Está en la página 1de 13

Customer : AXM

Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

** ON A/C ALL
TASK 24-00-00-810-818-A
Computer Reset
1.

Possible Causes

2.

Fault Confirmation
Subtask 24-00-00-710-059-A
A.

Test
(1) Not applicable

3.

Fault Isolation
Subtask 24-00-00-865-051-A
A.

Table of the circuit breakers used in this procedure:


PANEL
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU
49VU

DESIGNATION
FUEL/FQI/CHAN/1
ENGINE/2/FIRE DET/LOOP B
ENGINE/1/FIRE DET/LOOP A
ENGINE/2/FADEC A/AND EIU 2
ENGINE/1/FADEC A/AND EIU 1
FLIGHT CONTROLS/ELAC1/NORM/
SPLY
FLIGHT CONTROLS/FCDC1/SPLY
FLIGHT CONTROLS/SEC1/NORM/SPLY
AUTO FLT/FCU/1
AUTO FLT/FAC1/28VDC
AUTO FLT/FAC1/26VAC
AUTO FLT/FMGC/1
AUTO FLT/MCDU/1
L/G/LGCIU/SYS1/NORM
AIR COND/CAB/PRESS/CTL1
AIR COND/TEMP CTL/SYS 1 CHAN
B/28VDC
EIS/DMC1/SPLY
FWS/FWC1/SPLY
NAV/MMR/1
COM/CIDS/DIR ESS/2
COM/CIDS/DIR ESS/1
COM/CIDS/FLT ATTND PNL/ESS

FIN
1QT
8WD2
7WD1
2KS2
2KS1
15CE1

A13
A07
A06
A05
A04
B11

LOCATION

20CE1
21CE1
9CA1
5CC1
14CC1
10CA1
11CA1
1GA
1HL
52HH

B10
B08
B05
B04
B03
B02
B01
C09
D09
D08

10WT1
3WW
42RT1
157RH
150RH
171RH

E11
F01
G12
G02
G01
H01

** ON A/C 001-050, 102-105, 108-108, 110-121, 123-208, 212-212, 501-700


121VU
COM NAV/T2CAS
104SG
K10
** ON A/C 001-050, 102-105, 108-108, 110-121, 123-300, 501-701, 703-703, 707-708, 710-710, 715-750
121VU
ENGINE/ENG1 AND 2/EVMU
1EV
R44
** ON A/C ALL
121VU

COM NAV/RAD ALTM/2

1SA2

K12

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 1 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

PANEL
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU
121VU

DESIGNATION
COM NAV/RAD ALTM/1
APU/FIRE AND OVHT/DET/LOOP B
APU/FIRE AND OVHT/DET/LOOP A
FUEL/FQI/CHANNEL/1 AND 2
ATSU 1
ATSU 1/SWTG
COM NAV/MMR/2
HYDRAULIC/BRAKING AND STEERING/SYS2/SPLY
HYDRAULIC/BRAKING AND STEERING/SYS2/CTL
HYDRAULIC/BRAKING AND STEERING/SYS1/CTL
HYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY
FUEL/FQI/CHAN/2
AUTO FLT/FCU/2
AUTO FLT/FAC2/28VDC
AUTO FLT/FAC2/26VAC
AUTO FLT/FMGC/2
COM NAV/CIDS/DIR NORM/2
COM NAV/CIDS/DIR NORM/1
AUTO FLT/MCDU/2
ENGINE/ENG2/FADEC B/AND EIU 2
ENGINE/ENG2/FIRE DET/LOOP A
ENGINE/ENG1/FIRE DET/LOOP B
HYDRAULIC/LGCIU/SYS2
HYDRAULIC/LGCIU/SYS1/GRND SPLY
FLIGHT CONTROLS/FCDC2/SPLY
FLIGHT CONTROLS/SEC3/SPLY
FLIGHT CONTROLS/SEC2/SPLY
COM/FAP1/NORM
EIS/DMC3/SPLY
EIS/DMC2/SPLY
EIS/FWC2/SPLY
ENGINE/ENG1/FADEC B/AND EIU 1
FLIGHT CONTROLS/ELAC2/NORM/
SPLY

FIN
1SA1
2WG
1WG
8QT
3TX1
5TX1
42RT2
4GG

K11
L44
L43
L26
L16
L15
L07
M36

LOCATION

3GG

M35

1GG

M34

2GG

M33

2QT
9CA2
5CC2
14CC2
10CA2
156RH
151RH
11CA2
4KS2
7WD2
8WD1
2GA
52GA
20CE2
21CE3
21CE2
170RH
10WT3
10WT2
2WW
4KS1
15CE2

M27
M21
M19
M18
M17
M06
M05
N20
Q40
Q39
Q38
Q35
Q34
Q20
Q19
Q18
Q14
Q09
Q08
Q07
R41
R20

** ON A/C 209-211, 213-300, 701-701, 703-703, 707-708, 710-710, 715-750, 801-850


121VU
T/TISS
2004SG K07
** ON A/C ALL
122VU
122VU
122VU
122VU

AIR COND/TEMP CTL SYS 2/CHAN


A/115VAC
AIR COND/TEMP CTL SYS 2/CHAN
A/28VDC
ANTI ICE/WHC/2
AIR COND/TEMP CTL SYS 1/CHAN
A/115VAC

53HH

W22

55HH

W21

5DG2
49HH

W13
X22

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 2 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

PANEL
122VU
122VU
122VU
122VU
122VU
122VU
122VU

DESIGNATION
AIR COND/TEMP CTL SYS 1/CHAN
A/28VDC
ANTI ICE/WHC/1
AIR COND/CAB PRESS/CTL/2
AIR COND/TEMP CTL SYS 2/CHAN
B/28VDC
AIR COND/TEMP CTL SYS 2/CHAN
B/115VAC
AIR COND/TEMP CTL SYS 1/CHAN
B/115VAC
AIR COND/AVNCS/VENT/MONG

FIN
51HH

X21

LOCATION

5DG1
2HL
56HH

X13
Y22
Y21

54HH

Y20

50HH

Y18

3HQ

Y17

** ON A/C 001-050, 102-105, 108-108, 110-121, 123-300, 501-701, 703-703, 707-708, 710-710, 715-750
2001VU
VACUUM TOILET SYSTEM/VACUUM
35MG
A06
SYS
** ON A/C ALL
Subtask 24-00-00-810-069-A
B.

Computer reset procedure


NOTE: This reset procedure is used when a computer does not operate correctly.
NOTE: The line maintenance personnel can use it a first time to avoid a computer replacement (a reset
must be done for the applicable computer as indicated in the Computer Reset Table). But, if there
is more than one reset for each flight cycle for a given computer, it is necessary to do the specific troubleshooting procedure for the applicable system. If after a reset, the computer operates correctly, no more action is necessary.
(1) To do computer reset:
(a) Set the related normal cockpit control to OFF, or open the related circuit breaker as specified in
the reset procedure.
(b) Wait 3 seconds if a normal cockpit control is used, or 5 seconds if a circuit breaker is used
(unless a different time is indicated).
(c) Set the related normal cockpit control to ON, or close the related circuit breaker.
(d) Wait 3 seconds for the end of the reset.

Subtask 24-00-00-810-075-E
C.

Air Conditioning
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
21
CAB PR SYS 1(2) FAULT

COMPUTER
CABIN
PRESSURE
CONTROLLER
(CPC) 1(2)

21

CARGO

AIR FWD (AFT) CRG VENT

RESET PROCEDURE
For CPC 1:
- On panel 49VU, open the
circuit breaker 1HL.
FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
On panel 49VU:

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 3 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION
FAULT

COMPUTER
VENTILATION
CONTROLLER

21

VENT AVNCS SYS FAULT

21

AIR PACK 1(2) REGUL FAULT

AVIONICS
EQUIPMENT
VENTILATION
COMPUTER
AIR COND
SYSTEM
CONTROLLER
(ACSC) 1(2)

21

COND AFT CRG HEAT FAULT

AFT CARGO
HEAT
CONTROLLER

RESET PROCEDURE
- Open the circuit breaker 31HN
After five seconds, close the
circuit breaker.
On panel 122VU:
- Open the circuit breaker 3HQ.
After five seconds, close the
circuit breaker.
For the ACSC 1:
- On panel 122VU, open
the circuit breaker 49HH,
circuit breaker 50HH
and circuit breaker 51HH.
- On panel 49VU, open
the circuit breaker 52HH.
Then close the circuit breakers.
For the ACSC2:
- On panel 122VU, open
the circuit breaker 53HH,
circuit breaker 54HH,
circuit breaker 55HH and
circuit breaker 56HH.
Then close the circuit breakers.
On panel 49VU:
- Open the circuit breaker 31HN.
- After five seconds, close
the circuit breaker.

Subtask 24-00-00-810-076-A
D.

Auto Flight
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
22
AUTO FLT YAW DAMPER 1(2)
FAULT

COMPUTER
FAC1(2)

22

WINDSHEAR DET FAULT or


REAC W/S DET FAULT

FAC 1+2

22

AUTO FLT FCU 1(2) FAULT

FCU

RESET PROCEDURE
Open these C/Bs with the
Yellow and Green hydraulic
systems pressurized:
- for the FAC 1: on the
panel 49VU, C/B 5CC1
- for the FAC 2: on the
panel 121VU, C/B 5CC2
Then close the C/Bs after 10
seconds.
Open then close the C/Bs in
this the order:
- on the panel 49VU, C/B
5CC1 and C/B 14CC1
- on the panel 121VU, C/B
5CC2 and C/B 14CC2.
For the FCU1:
- on the panel 49VU, open
the C/B 9CA1.
For the FCU2:

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 4 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION

COMPUTER

22

One MCDU locked or blank

MCDU

22

FMGC malfunction
Both MCDUs locked or blank

FMGC
FMGC

RESET PROCEDURE
- on the panel 121VU, open
the C/B 9CA2.
Close the C/B after 5
seconds.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful).
If the fault continues, open
again the two C/Bs 9CA1
on 49VU and 9CA2 on 121VU.
Close the C/Bs after 7 min,
with an interval less than
5 sec between side 1 and
side 2.
At least 30 sec are necessary
until the end of the FCU1
and FCU2 safety test.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful)
If the fault continues, end
of procedure (reset
unsuccessful).
Open then close the C/B of
the defective MCDU after 10
seconds:
- For the MCDU1: on the
panel 121VU or panel 49VU,
C/B 11CA1.
- For the MCDU2: on the
panel 121VU, C/B 11CA2.
- For the MCDU3: on the
panel 121VU, C/B 11CA3.
On the panel 121VU or 49VU:
- open the FMGC 1 C/B 10CA1
and close it after 10
seconds.
When initiated engine
stopped
(aircraft in maintenance
configuration), the reset
will be followed by a
power-up test sequence of
around 90 seconds. During
this test sequence,
the system is unavailable.
If there is no reset of the

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 5 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION

COMPUTER

RESET PROCEDURE
FMGC 1, do a reset of the
FMGC 2 on the panel 121VU:
- open the C/B 10CA2 and
close it after 10 seconds.

ATA
SYSTEM MALFUNCTION
23
COM CIDS 1+2 FAULT

COMPUTER
CIDS

23

Uncommanded EVAC horn


actuation

CIDS

23

Frozen RMP

RMP

23

Frozen FAP

FAP

RESET PROCEDURE
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
Press the EVAC/HORN SHUT
OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
Open the C/Bs in this order:
On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
the C/Bs in this order:
170RH, 171RH

Subtask 24-00-00-810-077-D
E.

Communications
(1) Computer Reset Table

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 6 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION

COMPUTER

RESET PROCEDURE
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.

COMPUTER
GAPCU

RESET PROCEDURE
If at least one power source
(IDG 1 or IDG 2, APU GEN or
batteries) is connected to
the electrical network of
the aircraft:
- On the ELEC control panel
35VU:
. Push and release the
EXT PWR pushbutton
switch.
If no power source is
connected to the electrical
network of the aircraft:
- On the ELEC control panel
35VU:
. Push the BAT 1 and BAT 2
pushbutton switches
(the OFF legend goes
off).

ATA
SYSTEM MALFUNCTION
27
F/CTL ELAC 1(2) FAULT
F/CTL ALTN LAW FAULT

COMPUTER
ELAC

27

ELAC or SEC

RESET PROCEDURE
Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
- Set the ELAC pushbutton
switch to OFF, then to ON.
Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
Open, then close the C/B of

Subtask 24-00-00-810-088-A
F.

Electrical Power
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
24
GPU cannot be connected
to the aircraft

Subtask 24-00-00-810-079-A
G. Flight Controls
(1) Computer Reset Table

ELAC or SEC malfunction

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 7 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

27

SYSTEM MALFUNCTION

E/W FCDC1(2) FAULT

COMPUTER

FCDC

RESET PROCEDURE
the defective ELAC or SEC.
For the ELAC 1(2):
- On the panel 49VU, C/B
15CE1.
- On the panel 121VU, C/B
15CE2.
For the SEC 1(2)(3):
- On the panel 49VU, C/B
21CE1.
- On the panel 121VU, C/B
21CE2 or 21CE3.
On the panel 49VU:
- For FCDC1, open the C/B
20CE1.
- For FCDC2, open the C/B
20CE2.
- After 5 seconds, close
the C/Bs.

Subtask 24-00-00-810-089-A
H.

Fuel
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
28
Loss of fuel quantity
indication or,
Simultaneous triggering
of FUEL L XFR VALVE
CLOSED and FUEL R XFR
VALVE CLOSED, although
FUEL SD indicates no
anomaly.

COMPUTER
FQIC

RESET PROCEDURE
On the overhead circuit
breaker panel 49VU:
- Open the C/B 1QT.
On the rear circuit
breaker panel 121VU:
- Open the C/Bs 2QT and 8QT.
After 5 seconds, close the
three C/B's.

COMPUTER
WHC

RESET PROCEDURE
Open then close the C/B of
the defective WHC.
For the WHC1:
- on the panel 122VU, C/B
5DG1.
For the WHC2:
- on the panel 122VU, C/B
5DG2.

Subtask 24-00-00-810-080-A
J.

Ice and Rain Protection


(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
30
ANTI ICE
L(R)/WINSHIELD (WINDOW)

Subtask 24-00-00-810-081-A
K.

Indicating/Recording Systems

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 8 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

(1) Computer Reset Table


ATA
SYSTEM MALFUNCTION
31
FWS FWC 1(2) FAULT

COMPUTER
FWC

31

EIS DMC 1(2)(3) FAULT

DMC

31

CAPT PFD DU malfunction

CAPT PFD DU

31

CAPT ND DU malfunction

CAPT ND DU

31

F/O PFD DU malfunction

F/O PFD DU

RESET PROCEDURE
Open then close the C/B of
the defective FWC
For the FWC1:
- on the panel 49VU, C/B 3WW
For the FWC2:
- on the panel 121VU, C/B
2WW.
Wait 50 seconds after you
close the C/Bs.
Open then close the
circuit breaker of
the defective DMC
For the DMC1:
- on the overhead C/B panel
49VU, the circuit breaker
10WT1.
For the DMC2:
- on the rear C/B panel
121VU, the circuit breaker
10WT2.
For the DMC3:
- on the rear C/B panel
121VU, the circuit breaker
10WT3.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the OFF position to
the BRT position.
On the F/O lightning/loud
speaker control-panel 500VU,

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 9 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION

COMPUTER

31

F/O ND DU malfunction

F/O ND DU

31

EWD malfunction

EWD

31

SD malfunction

SD

RESET PROCEDURE
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the OFF position to
the BRT position.
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
BRT + position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
OFF position to the BRT +
position.
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
BRT position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
OFF position to the BRT
position.

Subtask 24-00-00-810-082-A
L.

Landing Gear
(1) Computer Reset Table

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 10 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA
SYSTEM MALFUNCTION
32
Braking malfunction

COMPUTER
BSCU

32

LGCIU 1(2)

L/G LGCIU 1(2) FAULT

RESET PROCEDURE
On the panel 121VU:
- open the C/Bs 1GG, 2GG,
3GG and 4GG
- after 5 seconds, close
the CB's
For the LGCIU 1:
- on the panel 121VU, open
the C/B 52GA then on 49VU,
C/B 1GA. After 15 seconds,
close the C/B 1GA and C/B
52GA
For the LGCIU 2:
- on the panel 121VU, open
the C/B 2GA. After 15
seconds, close the C/B 2GA

** ON A/C 001-050, 102-105, 108-108, 110-121, 123-208, 212-212, 501-700


Subtask 24-00-00-810-083-B
M. Navigation
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
34
NAV MMR 1(2) FAULT

COMPUTER
MMR1(2)

34

NAV TCAS FAULT

T2CAS

34

NAV GPWS FAULT


NAV GPWS TERR DET FAULT

T2CAS

34

NAV GPS 1(2) FAULT

GPSSU

34

NAV RA 1(2) FAULT

XCVR-RA

RESET PROCEDURE
For the MMR 1:
- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.
On the panel 121VU:
- Open the C/B 104SG.
- After 5 seconds, close
the C/B.
On the panel 121VU:
- Open the C/B 104SG.
- After 5 seconds, close
the C/B.
On the panel 121VU:
- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.
On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 11 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

ATA

SYSTEM MALFUNCTION

COMPUTER

RESET PROCEDURE
C/B 1SA2.
- After 5 seconds, close
the C/Bs.

** ON A/C 209-211, 213-300, 701-701, 703-703, 707-708, 710-710, 715-750, 801-850


Subtask 24-00-00-810-083-D
M. Navigation
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
34
NAV MMR 1(2) FAULT

COMPUTER
MMR1(2)

34

NAV TCAS FAULT

T/TISS

34

NAV GPWS FAULT


NAV GPWS TERR DET FAULT

T/TISS

34

NAV ATC/XPDR FAULT

T/TISS

34

NAV GPS 1(2) FAULT

GPSSU

34

NAV RA 1(2) FAULT

XCVR-RA

RESET PROCEDURE
For the MMR 1:
- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
On the panel 121VU:
- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.
On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.

** ON A/C ALL
Subtask 24-00-00-810-085-A

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 12 of 13

Customer : AXM
Manual : TSM
Type : A318/A319/A320/A321
Selected applicability : 133-133, 228-228
Rev. Date : May 01, 2016
24-00-00-810-818-A - Computer Reset

N.

Information Systems
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
46
ATSU malfunction

COMPUTER
ATSU

RESET PROCEDURE
On the rear circuit
breaker panel 121VU:
- Open the C/Bs in this
order: 3TX1 and 5TX1.
- After 5 seconds, close
the C/Bs in this order:
5TX1 and 3TX1.

ATA
SYSTEM MALFUNCTION
70
ENG 1(2) IGN A + B FAULT

COMPUTER
FADEC and
EIU

70

FADEC

RESET PROCEDURE
On the overhead circuit-breaker panel 49VU and rear circuit-breaker panel 121VU, open then close the circuit
breakers of the defective FADEC.
For engine 1:
2KS1 and 4KS1.
For engine 2:
2KS2 and 4KS2.
On the overhead circuit-breaker panel 49VU and rear circuit-breaker panel 121VU, open then close the circuit
breakers of the defective FADEC.
For engine 1:
2KS1 and 4KS1.
For engine 2:
2KS2 and 4KS2.

Subtask 24-00-00-810-086-A
P.

Engine
(1) Computer Reset Table

ENG 1(2) FADEC A(B) FAULT

Subtask 24-00-00-810-090-A
Q. Engine Indicating
(1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
77
Loss of N1VIB and N2VIB
indications for ENG1(2)
in ECAM SD

COMPUTER
EVMU

RESET PROCEDURE
On the panel 121VU:
- Open the C/B 2EV.
- After 5 seconds, close the
C/B.

End of document

Print Date: May 08, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 13 of 13

También podría gustarte