I. Safety precautions

Table of Contents

The following contents are stated on the product and the operation
manual, including usage, precautions against personal harm and
property loss, and the methods of using the product correctly and safely.
After fully understanding the following contents (identifiers and icons),
read the text body and observe the following rules.

I. Safety precautions......................................................................................... 1

OPERATION

This manual gives detailed description of the precautions


that should be brought to your attention during operation.

MANUAL

In order to ensure correct service of the wired controller


please read this manual carefully before using the unit.

III. Installation and configuration instruction...................................................... 4


IV. Webpage instruction of the Master computer............................................ 24
V. iPhone app instruction.................................................................................31

Identifier description
Identifier

VI. iPad app instruction....................................................................................34


VII. Android App Instructions...........................................................................38

For convenience of future reference, keep this manual


after reading it.

Data Converter Operation Manual

II.System introduction of the data converter..................................................... 2

Warning

VII.Technical indicators and requirements...................................................... 43

Usage
Warning

Meaning

Warning

Means improper handling may lead to


personal death or severe injury.

Caution

Means improper handling may lead to


personal injury or property loss.

Forbid

Do not operate with wet hands or let water enter the wire
controller. Otherwise, electric shock may occur.

Meaning
It indicates forbidding. The forbidden subject-matter is
indicated in the icon or by images or characters aside.
It indicates compulsory implementation. The compulsory
subject-matter is indicated in the icon or by images or
characters aside.

2. System structure diagram

III. Installation and configuration instruction

CCM15

XYE
Laptop
Laptop

Internet

LAN

Router

F1 F2 E

Indoor units

CCM30

LED
colour

Running
status

485

Green

Flash

Flashing when 485


communication is normal

IP

Green

Flash

Flashing when Ethernet


connecting is normal

POWER

Yellow

Constantly
light

Constantly light after


powering on

Hardware instruction

Cloud Servers

PC

Indicator
light

Pad

Status indicator light

Fig.2.1 Schematic diagram of connecting the indoor unit through


CCM03 to the central air-conditioning system.

CCM15

XYE
Laptop
Laptop

Router

LAN

F1 F2 E

Internet

Iphone

Connect to the
Ethernet
communication
terminal

Outdoor units

Pad

Data
converter

Installation
operation
manual

b. WEB system functions achieve


webpage visiting to the
multi-connected system, including
air-conditioner status browsing,
air-conditioner control, and system
settings.

Power
adaptor
Wiring
3-terminal
and 1
bags of
fixed
screws

CCM30

Optional

Fig.2.2

Name

c. Please follow the installation manual


to operate and assembling according
to the following steps strictly. The
manufacturer assumes no
responsibility or liability for any
equipment damage caused by
personal maloperations.

Cloud Servers

PC

Instruction

a. Data converter which equips


WEB/HTTP/TCP/IP functions
provides convenience and efficiency
to users for visiting LAN/WAN and
remote accesses to Midea
multi-connected central
air-conditioning system.

Max.64

Optional

Iphone

Instruction

NOTE
If theres no XYE communication terminals in the indoor unit PCB,
connect it to XYE communication terminals in the outdoor unit .

Fig.3.2

Fig.3.1 Structure dimension drawing

IP 192.168.1.201, subnet mask 255.255.255.0 is not in the same segment as IP


172.10.4.120, subnet mask: 255.255.255.0 Input ipconfig /allin CMD and press Enter

Connect the data converter to the transformer or router to debug after we confirm the
Default Gateway and Subnet Mask in the LAN
B. Configure the data transformer IP address
If IP address segment of the device is the same as that of the PC, this configuration
is unnecessary then. Directly enter into C step: static IP address configuration.
Otherwise the IP address needs to be changed.
Firstly, connect the device to a computer. Theres no need to go through the
transformer or router. If theres one, please unplug the cable to the computer firstly
,and then connecting as the figure shown below (cross line).Connect the device with
PC by cross line only.

Check IP address information here in this LAN

When finishing connecting the device,


enter into Network and Internet . Click
Network and Sharing Connection to
enter Local Area Connection Properties , as shown in the figure :

When entering the Local Area Connection Properties, double click Internet
protocol Version4(TCP/IPv4) or click
Properties to enter into Internet
protocol Version4(TCP/IPv4)properties
dialogue. Choose Use the following IP
address

2.Take the data converter out and power


it on to see if the device is normal
( POWER indicator lights up)

POWER indicator lights up


Fig.3.3

Debugging as the following steps


A. Device address instruction
Initial address of the data converter is
192.168.1.200. To avoid address
conflict, check if theres the address in
LAN before accessing the device.
Open CMD interface and input ping
192.168.1.200.

4. Access the master computer and


debugging
Use cables to connect the data
converter to a router or a transformer
and connect the router or the
transformer to a PC. Electrify the
adaptor and debug after it can be
electrified normally.IP address of the
data converter is http//192.168.1.200.

Fig.3.8

Fig.3.7
We can see the Default
Gateway is our default
gateway: 10.46.4.1,
Subnet Mask is the
subnet mask:
255.255.255.0. Thus, we
need to change our device
IP address to this
segments IP address,
such as:
Change IP address to
10.46.4.100
Change Subnet Mask to:
255.255.255.0

As shown in the figure, choose Use the following IP address(s) and input
192.168.1.xxx in IP address, xxx ranging from 0 to 255. Dont input 200; Input
255.255.255.0 in the Default Gateway. Click OK after finishing configuring and log off.

When finishing configuring the IP address, open IE browser and input 192.168.1.200
to enter into the WEB page of the data converter, as shown in the figure:

Fig.3.11

10

When entering the Local Area Connection Properties, double click Internet
protocol Version4(TCP/IPv4) or click Properties to enter into Internet protocol
Version4(TCP/IPv4)properties dialogue. Choose Use the following IP address

11

DATA
with CCM03-0

10.46.4.100

IP address: having found IP


address in step A, input a
different address that dont
conflict with the host and
device in the same segment ,
such as 10.46.4.75

10.46.4.100
202.104.30.246
xxxx

After finishing setting click Download settings. After completing the


settings manually restart. Note:
Please take care of your IP address
and avoiding forgetting.

Fig.3.16
Fig.3.14

13

14

1. Enter http:// www.imdv.com.cn to apply an ID.

6. Enter into the webpage


After connecting to the multi-connected system, it will enter into the project WEB
page. Input http://XXX.XXX.XXX.XXX(Data converter IP address) which is being set
in the previous steps in the browser. Refresh the page to see if it has connected to
the unit.

Connect the device to 485 communication wire after device settings(Refer to the
schematic diagram). Pay attention to A2,B2,E terminals have been connected to XYE
terminals of the central air-conditioner outdoor unit or to F1,F2,E terminals of the
transformer;

3562

255.255.255.0

12

5. 485 communication wire connection

After finishing setting the IP address,


connect the device to a router or
transformer, the connecting way is
shown in the figure:

Fig.3.15

NOTE

Fig.3.12

As shown in the figure, enter into


Network and Internet . Click Network
and Sharing Connection to enter
Local Area Connection Properties

C. Static address settings

Fig.3.13

In the example of A step, we see the


Default Gateway: 10.46.4.1, Subnet
Mask: 255.255.255.0, thus we need to
change the IP address of this segment
as IP10.46.4.100,Subnet
255.255.255.0.

Fig.3.10

There is no
such an
address in
this LAN

Fig.3.6

Fig.3.9

cross line

If it appears Request timed out and Lost=4, it indicates our network segment
doesnt have this address. Thus, we can begin C ,static address operations.
If it appears Lost=0, it indicates our network segment has been occupied. Thus, we
process B data converter address configuration

Theres such
an address
in this LAN

Click the setting page on the top right


corner, do page settings and change
the IP address.

For detailed information about


the IP address segments, please
refer to the related information.
Due to the limited space, we
dont do Detailed explain.

CMD path: click Start menu - operation - CMD or click Start All programs Accessories - CMD to enter.
Fig.3.5

Fig.3.4

3. Data converter installation


precautions
a. Dont install it in the place where
flammable gas leaks easily.Once
flammable gas leakage occurs and
stagnate around the device, it may
result in fire.
b. Keep the device from heating
element as far as possible.
c. Dont install it in the place that is too
dirty or humid.

Power supply
terminal

Outline

1. Unpack the packing box to see if


the accessories are all in readiness.
Data converter is shown as the
following figure:

RESET

485 terminal

Qty.

The system is mainly made of the


central air-conditioning system, data
converters, Routing, cloud service and
control ends. Users can control the
air-conditioning system remotely
through terminal devices, such as
computers, mobile phones and PAD.
Connect the data converter to Ethernet,
and connect it to A bus of the central
air-conditioning or RS-485 protocol
network bus of CCM03 through RS-485
protocol interface.

This data converter is an equipment


which is based on the TCP/IP protocol
and RS-485 protocol. It provides TCP/IP
access interface to the Midea multiconnected central air-conditioner
system, and realize WEB/HTTP based
on the protocols. Users can realize
remote accesses to Midea multiconnected central air-conditioning
system efficiently and conveniently
through LAN/WAN by
WEB/HTTP/TCP/IP.

Icon description

Thank you very much for purchasing our product.


Before using your unit, please read this manual carefully and keep it for future reference.

Do not spray flammable aerosol to the wire


controller directly. Otherwise, fire may occur.

1. Product Description

2. Property loss means loss of properties and materials.

lcon

Forbid

II. System introduction of


the data converter

[Note]: 1. Harm means injury, burn and electric shock which need
long-term treatment but need no hospitalization

Delegate
installation

Please entrust the distributor or professionals to install


the unit. The installers must have the relevant know-how.
Improper installation performed by the user without perm
ission may cause fire, electric,shock, personal injury or w
ater leakage.

Users use the system through the webpage(http:// www.imdv.com.cn ) or IOS app so
that we should do the following operations

First of all, input the address of Midea air-conditioner cloud center, click registration
and enter into the registration page.
In the registration page, input your password and verification code(Note: the code
should be a 6~8-digit number). Submit after confirmation.

Subnet mask: : having found


Subnet Mask address in step
A, then input Subnet Mask:
255.255.255.0

Input the Default Gateway


address which has been
found in Step A.

After finishing
settings, click OK
to confirm.
Fig.3.17

Connect to E terminal
Connect to Y or F2 terminal
Connect to X terminal or
F1 terminal

Fig.3.18
NOTE

Fig.3.19

Note: set the IP address according


to the situation. Its only an example
above .

15

WEB page configuration

Webpage and computer configuration requirements.


WEB browsers: IE 6.0 above, Safari 4.0 above, Chrome 18.0 above, UC 8.4
above.

Operation systems: Windows/Linux/Unix/Mac/iOS etc.


Operation platforms: PC/Notebook/PAD/Smart phone (iPhone, Android etc).
Input the URL address of our cloud server(http:// www.imdv.com.cn) to log in our

Fig.3.20

cloud server. The air-conditioner will be monitored after logging in.

Fig.3.21

Take Windows XP and IE 6.0 as an example to do interface instruction. Operations


are the same in other platforms and browsers, but displays may be different. Due
to compatible problems in explaining HTML and JAVASCRIPT by browsers, we
suggest to use a higher browser version to solve some compatible problems.

17

16

18

Open the browser and input IP address of the device and enter into the webpage,
click settings on the top right corner.

Input "http://www.imdv.com.cn"on the browser, it will login the cloud services


webpage and enter the following dialog:

20

2. Master computer websites and air-conditioner browser interface instruction.

IV. Webpage instruction of the Master computer

3. Enter into the cloud center page

2. Enter into data converter WEB page configuration

19

1. Master computer websites and air-conditioner browser interface instruction.

Click the air-conditioner which is need to be controlled to control a single unit.


Click group control to control all the computers together. Shown as the following
picture:

3. Change the password


Users can change the password according to their needs.
Preserve your password properly after changing.

Mode settings:Cooling,
heating, fan only and
auto mode.

User defined name


Corresponding CCM03
Modbus address

Air flow speed settings:


high speed, middle
speed and low speed.

Subnet mask

Data module IP address

Cloud Server IP

Temp. settings: set temp.

Default gateway
Input your ID
and word

Fig.3.22
Registration successfully, please remember your personal information. Its a
personal ID, please take care of it.

from 17 C to 30C
according to your need.

Fig.3.23
After inputting your ID and code, click download settings to complete the
configuration and go back.

Fig.3.24
Log in Midea central air-conditioner cloud service center and input your ID
number and password.

21

Refresh: Refresh the webpage


All Ctrl: can set and control all the indoor units.
All off: can turn off all the indoor units.
Schedule: can set the weekly schedule function.
Rename: can rename the region name.
Add/Del Region: can add a new region or delete the region.
Add/Delete AC: can add or delete the indoor unit.
Error Table: can check the error codes
Alarms: can check the fault records.

Back: go back to the


previous page.

Fig.4.3

Lock:

can lock the


mode,setting temperature, fan speed and
remote controller.

Fig.4.2

24

23

22

Fig.4.1

NOTE
password is a 6~8 digit number.

25

26

V. iPhone app instruction

4.1 Group control function instructions

2. Login

1. Iphone app operation manual instruction


IP address is the one
set in the previous step
Port3526

ID is the registration ID
Password is the one
set when registering

Fig.5.2
Fig.4.7

Fig.4.6
Add device or location names in Name column as shown above. Input the
corresponding.Users ID and password in UserID and Pwd columns. Click
Apply to finish adding.

Fig.4.4
Input users ID, password and tick As Group User . Click Login to enter into
group user control interface.

Fig.4.5

28

Click REFRESH to
refresh the unit status

Current unit number

2. iPad app instruction Interface settings

32

31

3. iPad app instruction Area settings

VII. Android App Instructions

4. iPad app instructionTiming functions

1. The main interface

Please log in Midea central air-conditioning cloud server http://imdv.com.cn, and


Click the Android icon shown as the following to download the app.

Refresh
Display all the
air-conditioner
being connected

Setting
Timer control
panel

Click BACK to go back


to the previous menu
Check the ambient
temp

30

29

VI. iPad app instruction

iPhone control app is designed for Apple IOS users to control the central
air-conditioner system, Under the App store to search "Midea", you can find the
software called "Midea MDV", and you can download it for free.

After logging in, click refresh to check the number of units, actual temp. of each unit and the
operation conditions directly. You can also group control operation modes of units or start
up/shut down the units. For controlling a single unit, just click it directly. Users can change
the names of units according to their needs.

After connecting the data converter, monitor or timing a single or multiple units in the
air-conditioning system. See the iPhone interface in the figure.

Click the "Edit" button on the left bottom can set it.

27

3. Single air-conditioning control interface

Shown as the figure above, click the device name to control air-conditioners in
the region

Fig.5.1

Ambient temp.

Set the temp.


Additive area

Selecting areas of
controlling the current
operation mode

Fan speed adjustment


area

Error information
Lighting up when
error occurs

Power on/off key to


the current A/C

Fig.5.3

Control page

Additive area

Error

Click system setting icon

As shown in the picture, click the area where needs to add an indoor unit and

Click the timing icon on the top right bottom to enter into the timing setting interface.
Timing interface can set multi-segment time to control the air-conditioner. Timing
can be added in All or in Areas. Note: time settings cant conflict with modes.

click Edit. Click to enter indoor unit adding status. Input the indoor unit number in
Fig.6.1

this area, and click

Conference hall to Huiyi

34

35

After installing the app input the applied users ID and your
password, then click log in to Enter.

Fig.7.1

users ID and password and confirm.

38

37

36

Click Settings to enter into configuration interface, click Connection 1. Input the
Air-conditioner zone

to complete adding; Except for adding names in areas, we

can also deleting or changing the area names. As shown in the picture, we change

App logging in refers to iPhone control app. The control panel is shown in the figure

33

Fig.6.4

. Change the IP address and log-in password of the

data converter. Auto log in can be set.

Power on/off key


to the current
air-conditioner

Unit status display area

Fig.6.5

Fig.6.2

After configuration and refreshment, the screen will show the connected

Version:MD13IU-005CW

air-conditioner,Click the air-conditioner which needs to be controlled to enter into


the controlling interface,Control on/off status, temperature and mode for a certain
air-conditioner.

Add a new
air-conditioner zone

Group control all-off

Group control all on


Settings
Fig.7.5
Fig.7.2

Fig.7.3
Fig.7.4

202055100964