
1.11
1.21
1.34
1.44
1.53
1.62
1.77
2.18

0.75
0.84
0.95
1.05
1.12
1.21
1.3
1.41
1.6
1.7
1.79
1.88
2.03
2.43

0.85
0.94
1.05
1.15
1.22
1.31
1.4
1.51
1.72
1.82
1.91
2
2.15
2.58

243.5
306.5
383.9
472.9
537.5
626.4
723.1
864.8
1048
1180.5
1310.3
1431.2
1674.6
2417

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

236
20140924

ARMORED CABLES

A6-02AIA-WG-600V
A4-02AIA-WG-600V
A2-02AIA-WG-600V
A1-02AIA-WG-600V
A1/0-02AIA-WG-600V
A2/0-02AIA-WG-600V
A3/0-02AIA-WG-600V
A4/0-02AIA-WG-600V
A250-02AIA-WG-600V
A300-02AIA-WG-600V
A350-02AIA-WG-600V
A400-02AIA-WG-600V
A500-02AIA-WG-600V
A750-02AIA-WG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare
aluminum alloy (AA-8000) compacted stranded
conductor. Phase and grounding conductors are
cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape
and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound
jacket.
Standards
Single conductors are rated XHHW-2 600V,
and CT Use 1/0 AWG and larger. Additional
UL Type PV available upon request.
Aluminum armor is rated for Direct Burial,
using 6 AWG and larger conductors, with
overall jacket
UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in
Articles 501, 502, 503 and 504
UL 1569, Metal Clad Cables
UL 44, Rubber-Insulated wires and cables
ICEA S-95-658 Standard for Non-shielded
Power Cables Rated 2000 volts or less

ARMORED CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
.

UL Type MC Three Conductor Aluminum with Ground


PVC Jacket 600V
Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray
and outdoor exposure. The PVC jacket is free of
harmful heavy metals in compliance with RoHS,
Directive 2002/95/EC.
Run from the combiner box to the inverter
Suitable for rooftop solar applications
Outdoors
In wet locations (Type XHHW-2 , or RHW-2
conductors)
Direct buried
Encased in concrete
Hazardous locations
Strong, but lightweight alloy armor resists
damage
Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
More flexible than conduit
Factory tested engineered product that protects conductors from damage during installation
Meets or exceeds requirements of the NEC, as
well as applicable UL Standards
Construction
Stranded Aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item #

Conductor
Size
AWG/
kcmil

Grounding
Conductor
AWG/
kcmil

Cable
Diameter
Under Armor
(in)

Cable
Diameter
Over Armor
(in)

Cable
Diameter
Over PVC
Jacket
(in)

Cable
Weight
(lb/MFT)

4
2
1
1/0
2/0
3/0
40
250
300
350
400
500
600
700
750
900

6
6
4
4
4
4
2
2
2
2
2
1
1
1/0
1/0
250

0.68
0.77
0.90
0.96
1.05
1.13
1.27
1.40
1.51
1.61
1.70
1.87
2.10
2.24
2.30
2.50

0.09
1.00
1.12
1.18
1.28
1.36
1.55
1.69
1.79
1.89
1.99
2.15
2.38
2.52
2.59
2.78

1.00
1.09
1.22
1.28
1.38
1.46
1.67
1.81
1.91
2.01
2.11
2.72
2.53
2.67
2.74
2.93

380
482
595
691
813
950
1176
1381
1570
1755
1919
2269
2766
3134
3306
3959

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

237
20140921

ARMORED CABLES

A4-03AIA-WG-600V
A2-03AIA-WG-600V
A1-03AIA-WG-600V
A1/0-03AIA-WG-600V
A2/0-03AIA-WG-600V
A3/0-03AIA-WG-600V
A40-03AIA-WG-600V
A250-03AIA-WG-600V
A300-03AIA-WG-600V
A350-03AIA-WG-600V
A400-03AIA-WG-600V
A500-03AIA-WG-600V
A600-03AIA-WG-600V
A700-03AIA-WG-600V
A750-03AIA-WG-600V
A900-03AIA-WG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare
aluminum alloy (AA-8000)compacted stranded
conductor. Phase and grounding conductors are
cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape
and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound
jacket.
Specifications
Single conductors are rated XHHW-2 600V,
and CT Use 1/0 AWG and larger. Additional
UL Type PV available upon request.
Aluminum armor is rated for Direct Burial,
using 6 AWG and larger conductors, with
overall jacket
UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in
Articles 501, 502, 503 and 504
UL 1569, Metal Clad Cables
UL 44, Rubber-Insulated wires and cables
ICEA S-95-658 Standard for Non-shielded
Power Cables Rated 2000 volts or less

ARMORED CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

UL Type MC Four Conductor Aluminum with Ground


PVC Jacket 600V
Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray
and outdoor exposure. The PVC jacket is free of
harmful heavy metals in compliance with RoHS,
Directive 2002/95/EC.
Run from the combiner box to the inverter
Suitable for rooftop solar applications
Outdoors
In wet locations (Type XHHW-2 , or RHW-2
conductors)
Direct buried
Encased in concrete
Hazardous locations
Strong, but lightweight alloy armor resists
damage
Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
More flexible than conduit
Factory tested engineered product that protects conductors from damage during installation
Meets or exceeds requirements of the NEC, as
well as applicable UL Standards
Construction
Stranded Aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item #

Conductor
Size
AWG/
kcmil

Grounding
Conductor
AWG/
kcmil

Cable
Diameter
Under Armor
(in)

Cable
Diameter
Over Armor
(in)

Cable
Diameter
Over PVC
Jacket
(in)

Cable
Weight
(lb/MFT)

6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
700
750
750
900
900

6
6
6
4
4
4
4
2
1
1
1/0
1/0
2/0
250
2/0
400
2/0
3/0
750
250
900

0.70
0.77
0.89
1.03
1.11
1.19
1.32
1.46
1.60
1.70
1.83
1.91
2.11
2.25
2.35
2.61
2.58
2.60
3.04
2.84
3.32

0.92
1.04
1.10
1.25
1.34
1.41
1.58
1.73
1.89
1.99
2.11
2.20
2.39
2.54
2.67
2.89
2.86
2.86
3.30
3.12
3.60

1.02
1.09
1.20
1.35
1.43
1.51
1.70
1.85
2.01
2.11
2.23
2.32
2.54
2.69
2.79
3.01
3.01
3.01
3.50
3.29
3.77

377
474
617
757
871
1071
1235
1480
1730
1970
2231
2469
3028
3166
3591
3886
4043
4300
4998
5087
5844

ARMORED CABLES

A6-04AIA-WG-600V
A4-04AIA-WG-600V
A2-04AIA-WG-600V
A1-04AIA-WG-600V
A1/0-04AIA-WG-600V
A2/0-04AIA-WG-600V
A3/0-04AIA-WG-600V
A40-04AIA-WG-600V
A250-04AIAWG-600V
A300-04AIAWG-600V
A350-04AIAWG-600V
A400-04AIAWG-600V
A500-04AIAWG-600V
A600-04AIAWG-600V
A700-04AIAWG-600V
A750-04AIAWG-600V
A700-04AIAWG-600V
A750-04AIAWG-600V
A750-04AIAWG-600V
A900-04AIAWG-600V
A900-04AIAWG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare
aluminum alloy (AA-8000) compacted stranded
conductor. Phase and grounding conductors are
cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape
and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound
jacket.
Specifications
Single conductors are rated XHHW-2 600V,
and CT Use 1/0 AWG and larger. Additional
UL Type PV available upon request.
Aluminum armor is rated for Direct Burial,
using 6 AWG and larger conductors, with
overall jacket
UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in
Articles 501, 502, 503 and 504
UL 1569, Metal Clad Cables
UL 44, Rubber-Insulated wires and cables
ICEA S-95-658 Standard for Non-shielded
Power Cables Rated 2000 volts or less

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

238
20141016

ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

UL Type MC Two Conductor Aluminum with Ground


PVC Jacket 2kV
Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray
and outdoor exposure. The PVC jacket is free of
harmful heavy metals in compliance with RoHS,
Directive 2002/95/EC.
Run from the combiner box to the inverter
Suitable for rooftop solar applications
Outdoors
In wet locations (Type XHHW-2 , or RHW-2
conductors)
Direct buried
Encased in concrete
Hazardous locations
Strong, but lightweight alloy armor resists
damage
Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
More flexible than conduit
Factory tested engineered product that protects conductors from damage during installation
Meets or exceeds requirements of the NEC, as
well as applicable UL Standards.
Construction
Stranded Aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item #

Specifications
Single conductors are rated XHHW-2 600V,
and CT Use 1/0 AWG and larger. Additional UL
Type PV available upon request.
Aluminum armor is rated for Direct Burial,
using 6 AWG and larger conductors, with
overall jacket
UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in
Articles 501, 502, 503 and 504
UL 1569, Metal Clad Cables
UL 44, Rubber-Insulated wires and cables
ICEA S-95-658 Standard for Non-shielded
Power Cables Rated 2000 volts or less

Conductor
Size
AWG/
kcmil

Grounding
Conductor
AWG/
kcmil

Cable
Diameter
Under Armor
(in)

Cable
Diameter
Over Armor
(in)

Cable
Diameter
Over PVC
Jacket
(in)

Cable
Weight
(lb/MFT)

6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
750

8
6
6
4
4
4
4
2
2
2
2
1
1
1/0

0.66
0.75
0.86
1.00
1.07
1.15
1.25
1.35
1.50
1.60
1.69
1.78
1.93
2.34

0.85
0.94
1.05
1.19
1.27
1.35
1.44
1.61
1.76
1.86
1.95
2.04
2.19
2.59

0.95
1.04
1.15
1.29
1.37
1.45
1.54
1.73
1.88
1.98
2.07
2.16
2.31
2.74

284.9
351.1
432.5
540.6
626.8
709.0
810.3
1014.4
1165.3
1303.4
1438.4
1564.2
1816.2
2585.7

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

235
20140921

ARMORED CABLES

A6-02AIA-WG-2KV
A4-02AIA-WG-2KV
A2-02AIA-WG-2KV
A1-02AIA-WG-2KV
A1/0-02AIA-WG-2KV
A2/0-02AIA-WG-2KV
A3/0-02AIA-WG-2KV
A4/0-02AIA-WG-2KV
A250-02AIA-WG-2KV
A300-02AIA-WG-2KV
A350-02AIA-WG-2KV
A400-02AIA-WG-2KV
A500-02AIA-WG-2KV
A750-02AIA-WG-2KV

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare
aluminum alloy (AA-8000)compacted stranded
conductor. Phase and grounding conductors are
cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape
and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound
jacket.

ARMORED CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

PowerGuard Armored 5kV-35kV Copper 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Applications
Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to
labor-intensive cable in conduit wiring methods
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart
Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded
in concrete
Construction
Conductor: Class A or B Compressed concentric stranded copper conductor. Optional water-blocking.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in
ANSI/ICEA S-94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap
Ground Wire: Three bare copper ground wires placed at the interstice of the conductor.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Armor: Aluminum Interlocked Armor applied over the binder tape of the cable core
Jacket: Black, sunlight resistant, flame retardant PVC jacket

NOTES:
The above dimensions are approximate and subject to normal manufacturing tolerances.
Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table
310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105C conductor temperature,
20C ambient temperature, earth RHO of 90C-cm/Watt, and 100% load factor, and shields shortcircuited. Isolated in Air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105C conductor
temperature, and 40C ambient temperature, and shields grounded at one point only. In Cable
Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), Isolated in Air values noted above.
Insulated cables are capable of operating at 105C. However, the maximum operating temperature of the cable should be based on the maximum operating temperature of the cable accessories to be used.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

903
20140921

ARMORED CABLES

Specifications
AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
ICEA S-93-639, 5-46 kV Shielded Power Cable
ICEA S-97-682, Utility Shielded Power Cable Rated 5-46kV
UL-1072 MV-105
UL-1569, Metal Clad Cables
IEEE 383 Flame Test
For 105C continuous, 140C emergency, 250C short-circuit operation.
UL MC-HL available upon request

PowerGuard Armored 5kV-35kV Copper 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

ARMORED CABLES

Item #

5kV Copper 100%


2-03AIAPC5GT105
1-03AIAPC5GT105
1/0-03AIAPC5GT105
2/0-03AIAPC5GT105
3/0-03AIAPC5GT105
4/0-03AIAPC5GT105
250-03AIAPC5GT105
350-03AIAPC5GT105
500-03AIAPC5GT105
750-03AIAPC5GT105
1000-03AIAPC5GT105
5kV Copper 133%
4-03AIAPC5UT105
2-03AIAPC5UT105
1-03AIAPC5UT105
1/0-03AIAPC5UT105
2/0-03AIAPC5UT105
3/0-03AIAPC5UT105
4/0-03AIAPC5UT105
250-03AIAPC5UT105
350-03AIAPC5UT105
500-03AIAPC5UT105
750-03AIAPC5UT105
1000-03AIAPC5UT105
8kV Copper 100%
4-03AIAPC8GT105
2-03AIAPC8GT105
1-03AIAPC8GT105
1/0-03AIAPC8GT105
2/0-03AIAPC8GT105
3/0-03AIAPC8GT105
4/0-03AIAPC8GT105
250-03AIAPC8GT105
350-03AIAPC8GT105
500-03AIAPC8GT105
750-03AIAPC8GT105
1000-03AIAPC8GT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

90
90
90
90
90
90
90
90
90
90
90

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.5
0.53
0.57
0.61
0.66
0.71
0.76
0.86
0.98
1.16
1.32

0.56
0.59
0.63
0.67
0.71
0.77
0.82
0.92
1.05
1.24
1.39

1.58
1.68
1.77
1.86
1.96
2.08
2.19
2.44
2.73
3.14
3.48

1585
1829
2111
2540
2951
3458
3914
5146
6898
9832
12524

12
12
13
14
14
15
16
18
20
23
25

145
165
190
220
250
285
315
380
460
570
645

154
180
205
240
280
320
355
440
545
685
790

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
7
7
7
6
5
4
4

0.215
0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.5
0.55
0.58
0.62
0.66
0.71
0.76
0.81
0.91
1.03
1.21
1.37

0.56
0.61
0.64
0.68
0.72
0.76
0.82
0.87
0.97
1.1
1.29
1.44

1.58
1.71
1.78
1.89
1.97
2.07
2.19
2.3
2.54
2.84
3.25
3.59

1381
1740
1959
2299
2684
3102
3617
4080
5329
7101
10062
12776

12
12
13
14
14
15
16
17
18
20
23
26

110
145
165
190
220
250
285
315
380
460
570
645

115
154
180
205
240
280
320
355
440
545
685
790

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
8
8
8
7
7
7
6
5
4
4

0.215
0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.5
0.55
0.58
0.62
0.66
0.71
0.76
0.81
0.91
1.03
1.21
1.37

0.56
0.61
0.64
0.68
0.72
0.76
0.82
0.87
0.97
1.1
1.29
1.44

1.58
1.71
1.78
1.89
1.97
2.07
2.19
2.3
2.54
2.84
3.25
3.59

1381
1740
1959
2299
2684
3102
3617
4080
5329
7101
10062
12776

12
12
13
14
14
15
16
17
18
20
23
26

125
160
185
210
235
270
305
335
400
485
585
660

135
185
210
240
275
315
360
400
490
600
745
860

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
903
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard Armored 5kV-35kV Copper 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Item #

8kV Copper 133%


2-03AIAPC8UT105
1-03AIAPC8UT105
1/0-03AIAPC8UT105
2/0-03AIAPC8UT105
3/0-03AIAPC8UT105
4/0-03AIAPC8UT105
250-03AIAPC8UT105
350-03AIAPC8UT105
500-03AIAPC8UT105
750-03AIAPC8UT105
1000-03AIAPC8UT105

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

140
140
140
140
140
140
140
140
140
140
140

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.6
0.63
0.67
0.71
0.76
0.81
0.86
0.96
1.08
1.26
1.42

0.66
0.69
0.73
0.77
0.81
0.87
0.92
1.02
1.15
1.34
1.49

1.82
1.91
2
2.08
2.18
2.3
2.44
2.65
2.95
3.36
3.69

1873
2149
2446
2836
3260
3783
4321
5519
7310
10299
13035

13
14
15
15
16
17
18
19
21
24
26

160
185
210
235
270
305
335
400
485
585
660

185
210
240
275
315
360
400
490
600
745
860

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

175
175
175
175
175
175
175
175
175
175
175

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.67
0.7
0.74
0.78
0.83
0.88
0.93
1.03
1.15
1.33
1.49

0.73
0.76
0.8
0.84
0.88
0.94
0.99
1.1
1.22
1.41
1.58

1.99
2.06
2.15
2.23
2.33
2.48
2.59
2.84
3.1
3.51
3.88

2126
2358
2663
3060
3494
4097
4579
5864
7615
10644
13500

14
15
16
16
17
18
19
20
22
25
28

160
185
210
235
270
305
335
400
485
585
660

185
210
240
275
315
360
400
490
600
745
860

2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

220
220
220
220
220
220
220
220
220
220
220

3
3
3
3
3
3
3
3
3
3
3

10
8
8
8
7
7
7
6
5
4
4

0.266
0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.76
0.79
0.83
0.87
0.92
0.97
1.02
1.12
1.24
1.42
1.58

0.82
0.85
0.89
0.93
0.97
1.03
1.09
1.19
1.31
1.5
1.67

2.19
2.26
2.35
2.45
2.55
2.68
2.82
3.03
3.31
3.71
4.07

2406
2647
2962
3437
3886
4437
4998
6247
8090
11107
14006

16
16
17
18
18
19
20
22
24
26
29

160
185
210
235
270
305
335
400
485
585
660

185
210
240
275
315
360
400
490
600
745
860

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

903
20140921

ARMORED CABLES

15kV Copper 100%


2-03AIAPC15GT105
1-03AIAPC15GT105
1/0-03AIAPC15GT105
2/0-03AIAPC15GT105
3/0-03AIAPC15GT105
4/0-03AIAPC15GT105
250-03AIAPC15GT105
350-03AIAPC15GT105
500-03AIAPC15GT105
750-03AIAPC15GT105
1000-03AIAPC15GT105
15kV Copper 133%
2-03AIAPC15UT105
1-03AIAPC15UT105
1/0-03AIAPC15UT105
2/0-03AIAPC15UT105
3/0-03AIAPC15UT105
4/0-03AIAPC15UT105
250-03AIAPC15UT105
350-03AIAPC15UT105
500-03AIAPC15UT105
750-03AIAPC15UT105
1000-03AIAPC15UT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

PowerGuard Armored 5kV-35kV Copper 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Item #

ARMORED CABLES

25kV Copper 100%


1-03AIAPC25GT105
1/0-03AIAPC25GT105
2/0-03AIAPC25GT105
3/0-03AIAPC25GT105
4/0-03AIAPC25GT105
250-03AIAPC25GT105
350-03AIAPC25GT105
500-03AIAPC25GT105
750-03AIAPC25GT105
25kV Copper 133%
1-03AIAPC25UT105
1/0-03AIAPC25UT105
2/0-03AIAPC25UT105
3/0-03AIAPC25UT105
4/0-03AIAPC25UT105
250-03AIAPC25UT105
350-03AIAPC25UT105
500-03AIAPC25UT105
35kV Copper 100%
1/0-03AIAPC35GT105
2/0-03AIAPC35GT105
3/0-03AIAPC35GT105
4/0-03AIAPC35GT105
250-03AIAPC35GT105
350-03AIAPC35GT105
500-03AIAPC35GT105
35kV Copper 133%
1/0-03AIAPC35UT105
2/0-03AIAPC35UT105
3/0-03AIAPC35UT105
4/0-03AIAPC35UT105
250-03AIAPC35UT105
350-03AIAPC35UT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

1
1/0
2/0
3/0
4/0
250
350
500
750

260
260
260
260
260
260
260
260
260

3
3
3
3
3
3
3
3
3

8
8
8
7
7
7
6
5
4

0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742
0.917

0.87
0.91
0.95
1
1.05
1.1
1.2
1.32
1.5

0.93
0.97
1.01
1.07
1.13
1.17
1.27
1.39
1.59

2.46
2.55
2.63
2.76
2.88
2.99
3.22
3.48
3.91

2991
3319
3735
4260
4827
5334
6666
8480
11628

18
18
19
20
21
21
23
25
28

185
210
235
270
305
335
400
485
585

210
240
275
315
360
400
490
600
745

1
1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345
345

3
3
3
3
3
3
3
3

8
8
8
7
7
7
6
5

0.299
0.341
0.376
0.423
0.479
0.522
0.622
0.742

0.98
1.09
1.12
1.17
1.23
1.27
1.37
1.49

1.04
1.16
1.2
1.24
1.3
1.35
1.45
1.58

2.68
2.96
3.04
3.14
3.28
3.38
3.6
3.89

3326
4082
4517
5002
5658
6192
7516
9479

19
21
22
22
23
24
26
28

185
210
235
270
305
335
400
485

210
240
275
315
360
400
490
600

1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345

3
3
3
3
3
3
3

8
8
7
7
7
6
5

0.341
0.376
0.423
0.479
0.522
0.622
0.742

1.09
1.12
1.17
1.23
1.27
1.37
1.49

1.16
1.2
1.24
1.3
1.35
1.45
1.58

2.96
3.04
3.14
3.28
3.38
3.6
3.89

4082
4517
5002
5658
6192
7516
9479

21
22
22
23
24
26
28

210
235
270
305
335
400
485

240
275
315
360
400
490
600

1/0
2/0
3/0
4/0
250
350

420
420
420
420
420
420

3
3
3
3
3
3

8
8
7
7
7
6

0.341
0.376
0.423
0.479
0.522
0.622

1.24
1.27
1.32
1.38
1.42
1.52

1.31
1.35
1.39
1.45
1.5
1.61

3.3
3.38
3.48
3.6
3.71
3.96

4818
5269
5776
6397
6951
8409

24
24
25
26
26
28

210
235
270
305
335
400

240
275
315
360
400
490

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
903
201401916

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Applications
Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to
labor-intensive cable in conduit wiring methods
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart
Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded
in concrete
Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in
ANSI/ICEA S-94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap
Ground Wire: Three bare copper ground wires placed at the interstice of the conductor.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Armor: Aluminum Interlocked Armor applied over the binder tape of the cable core
Jacket: Black, sunlight resistant, flame retardant PVC jacket

NOTES:
The above dimensions are approximate and subject to normal manufacturing tolerances.
Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table
310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105C conductor temperature,
20C ambient temperature, earth RHO of 90C-cm/Watt, and 100% load factor, and shields shortcircuited. Isolated in Air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105C conductor
temperature, and 40C ambient temperature, and shields grounded at one point only. In Cable
Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), Isolated in Air values noted above.
Insulated cables are capable of operating at 105C. However, the maximum operating temperature of the cable should be based on the maximum operating temperature of the cable accessories to be used.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

904
20140921

ARMORED CABLES

Specifications
AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
ICEA S-93-639, 5-46 kV Shielded Power Cable
ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
UL-1072 MV-105
UL-1569, Metal Clad Cables
IEEE 383 Flame Test
For 105C continuous, 140C emergency, 250C short-circuit operation.
UL MC-HL available upon request

PowerGuard Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

ARMORED CABLES

Item #

5kV Aluminum 100%


A4-03AIAPC5GT105
A2-03AIAPC5GT105
A1-03AIAPC5GT105
A1/0-03AIAPC5GT105
A2/0-03AIAPC5GT105
A3/0-03AIAPC5GT105
A4/0-03AIAPC5GT105
A250-03AIAPC5GT105
A350-03AIAPC5GT105
A500-03AIAPC5GT105
A750-03AIAPC5GT105
A1000-03AIAPC5GT105
5kV Aluminum 133%
A4-03AIAPC5UT105
A2-03AIAPC5UT105
A1-03AIAPC5UT105
A1/0-03AIAPC5UT105
A2/0-03AIAPC5UT105
A3/0-03AIAPC5UT105
A4/0-03AIAPC5UT105
A250-03AIAPC5UT105
A350-03AIAPC5UT105
A500-03AIAPC5UT105
A750-03AIAPC5UT105
A1000-03AIAPC5UT105
8kV Aluminum 100%
A4-03AIAPC8GT105
A2-03AIAPC8GT105
A1-03AIAPC8GT105
A1/0-03AIAPC8GT105
A2/0-03AIAPC8GT105
A3/0-03AIAPC8GT105
A4/0-03AIAPC8GT105
A250-03AIAPC8GT105
A350-03AIAPC8GT105
A500-03AIAPC8GT105
A750-03AIAPC8GT105
A1000-03AIAPC8GT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

90
90
90
90
90
90
90
90
90
90
90
90

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.215
0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.45
0.5
0.53
0.57
0.61
0.66
0.71
0.76
0.86
0.98
1.16
1.32

0.51
0.56
0.59
0.63
0.67
0.71
0.77
0.82
0.92
1.05
1.24
1.39

1.47
1.58
1.68
1.75
1.87
1.96
2.08
2.19
2.44
2.73
3.14
3.48

1001
1165
1298
1431
1698
1887
2121
2338
2927
3734
4987
6177

11
12
12
13
14
14
15
16
18
20
23
25

86
110
130
150
170
195
220
245
310
365
460
535

90
120
140
160
185
215
250
280
345
430
550
650

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.215
0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.5
0.55
0.58
0.62
0.66
0.71
0.76
0.81
0.91
1.03
1.21
1.37

0.56
0.61
0.64
0.68
0.72
0.76
0.82
0.87
0.97
1.1
1.29
1.44

1.58
1.71
1.78
1.88
1.98
2.07
2.19
2.3
2.54
2.84
3.25
3.59

1117
1321
1429
1619
1843
2038
2280
2504
3110
3937
5218
6429

12
12
13
14
14
15
16
17
18
20
23
26

86
110
130
150
170
195
220
245
310
365
460
535

90
120
140
160
185
215
250
280
345
430
550
650

4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

115
115
115
115
115
115
115
115
115
115
115
115

3
3
3
3
3
3
3
3
3
3
3
3

10
10
10
10
8
8
8
8
7
6
5
4

0.215
0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.5
0.55
0.58
0.62
0.66
0.71
0.76
0.81
0.91
1.03
1.21
1.37

0.56
0.61
0.64
0.68
0.72
0.76
0.82
0.87
0.97
1.1
1.29
1.44

1.58
1.71
1.78
1.88
1.98
2.07
2.19
2.3
2.54
2.84
3.25
3.59

1117
1321
1429
1619
1843
2038
2280
2504
3110
3937
5218
6429

12
12
13
14
14
15
16
17
18
20
23
26

96
125
145
165
185
210
240
265
315
385
475
545

105
145
165
185
215
245
285
315
385
475
600
705

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
904
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

PowerGuard Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Item #

8kV Aluminum 133%


A2-03AIAPC8UT105
A1-03AIAPC8UT105
A1/0-03AIAPC8UT105
A2/0-03AIAPC8UT105
A3/0-03AIAPC8UT105
A4/0-03AIAPC8UT105
A250-03AIAPC8UT105
A350-03AIAPC8UT105
A500-03AIAPC8UT105
A750-03AIAPC8UT105
A1000-03AIAPC8UT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

140
140
140
140
140
140
140
140
140
140
140

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.6
0.63
0.67
0.71
0.76
0.81
0.86
0.96
1.08
1.26
1.42

0.66
0.69
0.73
0.77
0.81
0.87
0.92
1.02
1.15
1.34
1.49

1.82
1.91
1.99
2.08
2.18
2.3
2.44
2.65
2.95
3.36
3.69

1454
1619
1764
1995
2196
2446
2745
3300
4146
5455
6689

13
14
14
15
16
17
18
19
21
24
26

125
145
165
185
210
240
265
315
385
475
545

145
165
185
215
245
285
315
385
475
600
705

175
175
175
175
175
175
175
175
175
175
175

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.67
0.7
0.74
0.78
0.83
0.88
0.93
1.03
1.15
1.33
1.49

0.73
0.76
0.8
0.84
0.88
0.94
0.99
1.1
1.22
1.41
1.58

1.99
2.06
2.14
2.24
2.33
2.48
2.59
2.84
3.1
3.51
3.88

1706
1828
1980
2219
2430
2760
3003
3645
4451
5799
7153

14
15
15
16
17
18
19
20
22
25
28

125
145
165
185
210
240
265
315
385
475
545

145
165
185
215
245
285
315
385
475
600
705

220
220
220
220
220
220
220
220
220
220
220

3
3
3
3
3
3
3
3
3
3
3

10
10
10
8
8
8
8
7
6
5
4

0.266
0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917
1.071

0.76
0.79
0.83
0.87
0.92
0.97
1.02
1.12
1.24
1.42
1.58

0.82
0.85
0.89
0.93
0.97
1.03
1.09
1.19
1.31
1.5
1.67

2.19
2.26
2.34
2.46
2.55
2.68
2.82
3.03
3.31
3.71
4.07

1987
2116
2279
2597
2821
3100
3422
4027
4926
6262
7659

16
16
17
18
18
19
20
22
24
26
29

125
145
165
185
210
240
265
315
385
475
545

145
165
185
215
245
285
315
385
475
600
705

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

904
20140921

ARMORED CABLES

15kV Aluminum 100%


A2-03AIAPC15GT105
2
A1-03AIAPC15GT105
1
A1/0-03AIAPC15GT105 1/0
A2/0-03AIAPC15GT105 2/0
A3/0-03AIAPC15GT105 3/0
A4/0-03AIAPC15GT105 4/0
A250-03AIAPC15GT105 250
A350-03AIAPC15GT105 350
A500-03AIAPC15GT105 500
A750-03AIAPC15GT105 750
A1000-03AIAPC15GT1051000
15kV Aluminum 133%
A2-03AIAPC15UT105
2
A1-03AIAPC15UT105
1
A1/0-03AIAPC15UT105 1/0
A2/0-03AIAPC15UT105 2/0
A3/0-03AIAPC15UT105 3/0
A4/0-03AIAPC15UT105 4/0
A250-03AIAPC15UT105 250
A350-03AIAPC15UT105 350
A500-03AIAPC15UT105 500
A750-03AIAPC15UT105 750
A1000-03AIAPC15UT1051000

Overall
Jacket
(in)

PowerGuard Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire


TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8
Item #

ARMORED CABLES

25kV Aluminum 100%


A1-03AIAPC25GT105
A1/0-03AIAPC25GT105
A2/0-03AIAPC25GT105
A3/0-03AIAPC25GT105
A4/0-03AIAPC25GT105
A250-03AIAPC25GT105
A350-03AIAPC25GT105
A500-03AIAPC25GT105
A750-03AIAPC25GT105
25kV Aluminum 133%
A1/0-03AIAPC25UT105
A2/0-03AIAPC25UT105
A3/0-03AIAPC25UT105
A4/0-03AIAPC25UT105
A250-03AIAPC25UT105
A350-03AIAPC25UT105
A500-03AIAPC25UT105
35kV Aluminum 100%
A1/0-03AIAPC35GT105
A2/0-03AIAPC35GT105
A3/0-03AIAPC35GT105
A4/0-03AIAPC35GT105
A250-03AIAPC35GT105
A350-03AIAPC35GT105
A500-03AIAPC35GT105
35kV Aluminum 133%
A1/0-03AIAPC35UT105
A2/0-03AIAPC35UT105
A3/0-03AIAPC35UT105
A4/0-03AIAPC35UT105
A250-03AIAPC35UT105
A350-03AIAPC35UT105

Size Insulation No. of Size of Conductor Insulation Insulation


AWG Thickness Ground Ground Diameter Diameter
Shield
or
(mil)
Wires Wires
(in)
(in)
(in)
KCMIL

Overall
Jacket
(in)

Approx.
Weight
(lb/MFT)

Minimum Ampacity
Bending
90C
Radius
in Duct
(in)

Ampacity
90C
in Air

1
1/0
2/0
3/0
4/0
250
350
500
750

260
260
260
260
260
260
260
260
260

3
3
3
3
3
3
3
3
3

10
10
8
8
8
8
7
6
5

0.299
0.336
0.379
0.423
0.479
0.522
0.622
0.742
0.917

0.87
0.91
0.95
1
1.05
1.1
1.2
1.32
1.5

0.93
0.97
1.01
1.07
1.13
1.17
1.27
1.39
1.59

2.46
2.54
2.63
2.76
2.88
2.99
3.22
3.48
3.91

2461
2634
2896
3196
3489
3759
4447
5316
6783

18
18
19
20
21
21
23
25
28

145
165
185
210
240
265
315
385
475

165
185
215
245
285
315
385
475
600

1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345

3
3
3
3
3
3
3

10
8
8
8
8
7
6

0.336
0.379
0.423
0.479
0.522
0.622
0.742

1.08
1.13
1.17
1.23
1.27
1.37
1.49

1.16
1.2
1.24
1.3
1.35
1.45
1.58

2.95
3.04
3.14
3.28
3.38
3.6
3.89

3395
3680
3938
4321
4616
5297
6315

21
22
22
23
24
26
28

165
185
210
240
265
315
385

185
215
245
285
315
385
475

1/0
2/0
3/0
4/0
250
350
500

345
345
345
345
345
345
345

3
3
3
3
3
3
3

10
8
8
8
8
7
6

0.336
0.379
0.423
0.479
0.522
0.622
0.742

1.08
1.13
1.17
1.23
1.27
1.37
1.49

1.16
1.2
1.24
1.3
1.35
1.45
1.58

2.95
3.04
3.14
3.28
3.38
3.6
3.89

3395
3680
3938
4321
4616
5297
6315

21
22
22
23
24
26
28

165
185
210
240
265
315
385

185
215
245
285
315
385
475

1/0
2/0
3/0
4/0
250
350

420
420
420
420
420
420

3
3
3
3
3
3

10
8
8
8
8
7

0.336
0.379
0.423
0.479
0.522
0.622

1.23
1.28
1.32
1.38
1.42
1.52

1.31
1.35
1.39
1.45
1.5
1.61

3.29
3.39
3.48
3.6
3.71
3.96

4128
4433
4712
5059
5375
6190

24
24
25
26
26
28

165
185
210
240
265
315

185
215
245
285
315
385

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
904
20140921

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 1/C
Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90C, for emergency overload of 130C and for short circuit of 250C. The cables meet the
requirements for application in NEC Class I , Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC Articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Specifications
National Fire Protection Association (NFPA 70) National Electric Code (NEC)
UL 1569 Metal Clad Cables
UL 44 Thermoset-Insulated Wires and Cables
ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
Listed by UL as Type MC-HL per Standard UL 1569 Metal-Clad Cables.
Listed by UL as Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
Custom ground sizes
CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016 American Wire Group, Inc.

905
20160220

ARMORED CABLES

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers
make the cable round. A binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 1/C
Item #

Conductor
No. of
Strands

1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000

19
19
19
19
37
37
37
37
37
61
61
61

Conductor
Nominal
O.D.
(in)
0.34
0.38
0.42
0.48
0.52
0.57
0.62
0.66
0.74
0.81
0.91
1.12

Insulation
(mil)

Jacket
(mil)

55
55
55
55
65
65
65
65
65
80
80
80

50
50
50
50
50
50
50
50
50
60
60
60

No. x AWG
Copper
Ground
Wires
10 x 14
10 x 14
13 x 14
16 x 14
10 x 12
13 x 12
13 x 12
16 x 12
16 x 12
16 x 12
13 x 10
16 x 10

Approximate
O.D.
(in)

Ampacity**
90C

1.19
1.23
1.28
1.33
1.44
1.44
1.44
1.44
1.44
1.57
1.77
1.87

170
195
225
260
295
325
370
400
455
585
660
790

Approximate
Net
Weight
(lb/MFT)
800
900
1065
1255
1440
1660
1820
2040
2360
2735
3375
4305

ARMORED CABLES

CWCAPC-1-1/0
CWCAPC-1-2/0
CWCAPC-1-3/0
CWCAPC-1-4/0
CWCAPC-1-250
CWCAPC-1-300
CWCAPC-1-350
CWCAPC-1-400
CWCAPC-1-500
CWCAPC-1-600
CWCAPC-1-750
CWCAPC-1-1000*

Conductor
Size
(AWG/kcmil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
905
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 2/C
Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90C, for emergency overload of 130C and for short circuit of 250C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC Articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Copper Conductor
XLP Insulation
Filters
Binder Tape
Corrugated Armor
PVC Jacket

Specifications
National Fire Protection Association (NFPA 70) National Electric Code (NEC)
UL 1569 Metal Clad Cables
UL 44 Thermoset-Insulated Wires and Cables
ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
Listed by UL as Type MC-HL per Standard UL 1569 Metal-Clad Cables.
Listed by UL as Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
Custom ground sizes
CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016 American Wire Group, Inc.

906
20160220

ARMORED CABLES

Copper Ground Wire

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers
make the cable round. A binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 2/C
Item #

Conductor
No. of
Strands

8*
6*
4*
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
750

7
7
7
7
19
19
19
19
19+
37
37
37
37
37
61

Conductor
Nominal
O.D.
(in)
0.14
0.18
0.23
0.27
0.30
0.34
0.38
0.42
0.48
0.52
0.57
0.62
0.68
0.74
0.91

Insulation
(mil)

Jacket
(mil)

45
45
45
45
55
55
55
55
55
65
65
65
65
65
80

50
50
50
50
50
50
50
50
60
60
60
60
60
60
75

No. x AWG
Copper
Ground
Wires
10
6
8
6
6
6
6
4
4
4
3
3
3
2
1

Approximate
O.D.
(in)

Ampacity**
90C

0.86
0.96
1.06
1.16
1.44
1.44
1.44
1.57
1.77
1.77
1.87
2.06
2.06
2.28
2.79

55
75
95
130
150
170
195
225
260
290
320
350
380
430
535

Approximate
Net
Weight
(lb/MFT)
380
500
640
865
1110
1265
1460
1790
2155
2450
2865
3265
3615
4410
6505

ARMORED CABLES

CWCAPC-2-8*
CWCAPC-2-6*
CWCAPC-2-4*
CWCAPC-2-2
CWCAPC-2-1
CWCAPC-2-1/0
CWCAPC-2-2/0
CWCAPC-2-3/0
CWCAPC-2-4/0
CWCAPC-2-250
CWCAPC-2-300
CWCAPC-2-350
CWCAPC-2-400
CWCAPC-2-500
CWCAPC-2-750

Conductor
Size
(AWG/kcmil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
906
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 3/C
Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90C, for emergency overload of 130C and for short circuit of 250C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC Articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Copper Conductor
XLP Insulation
Filters
Binder Tape
Corrugated Armor
PVC Jacket

Specifications
National Fire Protection Association (NFPA 70) National Electric Code (NEC)
UL 1569 Metal Clad Cables
UL 44 Thermoset-Insulated Wires and Cables
ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
Listed by UL as Type MC-HL per Standard UL 1569 Metal-Clad Cables.
Listed by UL as Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
Custom ground sizes
CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
20160220

907Copyright 2016 American Wire Group, Inc.

ARMORED CABLES

Copper Ground Wire

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers
make the cable round. A binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 3/C
Item #

Conductor
No. of
Strands

8*
6*
4*
2
1
1/0
2/0
3/0
4/0
250
350
400
500
750
1000*

7
7
7
7
19
19
19
19
19
37
37
37
37
61
61

Conductor
Nominal
O.D.
(in)
0.14
0.18
0.23
0.27
0.30
0.34
0.38
0.42
0.48
0.52
0.62
0.66
0.74
0.91
1.12

Insulation
(mil)

Jacket
(mil)

45
45
45
45
55
55
55
55
55
65
65
65
65
80
80

50
50
50
50
50
50
50
50
60
60
60
60
75
75
85

No. x AWG
Copper
Ground
Wires
3 x 14
3 x 12
3 x 12
3 x 10
3 x 10
3 x 10
3 x 10
3x8
3x8
3x8
3x6
3x6
3x6
3x4
3x4

Approximate
O.D.
(in)

Ampacity**
90C

0.91
1.01
1.11
1.44
1.44
1.44
1.57
1.57
1.77
1.87
2.28
2.28
2.58
3.08
3.33

55
75
97
130
150
170
195
225
260
290
350
375
430
535
615

Approximate
Net
Weight
(lb/MFT)
465
615
810
1205
1415
1645
1965
2375
2880
3340
4520
5070
6260
9100
11965

ARMORED CABLES

CWCAPC-3-8*
CWCAPC-3-6*
CWCAPC-3-4*
CWCAPC-3-2
CWCAPC-3-1
CWCAPC-3-1/0
CWCAPC-3-2/0
CWCAPC-3-3/0
CWCAPC-3-4/0
CWCAPC-3-250
CWCAPC-3-350
CWCAPC-3-400
CWCAPC-3-500
CWCAPC-3-750
CWCAPC-3-1000*

Conductor
Size
(AWG/kcmil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
907
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 4/C
Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90C, for emergency overload of 130C and for short circuit of 250C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC Articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Copper Conductor
XLP Insulation
Filters
Binder Tape
Corrugated Armor
PVC Jacket

Specifications
National Fire Protection Association (NFPA 70) National Electric Code (NEC)
UL 1569 Metal Clad Cables
UL 44 Thermoset-Insulated Wires and Cables
ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
Listed by UL as Type MC-HL per Standard UL 1569 Metal-Clad Cables.
Listed by UL as Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
Custom ground sizes
CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016 American Wire Group, Inc.

908
20160220

ARMORED CABLES

Copper Ground Wire

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers
make the cable round. A binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 4/C
Item #

Conductor
No. of
Strands

2
1
1/0
2/0
3/0
4/0
250
1/0
2/0
3/0
4/0
250
350
400
500
750
1000*

7
19
19
19
19
19
37
19
19
19
19
37
37
37
37
61
61

Conductor
Nominal
O.D.
(in)
0.27
0.30
0.34
0.38
0.42
0.48
0.52
0.34
0.38
0.42
0.48
0.52
0.62
0.66
0.74
0.91
1.12

Insulation
(mil)

Jacket
(mil)

45
55
55
55
55
55
65
55
55
55
55
65
65
65
65
80
80

50
50
50
60
60
60
60
50
50
50
60
60
60
60
75
75
85

No. x AWG
Copper
Ground
Wires
6
6
6
6
4
4
4
3 x 10
3 x 10
3x8
3x8
3x8
3x6
3x6
3x6
3x4
3x4

Approximate
O.D.
(in)

Ampacity**
90C

1.44
1.44
1.57
1.77
1.77
1.87
2.06
1.44
1.57
1.57
1.77
1.87
2.28
2.28
2.58
3.08
3.33

104
120
136
156
180
208
232
170
195
225
260
290
350
375
430
535
615

Approximate
Net
Weight
(lb/MFT)
1440
1705
2045
2480
3000
3620
4240
1645
1965
2375
2880
3340
4520
5070
6260
9100
11965

ARMORED CABLES

CWCAPC-4-2
CWCAPC-4-1
CWCAPC-4-1/0
CWCAPC-4-2/0
CWCAPC-4-3/0
CWCAPC-4-4/0
CWCAPC-4-250
CWCAPC-3-1/0
CWCAPC-3-2/0
CWCAPC-3-3/0
CWCAPC-3-4/0
CWCAPC-3-250
CWCAPC-3-350
CWCAPC-3-400
CWCAPC-3-500
CWCAPC-3-750
CWCAPC-3-1000*

Conductor
Size
(AWG/kcmil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
908
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 5/C
Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90C, for emergency overload of 130C and for short circuit of 250C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC Articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Copper Conductor
XLP Insulation
Copper Ground Wire
Binder Tape
Corrugated Armor
PVC Jacket

Specifications
National Fire Protection Association (NFPA 70) National Electric Code (NEC)
UL 1569 Metal Clad Cables
UL 44 Thermoset-Insulated Wires and Cables
ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
Listed by UL as Type MC-HL per Standard UL 1569 Metal-Clad Cables.
Listed by UL as Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
Custom ground sizes
CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016 American Wire Group, Inc.

909
20160220

ARMORED CABLES

Filters

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers
make the cable round. A binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable


FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 5/C
Item #

Conductor
No. of
Strands

8*
6*
4*
2
1
1/0
2/0
3/0
4/0
250
300
350

7
7
7
7
19
19
19
19
19
37
37
37

Conductor
Nominal
O.D.
(in)
0.14
0.18
0.23
0.27
0.30
0.34
0.38
0.42
0.48
0.52
0.57
0.62

Insulation
(mil)

Jacket
(mil)

45
45
45
45
55
55
55
55
55
65
65
65

50
50
50
50
50
60
60
60
60
60
75
75

No. x AWG
Copper
Ground
Wires
10
8
8
6
6
6
6
4
4
4
3
3

Approximate
O.D.
(in)

Ampacity**
90C

1.06
1.14
1.44
1.44
1.57
1.77
1.77
1.87
2.06
2.28
2.58
2.58

44
60
88
104
120
136
156
180
208
232
256
280

Approximate
Net
Weight
(lb/MFT)
700
855
1235
1685
2055
2490
2960
3625
4420
5190
6245
7090

ARMORED CABLES

CWCAPC-5-8*
CWCAPC-5-6*
CWCAPC-5-4*
CWCAPC-5-2
CWCAPC-5-1
CWCAPC-5-1/0
CWCAPC-5-2/0
CWCAPC-5-3/0
CWCAPC-5-4/0
CWCAPC-5-250
CWCAPC-5-300
CWCAPC-5-350

Conductor
Size
(AWG/kcmil)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
909
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

UL Type MC Copper Conductor


with Ground PVC Jacket
600V
Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive
2002/95/EC.
Run from the combiner box to the inverter
Suitable for rooftop solar applications
Outdoors
In wet locations (Type XHHW-2 , or RHW-2 conductors)
Direct buried
Encased in concrete
Hazardous locations
Strong, but lightweight alloy armor resists damage
Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
More flexible than conduit
Factory tested engineered product that protects conductors from damage during installation
Meets or exceeds requirements of the NEC, as well as applicable UL Standards
Construction
Stranded soft drawn copper conductor. Flame retardant thermoset crosslinked polyethylene (XLPE)
insulation Type XHHW-2 conductors rated for wet or dry locations at temperatures not to exceed
90C. Grounding is one bare copper stranded conductor, except for sizes 14 AWG through 1 AWG
contain a green insulated grounding conductor. Phase and grounding conductors are cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl
chloride (PVC) compound jacket. Special constructions available upon request.

Notes
Ampacities are based on Table 310.15(B)(16) of the NEC.
* Ampacities shown are for general use as specified by the NEC, Section 310.15. For equipment
marked for use at higher temperatures, the conductor ampacity shall be limited to the following
per NEC 110.14(C):
60C when terminated to equipment for circuits rated 100 amperes or less or marked for size 14
AWG through 1 AWG conductor.
75C when terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
90C for ampacity derating purposes.
When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be reduced by a factor of 0.80 per NEC 310.15(B)(2)(a). The above data is approximate and subject to normal manufacturing tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016 American Wire Group, Inc.

910
20160220

ARMORED CABLES

Standards
Underwriters Laboratories Standards UL-44
Class B stranding, per ASTM B 801
UL-1569 for Type MC
Federal Specification A-A59544
IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
ICEA T-29-520 (210,000 Btu/hr) Flame Test, and the National Electrical Code (NEC)
Single conductors are rated XHHW-2 600V, and CT Use 1/0 AWG and larger.
Additional UL Type PV available upon request.
Aluminum armor is rated for Direct Burial, using 6 AWG and larger conductors, with overall jacket

UL Type MC Copper Conductor


with Ground PVC Jacket
600V

ARMORED CABLES

Item #

Conductor
Size
(AWG/kcmil)

No. of
Conductors

Green
Ground

14-02AIAWG
14-03AIAWG
14-04AIAWG
12-02AIAWG
12-03AIAWG
12-04AIAWG
10-02AIAWG
10-03AIAWG
10-04AIAWG
8-02AIAWG
8-03AIAWG
8-04AIAWG
6-02AIAWG
6-03AIAWG
6-04AIAWG
4-03AIAWG
4-04AIAWG
3-03AIAWG
3-04AIAWG
2-03AIAWG
2-04AIAWG
1-03AIAWG

14
14
14
12
12
12
10
10
10
8
8
8
6
6
6
4
4
3
3
2
2
1

2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
3
4
3
4
3

1-04AIAWG

1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
300
300
350
350
400
400
500
500
600
600
750
750

3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

14 AWG
14 AWG
14 AWG
12 AWG
12 AWG
12 AWG
10 AWG
10 AWG
10 AWG
10 AWG
10 AWG
10 AWG
8 AWG
8 AWG
8 AWG
8 AWG
8 AWG
6 AWG
6 AWG
6 AWG
6 AWG
6 AWG
Green Insulated
6 AWG
Green Insulated
6 AWG Bare
6 AWG Bare
6 AWG Bare
6 AWG Bare
4 AWG Bare
4 AWG Bare
4 AWG Bare
4 AWG Bare
4 AWG Bare
4 AWG Bare
3 AWG Bare
3 AWG Bare
3 AWG Bare
3 AWG Bare
3 AWG Bare
3 AWG Bare
2 AWG Bare
2 AWG Bare
2 AWG Bare
2 AWG Bare
1 AWG Bare
1 AWG Bare

1/0-03AIAWG
1/0-04AIAWG
2/0-03AIAWG
2/0-04AIAWG
3/0-03AIAWG
3/0-04AIAWG
4/0-03AIAWG
4/0-04AIAWG
250-03AIAWG
250-04AIAWG
300-03AIAWG
300-04AIAWG
350-03AIAWG
350-04AIAWG
400-03AIAWG
400-04AIAWG
500-03AIAWG
500-04AIAWG
600-03AIAWG
600-04AIAWG
750-03AIAWG
750-04AIAWG

Outside
Diameter
Over
Armor
0.464
0.498
0.536
0.503
0.542
0.584
0.553
0.597
0.646
0.677
0.757
0.834
0.791
0.884
0.974
0.964
1.070
1.049
1.164
1.103
1.228
1.195

Outside
Diameter
Over
Jacket
0.564
0.700
0.737
0.705
0.747
0.786
0.754
0.799
0.848
0.892
0.957
1.021
0.974
1.045
1.123
1.161
1.250
1.220
1.329
1.306
1.415
1.295

Jacket
Thickness

0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05

Approximate
Net
Weight
(lb/MFT)
191
219
249
227
265
304
282
335
389
427
524
618
566
700
832
900
1093
1075
1306
1234
1515
1162

Allowable
Ampacity
75C
(Amps)
15
15
15
20
20
20
30
30
30
50
50
50
65
65
65
85
85
100
100
115
115
130

Allowable
Ampacity
90C
(Amps)
15
15
15
20
20
20
30
30
30
55
55
55
75
75
75
95
95
115
115
130
130
145

1.336

1.436

0.05

1477

130

145

1.213
1.335
1.308
1.441
1.415
1.562
1.536
1.697
1.648
1.822
1.760
1.948
1.862
2.061
1.956
2.167
2.131
2.363
2.411
2.677
2.631
2.923

1.313
1.435
1.408
1.541
1.515
1.682
1.656
1.817
1.768
1.942
1.880
2.068
1.982
2.181
2.076
2.287
2.251
2.513
2.561
2.827
2.781
3.073

0.05
0.05
0.05
0.05
0.05
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.075
0.075
0.075
0.075
0.075

1359
1742
1624
2092
2048
2637
2498
3233
2904
3770
3192
4211
3931
5120
4173
5514
5451
7124
6454
8450
8015
10506

150
150
175
175
200
200
230
230
255
255
285
285
310
310
335
335
380
380
420
420
475
475

170
170
195
195
225
225
260
260
290
290
320
320
350
350
380
380
430
430
475
475
535
535

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
910
20160220

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

CONTROL CABLES
Table of Contents
Control Cable FR-XLPE Insulated Conductors, PVC Jacket 600V.......................................501
Power Cable FR-XLPE Insulated Conductors, PVC Jacket 600V .......................................502
Control Cable FR-XLPE Insulated Conductors, CPE Jacket 600V ..................................... 503
Power Cable FR-XLPE Insulated Conductors, CPE Jacket 600V.........................................504
Control Cable FR-XLPE Insulated Conductors, Copper Shield, CPE Jacket 600V ............505
Control Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V....................................506
Power Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V......................................507
Control Cable FR-XLPE Insulated Conductors, Smooth Helical Bare Copper Shield,
XLPO Jacket 600V..................................................................................................................508
Control Cable FR-XLPE Insulated Conductors, Longitudinal Corrugated Bare Copper
Shield, XLPO Jacket 600V .....................................................................................................531
Control Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................509
Power Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................510
Control Cable FR-EPR Insulated Conductors, CPE Jacket 600V .........................................511
Power Cable FR-EPR Insulated Conductors, CPE Jacket 600V...........................................512
Control Cable FR-EPR Insulated Conductors, Copper Shield, CPE Jacket 600V...............513
20/10 Control Cable, PE/PVC Insulated Conductors, PVC Jacket 600V ..............................514
20/10 Control Cable, PE/PVC Insulated Conductors, Shield, PVC Jacket 600V .................515
THHN/PVC Tray Cable (Type TC) 600V
TFN, THWN or THHN Insulated Conductors, PVC Jacket 600V .......................................517
TFN, THWN or THHN Insulated Conductors, Shielded, Drain Wire, PVC Jacket 600V ..518
THWN or THHN Insulated Conductors with Ground, PVC Jacket 600V .........................519
Aluminum Three Conductor UL Type TC 600V .....................................................................529
Aluminum Four Conductor UL Type TC 600V ......................................................................530
Thermocouple Cable, EX, JX, KX, TX 600V .........................................................................520
IMSA 20-1 & ISMA 19-1 Traffic Control Cable 600V ............................................................521
IMSA 50-2 Tube Loop Lead-In Wire 600V .............................................................................522

IMSA 51-5 Inductant Loop Detector Cable 600V .................................................................525


IMSA Selection Guide ...........................................................................................................526
IMSA Color Code Chart .........................................................................................................527
IMSA Cable Shipping Weights XHHX-2 & USE-2 ...........................................................528
Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

500
20150508

CONTROL CABLES

IMSA 51-1 THHN Loop Detector Lead-In Wire 600V ............................................................523


IMSA 51-3 Loop Detector Wire 600V ....................................................................................524

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Control Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene
insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers
where necessary to make round, cable tape, PVC jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
EPR Insulation
CPE, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

501
20140110

Control Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

CONTROL CABLES

Item #

Number Size
of
AWG
Conductors

Number of Nominal Nominal Nominal Nominal Nominal


Strands Insulation Insulation Jacket
Jacket
Cable
Thickness Thickness Thickness Thickness
O.D.
(in)
(mm)
(in)
(mm)
(in)

Nominal
Cable
O.D.
(mm)

Copper
Weight
/MFT
(lb)

Copper
Weight
/km
(kg)

Approx.
Weight
/MFT
(lb)

Approx.
Weight
/km
(kg))

14-R-PVC-2-FLAT 2 FLAT
14-R-PVC-2
2
14-R-PVC-3
3
14-R-PVC-4
4
14-R-PVC-5
5
14-R-PVC-7
7
14-R-PVC-9
9
14-R-PVC-12
12
14-R-PVC-19
19
14-R-PVC-25
25
14-R-PVC-30
30
14-R-PVC-37
37

14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.235x.370
0.365
0.390
0.425
0.465
0.590
0.620
0.680
0.800
0.985
1.050
1.130

5.97x9.40
9.270
9.910
10.800
11.810
14.990
15.750
17.270
20.320
25.020
26.670
28.700

25
25
40
53
66
93
119
159
252
323
387
490

37
37
59
79
99
138
177
237
375
481
571
729

62
73
93
116
140
176
245
302
460
641
740
888

92
109
138
173
208
262
365
449
685
954
1101
1322

12-R-PVC-2-FLAT
2 Flat
12-R-PVC-2
2
12-R-PVC-3+GRND 3+Grnd
12-R-PVC-3
3
12-R-PVC-4
4
12-R-PVC-5
5
12-R-PVC-7
7
12-R-PVC-9
9
12-R-PVC-12
12
12-R-PVC-19
19
12-R-PVC-25
25
12-R-PVC-30
30
12-R-PVC-37
37

12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.245x.400
0.410
0.435
0.435
0.475
0.515
0.595
0.695
0.780
0.930
1.095
1.150
1.240

6.2 x10.16
10.410
11.050
11.050
12.070
13.080
15.110
17.650
19.810
23.620
27.810
29.210
31.500

40
41
86
65
86
108
150
193
258
403
515
618
741

60
61
128
96
128
160
224
288
385
600
767
920
1103

86
96
143
125
157
191
260
340
429
681
885
1005
1185

128
143
213
186
234
284
387
506
638
1013
1317
1496
1764

10-R-PVC-2-FLAT
10-R-PVC-2
10-R-PVC-3+GRND
10-R-PVC-3
10-R-PVC-4
10-R-PVC-5
10-R-PVC-7
10-R-PVC-9
10-R-PVC-12

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.06
0.06
0.06
0.06
0.08

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.290x.480 7.37x12.19
0.455
11.56
0.485
12.32
0.485
12.32
0.515
13.08
0.615
15.62
0.67
17.02
0.785
19.94
0.895
22.73

66
67
135
101
135
167
234
295
402

98
100
200
150
200
249
349
440
598

114
130
201
173
236
287
371
479
644

170
193
299
257
351
427
552
713
958

2 Flat
2
3+Grnd
3
4
5
7
9
12

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
501
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Power Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V
Applications
As flame-retardant three or four conductor power cables rated 600V, 90C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.
Construction
Class B stranded uncoated copper conductor, XLPE cross-linked polyethylene insulation, surface
print phase identification. Three or four insulated conductors twisted with a Class B stranded uncoated copper grounding conductor in two opposite valleys, suitable fillers, cable tape, PVC jacket
overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables pass UL and IEEE-383 ribbon burner flame tests.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test (2 AWG and larger).
Cables UL listed for Direct Burial.
Cables UL listed for Open Wiring.
Cables meet requirements of ICEA S-95-658/NEMA WC70.
Color Code ICEA Method 4
Notes
Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30C ambient temperature.
Grounding conductor per UL Standard 1277 for Type TC Tray Cable
Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
EPR Insulation
CPE, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications..
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

502
20140110

Power Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

CONTROL CABLES

Item #

Number of Size
Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal


Strand
Wire Insulation Insulation Jacket
Jacket
Size Thickness Thickness Thickness Thickness
AWG
(in)
(mm)
(in)
(mm)
7/.0242
14
0.0300
0.76
0.05
1.14
7/.0305
12
0.0300
0.76
0.05
1.14
7/.0385
10
0.0300
0.76
0.06
1.52

Nominal Nominal
Cable
Cable
O.D.
O.D.
(in)
(mm)
0.425
10.80
0.475
12.07
0.515
13.08

Copper
Weight
/MFT
(lb)
53
86
135

Copper
Weight
/km
(kg)
79
128
200

Approx.
Weight
/MFT
(lb)
116
157
236

Approx.
Weight
/km
(kg)
173
234
351

3RXLP-14
3RXLP-12
3RXLP-10

3
3
3

14
12
10

3RXLP-8
4RXLP-8

3
4

8
8

7/.0486
7/.0486

10
10

0.045
0.045

1.14
1.14

0.06
0.06

1.52
1.52

0.640
0.705

16.26
17.91

190
242

283
360

314
385

467
573

3RXLP-6
4RXLP-6

3
4

6
6

7/.0612
7/.0612

8
8

0.045
0.045

1.14
1.14

0.06
0.06

1.52
1.52

0.720
0.790

18.29
20.07

301
384

448
571

445
558

662
830

3RXLP-4
4RXLP-4

3
4

4
4

7/.0772
7/.0772

8
8

0.045
0.045

1.14
1.14

0.08
0.08

2.03
2.03

0.875
0.950

22.23
24.13

448
578

667
862

653
820

972
1220

3RXLP-2
4RXLP-2

3
4

2
2

7/.0974
7/.0974

6
6

0.045
0.045

1.14
1.14

0.08
0.08

2.03
2.03

1.000
1.095

25.40
27.81

716
919

1066
1368

964
1214

1435
1807

3RXLP-1
4RXLP-1

3
4

1
1

19/.0664
19/.0664

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.120
1.235

28.45
31.37

872
1136

1298
1691

1199
1704

1784
2536

3RXLP-1/0
4RXLP-1/0

3
4

1/0
1/0

19/.0745
19/.0745

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.215
1.340

30.86
34.04

1081
1413

1609
2103

1414
1825

2104
2716

3RXLP-2/0
4RXLP-2/0

3
4

2/0
2/0

19/.0837
19/.0837

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.310
1.450

33.27
36.83

1341
1760

1996
2619

1706
2223

2539
3308

3RXLP-3/0
4RXLP-3/0

3
4

3/0
3/0

19/.0940
19/.0940

4
4

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.420
1.570

36.07
39.88

1717
2245

2555
3341

2437
3123

3627
4648

3RXLP-4/0
4RXLP-4/0

3
4

4/0
4/0

19/.1055
19/.1055

4
4

0.055
0.055

1.40
1.40

0.08
0.11

2.03
2.79

1.540
1.765

39.12
44.83

2132
2796

3173
4161

2600
3444

3869
5125

3RXLP-250
4RXLP-250

3
4

250
250

37/.0822
37/.0822

4
4

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

1.750
1.930

44.45
49.02

2494
3282

3712
4884

3142
4048

4676
6024

3RXLP-350
4RXLP-350

3
4

350
350

37/.0973
37/.0973

3
3

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

1.970
2.180

50.04
55.37

3474
4577

5170
6811

4230
5470

6295
8140

3RXLP-500
4RXLP-500

3
4

500
500

37/.1162
37/.1162

2
2

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

2.250
2.475

57.15
62.87

4938
6509

7349
9687

5829
7579

8675
11279

3RXLP-750
4RXLP-750

3
4

750
750

61/.1109
61/.1109

1
1

0.080
0.080

2.03
2.03

0.14
0.14

3.56
3.56

2.810
3.115

71.37
79.12

7278
9712

10831
14453

9101
11746

13544
17480

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
502
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene
insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers
where necessary to make round, cable tape, CPE jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Color Code ICEA Method 4.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
EPR Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
CONTROL CABLES

Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

503
20140110

Control Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Size
AWG

Number of Nominal Nominal Nominal Nominal Nominal


Strands Insulation Insulation Jacket
Jacket
Cable
Thickness Thickness Thickness Thickness
O.D.
(in)
(mm)
(in)
(mm)
(in)

Nominal
Cable
O.D.
(mm)

Copper
Weight
/MFT
(lb)

Copper
Weight
/km
(kg)

Approx.
Weight
/MFT
(lb)

Approx.
Weight
/km
(kg)

14-R-CPE-2-FLAT 2 FLAT
14-R-CPE-2
2
14-R-CPE-3
3
14-R-CPE-4
4
14-R-CPE-5
5
14-R-CPE-7
7
14-R-CPE-9
9
14-R-CPE-12
12
14-R-CPE-19
19
14-R-CPE-25
25
14-R-CPE-30
30
14-R-CPE-37
37

14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.235x.370
0.365
0.390
0.425
0.465
0.590
0.620
0.680
0.800
0.985
1.050
1.130

5.97x9.40
9.270
9.910
10.800
11.810
14.990
15.750
17.270
20.320
25.020
26.670
28.700

25
25
40
53
66
93
119
159
252
323
387
490

37
37
59
79
99
138
177
237
375
481
571
729

62
73
93
116
140
176
245
302
460
641
740
888

92
109
138
173
208
262
365
449
685
954
1101
1322

12-R-CPE-2-FLAT 2 FLAT
12-R-CPE-2
2
12-R-CPE-3+GRND 3+Grnd
12-R-CPE-3
3
12-R-CPE-4
4
12-R-CPE-5
5
12-R-CPE-7
7
12-R-CPE-9
9
12-R-CPE-12
12
12-R-CPE-19
19
12-R-CPE-25
25
12-R-CPE-30
30
12-R-CPE-37
37

12
12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.245x.400 6.22x10.16
0.410
10.410
0.435
11.050
0.435
11.050
0.475
12.070
0.515
13.080
0.595
15.110
0.695
17.650
0.780
19.810
0.930
23.620
1.095
27.810
1.150
29.210
1.240
31.500

40
41
86
65
86
108
150
193
258
403
515
618
741

60
61
128
96
128
160
224
288
385
600
767
920
1103

86
96
143
125
157
191
260
340
429
681
885
1005
1185

128
143
213
186
234
284
387
506
638
1013
1317
1496
1764

10-R-CPE-2-FLAT 2 FLAT
10-R-CPE-2
2
10-R-CPE-3+GRND 3+Grnd
10-R-CPE-3
3
10-R-CPE-4
4
10-R-CPE-5
5
10-R-CPE-7
7
10-R-CPE-9
9
10-R-CPE-12
12

10
10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.290x.480
0.455
0.485
0.485
0.515
0.615
0.670
0.785
0.895

66
67
135
101
135
167
234
295
402

98
100
200
150
200
249
349
440
598

114
130
201
173
236
287
371
479
644

170
193
299
257
351
427
552
713
958

7.37x12.19
11.560
12.320
12.320
13.080
15.620
17.020
19.940
22.730

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
503
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Power Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V
Applications
As flame-retardant three or four conductor power cables rated 600V, 90C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.
Construction
Class B stranded uncoated copper conductor, FR-XLPE flame-retardant cross-linked polyethylene insulation, surface print phase identification. Three or four insulated conductors twisted with a Class B
stranded uncoated copper grounding conductor and suitable fillers, cable tape, CPE jacket overall,
surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Individual conductors UL listed as Type XHHW-2.
Individual conductors pass UL VW-1 flame test.
Overall jacket UL listed as Sunlight Resistant and Oil Resistant II.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables UL listed for Direct Burial.
Cables UL listed for Open Wiring.
Cables meet requirements of ICEA S-95-658/NEMA WC70.
Color Code ICEA Method 4.
Notes
Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30C ambient temperature.
Grounding conductor per UL Standard 1277 for Type TC Tray Cable.
Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
EPR Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield, Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

504
20140110

Power Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Size
Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal


Strand
Wire Insulation Insulation Jacket
Jacket
Size Thickness Thickness Thickness Thickness
AWG
(in)
(mm)
(in)
(mm)
7/.0242
14
0.0300
0.76
0.05
1.14
7/.0305
12
0.0300
0.76
0.05
1.14
7/.0385
10
0.0300
0.76
0.06
1.52

Nominal Nominal
Cable
Cable
O.D.
O.D.
(in)
(mm)
0.425
10.80
0.475
12.07
0.515
13.08

Copper
Weight
/MFT
(lb)
53
86
135

Copper
Weight
/km
(kg)
79
128
200

Approx.
Weight
/MFT
(lb)
116
157
236

Approx.
Weight
/km
(kg)
173
234
351

3EXLP-14
3EXLP-12
3EXLP-10

3
3
3

14
12
10

3EXLP-8
4EXLP-8

3
4

8
8

7/.0486
7/.0486

10
10

0.045
0.045

1.14
1.14

0.06
0.06

1.52
1.52

0.640
0.705

16.26
17.91

190
242

283
360

314
385

467
573

3EXLP-6
4EXLP-6

3
4

6
6

7/.0612
7/.0612

8
8

0.045
0.045

1.14
1.14

0.06
0.06

1.52
1.52

0.720
0.790

18.29
20.07

301
384

448
571

445
558

662
830

3EXLP-4
4EXLP-4

3
4

4
4

7/.0772
7/.0772

8
8

0.045
0.045

1.14
1.14

0.08
0.08

2.03
2.03

0.875
0.950

22.23
24.13

448
578

667
862

653
820

972
1220

3EXLP-2
4EXLP-2

3
4

2
2

7/.0974
7/.0974

6
6

0.045
0.045

1.14
1.14

0.08
0.08

2.03
2.03

1.000
1.095

25.40
27.81

716
919

1066
1368

964
1214

1435
1807

3EXLP-1
4EXLP-1

3
4

1
1

19/.0664
19/.0664

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.120
1.235

28.45
31.37

872
1136

1298
1691

1199
1704

1784
2536

3EXLP-1/0
4EXLP-1/0

3
4

1/0
1/0

19/.0745
19/.0745

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.215
1.340

30.86
34.04

1081
1413

1609
2103

1414
1825

2104
2716

3EXLP-2/0
4EXLP-2/0

3
4

2/0
2/0

19/.0837
19/.0837

6
6

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.310
1.450

33.27
36.83

1341
1760

1996
2619

1706
2223

2539
3308

3EXLP-3/0
4EXLP-3/0

3
4

3/0
3/0

19/.0940
19/.0940

4
4

0.055
0.055

1.40
1.40

0.08
0.08

2.03
2.03

1.420
1.570

36.07
39.88

1717
2245

2555
3341

2437
3123

3627
4648

3EXLP-4/0
4EXLP-4/0

3
4

4/0
4/0

19/.1055
19/.1055

4
4

0.055
0.055

1.40
1.40

0.08
0.11

2.03
2.79

1.540
1.765

39.12
44.83

2132
2796

3173
4161

2600
3444

3869
5125

3EXLP-250
4EXLP-250

3
4

250
250

37/.0822
37/.0822

4
4

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

1.750
1.930

44.45
49.02

2494
3282

3712
4884

3142
4048

4676
6024

3EXLP-350
4EXLP-350

3
4

350
350

37/.0973
37/.0973

3
3

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

1.970
2.180

50.04
55.37

3474
4577

5170
6811

4230
5470

6295
8140

3EXLP-500
4EXLP-500

3
4

500
500

37/.1162
37/.1162

2
2

0.065
0.065

1.65
1.65

0.11
0.11

2.79
2.79

2.250
2.475

57.15
62.87

4938
6509

7349
9687

5829
7579

8675
11279

3EXLP-750
4EXLP-750

3
4

750
750

61/.1109
61/.1109

1
1

0.080
0.080

2.03
2.03

0.14
0.14

3.56
3.56

2.810
3.115

71.37
79.12

7278
9712

10831
14453

9101
11746

13544
17480

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
504
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1
color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket
overall, surface printed.
Standards
TC Type Tray Cable per Article 340 of the NEC.
Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
Individual conductors approved as Type XHHW.
. Cables Pass IEEE-383 ribbon burner flame test.
Overall jacket approved as Sunlight Resistant.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
EPR Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

505
20140110

Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Conductor
Stranding

Conductor
Size
AWG

Overall
mils

Overall
Diameter
(in)

Approx.
Cable
Weight
/MFT
(lb)

14-402SH
14-403SH
14-404SH
14-405SH
14-406SH
14-407SH
14-408SH
14-409SH
14-412SH
14-414SH
14-415SH
14-416SH
14-418SH
14-419SH
14-420SH
14-425SH
14-427SH
14-429SH
14-431SH
14-432SH
14-437SH

2
3
4
5
6
7
8
9
12
14
15
16
18
19
20
25
27
29
31
32
37

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

45
45
45
45
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80

0.40
0.42
0.45
0.49
0.53
0.60
0.70
N/A
0.89
0.96
1.04
1.05
1.07
1.09
1.10
1.22
1.25
1.26
1.31
1.34
1.39

120
145
180
230
275
275
305
N/A
435
530
565
575
665
665
720
905
905
960
1090
1090
1165

12-452SH
12-453SH
12-454SH
12-455SH
12-456SH
12-457SH
12-458SH
12-462SH
12-464SH
12-465SH
12-466SH
12-468SH
12-469SH
12-470SH
12-475SH
12-477SH
12-479SH
12-481SH
12-482SH
12-487SH

2
3
4
5
6
7
8
12
14
15
16
18
19
20
25
27
29
31
32
37

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80

0.49
0.54
0.62
0.67
0.70
0.73
0.86
0.95
1.04
1.20
1.22
1.25
1.25
1.31
1.39
1.41
1.42
1.44
1.47
1.53

155
185
245
295
340
340
395
610
690
770
780
865
865
940
1175
1200
1270
1425
1425
1545

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
505
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V
Item #

Number of
Conductors

Conductor
Stranding

Conductor
Size
AWG

Overall
mils

Overall
Diameter
(in)

Approx.
Cable
Weight
/MFT
(lb)

10-502SH

10

45

0.52

190

10-503SH
10-504SH
10-505SH
10-506SH
10-507SH
10-508SH
10-512SH
10-514SH
10-515SH
10-516SH
10-518SH
10-519SH
10-520SH
10-525SH
10-527SH
10-529SH
10-531SH
10-532SH
10-537SH

3
4
5
6
7
8
12
14
15
16
18
19
20
25
27
29
31
32
37

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80
80

0.62
0.68
0.73
0.80
0.85
1.05
1.10
1.14
1.20
1.24
1.27
1.27
1.34
1.48
1.52
1.54
1.60
1.63
1.70

255
320
370
440
450
755
810
920
995
1020
1140
1155
1255
1600
1625
1730
1950
1950
2120

*Part numbers are for CPE jacketed cables only

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

505
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Control Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, FR-XLPE flame-retardant cross-linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where
necessary to make round, cable tape, XLPO jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
EPR Insulation
PVC,CPE CSPE Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

506
20140110

Control Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Insulation
Thickness
(in)
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

Nominal
Jacket
Thickness
(in)
.045
.045
.045
.045
.045
.060
.060
.060
.060
.080
.080
.080

Nominal
Jacket
Thickness
(mm)
1.1
1.1
1.1
1.1
1.1
1.5
1.5
1.5
1.5
2.0
2.0
2.0

14-R-XLPO-2
14-R-XLPO-3
14-R-XLPO-4
14-R-XLPO-5
14-R-XLPO-7
14-R-XLPO-9
14-R-XLPO-12
14-R-XLPO-16
14-R-XLPO-19
14-R-XLPO-26
14-R-XLPO-30
14-R-XLPO-37

2
3
4
5
7
9
12
16
19
26
30
37

14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7

12-R-XLPO-2
12-R-XLPO-3
12-R-XLPO-4
12-R-XLPO-5
12-R-XLPO-7
12-R-XLPO-9
12-R-XLPO-12
12-R-XLPO-16
12-R-XLPO-19
12-R-XLPO-26
12-R-XLPO-30
12-R-XLPO-37

2
3
4
5
7
9
12
16
19
26
30
37

12
12
12
12
12
12
12
12
12
12
12
12

10-R-XLPO-2
10-R-XLPO-3
10-R-XLPO-4
10-R-XLPO-5
10-R-XLPO-7
10-R-XLPO-9
10-R-XLPO-12

2
3
4
5
7
9
12

10
10
10
10
10
10
10

Nominal
Nominal Approximate Approximate
Cable
Cable
Cable Weight Cable Weight
O.D.
O.D.
/MFT
/Km
(in)
(mm)
(lb)
(kg)
.235 x .375 5.97 x 9.53
67
99
0.400
10.2
102
151
0.435
11.0
126
186
0.475
12.1
150
222
0.520
13.2
191
283
0.650
16.5
274
406
0.710
18.0
340
503
0.790
20.1
433
641
0.835
21.2
496
734
1.040
26.4
685
1014
1.075
27.3
762
1128
1.155
29.3
915
1406

7
7
7
7
7
7
7
7
7
7
7
7

.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

.045
.045
.045
.045
.060
.060
.060
.080
.080
.080
.080
.080

1.1
1.1
1.1
1.1
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

.255 x .415 6.48 x 11.4


0.440
11.2
0.485
12.3
0.530
13.5
0.610
15.5
0.715
18.2
0.795
20.2
0.930
23.6
0.975
24.8
1.160
29.5
1.200
30.5
1.300
33.0

92
131
164
202
283
357
462
620
710
950
1065
1285

136
194
243
299
419
528
684
918
1051
1406
1576
1902

7
7
7
7
7
7
7

.030
.030
.030
.030
.030
.030
.030

.045
.045
.060
.060
.060
.060
.080

1.1
1.1
1.5
1.5
1.5
1.5
2.0

.280 x .465
0.500
0.575
0.630
0.690
0.805
0.935

121
185
257
308
397
496
661

179
274
380
456
588
734
978

7.11 x 11.8
12.7
14.6
16.0
17.5
20.4
23.7

Part numbers are for XLPE/XLPO jacketed cables only.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
506
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Power Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V
Applications
Flame retardant control/power cable in free air, raceway and direct burial, for use in wet or dry locations. Rated at 90C wet or dry. Permitted for Exposed Run use in accordance with NEC for 3 or
more conductors . Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC.
Sunlight-and weather-resistant. Meets cold bend test at -40C.
Construction
8 AWG thru 750 kcmil annealed stranded copper conductors per ASTM B33. Class B uncoated copper grounding conductor per ASTM B8. Flame-retardant FR-XLPE insulation, XLPO jacket, colorcoded per ICEA Method 1; Table E-1. Sizes 8 AWG and larger are color-coded per ICEA Method 4;
Individual conductors colored black with conductor number surface printed in contrasting ink
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL 1581 VW-1 flame test.
Individual conductors UL44 listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-95-658, NEMA WC70.
Cables meet requirements of ICEA T-29-520 AND CSA FT-4
Color Code ICEA Method 4
Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
FRXLP or EPR Insulations
PVC, CPE, CSPE, Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

507
20140110

Power Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Insulation
Thickness
(in)

7
7
7
7

Ground
Wire
Size
AWG
10
-

.045
.045
.045
.045

Nominal
Jacket
Thickness
(in)
.060
.060
.060
.060

Nominal
Jacket
Thickness
(mm)
1.5
1.5
1.5
1.5

Nominal
Cable
O.D.
(in)
0.625
0.665
0.665
0.730

Nominal
Cable
O.D.
(mm)
15.9
16.9
16.9
18.5

Approx.
Cable Wt.
/MFT
(lb)
199
296
321
383

Approx.
Cable Wt.
/Km
(kg)
295
438
475
567

08-XLPO-2
08-XLPO-3
08-XLPO-3G
08-XLPO-4

2
3
3+GRD
4

8
8
8
8

06-XLPO-2
06-XLPO-3
06-XLPO-3G
06-XLPO-4

2
3
3+GRD
4

6
6
6
6

7
7
7
7

8
-

.045
.045
.045
.045

.060
.060
.060
.060

1.5
1.5
1.5
1.5

0.705
0.750
0.750
0.825

17.9
19.1
19.1
21.0

306
413
459
528

453
611
679
781

04-XLPO-2
04-XLPO-3
04-XLPO-3G
04-XLPO-4

2
3
3+GRD
4

4
4
4
4

7
7
7
7

8
-

.045
.045
.045
.045

.060
.060
.060
.080

1.5
1.5
1.5
2.0

0.805
0.860
0.860
0.990

20.4
21.8
21.8
25.1

437
597
643
803

647
884
952
1188

02-XLPO-2
02-XLPO-3
02-XLPO-3G
02-XLPO-4

2
3
3+GRD
4

2
2
2
2

7
7
7
7

6
-

.045
.045
.045
.045

.080
.080
.080
.080

2.0
2.0
2.0
2.0

0.975
1.035
1.035
1.140

24.8
26.3
26.3
29.0

672
915
991
1175

1001
1352
1467
1739

10-XLPO-3
10-XLPO-3G
10-XLPO-4

3
3+GRD
4

1/0
1/0
1/0

19
19
19

6
-

.055
.055
.055

.080
.080
.080

2.0
2.0
2.0

1.240
1.240
1.370

31.5
31.5
34.5

1399
1471
1794

2084
2192
2673

20-XLPO-3
20-XLPO-3G
20-XLPO-4

3
3+GRD
4

2/0
2/0
2/0

19
19
19

6
-

.055
.055
.055

.080
.080
.080

2.0
2.0
2.0

1.340
1.340
1.480

34.0
34.0
37.6

1707
1778
2203

2543
2649
3282

40-XLPO-3
40-XLPO-3G
40-XLPO-4

3
3+GRD
4

4/0
4/0
4/0

19
19
19

4
-

.055
.055
.055

.080
.080
.110

2.0
2.0
2.8

1.580
1.580
1.810

40.1
40.1
46.0

2578
2734
3455

3841
4046
5113

350-XLPO-3
350-XLPO-3G
350-XLPO-4

3
3+GRD
4

350
350
350

37
37
37

3
-

.065
.065
.065

.110
.110
.110

2.8
2.8
2.8

2.030
2.030
2.240

51.6
51.6
56.9

4251
4385
5505

6291
6490
8147

500-XLPO-3
3
500-XLPO-3G 3+GRD
500-XLPO-4
4

500
500
500

37
37
37

2
-

.065
.065
.065

.110
.110
.110

2.8
2.8
2.8

2.320
2.320
2.740

58.9
58.9
69.6

5869
6092
7668

8686
9016
11349

750-XLPO-3
750-XLPO-3G

750
750

61
61

.080
.080

.140
.140

3.6
3.6

2.860
2.860

72.6
72.6

8730
8976

12920
13284

3
3+GRD

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
507
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors


Smooth Helical Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1
color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, XLPO
jacket overall, surface printed.
Standards
TC Type Tray Cable per Article 340 of the NEC.
Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
Individual conductors approved as Type XHHW.
Cables Pass IEEE-383 ribbon burner flame test.
Overall jacket approved as Sunlight Resistant.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
EPR Insulation
PVC, CPE, CSPE Jackets
Insulated ground wires or bare ground wires
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

508
20150508

Control Cable FR-XLPE Insulated Conductors


Smooth Helical Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V
Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Copper
Shield
Thickness
(in)

Copper
Shield
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approx.
Cable
Weight
/MFT
(lb)

Approx.
Cable
Weight
/Km
(kg)

14-402SHX
14-403SHX
14-404SHX
14-405SHX
14-407SHX
14-409SHX
14-412SHX

2
3
4
5
7
9
12

14
14
14
14
14
14
14

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.045
.045
.060
.060
.060
.060

1.1
1.1
1.1
1.5
1.5
1.5
1.5

0.445
0.470
0.505
0.580
0.620
0.705
0.785

11.3
11.9
12.8
14.7
15.7
17.9
19.9

109
132
155
207
246
311
393

162
196
231
308
366
463
585

12-452SHX
12-453SHX
12-454SHX
12-455SHX
12-457SHX
12-459SHX
12-462SHX

2
3
4
5
7
9
12

12
12
12
12
12
12
12

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.045
.060
.060
.060
.060
.080

1.1
1.1
1.5
1.5
1.5
1.5
2.0

0.485
0.510
0.585
0.630
0.675
0.775
0.905

12.3
13.0
14.9
16.0
17.1
19.7
23.0

137
163
225
259
322
409
552

204
243
335
385
479
609
821

10-502SHX
10-503SHX
10-504SHX
10-505SHX
10-507SHX
10-509SHX
10-512SHX

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.060
.060
.060
.060
.080
.080

1.1
1.5
1.5
1.5
1.5
2.0
2.0

0.535
0.595
0.640
0.695
0.750
0.910
1.010

13.6
15.1
16.3
17.7
19.1
23.1
25.7

179
234
289
340
442
590
748

266
348
430
506
658
878
1113

CONTROL CABLES

*Part numbers are for XLPO jacketed cables only.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
508
20150508

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors


Longitudinal Corrugated Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts
or conduits, in tray or trough, and are suitable for direct burial.
Specifications
Conductors conform to ASTM B-3 & B-8.
Insulation conforms to UL Standard 44.
TC Type Tray Cable per Article 340 of the NEC.
Cables designed to pass the IEEE-383 & IEEE-1202 tests.
Jacket suitable for Sunlight Resistant applications.
Cables meet requirements of ICEA S-73-532 and ICEA S-95-658/NEMA WC70.
Construction
Stranded copper conductors, XLP insulated, Method 1 - Table E1 or E2 color coded or Method 4
phase-identified, conductors twisted with suitable fillers, Longitudinal Corrugated Bare Copper Tape
Shield, LSZH jacket overall, surface printed.
Options
Also available with -G Ground Wire, -SH Mylar Aluminum Foil Shield, No Shield
Notes
Dimensional data not binding, we reserve the right to alter specifications without notice. SHIPPING
TOLERANCE +/- 10%

Item #

O.A.
(mil)

O.D.
(mil)

Weight
/MFT
(lb)

2
3
4
5
7
9
12
15
19
25
31
37

45
45
45
45
45
45
45
60
60
60
80
80

0.3
0.3
0.4
0.4
0.5
0.5
0.6
0.6
0.8
0.9
0.9
1

58
75
93
114
135
172
202
229
262
323
377
448

16-02XLOHS
16-03XLOHS
16-04XLOHS
16-05XLOHS
16-07XLOHS
16-09XLOHS
16-12XLOHS
16-15XLOHS
16-19XLOHS
16-25XLOHS
16-31XLOHS
16-37XLOHS

16
16
16
16
16
16
16
16
16
16
16
16

2
3
4
5
7
9
12
15
19
25
31
37

45
45
45
60
60
60
60
80
80
80
80
80

0.4
0.4
0.4
0.4
0.5
0.6
0.6
0.7
0.7
0.8
0.9
1

69
84
104
119
140
181
246
302
352
469
590
675

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

531
20150508

CONTROL CABLES

Number
of
Conductors

18-02XLOHS
18-03XLOHS
18-04XLOHS
18-05XLOHS
18-07XLOHS
18-09XLOHS
18-12XLOHS
18-15XLOHS
18-19XLOHS
18-25XLOHS
18-31XLOHS
18-37XLOHS

Cond.
Size
AWG or
or kcmil
18
18
18
18
18
18
18
18
18
18
18
18

Control Cable FR-XLPE Insulated Conductors


Longitudinal Corrugated Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V

CONTROL CABLES

Item #

Cond.
Size
AWG or
or kcmil

Number
of
Conductors

O.A.
(mil)

O.D.
(mil)

Weight
/MFT
(lb)

14-02XLOHS
14-03XLOHS
14-04XLOHS
14-05XLOHS
14-07XLOHS
14-09XLOHS
14-12XLOHS
14-15XLOHS
14-19XLOHS
14-25XLOHS
14-31XLOHS
14-37XLOHS

14
14
14
14
14
14
14
14
14
14
14
14

2
3
4
5
7
9
12
15
19
25
31
37

45
45
45
45
45
60
60
60
60
80
80
80

0.4
0.4
0.5
0.5
0.5
0.7
0.7
0.8
0.8
1
1.1
1.2

88
109
134
155
210
296
353
450
529
740
881
1015

12-02XLOHS
12-03XLOHS
12-04XLOHS
12-05XLOHS
12-07XLOHS
12-09XLOHS
12-12XLOHS
12-15XLOHS
12-19XLOHS
12-25XLOHS
12-31XLOHS
12-37XLOHS

12
12
12
12
12
12
12
12
12
12
12
12

2
3
4
5
7
9
12
15
19
25
31
37

45
45
45
45
60
60
60
80
80
80
80
80

0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3

119
144
180
235
295
387
498
653
759
1021
1217
1413

10-02XLOHS
10-03XLOHS
10-04XLOHS
10-05XLOHS
10-07XLOHS
10-09XLOHS
10-12XLOHS
10-15XLOHS
10-19XLOHS
10-25XLOHS
10-31XLOHS
10-37XLOHS

10
10
10
10
10
10
10
10
10
10
10
10

2
3
4
5
7
9
12
15
19
25
31
37

45
45
60
60
60
60
80
80
80
80
80
80

0.5
0.5
0.6
0.7
0.7
0.8
1
1.1
1.1
1.3
1.4
1.5

169
205
275
331
422
537
738
904
1080
1431
1724
2005

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
531
20150508

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-EPR Insulated Conductors
PVC Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FREPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable
fillers where necessary to make round, cable tape, PVC jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
FRXLP Insulation
CPE, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

509
20140110

Control Cable
FR-EPR Insulated Conductors
PVC Jacket, 600V
Item #

Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal


AWG Strand
Wire Insulation Insulation Jacket
Jacket
Cable
Cable
Size
Thickness Thickness Thickness Thickness
O.D.
O.D.
AWG
(in)
(mm)
(in)
(mm)
(in)
(mm)
14-E-PVC-2-FLAT 2 FLAT 14
7/.0242
0.030
0.76
0.045
1.14
.365x.230 9.30x5.80

CONTROL CABLES

14-E-PVC-3
14-E-PVC-4
14-E-PVC-5
14-E-PVC-7
14-E-PVC-9
14-E-PVC-12
14-E-PVC-19
14-E-PVC-25
14-E-PVC-30
14-E-PVC-37

3
4
5
7
9
12
19
25
30
37

0.390
0.425
0.465
0.505
0.620
0.700
0.815
0.935
1.030
1.110

9.910
10.800
11.810
12.830
15.750
17.780
20.700
23.750
26.160
28.190

Copper
Weight
/MFT
(lb)
26

Copper
Weight
/km
(kg)
38

Approx.
Weight
/MFT
(lb)
61

Approx.
Weight
/km
(kg)
91

39
53
66
92
118
158
250
323
387
466

59
78
98
137
176
235
372
481
576
694

92
115
139
173
240
301
468
624
747
875

137
171
207
257
357
448
696
929
1112
1302

14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

12-E-PVC-2-FLAT 2 FLAT
12-E-PVC-2
2
12-E-PVC-3
3
12-E-PVC-4
4
12-E-PVC-5
5
12-E-PVC-7
7
12-E-PVC-9
9
12-E-PVC-12
12
12-E-PVC-19
19
12-E-PVC-25
25
12-E-PVC-30
30
12-E-PVC-37
37

12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.400x.245 10.20x6.20
0.410
10.410
0.435
11.050
0.475
12.070
0.520
13.210
0.595
15.110
0.695
17.650
0.765
19.430
0.940
23.880
1.095
27.810
1.150
29.210
1.240
31.500

42
42
64
85
106
149
191
247
391
515
618
762

63
63
95
127
158
221
285
368
582
767
920
1134

82
94
124
157
191
268
337
428
688
854
1002
1240

122
140
185
234
284
399
502
637
1024
1271
1491
1845

10-E-PVC-2-FLAT 2 FLAT
10-E-PVC-2
2
10-E-PVC-3
3
10-E-PVC-4
4
10-E-PVC-5
5
10-E-PVC-7
7
10-E-PVC-9
9
10-E-PVC-12
12

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.445x.270
0.455
0.485
0.560
0.615
0.670
0.760
0.950

64
65
100
134
167
234
295
402

95
97
150
199
249
349
440
598

113
128
172
234
284
381
464
651

168
190
256
348
423
567
691
969

11.30x6.90
11.560
12.320
14.220
15.620
17.020
19.300
22.990

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
509
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Power Cable
EPR Insulated Conductors
PVC Jacket, 600V
Applications
As flame-retardant three or four conductor power cables rated 600V, 90C. in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.
Construction
Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink with a Class B
stranded uninsulated tinned annealed copper grounding conductor and PVC jacket overall, surface
printed.
Standards
UL 44 Type XHHW-2
UL 1277 Type TC-ER, UL File # E57179
UL 1581
ICEA S-95-658/NEMA WC70
UL 1581 VW-1
UL 1277
IEEE 383
IEEE 1202
CSA FT4
ICEA T-29-520
Color Coding ICEA Method 4
Notes
Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30C ambient temperature.
Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

CONTROL CABLES

Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
FRXLP Insulation
CPE, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

510
20140110

Power Cable
EPR Insulated Conductors
PVC Jacket, 600V

CONTROL CABLES

Item #

Number of Size
Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal


Strand
Wire Insulation Insulation Jacket
Jacket
Size Thickness Thickness Thickness Thickness
AWG
(in)
(mm)
(in)
(mm)
7/.0242
14
0.030
0.76
0.045
1.14
7/.0305
12
0.030
0.76
0.045
1.14
7/.0385
10
0.030
0.76
0.060
1.52

Nominal Nominal
Cable
Cable
O.D.
O.D.
(in)
(mm)
0.430
10.92
0.480
12.19
0.565
14.35

Copper
Weight
/MFT
(lb)
55
87
136

Copper
Weight
/km
(kg)
82
129
202

Approx.
Weight
/MFT
(lb)
118
160
237

Approx.
Weight
/Km
(kg)
176
238
353

3REPR-14
3REPR-12
3REPR-10

3
3
3

14
12
10

3REPR-8
4REPR-8

3
4

8
8

7/.0486
7/.0486

10
10

0.045
0.045

1.14
1.14

0.060
0.060

1.52
1.52

0.655
0.720

16.64
18.29

190
242

283
360

314
393

467
585

3REPR-6
4REPR-6

3
4

6
6

7/.0612
7/.0612

8
8

0.045
0.045

1.14
1.14

0.00
0.060

1.52
1.52

0.740
0.790

18.80
20.07

297
384

442
571

456
561

679
835

3REPR-4
4REPR-4

3
4

4
4

7/.0772
7/.0772

8
8

0.045
0.045

1.14
1.14

0.080
0.080

2.03
2.03

0.880
0.950

22.35
24.13

442
578

658
861

642
822

955
1223

3REPR-2
4REPR-2

3
4

2
2

7/.0974
7/.0974

6
6

0.045
0.045

1.14
1.14

0.080
0.080

2.03
2.03

1.010
1.090

25.65
27.69

703
919

1046
1368

979
1235

1457
1838

3REPR-1
4REPR-1

3
4

1
1

19/.0664
19/.0664

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.120
1.235

28.45
31.37

872
1136

1298
1691

1021
1521

1594
2264

3REPR-1/0
4REPR-1/0

3
4

1/0
1/0

19/.0745
19/.0745

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.225
1.330

31.12
33.78

1069
1413

1591
2103

1439
1820

2142
2709

3REPR-2/0
4REPR-2/0

3
4

2/0
2/0

19/.0837
19/.0837

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.300
1.440

33.02
36.58

1340
1760

1994
2619

1720
2208

2560
3286

3REPR-3/0
4REPR-3/0

3
4

3/0
3/0

19/.0940
19/.0940

4
4

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.420
1.570

36.07
39.88

1717
2245

2555
3341

2176
2788

3238
3405

3REPR-4/0
4REPR-4/0

3
4

4/0
4/0

19/.1055
19/.1055

4
4

0.055
0.055

1.40
1.40

0.080
0.110

2.03
2.79

1.540
1.790

39.12
45.47

2130
2796

3170
4161

2614
3495

3890
5201

3REPR-250
4REPR-250

3
4

250
250

37/.0822
37/.0822

4
4

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

1.760
1.915

44.70
48.64

2494
3282

3712
4884

3184
4019

4738
5981

3REPR-350
4REPR-350

3
4

350
350

37/.0973
37/.0973

3
3

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

1.960
2.165

49.78
54.99

3474
4577

5170
6811

4187
5436

6231
8090

3REPR-500
4REPR-500

3
4

500
500

37/.1162
37/.1162

2
2

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

2.245
2.475

57.02
62.87

4934
6509

7343
9687

5847
7607

8702
11321

3REPR-750
4REPR-750

3
4

750
750

61/.1109
61/.1109

1
1

0.080
0.080

2.03
2.03

0.140
0.140

3.56
3.56

2.810
3.115

71.37
79.12

7278
9712

10831
14453

9145
11805

13610
17569

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
510
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-EPR Insulated Conductors
CPE Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FREPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable
fillers where necessary to make round, cable tape, CPE jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding ICEAA Method 1, Table E-1
FRXLP Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

511
20140110

Control Cable
FR-EPR Insulated Conductors
CPE Jacket, 600V

CONTROL CABLES

Item #

Size Conductor Ground Nominal Nominal Nominal Nominal Nominal


AWG Strand
Wire Insulation Insulation Jacket
Jacket
Cable
Size
Thickness Thickness Thickness Thickness
O.D.
AWG
(in)
(mm)
(in)
(mm)
(in)

Nominal
Cable
O.D.
(mm)

Copper
Weight
/MFT
(lb)

Copper
Weight
/km
(kg)

Approx.
Weight
/MFT
(lb)

Approx.
Weight
/km
(kg)

14-E-CPE-2-FLAT 2 FLAT
14-E-CPE-3
3
14-E-CPE-4
4
14-E-CPE-5
5
14-E-CPE-7
7
14-E-CPE-9
9
14-E-CPE-12
12
14-E-CPE-19
19
14-E-CPE-25
25
14-E-CPE-30
30
14-E-CPE-37
37

14
14
14
14
14
14
14
14
14
14
14

7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242
7/.0242

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03

.365x.230
0.390
0.425
0.465
0.505
0.620
0.700
0.815
0.935
1.030
1.110

9.30x5.80
9.910
10.800
11.810
12.830
15.750
17.780
20.700
23.750
26.160
28.190

26
39
53
66
92
118
158
250
323
387
466

38
59
78
98
137
176
235
372
481
576
694

61
92
115
139
173
240
301
468
624
747
875

91
137
171
207
257
357
448
696
929
1112
1302

12-E-CPE-2-FLAT 2 FLAT
12-E-CPE-2
2
12-E-CPE-3
3
12-E-CPE-4
4
12-E-CPE-5
5
12-E-CPE-7
7
12-E-CPE-9
9
12-E-CPE-12
12
12-E-CPE-19
19
12-E-CPE-25
25
12-E-CPE-30
30
12-E-CPE-37
37

12
12
12
12
12
12
12
12
12
12
12
12

7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305
7/.0305

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.080
0.080
0.080
0.080

1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03

.400x.245 10.20x6.20
0.410
10.410
0.435
11.050
0.475
12.070
0.520
13.210
0.595
15.110
0.695
17.650
0.765
19.430
0.940
23.880
1.095
27.810
1.150
29.210
1.240
31.500

42
42
64
85
106
149
191
247
391
515
618
762

63
63
95
127
158
221
285
368
582
767
920
1134

82
94
124
157
191
268
337
428
688
854
1002
1240

122
140
185
234
284
399
502
637
1024
1271
1491
1845

10-E-CPE-2-FLAT 2 FLAT
10-E-CPE-2
2
10-E-CPE-3
3
10-E-CPE-4
4
10-E-CPE-5
5
10-E-CPE-7
7
10-E-CPE-9
9
10-E-CPE-12
12

10
10
10
10
10
10
10
10

7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385
7/.0385

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080

1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03

.445x.270
0.455
0.485
0.560
0.615
0.670
0.760
0.950

64
65
100
134
167
234
295
402

95
97
150
199
249
349
440
598

113
128
172
234
284
381
464
651

168
190
256
348
423
567
691
969

11.30x6.90
11.560
12.320
14.220
15.620
17.020
19.300
22.990

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
511
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Power Cable
EPR Insulated Conductors
CPE Jacket, 600V
Applications
As flame-retardant three or four conductor power cables rated 600V, 90C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.
Construction
Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink with a Class B
stranded uninsulated tinned annealed copper grounding conductor and CPE jacket overall, surface
printed.
Standards
UL 44 Type XHHW-2
UL 1277 Type TC-ER, UL File # E57179
UL 1581
ICEA S-95-658/NEMA WC70
UL 1581 VW-1
UL 1277
IEEE 383
IEEE 1202
CSA FT4
ICEA T-29-520
Color Code ICEA Method 4
Notes
Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30C ambient temperature.
Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

CONTROL CABLES

Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
FRXLP Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

512
20140110

Power Cable
EPR Insulated Conductors
CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Size
Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal


Strand
Wire Insulation Insulation Jacket
Jacket
Size Thickness Thickness Thickness Thickness
AWG
(in)
(mm)
(in)
(mm)
7/.0242
14
0.0300
0.76
0.045
1.14
7/.0305
12
0.0300
0.76
0.045
1.14
7/.0385
10
0.0300
0.76
0.060
1.52

Nominal Nominal
Cable
Cable
O.D.
O.D.
(in)
(mm)
0.430
10.92
0.480
12.19
0.565
14.35

Copper
Weight
/MFT
(lb)
55
87
136

Copper
Weight
/km
(kg)
82
129
202

Approx.
Weight
/MFT
(lb)
118
160
237

Approx.
Weight
/Km
(kg)
176
238
353

3EEPR-14
3EEPR-12
3EEPR-10

3
3
3

14
12
10

3EEPR-8
4EEPR-8

3
4

8
8

7/.0486
7/.0486

10
10

0.045
0.045

1.14
1.14

0.060
0.060

1.52
1.52

0.655
0.720

16.64
18.29

190
242

283
360

314
393

467
585

3EEPR-6
4EEPR-6

3
4

6
6

7/.0612
7/.0612

8
8

0.045
0.045

1.14
1.14

0.060
0.060

1.52
1.52

0.740
0.790

18.80
20.07

297
384

442
571

456
561

679
835

3EEPR-4
4EEPR-4

3
4

4
4

7/.0772
7/.0772

8
8

0.045
0.045

1.14
1.14

0.080
0.080

2.03
2.03

0.880
0.950

22.35
24.13

442
578

658
861

642
822

955
1223

3EEPR-2
4EEPR-2

3
4

2
2

7/.0974
7/.0974

6
6

0.045
0.045

1.14
1.14

0.080
0.080

2.03
2.03

1.010
1.090

25.65
27.69

703
919

1046
1368

979
1235

1457
1838

3EEPR-1
4EEPR-1

3
4

1
1

19/.0664
19/.0664

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.120
1.235

28.45
31.37

872
1136

1298
1691

1021
1521

1594
2264

3EEPR-1/0
4EEPR-1/0

3
4

1/0
1/0

19/.0745
19/.0745

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.225
1.330

31.12
33.78

1069
1413

1591
2103

1439
1820

2142
2709

3EEPR-2/0
4EEPR-2/0

3
4

2/0
2/0

19/.0837
19/.0837

6
6

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.300
1.440

33.02
36.58

1340
1760

1994
2619

1720
2208

2560
3286

3EEPR-3/0
4EEPR-3/0

3
4

3/0
3/0

19/.0940
19/.0940

4
4

0.055
0.055

1.40
1.40

0.080
0.080

2.03
2.03

1.420
1.570

36.07
39.88

1717
2245

2555
3341

2176
2788

3238
3405

3EEPR-4/0
4EEPR-4/0

3
4

4/0
4/0

19/.1055
19/.1055

4
4

0.055
0.055

1.40
1.40

0.080
0.110

2.03
2.79

1.540
1.790

39.12
45.47

2130
2796

3170
4161

2614
3495

3890
5201

3EEPR-250
4EEPR-250

3
4

250
250

37/.0822
37/.0822

4
4

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

1.760
1.915

44.70
48.64

2494
3282

3712
4884

3184
4019

4738
5981

3EEPR-350
4EEPR-350

3
4

350
350

37/.0973
37/.0973

3
3

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

1.960
2.165

49.78
54.99

3474
4577

5170
6811

4187
5436

6231
8090

3EEPR-500
4EEPR-500

3
4

500
500

37/.1162
37/.1162

2
2

0.065
0.065

1.65
1.65

0.110
0.110

2.79
2.79

2.245
2.475

57.02
62.87

4934
6509

7343
9687

5847
7607

8702
11321

3EEPR-750
4EEPR-750

3
4

750
750

61/.1109
61/.1109

1
1

0.080
0.080

2.03
2.03

0.140
0.140

3.56
3.56

2.810
3.115

71.37
79.12

7278
9712

10831
14453

9145
11805

13610
17569

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
512
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Control Cable
FR-EPR Insulated Conductors
Copper Shield, CPE Jacket, 600V
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 colorcoded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.
Standards
TC Type Tray Cable per Article 340 of the NEC.
Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
Individual conductors approved as Type XHHW.
Cables Pass IEEE-383 ribbon burner flame test.
Overall jacket approved as Sunlight Resistant.
Cables meet requirements of ICEA S-73-532/NEMA WC57 for control cables.
Notes
Cables may be supplied with an insulated ground and marked Open Wiring.
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color Coding: ICEA Method 1, Table E-1
FRXLP Insulation
PVC, CSPE, LSOH Jackets
Insulated ground wires or bare ground wires
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

513
20140110

Control Cable
FR-EPR Insulated Conductors
Copper Shield, CPE Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Copper
Shield
Thickness
(in)

Copper
Shield
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approx.
Cable
Weight
/MFT
(lb)

Approx.
Cable
Weight
/Km
(kg)

14-402ESH
14-403ESH
14-404ESH
14-405ESH
14-407ESH
14-409ESH
14-412ESH

2
3
4
5
7
9
12

14
14
14
14
14
14
14

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.045
.045
.060
.060
.060
.060

1.1
1.1
1.1
1.5
1.5
1.5
1.5

0.445
0.470
0.505
0.580
0.620
0.705
0.785

11.3
11.9
12.8
14.7
15.7
17.9
19.9

109
132
155
207
246
311
393

162
196
231
308
366
463
585

12-452ESH
12-453ESH
12-454ESH
12-455ESH
12-457ESH
12-459ESH
12-462ESH

2
3
4
5
7
9
12

12
12
12
12
12
12
12

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.045
.060
.060
.060
.060
.080

1.1
1.1
1.5
1.5
1.5
1.5
2.0

0.485
0.510
0.585
0.630
0.675
0.775
0.905

12.3
13.0
14.9
16.0
17.1
19.7
23.0

137
163
225
259
322
409
552

204
243
335
385
479
609
821

10-502ESH
10-503ESH
10-504ESH
10-505ESH
10-507ESH
10-509ESH
10-512ESH

2
3
4
5
7
9
12

10
10
10
10
10
10
10

7
7
7
7
7
7
7

.005
.005
.005
.005
.005
.005
.005

0.13
0.13
0.13
0.13
0.13
0.13
0.13

.045
.060
.060
.060
.060
.080
.080

1.1
1.5
1.5
1.5
1.5
2.0
2.0

0.535
0.595
0.640
0.695
0.750
0.910
1.010

13.6
15.1
16.3
17.7
19.1
23.1
25.7

179
234
289
340
442
590
748

266
348
430
506
658
878
1113

08-552ESH
08-553ESH
08-554ESH

2
3
4

8
8
8

7
7
7

.005
.005
.005

0.13
0.13
0.13

.060
.060
.060

1.5
1.5
1.5

0.695
0.735
0.795

17.7
18.7
20.2

288
365
444

429
543
661

06-602ESH
06-603ESH
06-603ESH

2
3
4

6
6
6

7
7
7

.005
.005
.005

0.13
0.13
0.13

.060
.060
.080

1.5
1.5
2.0

0.775
0.820
0.935

19.7
20.8
23.4

378
494
645

562
735
956

04-502ESH
04-503ESH
04-554ESH

2
3
4

4
4
4

7
7
7

.005
.005
.005

0.13
0.13
0.13

.080
.080
.080

2.0
2.0
2.0

0.915
0.965
1.055

23.2
24.5
26.8

550
722
903

818
1074
1344

02-503ESH
02-554ESH
02-554ESH

2
3
4

2
2
2

7
7
7

.005
.005
.005

0.13
0.13
0.13

.080
.080
.080

2.0
2.0
2.0

1.035
1.100
1.200

26.3
27.9
30.5

758
1007
1288

1128
1498
1917

01-503ESH
01-554ESH

2
3

1
1

19
19

.005
.005

0.13
0.13

.080
.080

2.0
2.0

1.230
1.350

31.2
34.3

1236
1564

1839
2327

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
513
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

20/10 Control Cable


PE/PVC Insulated Conductors
PVC Jacket, 600V
Applications
Standard general purpose control cable for important control circuits in industrial plants and station
control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or
trough and direct burial. For metering installations where insulated conductors are subject to sunlight degradation, these cables can be jacketed with special UV-resistant compounds.
Construction
Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation,
10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or
more conductors twisted with suitable fillers where necessary to make round, polyester tape over
assembly, PVC jacket overall, surface printed.
Standards
Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57.
Notes
Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl
chloride jacket, 600V.
Color coding is ICEA Appendix E Method 1 Table E-1.
Options
Flexible stranded conductors
Tin-coated copper conductors per ASTM B33
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

Item #

Conductor
Size
AWG

Conductor
Stranding

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

2
3
4
5
7
9
12
15
19
25
30
37

14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7

.045
.045
.045
.045
.045
.060
.060
.060
.060
.080
.080
.080

1.1
1.1
1.1
1.1
1.1
1.5
1.5
1.5
1.5
2.0
2.0
2.0

.235 x .375
0.400
0.435
0.475
0.515
0.640
0.710
0.785
0.825
1.030
1.065
1.150

5.97 x 9.53
10.2
11.0
12.1
13.1
16.3
18.0
19.9
21.0
26.2
27.1
29.2

Approximate Approximate
Cable Weight Cable Weight
/MFT
/Km
(lb)
(kg)
63
95
117
132
174
238
305
370
453
624
693
832

93
141
173
195
258
352
451
548
670
924
1026
1231

CONTROL CABLES

14-CTB-2
14-CTB-3
14-CTB-4
14-CTB-5
14-CTB-7
14-CTB-9
14-CTB-12
14-CTB-15
14-CTB-19
14-CTB-25
14-CTB-30
14-CTB-37

Number of
Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

514
20140110

20/10 Control Cable


PE/PVC Insulated Conductors
PVC Jacket, 600V

CONTROL CABLES

Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approximate Approximate
Cable Weight Cable Weight
/MFT
/Km
(lb)
(kg)

12-CTB-2
12-CTB-3
12-CTB-4
12-CTB-5
12-CTB-7
12-CTB-9
12-CTB-12
12-CTB-15
12-CTB-19
12-CTB-25
12-CTB-30
12-CTB-37

2
3
4
5
7
9
12
15
19
25
30
37

12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7

.045
.045
.045
.045
.060
.060
.060
.080
.080
.080
.080
.080

1.1
1.1
1.1
1.1
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

.255 x .415
0.445
0.485
0.560
0.610
0.715
0.795
0.920
0.970
1.150
1.195
1.290

6.48 x 10.50
11.3
12.3
14.2
15.5
18.2
20.2
23.4
24.6
29.2
30.4
32.8

85
126
158
200
259
328
423
554
675
865
1020
1234

126
186
234
296
383
485
626
820
999
1280
1510
1826

10-CTB-2
10-CTB-3
10-CTB-4
10-CTB-5
10-CTB-7
10-CTB-9
10-CTB-12
10-CTB-15
10-CTB-19
10-CTB-25
10-CTB-30
10-CTB-37

2
3
4
5
7
9
12
15
19
25
30
37

10
10
10
10
10
10
10
10
10
10
10
10

7
7
7
7
7
7
7
7
7
7
7
7

.045
.045
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080

1.1
1.1
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0

.280 x .460
0.495
0.580
0.625
0.680
0.805
0.935
1.035
1.090
1.300
1.350
1.460

7.11 x 11.7
12.6
14.7
15.9
17.3
20.4
23.7
26.3
27.7
33.0
34.3
37.1

116
170
235
274
364
462
638
780
958
1245
1464
1778

171
252
348
406
539
684
944
1154
1418
1843
2167
2631

9-CTB-2
9-CTB-3
9-CTB-4
9-CTB-5
9-CTB-7
9-CTB-9
9-CTB-12
9-CTB-15
9-CTB-19
9-CTB-25
9-CTB-30
9-CTB-37

2
3
4
5
7
9
12
15
19
25
30
37

9
9
9
9
9
9
9
9
9
9
9
9

7
7
7
7
7
7
7
7
7
7
7
7

.045
.045
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080

1.1
1.1
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0

.290 x .490
0.520
0.600
0.660
0.720
0.845
0.985
1.095
1.150
1.380
1.430
1.545

7.37 x 12.4
13.2
15.2
16.8
18.3
21.5
25.0
27.8
29.2
35.1
36.3
39.2

132
188
258
313
418
530
731
896
1100
1433
1688
2050

195
278
382
463
619
784
1082
1326
1628
2121
2499
3034

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
514
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

20/10 Control Cable


PE/PVC Insulated Conductors
Shielded, PVC Jacket, 600V
Applications
Standard general purpose control cable for important control circuits in industrial plants and station
control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or
trough and direct burial. For metering installations where insulated conductors are exposed to sunlight degradations, these cables can be jacketed with special UV-resistant compounds.
Construction
Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation,
10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or
more conductors twisted with suitable fillers where necessary to make round, polyester tape over
assembly, copper tape shield, PVC jacket overall, surface printed.
Standards
Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57.
Notes
Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl
chloride jacket, 600V.
Color coding is ICEA Appendix E Method 1 Table E-1.
Options
Flexible stranded conductors
Tin-coated copper conductors per ASTM B33
Copper braid shield
1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.

Item #

Conductor
Size
AWG

Conductor
Stranding

Copper
Shield
Thickness
(in)

Copper
Shield
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approx.
Cable
Weight
/MFT
(lb)

Approx.
Cable
Weight
/Km
(kg)

10-CTB-2-S
10-CTB-3-S
10-CTB-4-S

2
3
4

10
10
10

7
7
7

.005
.005
.005

0.1
0.1
0.1

.060
.060
.060

1.5
1.5
1.5

0.600
0.640
0.695

15.2
16.3
17.7

233
285
333

345
423
493

9-CTB-3-S
9-CTB-4-S
9-CTB-5-S

3
4
5

9
9
9

7
7
7

.005
.005
.005

0.1
0.1
0.1

.060
.060
.060

1.5
1.5
1.5

0.620
0.670
0.725

15.7
17.0
18.4

258
318
377

382
471
558

8-CTB-3-S
8-CTB-4-S

3
4

8
8

7
7

.005
.005

0.1
0.1

.060
.080

1.5
2.0

0.805
0.920

20.4
23.4

391
511

579
756

6-CTB-3-S
6-CTB-4-S

3
4

6
6

7
7

.005
.005

0.1
0.1

.080
.080

2.0
2.0

0.980
1.065

24.9
27.1

585
722

866
1069

4-CTB-3-S
4-CTB-4-S

3
4

4
4

7
7

.005
.005

0.1
0.1

.080
.080

2.0
2.0

1.090
1.190

27.7
30.2

771
982

1141
1453

2-CTB-3-S
2-CTB-4-S

3
4

2
2

7
7

.005
.005

0.1
0.1

.080
.080

2.0
2.0

1.225
1.345

31.1
34.2

1076
1369

1592
2026

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

515
20140110

CONTROL CABLES

Number of
Conductors

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TFN, THWN or THHN Insulated Conductors


PVC Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in dry locations, 75C in wet locations. Specifically approved for installation in cable trays per Article 336 of the
NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the
NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may
be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10
AWG), color-coded, two conductors flat, three or more conductors twisted, PVC jacket overall, surface printed.
Standards
Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).
Overall jacket UL listed as Sunlight Resistant.
Cables UL listed for Direct Burial.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
Cables designated (w/g) contain an additional bare copper grounding conductor, same size as circuit conductors, and are UL listed for Open Wiring.
Standard color-coding is ICEA Method E2 or K2 for NEC applications. This color-coding method
omits white and green from the color sequence.
ICEA Method 4 color-coding is also provided. This consists of printed numbers and words, 1-ONE,
2-TWO, etc.
Size 16 AWG is rated 90C dry only.

Item #

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

2
3
3 w/g
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
N/A
45
45
45
45
45
45
45
45
60
60
60
60
60
60
60
60
60
60
60

.20 x .30
0.32
N/A
0.34
0.37
0.40
0.40
0.44
0.47
0.51
0.51
0.55
0.56
0.58
0.61
0.61
0.64
0.64
0.64
0.67
0.70
0.74

40
60
N/A
75
85
100
110
130
140
155
170
200
210
225
240
250
265
275
285
305
340
370

CONTROL CABLES

16-TC1-2
16-TC1-3
16-TC1-3 w/g
16-TC1-4
16-TC1-5
16-TC1-6
16-TC1-7
16-TC1-8
16-TC1-9
16-TC1-10
16-TC1-11
16-TC1-12
16-TC1-13
16-TC1-14
16-TC1-15
16-TC1-16
16-TC1-17
16-TC1-18
16-TC1-19
16-TC1-20
16-TC1-23
16-TC1-25

Number of
Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

517
20140902

TFN, THWN or THHN Insulated Conductors


PVC Jacket, 600V
Item #

Number of
Conductors

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

27
29
31
32
37

16
16
16
16
16

7
7
7
7
7

60
60
60
60
80

0.76
0.77
0.80
0.82
0.89

395
420
445
460
550

14-TC1-2
14-TC1-3
14-TC1-3 w/g
14-TC1-4
14-TC1-5
14-TC1-6
14-TC1-7
14-TC1-8
14-TC1-9
14-TC1-10
14-TC1-11
14-TC1-12
14-TC1-13
14-TC1-14
14-TC1-15
14-TC1-16
14-TC1-17
14-TC1-18
14-TC1-19
14-TC1-20
14-TC1-23
14-TC1-25
14-TC1-27
14-TC1-29
14-TC1-31
14-TC1-32
14-TC1-37

2
3
3 w/g
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
45
45
45
45
45
60
60
60
60
60
60
60
60
60
60
60
60
80
80
80
80
80
80

.21 x .33
0.34
0.35
0.37
0.41
0.44
0.44
0.48
0.51
0.58
0.58
0.60
0.62
0.64
0.66
0.66
0.70
0.70
0.70
0.73
0.78
0.85
0.88
0.90
0.92
0.94
0.96

55
75
92
100
115
140
150
170
195
220
240
265
280
295
310
340
355
370
390
415
475
540
570
600
640
660
755

12-TC1-2
12-TC1-3
12-TC1-3 w/g
12-TC1-4
12-TC1-5
12-TC1-6
12-TC1-7
12-TC1-8
12-TC1-9
12-TC1-10
12-TC1-11
12-TC1-12

2
3
3 w/g
4
5
6
7
8
9
10
11
12

12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
45
45
45
60
60
60
60
60

.23 x .37
0.36
0.40
0.40
0.45
0.50
0.50
0.58
0.62
0.66
0.66
0.68

75
105
130
135
165
195
215
260
300
325
350
375

CONTROL CABLES

16-TC1-27
16-TC1-29
16-TC1-31
16-TC1-32
16-TC1-37

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
517
20140902

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

TFN, THWN or THHN Insulated Conductors


PVC Jacket, 600V
Item #

12-TC1-13
12-TC1-14
12-TC1-15
12-TC1-16
12-TC1-17
12-TC1-18
12-TC1-19
12-TC1-20
12-TC1-23
12-TC1-25
12-TC1-27
12-TC1-29
12-TC1-31
12-TC1-32
12-TC1-37

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

60
60
60
60
60
60
60
80
80
80
80
80
80
80
80

0.70
0.73
0.76
0.76
0.79
0.79
0.79
0.89
0.93
0.96
1.00
1.01
1.06
1.08
1.10

400
425
455
485
515
545
656
590
690
770
840
910
950
1000
1090

2
3
3 w/g
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

.26 x .43
0.46
0.47
0.50
0.58
0.63
0.63
0.69
0.73
0.81
0.81
0.82
0.89
0.92
0.95
0.95
1.02
1.02
1.02
1.07
1.12
1.19
1.22
1.23
1.29
1.31
1.36

110
155
194
200
265
315
345
420
450
500
540
580
680
725
745
810
860
900
940
990
1120
1210
1295
1375
1465
1510
1710

CONTROL CABLES

10-TC1-2
10-TC1-3
10-TC1-3 w/g
10-TC1-4
10-TC1-5
10-TC1-6
10-TC1-7
10-TC1-8
10-TC1-9
10-TC1-10
10-TC1-11
10-TC1-12
10-TC1-13
10-TC1-14
10-TC1-15
10-TC1-16
10-TC1-17
10-TC1-18
10-TC1-19
10-TC1-20
10-TC1-23
10-TC1-25
10-TC1-27
10-TC1-29
10-TC1-31
10-TC1-32
10-TC1-37

Number of
Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

517
20140902

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

TFN, THWN or THHN Insulated Conductors


Overall Shield, Drain Wire, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90C in dry locations. 75C in wet locations. Specifically approved for installation in cable trays per Article 336 of the
NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the
NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may
be installed in air, in ducts or conduits, in tray or trough, are suitable for direct burial.
Construction
Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10
AWG), color-coded, cabled singles, overall aluminum/polyester foil tape plus tinned Cu drain wire,
PVC jacket, surface printed.
Standards
Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).
Overall jacket UL listed as Sunlight Resistant.
Cables UL listed for Direct Burial.
Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
Drain wire 18 AWG on size 16 AWG conductor constructions, and 16 AWG on all other sizes.
Class 1 circuits as defined in Article 725.
Class 1, Division II Hazardous Locations per Article 501.4(B).
Aerial use permitted with a messenger.
Standard Color Coding also available ICEA Method 1, Table E-1

Item #

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
45
45
45
45
45
45
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
80

0.32
0.32
0.34
0.37
0.40
0.40
0.44
0.47
0.51
0.51
0.55
0.56
0.58
0.61
0.61
0.64
0.64
0.64
0.67
0.70
0.74
0.76
0.77
0.80
0.82
0.89

54
60
75
85
100
110
130
140
155
170
200
210
225
240
250
265
275
285
305
340
370
395
420
445
460
550

CONTROL CABLES

16-TCCU-2
16-TCCU-3
16-TCCU-4
16-TCCU-5
16-TCCU-6
16-TCCU-7
16-TCCU-8
16-TCCU-9
16-TCCU-10
16-TCCU-11
16-TCCU-12
16-TCCU-13
16-TCCU-14
16-TCCU-15
16-TCCU-16
16-TCCU-17
16-TCCU-18
16-TCCU-19
16-TCCU-20
16-TCCU-23
16-TCCU-25
16-TCCU-27
16-TCCU-29
16-TCCU-31
16-TCCU-32
16-TCCU-37

Number of
Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

518
20140902

TFN, THWN or THHN Insulated Conductors


Overall Shield, Drain Wire, 600V

CONTROL CABLES

Item #

Number of
Conductors

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

14-TCCU-2
14-TCCU-3
14-TCCU-4
14-TCCU-5
14-TCCU-6
14-TCCU-7
14-TCCU-8
14-TCCU-9
14-TCCU-10
14-TCCU-11
14-TCCU-12
14-TCCU-13
14-TCCU-14
14-TCCU-15
14-TCCU-16
14-TCCU-17
14-TCCU-18
14-TCCU-19
14-TCCU-20
14-TCCU-23
14-TCCU-25
14-TCCU-27
14-TCCU-29
14-TCCU-31
14-TCCU-32
14-TCCU-37

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
45
45
45
45
60
60
60
60
60
60
60
60
60
60
60
60
80
80
80
80
80
80

0.34
0.34
0.37
0.41
0.44
0.44
0.48
0.51
0.58
0.58
0.60
0.62
0.64
0.66
0.66
0.70
0.70
0.70
0.73
0.78
0.85
0.88
0.90
0.92
0.94
0.96

71
75
100
115
140
150
170
195
220
240
265
280
295
310
340
355
370
390
415
475
540
570
600
640
660
755

12-TCCU-2
12-TCCU-3
12-TCCU-4
12-TCCU-5
12-TCCU-6
12-TCCU-7
12-TCCU-8
12-TCCU-9
12-TCCU-10
12-TCCU-11
12-TCCU-12
12-TCCU-13
12-TCCU-14

2
3
4
5
6
7
8
9
10
11
12
13
14

12
12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
45
45
45
45
45
60
60
60
60
60

0.36
0.36
0.40
0.45
0.50
0.50
0.58
0.62
0.66
0.66
0.68
0.70
0.73

90
105
135
165
195
215
260
300
325
350
375
400
425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
518
20140902

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

TFN, THWN or THHN Insulated Conductors


Overall Shield, Drain Wire, 600V
Item #

Size
AWG

Number of
Strands

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Weight
/MFT
(lb)

12-TCCU-15
12-TCCU-16
12-TCCU-17
12-TCCU-18
12-TCCU-19
12-TCCU-20
12-TCCU-23
12-TCCU-25
12-TCCU-27
12-TCCU-29
12-TCCU-31
12-TCCU-32
12-TCCU-37

15
16
17
18
19
20
23
25
27
29
31
32
37

12
12
12
12
12
12
12
12
12
12
12
12
12

7
7
7
7
7
7
7
7
7
7
7
7
7

60
60
60
60
60
60
60
80
80
80
80
80
80

0.76
0.76
0.79
0.79
0.79
0.89
0.93
0.96
1.00
1.01
1.06
1.08
1.10

455
485
515
545
565
590
690
770
840
910
950
1000
1090

10-TCCU-2
10-TCCU-3
10-TCCU-4
10-TCCU-5
10-TCCU-6
10-TCCU-7
10-TCCU-8
10-TCCU-9
10-TCCU-10
10-TCCU-11
10-TCCU-12
10-TCCU-13
10-TCCU-14
10-TCCU-15
10-TCCU-16
10-TCCU-17
10-TCCU-18
10-TCCU-19
10-TCCU-20
10-TCCU-23
10-TCCU-25
10-TCCU-27
10-TCCU-29
10-TCCU-31
10-TCCU-32
10-TCCU-37

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
25
27
29
31
32
37

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

45
45
45
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

0.46
0.46
0.50
0.58
0.63
0.63
0.69
0.73
0.81
0.81
0.82
0.89
0.92
0.95
0.95
1.02
1.02
1.02
1.07
1.12
1.19
1.22
1.23
1.29
1.31
1.36

126
155
200
265
315
345
420
450
500
540
580
680
725
745
810
860
900
940
990
1120
1210
1295
1375
1465
1510
1710

CONTROL CABLES

Number of
Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

518
20140902

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

THWN or THHN Insulated Conductors with Ground


PVC Jacket, 600V
Applications
As flame-retardant three or four conductor power cables rated 600V, 90C in dry locations. 75C in
wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC
cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.
Construction
Individual conductors of stranded uncoated copper Type THWN or THHN, surface print phase identification. Three or four insulated conductors twisted with a Class B stranded uncoated copper
grounding conductor and fillers, cable tape, PVC jacket overall, surface printed.
Standards
Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
Individual conductors UL listed as Type THWN or THHN.
Overall jacket UL listed as Sunlight Resistant.
Cables UL listed for Direct Burial.
Cables UL listed for Open Wiring.
Cables and color coding pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
Ampacity in accordance with the National Electric Code for cables in uncovered cable tray without
maintained space and for cable in raceway or direct buried. 90C conductor temperature for dry
locations, 75C conductor temperature for wet locations, 30C ambient temperature.
Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

Item#

Number of
Conductors

Size
AWG or
KCM

Number of
Strands

PVC
Insulation
Thickness
(mil)

Nylon
Jacket
Thickness
(mil)

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Grounding
Conductor
Size AWG

Weight
/MFT
(lb)

3
3
3
3
3
3
3
3
3
3
3
3
3
3

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000

7
7
7
7
19
19
19
19
19
37
37
37
61
61

30
30
40
40
50
50
50
50
50
60
60
60
70
70

5
5
6
6
7
7
7
7
7
8
8
8
9
9

60
60
80
80
80
80
80
80
80
110
110
110
110
140

0.62
0.70
0.88
1.01
1.14
1.23
1.32
1.42
1.56
1.76
1.98
2.26
2.71
3.10

10
8
8
6
6
6
6
4
4
4
3
2
1
1/0

315
445
675
995
1200
1480
1770
2180
2690
3225
4370
5960
9050
11720

3 Conductor

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

519
20140902

CONTROL CABLES

TC3-8
TC3-6
TC3-4
TC3-2
TC3-1
TC3-1/0
TC3-2/0
TC3-3/0
TC3-4/0
TC3-250
TC3-350
TC3-500
TC3-750
TC3-1000

THWN or THHN with Ground


PVC Jacket, 600V
Item#

Number of
Conductors

Size
AWG or
KCM

Number of
Strands

PVC
Insulation
Thickness
(mil)

Nylon
Jacket
Thickness
(mil)

Overall
PVC Jacket
(mil)

Nominal
Diameter
(in)

Grounding
Conductor
Size AWG

Weight
/MFT
(lb)

4
4
4
4
4
4
4
4
4
4
4
4
4

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
750

7
7
7
7
19
19
19
19
19
37
37
37
61

30
30
40
40
50
50
50
50
50
60
60
60
70

5
5
6
6
7
7
7
7
7
8
8
8
9

60
60
80
80
80
80
80
80
110
110
110
110
140

0.68
0.76
0.97
1.11
1.26
1.36
1.47
1.58
1.79
1.95
2.20
2.51
3.07

12
10
10
9
9
9
9
7
7
7
6
5
4

405
555
846
1256
1515
1913
2351
2760
3545
4148
5480
7924
11340

4 Conductor

CONTROL CABLES

TC4-8
TC4-6
TC4-4
TC4-2
TC4-1
TC4-1/0
TC4-2/0
TC4-3/0
TC4-4/0
TC4-250
TC4-350
TC4-500
TC4-750

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
519
20140902

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Aluminum Three Conductor UL


Type TC 600V
Applications
These cables are specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways,
or where supported in outdoor locations by a messenger wire.
In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits
per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with
NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the
utilization equipment or device.
Construction
Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conductors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The
sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly.
PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2
conductors that are phase identified, including one insulated black conductor, one insulated white
conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth insulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with crosslinked polyethylene (XLPE) and rated for a maximum operating temperature of 90C in dry and wet
locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC.
Standards
UL 1277 Type TC Tray Cable
UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2
ICE A S-73-5 32
NEMA WC57 Standard for Control Cables
ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less
Notes
Terminates safely with industry standard dual rated terminals and connectors.

Item #

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Nominal
Diameter
(in)

Nominal
Weight
(lb/MFT)

Package
Length
(ft)

Ampacity
90C

Ampacity
75C

45
45
45
55
55
55
55
55
65
65
65
65
65
65
80
80
80
80
80
80

60
60
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
140
140
140

0.76
0.82
0.95
1.08
1.14
1.22
1.32
1.43
1.57
1.74
1.74
1.83
1.94
2.11
2.34
2.47
2.54
2.80
2.91
3.19

234
293
431
544
629
739
872
1061
1238
1524
1559
1711
1888
2251
2692
3069
3244
4059
4271
5786

1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
500
500
500

75
75
100
115
135
150
175
205
230
260
260
280
305
350
385
425
435
480
480
480

50
65
90
100
120
135
155
180
205
230
230
250
270
310
340
375
385
425
425
425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

529
20140626

CONTROL CABLES

A6-03XHPGTC-6
A4-03XHPGTC-6
A2-03XHPGTC-6
A1-03XHPGTC-4
A1/0-03XHPGTC-4
A2/0-03XHPGTC-4
A3/0-03XHPGTC-4
A4/0-03XHPGTC-2
A250-03XHPGTC-2
A300-03XHPGTC-2
A300-03XHPGTC-1/0
A350-03XHPGTC-2
A400-03XHPGTC-1
A500-03XHPGTC-1
A600-03XHPGTC-1
A700-03XHPGTC-1/0
A750-03XHPGTC-1/0
A900-03XHPGTC-250
A900-03XHPGTC-400
A900-03XHPGTC-750

Conductor No. of Grounding


Size
Phase Conductor
AWG Conductors AWG
or kcmil
or kcmil
6
3
6
4
3
6
2
3
6
1
3
4
1/0
3
4
2/0
3
4
3/0
3
4
4/0
3
2
250
3
2
300
3
2
300
3
1/0
350
3
2
400
3
1
500
3
1
600
3
1
700
3
1/0
750
3
1/0
900
3
250
900
3
400
900
3
750

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Aluminum Four Conductor UL


Type TC 600V
Applications
These cables are specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways,
or where supported in outdoor locations by a messenger wire.
In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits
per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with
NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the
utilization equipment or device.
Construction
Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conductors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The
sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly.
PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2
conductors that are phase identified, including one insulated black conductor, one insulated white
conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth insulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with crosslinked polyethylene (XLPE) and rated for a maximum operating temperature of 90C in dry and wet
locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC.
Standards
UL 1277 Type TC Tray Cable
UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2
ICE A S-73-5 32
NEMA WC57 Standard for Control Cables
ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less
Notes
Terminates safely with industry standard dual rated terminals and connectors.

Item #

Insulation
Thickness
(mil)

Jacket
Thickness
(mil)

Nominal
Diameter
(in)

Nominal
Weight
(lb/MFT)

Package
Length
(ft)

Ampacity
90C

Ampacity
75C

45
45
45
55
55
55
55
55
65
65
65
65
65
80
80
80
80
80
80
80
80

80
80
80
80
80
80
80
80
110
110
110
110
110
110
140
140
140
140
140
140
140

0.87
0.95
1.06
1.21
1.28
1.36
1.46
1.61
1.83
1.93
2.05
2.15
2.34
2.59
2.80
2.88
3.34
3.10
3.13
3.28
3.53

315
400
526
683
797
928
1097
1346
1704
1948
2217
2416
2906
3477
4094
4363
5234
5067
5163
5405
5919

1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
500
500
500
500

55
75
100
115
135
150
175
205
230
260
280
305
350
385
425
435
435
480
480
480
480

50
65
90
100
120
135
155
180
205
230
250
270
310
340
375
385
385
425
425
425
425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

530
20140626

CONTROL CABLES

A6-04XHPGTC-6
A4-04XHPGTC-6
A2-04XHPGTC-6
A1-04XHPGTC-4
A1/0-04XHPGTC-4
A2/0-04XHPGTC-4
A3/0-04XHPGTC-4
A4/0-04XHPGTC-2
A250-04XHPGTC-1
A300-04XHPGTC-1
A350-04XHPGTC-1/0
A400-04XHPGTC-1/0
A500-04XHPGTC-2/0
A600-04XHPGTC-2/0
A700-04XHPGTC-2/0
A750-04XHPGTC-3/0
A750-04XHPGTC-750
A900-04XHPGTC-4/0
A900-04XHPGTC-250
A900-04XHPGTC-400
A900-04XHPGTC-750

Conductor No. of Grounding


Size
Phase Conductor
AWG Conductors AWG
or kcmil
or kcmil
6
4
6
4
4
6
2
4
6
1
4
4
1/0
4
4
2/0
4
4
3/0
4
4
4/0
4
2
250
4
1
300
4
1
350
4
1/0
400
4
1/0
500
4
2/0
600
4
2/0
700
4
2/0
750
4
3/0
750
4
750
900
4
4/0
900
4
250
900
4
400
900
4
750

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Thermocouple Cable
EX, JX, KX, TX
600V
Application
For use as a 600V, multi-pair thermocouple instrumentation cable where flame-retardance, and
moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
Temperature rating of 90C wet or dry. Insulation provides excellent electrical, thermal, and physical
properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40C) cold bend characteristics.
Approved for direct burial.
Construction
Conductor is thermocouple alloy per ANSI MC96.1 1982.
Flame-retardant XLPE insulation.
Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled
together with fillers as needed to form a round core. An overall aluminum mylar shield and drain
wire is applied over the core.
Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes.
Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with
color coded jacket.
Available with class B stranding per ASTM B174.
Standards
Insulated Conductor VW-1
UL Type TC, 90C Wet or Dry, 600V
ICEA S-82-552, 90C Wet or Dry, 600V.
Passes UL 1277 Flame Test (70,000 BTU/hr).
Passes UL 1202 Flame Test (70,000 BTU/hr).
Passes IEEE 383 Flame Test (70,000 BTU/hr).
Passes ICEA T-29-520 Flame Test (210,000 BTU/hr)
EX Color Code
Chromel (Positive) PURPLE
Constantan (Negative) RED
JX Color Code
Iron (Positive) WHITE
Constantan (Negative) RED
TX Color Code
Copper (Positive) BLUE
Constantan (Negative) RED

Notes
Dimensions and weights shown are nominal, subject to industry tolerances. Dimensions and
weights for other cable configurations are available upon request.
Options
PVC Insulation, EPR Insulation
PVC Jacket
300V
Overall shield, shielded pairs overall shield

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

520
20140110

CONTROL CABLES

KX Color Code
Chromel (Positive) YELLOW
Alumel (Negative) RED

Thermocouple Cable
EX, JX, KX, TX
600V
Size AWG

Number of
Shielded Pairs

Insulation
Thickness
(in)

Jacket
Thickness
(in)

Overall
Diameter
(in)

Weight
/MFT
(lb)

ITC-20-1
ITC-20-2
ITC-20-3
ITC-20-4
ITC-20-6
ITC-20-8
ITC-20-10
ITC-20-12
ITC-20-16
ITC-20-24

20
20
20
20
20
20
20
20
20
20

1
2
3
4
6
8
10
12
16
24

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045

0.270
0.035
0.450
0.500
0.600
0.670
0.735
0.790
0.890
1.060

35
70
85
105
160
210
240
280
360
500

ITC-18-1
ITC-18-2
ITC-18-3
ITC-18-4
ITC-18-6
ITC-18-8
ITC-18-10
ITC-18-12
ITC-18-16
ITC-18-24

18
18
18
18
18
18
18
18
18
18

1
2
3
4
6
8
10
12
16
24

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045

0.300
0.480
0.510
0.595
0.670
0.750
0.820
0.930
1.045
1.235

50
90
115
165
220
280
340
430
540
760

ITC-16-1
ITC-16-2
ITC-16-3
ITC-16-4
ITC-16-6
ITC-16-8
ITC-16-10
ITC-16-12
ITC-16-16
ITC-16-24

16
16
16
16
16
16
16
16
16
16

1
2
3
4
6
8
10
12
16
24

0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025
0.025

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045

0.325
0.570
0.600
0.660
0.740
0.880
0.970
1.035
1.165
1.400

60
130
160
200
270
380
460
530
570
960

CONTROL CABLES

Item #

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
520
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

IMSA 19-1 & 20-1


Traffic Control Cable
600V
Application
For use in signal systems in underground conduit/duct, or as aerial cable supported by a messenger, or for installation in buildings.
Construction
Solid Conductor or Stranded Conductor
Polyethylene Insulation, 75C, 600V
19-1: Black PVC Jacket
20-1: Black PE Jacket

Item #

No. of
Conductors

Insulation
Thickness
(in)

Jacket
Wall
Solid
(in)

Jacket
Wall
Stranded
(in)

O.D.
Solid
Solid
(in)

O.D.
Solid
Stranded
(in)

Total
Weight
Solid/MFT
(lb)

Total
Weight
Stranded/MFT
(lb)

IMSA 19-1
IMSA-19-1-14-2
IMSA-19-1-14-3
IMSA-19-1-14-4
IMSA-19-1-14-5
IMSA-19-1-14-7
IMSA-19-1-14-9
IMSA-19-1-14-10
IMSA-19-1-14-12
IMSA-19-1-14-16
IMSA-19-1-14-19
IMSA-19-1-14-20
IMSA-19-1-14-24
IMSA-19-1-14-30
IMSA-19-1-14-37

14
14
14
14
14
14
14
14
14
14
14
14
14
14

2
3
4
5
7
9
10
12
16
19
20
24
30
37

.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080

0.329
0.346
0.377
0.410
0.445
0.517
0.591
0.608
0.672
0.707
0.743
0.823
0.911
0.979

0.347
0.366
0.398
0.435
0.472
0.580
0.627
0.606
0.715
0.752
0.791
0.917
0.968
1.042

62
74
93
114
146
188
221
255
328
377
398
470
605
727

67
79
99
122
156
216
235
272
350
402
424
535
644
774

IMSA-19-1-12-2
IMSA-19-1-12-3
IMSA-19-1-12-4
IMSA-19-1-12-5
IMSA-19-1-12-7
IMSA-19-1-12-9
IMSA-19-1-12-10
IMSA-19-1-12-12
IMSA-19-1-12-16
IMSA-19-1-12-19
IMSA-19-1-12-20
IMSA-19-1-12-24
IMSA-19-1-12-30
IMSA-19-1-12-37

12
12
12
12
12
12
12
12
12
12
12
12
12
12

2
3
4
5
7
9
10
12
16
19
20
24
30
37

.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080

0.383
0.404
0.442
0.483
0.556
0.645
0.699
0.720
0.799
0.882
0.926
1.025
1.084
1.168

0.405
0.428
0.468
0.513
0.589
0.684
0.743
0.766
0.891
0.937
0.985
1.091
1.154
1.245

89
107
135
168
232
297
324
377
490
598
630
745
904
1091

95
113
143
178
246
315
343
399
552
633
667
789
956
1155

CONTROL CABLES

Size
AWG

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

521
20140110

IMSA 19-1 & 20-1


Traffic Control Cable
600V
Size
AWG

No. of
Conductors

Insulation
Thickness
(in)

Jacket
Wall
Solid
(in)

Jacket
Wall
Stranded
(in)

O.D.
Solid
Solid
(in)

O.D.
Solid
Stranded
(in)

Total
Weight
Solid/MFT
(lb)

Total
Weight
Stranded/MFT
(lb)

IMSA 20-1
IMSA-20-1-14-2
IMSA-20-1-14-3
IMSA-20-1-14-4
IMSA-20-1-14-5
IMSA-20-1-14-7
IMSA-20-1-14-9
IMSA-20-1-14-10
IMSA-20-1-14-12
IMSA-20-1-14-16
IMSA-20-1-14-19
IMSA-20-1-14-20
IMSA-20-1-14-24
IMSA-20-1-14-30
IMSA-20-1-14-37

14
14
14
14
14
14
14
14
14
14
14
14
14
14

2
3
4
5
7
9
10
12
16
19
20
24
30
37

.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025

0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080

0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080

0.329
0.346
0.377
0.410
0.445
0.517
0.591
0.608
0.672
0.707
0.743
0.823
0.911
0.979

0.347
0.366
0.398
0.435
0.472
0.580
0.627
0.606
0.715
0.752
0.791
0.917
0.968
1.042

54
66
83
104
135
174
201
234
305
353
372
441
563
681

58
70
89
111
144
196
214
243
325
376
396
493
600
726

IMSA-20-1-12-2
IMSA-20-1-12-3
IMSA-20-1-12-4
IMSA-20-1-12-5
IMSA-20-1-12-7
IMSA-20-1-12-9
IMSA-20-1-12-10
IMSA-20-1-12-12
IMSA-20-1-12-16
IMSA-20-1-12-19
IMSA-20-1-12-20
IMSA-20-1-12-24
IMSA-20-1-12-30
IMSA-20-1-12-37

12
12
12
12
12
12
12
12
12
12
12
12
12
12

2
3
4
5
7
9
10
12
16
19
20
24
30
37

.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.080

0.383
0.404
0.442
0.483
0.556
0.645
0.699
0.720
0.799
0.882
0.926
1.025
1.084
1.168

0.405
0.428
0.468
0.513
0.589
0.684
0.743
0.766
0.891
0.937
0.985
1.091
1.154
1.245

79
96
123
155
214
275
300
351
462
558
587
697
853
1036

84
102
131
165
226
291
317
372
511
590
622
738
902
1097

CONTROL CABLES

Item #

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
521
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

IMSA 19-1 & 20-1


Traffic Control Cable
Shipping Weights
AWG/
Conductors

IMSA 19-1
Solid
Weight /MFT
(lb)

IMSA 19-1
Stranded
Weight /MFT
(lb)

IMSA 20-1
Solid
Weight /MFT
(lb)

IMSA 20-1
Stranded
Weight /MFT
(lb)

16/2
16/3
16/4
16/5
16/7
16/9
16/10
16/12

16/2
16/3
16/4
16/5
16/7
16/9
16/10
16/12

29
44
58
73
102
131
146
175

21
34
48
63
89
111
124
152

14/2
14/3
14/4
14/5
14/7
14/9
14/10
14/12
14/14
14/15
14/16
14/19
14/20
14/21
14/25
14/26

14/2
14/3
14/4
14/5
14/7
14/9
14/10
14/12
14/14
14/15
14/16
14/19
14/20
14/21
14/25
14/26

58
75
94
113
146
186
220
254

311
325
375
395
462
478
497

63
81
98
118
154
212
227
267
312
328
341
393
415
432
544
566

52
66
85
103
136
172
197
232

284
299
348
370
384
450
468

55
71
88
108
141
162
205
244
285
302
316
366
387
405
498
518

12/2
12/3
12/4
12/5
12/7
12/9
12/10
12/12
12/16
12/19
12/20
12/21
12/25

12/2
12/3
12/4
12/5
12/7
12/9
12/10
12/12
12/16
12/19
12/20
12/21
12/25

82
108
135
163
237
281
312
372
449
599
631
663
789

87
113
141
172
244
310
338
393
541
625
658
691
822

74
99
124
152
212
273
296
346
461
547
576
605
720

77
103
130
159
222
284
309
367
501
582
618
643
751

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

521
20140110

CONTROL CABLES

Item #

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA 50-2
Loop Detector Lead-In Wire
600V
Application
Used in municipal signal systems as lead-in cable or for use in communication circuits where a low
capacitance is needed, suitable for underground conduit, as aerial cable supported by messenger,
or in raceways in buildings.
Construction
Unilay stranded tin coated, annealed copper per ASTM-B-33
Twisted pair with overall shield and drain wire
Insulation is high molecular weight PE per UL 758, black and clear
Aluminum/Polyester tape shield helically applied
Polyetheylene Jacket, black
Standards
IMSA Spec No. 50-2-1984.
Also available: NCDOT 1993 and NCDOT 06-031110.

Item #

IMSA-50-2-18
IMSA-50-2-16
IMSA-50-2-14
IMSA-50-2-12

Size
AWG

Stranding

Nominal
Jacket
Thickness
(in)

Nominal
O.D.
(in)

Nominal
Weight
/MFT
(lb)

18
16
14
12

19
19
19
19

.032
.032
.032
.032

.284
.306
.338
.376

31
39
54
75

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

522
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA 51-1 THHN


Loop Detector Lead-In Wire
600V
Application
Designed for use in municipal signal systems as Loop Detector Wire. These wires are installed in
pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is
sent to a traffic signal controller to activate the light changes.
Construction
Conductors: Stranded, uncoated annealed copper per ASTM B-8. Other strandings and tinned conductors available upon special request.
Insulation: Heat stabilized PVC with a nylon jacket per IMSA Specification No. 51.1 paragraph 4 and
6. Insulation color is black.
Standards
Dimensionals physicals and electricals per IMSA SPECIFICATION NO. 51.1

Item #

IMSA-51-1-18
IMSA-51-1-16
IMSA-51-1-14
IMSA-51-1-12
IMSA-51-1-10

Size
AWG

Number of
Strands

Strands
O.D.
(in)

Insulation
Thickness
(in)

Jacket
Wall
(in)

Overall
Diameter
(in)

Weight
/MFT
(lb)

18
16
14
12
10

7
7
7
7
7

.0152
.0192
.0242
.0305
.0385

.015
.015
.015
.015
.015

.004
.004
.004
.004
.004

.085
.097
.112
.131
.165

7
11
16
24
38

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

523
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA 51-3
Loop Detector Wire
600V
Application
Designed for use in municipal signal systems as "Loop Detector Wire". These wires are installed in
pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is
sent to a traffic signal controller to activate the light changes.
Construction
Conductors: Solid or stranded, bare, uncoated copper with separator per ASTM B03 or B08. Other
strandings and tinned conductors available upon special request.
Insulation: Cross-linked polyethylene per IMSA Specification No. 51-3, paragraph 4. Insulation color
is black.
Standards
Tests: Dimensionals, physicals, and electricals per IMSA Specification No. 51-3.
Note
The data listed is approximate and subject to normal manufacturing tolerances. Alternate constructions or materials may be available.

Item #

Size
AWG

Number of
Strands

Strands
O.D.
(in)

Insulation
Thickness
(in)

Overall
Diameter
(in)

Weight
/MFT
(lb)

14
14
14
12
12
10
10
8
6
4
2

Solid
7
19
Solid
7
Solid
7
7
7
7
7

N/A
.0242
.0147
N/A
.0305
N/A
.0385
.0486
.0612
.0772
.0974

.030
.0.0
.030
.030
.030
.030
.030
.045
.045
.045
.045

.125
.135
.135
.145
.155
.165
.180
.240
.275
.325
.380

17
18
18
25
26
38
39
66
99
151
232

IMSA-51-3-14-S
IMSA-51-3-14-7
IMSA-51-3-14-19
IMSA-51-3-12-S
IMSA-51-3-12-7
IMSA-51-3-10-S
IMSA-51-3-107
IMSA-51-3-87
IMSA-51-3-67
IMSA-51-3-47
IMSA-51-3-27
Shipping Weights
Item #

IMSA Spec No.

14
12

51-3
51-3

Description
Insulation Type

Weight /MFT
(lb)

Tinned Copper STR XLPE Insulation


Tinned Copper STR XLPE Insulation

17
29

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

524
20140110

CONTROL CABLES

51-3-14
51-3-12

Size AWG

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA 51-5
Inductant Loop Detector Cable
600V
Application
Used in road pavements to detect vehicles for the purpose of changing signals or determining
amount of traffic flow.
Construction
Single conductor, 600V
PVC/Nylon Insulation in PVC or PE tube jacket, 75C
AWG #14 (2.08mm) one copper conductor per ASTM B-3)
19 strand concentric or bunch stranding
15 mils of black PVC per UL 62
Jacket is clear nylon per ASTM D-4066
Encasing tube is PVC or HDPE compound
Temperature rating: 60C
Voltage rating: 600V
Specifications
IMSA Spec No. 51-5-1984.
Also available: NCDOT 199 and NCDOT 06-24273.
Option
XLPE Insulation

Item #

IMSA-51-5-14
IMSA-51-5-12
Shipping Weights
Item #

Number of
Strands

O.D.
Outside
Diameter
(in)

O.D.
Inside
Diameter
(in)

O.D.
Wall
Thickness
(in)

PVC
Total Weight
/MFT
(lb)

PE
Total Weight
/MFT
(lb)

14
12

19
19

.250
.260

.190
.200

.030
.030

30.00
38.00

25.00
34.00

Size AWG

IMSA Spec No.

Description
Insulation Type

Encasing
Tube

Weight /MFT
(lb)

14
12
14
12
14
12
14
12

51-5
51-5
51-5
51-5
51-5
51-5
51-5
51-5

Bare CU STR XLPE Insulation


Bare CU STR XLPE Insulation
Bare CU STR XLPE Insulation
Bare CU STR XLPE Insulation
Bare CU STR PVC/Nylon Insulation
Bare CU STR PVC/Nylon Insulation
Bare CU STR PVC/Nylon Insulation
Bare CU STR PVC/Nylon Insulation

PVC
PVC
HDPE
HDPE
PVC
PVC
HDPE
HDPE

31
41
33
43
27
36
29
39

CONTROL CABLES

51-5 XLPE/PVC 14
51-5 XLPE/PVC 12
51-5 XLPE/HDPE 14
51-5 XLPE/HDPE 12
51-5 PVC/PVC 14
51-5 PVC/PVC 12
51-5 PVC/HDPE 14
51-5 PVC/HDPE 12

Size
AWG

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

525
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA Cable
Selection Guide
Item #

IMSA
Spec No.

Voltage
Rating

Applications

Installation

Conductor
Configuration

Mechanical
Characteristics

19-1

19-1

600

Aerial or Duct

19-2

600

Cabled
Conductors
Twisted Pairs

PVC Outer Jacket

19-2
19-3

19-3

600

19-4

19-4

600

19-5

19-5

600

Traffic Signal
Fire Protective Signal
Traffic Signal
Fire Protective Signal
Traffic Signal
Fire Protective Signal
Traffic Signal
Fire Protective Signal
Traffic Signal
Fire Protective Signal

16-6

19-6

600

Traffic Signal
Fire Protective Signal

20-1

20-1

600

20-2

20-2

600

20-3

20-3

600

20-4

20-4

600

20-5

20-5

600

20-6

20-6

600

26-3

26-3

Traffic Signal
Aerial or Duct
Fire Protective Signal
Traffic Signal,
Aerial or Duct
Fire Protective Signal
Traffic Signal
Figure-8 Aerial
Fire Protective Signal
Integral Msgr.
Traffic Signal
Figure-8 Aerial
Fire Protective Signal
Integral Msgr.
Traffic Signal
Aerial, Duct or Buried
Fire Protective Signal
Traffic Signal
Aerial, Duct or Buried
Fire Protective Signal
Signal Systems
Aerial Self-Supporting
Copper Conductor

28-3

28-3

29-1

29-1

29-2

29-2

29-3

29-3

29-4

29-4

39-2

39-2

300

Signal Systems

Aerial or Duct
Figure-8 Aerial
Integral Msgr.
Figure-8 Aerial
Integral Msgr.
Aerial, Duct or Buried

Cabled
Conductors
Twisted Pairs
Cabled Conductors

Aerial, Duct or Buried

Twisted Pairs

Cabled Conductors
Twisted Pairs
Cabled Conductors
Twisted Pairs
Cabled Conductors
Twisted Pairs
Single Hard-Drawn

Shielded
PVC Outer Jacket
Shielded
PE Inner &
PVC Outer Jackets
Shielded,
PE Inner &
PVC Outer Jackets
PE Outer Jacket
Shielded
PE Outer Jacket
PE Outer Jacket
Shielded
PE Outer Jacket
Shielded, PE Inner
& Outer Jacket
Shielded, PE Inner
& Outer Jacket
High Density Polyethylene
(HDPE)Insulation
HDPE Insulation
HDPE Insulation

HDPE Insulation

HDPE Insulation
PVC Outer Jacket
HDPE Insulation
PVC Outer Jacket
Shielded
PVC Outer Jacket

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

526
20140110

CONTROL CABLES

Aerial Self-Supporting Single Copper-Covered


Steel Conductor
Signal Systems
Aerial Self-Supporting C Line Wire (Parallel)
2 Hard-Drawn
Copper Conductors
Signal Systems
Aerial Self-Supporting C Line Wire (Parallel
2 Copper-Covered
Steel Conductors
Signal Systems
Aerial Self-Supporting C Line Wire (Parallel)
2 Hard-Drawn
Copper Conductors
Signal Systems
Aerial Self-Supporting C Line Wire (Parallel)
2 Copper-Covered
Steel Conductors
Fire Protective Signal
Aerial, Duct or
Twisted Pairs
Traffic Communications Building Raceway
Data Acquisition

Shielded
PVC Outer Jacket
PVC Outer Jacket

CONTROL CABLES

IMSA Cable
Selection Guide
Item #

IMSA
Spec No.

Voltage
Rating

39-4

39-4

300

39-6

39-6

300

40-2

40-2

300

40-4

40-4

300

40-6

40-6

300

50-2

50-2

600

51-1

51-1

51-3

Applications

Installation

Conductor
Configuration

Mechanical
Characteristics

Twisted Pairs

Shielded
PVC Outer Jacket
Shielded
PE Inner &
PVC Outer Jackets
Shielded
PE Outer Jacket

600

Traffic Communications
Figure-8 Aerial
Data Acquisition
Integral Msgr.
Fire Protective Signal
Aerial, Duct or
Traffic Communications Building Raceway
Data Acquisition
Fire Protective Signal
Aerial, Duct or
Traffic Communications Building Raceway
Data Acquisition
Traffic Communications
Figure-8 Aerial
Data Acquisition
Integral Msgr.
Fire Protective Signal Aerial, Duct, Buried or
Traffic Communications Building Raceway
Data Acquisition
Signal Loop Detector
Duct or Buried
Lead-In Feeder
Inductance Loop Detector
Duct

Single Conductor

51-3

600

Inductance Loop Detector

Duct or Buried

Single Conductor

51-5

51-5

600

Inductance Loop Detector

Duct or Buried

Single Conductor

51-7

51-7

600

Inductance Loop Detector

Duct or Buried

Single Conductor

59-2

59-2

300

Aerial or Duct

Twisted Pairs

59-4

59-4

300

Fire Protective Signal


Traffic Communications
Data Acquisition
Traffic Communications
Data Acquisition

Figure-8 Aerial
Integral Msgr.

Twisted Pairs

59-6

59-6

300

Fire Protective Signal


Traffic Communications
Data Acquisition

Aerial,
Duct or Buried

Twisted Pairs

60-2

60-2

300

Aerial or Duct

Twisted Pairs

60-4

60-4

300

Fire Protective Signal


Traffic Communications
Data Acquisition
Traffic Communications
Data Acquisition

Figure-8 Aeria
Integral Msgr.

Twisted Pairs

60-6

60-6

300

Fire Protective Signal


Traffic Communications
Data Acquisition

Aerial,
Duct or Buried

Twisted Pairs

70-1

70-1

Traffic Communications

2 to 72 fibers

70-5

70-5

Traffic Communications

Aerial,
Duct or Buried
Duct or Buried

Shielded
PE Outer Jacket
Shielded
PE Inner &
Outer Jacket
PE Insulation
PE Outer Jacket
PVC/Nylon
Insulation
Cross-Linked
PE Insulation
PVC/Nylon
Insulation in
PVC or PE Tube
Cross-Linked
PE Insulation in
PVC or PE Tube
Filled Core,
Shielded
PVC Outer Jacket
Filled Core,
Shielded
PVC Outer Jacket
Filled Core
Shielded
PE Inner Jacket
PVC Outer Jacket
Filled Core
Shielded
PE Outer Jacket
Filled Core
Shielded
PE Outer Jacket
Filled Core,
Shielded,
PE Inner and
PE Outer Jacket
All Dialectric

2 to 72 fibers

Armored

Twisted Pairs

Twisted Pairs

Twisted Pairs
Twisted Pairs

Twisted Pairs

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
526
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

IMSA Cable
Color Code Chart
Method 1
This color code system employs six (6) different base colors alternating through a series of 21 conductors. In this series, the last 15 conductors are marked with tracers of contrasting colors. The
color sequence is repeated in regular sequence as necessary for cable configurations employing
more than twenty-one (21) conductors.

Item #
IMSA-CC-1
IMSA-CC-2
IMSA-CC-3
IMSA-CC-4
IMSA-CC-5
IMSA-CC-6
IMSA-CC-7
IMSA-CC-8
IMSA-CC-9
IMSA-CC-10
IMSA-CC-11

Conductor
Number

Base
Color

Tracer
Color

Item #

1
2
3
4
5
6
7
8
9
10
11

Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue

N/A
N/A
N/A
N/A
N/A
N/A
Black
Black
Black
Black
Black

IMSA-CC-12
IMSA-CC-13
IMSA-CC-14
IMSA-CC-15
IMSA-CC-16
IMSA-CC-17
IMSA-CC-18
IMSA-CC-19
IMSA-CC-20
IMSA-CC-21

Conductor
Number

Base
Color

Tracer
Color

12
13
14
15
16
17
18
19
20
21

Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange

White
White
White
White
Red
Red
Red
Red
Green
Green

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

527
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

IMSA Cable
XHHX-2 & USE-2
Shipping Weights
XHHX-2 Shipping Weights
Item #

IMSA-X14
IMSA-X12
IMSA-X10
IMSA-X8
IMSA-X6
IMSA-X4
IMSA-X2
IMSA-X1

Size AWG

14
12
10
8
6
4
2
1

Weight
/MFT
(lb)
18
25
40
67
100
150
230
290

USE-2 Shipping Weights


Item #

IMSA-U14
IMSA-U12
IMSA-U10
IMSA-U8
IMSA-U6
IMSA-U4
IMSA-U2
IMSA-U1

Size AWG

14
12
10
8
6
4
2
1

Weight
/MFT
(lb)
23
30
43
72
106
157
237
304

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

528
20140110

CONTROL CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Methods of Color Coding
Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by different manufacturers.
The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for
ease and convenience, ink printed versions were developed.
Telephone requirements established special color codes.
Color Codes (ICEA Methods)
ICEA/NEMA Method 1
Colored insulation with contrasting ink tracers as required. Six
different insulation colors and four different colored ink tracers are used to provide positive identification through 21 conductors. The same identification sequence is repeated for
cables containing more than 21 conductors.
ICEA/NEMA Method 2
A neutral colored compound is used with single or double spiral ink tracers as required to provide positive identification
through 21 conductors. The identification sequence is repeated
for cables containing more than 21 conductors.
ICEA/NEMA Method 3
A neutral or single colored insulation compound is surface ink
printed with both conductor number and color designation to
provide positive identification through 21 conductors. The
identification sequence is repeated for colors containing more
than 21 conductors.
ICEA/NEMA Method 4
A neutral or single colored insulation compound is surface ink
printed with conductor number to provide positive conductor
identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

ICEA/NEMA Method 5
A color coding using braids. Also sometimes specified using
colored insulation and contrasting tracers as an extension of
Method I to eliminate duplicate conductors. Up to 127 positive
conductor coding are available with this method. Usually
specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table
5-2.
ICEA/NEMA Method 6
A color coding whereby one conductor in each layer is identified by a braid, tape, ridge, stripe or color.
ICEA/NEMA Paired Color Code
A coding whereby one leg of all pairs is coded white and its
mate is coded in accordance with the first 21 conductors of
Method 1, omitting white and repeating the sequence as necessary.
Telephone Paired Color Code
Five colors are paired with each of five mate colors to give 25
identified pairs. The color sequences are repeated for more
than 25 pairs using colored binder strings for group identification.

Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is
ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

B
20140110

Wire & Cable


Color Coding Charts
ICEA Method 1, Table E-1

ICEA Method 1, Table E-2

(Colored compound with tracers)

(Colored compound with tracers)

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Background
or Base Color
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange

Tracer
Color

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green

CONTROL CABLES

*This conductor is in the inside of the assembly.

ICEA Method 2, Table E-1


(Neutral colored compound with tracers)

Conductor
Number

1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

First
Tracer
Color
(Wide
Tracer)
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange

Second
Tracer
Color
(Narrow
Tracer)

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green

*This conductor is in the inside of the assembly.

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Background
or Base Color
Black
Red
Blue
Orange
Yellow
Brown
Red
Blue
Orange
Yellow
Brown
Black
Blue
Orange
Yellow
Brown
Black
Red
Orange
Yellow
Brown
Black
Red
Blue
Yellow
Brown
Black
Red
Blue
Orange
Brown
Black
Red
Blue
Orange
Yellow

Tracer
Color

Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Brown
Brown
Brown
Brown
Brown

*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable


Color Coding Charts
ICEA Method 1, Table E-2

ICEA Method 3

ICEA Method 4

(Neutral colored compound with tracers)

(Neutral or single color compound with surface


printing of numbers and color designations)

(Neutral or single color compound with surface


printing of numbers)

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Background
or Base Color
Black
Red
Blue
Orange
Yellow
Brown
Red
Blue
Orange
Yellow
Brown
Black
Blue
Orange
Yellow
Brown
Black
Red
Orange
Yellow
Brown
Black
Red
Blue
Yellow
Brown
Black
Red
Blue
Orange
Brown
Black
Red
Blue
Orange
Yellow

Tracer
Color
Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Brown
Brown
Brown
Brown
Brown

Printed Legend
1 Black
2 White
3 Red
4 Green
5 Orange
6 Blue
7 WhiteBlack
8 RedBlack
9 GreenBlack
10 OrangeBlack
11 BlueBlack
12 BlackWhite
13 RedWhite
14 GreenWhite
15 BlueWhite
16 BlackRed
17 WhiteRed
18 OrangeRed
19 BlueRed
20 RedGreen
21 OrangeGreen

*This conductor is in the inside of the assembly.

Printed Legend
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

*This conductor is in the inside of the assembly.

CONTROL CABLES

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

B
20140110

Wire & Cable


Color Coding Charts
ICEA Method 5
(Colored compounds with tracers)

CONTROL CABLES

Cond.
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Background
or
Base Color
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange
Black
White
Orange
Blue
Red
Orange
Black
White
Red
Green
Orange
Blue
Black
White
Orange
White
Black
White
Red
Green
Orange
Blue

First
Tracer
Color

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green
White
Black
Black
Black
Black
Black
Red
Red
Black
Black
Black
White
White
Red
White
Red
White
Black
White
White
Red
Red

Second
Tracer
Color

Red
Red
White
White
White
White
Green
Green
Green
Orange
Green
Orange
Orange
Orange
Blue
Blue
Green
Green
Green
Blue
Green
Green

Cond.
Number
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86

Background
or
Base Color
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
Red
Green
Orange
Blue
Red
Green
Blue
Orange
Green
Black
White
Blue

First
Tracer
Color
White
Black
White
Orange
Red
Red
Orange
Black
Orange
Red
Black
Black
Orange
Orange
Orange
Black
Green
Green
Red
Orange
Black
Orange
White
White
Green
Green
Green
White
Red
Red
Orange
Orange
Red
White
White
White
White
Black
White
Red
Green
Green
Green

Second
Tracer
Color
Blue
Blue
Blue
Red
Blue
Orange
Red
Orange
Black
Blue
Blue
Orange
Green
Green
Green
Blue
Blue
Orange
Blue
Blue
Blue
Blue
Red
Red
Blue
Blue
Blue
Red
Black
Black
Blue
Blue
Black
Green
Green
Orange
Orange
Green

Cond.
Number
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

Background
or
Base Color
Black
White
Red
Green
Blue
Black
White
Red
Green
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Black
White
Red
Green
Orange
Blue
Black
White
Green
Orange
Blue
Black
Red
Green
Orange
Blue
Black
White
Red
Orange
Blue
Black
White
Red

First
Tracer
Color
Orange
Orange
Orange
Orange
Orange
Blue
Blue
Blue
Blue
Blue

Black
White
Red
Green
Orange
Blue
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow

Second
Tracer
Color

Red
Red
Red
Red
Red
White
White
White
White
White
Green
Green
Green
Green
Green
Blue
Blue
Blue

*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

FIBER OPTIC CABLES


Table of Contents
OPGW Optical Ground Wire..................................................................................................607
Installation Manual for OPGW Cable ...................................................................................608
OPGW Cable & System Information Guide for Hardware Selection .................................602
ADSS Fiber Optic Cable ........................................................................................................603
Loose Tube Fiber Optic Cable................................................................................................604
Loose Tube Fiber Optic Cable for Direct Burial....................................................................606
HDPE Conduit.........................................................................................................................605

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

600
20150407

FIBER OPTIC CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

OPGW Optical Ground Wire


Applications
OPGW cable is suited for installation on transmission lines with the double function of a ground wire
(designed to replace traditional static or shield wires) and a communication wire. OPGW conducts
short circuit current and provide lightning resistance as it shields conductors, while providing a
telecommunications path for internal as well as third party communications. OPGW must be capable
of withstanding the mechanical and environmental stresses inflicted on overhead cables (such those
caused by wind or ice). OPGW must also be capable of handling electrical faults on the transmission
line by providing a path to ground yet preventing damage to the delicate optical fibers inside the cable.
OPGW (Optical Ground Wire) with a stainless steel central tube is preferred for its compact size and
ability to house up to 72 fibers in a diameter starting at only 12mm. Its small profile offers an exceptional solution to the diameter and weight concerns on many of todays overloaded transmission
towers where an existing shield wire needs to be replaced with an OPGW cable.
Construction
OPGW cable has two constructions:
Central loose tube type:The fibers are placed loosely in a sealed and water resistant central, aluminum tube filled with water blocking gel. This tube provides protection to the fiber during installation and operation under severe environmental conditions. The stainless steel tube may also be
aluminum-clad steel depending on the engineering requirements. The stainless optical tube is located at the center of the cable protected by single or multiple layers of aluminum clad steel, aluminum alloy wires, or steel wires. The metallic wires provide mechanical strength to withstand
severe installation and operating conditions, while achieving conductivity to control temperature
rise during short circuit conditions.
Each optical fiber is clearly distinguishable utilizing a fiber identification system consisting of coloring and the number of ring marks on it. This compact design features high mechanical strength and
fault current rating within a smaller diameter. The smaller diameter also results in excellent sag tension performance.
Multi loose tube type: The fibers is placed loosely in a sealed and water resistant stainless steel
tube filled with water blocking gel. Two or three stainless steel optical tubes are helically stranded in
the inner layer of a multiple-layer cable. The multi loose tube type is designed mostly for very high
fiber count requirement over 48 with the maximum fiber count reaching 144. The multi loose tube
type can meet the requirement of huge cross and large current capacity.
The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber primary protective coating. The detail data of optical fiber performance are shown in the following table.
Optical fiber uses special spun device successfully controlled the value of PMD, and makes sure
that it can keep stable in cabling.
IEC 61232 Aluminum clad steel wire for electrical purposes
IEC 60104 Aluminum magnesium-silicon alloy
wire for overhead line conductors
IEC 61089 Round wire concentric lay overhead
electrical stranded conductors
Fiber is Corning SMF-28e+ Optical Fiber
Options
Hardware for Installation
Notes
Reel lengths must be defined at time of purchase to assist client with reducing waste, and
to reduce splicing required during installation.
Please contact AWG for full detailed technical
specifications, including PLS CADD data or
Stress Creep data.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

607
20150407

FIBER OPTIC CABLES

Standards
IEC 60793-1 Optical fiber Part 1: Generic specifications
IEC 60793-2 Optical fiber Part 2: Product specifications
ITU-T G.652 Characteristics of a single-mode
optical fiber cable
ITU-T G.655 Characteristics of a non-zero dispersion-shifted single-mode optical fiber and
Cable
EIA/TIA 598 Color code of fiber optic cables
IEC 60794-4-10 Aerial optical cables along
electrical power lines Family specification
for OPGW
IEC 60794-1-2 Optical fiber cables-Part 1-2:
Generic specification - Basic optical cable test
procedures
IEEE1138-2009 IEEE Standard for testing and
performance for optical ground wire (OPGW)
for use on electric utility power lines

OPGW Optical Ground Wire


Item #

Fibers

Total
Conductor
Area
(in2)

Total
Conductor
Area
(mm2)

Overall
Diameter
(in)

Overall
Diameter
(mm)

Weight
(lb/ft)

Weight
(kg/km)

RBS
(lb)

RBS
(kb)

51

0.1273

85.05

0.484

12.3

0.321

0.478

17390

7888

46

0.1202

80.34

0.484

12.3

0.313

0.466

16107

7306

97

0.1603

107.13

0.544

13.8

0.338

0.503

16984

7704

121

0.1722

115.05

0.563

14.3

0.328

0.488

15611

7081

147

0.2046

136.72

0.630

16

0.472

0.702

24048

10908

154

0.2046

136.72

0.630

16

0.450

0.67

22384

10153

186

0.2246

150.11

0.662

16.8

0.499

0.742

24183

10969

134

0.1926

128.68

0.630

16

0.449

0.668

21865

9918

134

0.1926

128.68

0.630

16

0.449

0.668

21934

9949

161

0.2114

141.29

0.662

16.8

0.499

0.743

23598

10704

FIBER OPTIC CABLES

SINGLE STAINLESS STEEL TUBE


OPGW-2S1/24
(M85/R77-51)
24
OPGW-2S2/18
(M80/R72-46)
36
OPGW-2S1/24
(M107/R76-97)
24
OPGW-2S1/24
(M115/R69-121)
24
OPGW-2S42/48
(M137/R107-147)
96
OPGW-2S2/48
(M137/R100-154)
96
OPGW-2S2/48
(M150/R107-186)
96
OPGW-2S3/48
(M129/R97-134)
144
OPGW-2S3/48
(M129/R98-134)
144
OPGW-2S3/48
(M141/R105-161)
144

Fault
Current
(KA2sec)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
607
20150407

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

OPGW Optical Ground Wire


Item #

Fault
Current
(KA2sec)

Total
Conductor
Area
(in2)

Total
Conductor
Area
(mm2)

Overall
Diameter
(in)

Overall
Diameter
(mm)

Weight
(lb/ft)

Weight
(kg/km)

RBS
(lb)

RBS
(kb)

43

0.1195

79.88

0.496

12.6

0.300

0.447

16197

7347

63

0.1195

79.88

0.516

13.1

0.272

0.404

11338

5143

88

0.1694

113.19

0.571

14.5

0.421

0.626

22902

10388

101

0.1694

113.19

0.571

14.5

0.369

0.549

15410

6990

12

43

0.1195

79.88

0.496

12.6

0.301

0.448

16219

7357

12

63

0.1195

79.88

0.516

13.1

0.272

0.404

11338

5143

12

67

0.1494

99.86

0.544

13.8

0.376

0.56

20426

9265

12

78

0.1461

97.62

0.544

13.8

0.329

0.49

13790

6255

24

69

0.1481

98.96

0.540

13.7

0.362

0.538

19257

8735

24

83

0.1481

98.96

0.540

13.7

0.298

0.443

12350

5602

24

83

0.1622

108.39

0.559

14.2

0.393

0.585

21147

9592

24

101

0.1622

108.39

0.559

14.2

0.323

0.481

13565

6153

36

98

0.1741

116.36

0.595

15.1

0.417

0.621

21619

9806

36

111

0.1741

116.36

0.595

15.1

0.368

0.548

14758

6694

36

124

0.1978

132.14

0.626

15.9

0.478

0.712

25150

11408

36

141

0.1978

132.14

0.626

15.9

0.422

0.628

17119

7765

48

153

0.2148

143.52

0.646

16.4

0.499

0.742

25510

11571

48

179

0.2196

146.73

0.650

16.5

0.454

0.676

18087

8204

48

253

0.2814

188

0.725

18.4

0.673

1.001

35139

15939

48

305

0.2814

188

0.725

18.4

0.555

0.826

22699

10296

72

159

0.2178

145.55

0.677

17.2

0.504

0.75

25556

11592

72

184

0.2206

147.41

0.677

17.2

0.435

0.648

17727

8041

72

188

0.2394

160

0.701

17.8

0.569

0.846

29672

13459

72

213

0.2394

160

0.701

17.8

0.503

0.749

20585

9337

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

607
20150407

FIBER OPTIC CABLES

ALUMINUM TUBE
OPGW(LAL_Tube)-1S8
(M80/R72-43)
OPGW(LAL_Tube)-1S8
(M87/R50-63)
OPGW(LAL_Tube)-1S8
(M113/R102-88)
OPGW(LAL_Tube)-1S8
(M113/R69-101)
OPGW(LAL_Tube)-1S12
(M80/R72-43)
OPGW(LAL_Tube)-1S12
(M87/R50-63)
OPGW(L-AL_Tube)-1S12
(M100/R91-67)
OPGW(LAL_Tube)-1S12
(M100/R61-78)
OPGW(LAL_Tube)-1S24
(M99/R86-69)
OPGW(LAL_Tube)-1S24
(M99/R55-83)
OPGW(LAL_Tube)-1S24
(M108/R94-83)
OPGW(LAL_Tube)-1S24
(M108/R60-101)
OPGW(LAL_Tube)-1S36
(M116/R96-98)
OPGW(LAL_Tube)-1S36
(M116/R66-111)
OPGW(LAL_Tube)-1S36
(M132/R112-124)
OPGW(LAL_Tube)-1S36
(M132/R76-141)
OPGW(LAL_Tube)-1S48
(M144/R113-153)
OPGW(LAL_Tube)-1S48
(M147/R80-179)
OPGW(LAL_Tube)-1S48
(M188/R156-253)
OPGW(LAL_Tube)-1S48
(M188/R101-305)
OPGW(LAL_Tube)-1S72
(M146/R114-159)
OPGW(LAL_Tube)-1S72
(M146/R79-184)
OPGW(LAL_Tube)-1S72
(M160/R132-188)
OPGW(LAL_Tube)-1S72
(M160/R92-213)

Fibers

OPGW Optical Ground Wire


Item #

Fibers

Total
Conductor
Area
(in2)

Total
Conductor
Area
(mm2)

Overall
Diameter
(in)

Overall
Diameter
(mm)

Weight
(lb/ft)

Weight
(kg/km)

RBS
(lb)

RBS
(kb)

44

0.1218

81.39

0.469

11.9

0.316

0.47

17075

7745

55

0.1218

81.39

0.469

11.9

0.259

0.385

10820

4908

55

0.1330

88.87

0.488

12.4

0.327

0.487

16850

7643

66

0.1330

88.87

0.488

12.4

0.280

0.416

11541

5235

64

0.1430

95.56

0.504

12.8

0.351

0.522

18470

8378

76

0.1430

95.56

0.504

12.8

0.299

0.445

12644

5735

66

0.1481

98.99

0.512

13

0.378

0.562

20831

9449

76

0.1481

98.99

0.512

13

0.331

0.493

14174

6429

76

0.1586

106.01

0.528

13.4

0.403

0.599

22024

9990

94

0.1586

106.01

0.528

13.4

0.330

0.491

14105

6398

FIBER OPTIC CABLES

ALUMINUM CLAD STEEL TUBE


OPGW(ALTube)-1S48
(M81/R76-44)
48
OPGW(ALTube)-1S48
(M81/R48-55)
48
OPGW(ALTube)-1S48
(M89/R75-55)
48
OPGW(ALTube)-1S48
(M89/R51-66)
48
OPGW(ALTube)-1S48
(M96/R82-64)
48
OPGW(AL-Tube)-1S48
(M96/R56-76)
48
OPGW(ALTube)-1S48
(M99/R93-66)
48
OPGW(ALTube)-1S48
(M99/R63-76)
48
OPGW(ALTube)-1S48
(M106/R98-76)
48
OPGW(ALTube)-1S48
(M106/R63-94)
48

Fault
Current
(KA2sec)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
607
20150407

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

OPGW Optical Ground Wire


Designation

Fiber
Count
(max)

Fault
Duty
(kA2s)

RBS
(lb)

Weight
(lb/ft)

Area
(in2)

Sag10
Chart

0.528
0.528
0.472
0.472
0.512
0.528
0.531
0.534
0.555
0.528
0.555
0.555
0.571
0.571
0.472
0.472
0.472
0.602
0.602
0.606
0.646
0.646
0.472
0.472
0.528
0.472
0.506
0.528
0.531
0.591
0.506
0.602
0.620
0.646
0.646
0.646
0.785
0.836

74.8
71.9
46.3
48.1
75.1
68.9
74.1
88.0
84.5
71.9
91.7
103.9
109.8
116.2
41.9
49.4
28.8
118.0
123.1
153.9
190.1
179.7
37.7
39.2
71.9
43.3
62.9
65.1
67.0
106.4
54.4
104.9
146.6
167.8
172.4
155.9
426.6
498.6

19,468
20,620
16,536
15,613
13,987
21,771
20,928
15,529
24,105
20,620
21,555
16,455
20,098
17,402
15,310
10,692
20,851
26,909
25,716
17,073
21,902
25,249
14,083
13,159
20,620
10,389
12,292
19,090
19,376
22,478
11,915
24,642
18,418
21,336
19,662
24,617
19,735
23,121

0.365
0.380
0.305
0.293
0.286
0.395
0.386
0.316
0.438
0.380
0.404
0.337
0.391
0.356
0.293
0.232
0.366
0.502
0.479
0.368
0.454
0.499
0.281
0.269
0.380
0.232
0.267
0.365
0.370
0.435
0.267
0.476
0.397
0.451
0.428
0.517
0.504
0.599

0.16
0.16
0.13
0.13
0.15
0.16
0.16
0.16
0.17
0.16
0.17
0.17
0.18
0.18
0.12
0.12
0.12
0.20
0.20
0.21
0.24
0.24
0.11
0.11
0.16
0.11
0.13
0.15
0.15
0.19
0.13
0.19
0.21
0.22
0.22
0.22
0.34
0.37

1-1461
1-1457
1-1457
1-1461
1-1455
1-1427
1-1457
1-1170
1-1427
1-1457
1-1461
1-1455
1-536
1-1455
1-1450
1-1439
1-1140
1-1453
1-1450
1-1441
1-1455
1-536
1-1461
1-1444
1-1457
1-1439
1-1439
1-1450
1-1450
1-1461
1-1455
1-1457
1-1439
1-1170
1-1439
1-1427
1-1056
1-1056

Notes:
*Many other designs are also available.
*Specifications are subject to change without notice.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

607
20150407

FIBER OPTIC CABLES

MULTI STAINLESS STEEL TUBE


39AY68ACS-1C-1
12
39AY68ACS-1C-2
12
27AY59ACS-1C
16
32AY54ACS-1C
16
64AY37ACS-1C
20
34AY73ACS-1C
24
34AY74ACS-1C
24
68AY42ACS-1C
24
31AY87ACS-1C
24
39AY68ACS-1C-3
24
44AY75ACS-1C
24
75AY44ACS-1C
24
59AY66ACS-1C
24
79AY46ACS-1C
24
27AY59ACS-2C
32
59AY27ACS-2C
32
86ACS-2C
32
40AY100ACS-1C
36
56AY83ACS-1C
36
103AY40ACS-1C
36
101AY59ACS-1C
36
84AY76ACS-1C
36
27AY59ACS-3C
48
32AY54ACS-3C
48
39AY68ACS-1C-4
48
59AY27ACS-3C
48
67AY32ACS-2C
48
34AY73ACS-2C
48
34AY74ACS-2C
48
49AY85ACS-2C
48
67AY32ACS-3C
72
40AY100ACS-2C
72
101AY47ACS-2C
72
101AY59ACS-2C
72
110AY51ACS-2C
72
59AY101ACS(27)-2C 72
191AY45ACS-3C
72
194AY74ACS-3C
144

Diameter
(in)

FIBER OPTIC CABLES

Notes

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Installation Manual for OPGW Cable


This handbook is formulated on IEEE 1138-2008 and IEEE 524-1992 etc.
OPGW has two functions: electric aerial ground wire and fiber communication.
It is constituted of AS wire, AA wire and stainless steel tube op-unit. The installation rules of OPGW
are almost the same as the engineering and installation modes of traditional aerial electric power
wire, referring to electric power company's aerial transmit circuitry installation skills, management
and other related files. In order to guarantee the installation of OPGW and avoid the waste of personnel and material resources, we compile this handbook as the reference, not instead of any other
manufacturers' installation instructions.
OPGW is usually installed on the top of pole of the electric power aerial wire. The following disadvantages should be considered: vibration caused by wind, hurricane, ice thickness, unsteady operation caused by temperature, and possible thunder attack, short circuit ere. Therefore, detailed
engineering program should be formulated according to different structures of OPGW and specific
route conditions. According to design requirement, OPGW should be allotted correctly; every tray of
optical fiber cable should he installed in the appointed part of route and should be laid according to
engineering chart operation file.
Please click HERE to download the complete intallation manual.

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

608
20150407

FIBER OPTIC CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

OPGW Cable & System Information Guide


for Hardware Selection
The following outline describes the OPGW cable information required to select proper cable attachment hardware and accessories. Most of the cable information can be found in the cable specification it is recommended that this information be gathered along with the information about the
cable system. Submit this information to American Wire Group to verify proper application.
A. CABLE INFORMATION REQUIRED for DEAD-ENDS AND SUSPENSIONS
1. CABLE SPECIFICATIONS/Cable Specification Sheet Data
a. Cable Diameter: Overall outer diameter of the OPGW.
b. Cable Construction Strand Configuration: Lay Direction of outer wire strands, Distribution
and Location of individual strand materials in a cross-section, Number of strand layers.
c. Rated Breaking Strength
d. Fault Current
2. CABLE SYSTEM
a. Maximum Vertical Load at Hardware Attachment
b. Line Angles
In addition to the outline above, other products offered for OPGW applications require further information as listed in Part B below.
B. ADDITIONAL INFORMATION FOR OTHER HARDWARE ACCESSORIES
1. Splice Closures, Closures, and Domes
a. Fiber Count
b. Fiber Type
c. Fiber Optic Element Configuration
d. Type of Buffer Tubes (plastic or stainless steel)
e. Core construction (Solid, Aluminum Tube, Aluminum Channel),
2. Spiral Vibration Damper
a. Span Lengths
b. Final Tension at the Average Annual Minimum Temperature (AAMT)
c. Terrain
3. FITTINGS (Y-Clevis, Clevis Eye, Yoke Plates), Ground Wire, Downlead Cushions, Cable Storage
a. Interface at structure
b. Type of Structure (Wood Pole, Concrete, Steel, Lattice Tower)
c. Ground Wire Material, Bonding Material
HARDWARE TESTS
The IEEE 1138 Test Standard for OPGW includes a series of tests that require suitable hardware to
demonstrate system performance. System tests include Tensile Strength, Vibration Test, and Galloping Tests among others. System tests require dead-ends and suspensions that can survive the test
parameters and prove cable/hardware compatibility.

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

602
20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

ADSS
All Dielectric Self-Supporting
Fiber Optic Cable
Applications
The All Dielectric Self-Supporting (ADSS) cables are designed for aerial self-supporting applications at short, medium and long span distances. ADSS cables offer a rapid and economical means
for deploying optical fiber cables along existing aerial rights-of-way. They are being deployed by
cable television operators, telephone companies, municipalities and emerging network operators,
in addition to electric power utilities.
Construction
The ADSS cable consists of a number of tubes/elements according to the specified number of
fibers. The elements are usually fiber-containing tubes; however fillers may be used to preserve the
cable geometry. Two to twelve color-coded fibers are loosely laid in each tube which is filled with a
water-blocking gel. The tubes are stranded around a dielectric central strength member and bound
in a jacket. A water-swelling tape is helically wrapped around the cable core. Aramid yarn strength
members are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly
bound over the aramid yarn layer. For long span applications a double jacket design can be considered. A ripcord is located under each jacket layer to facilitate its removal. For up to 30 fiber cables,
the ADSB design is applicable, for 32-144 fibers the ADSC design is applicable. Dry cable designs, ballistic protection and other cable designs are available upon request..
Standards
Cables are designed for aerial installation according to IEEE-P1 222
Cables tested according to TIA/EIA-455 and IEC-60794-1.
Cables meet or exceed Telcordia (Bellcore) requirements for outside plant cables (GR-20) when the
appropriate options are chosen.
Default Jacket Colors
PE HFFR SM Fibers Black Yellow MM Fibers Black Orange
Other jacket colors may be available, please specify.
Sag Chart
Below are the coefficients for a standard ADSS cable containing 32 to 60 fibers in 5 tubes with a single outer jacket. The cable can be used in a span of 450 feet with NESC light conditions, 300 feet for
NESC medium and 240 feet for NESC heavy conditions.
Cross section area 0.196 in^2
Outside diameter 0.5 in
Unit weight 0.081 lbs/ft
Ultimate tension 5800 lbs
The following values are calculated at 68F
Final modulus of elasticity 3248850 psi
Thermal expansion coefficient -2.78e-7F
Stress strain A1 2973280 psi
Creep A1 2625190 psi

Item #

Number of
Elements

2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
2-30 ADSB
32-60 ADSC
32-60 ADSC

5
5
5
5
5
5
5
5
5
5
5

Cable
Weight
(kg/km)
105
105
105
105
105
105
105
105
105
120
120

Cable Installation
Diameter Tension
(mm)
(N)(2)
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
12.7
12.7

400
525
800
860
985
1255
1520
1785
1920
425
570

Span
(m)
(m)

Sag in
Light
(m)

Tension
in Light
(N)

Sag in
Medium
(m)

Tension
in Medium
(N)

Sag in
Heavy
(m)

Tension
in Heavy
(N)

30
40
60
70
80
100
120
135
150
30
40

0.16
0.22
0.37
0.46
0.54
0.71
0.89
1.01
1.16
0.16
0.23

1230
1540
2100
2300
2560
3040
3500
3870
4170
1310
1630

0.48
0.69
1.16
1.42
1.68
2.25
2.80
3.23
3.70
0.49
0.71

1600
1970
2650
2930
3240
3820
4380
4810
5180
1650
2030

0.66
0.95
1.6
2.27
2.33

0.67
0.96

2370
2940
3900
4320
4755

2430
3000

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

603
20140110

FIBER OPTIC CABLES

ADSS-1
ADSS-2
ADSS-3
ADSS-4
ADSS-5
ADSS-6
ADSS-7
ADSS-8
ADSS-9
ADSS-10
ADSS-11

ADS
Series

ADSS
All Dielectric Self-Supporting
Fiber Optic Cable

FIBER OPTIC CABLES

Item #

ADSS-12
ADSS-13
ADSS-14
ADSS-15
ADSS-16
ADSS-17
ADSS-18
ADSS-19
ADSS-20
ADSS-21
ADSS-22
ADSS-23
ADSS-24
ADSS-25
ADSS-26
ADSS-27
ADSS-28
ADSS-29
ADSS-30
ADSS-31
ADSS-32
ADSS-33
ADSS-34
ADSS-35
ADSS-36
ADSS-37
ADSS-38
ADSS-39
ADSS-40
ADSS-41
ADSS-42
ADSS-43
ADSS-44
ADSS-45
ADSS-46
ADSS-47
ADSS-48
ADSS-49
ADSS-50
ADSS-51
ADSS-52
ADSS-53

ADS
Series

Number of
Elements

32-60 ADSC
32-60 ADSC
32-60 ADSC
32-60 ADSC
32-60 ADSC
32-60 ADSC
32-60 ADSC
32-60 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
62-72 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
74-96 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
98-126 ADSC
122-144 ADSC
122-144 ADSC
122-144 ADSC
122-144 ADSC
122-144 ADSC
122-144 ADSC
122-144 ADSC

5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12

Cable
Weight
(kg/km)
120
120
120
120
120
120
120
120
125
125
125
125
125
125
125
125
125
125
180
180
180
180
180
180
180
180
180
220
220
220
220
220
220
220
220
280
280
280
280
280
280
280

Cable Installation
Diameter Tension
(mm)
(N)(2)
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
14.2
14.2
14.2
14.2
14.2
14.2
14.2
14.2
14.2
16
16
16
16
16
16
16
16
17.2
17.2
17.2
17.2
17.2
17.2
17.2

715
845
990
1120
1500
1780
1936
2200
443
580
795
950
1085
1240
1530
180
2080
2340
580
820
1000
1220
1400
1640
1960
2360
2640
834
1100
1290
1590
1860
2150
2690
3250
1030
1340
1720
2030
2440
2750
3470

Span
(m)
(m)

Sag in
Light
(m)

Tension
in Light
(N)

Sag in
Medium
(m)

Tension
in Medium
(N)

Sag in
Heavy
(m)

Tension
in Heavy
(N)

50
60
70
80
100
120
135
150
30
40
50
60
70
80
100
120
135
150
30
40
50
60
70
80
100
120
135
30
40
50
60
70
80
100
120
30
40
50
60
70
80
100

0.30
0.38
0.45
0.54
0.70
0.88
1.02
1.16
0.16
0.24
0.30
0.38
0.46
0.54
0.72
0.90
1.04
1.18
0.17
0.24
0.32
0.4
0.49
0.57
0.76
0.94
1.09
0.19
0.27
0.35
0.44
0.53
0.62
0.81
1.00
0.21
0.29
0.37
0.47
0.56
0.65
0.85

1940
2220
2520
2780
3340
3840
4150
4530
1320
1640
2000
2300
2570
2850
3350
3830
4220
4600
1500
1890
2220
2600
2890
3240
3790
4390
4800
1730
2150
2500
2910
3290
3680
4400
5114
1910
2380
2900
3300
3800
4215
5070

0.94
1.17
1.43
1.69
2.22
2.79
3.26

0.50
0.71
0.92
1.16
1.42
1.68
2.22
2.80
3.23

0.5
0.7
0.94
1.17
1.42
1.67
2.23

0.49
0.70
0.93
1.17
1.40
1.66
2.17

0.49
0.71
0.91
1.15
1.38
1.62

2400
2750
3080
3390
4050
4628
5020

1640
2040
2470
2800
3130
3450
4070
4650
5100

1800
2260
2630
3060
3415
3800
4450

2015
2500
2920
3360
3800
4215
5030

2200
2710
3280
3740
4270
4725

1.28
1.62
1.97
2.35

0.67
0.97
1.26
1.60
1.96
2.32

0.67
0.96
1.28
1.61
1.97

0.66
0.94
1.27
1.61
1.94

0.66
0.95
1.25
1.58

3530
4020
4500
4990

2500
3000
3590
4080
4540
5000

2590
3220
3770
4330
4820

2810
3500
4070
4660
5220

3030
3720
4400
5030

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
603
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Loose Tube Fiber Optic Cable


Applications
Multi-purpose Outdoor Aerial Lashed, Duct, Direct Buried
Constructions
Dielectric, Armored, Double Armored
Fiber Count
2 to 432 fibers in Color-coded Buffer Tubes
Fiber Types
Singlemode / Multimode
Options
Gel-Filled Core / Steel Central Member / Copper Pair(s)
Other versions
Central / Heavy Duty / Indoor-Outdoor
Performance
ANSI/ICEA, IEC, RUS, Telcordia GR-20
Mechanical Specifications
Installation
[+] Maximum installation load 600 lbf (2670 N)
[+] Maximum operation load 180 lbf (800 N)
Temperature Range
[+] Shipping and Storage -40F to +167F (-40C to +75C)
[+] Installation -22F to +140F (-30C to +60C)
[+] Operation -40F to +158F (-40C to +70C)

Item #

Fiber
Count

Dielectric (Non-Armored)
LT-DNA-1
2 to 60
LT-DNA-2
62 to 72
LT-DNA-3
74 to 84
LT-DNA-4
86 to 96
LT-DNA-5
98 to 108
LT-DNA-6
110 to 120
LT-DNA-7
122 to 132
LT-DNA-8
134 to 216
LT-DNA-9
218 to 264
LT-DNA-10
266 to 288
LT-DNA-11
290 to 432*

Number of
Buffer
Tubes

Diameter
(in)

Diameter
(mm)

5
6
7
8
9
10
11
18
22
24
18

0.42
0.45
0.49
0.53
0.56
0.60
0.63
0.67
0.74
0.77
0.73

10.6
11.5
12.3
13.4
14.2
15.1
16.1
16.9
18.9
19.6
18.6

Approximate Approximate
Cable
Cable
Weight
Weight
/MFT
/km
(lb)
(kg)
53
63
72
82
90
99
109
126
153
167
153

79
94
107
122
134
147
162
187
228
248
228

Bend
Radius
Load
(in)

Bend
Radius
Load
(cm)

Bend
Radius
No Load
(in)

Bend
Radius
No Load
(cm)

8
9
10
11
11
12
13
13
15
15
15

21
23
25
27
28
30
32
34
38
39
37

4
5
5
5
6
6
6
7
7
8
7

11
11
12
13
14
15
16
17
19
20
19
FIBER OPTIC CABLES

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.
Rated buffer storage length is 8 feet (2.4 meters)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

604
20140110

Loose Tube Fiber Optic Cable


Item #

Fiber
Count

Number of
Buffer
Tubes

FIBER OPTIC CABLES

Single Jacket Armored


LT-SJA-1
2 to 60
5
LT-SJA-2
62 to 72
6
LT-SJA-3
74 to 84
7
LT-SJA-4
86 to 96
8
LT-SJA-5
98 to 108
9
LT-SJA-6
110 to 120
10
LT-SJA-7
122 to 132
11
LT-SJA-8
134 to 216
18
LT-SJA-9
218 to 264
22
LT-SJA-10
266 to 288
24
LT-SJA-11
290 to 432*
18
Double Jacket Armored
LT-DJA-1
2 to 60
5
LT-DJA-2
62 to 72
6
LT-DJA-3
74 to 84
7
LT-DJA-4
86 to 96
8
LT-DJA-5
98 to 108
9
LT-DJA-6
110 to 120
10
LT-DJA-7
122 to 132
11
LT-DJA-8
134 to 216
18
LT-DJA-9
218 to 264
22
LT-DJA-10
266 to 288
24
LT-DJA-11
290 to 432*
18
Dielectric Double Jacket (Non-Armored)
LT-DDJ-1
2 to 60
5
LT-DDJ-2
62 to 72
6
LT-DDJ-3
74 to 84
7
LT-DDJ-4
86 to 96
8
LT-DDJ-5
98 to 108
9
LT-DDJ-6
110 to 120
10
LT-DDJ-7
122 to 132
11
LT-DDJ-8
134 to 216
18
LT-DDJ-9
218 to 264
22
LT-DDJ-10
266 to 288
24
LT-DDJ-11
290 to 432*
18

Diameter
(in)

Diameter
(mm)

Approximate Approximate
Cable
Cable
Weight
Weight
/MFT
/km
(lb)
(kg)

Bend
Radius
Load
(in)

Bend
Radius
Load
(cm)

Bend
Radius
No Load
(in)

Bend
Radius
No Load
(cm)

0.48
0.51
0.55
0.59
0.62
0.66
0.69
0.73
0.81
0.84
0.80

12.2
13.0
14.0
15.0
15.8
16.8
17.6
18.6
20.6
21.4
20.3

98
109
122
135
146
161
171
195
231
242
225

146
162
182
201
218
240
255
291
344
360
225

10
10
11
12
12
13
14
15
16
17
16

24
26
28
30
32
34
35
37
41
43
41

7
8
8
9
9
10
10
11
12
13
12

18
20
21
23
24
25
26
28
31
32
31

0.54
0.57
0.61
0.65
0.68
0.72
0.75
0.79
0.87
0.90
0.87

13.8
14.5
15.5
16.6
17.3
18.3
19.1
20.1
22.1
22.9
22.1

118
138
153
170
182
201
212
239
283
295
279

175
205
228
253
272
300
315
356
421
439
415

11
11
12
13
14
14
15
16
17
18
17

28
29
31
33
35
37
38
40
44
46
44

8
9
9
10
10
11
11
12
13
14
13

21
22
23
25
26
28
29
30
33
34
33

0.48
0.51
0.55
0.59
0.62
0.66
0.69
0.73
0.80
0.83
0.79

12.1
13.0
13.9
15.0
15.7
16.7
17.6
18.4
20.4
21.2
20.1

68
83
91
103
111
123
132
149
184
192
182

101
124
136
153
165
182
196
221
274
286
271

10
10
11
12
12
13
14
15
16
17
16

24
26
28
30
31
33
35
37
41
42
41

5
5
5
6
6
7
7
7
8
8
8

12
13
14
15
16
17
18
18
20
21
20

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.
Rated buffer storage length is 8 feet (2.4 meters)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
604
20140110

Informatio on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Loose Tube Fiber Optic Cable


Item #

Fiber
Count

Double Jacket Double Armored


LT-DJDA-1
2 to 60
LT-DJDA-2
62 to 72
LT-DJDA-3
74 to 84
LT-DJDA-4
86 to 96
LT-DJDA-5
98 to 108
LT-DJDA-6
110 to 120
LT-DJDA-7
122 to 132
LT-DJDA-8
134 to 216
LT-DJDA-9
218 to 264
LT-DJDA-10 266 to 288
LT-DJDA-11 290 to 432*
Triple Jacket Double Armored
LT-TJDA-1
2 to 60
LT-TJDA-2
62 to 72
LT-TJDA-3
74 to 84
LT-TJDA-4
86 to 96
LT-TJDA-5
98 to 108
LT-TJDA-6
110 to 120
LT-TJDA-7
122 to 132
LT-TJDA-8
134 to 216
LT-TJDA-9
218 to 264
LT-TJDA-10 266 to 288
LT-TJDA-11 290 to 432*

Number of
Buffer
Tubes

Diameter
(in)

Diameter
(mm)

Approximate Approximate
Cable
Cable
Weight
Weight
/MFT
/km
(lb)
(kg)

5
6
7
8
9
10
11
18
22
24
18

0.67
0.70
0.74
0.78
0.81
0.85
0.88
0.92
1.00
1.03
1.01

17.1
17.8
18.8
19.9
20.6
21.6
22.4
23.4
25.5
26.2
25.7

205
232
253
274
288
315
330
359
414
429
416

5
6
7
8
9
10
11
18
22
24
18

0.73
0.76
0.80
0.84
0.87
0.91
0.94
0.98
1.06
1.09
1.08

18.6
19.4
20.4
21.4
22.1
23.2
23.9
24.9
27.0
27.7
27.4

235
270
292
317
333
359
377
412
468
488
486

Bend
Radius
Load
(in)

Bend
Radius
Load
(cm)

Bend
Radius
No Load
(in)

Bend
Radius
No Load
(cm)

306
346
377
408
428
468
492
535
616
638
619

13
14
15
16
16
17
18
18
20
21
20

34
36
38
40
41
43
45
47
50
52
51

10
11
11
12
12
13
13
14
15
15
15

26
27
28
30
31
32
34
35
38
39
38

350
402
434
472
495
534
561
613
696
727
723

15
15
16
17
17
18
19
20
21
22
22

37
39
41
43
44
46
48
50
54
55
55

11
11
12
13
13
14
14
15
16
16
16

28
29
31
32
33
35
36
37
40
42
42

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.
Rated buffer storage length is 8 feet (2.4 meters)

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

604
20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Loose Tube Fiber Optic Cable


for Direct Burial (Polyethylene Duct)
PBT Tube or PE filler
Optical fibers
Central member
Central member jacket
Dielectric strength elements
Outer PE jacket
Water-blocking material

Ripcord

Application
Single jacket loose tube cable with a dielectric central strength member, reinforced with glass yarns and polyethylene jacket, designed for outdoor applications, for direct installations in duct. The cable is supplied in UV resistant high
density polyethylene (HDPE) duct.
Construction
Up to 12 optical fibers are enclosed in a polybutylene terephthalate (PBT)
tubes.
Up to 24 tubes are stranded around jacketed dielectric central member together with PE fillers to form the cable core.
The fibers and tubes are color coded for easy identification.
All the interstices in the cable core are filled with a water blocking materials to
prevent water penetration. Water swelling glass yarns are laid over the cable
core to serve as peripheral dielectric strength members.
A polyethylene jacket extruded over the glass yarns provides the final cable
shape and protection. A ripcord is provided under the jacket to facilitate its removal.
The cable is inserted into UV resistant high density polyethylene duct for wide
range of uses including extreme temperatures, abrasive and high tension applications in underground installations.
Cable Handling
Minimum bend radius with load
Minimum bend radius with no load
Minimum bend radius, storage coils
Maximum rated cable load (MRCL)
Maximum long term load

15 x OD
10 x OD
10 x OD
600 lbs (2700N)
180 lbs (800N)

Temperature Range
Installation
Operation
Storage

-300C to 600C (-220F to 1400F)


-600C to 700C (-760F to 1580F)
-400C to 750C (-400F to 1670F)

Polyethylene Duct Characteristics


General specification:
The duct is manufactured from virgin high density polyethylene
The ducts are supplied with smooth walls and come either in orange color or in
black with 3 orange stripes
The duct is capable of being coiled in continuous lengths, transported, stored
outdoors and subsequently uncoiled for installation without affecting its properties or performance
The duct performs in underground and above-ground installation an ambient
temperature range of minus 300F to 1300F
The duct specified for areal installations is ultraviolet light-resistant by UV light
stabilizer protecting the duct for a minimum of 12 months in direct sunlight
The duct is bent to a minimum (supported) radius of 10 outer diameters

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

606
20150407

FIBER OPTIC CABLES

Tests on finishing duct are performed in accordance with:


ASTM D3035 Polyethylene Plastic Pipe Based on Controlled Outside Diameter
ASTM D1248 Polyethylene Plastics Molding and Extrusion Materials (Type III,
Class A, B or C, Category 5, grade P34)
ASTM D1693 Environmental Stress Cracking of Ethylene Plastics (Cond. B,
F20/96 HRS)
ASTM D1238 Flow Rates of Thermoplastics by extrusion Plastometer
ASTM D638 Tensile properties of Plastics
ASTM D3350 Polyethylene Plastic Pipe and Fitting Materials (Cell #335440)
NEMA TC 7 Smooth-wall Coilable Polyethylene Electrical Plastic Duct

Loose Tube Fiber Optic Cable


for Direct Burial (Polyethylene Duct)
Cable Nominal Dimensions and Weight
FIBER COUNT
2-60

61-72

73-96

97-120

121-144

145-216

217-240

241-288

Cable Outer
Diameter
Cable
Weight

0.42
10.7
53
79

0.49
12.5
69
103

0.56
14.1
97
145

0.62
15.7
112
166

0.61
15.4
97
145

0.64
16.2
109
162

0.71
18
134
200

inch
mm
lb/kft
kg/km

0.4
10.1
47
70

Fiber Characteristics
PHYSICAL CHARACTERISTICS
Core Diameter
Clad Diameter
Core/Clad Concentricity Error (Offset)
Coating diameter
Tensile proof test
OPTICAL CHARACTERISTICS
Attenuation for Wavelength at 1310 nm
Attenuation for Wavelength at 1550 nm
Attenuation for Wavelength at 850 nm
Attenuation for Wavelength at 1300 nm
Zero Dispersion Wavelength (0)
MODE FIELD DIAMETER
for wavelength 1310 nm
for wavelength 1550 nm
Cut-off wavelength (cc)

Single Mode

m
m
m
m
kpsi

125.0 0.7
0.5,<0.2 typical
235-245
100

dB/km
dB/km
dB/km
dB/km
Nm

0.34 (max), 0.32 typical


0.21 (max), 0.19 typical
2.3 0.9
0.6 0.6
1302-1322

m
m
nm

9.2 0.4
10.4 0.5
1260

4
Brown

5
Slate

6
White

7
Red

Multi Mode
50/125
62.5/125
50.0 2.5
50.0 2.5
125.0 1.0
125.0 1.0
1.0
1.0
245 10
245 10
100
100

8
Black

1295-1340

9
Yellow

10
Violet

1320-1365

11
Rose

12
Aqua

FIBER OPTIC CABLES

Fibers and Tubes Color-Code per TIA/EIA 598A


FIBER NO.
1
2
3
COLOR
Blue
Orange
Green

Type

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
606
20150407

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

HDPE Conduit
Specifications
The material meets or exceeds the standards in ASTM D 3350-05 for Type III, Class PE 334480E (colors with UV stabilizer) or Class C (black), high density polyethylene.
Property Test
Density (g/cm3)
Melt Index (g/10 min)
Flexural Modulus (psi)
Tensile Strength @ Yield (psi)
ESCR, Condition B (10%, 50C)
Hydrostatic Design Basis (psi)

Method

Value

D792A or D1505
D1238
D790
D638
D1693
D2387

0.941 - 0.955
0.39 max.
80,000 min.
3,000 min.
F10 > 96 hours
NPR

* NPR - Not Pressure Rated

Ultraviolet Protection
Non-black conduit shall contain sufficient protection against UV radiation for a period not less than
one year. Black conduit contains sufficient protection against UV radiation in long term above
ground applications.
*Available with smooth or ribbed interior wall

Item #

Nominal
Size

Nominal
Outside
Diameter
(in)

Minimum
Wall
Thickness
(in)

Nominal
Inner
Diameter
(in)

Min. Bend
Radius
Unsupported
(in)

Max.
Pulling
Tension
(lb)

Weight
/MFT
(lb)

SDR11-13
SDR11-1/2
SDR11-3/4
SDR11-1
SDR11-1-1/4
SDR11-1-1/2
SDR11-2
SDR11-3
SDR11-4
SDR 13.5

13mm
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
3"
4"

0.625
0.840
1.050
1.315
1.660
1.900
2.375
3.500
4.500

0.055
0.076
0.095
0.120
0.151
0.173
0.216
0.318
0.409

0.500
0.668
0.840
1.055
1.338
1.533
1.917
2.826
3.633

8
10
12
14
18
20
26
48
60

210
390
605
950
1520
1760
3105
6740
11145

46
85
130
204
320
416
640
1386
2295

SDR13.5-1/2
SDR13.5-3/4
SDR13.5-1
SDR13.5-1-1/4
SDR13.5-1-1/2
SDR13.5-2
SDR13.5-3
SDR13.5-4

1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
3"
4"

0.840
1.050
1.315
1.660
1.900
2.375
3.500
4.500

0.062
0.078
0.097
0.123
0.141
0.176
0.259
0.333

0.696
0.874
1.101
1.394
1.598
2.002
2.951
3.794

10
12
14
18
20
26
48
60

320
505
790
1260
1455
2580
5590
9250

72
111
169
265
344
532
1154
1905

SDR 11

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

605
20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

PORTABLE POWER CABLES


Table of Contents
SOOW/SEOOW Control Cable ..............................................................................................701
Welding Cable ........................................................................................................................702
Type W RHH/RHW Single Conductor 600/2000V.................................................................703
Type W Magnet Crane Cable Two Conductor 600/2000V....................................................704
Type W Round Multi-Conductor 600/2000V.........................................................................705
Type G Round 600/2000V......................................................................................................706
MP-GC Mine Power Feeder 5kV-15kV ...................................................................................707
SHD-GC Portable Power Cable 2kV ......................................................................................708
Type DLO Diesel Locomotive Cable 2kV ..............................................................................709
Jumper Cable Transformer Lead Wire Non-Shielded 5kV/15kV .........................................710

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

700
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SOOW/SEOOW
Control Cables
Applications
Special uses requiring flexibility and mechanical toughness, high environmental resistance and
flame retardance. Push button remote controls. Motor control, stage equipment and lighting. Industrial control and robotic systems. Outdoor applications. Suitable and approved for submersion in
water.
Construction
Flexible and tough jacket. Offers -50C to 105C temperature extremes. Offers excellent abrasion,
ozone, sunlight, chemical and oil resistance as well as water and mold resistant non-wicking lightweight polypropylene fillers. Water resistant with high dielectric insulation. Lightweight, long lasting, easy to carry and easy to handle. All components are recyclable and non-hazardous for
environmental landfill disposal. Color coded conductors for easy identification.
Standards
Federal and Military use under Federal Spec. JC-580B. UL Listed SOOW/SEOOW 600V to NEC Article 400, MSHA approval for flame resistance for mining applications.
Color Code
2/C Black, White
3/C Black, White, Green
4/C Black, White, Red, Green
5/C Black, White, Red, Green, Orange
** Ampacity based on NEC Table 400-5(A) for sized 18/2 thru 10/4 and table 400-5 (B) for sizes 8/2 thru 2/5.

Note
Sizes up to 10/4 are UL/CSA/MSHA, sizes 8/2 to 2/5 are non-UL constructions made with wall thicknesses in accordance with industry standards and MSHA approved.
The ampacity is provided for engineering information only. The manufacturer cannot recommend or
express the use of these ampacities since the exact application may need approval from the authority having local jurisdiction. Above information is subject to engineering changes. Cold temperature
rating is -50C.

Size/
Conductors

Strands

Nominal
O.D.
(in)

Weight
/MFT
(lb)

Ampacity

22225
22325
22425
30505
22226
22326
22426
30506
22227
22327
22427
30507
22228
22328
22428
30508
22229
22329
22429
30509

18/2
18/3
18/4
18/5
16/2
16/3
16/4
16/5
14/2
14/3
14/4
14/5
12/2
12/3
12/4
12/5
10/2
10/3
10/4
10/5

16/30
16/30
16/30
16/30
26/30
26/30
26/30
26/30
41/30
41/30
41/30
41/30
65/30
65/30
65/30
65/30
104/30
104/30
104/30
104/30

0.345
0.365
0.39
0.465
0.37
0.39
0.415
0.495
0.5
0.525
0.565
0.645
0.57
0.595
0.645
0.71
0.62
0.655
0.705
0.765

61
71
84
113
74
87
103
140
129
151
180
232
173
203
247
301
218
265
324
387

10
10
7
5.6
13
13
10
8
18
18
15
12
25
25
20
16
30
30
25
20

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

701
20140110

PORTABLE
POWER CABLES

Item #

SOOW/SEOOW
Control Cables
Size/
Conductors

Strands

Nominal
O.D.
(in)

Weight
/MFT
(lb)

Ampacity

22220
22320
22420
22470
22221
22321
22421
22521
22222
22322
22422
22552
22223
22323
22423
22553

8/2
8/3
8/4
8/5
6/2
6/3
6/4
6/5
4/2
4/3
4/4
4/5
2/2
2/3
2/4
2/5

96/28
96/28
96/28
96/28
96/26
96/26
96/26
96/26
96/24
96/24
96/24
96/24
7x17/.0223
7x17/.0223
7x17/.0223
7x17/.0223

0.662
0.701
0.783
0.851
0.752
0.818
0.892
0.992
0.892
0.913
1.027
1.117
1.091
1.158
1.267
1.396

220
290
377
452
301
421
521
665
459
585
771
1029
665
940
1170
1419

40
40
35
28
55
45
45
36
70
70
60
48
95
95
80
64

PORTABLE
POWER CABLES

Item #

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
701
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Welding Cable
105C - 40C
Applications
Designed for connections from electrode holders and clamps to arc welders, bus welding box or
transformer.
Recommended for use in shipyards, mines, and other areas where cable is subject to extreme physical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable
handling.
This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and
could damage equipment.
Construction
Conductor is annealed rope stranded bare copper conductor per ICEA S-75-381.
Insulation is Ethylene Propylene Rubber (EPR) type EP, Class 45, 105 C. Table 50.55 of UL.1581.
Operating Voltage: 600V max.
Standards
Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.
Available on Request
Class M stranding
Colors
Hypalon or Neoprene Insulation
UL or CSA Listed
Custom Cut Lengths
Notes
Nominal resistance of conductor acc to ICEA S-75-381 Class K
Welding Machine Rating
Lengths up to 13.7m
45ft
Amps
AWG
mm2

Item #

W01-6
W02-4
W03-2
W04-1
W05-1/0
W06-2/0
W07-3/0
W08-4/0
W09-250
W10-350
W11-500

Lengths 14m to 30.5m


46ft to 100ft
AWG
mm2

Lengths 76.2m to 30.8m


101ft to 250ft
AWG
mm2

75

21

21

21

100

34

34

34

200

42

42

2/0

67

300

1/0

54

2/0

67

4/0

107

400

2/0

67

3/0

85

600

3/0

85

4/0

107

Size
AWG

Nominal
Stranding
Class K

Nominal
Resistance
of Conductor
/MFT@25C
(ohm)

Nominal
Thickness
of Insulation
(in)

Nominal
O.D.
(in)

Copper
Content
/MFT
(lb)

Weight
/MFT
(lb)

6
4
2
1
1/0
2/0
3/0
4/0
250MCM
350MCM
500MCM

285/30
412/30
647/30
817/30
1021/30
1289/30
1650/30
2065/30
2479/30
3416/30
4921/30

0.4190
0.2630
0.1670
0.1330
0.1050
0.0842
0.0668
0.0530
N/A
N/A
N/A

0.059
0.059
0.071
0.071
0.079
0.079
0.079
0.079
0.125
0.125
0.125

0.319
0.366
0.429
0.508
0.555
0.598
0.673
0.716
0.866
0.953
1.130

83
133
213
266
342
433
538
687
804
1120
1638

120
180
260
320
400
500
610
760
855
1255
1800

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

702
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Type W
Type RHH/RHW Single Conductor
90C UL 600/2000V
Applications
For use as portable power systems, entertainment industry activities such as theatre, television,
nightclubs, motion pictures, mobile communication vans, spotlights and sound permanent or temporary power. Permanent wiring of 600 volt power supplies, hoists, cranes and other applications
where flexible power leads must be installed in conduit or raceways.
Construction
Conductor is 8 500 MCM fully annealed stranded bare copper.
Insulation is premium grade 90C EPDM.
Jacket is black CPE.
Jacket marking is TYPE W PORTABLE POWER CABLE (UL) DRY 90C WET 75C 2000V SUNLIGHT
RESISTANT - P(#) MSHA-(SIZE)-TYPE RHH (UL) 600V.
Temperature range of -40C to +90C .
Voltage rating of 600 volt Type W.
Water and sunlight resistant.
Designed to withstand severe environmental conditions.
Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
Lengths cut to order.
Standards
Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL
Conforms to ICEA S-61-658
ICEA S-75-381 NEMA WC70 UL TYPE W and RHH or RHW-2 MSHA approved

Item #

Size
AWG

Conductor
Stranding

Nominal
Thickness of
Insulation
(in)

Nominal
Thickness of
Insulation
(mm)

Nominal
O.D.
(in)

Nominal
O.D.
(mm)

Current
Amps

Net
Weight
/MFT

S-01-W8
S-02-W6
S-03-W4
S-04-W2
S-05-W1
S-06-W10
S-07-W20
S-08-W30
S-09-W40
S-10-W250
S-11-W350
S-12-W500

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500

133
259
133
259
259
259
259
259
259
259
855
1235

0.06
0.06
0.06
0.06
0.08
0.08
0.08
0.08
0.08
0.095
0.095
0.095

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41

0.450
0.530
0.585
0.630
0.745
0.780
0.845
0.910
0.970
1.035
1.130
1.300

11.93
13.46
14.86
16.00
18.92
19.81
21.46
23.11
24.64
26.29
28.72
33.02

83
109
145
192
223
258
298
345
400
445
552
695

140
205
275
365
475
555
675
805
965
1165
1520
2100

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

703
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Type W
2-Conductor Magnet Crane Cable
600/2000V 90C
Applications
Magnet Crane Cable is a heavy duty, portable cable that is designed especially to use on magnet
cranes, and may be used on mobile mining equipment, lifting magnets, cutters, loaders, conveyers,
drills or pumps where grounded circuits are not required, in portable power situations and as temporary power supply.
Construction
Conductors are flexible stranded, annealed copper.
Insulation is Thermoset EPR.
Cabled with fillers for roundness with an open reinforced over assembly for mechanical protection.
Jacket is Thermoset CPE.
Standards
Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL
Conforms to ICEA S-61-658
ICEA S-75-381 NEMA WC-70 UL TYPE W and RHH or RHW-2 MSHA approved

Item #

MC1W-8
MC2W-6
MC3W-4
MC4W-2

No. of
Conductors

Size
AWG

Number of
Strands

Insulation
Thickness
(mil)

Overall
Diameter
(in)

Net Weight
/MFT.
(lb)

2
2
2
2

8
6
4
2

133
259
259
259

.060
.060
.060
.060

.81 Inches
.93 Inches
1.08 Inches
1.27 Inches

430 Lbs
590 Lbs
830 Lbs
970 Lbs

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

704
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Type W Round
Multi-Conductor
90C UL 600/2000V
Applications
For use in heavy duty services as power supply cable, AC systems (grounded and ungrounded),
mobile and portable electrical equipment, motor and battery leads. For 2 conductor cables use on
DC or AC single phase systems where no grounding is required, or on DC systems with one conductor for grounding. For 4 conductor cables, use on two or three phase AC systems with one conductor used for grounding. For 5 conductor cables, use in applications where separating the system
neutral from the frame ground is required.
Construction
Conductor is 8 - 500 MCM fully annealed stranded bare copper.
Insulation is premium grade color coded 90C EPDM.
Jacket is 90C Black CPE+ with temperature range of -40C to +90C .
Jacket is indent printed for easy identification (successive footage printing available).
Jacket marking is TYPE W PORTABLE POWER CABLE 2000V 90C DRY 75C WET SUN RES (UL) PK(#) MSHA
Designed to withstand severe environmental conditions.
Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound
for superior flexibility and toughness.
Suitable for continuous submersion in water.
Lengths cut to order.
Standards
ICEA S-75-381 NEMA WC-58 UL TYPE W and MSHA approved.
Notes
These ampacities are based on a conductor temperature of 90C and an ambient air temperature
of 40C per ICEA PUB-S-75-381 NEMA WC0-8. For ampacities per National Electrical Code requirements, refer to the latest NEC edition.
Shipping tolerance +/- 10%
Heavy duty neoprene jacket optional.
Successive footage printing available.

Item #

M01-2W8
M02-2W6
M03-2W4
M04-2W2
M05-2W1
M06-2W10
M07-2W20
M08-2W30
M09-2W40
M10-3W8
M11-3W6
M12-3W4
M13-3W2
M14-3W1
M15-3W10
M16-3W20
M17-3W30
M18-3W40

No. of
Conductors

Size
AWG

Conductor
Stranding

Nominal
Thickness of
Insulation
(in)

Nominal
Thickness of
Insulation
(mm)

Nominal
O.D.
(in)

Nominal
O.D.
(mm)

Current
Ampacity

Net
Weight
/MFT
(lb)

2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3

8
6
4
2
1
1/0
2/0
3/0
4/0
8
6
4
2
1
1/0
2/0
3/0
4/0

133
259
259
259
259
259
259
259
259
133
259
259
259
259
259
259
259
259

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.790
0.910
1.060
1.250
1.440
1.520
1.650
1.770
1.920
0.955
1.010
1.150
1.320
1.490
1.650
1.750
1.890
2.040

20.07
23.11
26.92
31.75
36.58
38.81
41.92
44.96
48.77
24.26
25.65
29.21
33.53
37.85
41.92
44.45
48.01
51.82

72
95
127
167
191
217
250
386
328
59
79
104
138
161
186
215
249
287

365
510
700
1015
1490
1710
1880
2420
2490
530
660
925
1325
1600
2280
2680
3220
3900

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

705
20140110

PORTABLE
POWER CABLES

www.buyawg.com

Type W Round
Multi-Conductor
90C UL 600/2000V
Item #

PORTABLE
POWER CABLES

M19-3W250
M20-3W350
M21-3W500
M22-4W8
M23-4W6
M24-4W4
M25-4W2
M26-4W1
M27-4W10
M28-4W20
M29-4W30
M30-4W40
M31-5W8
M32-5W6
M33-5W4
M34-5W2
M35-5W1
M36-5W10
M37-5W20
M38-5W30
M39-5W40

No. of
Conductors

Size
AWG

Conductor
Stranding

Nominal
Thickness of
Insulation
(in)

Nominal
Thickness of
Insulation
(mm)

Nominal
O.D.
(in)

Nominal
O.D.
(mm)

Current
Ampacity

Net
Weight
/MFT
(lb)

3
3
3
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5

250
350
500
8
6
4
2
1
1/0
2/0
3/0
4/0
8
6
4
2
1
1/0
2/0
3/0
4/0

327
855
1235
133
259
259
259
259
259
259
259
259
133
259
259
259
259
259
259
259
259

0.095
0.095
0.095
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

2.41
2.41
2.41
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

2.390
2.680
3.030
0.955
1.090
1.250
1.480
1.680
1.790
1.930
2.070
2.260
1.070
1.210
1.400
1.610
1.880
1.960
2.130
2.260
2.460

60.71
68.07
76.96
24.26
27.69
31.75
37.59
42.67
45.47
49.02
52.58
57.40
27.18
30.73
35.56
40.89
47.75
49.78
54.10
57.40
62.48

320
394
487
54
72
93
122
143
165
192
221
255
50
68
88
116
136
157
182
210
242

5070
6570
8700
620
825
1175
1650
2450
2570
3450
4050
4970
710
1010
1400
2340
3040
3460
4180
4900
5980

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
705
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Type G Round
90C 600/2000V
Applications
For use in heavy duty services as power supply cable, mobile and portable electrical. For 2 conductor cables use with AC single phase systems where grounding is required.
Construction
Conductor is 8 500 MCM fully annealed stranded bare copper.
Insulation is premium grade color coded 90C EPR.
Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound
for superior flexibillity and toughness.
Suitable for continuous submersion in water.
Jacket is 90C Black CPE with temperature range of -40C to +90C .
Jacket is Indent printed for easy identification (successive footage printing available).
Jacket marking is (SIZE) TYPE G-GC portable power cable 600/200V 90C sun oil resistant C(UL)
FT-5 (-40C) MSHA.
Lengths cut to order.
Standards
ICEA S-75-381 and MSHA approved.
Notes
These ampacities are based on a conductor temperature of 90C and an ambient air temperature
of 40 C per ICEA PUB-S-75-381 NEMA WC70. For ampacities per National Electrical Code requirements, refer to the latest NEC edition.
Shipping tolerance +/- 10%
Heavy duty neoprene jacket optional.
Succesive footage printing available.

Item #

2 Conductor
2-01-G8
2-02-G6
2-03-G4
2-04-G2
2-05-G1
2-07-G20
2-08-G30
2-09-G40
2-6-0G10

No. of
Conductors

Size
AWG

Conductor
Stranding

Grounding
Conductor
Size
AWG

2
2
2
2
2
2
2
2
2

8
6
4
2
1
2/0
3/0
4/0
1/0

133
259
259
259
259
259
259
259
259

2 # 10
2 # 10
2#8
2#6
2#5
2#3
2#2
2#1
2#4

Ground
Check
Size
AWG

Nominal
Nominal
Thickness of Thickness of
Insulation Insulation
(in)
(mm)
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

Nominal
O.D.
(in)

Nominal
O.D.
(mm)

Current
Ampacity

Net
Weight
/MFT
(lb)

0.81
0.93
1.08
1.27
1.44
1.65
1.77
1.92
1.52

20.57
23.62
27.43
32.26
36.58
41.91
44.96
48.77
38.61

72
95
127
167
191
250
286
328
217

495
650
940
1360
1730
2240
2860
3500
2000

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

706
20140110

PORTABLE
POWER CABLES

www.buyawg.com

Type G Round
90C 600/2000V
Item #

PORTABLE
POWER CABLES

3 Conductor
3-01-G8
3-02-G6
3-03-G4
3-04-G2
3-05-G1
3-06-G10
3-07-G20
3-08-G30
3-09-G40
3-10-G250
3-11-G350
3-12-G500
4 Conductor
4-01-G8
4-02-G6
4-03-G4
4-04-G2
4-05-G1
4-06-G10
4-07-G20
4-08-G30
4-09-G40

No. of
Conductors

Size
AWG

Conductor
Stranding

Grounding
Conductor
Size
AWG

Ground
Check
Size
AWG

3
3
3
3
3
3
3
3
3
3
3
3

8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500

133
259
259
259
259
259
259
259
259
627
855
1235

2 # 10
2 # 10
2#8
2#7
2#6
2#5
2#4
2#3
2#2
2#2
2 # 1/0
2 # 2/0

10
10
10
10
8
8
8
8
8
8
8
8

4
4
4
4
4
4
4
4
4

8
6
4
2
1
1/0
2/0
3/0
4/0

133
259
259
259
259
259
259
259
259

4 # 12
4 # 12
4 # 10
4#9
4#8
4#7
4#6
4#5
4#4

Nominal
Nominal
Thickness of Thickness of
Insulation Insulation
(in)
(mm)

Nominal
O.D.
(in)

Nominal
O.D.
(mm)

Current
Ampacity

Net
Weight
/MFT
(lb)

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41

0.965
1.050
1.165
1.340
1.510
1.650
1.750
1.890
2.040
2.390
2.680
3.030

24.51
26.67
29.59
34.04
38.35
41.91
44.45
48.01
51.82
60.71
68.07
76.96

59
79
104
138
161
186
215
249
287
320
394
487

665
830
1145
1485
2100
2550
3020
3660
4410
6060
7400
10100

0.06
0.06
0.06
0.06
0.08
0.08
0.08
0.08
0.08

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03

0.970
1.110
1.245
1.470
1.680
1.790
1.930
2.070
2.260

24.64
28.19
31.62
37.34
42.67
45.47
49.02
52.58
57.40

54
72
93
122
143
165
192
221
255

635
900
1280
2000
2660
3140
3780
4500
5520

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
706
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Type MP-GC
3-Conductor EPR or XLP 5kV-15kV
100% Insulation Level (Grounded) 90C
Applications
This cable is designed for high voltage connections between power distribution systems in mines,
mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is
required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing
service.
Construction
Conductor is stranded annealed copper enveloped in a strand shield.
Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the
interstices of the power conductors and fillers are added to make round.
A single faced rubber filled tape is applied overlapped.
5kV and 8kV jacket is Chlorinated Polyethylene (CPE).
15kV jacket is Polychloride (PVC); Jacket options include Chlorinated Polyethelene (CPE or Hypalon (SCSPE).
Standards
Conforms to ICEA S-75-381 NEMA WC70
Notes
Shipping tolerance +/- 10%

Item #

Power
Conductors
Number of
Strands

Power
Conductors
Insulation
Thickness
(in)

Ground
Wire
Size
AWG

Ground
Wire
Number of
Strands

Jacket
Thickness
(in)

Overall
Diameter
(in)

Net
Weight
/MFT
(lb)

4
2
1/0
2/0
4/0
250
350
500

7
7
19
19
19
37
37
37

.090
.090
.090
.090
.090
.090
.090
.090

7
5
3
2
1/0
1/0
2/0
4/0

7
7
7
7
19
19 s
19
19

1.32
1.45
1.63
1.75
2.00
2.13
2.35
2.64

.110
.110
.110
.140
.140
.140
.140
.170

1240
1670
2300
2730
3490
4620
5940
8160

4
2
1
1/0
2/0
4/0
250
350
500

7
7
19
19
19
19
37
37
37

0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115

8
6
5
4
3
1/0
2/0
3/0
4/0

7
7
7
7
7
19
19
19
19

0.11
0.11
0.11
0.11
0.14
0.14
0.14
0.14
0.14

1.43
1.55
1.65
1.75
1.88
2.12
2.25
2.46
2.75

1440
1760
2070
2440
2940
4130
4760
6090
8360

2
1/0
2/0
4/0
250
350
500

7
19
19
19
37
37
37

0.175
0.175
0.175
0.175
0.175
0.175
0.175

6
4
3
1
1/0
2/0
4/0

7
7
7
7
19
19
19

0.19
0.14
0.14
0.14
0.14
0.14
0.14

1.88
2.05
2.15
2.4
2.5
2.75
3.1

2190
2890
3350
4610
4990
6380
8770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

707
20140110

PORTABLE
POWER CABLES

5kV CPE
MP5-01-4
MP5-02-2
MP5-03-1/0
MP5-04-2/0
MP5-05-4/0
MP5-06-250
MP5-07-350
MP5-08-500
8kV CPE
MP8-01-4
MP8-02-2
MP8-03-1
MP8-04-1/0
MP8-05-2/0
MP8-06-4/0
MP8-07-250
MP8-08-350
MP8-09-500
15kV PVC
MP15-01-2
MP15-02-1/0
MP15-03-2/0
MP15-04-4/0
MP15-05-250
MP15-06-350
MP15-01-500

Power
Conductors
Size
AWG

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

SHD-GC
3-Conductor EPR/CPE 2kV
100% Insulation Level 90C
Applications
This cable is designed for heavy duty high voltage portable power trailing cable between the load
center and equipment such as power shovels, draglines, and other excavators and is suitable for
use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and
maximum safety is required.
Construction
Conductor is extra flexible, stranded, tinned annealed copper.
Insulation is Ethylene Propylene Rubber (EPR).
Covered grounding and 8-gauge ground check conductors.
Jacket is Black Chlorinated Polyethylene (CPE).
Standards
Conforms to ICEA S-75-381 NEMA WC70
Notes
Neoprene jacket optional.
Shipping tolerance +/- 10%

Item #

Power
Conductors
Size
AWG

Power
Conductors
Number of
Strands

Power
Conductors
Insulation
Thickness
(in)

Ground
Wire
Size
AWG

Ground
Wire
Number of
Strands

Jacket
Thickness
(in)

Overall
Diameter
(in)

Net
Weight
/MFT
(lb)

6
4
2
1/0
2/0
4/0
250
350
500

133
133
259
266
342
532
427
427
427

.110
.110
.110
.110
.110
.110
.120
.120
.120

10
8
6
4
2
1
1/0
2/0
4/0

49
133
133
133
133
259
259
259
259

.185
.185
.205
.220
.220
.235
.250
.265
.280

1.56
1.68
1.87
2.08
2.20
2.50
2.69
2.95
3.31

1460
1690
2290
3110
3570
4990
5820
7540
9840

2kV
DL01-5-6
DL05-5-4
DL03-5-5
DL04-5-1/0
DL05-5-5/0
DL06-5-4/0
DL07-5-550
DL08-5-350
DL09-5-500

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

708
20140110

PORTABLE
POWER CABLES

www.buyawg.com

Type SHD-GC
3-Conductor EPR/CPE 2kV
100% Insulation Level 90C
Item #

Power
Conductors
Size
AWG

Power
Conductors
Number of
Strands

Power
Conductors
Insulation
Thickness
(in)

Ground
Wire
Size
AWG

Ground
Wire
Number of
Strands

Jacket
Thickness
(in)

Overall
Diameter
(in)

Net
Weight
/MFT
(lb)

6
4
2
1/0
2/0
4/0
250
350
500

133
133
259
266
342
532
427
427
427

.070
.070
.070
.080
.080
.080
.095
.095
.095

10
8
6
4
2
1
1/0
2/0
4/0

19
133
133
133
133
133
133
133
259

.155
.155
.170
.190
.250
.220
.220
.235
.265

4
2
1/0
2/0
4/0
250
350
500

133
133
259
259
259
427
427
427

150
150
150
150
150
150
150
150

8
6
4
3
1
1/0
2/0
4/0

49
133
133
133
133
259
259
250

.205
.220
.220
.235
.250
.250
.280
.295

1.94
2.12
2.32
2.46
2.75
2.89
3.20
3.56

2240
2730
3380
4030
5440
6280
8300
12000

2
1/0
2/0
4/0

133
259
259
259

210
210
210
210

6
4
3
1

133
133
133
259

.235
.250
.250
.265

2.41
2.64
2.73
3.05

2950
3650
4250
5930

1/0
2/0
4/0

259
259
259

295
295
295

4
3
1

133
133
259

.265
.280
.295

3.05
3.20
3.50

5250
6000
7710

5kV

PORTABLE
POWER CABLES

DL01-2-6
DL02-2-4
DL03-2-2
DL04-2-1/0
DL05-2-2/0
DL06-2-4/0
DL07-2-250
DL08-2-350
DL09-2-500
8kV
DL01-8-4
DL02-8-2
DL03-8-1/0
DL04-8-2/0
DL05-8-4/0
DL06-8-250
DL07-8-350
DL01-8-500
15kV
DL01-15-2
DL02-15-1/0
DL03-15-2/0
DL04-15-4/0
25kV
DL02-25-2/0
DL03-25-4/0
DL04-25-250

960
1410
1940
2950
3470
4800
5950
7400
10100

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
708
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Type DLO
Diesel Locomotive Cable
600/2000V 90C
Applications
This cable is for wiring down tower applications and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor
and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs.
Construction
Conductor is extra flexible tinned, stranded copper with a separator layer.
EPR insulation.
Jacket is CPE (Hypalon jacket available upon request).
Standards
Meets flame test requirements of MSHA and passes ICEA cold bend test at -40C.
Meets AAR specifications.
UL listed as RHH-RHW-2.
Rated for CT use, 1/0 and larger.
Notes
Ampacity based on single conductor in free air, 90C conductor temperature, 40C ambient per
ICEAS-75-381.
Sequential footage marks.
Shipping tolerance +/- 10%

Item #

Area
Circular
(mil)

Size
AWG

Number of
Strands in
Conductor

Insulation
Thickness
(in)

Jacket
Thickness
(mil)

Overall
Diameter
(in)

Net Weight
/MFT
(lb)

Ampacity
1/C Free Air
90C

DL-600/2-1
DL-600/2-2
DL-600/2-3
DL-600/2-4
DL-600/2-5
DL-600/2-6
DL-600/2-7
DL-600/2-8
DL-600/2-9
DL-600/2-10
DL-600/2-11
DL-600/2-12
DL-600/2-13
DL-600/2-14
DL-600/2-15
DL-600/2-16
DL-600/2-17
DL-600/2-18
DL-600/2-19
DL-600/2-20
DL-600/2-21
DL-600/2-22

3831
6088
10910
14950
24640
36760
42420
60600
90900
111100
131300
181800
222200
262600
313100
373700
444400
535300
646400
777700
929200
1111000

14
12
10
8
6
5
4
2
1
1/0
2/0
3/0
4/0
262.6
313.1
373.7
444.4
535.3
646.4
777.7
929.2
1111.0

19
19
27
37
61
91
105
150
225
275
325
450
550
650
775
925
1100
1325
1591
1924
2299
2745

.045
.045
.045
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.090
.090
.090
.090
.110
.110
.110
.110
.110

30
30
30
30
30
30
30
30
45
45
45
45
45
65
65
65
65
65
65
65
65
65

.24
.25
.29
.33
.40
.43
.45
.50
.64
.69
.73
.80
.86
.97
1.01
1.11
1.18
1.29
1.38
1.47
1.58
1.74

34
45
68
82
125
175
195
265
425
500
570
780
890
1100
1280
1500
1760
2110
2410
2930
3450
4130

32
36
55
83
109
127
145
192
223
258
298
345
400
458
514
574
642
725
815
910
1025
1143

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

709
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Jumper Cable
Transformer Lead Wire
Non-Shielded 5kV/15kV 90C
Applications
This cable is for use as flexible power leads permitting temporary connections or bypassing energized power lines at voltages up through 15kV, phase to phase.
Installation
These cables must be positioned away from contact with grounds, transformer cases, cross-arms,
etc. to avoid possible high stress and capacitance leakage due to the fact that jumper cables cannot
be protected against prolonged contact with other conductors or grounds by shielding.
Construction
Conductor is flexible stranded copper conductor with a semi-conducting strand shield covering.
Insulation is Ethylene Propylene Rubber (EPR).
Jacket is heavy duty, red NBR/PVC jacket.
Rating is 5KV/15KV, 90C.
Non-Shielded
Standards
ICEA S-75-381 NEMA WC70

Item #

Size
AWG

Number of
Strands

Overall Diameter
(in)

J1-5/15-2
J2-5/15-10
J3-5/15-20
J4-5/15-40
J5-5/15-350
J6-5/15-500

2
1/0
2/0
4/0
350
500

259
259
259
516
855
1235

0.900
0.985
1.040
1.165
1.416
1.580

Net Weight
/MFT
(lb)
550
730
850
1174
2220
2377

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice.
Copyright 2016, American Wire Group, Inc.

710
20140110

PORTABLE
POWER CABLES

www.buyawg.com

PORTABLE
POWER CABLES

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

APPENDIX
Table of Contents
Terms & Conditions/Warranty ..................................................................................................A
Wire & Cable: Handling and Installation Engineering Guide ................................................H
Jacket Material Selection Chart................................................................................................K
EPR Performance Specifications ..............................................................................................L
Thermal Resistivity of Materials .............................................................................................M
Guide for the Installation of ACSR Twisted Pair (TP) Conductor ............................................J
Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B
Recommended Reel Handling Practices & Recycling/Reel Return ........................................C
Steel Reel Specifications ..........................................................................................................D
Cabling.........................................................................................................................................I
Metric Size to AWG Size............................................................................................................E
Copper Conductor Stranding Chart: Class A thru M ..............................................................G
Wire & Cable: Glossary of Terms ..............................................................................................F

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

000
20151015

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

NOTES

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Terms & Conditions


Warranty
Price
Prices are based on COMEX copper or LME aluminum listed on the
quotation. Prices are subject to copper/aluminum adjustment at the
time of shipment in the event that COMEX or LME copper exceeds
the quoted base in excess of 10%.
Cancellation
Cancellation after acceptance of an order cannot be made without
Sellers written consent and on such conditions as will indemnify
Seller against loss for commitments made and work already complete and/or in process.
Special Orders
When Special Make Orders are accepted the entire order must be
taken. Special Make Orders cannot be cancelled or modified once
accepted and cannot be returned.
Tolerances
Non-Stock & Special Make merchandise is subject to the following
tolerances: Total product -0 and Reel lengths +/-10%, or as specified. Exact reel lengths will incur additional charges.
Delivery
Any shipment schedule is approximate. Seller shall not be liable for
any delay in delivery or failure to deliver caused in whole or in part
by any reason beyond Sellers control.
Claims
Buyer agrees to inspect merchandise for defects and for conformity, and agrees to check material against shipping papers upon unloading at destination. All claims for shortages or defective
merchandise must be made by Buyer in writing within seven (7)
days of receipt of shipment.
Returns
Return merchandise must be full reels or cartons, undamaged and
in the original unopened package. Credit will be given for returned
merchandise only for full reels of undamaged wire if still in the
original package. No merchandise may be returned without the
written authority of Seller and receipt of Sellers RMA number. No
merchandise may be returned after the expiration of sixty (60) days
following the date of shipment. Returns may be subject to a Restocking Fee. Non-Stock & Special Make merchandise will not be
considered for return and is not subject to the previous stated return conditions.
Refunds
No cash refunds. Trade Credit Only. All returns and other proper
claims for credit may be applied toward future purchases only or
as agreed.
Taxes
Liability for all taxes imposed by any government authority with respect to the goods herein ordered shall be assumed and paid by
Buyer.
Modifications
Any modification of these Standard Terms and Conditions shall not
be binding on Seller unless signed on behalf of Seller by a representative authorized to do so, regardless of whether Seller has
commenced shipping of any merchandise ordered hereunder or
whether Seller has accepted payments therefore.

Warranty
All merchandise ordered will be supplied in accordance with the
description on the face of the order acknowledgment and in accordance with applicable specifications and design standards, and will
be substantially free from defects in material and workmanship.
The Sellers liability in respect to any defect in or failure of the merchandise supplied, as well as any loss, injury or damage attributable thereto, is limited to the replacement or repair of defects which,
under proper use and handling, have been proven to the Sellers
satisfaction to arise solely from faulty design, materials or workmanship, within a period of one (1) year from the date of shipment
from the Sellers factory. Further, the Seller must be notified in writing of the said defect or failure within a period of one (1) year from
the date of shipment. The replacement of such merchandise does
not include expenses incurred in the installation or use of the material. No merchandise shall be returned to the Sellers factory or
warehouse for credit or replacement before the Seller has officially
advised of this transaction.
Warranty Limitations
This warranty does not cover the repair or replacement of any
cable which fails as a result of damage in transit, misuse, neglect,
accident, Acts of God, abuse, improper handling, improper storage,
excessive stress, faulty or improper or unauthorized installation or
repair, negligent maintenance or failure to comply with the written
instructions for installation, use or maintenance provided by the
Seller.
Exclusion of Other Warranties
This warranty is in lieu of all other warranties, express or implied,
and all other warranties, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose,
are expressly disclaimed.
Limitation of Liability and Limitation of Actions
In no event shall Seller be liable for any indirect, incidental, special,
punitive or consequential loss, damage or expense (which shall be
deemed to include without limitation: any loss of profit or revenue,
loss of goodwill, loss claimed by end-users customers, or loss of
business opportunity) of any nature or kind, however arising,
whether in contract, in tort or otherwise, even if Seller is deemed to
be aware of the possibility of such damages. Sellers maximum liability for any claim, loss or damage shall not exceed the purchase
price for the cable subject to a claim under any circumstance, even
if end-user has claims or is subject to claims in excess of this limitation. Any legal proceeding related to this warranty must be presented within (1) year after the cause of action arises.
Sole and Exclusive Remedy
This document sets forth the Sellers sole and exclusive warranty
obligation to the Buyer and the Buyers sole and exclusive remedy
in the event of defective cable.
Choice of Law
The laws of the State of Florida, without giving effect to its conflicts
of law principles, govern all matters arising out of or relating to
these Standard Terms and Conditions and all the transactions it
contemplates, including, without limitation, its validity, interpretation, construction, performance and enforcement.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

A
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

NOTES

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
Receiving and Handling Cable .............................................H1
Receipt of Cable Reels ..........................................................H1
1. Visually check for shipment damage............................H1
2. Inspect reel tags .............................................................H1
3. Check dimensional tolerances ......................................H1
Handling of Cable Reels........................................................H1
Storage of Cable Reels ......................................................H2
Installation Suggestions .......................................................H2
Safety Measures Prior to Pulling Cable ...........................H2
Temperature Considerations.........................................H2
Duct Sizing......................................................................H2
Jam Ratio........................................................................H2
Cable Clearance .............................................................H3
Minimum Bending Radius (Static Conditions) ............H3
Minimum Bending Radius (Dynamic Conditions).......H3
Cable Training (Offset Bending) ....................................H3
Power and Control Cables without Metallic Shielding or Armor.H4
Power and Control Cables with Metallic Shielding or Armor ......H4
Clearing Ducts ................................................................H4
Trench for Direct Burial..................................................H4
Rack/Trays .......................................................................H4
Precautions During Cable Pulling .................................H4
Cable Guides ..................................................................H4
Cable Lubricant ..............................................................H5
Pulling Eyes & Grips ......................................................H5
Maximum Pulling Tensions ...........................................H5
A. Pulling Eye..............................................................H5
B. Cable grips..............................................................H6
Sidewall Bearing Pressure (Static Conditions) ............H6
Sidewall Bearing Pressure (Dynamic Conditions).......H7
Special Conditions for Metallic Armored Cables................H7
Sheath Currents and Voltages in Single Conductor Cables......H7
Eliminating Sheath Currents.............................................H7
Standing Voltage................................................................H8
Installation of Single Conductor Cables in Parallel ............H8
Reel Capacities...................................................................H8
NEMA Method................................................................H8
Handling of Cables Reels......................................................H9
Shipment for Unloading with a Forklift at Dock................H10
Shipment for Unloading down an Inclined Ramp ............H10
Shipment for Unloading with a Forklift at Jobsite............H10
Unloading from Open Flat Bed Trailers..............................H11
Cable Reel Handling............................................................H12

Receiving and Handling Cable


In order to benefit from investing in underground cable (power
cable), the purchaser should put into practice a complete visual inspection program that will help identify any cable that is damaged
during shipment. If any cable is undesirable, it is then returned to
the manufacturer instead of being installed. By recognizing and refusing damaged cable, one can considerably improve the dependability of the underground system.

Receipt of Cable Reels


Once the purchaser has received the cable shipments, they should
carry out an approval inspection. A cable approval inspection involves some straightforward and low-cost steps that can yield significant dividends.
The following steps should be taken to insure proper acceptance of
cable:
1. Visually check for shipment damage
Visually check cable reels for any damage that may have taken
place during delivery. The purchaser should be mainly worried for
cable damage if:
a. A reel is laying flat on its side, especially if it is a large conductor size, such as 500 kcm, 750 kcm, or 1,000 kcm
b. Numerous reels are piled on top of each other
c. Other cargo is piled on the reel
d. Nails have been driven into the overhang to prevent overcrowding
e. A reel overhang is broken
f. A cable covering is detached, discolored, or broken
g. A cable end seal is detached or broken (a broken or absent end
seal means that moisture may have come into the cable)
h. A reel has fallen (concealed damage likely)
2. Inspect reel tags
Visually check each reel to assure that it has the correct tags and labels as noted in the specifications. The reel should contain the subsequent minimum information:
a. Purchasers name and address
b. Purchase order number
c. Conductor size and type
d. Insulation thickness and type
e. Jacket type
f. Quantity of cable on reel
g. Beginning and ending sequential footage numbers present on
the jacket
Confirm that the cable description, reel size, and cable footage are
equivalent to that specified. Any missing information should be acquired from the manufacturer.
3. Check dimensional tolerances
Make a straightforward measurement of the cable dimensions on
one reel of each size of cable in a shipment to prove that the cables
dimensions meet the requirement.

Handling of Cable Reels


To guarantee that material handling equipment does not touch or
interfere with cable surfaces or with protective covering on the reel,
the utmost care should be taken when moving the cable reels. It is
very important that cable reels not be dropped from any height, or
be allowed to roll unrestrained. Cable reels should be moved or
lifted using the technique depicted at the end of this document.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H1
20140401

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
1. For cranes, booms, or other overhead lifting equipment, a
sturdy steel arbor or heavy rod or pipe should be placed in
through the reel hubs so that the cable reel can be lifted by
slings that make the most of spreader bars. This technique will
assure that sling pressure against a reel flange, slanting of the
reel, sliding of the sling, and other unstable situation will be reduced.
2. When lifting reels by fork truck type equipment, reels should
only be lifted from the sides, and only if the blades of the fork
truck are long enough to support both flanges. This way will
make sure that the lift pressure is uniformly dispersed on both
flanges and not on the cable itself.
3. Rolling reels containing cables should be kept to a minimum; if
rolling is necessary, reels should always be rolled in the direction indicated by the arrows on the sides of the reel flanges or
in the opposite direction to which the cable is wrapped onto the
reel. Rolling the reels this way will avoid the release of the cable
wraps, which may lead to problems during installation.
4. It is important that any debris be cleared from the path over
which the cable reels are to be rolled since that might damage
the cable if the reels were to roll over it. Cable reels should be
rolled in the direction of the Roll This Way arrow and lowered
in a controlled manner. The ramps should be spaced far enough
apart so that they are touching the reel flanges at all times.
Storage of Cable Reels
Cable reels should not be stored on their sides if at all possible.
To prevent deterioration of the reels and moisture seeping into the
cables, it is preferable to store cable reels indoors on a hard, dry
surface.
If cable reels are stored outdoors they must be supported off the
ground and protected with a suitable weatherproof material. The
reel supports should be at least twice the width of the reel flange,
long enough to provide a sufficient load bearing surface (to prevent sinking), and high enough to prevent the reel from sitting in
free standing water in case of rain. Reel supports should be placed
under each reel flange, and to prevent rolling each reel should be
placed between the reel flange and the support at opposite sides of
the flange.
All cable reels should be stored in such a way so as to allow easy
access for lifting and moving, away from construction activities,
falling or lying objects, sources of high heat, open flames, chemicals or petroleum products, etc. that may cause damage to the
cable. It is also recommended to use fences or any other suitable
barriers to protect cables and reels against damage by vehicles or
other moving equipment in the storage area.
If the cable is stored on reels for future use after the factory applied
end caps are removed, the exposed cable ends MUST be re-sealed
using properly applied weatherproof end caps or by taping the
ends with a tape designed to prevent moisture. PVC tapes or Duct
Tape are not appropriate for preventing moisture. One must secure
the loose ends of the cable reels to the reel flange and cannot lie
on the ground.
Reels and end caps should be inspected from time to time if they
will be stored outside for a long period of time. A once a month inspection is suitable at first but one should consider increasing this
if storage time is extended since wooden reels tend to deteriorate
over time and sealed end caps will lose their usefulness. Rates of
deterioration will vary depending on the environment in which the
reels are stored.

NOTE: If a specific method of shipping is used, such as shipping to


a job site, etc., the manufacturer must be notified of these special
requirements.

Installation Suggestions
Below you will find a general guide for the installation of shielded
and unshielded cables, jacketed cables rated 600 to 35,000 volts in
conduit, underground ducts, racks, trays or direct buried.
Safety Measures Prior to Pulling Cable
Temperature Considerations
It is important to consider that low temperatures create handling
and pulling difficulties of varying degrees, depending on cable construction and installation location. Most cables can be safely handled if not subjected to temperatures lower than -10C (14F) in the
twenty-four (24) hour period prior to pulling and bending the cable.
If temperatures do fall below these values during the following 24
hour period, measures should be taken to transport the cable to a
warm storage area. The cable should be exposed to a temperature
of 15C (60F) for 24 hours to ensure warm-up. Pulling eyes, if necessary, should be set up. If the cable is installed during cold
weather conditions, cable should be pulled more slowly and
trained in place the same day it is removed from the warm storage
area. The cable should also not be dropped or bent if cold outside.
Duct Sizing
Select duct size in such a way that the difference between the hoop
diameter of the cable(s) and the inside diameter of the duct will not
be less than . Also check that the cross-sectional area of the cable
is not more than the percentage of the interior cross-sectional area
of the conduit, as recommended by the National Electric Code
(NEC). In addition, consider using larger ducts or additional pull
boxes if long pulls are required.
Jam Ratio
Jamming might occur in bends if three cables are pulled in parallel
in duct. This happens when the cables adjust from a triangular pattern to a cradled pattern as they are pulled in through the bend.
This pattern change will force the two outer cables to move farther
apart. The cables will also jam if the conduit diameter is too small
to contain the wider pattern.
To prevent this, the jam ratio should be checked. The jam ratio corresponds to the inside diameter of the duct to the cable diameter,
such that:

J=Dd
Where:
J = Jam ratio
D = Inside diameter of duct (in)
d = Outside diameter of cable (in)
The proper cable configuration can be determined if the above jam
ratio is calculated. The likely configurations are as follows:
Jam Ratio
Cable Configuration
J < 2.4
Triangular
2.4 < J < 2.6
More likely triangular
2.6 < J < 2.8
Either triangular or cradled
2.8 < J < 3.0
More likely cradles
J > 3.0
Cradled

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H2
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable:


Handling and Installation Engineering Guide
Cable jamming tends to occur between J = 2.8 and J = 3.1. This is
true if the sidewall bearing pressure (SWBP) in a bend surpasses
the 1,000 lbs/foot.
Cable Clearance
In order to make sure that the cables can be pulled through the
conduit, specifically in applications where the National Electric
Code (NEC) limits on conduit fill do not apply, one needs to calculate the clearance between the cable(s) and conduit. The recommended calculated clearance should not be less than 0.5 inches.
However, a lesser clearance, such as 0.25 inches, may be suitable
for primarily straight pulls.
In addition, the clearance should contain the pulling eye or cable
grip, which is used for the cable pull. The formulas below can be
used to calculate the cable clearance for a single cable pull and for
a three-cable pull. (Please Note: To allow for differences in cable
and duct dimensions and ovality of the duct at bends, the nominal
cable diameter d has been increased by 5%).
a. Single Cable Pull

C = D 1.05 x d
b. Three Cable Pull (triangular pattern)

(D 1.05 x d)
D
C = __ 1.366 (1.05 x d) + ____________ x
2
2

calculating conduit or tubing fill. The actual dimensions of the


equipment grounding or bonding conductor (insulated or bare)
shall be used in the calculation.
The below formula can be used when a calculation must be made
to comply with the NEC fill ratio requirements:

FR = [NPC x PCD 2)2 + NGC x (GCD 2}2] (CD 2)2


Where:
FR = Fill Ratio (%)
NPC = Number of Phase Conductors with the same diameter
PCD = Diameter of Phase Conductor (in)
NGC = Number of Ground Conductors with the same diameter
GCD = Diameter of Ground Conductor (in)
CD = Diameter of Conduit or Duct (in)
Minimum Bending Radius (Static Conditions)
The following formula can be used to determine the minimum values for the radii to which such cables may be bent for permanent
training:

MBR = OD x M
1

1.05 x d
____________
(D 1.05 x d)

Where:
C = Cable clearance (in)
D = Inside diameter of duct (in)
d = Outside diameter of cable (in)
Please reference the following table in dealing with applications
where the National Electric Code (NEC) is compulsory. The table
shows the most ordinary scenarios concerning the fill ratio of
many cable configurations in various duct sizes.
Conductor Fill Per NEC Code
Duct
1 Conductor
2 Conductors
3 Conductors
4 conductors
Sizes (53% Fill Ratio) (31% Fill Ratio) (40% Fill Ratio) (40% Fill Ratio)
(in)
Area Dmax
Area Dmax
Area Dmax
Area Dmax
(in2)
(in)
(in2)
(in)
(in2)
(in)
(in2)
(in)

0.16 0.453
0.09 0.245
0.12 0.227
0.12 0.197

0.28
0.6
0.16 0.324
0.21 0.301
0.21 0.261
1
0.46 0.764
0.27 0.413
0.34 0.383
0.34 0.332
1
0.80 1.005
0.47 0.543
0.60 0.504
0.60 0.436
1
1.08 1.172
0.63 0.634
0.82 0.588
0.82 0.509
2
1.78 1.505
1.04 0.814
1.34 0.755
1.34 0.654
2
2.54 1.797
1.48 0.972
1.92 0.902
1.92 0.781
3
3.91 2.234
2.26 1.208
2.95 1.12
2.95 0.97
3
5.25 2.583
3.07 1.397
3.96 1.296
3.96 1.122
4
6.74 2.931
3.94 1.585
5.09 1.47
5.09 1.273
5
10.60 3.674
6.20 1.987
8.00 1.843
8.00 1.596
6
15.31 4.415
8.96 2.388
11.56 2.215
11.56 1.918
Please Note: dmax(in) is the maximum single conductor diameter
that will comply with the above requirements. Area (in2) is the
area of the conductor(s). Ground wires have not been considered
in the above table. The NEC requires that Equipment grounding
or bonding conductors, where installed, shall be included when

Where:
MBR = Minimum radius of bend (in)
OD = Outside diameter of cable (in)
M = Diameter multiplier (Please see tables on the next page(s))
Note: The above calculation applies to STATIC conditions ONLY.
Please reference the DYNAMIC conditions section below and the
Sidewall Bearing Pressure section for the minimum bending radius
of cable in motion.
Minimum Bending Radius (Dynamic Conditions)
The following formula can be used to determine the minimum values for the radii to which such cables may be bent while being
pulled into an installation and while under tension. This value will
largely depend on the tension the cable experiences as it exits the
bend. The greater the exiting tension, the greater the minimumbending radius will be for the cable.

MBR = (Te SWBP) X 12 (in)


Where:
MBR = Minimum radius of bend (in)
Te = Tension as cable exits the bend (pounds x force)
SWBP = Maximum allowable Sidewall Bearing Pressure (pounds
x force per foot of bend radius)
Cable Training (Offset bending)
You may use the following formula to determine the minimum distance necessary for permanent cable training (offset bending) in a
manhole:

L = S (4 R S)
Where:
L = Minimum distance required (in)
S = Offset (in)
R = Bending radius to cable centerline (in)

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H3
20140401

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide

*For conductor sizes 1500kcm and larger, the minimum bending radius for
LC Shielded cable is 18X the cable diameter.

Note 1: Multiply the diameter of the cable by the factor in the table
above to attain the minimum-bending radius.
Note 2: These limits may not be appropriate for use with conduit
bends, sheaves or other curved surfaces around which the cable
may be pulled under tension while being installed due to sidewall
bearing pressure limits. The minimum radius specified refers to the
inner radius of the cable bend and not to the axis of the cable.

L
R

Allow a suitable length of straight cable at both ends of the offset


bend.

Clearing Ducts
Using a plug that is roughly the same diameter as the inside of the
duct does not permit obstructions in the duct since it pulls the plug
through the structure. After doing this, use a wire brush to clean
and remove foreign matter from the duct. In order to prevent
scratch damage to the cable jacket during pulling, it is important to
smooth the interior.

Power and Control Cables without Metallic Shielding or Armor


Insulation
Thickness
(mil)
155 and less
156 to 310
310 and over

Overall Diameter of Cable


(in)
1.000 and Less
1.001 to 2.000
2.001 and Over
Minimum Bending Radius as a Multiple of Cable Diameter
4
5
6
5
6
7

7
8

Note 1: The highest applicable multiplier should be used in all


cases. The calculated minimum bend radius (applicable multiplier x
outside diameter of cable) refers to the inner surface of the bent
cable, and not the axis (centerline) of the cable conduit.
Note 2: Use the thickest of the insulations of the cables within the
assembly and the diameter of the largest single cable within the
cable assembly to determine the multiplier. Afterwards, apply that
multiplier to the diameter of the overall assembly.
Note 3: The minimum values for the radii to which cables may be
bent during installation may not apply to conduit bends, sheaves
or other curved surfaces around which the cable may be pulled
under tension while being installed. Larger radii bends may be required for such conditions. (Please reference Precautions during
Cable Pulling in the Sidewall Bearing Pressure section).

Power and Control Cables with Metallic Shielding or Armor


Cable Type

Minimum Bending Radius Minimum Bending Radius


For Single Conductors
For Multiple Conductors
Interlocked and Polymeric
Armor (without shielded
conductor)
7
7
Interlocked Armor and
Polymeric Armor (with
shielded conductor)
12
7
Wired Armored Cable
12
12
Metallic Tape Shielded Cable 12
7
Metallic Fine Wire Shield
12
7
Concentric Neutral Wire
Shielded Cable
8
5
Lead Sheath Cable
12
7
LC Shielded Cable
12*
7
Use the larger of the two minimum bending radii when considering the
minimum-bending radius for multiple conductors.

Trench for Direct Burial


To prevent damage to the cable jacket during or after cable installation, the trench should be clean of sharp stone, glass, metal or
wood debris. The trench bottom should be evenly covered with a
layer of soil or sand that has been screened through a medium-tofine mesh screen to remove all larger stones or other material. This
will assure a smooth, soft-bedding surface for the cable(s). It is a
good idea to lay a protective covering on the fill about 6-8 inches
above the cable to protect it if working in an urban area or near
where a lot of digging occurs. If working under highways or railroad rights-of-way, it is also a good idea to install the cable in a
pipe or conduit to give added mechanical protection.
Rack/Trays
One should check the entire path that the cable will follow during
pulling to make sure that the cable will have a smooth ride, free of
all barriers or sharp edges. In checking this, one should consider
the position the cable will take on when under tension.
Precautions During Cable Pulling
Cable Guides
All guides should be in the form of large diameter, smooth-surfaced, free-turning sheaves or rollers to prevent damage to the
cable jacket when guiding the cable from the reel to the duct
mouth or trench. Guide tubes or chutes must be smooth, burr-free
working surfaces with the largest possible bend radii and be securely anchored if used. Mounting the cable reel in sturdy jacks,
leveling the reel shaft and lubricating the reel arbor holes with
grease will lead to low cable tension. If breaking the reel needs to
happen, it should only be done to prevent reel over-run when the
pull is slowed or stopped, or on steep downhill runs where cable
weight is enough to overcome cable-duct friction.
This information also applies for rack or tray installations. The following points should be noted when making such pulls:
1. Cable support rollers should be spaced close enough so that the
cables normal sag, even when under tension, will not result in
tray dragging.
2. The cable rollers should be contoured so that the cable will not
ride off the end of the roller or be pinched into a sheave contour diameter that is smaller than that of the cable.
3. When rollers or sheaves are used to guide the cable through the
bends, it is important that enough of them be used to guide the

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H4
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable:


Handling and Installation Engineering Guide
cable in a smooth curve of the desired radius from tangent
point to tangent point. If this is not done, the cable may be
kinked around the radius of each roller.
The cable may be paid off the reel and laid into the trench as the
reel is moved along the length of the trench in cases of direct-burial installations. When this happens, the cable is laid on a bed of
soil or sand.
If the cable needs to be pulled through the trench, the best way to
do so is to support the cable on temporary rollers so that the cable
does not drag over the soil or sand bed. If one does not have
rollers handy, sacks filled with very fine sand or other fine powdery
material may be used as an alternative to support the cable and
keep it from dragging on the trench bed during the pulling process.
Cable Lubricant
To reduce pulling tensions and damage on cables, lubricants may
be used in conduit. When using cable or pulling lubricants, one
should avoid compounds that may contain oils or greases since
they may damage the cable jackets. Also, pulling lubricants that
contain micro-spheres or micro-balls should be avoided for
medium-voltage cable installations. These kinds of lubricants are
meant to be used on low-tension pulls that are not representative
of power cable pulls.
Most commercially available pulling lubricants can be used with little worry for compatibility. But, one does need to keep in mind that
some pulling lubricants react poorly to some cable jacket compounds, which may lead to ruining the cable jacket. It is best to
avoid damage to the cable jacket by consulting the cable manufacturer regarding lubricant compatibility with specific jacket compounds.
Pulling Eyes & Grips
Pulling eyes attached to the cable conductor(s) are used for large,
heavy cable, or for cables where the pulls are very long or contain
numerous bends. To use the pulling eye, one must fasten it directly
to the conductor(s) on the end of the cable by soldering the copper
conductors into a socket-type eye, or by mechanically compressing
the aluminum conductors into an aluminum eye. Then, a tape seal
or heat-shrinkable tube is placed over the eye-cable joint to provide
a reliable weather-tight seal for the cable during pulling. For armored cables, the armor needs to be properly secured to the eye to
insure the reliability of the cable during pulling. Generally, pulling
eyes tend to be installed at the factory; however, they can also be
installed in the field.
Often times, woven wire pulling grips, generally called baskets
are used to pull armored cables; they are well suited for pulling
smaller size voltage cables, or where the pulls are fairly short. Special measures need to be taken if using baskets on Interlock Armored cables to avoid damage to the cable or problems in making
the pull. The puling grip may tend to stretch the armor if the grip is
not properly secured to the cable. The following method for preparing the cable and attaching the grip is advised:
1. Select the grip size that fits the cable diameter or armor best.
Determine the length of the gripping portion of the grip.
2. Find two points on the end of the cable. The first is 75% of the
grip length from the end; the second is 100% of the grip length
from the end.
3. Get rid of the sheath/armor, and also the outer jacket if there, to
the first mark. Do not damage the core of the armor. If need be,

secure the armor at the cut point with friction tape before cutting.
4. Apply four, 3-inch long, tight wrappings of friction tape. Place
this tape on a) the end of the core, b) on the core to the edge of
the sheath/armor, c) on the jacket, or sheath/armor to the edge
of same, and d) on jacket, or sheath/armor where the last 3
inches of grip will be.
5. If cable will be exposed to moisture during the pull, seal the cut
ends of the conductors with sealing mastic and vinyl tape, or
heat-shrinkable cap(s).
6. Place the grip on the cable and secure it tightly by milking it
from the cable end towards the end of the grip.
7. Clamp the back end of the grip to secure it to the cable with a
steel hose clamp, such as the Band-It types, or a tough steel
wire that is firmly applied.
8. Over the clamp apply a tape wrapping to smooth it and prevent
drag during the pull.
CAUTION: The ends of cable pulled this way will not be entirely
safe from water. If this is an issue, properly applied pulling eyes
should be used.
*NOTE: The force applied by pulling a grip may damage or disrupt
the underlying cable, so it is best to cut off the section immediately below the grip as well as the three feet of cable behind the
grip before fixing together.
Maximum Pulling Tensions
To prevent damage to the cable, pulling tensions for installing electrical cables should be maintained as low as possible. This may be
done through proper use of size ducts or conduits, by avoiding
long pulls, and avoiding runs that may contain sharp bends or severe changes in elevation.
The following maximum allowable pulling tension must not be
passed when pulling cable by the method indicated.
A. Pulling Eye
The maximum tension for cables pulled with a pulling eye should
not exceed the value calculated using the following formula:

Tmax = CTC x CA x N
Where:
Tmax = Maximum pulling tension (lb)
CA = Conductor Area (cmil)
N = Number of conductors being pulled
CTC = Conductor Tension Constant
For CTC with aluminum compression eyes or blots use:
0.011 Copper conductor
0.008 Aluminum Stranded conductor
0.006 Aluminum Solid conductor
For CTC with filled eyes or bolts use:
0.013 Copper conductor
0.011 Aluminum Stranded conductor
0.008 Aluminum Solid conductor
NOTE: When calculating the maximum pulling tension, DO NOT
consider the area of neutral or grounding conductors in cable(s).
The number of conductors should be reduced by one (1) when cal-

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H5
20150116

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
culating the maximum tension for parallel cable assemblies. The
N can equal the number of cables in the assembly, excluding
ground wires. This number can also be reduced by one (1) as an
extra measure.
Pulling Eye Maximum Pulling Tension (lbs)
Size
Copper
1/C
3-1/C
3-1/C
Single Parallel Triplex
8 AWG
181
362
543
7 AWG
229
458
687
6 AWG
288
576
864
5 AWG
363
726
1089
4 AWG
459
918
1377
3 AWG
578
1156
1734
2 AWG
729
1458
2187
1 AWG
920
1840
2760
1/0 AWG
1161
2322
3483
2/0 AWG
1464
2928
4392
3/0 AWG
1845
3690
5535
4/0 AWG
2327
4654
6981
250 kcm
2750
5500
8250
300 kcm
3300
6600
9900
350 kcm
3850
7700 11550
400 kcm
4400
8800 13200
450 kcm
4950
9900 14850
500 kcm
5500
11000 16000
550 kcm
6050 12100 18150
600 kcm
6600 13200 19800
650 kcm
7150 14300 21450
700 kcm
7700 15400 23100
750 kcm
8250 16500 24750
800 kcm
8800 17600 26400
900 kcm
9900 19800 29700
1000 kcm
11000 22000 33000

Stranded Aluminum
1/C
3-1/C
3-1/C
Single Parallel Triplex
132
264
396
166
332
498
209
418
627
264
528
792
333
666
999
420
840
1260
530
1060
1590
669
1338
2007
844
1688
2532
1064
2128
3192
1342
2684
4026
1692
3384
5076
2000
4000
6000
2400
4800
7200
2800
5600
8400
3200
6400
9600
3600
7200 10800
4000
8000 12000
4400
8800 13200
4800
9600 14400
5200 10400 15600
5600
11200 16800
6000 12000 18000
6400 12800 19200
7200 14400 21600
8000 16000 24000

B. Cable Grips
When using a cable grip to pull cables, the maximum tension
should not exceed the value shown in the following two tables, or
the formula used in the table above.
Pulling Grips Maximum Pulling Tension (lbs)
Type of Cable
PE, XLP Insulated EPR Insulated
Single Multiple Single Multiple
Cable Cables
Cable Cables
Unshielded, with or without Jacket 2000 2000
2000 2000
Concentric Wire URD with Jacket
10000 5000
10000 10000
Concentric Wire URD without Jacket 10000 5000
6000 3000
Taped Shielded with Jacket
10000 5000
10000 10000
Fine Wire Shielded with Jacket
10000 5000
10000 10000
LC Shielded with Jacket
8000 4000
5000 2500
Polymeric Armored Cables (See Note 3)

10000 10000
Interlock Armor with PVC Jacket
5000

5000

Interlock Armor with Poly Jacket


5000

5000

Lead Sheathed Cables


See Subsequent Table

Interlock Armor pulling tension using pulling grips should be limited to the
lesser of the value provided above or 50% of value of Tmax calculated using
Pulling Eye formula.

Note 1: The above tensions correspond to three cables in one grip.


The stress on the cable conductor should not exceed 16,000 psi
(0.013 lbs/cmil) for annealed copper conductors when using a grip.
For stranded and full hard aluminum conductors the stress
should not exceed 14,000 psi (0.011 lbs/cmil) and 10,000 psi (0.008
lbs/cmil) for solid to full hard aluminum conductors. The allowable conductor stress should be based on two cables sharing a
load for three single conductor cables in parallel and triplexed configurations.
Note 2: The manufacturer of the cable(s) used should be contacted
to determine the mechanical limitations of the cable(s).
Note 3: It is recommended that pulling grips be used during installation of Polymeric Armored Cables, due to their higher sidewall
bearing pressure capabilities.
Pulling Grips Maximum Pulling Tension (psi)
Type of Cable
PE, XLP Insulated EPR Insulated
Single Multiple Single Multiple
Cable Cables
Cable Cables
Lead Shielded
16000 16000
8000 8000
(Note 4)

(Note 4)

(Note 5)

(Note 5)

Paper Insulated
Single Multiple
Cable Cables
1500 1500
(Note 6)

(Note 6)

Note 4: The maximum pulling tension stress limit for pulling grips
on lead sheathed cable with XMPLE/TRXLPE insulation is 16,000
psi of lead sheath area for a single cable as well as one grip on
three cables (per AEIC CG5-2005).
Note 5: The maximum pulling tension stress limit for pulling grips
on lead sheathed cable with EPR insulation is 8,000 psi of lead
sheath area for a single cable as well as one grip on three cable
(per AEIC CG5-2005).
Note 6: The maximum pulling tension stress limit for pulling grips
on lead sheathed cable with Paper insulation is 1,500 psi of lead
sheath area for a single cable as well as one grip on three cables
(per IPCEA P-41-412-1958).
Sidewall Bearing Pressure (Static Conditions)
The dynamic radial pressure of cable which is pulled around a
bend under pulling tension should be kept as low as possible and
not exceed the following values listed in the table. To calculate
these values use the following formula:

PSW = Te Br
Where:
PSW = Sidewall Bearing Pressure in pounds per foot of bend
radius
Te = Pulling Tension as cable exits the bend (lbs)*
Br = Bend radius, in feet
*Note: The maximum pulling tension determined by the above formulas must be observed.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H6
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable:


Handling and Installation Engineering Guide
Sidewall Bearing Pressure (Dynamic Conditions)
To calculate the minimum bending radii for dynamic conditions,
use the following formula:

MBR = (Te PSW) x 12


Where:
MBR = Minimum Bending Radius (in)
Te = Pulling Tension as cable exits the bend (lbs)*
PSW = Maximum Sidewall Bearing Pressure in pounds per foot
of bend radius from following table
*Note: The maximum pulling tension determined by the above formulas must be observed.
Sidewall Bearing Pressure (lbs/ft of bend radius)*
Type of Cable
PE, XLP
EPR
Insulated
Insulated
Unshielded, without Jacket
1200
500
Unshielded, with Jacket
1200
1000
Interlock Armor with PVC Jacket
Single Conductor & Three Conductor
having round core (100% fillers)
800
800
Interlock Armor with Poly Jacket
Single Conductor & Three Conductor
having round core (100% fillers)
1000
1000
Concentric Wire URD, without Jacket
1200
1000
Concentric Wire, Encapsulating Jacket
2000
2000
Concentric Wire, with Sleeved Jacket
1500
1500
LC Shielded with Jacket
1500
1500
Taped Shielded with Jacket
1500
1500
Fine Wire Shielded with Jacket
1500
1500
Teck-90 Cable, Single Conductor & Three
Conductor having round core (100% fillers) 800
800
Teck-90 Cable, Three Conductor
with minimal or no fillers
350
350
Lead Sheathed (Solid Dielectric)
2000**
2000**
Polymeric Armored Cables Air Bag
2400
AirGuard
3000
Lead Sheath (PILC)
400
Value shown corresponds to a single conductor cable pull. Maximum Sidewall Bearing Pressure limits of 750 and 200 lbs. per foot, respectively, are
recommended for a three-conductor pull.
* For a pulling eye/pulling grip, the maximum pulling tension must be observed in addition to the maximum sidewall bearing pressure limit.
** These values are based on the cross-sectional area of one lead sheath.

Note 1: It is recommended that the manufacturer of the cable(s) in


question be contacted concerning the mechanical limitations of
the cable.

Special Conditions for Metallic Armored Cables


Sheath Currents and Voltages in Single Conductor Cables
A voltage is induced in the concentrically applied wires of the
grounding conductor and the armor in a single conductor cable
with an interlocking armor.
A current will flow in the completed path if the armor and the con-

centric grounding conductor are bonded or grounded at more than


one (1) point. The magnitude of the induced voltage is relative to
the magnitude of the current in the phase conductor. The magnitude of the sheath currents is a function of the induced voltage and
the sheath impedance. The armor and the grounding conductor can
become very hot if the sheath current is large. If this occurs, the
conductor insulation will also be subjected to temperatures that
may cause electrical failure or reduce the life expectancy of the
cable.
One will have to derate the cable if sheath currents are large
enough to raise the temperature of the insulation above its rated
value.
In a single conductor cable carrying currents less than 180 amps,
sheath currents will not pose a problem since induced voltages and
sheath impedances minimize sheath losses.
In single conductor cables carrying currents between 180 and 425
amps, sheath currents will not pose a problem if the cables are
spaced about one (1) cable diameter apart. When this spacing is
done, mutual heating is minimized and the induced voltage is reduced by virtue of field cancellation.
In single conductor cables carrying currents larger than 425 amps,
it is normally necessary to derate the cables to avoid overheating
unless the sheath currents are removed.
Armor of magnetic material (such as galvanized steel) should not
be used on single conductor cables intended for use in AC circuits.
Eliminating Sheath Currents
One needs to make sure that all paths by which sheath currents circulate are kept open in order to prevent the current from flowing.
One should ground and bond cable armors and concentrically applied grounding conductors at the supply end only and afterwards
isolated from ground and each other. Isolation may be established
when installing cables in individual ducts by using cables with PVC
jackets or other insulating materials, or also by mounting cables.
No sheath current will flow if the armors and concentrically applied
grounding conductors are bonded and grounded at the supply end
through a non-ferrous metal panel and mounted on an insulated
panel at the load end. For an illustration of this, please see the figure down below.
a) Cables enter supply end enclosure through metallic non-ferrous
panel to avoid overheating. Cable armors are bonded through
panel.
b) Cable enters load end enclosure through panel of insulating material. The insulating material maintains the open circuit of the
armors.
c) Cable armors and concentrically applied grounding conductors
are bonded and grounded at the supply end only. When installed in this way, the armor and concentric grounding conductor do not form a part of the system ground circuit and a
separate ground conductor should be installed, following the
proper electrical code.
d) All cable connectors and lock nuts are made of non-magnetic
metal (aluminum or other).

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H7
20140401

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
Standing Voltage
An induced voltage will exist between ground and both the armor
and the concentric grounding conductor throughout the length of
the cable when single conductor cables are installed, as shown in
the figure below:

Installation of Single Conductor Cables in Parallel

LOAD
END

SUPPLY
END

Non-Ferrous
Metal Panel

Panel of
Insulating
Materials

Connectors & Locknuts


of Non-Ferrous Material

Separate Ground Conductor


Metal Enclosure

Metallic Shield
Cut-Off Inside
Enclosure Close
to Connector

The magnitude of this voltage is proportional to the phase conductor current, the cable length and the spacing between the cables.
The magnitude of the standing voltage is usually limited to about
25 volts. Please be aware that some Electrical Inspection Authorities limit this voltage to a lower amount.
By grounding the armor and the concentric grounding conductor at
the midpoint of the cable run, one can limit the standing voltage
and also increase the circuit length. If doing this, the cable must go
through a junction box at the midpoint of the run and must be connected on each side of the junction box as shown on the supply
end of the figure above. In this case, the cables at both the supply
and load ends must be connected through panels of insulating material to prevent the flow of sheath currents. Nevertheless, when
two (2) or more single conductor cables are installed in parallel per
phase, grounding at the midpoint is not allowed. For more on installing single conductor armor cables in parallel please see the diagram below, which depicts symmetrical configurations:

Notes:
1. S = Separation of groups. This equals the width of one group.
2. Horizontal and vertical separation between adjacent cables
should be a minimum of one (1) cable diameter to benefit from
the ampacity in free air in a ventilated cable tray.
3. Neutral conductors can be located outside of the above groups.
Reel Capacities
NEMA Method
The formula for calculating footage capacities of reels for round
cable is shown below. A 5% factor and 95% traverse utilization
have been built into the formula. Cables must be wound evenly to
obtain consistency.

{[ (

]}

f
0.95 x C *
A2xXB *
A 2 x X B * ________
F = __ B + ____________ 0.95 x D ____________
1.9 D
12
1.9 D
D

][

][

* Round off the result to the nearest whole number.

Where:
F = Feet of cable on reel
A = Flange diameter, in inches
B = Drum diameter, in inches
C = Inside traverse, in inches
D = Cable diameter, in inches
X = This variable is defined as the distance between the cable
and the outside edge of the reel flange. Clearance is equivalent
to 1 inch or 1 cable diameter, whichever is the larger quantity.
Note: The NEMA formula does not cover paralleled or triplexed assemblies. Contact the cable manufacturer for the maximum
footages of these assemblies.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H8
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable:


Handling and Installation Engineering Guide
Handling of Cables Reels

YES

NO

Reels should be lifted with a shaft extending through both flanges.

Inspect all reels. Reels laying flat should be refused or received


subject to inspection.

Reels should be lowered using hydraulic gate, hoise or forklift.


LOWER CAREFULLY.

Do NOT allow forks to touch cable or reel wrap.

Load with flanges on edge and chock securely..

Never drop reels from trailer.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H9
0140401

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
Shipment for unloading with a forklift at dock

Shipment for unloading down an inclined ramp

Shipment for unloading with a forklift at jobsite

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H10
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable:


Handling and Installation Engineering Guide
Unloading from Open Flat Bed Trailers
Spacer Bar

CORRECT

Reel Tongs

INCORRECT

Winch Line

INCORRECT

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

H11
20140401

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable:


Handling and Installation Engineering Guide
Cable Reel Handling

Do NOT allow forks to touch cable or reel wrap.

Do NOT allow forks to touch cable or reel wrap.

Do NOT allow forks to touch cable or reel wrap.


This method OK for Low Voltage Cable only!

Do NOT allow forks to touch cable or reel wrap.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
H12
20140401

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Jacket Material Selection Chart

Mechanical
Abrasion Resistance
Tensile Strength
Elongation
Compression Resistance
Flexibility
Environmental
Flame
Fresh Water
Salt Water
Motor Oil
Fuel Oil
Crude Oil
Creosote
Gasoline
Kerosene
Isopropyl Alcohol
Wood Alcohol
Grain Alcohol
Sulfuric Acid
Nitric Acid
Hydrochloric Acid
Sodium Hydroxide (Lye)
Potassium Hydroxide (Potash)
Calcium Hydroxide (Lime)
Acetone
Methyl Ethyl Ketone (MEK)
Ethyl Acetate
Lacquer Thinner
Chloroform
Carbon Tetrachloride
Methyl Chloride
General
Leaves protective residue
after combustion
Oxygen index (ASTMD-2863)
Halogen content - % weight
Minimum installation temperature
Dimensional stability underheat
Maximum operating temperature

PVC

Polyethylene

Neoprene

Chlorosulphonated
Polyethylene

Thermoplastic
CP

Good
Excellent
Good
Good
Good

Excellent
Excellent
Excellent
Excellent
Fair

Good
Excellent
Excellent
Excellent
Excellent

Good
Excellent
Excellent
Excellent
Excellent

Excellent
Good
Good
Good
Fair

Good
Good
Good
Good
Good
Good
Poor
Good
Good

Excellent
Excellent
Excellent
Good
Good
Good
Fair
Poor

Excellent
Excellent
Excellent
Good
Good
Good
Fair
Poor

Fair
Fair
Fair
Excellent
Excellent
Excellent
Good
Good
Good
Poor
Poor
Poor
Poor
Poor
Poor
Poor

Poor
Exceptional
Exceptional
Excellent
Slight swelling above 60C
Slight swelling above 60C
Good
Excellent
Slight swelling at
higher temperature
Good
Good
Good
Excellent
Excellent
Excellent
Excellent
Excellent
Excellent
Excellent
Good
Good
Good
Good
Good
Poor

Poor
Fair
Fair
Fair
Excellent
Excellent
Excellent
Good
Good
Poor
Poor
Poor
Poor
Poor
Poor
Poor
Poor

Poor
Good
Good
Good
Excellent
Excellent
Excellent
Excellent
Excellent
Fair
Fair
Fair
Fair
Fair
Fair
Fair
Poor

Good
Excellent
Excellent
Good
Poor above 110C
Poor above 110C
Good
Excellent
Slight swelling at
higher temperature
Good
Good
Good
Excellent
Excellent
Excellent
Excellent
Excellent
Excellent
Good
Good
Good
Good
Good
Good
Poor

Yes
23-30%
26
-10C
Fair
75C

No
17-18%
0
-40C
Fair
75C

Yes
31-39%
18
-20C
Excellent
90C

Yes
30-36%
14
-20C
Excellent
90C

Yes
30-34%
18-20
-40C
Fair
75C

Note: When cables are to be installed in cold weather, they should be kept in heated storage for at least 24 hrs. before installation.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

K
20150309

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

EPR PERFORMANCE SPECIFICATIONS


The insulation shall be a premium quality, heat, moisture, ozone and corona resistanthermosetting ethylene propylene; TYPE I, II or III as
listed in ICEA S-93-639 or ICEA S-97-682. The cable manufacturer shall compound the insulation material with in its own or remotely
owned facilities. The insulation shall be compatible with both the conductor shield and the insulation shield. The thickness shall be at the
100% or 133% level as applicable and in accordance with the latest edition of ICEA.
S-93-639, ICEA S-97-682 and UL 1072. The diameters over the insulation shall be in accordance with ICEA S-97-682. The EPR insulation
shall also meet the guaranteed values as listed in the table below.

PHYSICAL REQUIREMENTS

Unaged

Tensile strength, psi, min.


Elongation at rupture, %, min.
Tensile Stress at 200% elongation, psi, min. at room temperature
Modulus, psi, min. @ 130C

After Air Oven Aging at


121C for 7 days (168 hours)

Hot Creep Test at 150C

Heat Distortion after 1 hour


in air oven at 121C

Ozone Resistance

1600
275
1000
300

Tensile stress, % of unaged value, min.


Elongation at rupture, % of unaged value, min.

90
90

Elongation, %, max.
Set, %, max.

25
5

Percent max.

8.5

0.030% Concentration, 25C, 24 hours


0.0005% Concentration, 52C, 24 hours

No Cracks
No Cracks

-55C

No Cracks

% Max. Distortion of buffed samples of insulation


conditioned for 5 minutes and under load for 15 minutes

No Cracks

Cold Bend
Heat Deformation Test
per ASTM D2220

GUARANTEED
VALUE

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

L
20151015

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

THERMAL RESISTIVITIES OF MATERIALS


Material
Insulating Materials*
Paper insulation in solid type cables
Paper insulation in oil-filled cables
Paper insulation in cables with external gas pressure
Paper insulation in cables with internal gas pressure
A) Pre-impregnated
B) Mass-impregnated
PE
XLPE
PPL
Polyvinyl chloride
Up to and including 3kV cables
Greater than 3kV cables
EPR
Up to and including 3kV cables
Greater than 3kV cables
Butyl rubber
Rubber
Protective Coverings
Compounded jute and fibrous materials
Rubber sandwich protection
Polychoroprene
PVC
Up to and including 35kV cables
Greater than 35kV cables
PVC/Bitumen on corrugated aluminum sheaths
PE
Materials for Duct Installations
Concrete
Fibre
Earthenware
PVC
PE

Thermal Resistivity (T)


Km/W
6.0
5.0
5.5
5.5
6.0
3.5
3.5
5.5
5.0
6.0
3.5
5.0
5.0
5.0
6.0
6.0

5.0
6.0
6.0
3.5
1.0
4.8
1.2
6.0
3.5

*For the purposes of current rating calculations, the semiconducting screening materials are assumed to have the
same thermal properties as the adjacent dielectric materials.
Where plastic or elastomeric materials are used for protective coverings, the thermal resistivities shall be taken to be
the same as those for the insulation grades of the materials given in this table.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

M
20160322

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Guide for the Installation of


ACSR Twisted Pair (TP) Conductor
ACSR/TP overhead conductor consists of two standard concentric stranded ACSR conductors
twisted around each other. It may be installed using techniques and equipment similar to that used
to install other concentric round wire conductors. However, a few special procedures must be used
to maintain equal tension between the two component conductors. The equipment recommendations and special procedures in this guide along with recommendations given in IEEE Std. 524,
Guide to the Installation of overhead Transmission Line Conductors, should be followed.
Handling
It is important to maintain the relationship of the conductor lengths established during manufacturing. Therefore, ACSR/TP conductor should not be rewound in the field from the shipping reel to another reel. Reels containing ACSR/TP conductor should be stored upright, resting on the rims.
Never lay the reel on its side.
Tensioners & Sheaves
Most methods of installation used for standard round conductor can be used to install ACSR/TP
conductor. However, non-tension methods of stringing are preferred such as laying the conductor
out on the ground and then lifting it into position on the poles.
If the conductor must be strung under tension then a multi-groove bullwheel tensioner MUST be
used to install ACSR/TP conductor. A tensioner in which the alignment of the front and back bullwheels are offset by the groove spacing is satisfactory for installing smaller sizes of ACSR/TP conductor, where the conductor will lay flat in the bottom on the groove. If improper equipment is
used, the ridge between the grooves may separate the individual ACSR/TP conductors.
Another commonly used tensioner has one bullwheel tilted slightly in relation to the other. This allows the conductor to ride in the bottom of the grooves. This type of tensioner, when properly sized,
is preferred.
The bottom groove diameters for sheaves and bullwheels should be sized in accordance with IEEE
Std. 524; except that the bottom groove for sheaves should not be less than 14 times the maximum
diameter of the ACSR/TP conductor. Note that for this type of conductor the term Dc should be
twice the diameter of one component conductor (referred to in this guide as the maximum diameter).
The groove radius of the sheave and bullwheel must be wide enough to allow the ACSR/ TP conductor to pass through with the two individual conductors laying flat and parallel. The minimum groove
radius should be 0.55 times the maximum diameter of the ACSR/ TP conductor. The use of smaller
than recommended diameter sheaves and/or high stringing tensions may cause a build-up of torsional stress into the conductor.
Stringing
Each shipping length of ACSR/TP conductor has three metal bands applied at the factory around
both conductors, one band at each end and one approximately 10 feet from the leading end. It is
recommended that these bands not be removed for the stringing procedure, however, if the gripping device cannot be applied, then it is acceptable to remove the outer band only leaving the second band in place a few feet further up the conductor. These bands will help maintain the individual
conductor length relationship when splicing and deadending.
A single woven wire grip sized to fit over both conductors and a swivel link should be used for tension stringing. Double band the open end of the grip to prevent it from accidentally coming off.
Apply tape over the bands to protect the stringing sheave surface.
Tensioning
ACSR/TP conductor should be tensioned by placing a separate grip on each component conductor.
The two grips are connected through a snatch block with a sling. Tension is applied to the snatch
block with a hoist or other appropriate tensioning device. This arrangement will apply even tension
to the component conductors.
Splicing
ACSR/TP conductors are normally joined by separately splicing each component conductor. Where
possible, the individual conductor splices should be staggered about 5 feet. An additional twist may
be needed before the second splice is made to remove any looseness between the individual conductors. This will ensure that each component conductor carries an even share of line tension. Both
splices must be made before tension is applied.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

J
20150202

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Guide for the Installation of


ACSR Twisted Pair (TP) Conductor
Repairs
Repairs to a damaged component conductor can be made using the following procedure:
1. Attach two wire grips facing each other approximately 15 feet apart on the undamaged component conductors.
2.Attach a hoist to the grips and take up tension. As the tension increases, slack will appear in
the damaged conductor.
3.Increase tension until there is enough slack to make the repairs.
If it is necessary to cut the damaged conductor to install a splice, a second set of grips and
hoist must be installed on the damaged conductor before it is cut. The above procedure should
be followed to install the grips.
Helically applied rods may also be used for repairs in accordance with normal utility practice
given the nature and severity of damage. Follow the above procedures to install the repair rods
on the damaged conductor.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
J
20150202

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable


Methods of Color Coding
Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by different manufacturers.
The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for
ease and convenience, ink printed versions were developed.
Telephone requirements established special color codes.
Color Codes (ICEA Methods)
ICEA/NEMA Method 1
Colored insulation with contrasting ink tracers as required. Six
different insulation colors and four different colored ink tracers are used to provide positive identification through 21 conductors. The same identification sequence is repeated for
cables containing more than 21 conductors.
ICEA/NEMA Method 2
A neutral colored compound is used with single or double spiral ink tracers as required to provide positive identification
through 21 conductors. The identification sequence is repeated
for cables containing more than 21 conductors.
ICEA/NEMA Method 3
A neutral or single colored insulation compound is surface ink
printed with both conductor number and color designation to
provide positive identification through 21 conductors. The
identification sequence is repeated for colors containing more
than 21 conductors.
ICEA/NEMA Method 4
A neutral or single colored insulation compound is surface ink
printed with conductor number to provide positive conductor
identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

ICEA/NEMA Method 5
A color coding using braids. Also sometimes specified using
colored insulation and contrasting tracers as an extension of
Method I to eliminate duplicate conductors. Up to 127 positive
conductor coding are available with this method. Usually
specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table
5-2.
ICEA/NEMA Method 6
A color coding whereby one conductor in each layer is identified by a braid, tape, ridge, stripe or color.
ICEA/NEMA Paired Color Code
A coding whereby one leg of all pairs is coded white and its
mate is coded in accordance with the first 21 conductors of
Method 1, omitting white and repeating the sequence as necessary.
Telephone Paired Color Code
Five colors are paired with each of five mate colors to give 25
identified pairs. The color sequences are repeated for more
than 25 pairs using colored binder strings for group identification.

Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is
ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

B
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Color Coding Charts
ICEA Method 1, Table E-1

ICEA Method 1, Table E-2

(Colored compound with tracers)

(Colored compound with tracers)

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Background
or Base Color
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange

Tracer
Color

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green

*This conductor is in the inside of the assembly.

ICEA Method 2, Table E-1


(Neutral colored compound with tracers)

Conductor
Number

1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

First
Tracer
Color
(Wide
Tracer)
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange

Second
Tracer
Color
(Narrow
Tracer)

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green

*This conductor is in the inside of the assembly.

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Background
or Base Color
Black
Red
Blue
Orange
Yellow
Brown
Red
Blue
Orange
Yellow
Brown
Black
Blue
Orange
Yellow
Brown
Black
Red
Orange
Yellow
Brown
Black
Red
Blue
Yellow
Brown
Black
Red
Blue
Orange
Brown
Black
Red
Blue
Orange
Yellow

Tracer
Color

Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Brown
Brown
Brown
Brown
Brown

*This conductor is in the inside of the assembly.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable


Color Coding Charts
ICEA Method 1, Table E-2

ICEA Method 3

ICEA Method 4

(Neutral colored compound with tracers)

(Neutral or single color compound with surface


printing of numbers and color designations)

(Neutral or single color compound with surface


printing of numbers)

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Conductor
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Background
or Base Color
Black
Red
Blue
Orange
Yellow
Brown
Red
Blue
Orange
Yellow
Brown
Black
Blue
Orange
Yellow
Brown
Black
Red
Orange
Yellow
Brown
Black
Red
Blue
Yellow
Brown
Black
Red
Blue
Orange
Brown
Black
Red
Blue
Orange
Yellow

Tracer
Color
Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Brown
Brown
Brown
Brown
Brown

Printed Legend
1 Black
2 White
3 Red
4 Green
5 Orange
6 Blue
7 WhiteBlack
8 RedBlack
9 GreenBlack
10 OrangeBlack
11 BlueBlack
12 BlackWhite
13 RedWhite
14 GreenWhite
15 BlueWhite
16 BlackRed
17 WhiteRed
18 OrangeRed
19 BlueRed
20 RedGreen
21 OrangeGreen

*This conductor is in the inside of the assembly.

Printed Legend
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

*This conductor is in the inside of the assembly.

*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

B
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Color Coding Charts
ICEA Method 5
(Colored compounds with tracers)

Cond.
Number
1*
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Background
or
Base Color
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange
Black
White
Orange
Blue
Red
Orange
Black
White
Red
Green
Orange
Blue
Black
White
Orange
White
Black
White
Red
Green
Orange
Blue

First
Tracer
Color

Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green
White
Black
Black
Black
Black
Black
Red
Red
Black
Black
Black
White
White
Red
White
Red
White
Black
White
White
Red
Red

Second
Tracer
Color

Red
Red
White
White
White
White
Green
Green
Green
Orange
Green
Orange
Orange
Orange
Blue
Blue
Green
Green
Green
Blue
Green
Green

Cond.
Number
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86

Background
or
Base Color
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
White
Red
Green
Orange
Blue
Black
Red
Green
Orange
Blue
Red
Green
Blue
Orange
Green
Black
White
Blue

First
Tracer
Color
White
Black
White
Orange
Red
Red
Orange
Black
Orange
Red
Black
Black
Orange
Orange
Orange
Black
Green
Green
Red
Orange
Black
Orange
White
White
Green
Green
Green
White
Red
Red
Orange
Orange
Red
White
White
White
White
Black
White
Red
Green
Green
Green

Second
Tracer
Color
Blue
Blue
Blue
Red
Blue
Orange
Red
Orange
Black
Blue
Blue
Orange
Green
Green
Green
Blue
Blue
Orange
Blue
Blue
Blue
Blue
Red
Red
Blue
Blue
Blue
Red
Black
Black
Blue
Blue
Black
Green
Green
Orange
Orange
Green

Cond.
Number
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

Background
or
Base Color
Black
White
Red
Green
Blue
Black
White
Red
Green
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Black
White
Red
Green
Orange
Blue
Black
White
Green
Orange
Blue
Black
Red
Green
Orange
Blue
Black
White
Red
Orange
Blue
Black
White
Red

First
Tracer
Color
Orange
Orange
Orange
Orange
Orange
Blue
Blue
Blue
Blue
Blue

Black
White
Red
Green
Orange
Blue
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow

Second
Tracer
Color

Red
Red
Red
Red
Red
White
White
White
White
White
Green
Green
Green
Green
Green
Blue
Blue
Blue

*This conductor is in the inside of the assembly.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Recommended Reel Handling Practices


How to Handle Cable Reels

Recycling/Reel Return
Broken Reel Extreme Makeover Program
Innovative solution to salvage broken reels
with good cable on it. Reels are picked up,
examined and reran on new reels, avoiding
scrapping expensive wire.
Empty Wooden Reels Recycled program
AWG continuously picks up empty wooden
reels at no cost. This eliminates labor and
time to breakdown reels, as well as refuse
costs.

Cradle both reel flanges between


forks.

Upended heavy reels will often arrive


damaged. Refuse or receive subject
to inspection for hidden damage.

Reels can be hoisted with a shaft


extending through both flanges.

Do not lift by top flange. Cable


or reel will be damaged.

Lower reels from truck using


hydraulic gate, hoist or fork lift.
LOWER CAREFULLY!

Never allow forks to touch


cable surface or reel wrap.

Always load with flanges on


edge and chock and block
securely.

Never drop reels.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

C
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

NOTES

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Steel Reel Specifications


I-Beam Tire Fluted Steel ReelType RMT
NOTE When required, cable test hole in the flange shall not have more than 3 flutes removed to provide this opening. The cable test hole shall be reinforced along the cutout with a metal equal to or greater than that required for use in the drum of the reel. Height of cable test hole to be no greater than onehalf the length.

30
TRAVERSE

1 RADIUS
LAG OPENING

FLANGE
DIAMETER

DRUM
DIAMETER

THE LAG OPENING SHOULD


BE WELL ROUNDED AND
GROUND SMOOTH

TIRE

HEAD SHEET

DRUM

INNER RING
ARBOR HOLE
FLUTES LONG CROSS ARM
SHORT CROSS ARM

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

D
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Steel Reel Specifications


General Purpose Steel Fluted Returnable Reels for Wire and CablesClass 1
Type*

Reel Dimensions Max. Arbor Max.


Fl
Trav Drum Overall Hole Number
Width Diameter Flutes
(in)
(in)
per Hd

RM
42
RM
48
RM
54
RM
60
RM
66
RM
72
RM
72
RM
78
RMT
84
RMT
84
RMT
84
RMT
90
RMT
90
RMT
90
RMT
96
RMT
98
RMT** 108

24
24
32
32
32
36
36
36
36
45
45
45
45
54
60
60
74

24
24
32
32
36
40
48
48
42
42
56
42
56
56
42
56
56

33
33
41
41
41
45
45
45
45
55
55
55
55
64
71
71
85

3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25

24
24
30
30
32
40
40
40
40
40
40
40
40
40
40
40
40

Tire
Size
(in)

2x5/16
2x5/16
2x5/16
2x5/16
2-1/2x1/2
2-1/2x1/2
2-1/2x1/2
2-1/2x5/8
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam
7.5lb/ft, 3" I-Beam

Cross Arms
U.S.S. Long
Short
(ga)
(in)
(in)

8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

5x2
5x2
5x2
5x2
6x2
6x2
6x2
6x2
7-7/8x2
7-7/8x2
7-7/8x2
7-7/8x2
7-7/8x2
7-7/8x2
7-7/8x3
7-7/8x3
7-7/8x3

4x2
4x2
4x2
4x2
5x2
5x2
5x2
5x2
6x2
6x2
6x2
6x2
6x2
6x2
6x3
6x3
6x3

Drum
U.S.S.
(ga)

12
12
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8

Inner
(Flange)
Maximum
Ring
Head
Capacity
Dimensions Sheet
(lb)
(kg)
(in)
U.S.S.
(ga)
3-3/4x3/16
3-3/4x3/16
3-3/4x3/16
3-3/4x3/16
3-3/4x3/16
3-3/4x1/4
3-3/4x1/4
3-3/4x1/4
4x1/4
4x1/4
4x1/4
4-1/4x1/4
4-1/4x1/4
4-1/4x1/4
4-1/2x5/16
4-1/2x5/16
4-1/2x5/16

16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14

1,956
887
3,072
1,393
4,464
2,024
6,360
2,884
7,680
3,482
10,260 4,654
7,872
3,570
10,752 4,876
13,608 6,171
17,004 7,711
11,196 5,050
21,036 9,540
15,216 6,900
18,252 8,277
26,000 11,719
26,000 11,719
30,000 13,605

* RMFlat bar tire


** Generally used for aluminum wire and cable
Alternate size is 3x1/2 inch
RMTI-Beam Tire
NOTETie holes, if necessary, shall be in the flat portion of the head sheet. There will be no holes in the flute itself.
NOTEA range of 3 to 3.25-inch and 5 to 5.25-inch arbor hole diameter shall be permitted for existing reels until the year 2005.

Welding Requirements for Class 1 Reels


Head sheet to tireat all radii of flute-intermittent weld
Head sheet to inner ringat all radii of flute-intermittent weld
Drum to inner ringintermittent weld
Cross arm to cross armcontinuous weld
Cross arm to inner ringcontinuous weld
Cross arm to hubcontinuous weld
Back-up plate to hub and cross armcontinuous weld
Port framecontinuous weld
All welds shall reflect good welding practice with proper penetration.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
D
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Cabling

Cable A

1500' linear

Cable B

1500' linear

A 1500' linear
B 1500' linear
C 1500' linear
4500' linear

Cable C

1500' linear

4500' linear

Cabled (Triplexed) Cables


Cable A

1500' linear

Cable B

1500' linear

Cable C

1500' linear

CKT

1350' linear

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

I
20140506

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Metric Size to AWG Size


Area
(mm2)

Size
AWG/MCM

Nominal
Overall
Diameter
(mm)

Nominal
Overall
Diameter
(in)

Number
of Wires

Area
(mm2)

Size
AWG/MCM

Nominal
Overall
Diameter
(mm)

Nominal
Overall
Diameter
(in)

Number
of Wires

1010
1000
887
800
760
633
507
500
400
380
304
300
253.4
240
203
185
177
152
150
127
120
107.2
95
85.01
70
67.43
53.49
50

2000

41.45
41.14
38.76
36.81
35.87
32.74
29.26
29.05
25.97
25.35
22.68
22.46
20.65
20.09
18.49
17.64
17.30
16.00
15.85
14.61
14.15
13.41
12.60
11.94
10.86
10.64
9.47
9.15

1.632
1.620
1.526
1.448
1.412
1.289
1.152
1.143
1.023
0.998
0.893
0.884
0.813
0.792
0.728
0.695
0.681
0.630
0.624
0.575
0.558
0.528
0.497
0.470
0.427
0.419
0.373
0.361

127
91
127
61
91
91
61
37
37
61
61
37
37
37
37
37
37
37
19
37
19
19
19
19
19
19
19
19

42.41
35
35
33.62
26.67
25
21.15
16
13.30
10
8.37
6.0
5.26
4.0
3.31
2.5
2.08
1.5
1.31
1.0
0.82
0.75
0.52
0.50
0.33
0.25
0.20

8.43
7.65
7.56
7.42
6.61
6.39
5.89
5.13
4.67
4.05
3.71
3.12
2.95
2.55
2.34
2.01
1.85
1.56
1.47
1.29
1.02
0.98
0.81
0.80
0.64
0.56
0.51

0.332
0.302
0.298
0.292
0.260
0.252
0.232
0.202
0.184
0.160
0.146
0.123
0.116
0.101
0.092
0.080
0.073
0.062
0.058
0.051
0.046
0.039
0.032
0.031
0.025
0.022
0.020

19
19
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1750
1500
1250
1000

750
600
500
400
350
300
250
4/0
3/0
2/0
1/0

2
3
4
6
8
10
12
14
16
18
20
22
24

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

E
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

NOTES

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Copper Conductor Stranding Chart


Class A thru M
Size
AWG

36
35
34
33
32
30
30
29
28
27
26
25
24
23
22
21
20
18
16
14
12
10
9
8
6
4
3
2
1
1/0
2/0

Concentric
Strand
Class A

Concentric
Strand
Class B

Concentric
Strand
Class C

Concentric
Strand
Class D

Rope
Lay
Concentric
Strand
Class G

Rope
Lay
Concentric
Strand
Class H

Rope
Lay
Bunch
Strand
Class I
24AWG
(.201")

Rope
Lay
Bunch
Strand
Class M
30AWG
(.010")

Rope
Lay
Bunch
Strand
Class K
34AWG
(.0063")

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7
7

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7
7
7
7
7
7
7
7
19
19
19

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
19
19
19
19
19
19
19
19
19
19
19
19
37
37
37

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
37
37
37
37
37
37
37
37
37
61
61
61

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
49
49
49
49
49
49
49
49
49
133
133
133

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
133
133
133
133
133
133
259
259
259

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
26
N/A
41
63
105
N/A
161
210
266
342

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10
16
26
41
65
104
N/A
168
266
420
532
665
836
1064
1323

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
26
41
65
104
186
259
N/A
420
665
1064
1323
1666
2107
2646
3325

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

G
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

NOTES

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Glossary of Terms
AWG
Abbreviation for American Wire Gauge.
AWM
Designation for appliance wiring material.
Alternating Current
Electric current that continually reverses its direction. Is expressed in cycles per second (hertz or Hz).
Ambient Temperature
The temperature of the medium (gas, liquid or earth) surrounding an object.
American Mustang
A premium grade thermoset cord, UL listed as SOOW or
SJOOW, CSA SOOW and SJOOW.
American Wire Gauge (AWG)
A standard system for designating wire diameter. Also referred to as the Brown and Sharpe (B&S) wire gauge.
Ampacity
See Current Carrying Capacity.
Ampere
The unit of current. One ampere is the current flowing through
one ohm of resistance at one volt potential.
Anneal
Relief of mechanical stress through application of heat and
gradual cooling. Annealing copper renders it soft and less brittle.
Audio Frequency
The range of frequencies audible to the human ear. Usually
2020,000 Hz.
Braid
A fibrous or metallic group of filaments interwoven in cylindrical form to form a covering over one or more wires.
Breakdown Voltage
The voltage at which the insulation between two conductors
breaks down.
Bunch Stranding
A group of wires of the same diameter twisted together without a predetermined pattern.
Cabling
The twisting together of two or more insulated conductors to
form a cable.
Capacitance
The ability of a dielectric material between conductors to store
electricity when a difference of potential exists between the
conductors. The unit of measurement is the farad, which is the
capacitance value that will store a charge of one coulomb
when a one-volt potential difference exists between the conductors. In AC, one farad is the capacitance value that will permit one ampere of current when the voltage across the
capacitor changes at a rate of one volt per second.
Circuit (Electric)
The complete path of an electrical current. When the continuity is broken, it is called an open circuit; when continuity is
maintained, it is called a closed circuit.
Cold Flow
Permanent deformation of the insulation due to mechanical
force or pressure (not due to heat softening).

Color Code
A system for circuit identification through use of solid colors
and contrasting tracers.
Compound
An insulating or jacketing material made by mixing two or
more ingredients.
Concentricity
In a wire or cable, the measurement of the location of the center of the conductor with respect to the geometric center of
the surrounding insulation.
Conductor
An uninsulated wire suitable for carrying electrical current.
Contacts
The parts of the connector that actually carry the electrical current and that touch the equivalent parts in the mating connector.
Continuity Check
A test to determine whether electrical current flows continuously throughout the length of a single wire or individual
wires in a cable.
Cord
A flexible insulated wire suitable for carrying electric current.
Corona
Ionization of air surrounding a conductor caused by the influence of high voltage. Causes deterioration of insulation materials.
Crazing
The minute cracks on the surface of plastic materials.
CSA
Abbreviation for Canadian Standards Association, a nonprofit,
independent organization that operates a listing service for
electrical and electronic materials and equipment. The Canadian counterpart of the Underwriters Laboratories
Current Carrying Capacity
The maximum current an insulated conductor can safely carry
without exceeding its insulation and jacket temperature limitations. It is dependent on the installation conditions.
Decibel (db)
A unit that expresses differences of power or voltage level. It
is used to express power loss in passive circuits or cables.
Dielectric Strength
The voltage that an insulation can withstand before breakdown occurs. Usually expressed as a voltage gradient (such as
volts per mil).
Direct Capacitance
The capacitance measured directly from conductor to conductor through a single insulating layer.
Drain Wire
In a cable, the uninsulated wire laid over the shield component or components and used as a ground connection.
Drawing
In wire manufacture, pulling the metal through a die or series
of dies to reduce diameter to a specified size.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

F
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Glossary of Terms
Eccentricity
Like concentricity, a measure of the center of a conductor's location with respect to the circular cross section of the insulation. Expressed as a percentage of displacement of one circle
within the other.
Elongation
The fractional increase in length of a material stressed in tension.
EMI
Abbreviation for electromagnetic interference.
Farad
A unit of electrical capacitance.
Filler
1) A material used in multiconductor cables to occupy large interstices formed by the assembled conductors;
2) An inert substance added to a compound to improve properties or decrease cost.
Flame Resistance
The ability of a material to resist the propagation of flame
once the heat source is removed.
Flex Life
The measurement of the ability of a conductor or cable to
withstand repeated bending.
Frequency
The number of times an alternating current repeats its cycle in
one second.
G
An industry designation for a 2kV portable power cable consisting of 2 4 insulated conductors with ground wires placed
in the valleys for use in mines and similar applications.
Gauge
A term used to denote the physical size of a wire.
G-GC designation
An industry for a 2kV portable power cable consisting of 3 insulated conductors with 2 ground wires, and a ground check
conductor. For use in mines and similar applications.
Ground
An electrical term meaning to connect to the earth or other
large conducting body to serve as an earth, thus making a
complete electrical circuit.
Harness
An arrangement of wires and cables, usually with many breakouts, which have been tied together or pulled into a rubber or
plastic sheath, used to interconnect an electric circuit.
Hertz (Hz)
A term replacing cycles per second as an indication of frequency.
Hi-Pot
A test designed to determine the highest voltage that can be
applied to a conductor without breaking through the insulation.
HPD
Heater cord with thermoset insulation and cotton or rayon
braid overall.
HPN
Parallel heater cord.

Hz
Abbreviation for hertz.
Impedance
The total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. It is a combination of resistance R and reactance X,
measured in ohms.
Inductance
The property of a circuit or circuit element that opposes a
change in current flow, thus causing current changes to lag behind voltage changes. It is measured in henrys.
Insulation
A material having high resistance to the flow of electric current. Often called a dielectric in radio frequency cable.
Jacket
An outer non-metallic protective covering applied over an insulated wire or cable.
Jumper Cable
A short flat cable interconnecting two wiring boards or devices.
Lay
The length measured along the axis of a wire or cable required for a single strand (in stranded wire) or conductor (in
cable) to make one complete turn about the axis of the conductor or cable.
Longitudinal Shield
A tape shield, flat or corrugated, applied longitudinally with
the axis of the core being shielded.
MTW
Thermoplastic insulated machine tool wire.
Multiconductor
More than one conductor within a single cable complex.
Mylar
A synthetic compound with high dielectric qualities made by
DuPont and used extensively in the wire and cable industry in
tape form.
NEMA
Abbreviation for National Electrical Manufacturers Association.
Ohm
A unit of electrical resistance.
OSHA
Abbreviation for Occupational Safety and Health Act, specifically the Williams Steiger Law passed in 1970 covering all factors relating to safety in places of employment.
Plasticizer
A chemical agent added to plastics to make them softer and
more pliable.
Potting
The sealing of a cable termination or other component with a
liquid that cures into an elastomer.
Primary Insulation
The first layer of nonconductive material applied over a conductor, whose prime function is to act as electrical insulation.

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
F
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

Wire & Cable


Glossary of Terms
Put-Up
Packaging of finished wire or cable by size and length.
PVC
Abbreviation for polyvinylchloride.
Rated Voltage
The maximum voltage at which an electrical component can
operate for extended periods without undue degradation or
safety hazard.
REA
Abbreviation for Rural Electrification Administration, which is
part of the US Dept. of Agriculture. REA establishes specifications and provides approval for telephone station wire and
power cables.
Resistance
A measure of the difficulty in moving electrical current
through a medium when voltage is applied. It is measured in
ohms.
RFI
Abbreviation for radio frequency interference.
S
Heavy duty, rubber insulated portable cord. Standard copper
conductors with separator and individual rubber insulation.
Two or more color-coded conductors cabled with filler,
wrapped with separator and rubber jacketed overall 600V.
SEO
Same construction as STO, except insulation and jacket are
made of Thermoplastic Elastomer Rubber (TPE) 600V.
SEOOW
Same construction as SEOW, except with oil resistant insulation.
SEOW
Same construction as SEO, except suitable for outdoor use.
Usually UL listed for continuous submersion in water 600V.
Separator
Pertaining to wire and cable, a layer of insulating material
such as textile paper, Mylar, etc., which is placed between a
conductor and its dielectric, between a cable jacket and the
components it covers, or between various components of
multiple conductor cable. It can be utilized to improve stripping qualities and/or flexibility, or can offer additional mechanical or electrical protection to the components it separates.
Shield
A tape shield, or braid of metal, usually copper, aluminum or
other conducting material, placed around or between electric
circuits or cables or their components to contain any unwanted radiation, or to keep out an unwanted interference.
SJ
Junior hard service rubber insulated pendant or portable cord.
Same construction as SJT, except insulation and jacket is thermoset (rubber) 300V.
SJE
Same construction as SJT, except insulation and jacket made
of Thermoplastic Elastomer Rubber (TPE)300V.
SJEO
Same construction as SJO, except insulation and jacket made
of Thermoplastic Elastomer Rubber (TPE).

SJEOW
Same construction as SEOW except 300 volt rated.
SJO
Same as SJ, but oil resistant outer jacket. Can also be made
water resistant. 300V, 60C, 75C, 900C or 105C.
SJOOW
Same as SOOW except 300 volt rated.
SJT
Junior hard service thermoplastic conductors with overall
thermoplastic jacket, 300V, 60C, 75C, 900C or 105C.
SJTO
Same as SJT, but oil resistant thermoplastic outer jacket.
SLC
Stage Lighting Cable. A 600-volt single conductor cable for
use with indoor and outdoor stages, fairs and carnivals.
SO
Hard service cord. Same construction as type S, except oil resistant thermoset jacket. 600V, 600C to 105C.
SOOW
Same as SOW except oil resistant insulation.
SOW
Same as SO except suitable for outdoor use.
SP-1
All rubber, parallel jacketed, two conductor light duty cord for
pendant or portable use. 300V.
SP-2
Same as SP-1, but heavier construction, with or without third
conductor for grounding purposes. 300V.
SP-3
Same as SP-2, but heavier construction for refrigerators or
room air conditioners. 300V.
Spacing
Distance between the closest edges of two adjacent conductors.
Spark Test
A test designed to locate pinholes in the insulation of a wire or
cable by application of a voltage for a very short period of
time while the wire is being drawn through a field of electrodes.
SPE
Same construction as SP-1, except insulation and jacket made
of Thermoplastic Elastomer Rubber (TPE).
Spiral Wrap
The helical wrap of a tape or other material over a core or
component.
SPT-1
Same as SP-1, except all thermoplastic, 300V. With or without
third conductor for grounding.
SPT-2
Same as SP-2, except all thermoplastic. 300V. With or without
third conductor for grounding.
SPT-3
Same as SP-3, except all thermoplastic. 300V. With or without
third conductor for grounding.

www.buyawg.com
TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.

F
20140110

APPENDIX

Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com

Wire & Cable


Glossary of Terms
ST
Hard service cord, jacketed. Same as type S, except all plastic
construction. 600V, 600C to 105C.
STO
Same as ST, but with oil resistant thermoplastic outer jacket.
600V, 600C to 105C.
Strand
A single uninsulated wire.
Stranded Conductor
A conductor composed of wires or groups of wires twisted together.
Surge
A temporary and relatively large increase in the voltage or current in an electric circuit or cable. Also called a transient.
SV
Vacuum cleaner cord, rubber insulated with rubber jacket,
rated at 300V.
SVE
Same construction as SV, except insulation and jacket made of
Thermoplastic Elastomer (TPE).
SVT
Same as SV, except all plastic construction. With or without
third conductor for grounding purposes only. 300V, 600C to
105C.
TC
Tray Cable. Multi-conductor cable specifically approved for
use installed in cable trays.
Tensile Strength
The pull stress required to break a given specimen.
Thermoplastic
A material that softens and melts when heated and becomes
firm on cooling.

Thermoset
A material that hardens or sets when heat is applied and that,
once set, cannot be resoftened by heating. The application of
heat cures or vulcanizes the material.
TPE
Abbreviation for Thermoplastic Elastomer.
UL
Abbreviation for Underwriters Laboratories, a nonprofit independent organization that operates a listing service for electrical and electronic materials and equipment.
Voltage
The term most often used in place of electromotive force, potential, potential difference or voltage drop to designate the
electrical pressure that exists between two points and is capable of producing a current when a closed circuit is connected
between two points.
VW-1
A flammability rating established by Underwriters Laboratories for wires and cables that pass a specific vertical flame
test, formerly designated FR-1.
W (Type)
An industry designation for a 2kV portable power cable consisting of 16 insulated conductors. For use in mines and similar severe duty applications.
W
UL designation for outdoor listed flexible cord that is tested
for sunlight and weather requirements (e.g., 5TW).
Water Resistant
UL designation for cords that have an insulation on the individual conductors that passes UL requirements (e.g., 5T Water
Resistant or 5T Dry 105C, Water Resistant 60C).

www.buyawg.com
APPENDIX

TOLL FREE 1.800.342.7215


Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
F
20140110

Information on this sheet subject to change without notice.


Copyright 2016, American Wire Group, Inc.