Está en la página 1de 7

Profis Anchor 2.5.

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

1
1/13/2016

Specifier's comments:

1 Input data
Anchor type and diameter:

HIT-HY 270 + HIT-V (8.8)

Effective embedment depth:

M8, HIT-SC 16x85+16x85


hef,opti = 145 mm (hef,limit = 145 mm)

Material:

8.8

Evaluation Service Report:

ETA-13/1036

Issued I Valid:

12/15/2014 | 12/15/2019

Proof:

Design method ETAG 029, Annex C

Stand-off installation:

eb = 0 mm (no stand-off); t = 4 mm

Anchor plate:

lx x ly x t = 40 mm x 40 mm x 4 mm; (Recommended plate thickness: not calculated)

Profile:

no profile

Base material:

Brick layout: Double Stretcher; Brick: Solid Vbn, 2DF, f=6 (solid brick), Normal weight concrete, L x W x H:
240 mm x 115 mm x 113 mm;
fb,v = 6.00 N/mm2; Ewall = 1577.31 N/mm2
Mortar: M2,5 - M9; Vertical joints filled: YES; vertical: 5 mm; horizontal: 5 mm

Plaster

Eplaster = 1000.00 N/mm2

Installation/Use:

Installation condition: Dry; Use condition: Dry;


Cleaning: compressed air
Temp. short/long: 80/50 C

Geometry [mm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

1/13/2016

Geometry [mm] & Loading [kN, kNm]

2 Load case/Resulting anchor forces


Load case: Design loads
y
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Tension force
Shear force
Anchor
1
0.190
0.694
max. compressive strain:
- []
max. compressive stress:
- [N/mm2]
resulting tension force in (x/y)=(0/0):
0.190 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Shear force x
0.070

Shear force y
-0.690
Tension

x1

3 Tension load (ETAG 029 Annex C, Section C.5.2.1)


Load [kN]
0.190

Capacity [kN]
19.333

Utilization bN [%]
1

Status
OK

Pullout Strength*

0.190

0.750

26

OK

Brick breakout**

0.190

0.750

26

OK

Pullout of one brick**

0.190

55.428

OK

Steel Strength*

* anchor having the highest loading

**anchor group (anchors in tension)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

3.1 Steel Strength


NRk,s [kN]
29.000

gM,s
1.500

NRd,s [kN]
19.333

NSd [kN]
0.190

aj
0.750

gM,m
2.500

NRd,p [kN]
0.750

NSd [kN]
0.190

s|| [mm]
0

s^ [mm]
0

scr,|| [mm]
240

scr,^ [mm]
113

c [mm]
400

ccr [mm]
115

NRk,b [kN]
2.500

aj
0.750

ag,N
1.000

gM,m
2.500

NRd,b [kN]
0.750

NSd [kN]
0.190

AHact [mm2]
55200

AVact [mm2]
25990

fvko [N/mm2]
0.15

2
sd [N/mm ]
6.00

NRk,pb [kN]
138.569

gM,m
2.500

NRd,pb [kN]
55.428

NSd [kN]
0.190

3.2 Pullout Strength


NRk,p [kN]
2.500
3.3 Brick breakout

3.4 Pullout of one brick

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
1/13/2016

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

1/13/2016

4 Shear load (ETAG 029 Annex C, Section C.5.2.2)


Load [kN]
N/A

Capacity [kN]
N/A

Utilization bV [%]
N/A

Status
N/A

Steel failure (with lever arm)*

0.694

1.132

62

OK

Local brick failure**

0.694

1.200

58

OK

Brick edge failure in direction x+**

0.694

17.300

OK

0.070

109.296

OK

Steel Strength (without lever arm)*

Pushing out of one brick in direction x+**


* anchor having the highest loading

**anchor group (relevant anchors)

4.1 Steel failure (with lever arm)


l [mm]
21

aM
1.00

NSd / NRd,s
0.010

1 - NSd / NRd,s
0.990

M0Rk [kNm]
0.030

VM
Rk,s = aM * MRk,s / l [kN]
1.415

MRk,s = M0Rk,s (1 - NSd/NRd,s) [kNm]


0.030

gMs,b,V
1.250

VM
Rd,s [kN]
1.132

VSd [kN]
0.694

4.2 Local brick failure


s|| [mm]
0

s^ [mm]
0

scr,|| [mm]
240

scr,^ [mm]
113

c [mm]
400

ccr [mm]
115

ag,V
1.000

aj
0.750

VRk,b [kN]
4.000

gM,m
2.500

VRd,b [kN]
1.200

VSd [kN]
0.694

4.3 Brick edge failure in direction x+


k
0.44

dnom [mm]
8

hef [mm]
145

fb,v [N/mm2]
6.00

c1 [mm]
400

VRk,c [kN]
43.249

ag,V
1.000

gM,m
2.500

VRd,c [kN]
17.300

VSd [kN]
0.694

4.4 Pushing out of one brick in direction x+


AHact [mm2]
110400

fvko [N/mm2]
0.15

2
sd [N/mm ]
6.00

VRk,pb [kN]
273.240

gM,m
2.500

VRd,pb [kN]
109.296

VSd [kN]
0.070

5 Combined tension and shear loads (ETAG 029 Annex C, Section C.5.2.3)
bN
0.253

bV
0.613

a
1.000

(bN + bV) / 1.2 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Utilization bN,V [%]


73

Status
OK

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

5
1/13/2016

6 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Only the local load transfer from the anchor(s) to the wall is considered, a further load transfer in the wall is not covered by PROFIS!
Wall is assumed as being perfectly aligned vertically checking required(!): Noncompliance can lead to significantly different distribution of
forces and higher tension loads than those calculated by PROFIS. Masonry wall must not have any damages (neither visible nor not visible)!
While installation, the positioning of the anchors needs to be maintained as in the design phase i.e. either relative to the brick or relative to the
mortar joints.
The effect of the joints on the compressive stress distribution on the plate / bricks was not taken into consideration.
If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at this
position or the area should be assessed and reinforced. Hilti recommends the anchoring in masonry always with sieve sleeve. Anchors can only
be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void.
The accessories and installation remarks listed on this report are for the information of the user only. In any case, the instructions for use
provided with the product have to be followed to ensure a proper installation.
The compliance with current standards (e.g. ETAG 029) is the responsibility of the user.
The Youngs modulus of the wall Ewall (not plastered!) is determined in accordance to EN 1996-1-1:2012
Drilling method (hammer, rotary) to be in accordance with the approval!
Masonry needs to be built in a regular way in accordance with state-of the art guidelines!
Please note that, for ETA approved masonry units, the resistance and parameters are only valid for that particular brick (hollow/solid) or for bricks
of the same base material with larger size and larger compressive strength (solid), according to ETAG 029.
A default value of Eplaster = 1000.00 was assumed.

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

6
1/13/2016

7 Installation data
Anchor plate, steel: Profile: no profile; 0 x 0 x 0 mm
Hole diameter in the fixture: df = 17 mm
Plate thickness (input): 4 mm
Recommended plate thickness: not calculated
Cleaning: compressed air

Anchor type and diameter:


HIT-HY 270 + HIT-V (8.8) M8, HIT-SC 16x85+16x85
Installation torque: 0.003 kNm
Hole diameter in the base material: 16 mm
Hole depth in the base material: 165 mm
Minimum thickness of the base material: 215 mm
y

20

20

20

20

20

20

Coordinates Anchor mm
Anchor
1

x
0

y
0

c-x
500

c+x
400

c-y
1000

c+y
1000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

20

20

Profis Anchor 2.5.0

www.hilti.co.uk
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

7
1/13/2016

8 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan