Está en la página 1de 2

MICRO SERIES

Water Temperature
Control Units

COMPACT SIZE PROVIDES


BIG PERFORMANCE
All Micro Series water temperature control units have an
operating leaving water temperature range of 32F up to
a maximum of 250F (0C to 121C).

Options

Off-the-shelf 1/16th DIN microprocessor based


PID controller
Non-ferrous construction
Easily removable panels for quick access to
internal components
Incoloy immersion heater with IEC contactors
Pressure switch set at 16 psig
NEMA 1 electrical enclosure
250F (121C) maximum operating temperature
Motor Circuit Protector
Independent safety thermostat
1 year parts and labor warranty at the factory
3 year controller warranty
3/4 on all connections

Casters; available in lieu of rubber feet


Manual bypass
Pressure regulator/relief valve for water supply
(shipped loose)
Y-Strainer (shipped loose)
Quick cool switch
Auto system water purge (mold purge),
shipped loose
General fault audible/visual alarms
Remote Start/stop
Communications RS232, RS485, RS485-SPI*
Ten-foot power cord; no plug, shipped loose
Rotary, thru-the-door disconnect switch
UL/cUL-listed electrical subpanel
Remote controller w/enclosure and 20 ft.
cable, shipped loose
Operating voltages: 208/3/60, 230/3/60,
400/3/50, 575/3/60
Pressure gauges (Shipped loose, to be mounted
on back of unit)

*RS485SPI requires a different controller

Temperature Control Units

Features

MICRO SERIES

Water Temperature
Control Units

SPECIFICATIONS
Model Number
460
230
Micro

Pump,
HP (kW)

Flow,
gpm (lpm)

Pressure,
psig (bar)

Height,
in. (mm)

Width,
in. (mm)

Depth,
in. (mm)

Ship. weight,
lbs. (kg)

0.5 (0.37)

15 (57)

20 (138)

17.5 (44)

9.5 (24)

23 (58)

110 (50)

0.75 (0.56)

20 (76)

23 (159)

17.5 (44)

9.5 (24)

23 (58)

110 (50)

DIMENSIONS
To Process
Cooling Water Out
17.5

From Process
Cooling Water In

23

9.5

PART NUMBERING SCHEME

M__-_-_-_-__

50 - 0.5 hp
75 - 0.75 hp

Temperature Control Units

3 - 3 kW
6 - 6 kW
9 - 9 kW

1
2
3
4
5

208/3/60
230/3/60
400/3/50
460/3/60
575/3/60

VAC
VAC
VAC
VAC
VAC
2 - 250F

MB - Manual bypass
PR - Pressure regulator
YS - Y-Strainer
QC - Quick cool switch
AP - Auto system water purge
AV - Audible/visual alarm
RS - Remote start/stop
R2 - RS232 communications
R4 - RS485 communications
RP - RS485-SPI communications
DS - Disconnect switch
PC - Power cord
RC - Remote controller
UL - U.L./cUL listed subpanel
CS - Casters in lieu of rubber feet
PG - Pressure gauge

Example:
M75-9-4-2-AV-QC: Micro w/ 3/4 hp pump, 9 kW heater, 460 VAC, 250F maximum
operating temperature, Audible/Visual Alarm, and Quick Cool Switch

Specifications, appearances and dimensions


are subject to change without notice. 5.12