Está en la página 1de 1

LIMITE DE PLANO

4"AA1-2RF

TIE IN
40

V-01

1484
B

BOP +298.200

TIE IN
21

4"AA1-5R
DRENAJE
3/4"CA1-2S
BOP +301.014

0.21%

S-17

PROGRESIVA O: 25137 /CONT. EN VENTANA 2

6"-G-106-AA1

S-18

6"AA1-2RF
CSO
3/4"CA1-2S
BR 6"

BOP +300.993
S-20

3/4"CA1-2S

5431
14042

6"-G-106-AA1

TIE IN
38

S-22

S-23
6"-G-106-AA1

3635

6420

NP + 298.000

0.21%

S-24

7000

BOP +300.919

BOP +300.933

P.F.

BOP +300.948

S-21

BOP +300.963

BOP +300.986

BOP +300.976

CAJA

3431

S-015

S-25

BRIDA CIEGA.
6"-150#

TIE IN
22

S-26

GARITA

PSV
151

TIE-IN
15

BASE

6"AA1-2RF

TIE IN
37

575

6"-G-111-AA1

BOP +303.505

1113

5413
S-19

628

DETALLE J

721

4"AA1-2RF

BOP +301.006

0.21%

4"-TEMPORAL

BOP +301.005

HIDRANTE

PROGRESIVA O: 69968 /CONT. EN DWG: 57D303-SYP-54-202

3257

6"-G-106-AA1

BRIDA CIEGA.
6"-150#

6"-G-106-AA1

6860

6810

6932

LNEA DE GAS A TEA EXISTENTE

LIMITE DE PLANO
PROGRESIVA N: 15700/ CONT. EN DWG: 57D303-SYP-54-204

LINEAS NUEVAS
LINEAS NUEVAS ENTERRADAS

QUIMICOS

0.21%

1880

3700

R.C. 10"x6"

6"AA1-2RF

1 1/2"-GP-102-AA1

S-36

0.21%

S-38

S-37

0.21%
S-40

S-41

5700

5000

5300

6000

4000

4000

57D303-SYP-54-205 SECTOR FLARE

NOTA 4

321

R.C.1 1/2"x1"

R.C.1 1/2"x1"

100

PLATEA 2000x1700

3/4 "CA1-2S

DETALLE J

CORTE L-L

BLEED RING

PSV
152

6"AA1-2RF

TIE IN
30

6" LINEA EXISTENTE

BLEED RING
3/4" CA1-2S

TIE IN
29

S-34

CL+ 299.225

3/4" CA1-2S

PSV
V-152

BOP+298.482
6" AA1-7R

PSV

N.P.+298.00

152

TIE IN
24

S-33

CORTE E-E

6"AA1-2RF

6" LINEA EXISTENTE

LIMITE DE PLANO

1- TODAS LAS DIMENSIONES ESTAN EN MM Y LAS COORDENADAS EN M.


2- LAS COORDENADAS 0,0,0 INDICADAS, CORRESPONDES A LAS COORDENADAS UTM: E=323199.06 ; N=10001179.10
3- CODIGO ANTERIOR 57PRD001-SYP-54-203
4- DATA SHEET REFERIRSE AL ENVIADO POR EL PROVEDOR.
5- CAMBIOS POR MEJORAMIENTO EN EL SISTEMA DE VENTEOS.
2

6" AA1-7R

CORTE H-H
E

BOP +298.400

BOP +301.171
S-34

1027

484

145

145
321

10"-G-108-AA1

6000
2550

BOP +300.806

1661

57D303-SYP-54-203 SECTOR TENDIDO DE LINEAS (PARTE 1)


57D303-SYP-54-204 SECTOR KOD
57D303-SYP-54-205 SECTOR TENDIDO DE LINEAS (PARTE 2)

457

6660

0.21%
10"-G-112-AA1

PANEL DE
CONTROL
S-39

S-42
BOP +300.812

10"-G-112-AA1

TIE IN
25

287

S-35

P.F.

BOP +300.824

R.E. 10"x6"

BOP +300.845

BOP +300.832

S-32

S-31

NP + 298.000

57D303-SYP-54-203 SECTOR BOTA DE GAS

741

TIE IN
24

6960

S-43

57D303-SYP-54-202 SECTOR SEPARADORES

4"AA1-2RF

2822

2200

2309

BOP +301.171

BOP +300.856

4726
10"G-110-AA1

BOP +300.867

CORTE F-F

PLATEA 2000x1700

BOP +300.879

R.E. 10"x6"

N.P. NIVEL DE PISO


N.B. NIVEL DE BASE
BR. BLEED RING DIMENSION
P.F. PUNTO FIJO

10"G-110-AA1

TIE IN
25

BOP +300.889

CORTE G-G

BOP +300.794
S-44

BOP +300.904

BOP +300.860

PROGRESIVA O: 25137 /CONT. EN VENTANA 1

S-015

SUMIDERO

2645

TIE-IN
15

BOMBAS DE
TRANSFERENCIA

SUMIDERO

3/4"CA1-2S
BR 4"

PROGRESIVA E: 19694 /CONT. EN DWG: 57D303-SYP-54-205

BOP +300.782
S-45

CASETA
BR 6"
4"AA1-2RF
CSO

LINEAS EXISTENTES A DESMONTAR

REUBICADA

570

6"AA1-2RF
CSO

BOP +300.816

3/4"CA1-2S

LINEAS EXISTENTES ENTERRADAS

1798

PSV
151

Sertecpet